• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 79
  • 63
  • 13
  • 3
  • 3
  • 1
  • Tagged with
  • 162
  • 110
  • 84
  • 52
  • 34
  • 30
  • 30
  • 30
  • 29
  • 22
  • 19
  • 16
  • 16
  • 16
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Integral pumping tests for the characterization of groundwater contamination

Bayer-Raich, Martí Unknown Date (has links) (PDF)
University, Diss., 2004--Tübingen.
52

Regionale und substratabhängige Verteilung von Schwermetallen in oberflächennahen Sedimenten des Inner Kingston Basin, Ontariosee / Spatial and Substrate Associated Distribution of Heavy Metals in Surficial Sediments from Inner Kingston Basin, Lake Ontario

Döpke, Gisbert 09 November 2004 (has links)
The sequential extraction scheme BCR 701 has been applied to the upper 2 cm layer of 39 sediment samples from Inner Kingston Basin, Ontario. The samples were also been characterized by water content, loss on ignition at 550°C and 950°C and by particle size distribution. Methodological problems occurred during particle size analysis, caused by agglomerating effects, mainly driven by organic matter, which is fairly resistant against oxidation by hydrogen peroxide due to natural manganese dioxide particles in the sediments. This leads to an overestimation of the clay content. For the same reason, the digestion in step 3 of the sequential extraction was insufficient, so that typical organic bound metals were found in the residual fraction. From factor and cluster analysis of all data three main substrate element associations were derived: The carbonate group contains Ca, Sr, LOI 950°C from calcite, and in step 2 additional Mg extracted from dolomite. Secondly, the organic associations include LOI 550°C, water content and clay content, and finally the metals (except from carbonate bound metals) which are more or less linked to the organic associations. Regionalized maps using inverse distance weighting or ordinary Kriging have been judged to be less precise and informative than point data maps using a classification following equal standard deviation distances and additional statistical information, box plots and histograms. Compared to the geogenic background, all samples show a significant metal enrichment in the mobile fractions, so that they could easily be remobilized during changing environmental conditions. Higher enrichment rates have been detected around the city of Kingston, mainly the harbour region, and close to the outlet of Kingston s sewage treatment plant. Generally, local contamination can easily be detected and differentiated according to their origin from sequential extraction data.
53

Ein digitales Verfahren zur Ultraschall-Laufzeitdifferenzmessung

Maaß, Sebastian 11 August 2023 (has links)
Clamp-On-Sensoren gewinnen bei der Ultraschall-Durchflussmessung am flexiblen Schlauch aufgrund ihrer positiven Eigenschaften zunehmend an Bedeutung. Dem gegenüber stehen invasive Inline-Sensoren, die hinsichtlich der Genauigkeit überlegen sind. Für die Weiterentwicklung von Clamp-On-Sensoren ist eine höhere Genauigkeit der Laufzeitdifferenzschätzung oder eine Veränderung der Sensor-Geometrie notwendig. Letzteres wird als Ansatz im Experimentalteil gegeben. Im Hauptteil wird aus zwei schmalbandigen analytischen Signalen ein digitales Verfahren zur Schätzung der Laufzeitdifferenz im Sub-Abtastbereich mathematisch hergeleitet. Zentrales Element dabei ist die Hilbert-Transformation, die durch einen Hilbert-Transformator mit zwei nicht verschwindenden Koeffizienten approximiert wird. Simulationen und Experimente untermauern das Verfahren.
54

Synthesis and Characterization of Bimetallic Nickel Nanoparticles for the Reverse Water Gas Shift Reaction

Heilmann, Maria Theresia 07 April 2022 (has links)
Eine zentrale Herausforderung des 21. Jahrhunderts ist die Reduktion von Treibhausgasen wie beispielsweise Kohlenstoffdioxid (CO2). Ein vielversprechender Ansatz hierfür ist die katalytische Umsetzung von CO2 zu Synthesegas (CO + H2) über die umgekehrte Wassergas-Shift-Reaktion. Nanopartikel sind ein wichtiges Forschungsgebiet aufgrund ihrer einzigartigen Eigenschaften und vielfältigen Anwendungsmöglichkeiten, einschließlich als Katalysatoren für die umgekehrte Wassergas-Shift-Reaktion. Im Fokus dieser Arbeit steht die Synthese von mono- und bimetallischen Nickel-Nanopartikeln und deren Aktivität für die umgekehrte Wassergas-Shift-Reaktion. Im ersten Teil dieser Arbeit wird das weithin bekannte thermische Reduktionsverfahren zur Herstellung von Nickel-Nanopartikeln vereinfacht und modifiziert. Die monometallischen Nickel-Nanopartikel werden eingehend charakterisiert und der Einfluss der Synthesebedingungen auf die finalen Nanopartikel sowie deren katalytische Aktivität für die Umwandlung von CO2 zu Synthesegas untersucht. In einem zweiten Teil wird das modifizierte Syntheseverfahren auf bimetallische Nickel-Nanopartikel durch Co-Reduktion von Nickel mit entweder Kupfer oder Kobalt übertragen. Die Nanopartikel werden eingehend untersucht und die Kern-Schale-Struktur der Nickel-Kupfer-Nanopartikel wird identifiziert und detailliert charakterisiert. Der Einfluss der Reaktionsparameter auf die finalen Nanopartikel und die Korrelation von Größe, Form und Kupfergehalt der Nanopartikel auf die Aktivität für die umgekehrte Wasser-Gas-Shift-Reaktion werden untersucht. / A great challenge of the 21st century is the minimization of greenhouse gases such as CO2. A promising approach is the catalytic conversion of CO2 to synthesis gas (CO + H2) via the reverse water gas shift reaction. Nanoparticles are an important field of research due to their unique properties and variety of applications including catalysts for the reverse water gas shift reaction. This work focusses on the synthesis of mono- and bimetallic nickel nanoparticles and their activity for the reverse water gas shift reaction. In the first part of this work the wellknown thermal reduction procedure for the preparation of nickel nanoparticles is adapted and simplified. The monometallic nickel nanoparticles are characterized thoroughly and the impact of the synthesis conditions on the final nanoparticles and their catalytic activity for the conversion of CO2 to CO are investigated. In a second part the adapted synthesis procedure is transferred to bimetallic nickel nanoparticles by co-reduction of nickel with either copper or cobalt. The nanoparticles are investigated thoroughly and the core-shell structure of nickel copper nanoparticles is identified and characterized in detail. The impact of the reaction parameters on the final nanoparticles as well as the correlation of size, shape and copper content of the nanoparticles on the activity for the reverse water gas shift reaction is investigated.
55

Combination of Acoustic Levitation and Mass Spectrometry: Method Development and Applications

van Wasen, Sebastian 03 June 2024 (has links)
In den letzten Jahrzehnten wurde das Konzept der grünen und nachhaltigen analytischen Chemie immer wichtiger. Ein wesentlicher Bestandteil besteht darin Chemikalien zu reduzieren und analytische Prozesse zu miniaturisieren. Das Ergebnis ist die Nutzung von kleinen Probenvolumina, welche oft zu Problemen in der Handhabung führen können. Besonders physikalische oder chemische Oberflächeneffekte und Kontaminationen stellen eine Herausforderung dar. Die akustische Levitation ist eine Möglichkeit der berührungslosen Probenhandhabung, d.h. Verunreinigungen und Oberflächenreaktionen sind ausgeschlossen, da die Probe nur mit der umgegebenen Gasphase interagiert. Hier ist eine Kopplung mit analytischen Methoden besonders erstrebenswert. Die vorliegende Arbeit beschreibt die Implementierung von akustischer Levitation in die massenspektrometrische Analyse. Eine Kombination aus einem akustischen Levitator als kontaktloser Probengeber, Infrarot-Laser Desorption und Ionisierung mittels chemischer Ionisation bei Atmosphärendruck (APCI) ermöglichte die quantitative Analyse von verschiedensten pharmazeutischen Wirkstoffen im nanomolaren Bereich. Dieser grundlegende Aufbau wurde in der Folge weiterentwickelt und optimiert, sodass am Ende ein breites Spektrum an Analyten detektiert werden konnte. Zusätzlich wurde ein Trypsin Verdau miniaturisiert und kontaktlos im akustischen Levitator durchgeführt und massenspektrometrisch analysiert. Die Ergebnisse zeigen, dass der Trypsinverbrauch gesenkt werden konnte bei gleichzeitiger Verringerung der Reaktionszeit und Verbesserung der Ausbeuten im Vergleich zum Standard-Verfahren. / In recent decades, the concept of green and sustainable analytical chemistry has become increasingly relevant. The main idea is reducing chemicals and miniaturizing analytical processes. The result is the utilization of small sample volumes, which can often lead to handling problems. Especially physical or chemical surface effects and corresponding contaminations are a major challenge. Acoustic levitation is a possibility for non-contact sample handling, i.e. contamination and surface reactions are excluded, since the sample interacts only with the surrounding gas phase. Here, coupling with analytical methods is particularly desirable. The present work describes the implementation of acoustic levitation in mass spectrometric analyses. A combination of an acoustic levitator as a contactless sample supply, infrared laser desorption and post-ionization via atmospheric pressure chemical ionization (APCI) enabled the quantitative analysis of a wide variety of pharmaceutical agents in the nanomolar range. This basic setup was subsequently further developed and optimized so that a wide range of analytes could be detected. Additionally, a trypsin digestion was miniaturized and performed contactless in the acoustic levitator and analyzed by mass spectrometry. The results demonstrated that trypsin consumption could be reduced while simultaneously reaction time decreased and reaction yields increased compared to the tube method.
56

Pflanzenviren als chemische Plattform für die Nanotechnologie

Tscheuschner, Georg 15 July 2024 (has links)
Die Proteinhülle von Pflanzenviren besteht aus Protein-Untereinheiten, die das Genom des Virus verkapseln und transportieren. Der zugrunde liegende self-assembly-Mechanismus kann für nanotechnologische Anwendungen genutzt werden, indem Fremdmoleküle in den Viren verkapselt werden. Diese sogenannten Virus-ähnlichen Partikel (VLP) können zum Wirkstofftransport in der Krebstherapie, für Gentherapie oder als Kontrastmittel bei bildgebenden Verfahren verwendet werden. Auch die Oberfläche der Proteinhülle kann chemisch oder molekularbiologisch funktionalisiert werden. Ein großer Vorteil von Pflanzenviren ist, dass sie keine Gefahr für den Menschen darstellen und einfach in natürlichen Wirtspflanzen hergestellt werden können. In dieser Arbeit wird am Beispiel des Cowpea Chlorotic Mottle Virus (CCMV) gezeigt, wie diese Nanomaterialien effizient hergestellt und nutzbar gemacht werden können. Im ersten Kapitel wurde eine Affinitätsextraktion basierend auf einem neuen Peptid-Aptamer entwickelt, um das CCMV selektiv aus dem Extrakt der infizierten Pflanze zu isolieren. Das Reinigungsprotokoll wurde validiert und eine finale Reinheit von 98,4% mittels Umkehrphasen-HPLC bestimmt. Im zweiten Kapitel wurden CCMV-VLPs durch rekombinante Expression und anschließende in vitro Assemblierung der Kapsidproteine hergestellt. Die Monodispersität der VLPs wurde durch Transmissionselektronenmikroskopie (TEM) bestätigt. Zusätzlich wurde eine Mutante der CCMV-VLPs hergestellt, die physiologischen Bedingungen standhält und für den Einsatz in vivo geeignet ist. Im dritten Kapitel wurden CCMV und dessen VLPs für nanotechnologische Anwendungen genutzt. Gold-Nanopartikel wurden in CCMV-VLPs verkapselt und im TEM sichtbar gemacht. Das CCMV-Kapsid wurde mit einem Modellpeptid funktionalisiert, um das Potenzial dieses Nanomaterials als chemische Plattform zu demonstrieren. / The protein shell of plant viruses consists of protein subunits that encapsulate and transport the viral genome. The underlying self-assembly mechanism can be utilized for nanotechnological applications by encapsulating foreign molecules within the viruses. These so-called virus-like particles (VLPs) can be used for drug delivery in cancer therapy, gene therapy, or as contrast agents in imaging techniques. Additionally, the surface of the protein shell can be functionalized chemically or via molecular biology techniques. A significant advantage of plant viruses is that they pose no threat to humans and can be easily produced in natural host plants. This work demonstrates how these nanomaterials can be efficiently produced and utilized using the example of Cowpea Chlorotic Mottle Virus (CCMV). In the first chapter, an affinity extraction based on a novel peptide aptamer was developed to selectively isolate CCMV from the extract of the infected plant. The purification protocol was validated, achieving a final purity of 98.4% using reverse-phase HPLC. In the second chapter, CCMV-VLPs were produced through recombinant expression and subsequent in vitro assembly of the capsid proteins. The monodispersity of the VLPs was confirmed by transmission electron microscopy (TEM). Additionally, a mutant of the CCMV-VLPs was produced that withstands physiological conditions and is suitable for in vivo applications. In the third chapter, CCMV and its VLPs were used for nanotechnological applications. Gold nanoparticles were encapsulated within CCMV-VLPs and visualized using TEM. The CCMV capsid was also functionalized with a model peptide to demonstrate the potential of this nanomaterial as a chemical platform.
57

Rational Choice: Einzelbesprechung

Tutić, Andreas 20 September 2024 (has links)
Michael Hechter gilt gemeinhin als ein – wenn nicht der – Doyen der Rational Choice Theorie (im Folgenden: RCT) in der Soziologie. Da es höchst unterschiedliche Vorstellungen darüber gibt, wie sich Annahmen über die Rationalität von Akteuren in der sozialwissenschaftlichen Theoriebildung oder der empirischen Sozialforschung einsetzen lassen, liegt es nahe, sich zu fragen, welche zentralen Merkmale Michael Hechters Variante der RCT auszeichnen. Der 2019 erschienene Band „Rational Choice Sociology. Essays on Theory, Collective Action and Social Order“ bietet eine willkommene Gelegenheit, sich mit seinem Werk und insbesondere seiner Konzeption der RCT auseinanderzusetzen.
58

Ein Beitrag zur Modellierung von Erdreichsonden

Kozak, Wojciech 13 January 2018 (has links)
Die verlässliche Vorhersage der Wärmeentzugsleistungen als auch der Soletemperaturen in den Sonden sind wichtig für deren Auslegung und Betriebsoptimierung. Es ist ebenso wichtig für die Auslegung und Optimierung der Anlagen im versorgten Gebäude. In der vorliegenden Dissertation wurde versucht, durch eine mathematische Weiterentwicklung von Greenschen Funktionen (g-Funktionen) eine präzisere Lösung für Temperaturverteilung im Erdreich infolge des von einer oder mehreren Sonden verursachten Wärmeentzuges mit verschiedenen Randbedingungen im geologischen Untergrund zu erreichen. Hierzu wurden sechs „neue“ g-Funktionen entwickelt, die vertikal variable Wärmeentzüge einzelner Sonden und Sondenfelder, eine Asymmetrie des Wärmeentzuges der Sonde, den Einfluss einer zusätzlichen Grundwasserströmung und den realen, geschichteten Untergrund berücksichtigen. Die mathematischen Modelle des Erdreichs wurden mit Modellen für die Soleströmung und Wärmeübergabe in der Hinterfüllung der Sonde gekoppelt und anschließend auf ein praktisches Betriebsbeispiel angewendet. Die Arbeit enthält ebenfalls umfangreiche Sichtung existierender Modelle sowie deren Anwendung und vergleichende Bewertung der teilweise komplexen Modellansätze.:Formelzeichen und Abkürzungen 1 Einführung 2 Energiequellen und Aufbau der Erdwärmeübertrager 2.1 Quellen der geothermalen Energie 2.2 Aufbau der Erdwärmeübertrager 2.3 Betriebsverhalten von Erdwärmesonden 2.4 Auslegung der Sonden 3 Vorhandene Modelle 3.1 Soleströmung 3.2 Wärmeübergang in den Rohren der Sonde 3.3 Wärmeleitung in der Hinterfüllung 3.4 Erdreichmodellierung – numerisch 3.5 Erdreichmodellierung mit g-Funktionen 4 Weiterentwicklung der analytischen Modelle 5 Anwendungsbeispiele 185 5.1 Ein praktisches Beispiel 5.2 Auswirkung auf die Jahresarbeitszahl 6 Zusammenfassung Literatur A Ableitung der Bohrlochwiderstände B Ableitung der Funktionen für Randbedingungen C Eidesstattliche Erklärung / The design of the ground heat exchangers (GHE) systems demands the precise prediction of their heat output and the brine temperature. The same information is needed for design and optimization of the HVAC systems coupled to GHEs. In the thesis at hand the Green’s functions (g-Functions) have been used to develop the more accurate solutions for the temperature distribution in soil resulting from the heat extraction from one GHE or a field of GHEs. These solutions consist of six novel g-functions that take account of the vertical variation of the extracted heat flux in one GHE or field of GHEs, of the horizontal ground water flow and of the horizontal variation of the soil properties. The models for prediction of the soil temperature have been coupled with models for brine flow and heat transfer in the GHE’s grout and eventually applied to the simulation of the real world object. Additionally, the thesis contains broad review of the known models and their applications as well as the comparative analysis of the complex modelling assumptions.:Formelzeichen und Abkürzungen 1 Einführung 2 Energiequellen und Aufbau der Erdwärmeübertrager 2.1 Quellen der geothermalen Energie 2.2 Aufbau der Erdwärmeübertrager 2.3 Betriebsverhalten von Erdwärmesonden 2.4 Auslegung der Sonden 3 Vorhandene Modelle 3.1 Soleströmung 3.2 Wärmeübergang in den Rohren der Sonde 3.3 Wärmeleitung in der Hinterfüllung 3.4 Erdreichmodellierung – numerisch 3.5 Erdreichmodellierung mit g-Funktionen 4 Weiterentwicklung der analytischen Modelle 5 Anwendungsbeispiele 185 5.1 Ein praktisches Beispiel 5.2 Auswirkung auf die Jahresarbeitszahl 6 Zusammenfassung Literatur A Ableitung der Bohrlochwiderstände B Ableitung der Funktionen für Randbedingungen C Eidesstattliche Erklärung
59

Implementierung der akustischen Levitation in ein Totalanalysesystem

Warschat, Carsten 20 September 2018 (has links)
Als Totalanalysesysteme (TAS) werden Geräte bezeichnet, welche komplette chemische Analysen eigenständig ausführen. Die Einführung solcher Systeme ermöglicht einen effizienteren Arbeitsablauf in Analyselaboren, da beispielsweise die Probenmanipulation, Aufreinigung und die physikalisch-/chemische Analyse automatisiert in einem Arbeitsgang durchgeführt werden können. Die speziellen Mikrototalanalysesysteme benötigen geringere Probemengen im $\mu$L- Bereich. Durch Kontamination, Agglomeration oder einem Verschluss etwaiger Kanäle in mikrofluidischen Totalanalysesystemen kann es zu einem kompletten Systemausfall kommen. Eine Alternative bildet die akustische Levitation, um derartige Störfälle durch gänzlichen Verzicht auf Gefäße und Wandkontakte gezielt zu reduzieren. Damit die akustische Levitation erfolgreich in Mikrototalanalysesystemen Anwendung finden kann, bedarf es der technischen Weiterentwicklung von Analysemethoden und Kopplungstechniken. In der vorliegenden Arbeit wird das Hauptaugenmerk auf die Kopplung von Levitationstechnik und Massenspektrometrie gelegt. Darüber hinaus wurden spektroskopische Experimente durchgeführt, welche auf Totalreflektionen innerhalb der Tropfen beruhen. Die besonders gute Reflektion hängt damit zusammen, dass sich die Phasengrenze zwischen Luft und Flüssigkeit im Schwebezustand durch molekulare Wechselwirkungen ständig erneuert und keine produktionsbedingte raue Oberfläche aufweist. Die Kombination aus automatischer Tropfengenerierung, Spektroskopie sowie der entwickelten Methode zur Ionenerzeugung aus dem Probevolumen und der massenspektrometrischen Analyse bilden die Grundlage eines neuartigen Mikrototalanalysesystems für geringe Probemengen. / As a total analysis system (TAS) an instrument is called which carries out complete chemical analysis procedures independently. The introduction of such systems offers a more efficient workflow in analytical laboratories because the sample manipulation, purification and the actual automated analysis can be carried out in one single operation. Specialized and already existing micro total analysis systems require currently a small amount of sample in the $\mu$L range. Owing to contamination, agglomeration and thus cross-secion reduction of incorporated channels in micro fluidics total analysis systems it can lead to a complete system interruption. Hence, the implementation of acoustic levitation in these systems is interessting alternative in order to avoid such kind of problems by abandoning vessels and wall contacts completely. To ensure acoustic levitation in micro total analysis systems can be successfully applied, technical development of analytical methods and coupling techniques is required. In the present work, the coupling of levitation technology and mass spectrometry is the prioritized topic but, in addition, spectroscopic experiments based on total reflections within the levitated droplet are as well realized in order to gain process insights. The particularly good reflection at the freely levitated droplet's circumference is due to the fact that the phase boundary between air and liquid is renewed by molecular interactions constantly and has no production-related rough surface. The combination of automated droplet generation, spectroscopy as well as the developed method for ion generation from the sample volume and mass spectrometry forms the basis of a novel micro total analysis system for small sample quantities.
60

Charakterisierung eines Cisplatin-DNA-spezifischen Antikörpers und seiner Komplexe mittels massenspektrometrischer Methoden

Ruhe, Lena Maria 24 August 2017 (has links)
Im Mittelpunkt dieser Arbeit stand die Analytik eines monoklonalen Antikörpers, der spezifisch auf Cisplatin-behandelte DNA reagiert und bereits routinemäßig zu diagnostischen Zwecken bei der Krebstherapie mit ebendiesem Zytostatikum eingesetzt wird. Zu diesem Zweck wurden vor allem massenspektrometrische Methoden eingesetzt, um einerseits den genauen Aufbau sowie die Zusammensetzung des Antikörpers zu untersuchen und andererseits die Antigenspezifität einer genaueren Betrachtung zu unterziehen. Mit Hilfe von nano-ESI-MS konnte der Antikörper unter Erhalt der nativen Struktur in der Gasphase analysiert werden. Tandem-MS-Experimente lieferten nicht nur einen Einblick in typische Fragmentierungs-muster, sondern generierten z. T. auch Informationen über die Primärsequenz einiger Bereiche des Antikörpers. Die im Fc-Teil gebundenen Glycanstrukturen, die sowohl für die Struktur als auch die Funktionalität des Antikörpers eine entscheidende Rolle spielen, wurden nach enzymatischer Abspaltung separat mit Hilfe von MALDI-MS analysiert. Die vollständige Antikörpersequenz wurde durch proteolytische Spaltung des Antikörpers, Analytik mittels hochaufgelöster Tandem-MS und anschließendem Vergleich mit Daten aus der Sequenzierung auf DNA-Ebene bzw. bekannten Antikörpersequenzen aus Proteindatenbanken aufgeklärt. Im selben Zug konnten auf Peptidebene eine Vielzahl verschiedener posttranslationaler Modifikationen nachgewiesen werden. Weiterhin konnte gezeigt werden, dass der Antikörper unter Erhalt seiner Struktur und der antigenbindenden Eigenschaften an den Zuckerstrukturen mit einem eigens synthetisierten Metallkomplex markiert werden kann. Die für die Spezifitätsstudie des Antikörpers notwendigen Antigene wurden durch Inkubation synthetischer einzel- und doppelsträngiger DNA-Oligomere mit Cisplatin erzeugt und analysiert. Anschließend wurden die verschiedenen Antikörper-Antigen-Komplexe unter nativen Bedingungen hergestellt und massenspektrometrisch charakterisiert. Um einen Eindruck von der Komplexstabilität zu erhalten wurden zusätzlich MS/MS-Untersuchungen des Komplexes mit der platinierten doppelsträngigen DNA durchgeführt. Wie bei der Analytik des freien Antikörpers konnten auch hier spezifische Fragmente detektiert werden. / The focus of the thesis was the characterization of a monoclonal antibody, which binds specifically to cisplatin-treated DNA and is already used for diagnostic purposes in cancer therapy. The structure and composition of the antibody, as well, as the antigen specificity were investigated by mass spectrometry. Using nano-ESI-MS it was possible to analyse the antibody in its native state. Tandem-MS experiments revealed not only specific antibody fragments but also gave information on the primary structure of the antibody. The Fc-bound glycans that are responsible for antibody structure and functionality, were cleaved enzymatically and studied with MALDI-MS. For a detailed determination of the primary structure, the antibody was proteolysed with different enzymes and analyzed via high resolution Tandem-MS. The data was evaluated by comparism with results from sequence analysis on DNA level and known antibody sequences from protein databases. Simultaneously many different posttranslational modifications were identified. Furthermore, the antibody was successfully labelled with a metal complex at its sugar structures without loss of its structure and function. For investigation of the antibody specificity antigens were generated by incubation of well-defined single and double stranded DNA oligomers with cisplatin. Antibody-antigen-complexes were synthesized and analyzed by mass spectrometry under native conditions. The stability of the complex with double stranded DNA was also investigated by MS/MS-experiments. Thus, it was also possible to determine the specific fragmentation behavior for the complex just as for the free antibody.

Page generated in 0.5768 seconds