Spelling suggestions: "subject:"acrílica"" "subject:"acrílico""
181 |
Influencia dos ciclos de polimerização sobre a adaptação das bases de protese total confeccionadas com resina acrilica QC-20Padovan, Silvia Helena Marques 26 February 1999 (has links)
Orientadores: Saide Sarckis Domitti, Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T16:08:45Z (GMT). No. of bitstreams: 1
Padovan_SilviaHelenaMarques_M.pdf: 4194064 bytes, checksum: 105fde7936dddc9bb8c66110ab9ade0a (MD5)
Previous issue date: 1999 / Resumo: O objetivo deste estudo foi avaliar as alterações de adaptação em bases de prótese total, confeccionadas com resina acrílica de rápida polimerização (QC-20) em função das técnicas de polimerização. Foram confeccionados 15 modelos em gesso pedra a partir da moldagem de um modelo mestre metálico. Sobre estes modelos foram confeccionadas bases de prótese com espessura uniforme de 1,5 mm, divididas aleatoriamente em 3 grupos de 5 amostras e incluídos em muflas específicas, segundo os Grupos: 1- ciclo convencional (polimerização em banho de água aquecida a 74°C por 9 horas); 2- ciclo rápido (polimerização em água fervente em 20 minutos); e, 3- por energia de microondas (polimerização em forno de microondas a 500W por 3 minutos). Após o resfriamento das muflas em temperatura ambiente, as bases-de-prótese foram removidas, limpas, acabadas e fixadas em seus respectivos modelos com adesivo instantâneo Super Bonder (Loctite). O conjunto, base de prótese-modelo foi seccionado em três secções láterolaterais e as superfícies seccionadas lixadas numa politriz. Em cada secção foram demarcados 7 pontos referenciais para a leitura da desadaptação, verificada num microscópio comparador e os resultados obtidos foram submetidos à análise estatística e ao teste de Tukey em nível de significância de 5%. A resina acrílica QC-20 quando polimerizada pelos ciclos de 9 horas e de 20 minutos apresentou estatisticamente melhor adaptação quando comparadas ao ciclo por microondas. A maior média de desadaptação ocorreu na linha média da região posterior, quando a base foi polimerizada pelo ciclo de microondas / Abstract: The aim of this work was to evaluate changes in adaptation of denture bases made with rapid curing acrylic resin (QC-20) considering the polymerization techniques. Fifteen plaster of Paris models were made from the modeling of a metalic master mode!. Sample bases, with regular width of 1.5 mm, were made over these models, ramdomly divided ln three groups containing five replicas and incIude in specific flasks, according to the Groups: 1- convencional cycle (polymerization in water at 74°C for 9 hours); 2- rapid cycle (polymerization in boiling water for 20 minutes); and, 3-through microwave energy (polymerization in microwave oven at 500W for 3 minutes). After the flasks have been cooled at room temperature, the resin bases were removed, trimmed, and fixed on their models with instant bonder Super Bonder (Loctite). The denture base and the model set was sectioned in three latero-lateral sections and the cut surfaces polished in a politriz. ln each section, seven mark points were made to make possible the analysis of the non-adaptation. The adaptation was verified in a comparing microscope and the results were submitted to a statistical analysis and to the Tukey' s test, with a significance leveI of 5%. The acrylic resin QC-20, when polymerized through the cicles of 9 hours and 20 minutes, showed statistically better adaptation when compared to the microwave cycle. The greatest average oí non-adaptation occured in the midline oí the posterior area, when the base was polimerized through the microwave cycle / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
182 |
Comparación de la densidad de energía y grado de conversión en resinas compuestas microhíbridasCuevas Moreno, Rodolfo Carlos January 2017 (has links)
Publicación a texto completo no autorizada por el autor / Compara la densidad de energía y el grado de conversión de tres resinas compuestas fotocuradas, las cuales son denominadas como R1, R2 y R3, para el desarrollo de la investigación, así mismo se utilizan lámparas nuevas denominadas L1 y L2. En ese sentido estas muestras son sometidas a potencias de 400,500 y 1032 mw/cm2 por periodos de tiempo de 40,40 y 20s respectivamente, posteriormente son expuestas a los rayos infrarrojos del espectroscopio, el cual da una lectura de la absorbancia y transmitancia graficando picos de la cadena aromática y de la cadena alifática. Por otra parte para medir el grado de conversión se observa el porcentaje de dobles enlaces carbono-carbono sin reaccionar (% C = C), se puede determinar a partir de la relación de las intensidades de absorbancia de C = C alifático (pico a 1637 cm -1) contra un patrón interno antes y después del curado de la muestra, los datos obtenidos son tabulados, analizados y sometidos a los test de análisis de varianza y tukey, los resultados obtenidos permiten concluir que no existe diferencias significativas en los grados de conversión al aplicar los tres tipos de materiales, sin embargo si existe diferencias significativas sobre los grados de conversión al aplicar distintos niveles de densidad de energía, por lo cual permite indicar que la lámpara L1 emite insuficiente densidad de energía para lograr un adecuado grado de conversión. / Tesis
|
183 |
Propriedades mecanicas de resinas acrilicas para base de protese antes e apos metodos de reparos / Mechanical properties of denture base acrylic resins before and after repair methodsFaot, Fernanda 11 October 2006 (has links)
Orientadores: Renata Cunha Matheus Rodrigues Garcia, Altair Antoninha Del Bel Cury / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-07T23:27:29Z (GMT). No. of bitstreams: 1
Faot_Fernanda_D.pdf: 1972781 bytes, checksum: b3ce58297c07d4abe90d5b2bf79729e7 (MD5)
Previous issue date: 2006 / Resumo: Fraturas por impacto e flexão ainda são os principais problemas relatados tanto pelos portadores de próteses removíveis como pelos cirurgiões dentistas. Na tentativa de solucionar esse problema, alterações na composição química das resinas acrílicas como a inclusão de co-polímeros, adição de agente de ligação cruzada e a incorporação de partículas de borracha na forma de butadieno estireno têm sido propostas. Entretanto, poucos estudos avaliaram a incorporação destes aditivos modificadores de impacto no processo de fratura, deformação e microestrutura de resinas acrílicas. Além disso, devido à fragilidade dos materiais poliméricos a presença de trincas e fraturas em base de
próteses removíveis ainda é alta e reparos são procedimentos comuns tanto por métodos diretos ou indiretos. Entretanto, as propriedades mecânicas de resinas acrílicas reparadas ainda não estão claramente descritas. Assim, os objetivos do presente trabalho foram: I) avaliar a resistência ao impacto e a flexão, bem como tensão de ruptura, módulo Young e deslocamento de escoamento de resinas acrílicas contendo modificadores de impacto e analisar sua microestrutura; II) determinar a resistência ao impacto e flexão de resinas acrílicas para base de prótese previamente fraturadas e reparadas com resinas fotopolimerizável, autopolimerizável e termopolimerizável. Como resultado, observou-se que a resina contendo borracha considerada de alto impacto, demonstrou alta capacidade de dissipação de energia, absorção de tensão e baixo percentual de deformação; entretanto exibiu processo de fratura frágil. Com relação às resinas utilizadas para reparo, concluiu-se que reparos realizados com a mesma resina usada para confecção dos corpos-de-prova, apresentaram melhores resultados quanto à resistência mecânica / Abstract: Fractures by impact and flexural action are the main problems described by denture users and dentists. Attempting to solve this problem, modifications on the chemical composition of the acrylic resins as co-polymer inclusion, cross linking agents addition and rubber particles incorporation in the form of butadiene styrene have been described as effective and worthwhile means to improve the impact strength and fracture propagation. However, literature lacks information regarding the incorporation of these modifying impact additives in the fracture process, plastic deformation and microstructure of acrylic resins. Furthermore, due to the brittleness of the polymeric materials, the presence of cracks and fractures in the removable prosthesis denture bases still remains high. Thus, frequent repairs are somewhat common procedures in the clinical practice, being by direct or indirect methods. Therefore, the effect of the repairs materials on the mechanical properties of acrylic resins is not clearly described yet. Front of these considerations, the purposes of the present study were: I) evaluate the impact and flexural strength, as well as, stress at yield, Young modulus and displacement at yield of acrylic resins containing impact modifiers and analyze their microstructure; II) determine the impact and flexural strength of denture base acrylic resins previously fractured and repaired with visible-light, auto and heat-polymerized acrylic resins. As results, it could be observed that the acrylic resin containing rubber particles, considered as the high impact, showed high capacity of energy dissipation and stress absorption before the fracture, lower percentage of deformation, however it exhibited brittle fracture process. Regarding to acrylic resins used as repair materials, it was concluded that repairs performed with the same resin used to fabricate the specimens showed the best results for mechanical resistance / Doutorado / Protese Dental / Doutor em Clínica Odontológica
|
184 |
Desenvolvimento e caracterização de espumas rigidas com poros intercomunicantes de polimetacrilato de metila, e sua aplicação na industria ceramicaGalhardi, Antonio Cesar 21 December 1998 (has links)
Orientador: Antonio Celso Fonseca de Arruda / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-04T01:49:56Z (GMT). No. of bitstreams: 1
Galhardi_AntonioCesar_D.pdf: 10199145 bytes, checksum: 2012dd27793df7bcbe5e5b7e850aef0d (MD5)
Previous issue date: 1998 / Resumo: Este estudo descreve um método inédito para a obtenção, a partir da polimerização do Metilmetacrilato, de espumas rígidas com poros intercomunicantes . Descreve, também, a sua viabilidade tecnológica na fabricação de moldes porosos para o processo de Colagem de Barbotina sob Pressão. A caracterização das espumas, quanto às propriedades dos meios porosos, foi realizada, com sucesso, definindo-se os parâmetros fundamentais para o controle da : permeabilidade , porosidade e tamanho de poros. As propriedades mecânicas das espumas foram investigadas em formulações contendo duas resinas existentes no mercado e uma obtida experimentalmente. A sensível superioridade do Móludo de Elasticidade das formulações, contendo a resina experimental, comprovou a eficiência da metodologia empregada, principalmente no que se refere à obtenção de altos pesos moleculares e sua influência nas propriedades mecânicas das espumas. A Tomografia Computadorizada foi aplicada, como metodologia de ensaio não destrutivo , na detecção de bolhas internas. A facilidade de interpretação dos resultados permitiu a imediata adequação do processo de obtenção de espumas. Para algumas espumas selecionadas , simulou-se o processo de Colagem de Barbotina sob Pressão, investigando-se a influência da temperatura da barbotina; da pressão de trabalho e da permeabilidade das espumas. Os resultados foram suficientes para validar o processo de Colagem de Barbotina sob Pressão, que apresenta maior rapidez se comparado ao processo convencional / Abstract: This study describes an unpublished method to produce rigid foams with connected pores by the emulsion polymerization of the Methylmetacrylate monomer; and its technological feasibility in the manufature of moulds by the Slip Casting under Pressure. The main properties ofthe foams were successfully evaluated for the control of the permeability , the porosity and the pore size. The mechanical properties were evaluated for the compositions of two resins available on market and an experimental resin. The superior values of the Elastic Modulus of the foam made with the experimental resin show the efficiency of the methodology applied, specially for the production ofhigh molecular weight resins, and its influence on the foam's mechanical properties. Computerised Tomography was applied as a nondestructive test to identify internal bubbles; easy and prompt interpretation of the results made it possible to change accordingly. For several selected foams a simulation ofthe process of Slip Casting under Pressure was run; and the influence ofthe slip temperature, pressure and the foam permeability were analysed. The results, alone were sufficient to validate the process of Slip Casting under Pressure, characterised by a higher velocity than that of the traditional process / Doutorado / Materiais e Processos / Doutor em Engenharia Mecânica
|
185 |
Avaliação da desadaptação e da inclinação dental de proteses totais superiores submetidas a diferentes metodos de processamento em função da sorção de agua com alteração na temperatura e pressãoNadin, Paulo Sergio 12 December 2001 (has links)
Orientador: Celia Marisa Rizzatti Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-31T18:51:13Z (GMT). No. of bitstreams: 1
Nadin_PauloSergio_D.pdf: 3982871 bytes, checksum: 60b40819eee30b6dd20d8ff8604c5f8a (MD5)
Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi avaliar a adaptação e a alteração na inclinação dental dos primeiros molares de próteses totais superiores em função do método de polimerização, e da sorção de água apresentada pela resina, frente a alterações de pressão e temperatura de armazenagem das amostras. Foram confeccionadas 60 próteses divididas em 4 grupos: (G I) polimerizadas em água 73 :I: 2 °C / 9 horas e armazenadas em água à 37 :I: 2 °C por 30 dias; (G 11) polimerizadas em água 73 :I: 2 °C / 9 horas e armazenadas em água sob temperatura de 60 :I: 2°C, pressão de 40 Lib/PoF por 1 hora; (G lU) polimerizadas por energia de microondas 500W / 3 minutos e armazenadas em água de 37 :I: 2 °C por 30 dias; (G IV) polimerizadas por energia de microondas 500 W / 3 minutos e armazenadas em água sob temperatura de 60 :I: 2°C, pressão de 40 Lib/PoF por 1 hora. Foi feita a análise da inclinação dental nos períodos de enceramento (TO), de polimerização (TI), polimento (T2) e sorção de água (T3). Para o teste de adaptação, a base foi analisada na região de primeiros molares, em sete pontos pré-estabelecidos. Estes foram feitos nos períodos de polimento (TO) e após a de sorção de água (TI). Os dados obtidos foram submetidos à análise de variância e teste de Tukey ao nível de 5 % de significância. Estes demonstraram que as alterações mais significativas da inclinação dental ocorreram em todos os grupos após o processamento das amostras (TI), sendo de 2,3 °, 0,85 °, 2,54 °, e 3,47° para os grupos I, 11, 111 e IV respectivamente (p<0.05). Conclui-se que: 1) As maiores alterações na inclinação dos dentes ocorreram entre os períodos de enceramento e polimerização, em média 2,29 graus. 2) As alterações na inclinação dental durante o polimento e após o fenômeno de sorção de água não foram estatisticamente significantes. 3) Não houve diferença significativa na inclinação dos dentes entre os métodos de polimerização por energia de microondas e por banho de água convencional. 4) Os métodos de tratamento utilizados para sorção de água influenciaram igualmente as alterações ocorridas. 5) A melhor adaptação ocorreu na região palatina para o grupo 111 sendo em (TO) 0,142 mm e (TI) 0,134 mm. 6) Na região de tlanco observou-se a menor variação na adaptação entre TI e T2 (0,005 mm). 7) De modo geral após a sorção de água houve melhora na adaptação / Abstract: The aim of this work was to evaluate the adaptation and change in dental inclination of the first molars in upper complete dentures in function of the curing method and water sorption shown by the resin, before changes in pressure and temperature of storage of the samples. Sbcty dentures were constructed and divided into 4 groups: (G I) cured in 73° C water/ 9 hours and water sorption of37° C for 30 days; (G 11) cured in 73° C water/ 9 hours and water sorption under a temperature of 60° C, pressure of 40 Libs/inch2 per hour; (G 111) curing by microwave energy 500W/3 minutes and water sorption of 37° C for 30 days; (G IV) cured by microwave energy 500W/ 3 minutes and water sorption under a temperature of 60° C, pressure of 40Libs/inch2 per hour. An analysis was made on the dental inclination in waxing (TO), curing (TI); polishing (T2) and water sorption (T3) periods. For the adaptation test, the base was analyzed in the first molar region, in seven pre-established points. These were made in the polishing period (TO) and after water sorption (TI). The obtained data were submitted to variance analysis and Tukey's test at a 5% significance level. These demonstrated that the most significant changes of dental inclination had occurred in ali groups after the processing of the samples (TI), being of 2,3°, 0,85°, 2,54° and 3,47° for groups I, 11, 111 and IV, respectively (p<0.05). It is concluded that: 1) The biggest changes in dental inclination occurred between the waxing and curing periods, an average of 2,29 degrees. 2) The changes in dental inclination during the polishing and after the phenomenon of water sorption were statistically insignificant. 3) There was no significant difference in tooth inclination between the curing methods by microwave energy and conventional water bath. 4) The methods of treatment used for water sorption influenced equally the occurred changes. 5) The best adaptation occurred in the palatine region for group IH, being in (TO) 0,142 mm and (TI) 0,134 mm. 6) In the flange region, it was observed the least variation in adaptation between TI and T2 (0,005 mm). In a general sense, there was an improvement in adaptation after water sorption / Doutorado / Protese Dental / Doutor em Clínica Odontológica
|
186 |
Efeito do polimento quimico sobre a dureza, rugosidade superficial e resistencia ao impacto de resinas acrilicas ativadas quimica e termicamente, em varios periodos de armazenagemMesquita, Marcelo Ferraz, 1967- 29 November 1995 (has links)
Orientador: Saide Sarckis Domitti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T19:29:42Z (GMT). No. of bitstreams: 1
Mesquita_MarceloFerraz_D.pdf: 3860819 bytes, checksum: 914a84ad9f72f99136cdc17f8003ac7d (MD5)
Previous issue date: 1995 / Resumo: Este trabalho teve como objetivo avaliar o efeito do polimento químico sobre a Dureza, Rugosidade Superficial e Resistência ao Impacto de Resinas Acrílicas Ativadas Química e Termicamente, em diferentes períodos de armazenagem. Foram utilizadas 80 amostras divididas em 4 grupos de variáveis, com 5 repetições cada variável, nos períodos de tempo de 1 hora, 1 dia, 1 semana e 1 mês. Para a confecção das amostras foi utilizada uma matriz retangular de alumínio incluída em mufla, cujo molde impresso no gesso foi preenchido com resina acrílica. Após polimerizadas, as amostras divididas em dois grupos foram polidas pelos processos de polimento químico e convencional. Em seguida, foram armazenadas em água destilada a 37°C durante os períodos de tempo propostos. Decorrido o período de armazenagem, as amostras foram submetidas aos testes de Rugosidade Superficial, num rugosímetro Praxis (Rug-3); Resistência ao Impacto, numa máquina OTTO Wolpert Werke (Sistema Charpy); e Dureza, com penetrômetro Durimet. A análise estatística dos dados de rugosidade superficial revelou diferença entre as resinas quando polidas de modo convencional apenas no período de armazenagem de 1 mês. No polimento químico, em todos os períodos de armazenagem, com superioridade estatística para os valores apresentados pela resina acrílica ativada quimicamente com polimento químico em todos os períodos de armazenagem e com polimento convencional no período de armazenagem de 1 mês. Para ambas resinas, os melhores valores foram obtidos com o polimento convencional em todos os períodos de armazenagem. Com relação à resistência ao impacto, a análise estatística revelou semelhança entre as resinas quando polidas de maneira convencional, apenas no período de armazenagem de 1 mês, e no polimento químico, em todos os períodos de armazenagem, com superioridade estatística para os valores apresentados pela resina acrílica ativada quimicamente, com polimento convencional nos períodos de 1 hora, 1 dia e 1 semana de armazenagem. Para a resina acrílica ativada termicamente, o polimento químico apresentou valores superiores estatisticamente nos períodos de 1 hora, 1 dia e 1 mês de armazenagem, e para a resina acrílica ativada quimicamente, nos períodos de 1 hora e 1 mês de armazenagem. A análise estatística dos dados de Dureza revelou diferença entre as resinas quando polidas de maneira convencional, com superioridade para a resina acrílica ativada termicamente com 1 dia de armazenagem, e para a resina acrílica ativada quimicamente com 1 mês de armazenagem. Com polimento químico, a resina acrílica ativada termicamente apresentou superioridade estatística apenas nos períodos de 1 dia e 1 semana de armazenagem. Para a resina acrílica ativada termicamente, foi apresentada diferença estatística entre os polimentos apenas no período de armazenagem de 1 dia, com superioridade para o polimento convencional. Para a resina acrílica ativada quimicamente, o polimento convencional apresentou valores superiores estatisticamente em todos os períodos de armazenagem / Abstract: The purpose of this study was to evaluate the effect of chemical polishing on the hardness, surface roughness and impact resistance of the self-cured acrylic resin and conventional heat-cured acrylic resins, in various storage times. Eight specimens were used divided into four variable groups with tive repetitions each one, in the following periods of time: 1 hour, 1 day, 1 week and 1 month. To make specimens, a rectangular matrix of aluminium included into flask was used, whose mold printed on the gypsum was fulfilled with acrylic resin. After curing, the specimens divided into two groups were polished with chemical and conventional polishing. Thereafter, they were stored in distilled water at 37°C during the periods proposed. Elapsed the period of storage, the specimens were submitted to the tests of surface roughness in the Praxis (Rug-3) roughness gauge; impact resistance in the testing machine OTTO Wolpert Werke (Charpy System); and hardness with Durimet hardness gauge. The statistical analysis of the surface roughness data revealed difference between the resins when polished in the conventional manner only in a storage period of 1 month. On the chemical polishing, this difference was obselVed in all the periods of the storage, with statistical superiority for the values obtained with chemical polishing in all the periods of the storage and with conventional polishing in a storage period of 1 month. For both the self-cured and heat-cured acrylic resins, the best values were obtained with the conventional polishing in all the periods of the storage. Regarding the impact resistance, the statistical analysis revealed similarity between the resins when poIished in the conventional manner, only in a storage period of 1 month, and in the chemical polishing, in all the periods of the storage, with statistical superiority for the values obtained for the self-cured acrylic resin, with conventional polishing in a storage period of 1 hour, 1 day and 1 week. For the heat-cured acrylic resin, the chemical poIi.shing showed values with statistical superiority in a storage period of 1 hour, 1 day and 1 month, and for the self-cured acrylic resin, in a storage period of I hour and 1 month. The data statistical analysis of the hardness revealed difference between the resins when polished in the conventional manner, with superiority for the heat-cured acrylic resin with a storage period of 1 day, and for the self-cured acrylic resin, with a storage period of 1 month. With the chemical polishing, the heat-cured acrylic resin showed statistical superiority only in a storage period of 1 day and 1 week. For the heat-cured acrylic resin, a difference between the polishings was showed only in a storage period of 1 day, with superiority for the conventional polishing. For the self-cured acrylic resin, the conventional polishing showed values with statistical superiority in alI the periods of the storage / Doutorado / Protese Dental / Doutor em Clínica Odontológica
|
187 |
Avaliação da alteração de cor e rugosidade média superficial de resinas acrílicas usadas em base de próteses após imersão em desinfetantes químicos e bebidas / Evaluation of the color alteration and superficial roughness of the denture base acrylic resins after immersion in chemical didinfectants and beveragesFernandes, Flávio Henrique Carriço Nogueira 24 September 2009 (has links)
Pacientes submetidos a procedimento protéticos estão expostos a microorganismos patogênicos podendo ocorrer desenvolvimento de doenças e infecção cruzada entre pacientes e equipe odontológica.As próteses devem ser desinfetadas com substâncias que não provoquem alterações nas propriedades mecânicas e físicas principalmente em associação com a ingestão de bebidas com teor alcoólico ou baixo pH. O objetivo desse estudo foi avaliar a rugosidade média superficial (Ra) e estabilidade de cor de resinas acrílicas(Lucitone 550, QC-20 e Vipi-Wave), empregadas na confecção de bases para próteses totais, removíveis, overdentures e próteses protocolos sobre implantes após imersão em desinfetantes químicos (hipoclorito de sódio 1% e ácido peracético 2%) por 30 e 60 minutos, e após desinfecção por 30minutos seguida de imersão em bebidas com e sem teor alcóolico (vinho, suco de uva, chá e aguardente). Foram confeccionados 60 corpos-de-prova de cada marca comercial de resina, sendo divididos em 2 grupos, referentes aos desinfetantes químicos. Após os procedimentos de acabamento e polimento dos corpos-de-prova, foram realizadas as mensurações iniciais (t=0) de rugosidade e cor, e a seguir dez corpos-de-prova de cada marca comercial de resina foram imersos em hipoclorito de sódio e dez em ácido peracético, durante 30 e 60 minutos, sendo realizadas as mensurações após cada período de imersão. Esses dados foram, posteriormente submetidos à análise estatística. Quarenta corpos-de-prova de cada tipo de resina foram imersos em hipoclorito de sódio e ácido peracético por 30min, a seguir foram realizadas as mensurações de rugosidade e cor, e a divisão em subgrupos referentes às bebidas. Os corpos-de-prova foram lavados com água destilada, secos com lenços de papel e imersos em vinho(n=5), suco de uva(n=5), chá (n=5) e aguardente (n=5) por 2 horas. Após as mensurações, os corpos-de-prova foram imersos em água destilada e mantidos por 24 horas, decorrido esse período foram realizadas as mensurações de rugosidade e cor. Os corpos-de-prova eram imersos diariamente nas bebidas por 2 horas e as mensurações subseqüentes de rugosidade e cor eram realizadas após 168hs (7dias), 336hs (14dias) e 504hs (21dias) de imersão nas mesmas bebidas.Os dados foram analisados estatisticamente pela Análise de Variância e testes complementares de Tukey e Scheffé. Foi evidenciado aumento da Ra após 30 minutos de imersão nos desinfetantes em todas as resinas, com QC-20 apresentando os maiores valores de Ra e Vipi-Wave os menores. Lucitone 550 apresentou maior Ra após imersão em vinho, suco de uva e aguardente e Vipi-Wave após imersão em chá. Após 60minutos de imersão nos desinfetantes todas as resinas apresentaram alteração de cor estatisticamente significante. Os corpos-de-prova imersos em vinho apresentaram os maiores valores de alteração de cor após 336hs (14dias), enquanto os imersos em suco de uva apresentaram alterações de cor leves após 168hs (7dias), 336hs (14dias) e 504hs (21dias), e os imersos em aguardente e chá não apresentaram alterações de cor clinicamente significantes. Conclui-se que desinfecção em hipoclorito de sódio 1% e ácido peracético alterou as propriedades de rugosidade média e cor das resinas avaliadas, e dentre as bebidas, vinho e suco de uva foram as que propiciaram maior alteração de cor. / Patients submitted to prosthetic procedures are exposed to pathogenic microorganisms, and the development of diseases and crossed infection may occur between patients and the dental team. Dentures must be disinfected with substances that do not cause changes in the mechanical and physical properties, particularly in association with the ingestion of beverages with alcohol concentration or low pH. This study evaluated the surface roughness (Ra) and color stability of acrylic resin colors (Lucitone 550, QC-20 and Vipi-Wave), used for fabricating bases for complete, removable dentures, overdentures and prosthetic protocol after immersion in chemical disinfectants (1% sodium hypochlorite and 2% peracetic acid) for 30 and 60 minutes, and after disinfection, followed by immersion in beverages (wine, grape juice, tea and brandy) for 30minutes. Sixty specimens were made of each commercial brand of resin composite, and divided into 2 groups according to the chemical disinfectants. After the test specimens had undergone the finishing and polishing procedures, the initial color and roughness measurements were taken (t=0), and after this, tem test specimens of each commercial brand of resin composite were immersed in sodium hypochlorite and ten in peracetic acid, for 30 and 60 sixty minutes, with measurements being taken after each immersion period. Afterwards, these data were submitted to statistical analysis. Forty test specimens of each type of resin were immersed in sodium hypochlorite and peracetic acid for 30 min, after which roughness and color measurements were taken, and specimens were divided into subgroups according to the beverages. The specimens were washed with distilled water, dried with paper towels and immersed in wine (n=5), grape juice (n=5), tea (n=5) and brandy (n=5) for 2 hours. After being measured, the test specimens were immersed in distilled water and kept there for 24 hours. When this period elapsed, roughness and color were measured. The test specimens were immersed for 2 hours daily, and the subsequent roughness and color measurements were taken 168 hrs (7days), 336 hrs (14days) and 504 hrs (21days) after immersion in the same beverages. The data were statistically analyzed by the Analysis of Variance and Tukey and Scheffé complementary tests. There was evidence of an increase in Ra after 30 minutes immersion in the disinfectants in all the resins, with QC-20 presenting the highest Ra values, and Vipi-Wave the lowest. The Lucitone 550 resin presented the highest Ra after immersion in wine, grape juice and brandy, and Vipi-Wave after immersion in tea. After 60 minutes immersion in the disinfectants all the resins presented statistically significant color alteration. The test specimens immersed in wine presented the highest color alteration values after 14 days, while those immersed in grape juice presented slight color alterations after 168 hrs (7days), 336hrs (14days) and 504hs (21days), and those immersed in brandy and tea presented no clinically significant color alterations. It was concluded that disinfection in 1% sodium hypochlorite and peracetic acid altered the properties of roughness and color of the evaluated resins, and among the beverages, wine and grape juice were those that produced the greatest color alteration.
|
188 |
Influência da desinfecção química e do tempo de armazenagem sobre as propriedades físicas das próteses oculares /Moreno, Amália. January 2011 (has links)
Orientador: Marcelo Coelho Goiato / Coorientador: Daniela Micheline dos Santos / Banca: Simone Cecílio Hallak Regalo / Banca: Stefan Fiuza Carvalho Dekon / Resumo: As próteses oculares são responsáveis pela recuperação da estética e auto-estima do usuário. Assim, os materiais utilizados na confecção de prótese ocular devem possuir propriedades específicas para sua indicação e durabilidade. Desse modo, é importante avaliar o comportamento destes materiais quando influenciados por diversas soluções desinfetantes. Este estudo teve como objetivo avaliar a microdureza, rugosidade superficial e alteração de cor de próteses oculares sobre a influência da desinfecção química e armazenagem. Foram confeccionadas 50 amostras simulando próteses oculares contendo duas resinas acrílicas (N1 e incolor), distribuídas em cinco grupos de acordo com o desinfetante utilizado: sabão neutro (I), opti-free (II), efferdent (III), hipoclorito a 1% (IV) e clorexidina a 4% (V). As amostras foram armazenadas por 120 dias, sendo desinfetadas durante este período. As leituras de microdureza, rugosidade e cor das amostras foram realizadas em um período inicial (B) e após 60 (T1) e 120 (T2) dias de armazenagem com desinfecção. A microdureza foi mensurada por meio de um microdurômetro, e a rugosidade determinada por um rugosímetro. A leitura de cor foi realizada por meio da espectrofotometria de reflexão, usando o sistema CIE L*a*b*. A alteração de cor (ΔE) foi calculada para os períodos entre T1 e B (T1B), e T2 e B (T2B). Pelos resultados obtidos a resina N1 para esclera apresentou menor microdureza estatisticamente significante, comparada a resina incolor (P<0,05). A maior alteração dos valores de microdureza e rugosidade foi obtida para os grupos IV e V. Ambos os períodos de desinfecção e armazenagem produziram alterações significativas (P<0,05) nas amostras com diminuição dos valores de... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Ocular prostheses are responsible to restore not only patient's aesthetic but also its self-esteem. The materials used to fabricate the ocular prostheses should present specific properties regarding its indication and durability. Therefore, it is important to investigate the physical behavior of such materials when subjected to different disinfectant solutions. This study evaluated the microhardness, surface roughness and color stability of ocular prostheses under the influence of different chemical disinfectant solutions and storage. A total of 50 samples simulating an ocular prosthesis containing two acrylic resins (N1 and colorless) were fabricated. They were divided into five groups as a function of disinfectant solution: neutral soap (I), opti-free (II), efferdent (III), 1% hypochlorite (IV) and 4% chlorhexidine (V). Samples were storage during 120 days, and they were disinfected throughout the period. Microhardness, roughness and color measurements were performed at baseline (B), after 60 (T1) and 120 (T2) days of storage with disinfection. The microharness and the roughness measurements were evaluated using a microdurometer and a roughness meter, respectively. Samples colors were measured with spectrophotometer using CIE L*a*b* system. Color differences (ΔE*) were calculated for periods between T1 and B (T1B), and T2 and B (T2B). The N1 acrylic resin exhibited statistically lower microhardness when compared to the colorless acrylic resin (P<0.05). The highest microhardness and roughness alterations were observed for groups IV and V. Both disinfection and storage periods statistically reduced the microhadness values and increased the roughness values of the samples (P<0.05). Color alteration was... (Complete abstract click electronic access below) / Mestre
|
189 |
Avaliação de propriedades físicas, mecânicas e biológicas de uma resina acrílica para base de próteses após imersão em soluções de sabonetes líquidos desinfetantes : efeito de tempo de imersão /Zoccolotti, Jacqueline de Oliveira January 2017 (has links)
Orientador: Janaina Habib Jorge / Resumo: A desinfecção química associada ao método mecânico tem sido recomendada para a higienização de próteses removíveis parciais ou totais. Levando-se em consideração as desvantagens dos agentes químicos de limpeza utilizados para a desinfecção ou redução do biofilme das próteses, como o manchamento, branqueamento e corrosão das partes metálicas, novos estudos são necessários. Assim, o objetivo deste estudo foi avaliar as propriedades biológicas, físicas e mecânicas de uma resina acrílica para base de próteses após imersão em sabonetes líquidos desinfetantes, nas suas concentrações inibitórias minímas (CIM) para Candida albicans, após diferentes períodos de tempo. Primeiramente, a CIM de cada sabonete foi determinada. Amostras de resina acrílica (Vipi Wave®) foram confeccionadas e divididas em grupos para avaliação da capacidade de formação de biofilme (n=6), citotoxicidade (n=9), rugosidade (n=15), dureza (n=15) e alteração de cor (n=15), após imersão por 0, 7, 14, 21 e 28 dias, nas seguintes soluções: AD: imersão em água destilada a 37°C (grupo controle); SD: ciclos de imersão diária em sabonete Dettol®® a 0,39%, por 8 horas a temperatura ambiente, seguido de imersão em água destilada por 16 horas a 37°C, simulando a desinfecção noturna das próteses; SP: ciclos de imersão diária em sabonete Protex® a 3,12%, conforme descrito para o grupo anterior. SL: ciclos de imersão diária em sabonete Lifebuoy® a 0,78%, conforme descrito para o grupo SD. Além disso, a redução do biofilme de C... (Resumo completo, clicar acesso eletrônico abaixo) / Chemical disinfection associated with the mechanical method has been recommended for the cleaning of partial or full dentures. Taking into consideration the drawbacks of the cleaning chemicals used for disinfection or reduction of biofilm of prostheses, such as staining, bleaching and corrosion of metal parts, further studies are needed. The objective of this study was to evaluate the biological, physical and mechanical properties of an acrylic resin for denture base (Vipi Wave®) after immersion in liquid disinfectant soaps in their minimum inhibitory concentrations (MIC) for Candida albicans, after different periods of time. Samples of acrylic resin (Vipi Wave®) were made. Samples from acrylic resin (Vipi Wave®) were made and shared in groups for the assessment of the biofilm formation capacity (n=6), cytotoxicity (n=9), roughness (n=15), hardness (n=15) and color change (n=15) after immersion in the following solutions for 0, 7, 14, 21 and 28 days: AD: immersion in distilled water at 37 ° C (control group); SD: daily immersion cycles in soap Dettol® 0.39% for 8 hours at room temperature, followed by soaking in distilled water for 16 hours at 37 ° C, simulating the night disinfection of prostheses; SP: daily immersion cycles in soap Protex® to 3.12%, as described for the previous group. SL: daily immersion cycles in Lifebuoy® in soap to 0.78%, as described for the SD group. In soap Dettol® was found the MIC of 0.39% of the soap concentration; in Protex® 3.12% and in Lifebuoy® the MIC was 0.78%. In addition, capacity of reduction of the biofilm of Candida albicans formed on the surface of samples (n = 9) immersed for 8 hours (overnight) in the solutions was also evaluated. To know the biofilm-forming capacity, there were the forming unit count tests of colonies and alamarBlue® ...(Complete abstract electronic access below) / Mestre
|
190 |
Caracterização de materiais experimentais e comerciais para reembasamento imediato por meio de análise de propriedades físico-químicas e mecânicas /Reis, José Mauricio dos Santos Nunes. January 2009 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Renata Cunha Matheus Rodrigues Garcia / Banca: Karin Hermana Neppelenbroek / Banca: João Neudenir Ariolli Filho / Banca: Eunice Teresinha Giampaolo / Resumo: Este estudo avaliou o comportamento exotérmico de 5 resinas rígidas para reembasamento imediato, duas experimentais (E1 e E2) à base de agentes de ligação cruzada (etileno glicol dimetacrilato e 1,4-butanediol dimetacrilato) e três comerciais (Kooliner-K, New Truliner-NT, Tokuyama Rebase II-TR II), bem como o grau de conversão (GC), a sorção (Sor) e a solubilidade (Sol) em água, a contração linear de polimerização (CLP), as propriedades viscoelásticas e a resistência à flexão desses materiais e de uma resina para base de prótese (Lucitone 550-L). Foi avaliada, ainda, a resistência de união (RU) entre os reembasadores e a resina de base. O comportamento exotérmico foi avaliado (n=4) com termopar tipo K inserido no interior das resinas, em matriz circular (60 x 2,0 mm), e mantido até a polimerização. O GC (%) foi avaliado (n=5) por espectroscopia de infravermelho por transformadas de Fourier (32 leituras; resolução 4,0 cm-1). A Sor e a Sol (μg/mm3) foram mensuradas (n=5) seguindo as recomendações da ISO 1567. A CLP (%) foi avaliada (n=10), em projetor de perfil (Nikon 6C), em corpos-de-prova circulares (50 x 0,5 mm). Para avaliar as propriedades viscoelásticas, corpos-de-prova (40 x 10 x 3,3 mm) foram submetidos (n=2) à análise térmica dinâmico-mecânica (DMTA) em diferentes intervalos de temperatura (ciclos). O módulo de armazenamento (E') e o amortecimento mecânico (tan δ) a 37ºC foram registrados durante o primeiro e último ciclo da DMTA. A temperatura de transição vítrea (Tg) foi mensurada somente no último ciclo da DMTA. Os ensaios mecânicos de flexão (0,5 mm/min) foram realizados (n=10) em corpos-de-prova (64 x 10 x 3,3 mm) intactos ou reembasados e a resistência (MPa) calculada na tensão máxima (RFM) e no limite de proporcionalidade (RFLP). Para avaliar a RU (MPa) entre os materiais, 60 cilindros (20 x 20 mm) da resina L foram processados... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the exothermic behavior, degree of conversion (DC), water sorption (WSor), water solubility (WSol), linear polymerization shrinkage (LPS), viscoelastic properties and flexural strength of 5 hard chairside reline resins, two experimental (E1 and E2) based on crosslinking agents (ethylene glycol dimethacrylate and 1,4-butanediol dimethacrylate) and three commercially available (Kooliner-K, New Truliner-NT and Tokuyama Rebase II-TR II), and one heat-polymerized denture base resin (Lucitone 550-L). The shear bond strength (SBS) between the denture base resin and the reline materials was also evaluated. The exothermic behavior of circular specimens (60 x 2.0 mm) during polymerization was assessed (n=4) using a type K thermocouple. The DC (%) was measured (n=5) by Fourier Transformed infrared-attenuated total reflectance (FTIR-ATR) spectroscopy (32 scans; resolution of 4.0 cm-1). WSor and Wsol (μg/mm3) were determined (n=5) according to the recommendation stated in ISO 1567. The LPS (%) was measured (n=10) in circular specimens (50 x 0.5 mm) using a perfilometer (Nikon 6C). The viscoelastic properties of the specimens (40 x 10 x 3.3 mm) were evaluated (n=2) by dynamical-mechanical thermal analysis (DMTA) under different temperature ranges (runs). Values of storage modulus (E') and loss tangent (tan δ) at 37ºC were obtained from the first and last runs. The glass transition temperature (Tg) was only measured from the last run. Ultimate flexural strength (UFS - MPa) and flexural strength at the proportional limit (FSPL - MPa) were determined (n=10) by three-point test (0.5 mm/min) using intact and relined specimens (64 x 10 x 3.3 mm). To evaluate the SBS between the materials, 60 cylinders (20 x 20 mm) of the denture base resin L were processed, relined (3.5 x 5.0 mm) and submitted to shear testing (0.5 mm/min). Data were analyzed by ANOVA and Tukey... (Complete abstract click electronic access below) / Doutor
|
Page generated in 0.06 seconds