• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 32
  • 14
  • 9
  • 4
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 79
  • 13
  • 12
  • 10
  • 9
  • 9
  • 9
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Simulações da SAR em virtude da exposição por tablets operados próximo à cabeça

Ferreira, Juliana Borges January 2016 (has links)
A grande maioria da população mundial está crescentemente exposta à radiação eletromagnética proveniente de fontes que muitas vezes estão localizadas nas proximidades do corpo. A radiação eletromagnética é considerada um agente possivelmente cancerígeno para as pessoas, classificação 2B indicada pela Organização Mundial da Saúde-OMS (WHO/IARC, 2011). Devido às preocupações em relação aos riscos associados a esta exposição existem normas que recomendam os valores máximos de exposição permitidos (ICNIRP, 1998; FCC, 2001). A correta avaliação das doses de radiação é, portanto, relevante. Este trabalho tem a finalidade de avaliar o impacto dos resultados do cálculo da dose da Taxa de Absorção Específica (SAR) em usuários expostos a radiação por tablets operando na faixa de radiocomunicações Wi-fi. Os três modelos existentes de cabeça humana utilizados serão um manequim homogêneo SAM phantom e dois modelos de cabeça realistas heterogêneos: um adulto masculino e uma criança masculina. Será também utilizado nas simulações um modelo masculino de criança que foi desenvolvido através de imagens de tomografia computadorizada (TC) pelo processo de segmentação feito no software AMIRA. Será utilizado um modelo genérico de tablet. Os parâmetros dosimétricos usados para simulação da SAR serão computados pelo software SEMCAD X que é baseado no Método das Diferenças Finitas no Domínio do Tempo (FDTD). Será criado também um código do Método FDTD através do software MATLAB que servirá para a escolha dos parâmetros do SEMCAD X. A distância entre o tablet e os modelos de cabeças varia de 50 mm a 300 mm. Os resultados da SAR serão comparados com os limites de exposição recomendados pelas normas internacionais. Também serão simuladas diferentes posições da antena no tablet. Da análise dos resultados foi constatado que os valores de SAR são muito baixos e todos os resultados ficaram dentro dos limites do psSAR recomendados pela FCC de 1,6 W/kg em cada 1 g de tecido e de 2 W/kg em cada 10 g de tecido estabelecidos pela ICNIRP. Comparando os valores de SAR do modelo SAM com o modelo DUKE, o modelo SAM se mostra conservador, porém quando a comparação é feita com as crianças o SAM deixa de ser conservador. / The vast majority of the world population is increasingly exposed to electromagnetic radiation from sources which are often located near to the body. Electromagnetic radiation is considered a possible carcinogen for people, classification 2B indicated by the World Health Organization-WHO (WHO/IARC, 2011). Due to concerns regarding the risks associated with this exposition there are regulations suggesting maximum allowed exposure values (ICNIRP, 1998; FCC, 2001). The correct evaluation of radiation doses is therefore relevant. This work aims to assess the impact of the results of the calculation of Specific Absorption Rate dose (SAR) in users exposed to radiation from tablets operating in the Wi-fi band. The three existing models of human head used are a homogeneous dummy SAM phantom and two heterogeneous realistic head models: a male adult and a male child. It will also be used in the simulations a male child model which was developed from computed tomography (CT) imaging using the AMIRA software for the segmentation process. A generic model of tablet is used. Dosimetric parameters used for simulation of the SAR are computed using the SEMCAD X software which is based on the Finite Difference Method in Time Domain (FDTD). A FDTD code was developed using the MATLAB software in order to help to choose the input SEMCAD X parameters. The distances between the tablet and the head of the models varies from 50 mm to 300 mm. SAR results are compared with the exposure limits recommended by international standards. Different antenna positions on the tablet are simulated too. Examining the results it was found that the SAR values are very low and all results are within the psSAR limits recommended by FCC (1,6 W/kg averaged over 1 g of tissue) and by ICNIRP (2 W/kg in 10 g of tissue). Comparing the SAR in the SAM model with the SAR in the DUKE model, the SAM model shows to be conservative. However, when compared with the children, the SAM is not conservative.
52

Caracterização das exposições ocupacionais e eficiência da dosimetria pessoal em radiologia intervencionista vascular

Bacchim Neto, Fernando Antonio. January 2017 (has links)
Orientador: Diana Rodrigues Pina / Resumo: A Radiologia Intervencionista (RI) é a área da medicina que proporciona as maiores exposições ocupacionais. Os valores de dose aos quais os intervencionistas são expostos são difíceis de padronizar. Nesta pesquisa apresentamos uma avaliação completa das exposições ocupacionais e determinamos a eficiência de distintos métodos de dosimetria pessoal utilizados na RI. Essa pesquisa foi abordada em 2 etapas, conforme descrito a seguir: A primeira etapa se baseou em caracterizar as exposições ocupacionais em diferentes modalidades de procedimentos de RI vascular para duas categorias de profissionais e estimar o número de procedimentos anuais que cada profissional pode realizar sem exceder os limites de dose. Foi avaliada a exposição ocupacional, através de dosimetria termoluminescente, em diferentes partes do corpo (cristalino, tireoide, tórax, abdômen, pés e mãos) de duas categorias de intervencionistas (principais e assistentes) em três modalidades diferentes de procedimentos de RI vascular. As maiores doses equivalentes foram encontradas para as mão de ambos os profissionais, podendo chegar a aproximadamente 9 mSv em um único procedimento. Algumas regiões dos profissionais em alguns procedimentos podem receber, durante o ano, níveis de doses perigosamente perto dos limites anuais. Dosímetros posicionados no tórax podem subestimar as doses para outras regiões do corpo, especialmente abdômen, extremidades e cristalinos. Na segunda etapa foram avaliadas as eficiências de 6 diferent... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Interventional Radiology (IR) is the area of medicine that provides the largest occupational exposures. The dose values to which interventionists are exposed are difficult to standardize. In this research we present a complete evaluation of occupational exposures and determine the efficiency of different personal dosimetry methods used in IR. This research was performed in 2 stages, as described below: The first step was to characterize the occupational exposures in different modalities of vascular IR procedures for two categories of professionals. We also estimated the number of annual procedures that each professional can perform without exceeding the dose limits. Occupational exposures were evaluated in different body parts (crystalline, thyroid, thorax, abdomen, feet and hands) by two interventional categories (primary and assistants) in three different modalities of vascular IR procedures. The highest equivalent doses were found for the hands of both professionals, reaching approximately 9 mSv in a single procedure. Some regions of professionals in some procedures may receive dose levels during the year dangerously close to annual limits. Dosimeters positioned in the chest may underestimate the doses to other regions of the body, especially the abdomen, extremities and crystalline. The second stage, we evaluated the efficiencies of 6 different personal dosimetry methodologies used internationally to estimate the effective dose received by interventional professionals. An... (Complete abstract click electronic access below) / Mestre
53

Safety belts in lifeboats : evaluation and dynamic tests for improved launch safety /

Hansson, Anders. Stolt, Andreas. January 2002 (has links) (PDF)
Thesis (M.S.)--Kungl. Tekniska högskolan, 2002. / Includes bibliographical references (p. 125-126). Also available online via the Swedish National Road and Transport Research Institute web site (www.vti.se).
54

Simulações da SAR em virtude da exposição por tablets operados próximo à cabeça

Ferreira, Juliana Borges January 2016 (has links)
A grande maioria da população mundial está crescentemente exposta à radiação eletromagnética proveniente de fontes que muitas vezes estão localizadas nas proximidades do corpo. A radiação eletromagnética é considerada um agente possivelmente cancerígeno para as pessoas, classificação 2B indicada pela Organização Mundial da Saúde-OMS (WHO/IARC, 2011). Devido às preocupações em relação aos riscos associados a esta exposição existem normas que recomendam os valores máximos de exposição permitidos (ICNIRP, 1998; FCC, 2001). A correta avaliação das doses de radiação é, portanto, relevante. Este trabalho tem a finalidade de avaliar o impacto dos resultados do cálculo da dose da Taxa de Absorção Específica (SAR) em usuários expostos a radiação por tablets operando na faixa de radiocomunicações Wi-fi. Os três modelos existentes de cabeça humana utilizados serão um manequim homogêneo SAM phantom e dois modelos de cabeça realistas heterogêneos: um adulto masculino e uma criança masculina. Será também utilizado nas simulações um modelo masculino de criança que foi desenvolvido através de imagens de tomografia computadorizada (TC) pelo processo de segmentação feito no software AMIRA. Será utilizado um modelo genérico de tablet. Os parâmetros dosimétricos usados para simulação da SAR serão computados pelo software SEMCAD X que é baseado no Método das Diferenças Finitas no Domínio do Tempo (FDTD). Será criado também um código do Método FDTD através do software MATLAB que servirá para a escolha dos parâmetros do SEMCAD X. A distância entre o tablet e os modelos de cabeças varia de 50 mm a 300 mm. Os resultados da SAR serão comparados com os limites de exposição recomendados pelas normas internacionais. Também serão simuladas diferentes posições da antena no tablet. Da análise dos resultados foi constatado que os valores de SAR são muito baixos e todos os resultados ficaram dentro dos limites do psSAR recomendados pela FCC de 1,6 W/kg em cada 1 g de tecido e de 2 W/kg em cada 10 g de tecido estabelecidos pela ICNIRP. Comparando os valores de SAR do modelo SAM com o modelo DUKE, o modelo SAM se mostra conservador, porém quando a comparação é feita com as crianças o SAM deixa de ser conservador. / The vast majority of the world population is increasingly exposed to electromagnetic radiation from sources which are often located near to the body. Electromagnetic radiation is considered a possible carcinogen for people, classification 2B indicated by the World Health Organization-WHO (WHO/IARC, 2011). Due to concerns regarding the risks associated with this exposition there are regulations suggesting maximum allowed exposure values (ICNIRP, 1998; FCC, 2001). The correct evaluation of radiation doses is therefore relevant. This work aims to assess the impact of the results of the calculation of Specific Absorption Rate dose (SAR) in users exposed to radiation from tablets operating in the Wi-fi band. The three existing models of human head used are a homogeneous dummy SAM phantom and two heterogeneous realistic head models: a male adult and a male child. It will also be used in the simulations a male child model which was developed from computed tomography (CT) imaging using the AMIRA software for the segmentation process. A generic model of tablet is used. Dosimetric parameters used for simulation of the SAR are computed using the SEMCAD X software which is based on the Finite Difference Method in Time Domain (FDTD). A FDTD code was developed using the MATLAB software in order to help to choose the input SEMCAD X parameters. The distances between the tablet and the head of the models varies from 50 mm to 300 mm. SAR results are compared with the exposure limits recommended by international standards. Different antenna positions on the tablet are simulated too. Examining the results it was found that the SAR values are very low and all results are within the psSAR limits recommended by FCC (1,6 W/kg averaged over 1 g of tissue) and by ICNIRP (2 W/kg in 10 g of tissue). Comparing the SAR in the SAM model with the SAR in the DUKE model, the SAM model shows to be conservative. However, when compared with the children, the SAM is not conservative.
55

Simulações da SAR em virtude da exposição por tablets operados próximo à cabeça

Ferreira, Juliana Borges January 2016 (has links)
A grande maioria da população mundial está crescentemente exposta à radiação eletromagnética proveniente de fontes que muitas vezes estão localizadas nas proximidades do corpo. A radiação eletromagnética é considerada um agente possivelmente cancerígeno para as pessoas, classificação 2B indicada pela Organização Mundial da Saúde-OMS (WHO/IARC, 2011). Devido às preocupações em relação aos riscos associados a esta exposição existem normas que recomendam os valores máximos de exposição permitidos (ICNIRP, 1998; FCC, 2001). A correta avaliação das doses de radiação é, portanto, relevante. Este trabalho tem a finalidade de avaliar o impacto dos resultados do cálculo da dose da Taxa de Absorção Específica (SAR) em usuários expostos a radiação por tablets operando na faixa de radiocomunicações Wi-fi. Os três modelos existentes de cabeça humana utilizados serão um manequim homogêneo SAM phantom e dois modelos de cabeça realistas heterogêneos: um adulto masculino e uma criança masculina. Será também utilizado nas simulações um modelo masculino de criança que foi desenvolvido através de imagens de tomografia computadorizada (TC) pelo processo de segmentação feito no software AMIRA. Será utilizado um modelo genérico de tablet. Os parâmetros dosimétricos usados para simulação da SAR serão computados pelo software SEMCAD X que é baseado no Método das Diferenças Finitas no Domínio do Tempo (FDTD). Será criado também um código do Método FDTD através do software MATLAB que servirá para a escolha dos parâmetros do SEMCAD X. A distância entre o tablet e os modelos de cabeças varia de 50 mm a 300 mm. Os resultados da SAR serão comparados com os limites de exposição recomendados pelas normas internacionais. Também serão simuladas diferentes posições da antena no tablet. Da análise dos resultados foi constatado que os valores de SAR são muito baixos e todos os resultados ficaram dentro dos limites do psSAR recomendados pela FCC de 1,6 W/kg em cada 1 g de tecido e de 2 W/kg em cada 10 g de tecido estabelecidos pela ICNIRP. Comparando os valores de SAR do modelo SAM com o modelo DUKE, o modelo SAM se mostra conservador, porém quando a comparação é feita com as crianças o SAM deixa de ser conservador. / The vast majority of the world population is increasingly exposed to electromagnetic radiation from sources which are often located near to the body. Electromagnetic radiation is considered a possible carcinogen for people, classification 2B indicated by the World Health Organization-WHO (WHO/IARC, 2011). Due to concerns regarding the risks associated with this exposition there are regulations suggesting maximum allowed exposure values (ICNIRP, 1998; FCC, 2001). The correct evaluation of radiation doses is therefore relevant. This work aims to assess the impact of the results of the calculation of Specific Absorption Rate dose (SAR) in users exposed to radiation from tablets operating in the Wi-fi band. The three existing models of human head used are a homogeneous dummy SAM phantom and two heterogeneous realistic head models: a male adult and a male child. It will also be used in the simulations a male child model which was developed from computed tomography (CT) imaging using the AMIRA software for the segmentation process. A generic model of tablet is used. Dosimetric parameters used for simulation of the SAR are computed using the SEMCAD X software which is based on the Finite Difference Method in Time Domain (FDTD). A FDTD code was developed using the MATLAB software in order to help to choose the input SEMCAD X parameters. The distances between the tablet and the head of the models varies from 50 mm to 300 mm. SAR results are compared with the exposure limits recommended by international standards. Different antenna positions on the tablet are simulated too. Examining the results it was found that the SAR values are very low and all results are within the psSAR limits recommended by FCC (1,6 W/kg averaged over 1 g of tissue) and by ICNIRP (2 W/kg in 10 g of tissue). Comparing the SAR in the SAM model with the SAR in the DUKE model, the SAM model shows to be conservative. However, when compared with the children, the SAM is not conservative.
56

Mão de São Carlos, uma prótese multifunção para membros superiores: um estudo dos mecanismos, atuadores e sensores / São Carlos hand, a multifunction upper limb prosthesis: a study of the mechanisms, actuators and sensors

Fransérgio Leite da Cunha 26 April 2002 (has links)
Esta tese de Doutorado busca contribuir na formação de subsídios científicos tanto para o projeto de uma prótese antropomórfica para membros superiores, quanto para a criação de um ambiente de treinamento, ou seja, um ambiente virtual de ação e realimentação das sensações, que poderá incorporar os mecanismos, atuadores, sensores ou estimuladores desenvolvidos. Ao final desta pesquisa, foram projetados e testados os mecanismos, sensores e alguns dispositivos de realimentação que farão parte do desenvolvimento de uma prótese de mão, a Mão de São Carlos, que possuirá características antropomórficas, para reproduzir os movimentos naturais da mão humana com um controle simplificado para o paciente. A motivação principal deste trabalho é diminuir o índice de rejeição das próteses para membros superiores, facilitando seu processo de treinamento e controle / This Doctoral thesis should contribute to the gathering of scientific subsidies for the project of a multifunction anthropomorphic upper limb prosthesis, in special the artificial hand, and for the creation of a training software, i.e., a software for the sensory's action and feedback. At the end of this research, the mechanisms, sensors, actuators and some feedback devices were designed and tested, that will be part of the development of a hand prosthesis, the São Carlos Hand, which will possess anthropomorphic characteristics, a simplified control for the patient and will reproduce the natural movements of the human hand. The main motivation of this work is to reduce the rejection index of the upper limb prosthesis, facilitating training process and control
57

Los vasos-efigie antropomorfos: un ejemplo de la orfebrería de la costa central durante el Periodo Intermedio Tardío y el Horizonte Tardío

Carcedo, Paloma, Vetter, Luisa, Diez Canseco, Magdalena 10 April 2018 (has links)
Anthropomorphic Effigy Vases: A Silvermith’s Production during the Late Intermediate Period and Late HorizonAnthropomorphic effigy vases have been classified, without any scientific basis, as belonging to the Chimu Culture. This investigation shows how these kinds of vases are more related in iconography as well as in provenance with the iconography of the central coast of Peru. In a selection of nine vases analysed, we determine different techniques of manufacture, which indicate the high technological complexity achieved by the precolumbian metal smiths during the Late Intermediate period and the Late Horizon. This study seeks to clarify, with the help of historic and ethnographic documentation, the social importance of the silversmith’s workshops that elaborated the effigy vases in question. We hope through the study of these archaeological remains and their comparison with historical texts, to decipher the symbolic and ritual value, as well as possible religious influences in their manufacture along the Peruvian coast. Finally, the possible process used by the coastal metal smiths in the manufacture of the effigy vases was identified by means of electronic microscope and metalographic analysis. / Desde hace mucho tiempo, un tipo especial de objetos rituales —los vasos-efigie antropomorfos de metal— han sido clasificados, sin sustento científico, como pertenecientes a la cultura Chimú. La investigación llevada a cabo por las autoras demuestra cómo este tipo de vasos está más relacionado, tanto en iconografía como en procedencia, con la temática iconográfica de la costa central del Perú. Se trata de un corpus de nueve vasos analizados con el que se determinaron diferentes técnicas de manufactura que muestran la alta complejidad tecnológica lograda por los orfebres tanto en el Periodo Intermedio Tardío como en el Horizonte Tardío. Para la realización de dicha investigación se ha utilizado documentación tanto histórica como etnográfica, las que permitieron explicar la posible importancia social de los talleres de los orfebres o plateros que manufacturaron dichos vasos. Estudios comparativos entre los restos arqueológicos con textos históricos ayudaron a descifrar el valor simbólico o ritual para el que fueron elaborados y su posible influencia religiosa en otros lugares de la costa peruana. Por último, los análisis metalográficos y microscopía electrónica identificaron las posibles formas de manufactura utilizadas en estos vasos por los antiguos orfebres o plateros de la costa.
58

Validation and Repeatability Testing of a New Hybrid III 6-year-old Lower Extremity

Ryu, Yeonsu 30 August 2016 (has links)
No description available.
59

Dei Fide: a relational theology of the faith of God

Holtzen, William Curtis 30 November 2007 (has links)
Relational theology became a major voice in the theological conversations of the twentieth century and now in the twenty-first century it is poised to become the major influence in doctrine of God discussions. Relational theology argues for a model of God that emphasizes a dynamic interaction between God and the cosmos. Reformulating the divine nature contra Classical theism, Relational theology instead includes images of God as sympathetic, mutable, limited in power and knowledge, creative, and as a risk-taker. The assertion is that such images or metaphors for the divine are necessary rightly to understand and discuss God's relationality with the world. This thesis argues that given the relational nature of God the metaphor of faith should be added to the list of God's attributes. The thesis begins by discussing issues of methodology then reviewing Relational theology in the forms of process and open theism as contrasted with Classical theism. This is followed by explorations of various depictions of faith as found in the Old Testament and New Testament. Faith is also examined theologically and philosophically as including the elements of belief, trust, hope, and risk. It is then argued that faith has a decidedly relational nature in that faith most properly takes place between persons. The crux of the thesis is the development of a theology of divine faith. Because humans are free, God is limited, and creation has a purpose, the argument is made that God relates to the world through faith. A case for God's faith is developed exegetically and logically through explorations of the concepts of divine belief, trust, hope, risk, and doubt, concluding that faith is a necessary inclusion for Relational theology. Finally, two primary Church doctrines, creation and christology, are explored through a theology of divine faith. God demonstrates divine faith in bestowing an evolving creation with both freedom and a purpose. God has faith in the creation to produce persons who can freely share faith and love with God. The fully kenotic coming of Jesus Christ demonstrates the Father's faith in the Son, the second person of the triune God. The coming and death of Christ also reveals God's faith that the cross will be efficacious in reconciling those who have abused their God-given freedoms. / Sysytematic Theology & Theological Ethics / D. Th. (Systematic Theology)
60

Desenvolvimento de phantom antropom?rfico cerebral para simula??o de atividade ICTAL e imterictal utilizando a metodologia pet com fl?or-18

Silbermann, Karina Nique Franz 27 August 2018 (has links)
Submitted by PPG Medicina e Ci?ncias da Sa?de (medicina-pg@pucrs.br) on 2018-12-11T14:10:12Z No. of bitstreams: 1 KARINA NIQUE FRANZ SILBERMANN.pdf: 24305952 bytes, checksum: 2707c9d644d7f53ccbd72659a1adda31 (MD5) / Approved for entry into archive by Sheila Dias (sheila.dias@pucrs.br) on 2018-12-13T18:40:06Z (GMT) No. of bitstreams: 1 KARINA NIQUE FRANZ SILBERMANN.pdf: 24305952 bytes, checksum: 2707c9d644d7f53ccbd72659a1adda31 (MD5) / Made available in DSpace on 2018-12-13T19:18:32Z (GMT). No. of bitstreams: 1 KARINA NIQUE FRANZ SILBERMANN.pdf: 24305952 bytes, checksum: 2707c9d644d7f53ccbd72659a1adda31 (MD5) Previous issue date: 2018-08-27 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / The equipment and processes used in nuclear medicine must be included in a quality control program that includes a series of tests and calibrations following the frequency established by current standards, which are based on international institutions protocols. The capability of anthropomorphic simulators mimic realistic situations are widely appointed to gauge essential data that guarantee the quality in medical generating processes. The purpose of this study was developing a cerebral anthropomorphic phantom for image simulation of ictal activity in nuclear medicine with 18F, PET-CT. It was made in an industrial printer with SLS (Selective Laser Sintering) technology, 4mm thick, using nylon 12. The model was segmented from a magnetic resonance study of a 40-year-old female adult. Two 40 nm thickness metal (Ag) electrodes were inserted in the right frontal lobe region to simulate ictal activity. For the images acquisition, the phantom was filled with distillated water and the 18F radioisotope. The images were acquired in PET-CT equipment with specific protocol for tomographic and dynamic cerebral studies. Images from the simulator without the insertion of the electrodes were acquired as pattern (basal), also were acquired images from the simulator with the electrodes and without electric field application, and the simulator with electric field application. The images were compared through SUV maximum values and uptake index. The non-parametric Wilcoxon-Mann-Whitney test was used as statistic approach, considering the three image conditions as independent groups. There was significant difference amongst the groups, being p < 0,001 when compared the average SUV maximum values by slices in the situations: basal x with electric field, and basal x without electric field, p = 0,129 when compared situations with electric field x without electric field, suggesting that this difference is not significant. All the groups presented significant differences for the uptake indexes obtained, being p < 0,001 in the situations basal x with electric field and basal x without electric field. The TAC (time-activity-curve) curves were obtained in A PET-CT dynamic protocol to demonstrate the 18F uptake in time, in the conditions with electric field and without electric field. The images were subtracted through SISCOM, using the basal condition as reference. The values found for p (SUV and uptake index) are compatible. The SISCOM histograms demonstrate differences for the three image comparisons. Although there are gradual raise of 18F uptake in time obtained in TAC evaluation for both with and without electric field conditions, the highest uptake visualized was when the electric field is applied. The anthropomorphic phantom developed is capable of simulating compatible zones with ictal activity, however the material used as resin in the electrodes must be modified so that the product may be commercialized in the future. / Os equipamentos e processos utilizados em medicina nuclear devem estar inclu?dos em um programa de controle de qualidade, o que inclui uma s?rie de testes e calibra??es com periodicidade estabelecida pelas normas vigentes, baseadas nos protocolos de institui??es internacionais. Os simuladores antropom?rficos, pela sua capacidade de mimetizar situa??es real?sticas, s?o amplamente empregados para aferir dados essenciais que garantam a qualidade nos processos geradores de imagens m?dicas. O objetivo deste trabalho foi desenvolver um phantom antropom?rfico cerebral para simula??o de imagens de atividade ictal em medicina nuclear, utilizando metodologia PET com Fl?or-18 (18F). O phantom foi confeccionado em impressora industrial com tecnologia SLS (Selective Laser Sintering), de espessura de 4 mm, utilizando como mat?ria prima nylon 12. O modelo foi segmentado a partir de um estudo de resson?ncia magn?tica de um adulto normal, do sexo feminino, com 40 anos. Para a simula??o de atividade ictal foram inseridos, na regi?o correspondente ao lobo frontal direito, dois eletrodos met?licos constitu?dos de filme fino de 40 nm de prata (Ag). Para a aquisi??o das imagens, o modelo foi preenchido com ?gua destilada e com o radiois?topo 18F. As imagens foram adquiridas em equipamento de PET-CT com protocolo espec?fico para estudos cerebrais tomogr?fico e din?mico. Foram adquiridas imagens: (1) simulador sem a inser??o dos eletrodos (padr?o/basal), (2) simulador com eletrodos sem aplica??o de campo el?trico e (3) simulador com os eletrodos e aplica??o de campo el?trico. As imagens foram comparadas entre si atrav?s dos valores de SUV m?ximo e do ?ndice de capta??o. A abordagem estat?stica utilizada considerou as tr?s condi??es de imagens como grupos independentes e o teste n?o param?trico de Wilcoxon-Mann-Whitney foi aplicado. Houve diferen?a significativa entre os grupos, sendo o valor de p < 0,001 quando comparados os valores de m?dia de SUV m?ximo por corte nas situa??es basal x sem campo el?trico e basal x com campo el?trico. Na compara??o sem campo el?trico x com campo el?trico, o valor de p = 0,129 indica que a diferen?a entre os grupos n?o ? significativa. Quando avaliado o ?ndice de capta??o entre os grupos, todas as condi??es apresentaram diferen?a significativa, sendo p < 0,001 para os grupos basal x sem campo el?trico e basal x com campo el?trico, e p = 0,0123 na compara??o sem campo el?trico x com campo el?trico. As curvas TAC (time-activity-curve) foram adquiridas para demonstrar a capta??o de 18F no tempo, nas condi??es com campo el?trico e sem campo el?trico, em estudo din?mico de PET-CT. As imagens foram subtra?das atrav?s da metodologia SISCOM, utilizando a condi??o basal como refer?ncia. Os valores encontrados para p, tanto para SUV como para ?ndice de capta??o, s?o compat?veis com os achados visualizados nas imagens obtidas. Os histogramas gerados com a metodologia SISCOM demonstram que h? diferen?as entre as tr?s condi??es de imagem. As curvas TAC tra?adas correspondem ao aumento gradativo da concentra??o 18F no tempo, embora exista este aumento nas condi??es sem campo e com campo, obtivemos a maior concentra??o quando o sistema est? sob efeito do campo el?trico. O phantom antropom?rfico desenvolvido ? capaz de simular zonas an?logas ?s de imagens de atividade ictal, por?m o material utilizado como resina nos eletrodos deve ser modificado para que o produto possa ser comercializado futuramente.

Page generated in 0.0669 seconds