• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 133
  • 84
  • 8
  • 8
  • 7
  • 4
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 290
  • 290
  • 290
  • 279
  • 135
  • 134
  • 129
  • 115
  • 38
  • 37
  • 28
  • 25
  • 25
  • 23
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Caracterização de imagens de microtomografia de raios X baseada em descritores de textura / Characterization of images from X-ray microtomography based texture descriptors

Sandro Roberto Fernandes 27 April 2012 (has links)
A microtomografia computadorizada (computed microtomography - μCT) permite uma análise não destrutiva de amostras, além de possibilitar sua reutilização. A μCT permite também a reconstrução de objetos tridimensionais a partir de suas seções transversais que são obtidas interceptando a amostra através de planos paralelos. Equipamentos de μCT oferecem ao usuário diversas opções de configurações que alteram a qualidade das imagens obtidas afetando, dessa forma, o resultado esperado. Nesta tese foi realizada a caracterização e análise de imagens de μCT geradas pelo microtomógrafo SkyScan1174 Compact Micro-CT. A base desta caracterização é o processamento de imagens. Foram aplicadas técnicas de realce (brilho, saturação, equalização do histograma e filtro de mediana) nas imagens originais gerando novas imagens e em seguida a quantificação de ambos os conjuntos, utilizando descritores de textura (probabilidade máxima, momento de diferença, momento inverso de diferença, entropia e uniformidade). Os resultados mostram que, comparadas às originais, as imagens que passaram por técnicas de realce apresentaram melhoras quando gerados seus modelos tridimensionais. / X-ray Computed Microtomography (μCT) allows a non destructive analysis of samples besides making it possible to reuse them. μCT also allows the reconstruction of tridimensional objects from its transverse sections obtained intersecting the sample through parallel planes. μCT devices offer the user several configuration options which alter the quality of the images obtained affecting, this way, the results expected. In this study, the characterization and analysis of μCT images generated by the X-ray tomograph scannerSkyScan1174 Compact Micro-CT was performed. The basis of this characterization is the processing of images. Enhancement techniques were applied (brightness, saturation, histogram equalization and median filter) in the original images creating new images. Next, the quantification of both sets was performed, using texture descriptors (maximum likelihood, moment of difference, inverse difference moment , entropy and uniformity). The results show that, compared to the originals, the images which went through enhancement techniques had improved when their three-dimensional models were generated.
162

Relação entre a elastância pleural e efetividade da pleurodese no derrame pleural maligno recidivante / Relationship between the success of bedside pleurodesis and pleural elastance in recurrent malignant pleural effusion

Pedro Henrique Xavier Nabuco de Araujo 30 April 2015 (has links)
Introdução: O tratamento para o derrame pleural maligno recidivado tem caráter paliativo, sendo a pleurodese o método mais utilizado. Contudo, nem todos os procedimentos são efetivos, em parte por um encarceramento do pulmão pela pleura visceral espessada que impede o contato entre os folhetos pleurais e subsequente pleurodese efetiva. A elastância pleural reflete o grau de encarceramento da pleura visceral, contudo sua correlação com a efetividade da pleurodese não é bem conhecido. Objetivo: Analisar a correlação entre a elastância pleural e a efetividade radiológica (quantificada por tomografia de tórax) da pleurodese realizada através de cateteres pleurais. Os objetivos secundários deste estudo são: correlacionar a elastância pleural com a qualidade de vida, graus de dispneia e dor após o procedimento, efetividade clínica, complicações e mortalidade. Correlacionar a posição da extremidade do cateter pleural com o sucesso radiológico e clínico da pleurodese. Métodos: Estudo prospectivo com 131 pacientes candidatos a pleurodese por instilação de nitrato de prata ou talco mineral por cateter pleural. As pressões pleurais foram aferidas através de manômetro hidrostático ou de transdutor eletrônico de pressão vascular durante o esvaziamento do líquido e usadas para calcular a elastância pleural, em cm H2O/L. A efetividade radiológica foi avaliada pelos volumes pleurais medidos por tomografias computadorizadas de tórax logo após a drenagem e 30 dias após a pleurodese. A efetividade clínica foi avaliada conforme a necessidade de procedimentos adicionais para controle de sintomas. A qualidade de vida foi avaliada através do questionário geral da OMS. A avaliação da dor foi feita pela quantificação na Escala Visual Analógica de Dor. A análise da dispneia foi realizada através da quantificação da funcionalidade na escala de dispneia do British Medical Research Council. Todos esses questionários foram aplicados antes da drenagem, 30 dias após pleurodese e, então, trimestralmente. Para a análise da segurança dos procedimentos foram considerados os tempos de internação e de drenagem e a ocorrência de complicações. Todos os pacientes foram seguidos até o óbito ou até o término do estudo, em novembro de 2014, registrando as complicações e as datas do óbito para a construção da curva de sobrevida. Resultados: Avaliamos 87 pacientes de um total de 131 recrutados. Não houve diferença entre os volumes pleurais nas duas tomografias realizadas. A efetividade clínica foi observada em 86,20% dos pacientes. Não houve diferença em nenhum dos domínios da qualidade de vida. Encontramos diferenças entre a dispneia e a dor aferidas 30 dias após a pleurodese e antes da drenagem. Complicações ocorreram em 14,94% dos casos. A mediana da sobrevida global foi de 16 meses. Não foram encontradas correlações entre as elastâncias pleurais em 400 ml, 800 ml e total com nenhum dos desfechos radiológicos, clínicos (efetividade clínica, qualidade de vida, dispneia, dor e complicações) ou com a sobrevida dos pacientes. A posição da ponta do cateter pleural não se correlacionou com o sucesso radiológico ou clínico da pleurodese. Conclusões: A elastância pleural não se mostrou, até o presente momento, capaz de predizer os defechos radiológicos, clínicos e a sobrevida em pacientes submetidos a pleurodese / Background: The treatment of recurrent malignant pleural effusion has a palliative purpose. Pleurodesis is the most used method. However, not all the procedures are effective, in part because of the lung entrapment by the visceral pleura, preventing the contact between the pleural surfaces and subsequente effective pleurodesis. The pleural elastance reflects the degree of entrapment of the visceral pleura, but its correlation with the effectiveness of pleurodesis is not well known. Objetive: To evaluate the correlation between pleural elastance and radiological effectiveness (measured by tomography) of bedside pleurodesis. The secondary objectives of this study are: correlating the pleural elastance with quality of life, degree of dyspnea and pain after the procedure, clinical effectiveness, complications and mortality. Evaluate the role of intrapleural position of the pleural catheter in early lung expansion and success of pleurodesis. Methods: Prospective study including 131 patients with recurrent malignant pleural effusion candidates for treatment with bedside pleurodesis with silver nitrate or mineral talc. Pleural pressures were measured through hydrostatic gauge or electronic pressure transducer during emptying of effusion and used to calculate the pleural elastance in cm H2O/L. Pleural volumes measured by CT scans of the chest after drainage and 30 days after pleurodesis were assess the radiological effectiveness. The clinical effectiveness was evaluated as the need for additional procedures to control symptoms. The quality of life was assessed using the WHO general questionnaire. Quantifying the Visual Analog Scale of Pain did pain assessment. Measuring the functionality in the British Medical Research Council dyspnea scale made the analysis of dyspnea. All these questionnaires were applied prior to drainage, 30 days after pleurodesis and then quarterly. Results: We evaluated 87 patients of a total of 131 recruited. There was no difference between the two pleural volumes CT scans performed. The clinical effectiveness was observed in 86.20% of patients. There was no difference in any of the domains of quality of life. We found differences between dyspnea and pain measured 30 days after pleurodesis and before draining. Complications occurred in 14.94% of cases. The median overall survival was 16 months. No correlations between pleural elastance in 400 ml, 800 ml and complete were found with all the imaging, clinical (clinical effectiveness, quality of life, dyspnea, pain and complications) or with patient survival outcomes. The tip of the pleural catheter was not correlated with the radiological or clinical success of pleurodesis. Conclusions: The pleural elastance was not, so far, able to predict the radiological outcomes, clinical outcomes and survival in patients undergoing bedside pleurodesis
163

Trombose venosa profunda e tromboembolismo pulmonar no pós-operatório de cirurgia de revascularização miocárdica: pesquisa diagnóstica independente de suspeita clínica / Deep vein thrombosis and pulmonary embolism in the postoperative coronary artery bypass grafting: diagnosis investigation regardless of clinical suspicion

Vitor Ramos Borges Viana 19 November 2015 (has links)
Introdução: O termo tromboembolismo venoso (TEV) engloba trombose venosa profunda (TVP) e/ou tromboembolismo pulmonar (TEP). TEV tem sido considerado incomum após cirurgia de revascularização miocárdica (CRM), e Diretrizes recomendam profilaxia mecânica para todos os pacientes e acrescentar profilaxia com heparina apenas se o tempo de internação hospitalar for prolongado por complicações não hemorrágicas (Grau 2C). Objetivo: Pesquisar o diagnóstico de TEV no pós-operatório de CRM, independente de suspeita clínica, e analisar se os resultados podem contribuir para melhor definição das características clínicas de TEV após CRM. Métodos: Em estudo observacional, prospectivo, unicêntrico, 100 pacientes com doença arterial coronariana crônica realizaram tomografia computadorizada da artéria pulmonar (multidetectores-64) e ultrassonografia compressiva dos membros inferiores após CRM eletiva. Pacientes com alto risco para TEV foram excluídos. Resultados: Por livre escolha dos cirurgiões, 83 cirurgias foram realizadas com circulação extracorpórea e 17 sem extracorpórea. Em média, tomografia e ultrassonografia foram realizadas 7 ± 3 dias após a cirurgia. TEP isolada foi observada em 13/100 (13%), TEP e TVP simultâneos em 8/100 (8%), e TVP isolada em 4/100 (4%) pacientes, totalizando 25/100 (25%) TEVs. Entre as 21 TEPs, 3/21 (14%) envolveram artérias subsegmentares, 15/21 (71%) artérias segmentares, 1/21 (5%) artéria lobar e 2/21 (10%) artérias pulmonares centrais (tronco da artéria pulmonar e/ou seus ramos principais). Das 12 TVPs, todas foram distais (abaixo da veia poplítea) e 2/12 (17%) foram também proximais; 5/12 (42%) foram unilaterais, das quais 3/5 (60%) acometeram a perna contralateral à safenectomia. Nenhum TEV causou instabilidade hemodinâmica e nenhum deles foi clinicamente suspeitado. Conclusões: TEV é frequente e subdiagnosticado após CRM, talvez porque a maioria tenha localização distal e porque os procedimentos habituais desta cirurgia dificultam a suspeita diagnóstica. Os resultados enfatizam a recomendação de recentes Diretrizes que sugerem profilaxia mecânica para todos os pacientes, e ressaltam a necessidade de estudos randomizados para avaliar a relação de benefícios e os riscos de profilaxia farmacológica / Background: Venous thromboembolism (VTE) includes deep vein thrombosis (DVT) and/or pulmonary embolism (PE). Currently, VTE has been considered uncommon after coronary artery bypass grafting (CABG) and Guidelines suggest mechanical prophylaxis and adding prophylactic heparin if hospital course is prolonged by nonhemorrhagic complications (Grade2C). Objective: To search VTE after CABG, independent of clinical suspicion, and to analyze whether the results can aid in better defining the clinical characteristics of VTE after CABG. Methods: In a prospective, observational, single-center study, 100 patients with coronary artery disease underwent computed tomographic pulmonary angiography (multidetector-64) and lower-extremity venous compressive ultrasound after elective CABG. Patients at high risk for VTE were excluded. Results: At the discretion of surgeons, 83 surgeries were on-pump and 17 off-pump. On average, tomography and ultrasound were performed 7 ± 3 days after CABG. Isolated PE was observed in 13/100 (13%) patients, simultaneous PE and DVT in 8/100 (8%), and isolated DVT in 4/100 (4%), totaling 25/100 (25%) VTEs. Of the PEs 3/21 (14%) involved subsegmental, 15/21 (71%) segmental, 1/21 (5%) lobar and 2/21 (10%) central pulmonary arteries. Of the 12 DVTs all were distal (below the popliteal vein) and 2/12 (17%) were also proximal; 5/12 (42%) were unilateral, of which 3/5 (60%) on the contralateral vein saphenous harvested leg. No VTE caused hemodynamic instability and none was clinically suspected. Conclusions: VTE is frequent and underdiagnosed perhaps because the majority is distally localized and because the ordinary procedures of GABG conceal the diagnostic suspicion. The results emphasize the current guidelines\' recommendation suggesting mechanical prophylaxis for all patients and highlight the necessity of randomized studies to assess the risk/benefit ratio of pharmacological prophylaxis
164

Análise tridimensional tomográfica das dimensões da cavidade nasal e do espaço aéreo nasal e faríngeo superior de indivíduos submetidos à expansão da maxila cirurgicamente assistida / Three-dimensional tomographic analysis of the dimensions of the nasal cavity and nasal and upper pharyngeal airway space in subjects submitted to surgically assisted rapid maxillary expansion

Eduardo Stedile Fiamoncini 09 March 2017 (has links)
A expansão da maxila cirurgicamente assistida (EMCA) tem como principal objetivo o aumento da dimensão transversal da arcada dentária superior em indivíduos com atresia maxilar. Seus efeitos não são restritos à maxila, atuando também sobre a cavidade nasal e espaço aéreo faríngeo. O presente estudo teve o objetivo de avaliar a ocorrência de alterações dimensionais da cavidade nasal e no espaço aéreo nasal e faríngeo superior em indivíduos submetidos a expansão maxilar cirurgicamente assistida, por meio de 2 osteotomias diferentes. As estruturas do espaço aéreo nasal e faríngeo foram analisadas por meio de tomografias computadorizadas de feixe cônico pré e pós-operatórias de 29 indivíduos adultos, submetidos à expansão de maxila cirurgicamente assistida. Mensuração volumétrica do espaço aéreo nasal e faríngeo superior e medidas lineares das dimensões da cavidade nasal foram realizadas por meio do uso do software Dolphin Imaging 11,7. Os dados obtidos foram tabulados e submetidos à análise estatística pelos testes de variância ANOVA e Tukey (p<0,05). Os resultados mostraram que ambas as osteotomias foram eficazes na correção da deficiência transversal da maxila e apresentaram efeitos semelhantes sobre a cavidade nasal e o espaço aéreo faríngeo. Foi verificado aumento de volume do espaço aéreo faríngeo, também na região da hipofaringe. Além disso observou-se que a EMCA promove um aumento na largura do assoalho da cavidade nasal após a expansão, e, consequentemente aumento no volume do espaço aéreo nasal. / The main objective of the surgically assisted rapid maxillary expansion (SARME) is to increase the transversal dimension of the upper dental arch in individuals with maxillary atresia. Its effects are not restricted to the maxilla, also acting on the nasal cavity and pharyngeal airway. The present study aimed to evaluate the occurrence of dimensional changes in the nasal cavity and nasal and upper pharyngeal airway space in individuals submitted to surgically assisted maxillary expansion using 2 different osteotomies. Nasal and pharyngeal airway space structures were analyzed by pre-and post-operative cone beam computed tomography scans of 29 adult subjects submitted to surgically assisted maxillary expansion. Volumetric measurement of the nasal and upper pharyngeal airway and linear measurements of the nasal cavity were performed using Dolphin Imaging 11,7 software. The data were tabulated and submitted to statistical analysis by ANOVA analysis of variance and Tukey test (p <0,05). The results showed that both osteotomies were effective in correcting the transverse maxillary deficiency and presented similar effects on the nasal cavity and pharyngeal airway space. There was an increase in the volume of pharyngeal airway, also observed in the hypopharynx region. In addition, it was observed that SARME promotes an increase in the floor width of the nasal cavity after expansion, and, consequently, an increase in nasal airway volume.
165

Necrose da gordura epipericárdica: análise clínica e radiológica de uma entidade pouco conhecida / Epipericardial fat necrosis: clinical and radiological analysis of?an unknown entity

Karina de Souza Giassi 08 November 2016 (has links)
Introdução: a necrose da gordura epipericárdica é uma entidade caracterizada por dor torácica súbita de forte intensidade e ventilatório-dependente em indivíduos previamente hígidos, com menos de 50 casos descritos na literatura. O achado característico na tomografia computadorizada de tórax é de uma lesão arredondada com atenuação de gordura e graus variáveis de densificação dos planos adiposos adjacentes localizada na gordura epipericárdica. O tratamento é sintomático com analgésicos e as alterações radiológicas tendem a regredir em poucas semanas. O aumento do número de casos, nos últimos anos, sugere que a entidade possa ser subdiagnosticada. O objetivo do estudo foi estimar a frequência da necrose numa população e comparar dados clínicos e laboratoriais com um grupo controle. Material e Métodos: 7463 tomografias computadorizadas de tórax realizadas no pronto atendimento de um hospital quaternário, de julho de 2011 a dezembro de 2014 foram avaliadas por um radiologista na busca de imagens compatíveis com necrose da gordura epipericárdica. Vinte pacientes foram selecionados e comparados com um grupo controle pareado por idade e sexo, numa proporção de 1:5 pacientes com dor torácica atípica, que também realizaram tomografia computadorizada de tórax neste período. Os dados clínicos e laboratoriais foram comparados por meio de modelos de regressão linear e os aspectos de imagem e os relatórios das tomografias dos pacientes com a necrose foram avaliados individualmente. A frequência da NGE nos pacientes que realizaram tomografia computadorizada de tórax no pronto atendimento por dor torácica foi estimada. O estudo obteve aprovação do Comitê de Ética. Resultados: a média de idade dos pacientes com a necrose foi 42 ± 13 anos e, desses, 25% mulheres (5 pacientes). A necrose esteve presente em 2.15% dos indivíduos que realizaram tomografia de tórax por dor torácica e em 0.26% de todos os pacientes que realizaram tomografia de tórax no pronto atendimento. A lesão é mais frequente do lado esquerdo (p = 0.01, IC = 0.56-0.94) e está associada à derrame pleural ipsilateral (p=0.01, IC 0.36-0.80) e atelectasia (p=0.01, IC 0.58-0.99) (p=0.01, IC 0.36-0.80). No contexto de dor torácica não coronariana, a necrose tem maior probabilidade de ocorrer na ausência de outros sintomas (p=0.005, IC -5.83, -1.27) e com o não uso de medicamentos (p= 0.01 e IC-3.33, -0.40). A análise dos relatórios das tomografias de tórax mostrou um aumento nas taxas de diagnóstico ao longo dos anos. Conclusão: pacientes com dor torácica atípica que não fazem uso de medicamentos e não possuem outros sintomas associados na ocasião do atendimento exibem maior probabilidade de apresentar necrose da gordura epipericárdica. A incidência da necrose na população estudada foi de 2.15%. O conhecimento da entidade contribui para a melhora da taxa de diagnóstico / Introduction: Epipericardial fat necrosis is characteryzed by an acute onset of pleuritic chest pain in previously healthy patients. There are less than 50 cases described in english literature. The diagnosis is made by chest tomography and the deffinitive finding is a small ovoid fat attenuation lesion with mild to moderate surrounding strandings inside the epipericardial fat. The treatment is symptomatic, by relieving the symptoms with analgesics, and the radiological findings tend to disappear in a few weeks. There is an important raise of the diagnosis in the last years, what suggests that epipericardial fat necrosis is probably underdiagnosed. The objective of the study is to estimate the frequency of the necrosis in a group of patients and to compare clinical and laboratorial data with a control group. Material and Methods: The Ethics Committee approved this study. The 7463 chest tomography were performed in the emergency department of a quaternary hospital from July 2011 to December 2014. One radiologist read the images of all chest tomography and sought for image findings compatible with epipericardial fat necrosis. Twenty patients were diagnosed with epipericardial fat necrosis and compared with a control group paired by age and sex. The control group consisted of 100 patients with non-coronary chest pain who performed a chest tomography in the same period. The clinical and laboratorial data were compared using linear regression models. The imaging findings and the radiology reports were evaluated. The frequency of epipericardial fat necrosis in this group of patients was estimated. Results: The mean age of the necrosis group was 42 ± 13 years (25% women). Epipericardial fat necrosis was present in 2.15% of the patients who performed a chest tomography because of chest pain and in 0.26% of all patients that performed a chest tomography for any reason in the emergency department in the period. Epipericardial fat necrosis is more frequent in the left side (p = 0.01, IC = 0.56-0.94). It is associated with ipsilateral pleural effusion (p=0.01, IC 0.36-0.80) and atelectasis (p=0.01, IC 0.58-0.99). Epipericardial fat necrosis is more likely to occur in the absence of other symptoms (p=0.005, IC -5.83, -1.27) and in patients who are not in use of any medication (p= 0.01 e IC-3.33, -0.40). The radiological reports demonstrated increased rates of the diagnosis of epipericardial fat necrosis over the years. Conclusion: Patients who are in the emergency department with isolated atipical acute chest pain and are not in use of medications are more likely to have epipericardial fat necrosis. The frequency of the necrosis in this population was 2.15%. The knowledge of the entity leads to an increased rate of radiological diagnosis
166

Detecção da abertura e colapso alveolar durante o ciclo ventilatório através da tomografia de impedância elétrica / Tidal recruitment detection by Electrical Impedance Tomography in an experimental model

Raquel Belmino de Souza 25 November 2011 (has links)
Introdução: A Abertura e fechamento alveolar a cada ciclo respiratório (TR) é mecanismo de lesão pulmonar associada à ventilação mecânica. É frequente, especialmente em pacientes com lesão pulmonar aguda/ sindrome do desconforto respiratório agudo, mas pode ocorrer em pulmões normais, devido à pressão expiratória final positiva (PEEP) insuficiente. A fração inspirada de oxigênio (FiO2) também pode ter um papel na modulação da lesão pulmonar: frações mais baixas, em situação de relação ventilação perfusão (V/Q) crítica, podem retardar o colapso alveolar. A Tomografia de Impedância Elétrica (TIE) é uma nova ferramenta de imagem não invasiva, à beira do leito, que reconstrói imagens transversas da resistividade dos tecidos torácicos, obtidas a partir de uma corrente elétrica injetada por eletrodos colocados circunferencialmente no tórax. Atualmente, o padrão ouro de detecção de TR é a tomografia computadorizada (TC), que utiliza radiação, transporte de pacientes para sua execução, exigindo manobras que podem ocasionar a instabilização dos pacientes. Hipótese deste estudo: é possível detectar e quantificar a ocorrência de TR com TIE. Métodos: 7 suinos traqueostomizados, sob sedação, bloqueio neuromuscular e ventilação mecânica, foram submetidos a manobra de recrutamento alveolar (MRA) em pressão controlada, com pressão platô=50 cmH2O, PEEP=35 cmH2O, aplicada por 2 minutos. Seguiu-se ventilação com volume controlado, posição supina, volume corrente (VT) = 10 ml/kg, fluxo 10l/min FR=10irpm, FiO2=100% e PEEP decremental (20-10-3cmH2O), em passos de 10 minutos. Ao final de cada passo, os animais foram submetidos a uma pressão positiva contínua sobre as vias aéreas em dois níveis, quando se procedeu à TC: pressão de platô (representando inspiração) e PEEP (expiração). Imagens de TIE foram adquiridas continuamente. Os animais foram submetidos à nova MRA, repetindo-se o protocolo em FiO2=40%. Após lesão pulmonar (lavagem pulmonar com SF 0,9% até atingir SpO2< 95%), os passos acima foram repetidos. Para detecção de TR pela TIE, dois métodos foram testados, um método original proposto por este estudo, baseado nas variações de complacência regional (pixel a pixel) ao longo do volume corrente (Método1) e um método descrito em estudo recente por Putensen et al. (Método2). Ambos foram comparados à TC. Resultados: Ocorreu colapso progressivo durante PEEP decremental, sempre maior na FiO2=100% (versus 40%) e após lesão (versus pré-lesão) para as PEEPs correspondentes. A análise de regressão linear, Métodos 1 e 2 para TR em relação à TC evidenciou; Método 1 - R²=0,578 e Método 2 - R²=0,409. As correlações foram melhores quando se considerou apenas as medidas a 100%: R²=0,756 (Método 1) e R2=0,646 (Método 2). Curva ROC; Método 1- área sob a curva: 0,86 e Método2 - 0,79. Regressão logística; Método1 superior ao Método2. Pela ANOVA avaliamos PEEP, lesão, FiO2 e P.Platô na detecção de TR pela TC e Método1..A principal difrerença foi não haver influência da FiO2 sobre TR, Método1 Conclusão: O Método 1 foi superior ao Método2 na detecção de TR, com sensibilidade e especificidade suficiente para se avaliar a utilização clínica. A detecção de TR pelo Método1, não foi influenciada pela FiO2, ao contrário da TC. Estes achados foram compatíveis com os resultados de mecânica pulmonar ( pressão de platô). Portanto, o Método1 foi mais sensível que a TC, pois foi capaz de detectar TR mesmo em situações de ventilação pouco acima do V/Q crítico nas situações de FiO2 de 40%, ao contrário da TC. A TIE não sofreu alterações como o efeito de volume parcial como a TC / Introduction: Cyclic opening and closure of alveolar units during the respiratory cycle, or tidal recruitment (TR), is a harmful mechanism of ventilation induced lung injury. It is frequent, especially in acute lung injury and acute respiratory distress syndrome patients, but can occur in normal lungs under mechanical ventilation, because of an insufficient PEEP. Oxygen concentration (FiO2) can modulate collapse and low FiO2 can delay it. Electrical Impedance tomography (EIT) is a noninvasive imaging tool that reconstructs a cross-sectional image of lungs regional resistivity using electrodes placed around the thorax. EIT is a useful imaging tool for regional ventilation monitoring, as proved by many studies. We hypothesized that is possible to detect and quantify the occurrence of TR by EIT. Seven pigs tracheostomized, sedated and using neuromuscular blockade were submitted to mechanical ventilation. A recruitment maneuver (RM) using plateau pressure = 50cmH2O and positive end expiratory pressure (PEEP) = 35cmH2O for 2 minutes was applied. After, animals were ventilated in volume controlled ventilation mode (VCV), with a tidal volume (Vt) =10ml/kg, inspiratory flow=10l/min, respiratory frequency=10irpm, FiO2=100%. Decremental PEEP (20-10-3cmH2O) steps were applied with 10 minutes intervals between them. Thoracic computed tomography (CT) images were done with a continuous positive airway pressure (CPAP) = Plateau pressure achieved in VCV and PEEP applied, simulating an inspiration and expiration respectively. EIT was acquired continuously during the protocol. RM was repeated and then protocol was repeated, using FiO2=40%. Lung injury was induced (with lung lavage - SF 0.9% until SpO2< 95%). After protocol was repeated including both FiO2. Two TR detectors were tested; an original imaging tool created by our group (Method 1) and a second imaging tool created in a recent study by Putensen. (Method 2). Both methods were compared to CT. Results: A progressive alveolar collapse during decremental PEEP was observed, always greater with FiO2=100% (versus FiO2=40%) and after lung injury (versus before lung injury). Linear regression analysis for Methods 1 and 2 showed for Method1 R2=0.578 and Method 2 R2=0,409. Correlations were better when FiO2=100% was considered individually; Method1 - R²=0,756 and Method2 - R²=0,646. ROC curve presented an area under the curve better for Method1 (0,86) related to Method2 (0,79). Logistic regression also showed better result for Method1. ANOVA was used to test influence of variables as PEEP, lung lesion, FiO2 and Plateau pressure on tidal recruitment. Method1 and CT were tested. The main difference between them was that Method 1 was not influenced by FiO2. Conclusion: Method 1 was superior than 2 for TR detection with sufficient specificity and sensibility for a trial on clinical application. Tidal recruitment detection by Method1 was not influenced by FiO2, but it was for CT, what was supported by results of lung mechanic (plateau pressure). Under lower FiO2 (40%) occurred an underestimation of TR by CT, once the change in ventilation occurs even in lower FiO2 which is not detected by CT. CT is also influenced by partial volume effect, what didn´t occurred with EIT
167

Papel da angiotomografia no diagnóstico de morte encefálica: revisão sistemática / Role of computed tomography angiography in diagnosing brain death: a systematic review

Sergio Paulo Brasil Lima 09 May 2016 (has links)
Introdução: Transplantes de órgãos ocorrem principalmente devido a doações provenientes de pacientes que apresentam morte encefálica (ME). Algumas situações limitam o diagnóstico de ME baseado apenas no exame neurológico, sendo necessário utilizar um exame de imagem ou gráfico para esta confirmação. No Brasil, o exame complementar é obrigatório por lei para todos os casos suspeitos. A maioria dos métodos complementares utilizados para confirmação de ME não está disponível em muitos locais do Brasil. Neste contexto, a angiografia por tomografia computadorizada (ATC) representaria uma alternativa, devido à presença de equipamentos de tomografia em diversos hospitais brasileiros. Porém, a capacidade de este exame reconhecer a interrupção da circulação intracraniana é desconhecida. Métodos: Realizou-se revisão sistemática para verificar evidência na literatura sobre o uso de ATC como teste avaliador de ME. Foram seguidas diretrizes de busca e extração de dados, sendo o QUADAS 2 utilizado para verificar risco de vieses e qualidade dos estudos. Os dados foram sumarizados para produzir metanálise. Resultados: Dez estudos com alto risco de vieses foram encontrados. Devido à falta de estudos controlados, não se obteve dados de especificidade. Trezentos e vinte e dois pacientes foram elegíveis para metanálise, a qual revelou 84,7% de sensibilidade. Houve variação de protocolos de avaliação das imagens de ATC entre os estudos, sobre a definição de resultados positivos ou negativos. Conclusão: ATC apresenta alta sensibilidade para detectar interrupção de circulação intracraniana entre pacientes com avaliação clínica compatível com ME. Este nível de evidência é similar ao de outros métodos utilizados no mundo. Há falta de estudos bem desenhados neste tema / Background: Organ transplantation depends more often of donation from brain dead (BD) individuals. Several complications make the diagnosis of BD medically challenging and a complimentary method is needed for confirmation. Additionally, in Brazil, the complimentary diagnosis is mandatory by law, despite there are still many areas where these methods are not available. In this context, computed tomography angiography (CTA) could represent a valuable alternative, because of its widespread presence. However, the reliability of CTA for confirming brain circulatory arrest remains unclear. Methods: A systematic review was performed to identify relevant studies regarding the use of CTA as ancillary test for BD confirmation. Guidelines for online search were followed, and the QUADAS 2 tool was used to verify study quality. Data from the studies retrieved were extracted aiming to perform the meta-analysis. Results: Ten low quality studies were found. Due to the absence of controls in all studies, specificity could not be calculated. Three hundred twenty-two patients were eligible for the meta-analysis, which exhibited 84,7% sensitivity. CTA image evaluation protocol exhibited variations between medical institutions regarding which intracranial vessels should be considered to determine positive or negative test results. Conclusions: For patients who were previously diagnosed with BD according to clinical criteria, CTA demonstrated high sensitivity to verify intracranial circulatory arrest. The current evidence that supports the use of CTA in BD diagnosis is comparable to other methods applied worldwide. Considering the importance of this subject, high quality studies are currently missing and needed
168

Influence of anatomical location and FOV size on cone-beam computed tomography gray values = Análise da influência da localização anatômica e tamanho do FOV nos valores de cinza em imagens de tomografia computadorizada de feixe cônico / Análise da influência da localização anatômica e tamanho do FOV nos valores de cinza em imagens de tomografia computadorizada de feixe cônico

Oliveira, Matheus Lima de, 1984- 02 May 2013 (has links)
Orientador: Guilherme Monteiro Tosoni / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T22:12:50Z (GMT). No. of bitstreams: 1 Oliveira_MatheusLimade_D.pdf: 24389100 bytes, checksum: b2e18d1167061c00f8285f26e1f8d746 (MD5) Previous issue date: 2013 / Resumo: O objetivo deste estudo foi avaliar a influência da região anatômica e do tamanho do FOV (field of view) nos valores de cinza em imagens de tomografia computadorizada de feixe cônico (TCFC). Soluções homogêneas de fosfato de potássio dibásico (K2HPO4) foram preparadas em sete diferentes concentrações e armazenadas separadamente em tubos de polipropileno. Um phantom de uma cabeça humana teve seis dentes extraídos - um incisivo central um primeiro prémolar e um primeiro molar da maxila e da mandíbula - e substituídos por esses tubos, que foram escaneados separadamente pelos aparelhos NewTom 3G, NewTom 5G e 3D Accuitomo 170, sob diferentes tamanhos de FOV. Em cortes axiais, valores médios de cinza foram obtidos em cinco níveis diferentes dentro de cada tubo de polipropileno e a média foi calculada. Para cada aparelho, análise de regressão linear avaliou a relação entre os valores médios de cinza e a concentração de K2HPO4 em seis regiões anatômicas, sob os diferentes FOVs. Coeficiente de determinação (R2) foi calculado. Nos três aparelhos, a correlação linear entre os valores de cinza e as concentrações de K2HPO4 variou entre as regiões anatômicas e os tamanhos de FOV (0,93 < R2 < 0,99). Desse modo, pode se concluir que a relação entre os valores de cinza em imagens de TCFC e a densidade do objeto não é uniforme por todo o arco dentário e é influenciada pelo tamanho do FOV nos três aparelhos de TCFC testados. A comparação desses valores obtidos em diferentes regiões anatômicas e com diferentes tamanhos de FOV não é confiável / Abstract: The aim of this study was to evaluate the influence of anatomical location and FOV (field of view) size in CBCT numbers. Homogeneous solutions of dipotassium phosphate (K2HPO4) were prepared at seven different concentrations and stored separately in polypropylene tubes. Six teeth were extracted from a human head phantom - the upper and lower central incisors, first premolars and first molars - and replaced by the tubes, which were scanned separately by NewTom 3G, NewTom 5G and 3D Accuitomo 170 under different FOV sizes. In axial sections, CBCT numbers were obtained at five levels within each polypropylene tube, and the average was calculated. For each CBCT unit, linear regression analysis evaluated the relationship between CBCT numbers and the concentration of K2HPO4 in six anatomical regions, under different FOVs. Coefficient of determination (R2) was calculated. Linear correlation between CBCT numbers and concentrations of K2HPO4 ranged between anatomical regions and FOV sizes (0.93 < R2 <0.99). Thus, it can be concluded that the relationship between CBCT numbers and object density is not uniform throughout the dental arch, and is influenced by the FOV size on the three CBCT units tested in this study. The comparison of CBCT numbers from different anatomical regions and with different FOV sizes is unreliable / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
169

Etude du comportement mécanique et des mécanismes d'endommagement de pièces métalliques réalisées par fabrication additive / Studying the mechanical behaviour and the damaging mechanisms of metallic parts produced by additive manufacturing

Chastand, Victor 10 November 2016 (has links)
La fabrication additive est un procédé offrant de nouvelles opportunités aux industriels pour fabriquer des pièces complexes, sans outillage spécifique et en optimisant la matière utilisée.Cette thèse présente les propriétés mécaniques de pièces réalisées par fabrication additive et l’analyse des mécanismes d’endommagement associés, en ayant comme référence les propriétés mécaniques des procédés de fonderie et de corroyage. Ce type d’analyse est indispensable pour l’industrialisation du procédé.Les propriétés en traction et en fatigue, sur des éprouvettes en titane Ti-6Al-4V et en aluminium AlSi7Mg0,6, ont été mesurées. Les effets du procédé de fabrication, de la direction de fabrication, du post-usinage et des post-traitements thermiques ont été comparés. Les propriétés sont au moins au niveau de la fonderie.Ces résultats ont été analysés en corrélation avec les microstructures et les faciès de rupture, afin de dégager des mécanismes d’endommagement. Les critères permettant de mesurer la criticité des défauts ont été définis.Certaines de ces hypothèses ont pu être vérifiées grâce à des essais de traction in situ au micro tomographe. / Additive manufacturing offers new opportunities for industries to manufacture complex parts with no additional tooling and better optimization of the material used.This thesis is about the analysis of the mechanical properties and the damaging mechanisms of parts produced by additive manufacturing, using mechanical properties of casted and wrought parts as reference. This type of analysis is necessary in order to industrialize the process.The tensile and fatigue properties on Titanium Ti-6Al-4V and Aluminium AlSi7Mg0,6 were measured. The effects of the process, the manufacturing direction, the post-machining and the post-heat treatments were compared. Properties are at least at the level of casting.A correlation of these results with microstructures and fracture surfaces was made in order to extract the damaging mechanisms. A method to measure the criticity of the defects in a part was defined. Some of these hypotheses were verified using microtomographic in situ tensile tests.
170

Analyse par microtomographie aux rayons X de l'effondrement capillaire dans les matériaux granulaires / Investigation by means of X-ray computed tomography of capillary collapse in granular materials

Bruchon, Jean-François 04 April 2014 (has links)
Le travail présenté dans cette thèse vise à apporter une compréhension fine des couplages hydromécaniques et plus particulièrement du phénomène d'effondrement capillaire. L'utilisation de matériaux granulaires modèles observés à petites échelles grâce au microtomographe à rayons X constitue le point de départ de cette étude. Les résultats portent dans un premier temps sur la capacité à reproduire et observer le phénomène d'effondrement capillaire à l'échelle de l'éprouvette, appelée aussi échelle macroscopique. Une des premières problématiques importantes de ce projet a donc porté sur la reconstitution d'éprouvettes suffisamment lâches permettant d'observer le phénomène effondrement. Le potentiel d'effondrement, alors mesuré au simple œdomètre sur ces éprouvettes reconstituées, décroit avec la charge mécanique appliquée. En contrôlant le volume d'eau au cours de l'imbibition, les éprouvettes sont sujettes à une succession d'incréments de déformation rapides et ceci quelle que soit la dynamique de mouillage. En parallèle, l'utilisation de la technique d'analyse non destructive par microtomographie aux rayons X nous a permis de quantifier à une échelle mésoscopique (échelle de quelques grains), l'évolution de matériaux granulaires sous chargement hydrique et mécanique. Cela a été possible par l'utilisation de la technique de corrélation d'images numériques (DIC) associée à des outils d'analyse adaptés aux matériaux non saturés. Ces outils révèlent que l'hétérogénéité locale des déformations et des teneurs en eau augmente au cours de l'imbibition principalement à cause de l'effet de la gravité sur la répartition de l'eau dans l'éprouvette. L'hétérogénéité initiale des éprouvettes induite par la méthode de préparation est aussi identifiée. Cependant, malgré la présence de ces hétérogénéités, nous montrons que les mesures réalisées à l'échelle de l'éprouvette restent représentatives du comportement mésoscopique du matériau au cours de l'effondrement / This thesis deals with hydromechanical couplings in soils and more particularly focusing on the capillary collapse phenomenon. Although thoroughly studied at macroscopic scale in fine soils, the mechanisms governing capillary collapse in granular soils have been less observed.At first, the results concern the capacity to reproduce and to observe the phenomenon of capillary collapse at the scale of the specimen, called also the macroscopic scale.Thus, one of the first important objectives of this project concerned the preparation method of the specimens, which have to be loose enough to observe this phenomenon. The collapse potential, determined here by the one-dimensional collapse test, decreases with the mechanical stress. Moreover, when the quantity of water is controlled, incremental strains of specimens arise whatever the imbibition dynamic.To complement existing data, an experimental program was carried out using X-ray computed tomography (X-ray CT), a relevant tool to obtain 3D informations at grain scale. In combination with Volumetric Digital Image Correlation (V-DIC), X-ray CT also makes it possible to get information at a mesoscopic scale, at which the use of continuum mechanics still remains relevant. In this work, both microscopic and mesoscopic analyses have been carried out on a partially saturated sand subjected to gradual controlled imbibition in an oedometric cell.Local heterogeneities of strains and water contents appear during the imbibition, which are principally explained by the effect of gravity and by an inhomogeneity of the initial density.However, in spite of the existence of those localisations, by comparing the analyses at the mesoscopic and at the macroscopic scale, we show that measurements performed at the scale of the specimen are representative of the local behaviour of the material

Page generated in 0.0899 seconds