Mesure du rapport d'embranchement et du facteur de forme de la désintégration B⁰ → π⁻l⁺v, et détermination de |V[exposant]u[exposant]b| avec une technique de reconstruction relâchée du neutrino

Côté, David January 2007 (has links)
Thèse diffusée initialement dans le cadre d'un projet pilote des Presses de l'Université de Montréal/Centre d'édition numérique UdeM (1997-2008) avec l'autorisation de l'auteur.
2

Mesure du rapport d'embranchement et du facteur de forme de la désintégration B⁰ → π⁻l⁺v, et détermination de |V[indice]u[indice]b| avec une technique de reconstruction relâchée du neutrino

Côté, David January 2007 (has links)
No description available.
3

Étude de la concordance d'un univers de Dirac-Milne symétrique matière-antimatière

Benoit-Lévy, Aurélien 18 September 2009 (has links) (PDF)
Cette thèse s'intéresse à divers aspects de l'univers de Dirac-Milne, un modèle cosmologique dans lequel matière et antimatière sont présentes en quantités égales et où l'on suppose, comme pourrait le suggérer la relativité générale à travers les propriétés des solutions de Kerr-Newman, que l'antimatière possède une masse gravitationnelle active négative. Ces hypothèses permettent de s'affranchir de la nécessité d'introduire Inflation, Énergie Noire et Matière Noire, dont les mises en évidences expérimentales et les motivations théoriques font parfois défaut. La présence en quantités égales de matière de masse positive et d'antimatière de masse négative impose une évolution du facteur d'expansion linéaire par rapport au temps. Après avoir rappelé les concepts basiques de la cosmologie, certaines implications de cette évolution linéaire sont étudiées. L'étude complète de la nucléosynthèse primordiale dans le cadre de ce modèle alternatif permet de montrer qu'une production primordiale de deutérium est rendue possible par la présence d'annihilations résiduelles entre matière et antimatière à des époques précédant la recombinaison. Toutefois, ce mécanisme de production secondaire conduit à une surproduction d'hélium-3, potentiellement incompatible avec les observations. Bien que l'univers de Dirac-Milne ne présente pas d'accélération de l'expansion aux époques récentes, il est montré que ce modèle satisfait raisonnablement bien au test cosmologique des supernovae de type Ia. De même, l'échelle angulaire du premier pic acoustique des fluctuations de température du fond diffus cosmologique apparaît naturellement à l'échelle du degré. Même si l'étude complète du spectre de ces fluctuations et de la cohérence de la notion de masse négative reste encore à approfondir, ce travail pose les bases d'un modèle cosmologique original et potentiellement capable de donner une autre description de notre Univers.
4

Déflectométrie Moiré d’Ions de Basse Énergie pour l’Expérience AEGIS / Moiré Deflectometry with a Low-Energy Ion Beam for the AEGIS Experiment

Lansonneur, Pierre 05 October 2017 (has links)
Bien que les propriétés de l'antimatière soit largement testées dans le secteur faible, fort et électromagnétique, la question de la gravitation pour ces objets reste ouverte. En observant la chute libre d'atomes d'anti-hydrogène, l'expérience AEGIS prévoit de mesurer pour lapremière fois l'accéleration gravitationelle pour l'antimatière. Le dispositif prévu pour cette mesure se compose de trois réseaux en transmission et d'un détecteur possèdant une haute résolution spatiale. Le travail de cette thèse se concentre sur la caractérisation d'un tel dispositif avec une source d'ions de basse énergie, permettant de mesurer simultanément les champs électriques et magnétiques environnant. La sensibilité atteinte en font un dispositif compétitif avec les meilleurs appareils disponibles. Une attention particulière est également portée sur l'implémentation de l'expérience avec des réseaux de pas plus fin, afin de mettre en évidence l'interférence quantique des ions. Les effets qui pourraient réduire le contraste des franges d'interférences sont passés en revue et discutés. Enfin, la réalisation d'une ligne de faisceau capable de sélectionner des particules de basse énergie et l'intégration d'un détecteur silicium dédié à la détection d'antiprotons est détaillée dans le but de réaliser pour la première fois l'interférence de particules d'antimatière / Although numerous experiments investigate the properties of antimatter in the weak, strong and electromagnetic sector, the gravitational interaction for these objects remains an open question. By observing the free-fall of antihydrogen atoms, the AEGIS experiment plans toperform the first measurement of the gravitational acceleration on antimatter. The device envisioned for such an experiment consists in a set of three transmission gratings with a pitch of few micrometers, associated with a high resolution imaging detector. This thesis focuses on testing such a device with a low-energy ion beam, enabling one to measure simultaneously the magnitude of surrounding electric and magnetic fields. The sensitivity achieved makes such an apparatus competitive with state-of-the-art fieldmeters. An effort is moreover initiated to perform the same experiment with smaller grating periodicities since it could reveal the quantum interference of the ions. In order to probe the quantum behavior of protons, the effects which might destroy the interference pattern are reviewed and discussed. We finally detail the implementation of a velocity selector and a silicon detector dedicated to low energy antiprotons. These two components are indeed a prerequisite to perform for the first time theinterference of antimatter particles
5

Piégeage et accumulation de positons issus d’un faisceau pulsé produit par un accélérateur pour l’étude de l’interaction gravitationnelle de l’antimatière / Trapping and accumulation of positrons from a pulsed beam produced by a linear accelerator for gravitationnal interaction of antimatter study.

Grandemange, Pierre 12 December 2013 (has links)
L'expérience GBAR - Gravitational Behaviour of Antihydrogen at Rest - est conçue pour réaliser un test direct du principe d'équivalence faible sur l'antimatière. Son objectif est de mesurer l'accélération d'un antiatome d'hydrogène en chute libre, appelée Gbar. Son originalité réside dans la production d'antiions Hbar+ pour appliquer le refroidissement sympathique afin d'obtenir une température de l'ordre du µK, indispensable à la réalisation de la mesure. Les ions Hbar+ sont produits par les réactions : pbar + Ps -> Hbar + e-, puis Hbar + Ps -> Hbar+ + e-, où pbar représente l'antiproton, Ps le positronium (l'état lié entre le positon et l'électron), Hbar l'antihydrogène et Hbar+ l'antiion associé. Pour produire la quantité de Ps nécessaire à l'expérience GBAR, 2x10^10 positons doivent être injectés sur une cible mésoporeuse de SiO2 en moins de 100ns. Un tel flux nécessite l'accumulation et le refroidissement des positons dans un piège à particules.Cette thèse décrit l'injecteur de positons en phase de démonstration à Saclay pour l'expérience GBAR. Il est constitué d'un piège de Penning-Malmberg (emprunté au laboratoire du RIKEN) alimenté par un faisceau de positons lents. Un accélérateur linéaire d'électrons de 4.3MeV produit le faisceau pulsé de positons en tirant sur une cible de tungstène, modéré ensuite par un modérateur constitué de multiples couches de grilles de tungstène. Le flux de positons lents est de 10^4 e+/pulse, soit 2x10^6 e+/s à 200Hz. Nous présentons dans ce document la toute première accumulation de positons produit par un accélérateur (plutôt qu'une source radioactive), et leur refroidissement dans un plasma de 2x10^10 électrons préalablement chargés dans le piège. / The Gravitational Behaviour of Antihydrogen at Rest experiment - GBAR - is designed to perform a direct measurement of the weak equivalence principle on antimatter by measuring the acceleration (gbar) of antihydrogen atoms in free fall. Its originality is to produce Hbar+ ions and use sympathetic cooling to achieve µK temperature. Hbar+ ions are produced by the reactions : pbar + Ps -> Hbar + e-, and Hbar + Ps -> Hbar+ + e-, where pbar is an antiproton, Ps stands for positronium (the bound-state of a positron and an electron), Hbar is the antihydrogen and Hbar+ the antiion associated. To produce enough Ps atoms, 2x10^10 positrons must be impinged on a porous SiO2 target within 100ns. Such an intense flux requires the accumulation (collection and cooling) of the positrons in a particle trap. This thesis describes the injector being commissioned at CEA Saclay for GBAR. It consists of a Penning-Malmberg trap (moved from RIKEN) fed by a slow positron beam. A 4.3MeV linear accelerator shooting electrons on a tungsten target produces the pulsed positron beam, which is moderated by a multi-grid tungsten moderator. The slow positron flux is 10^4 e+/pulse, or 2x10^6 e+/s at 200Hz. This work presents the first ever accumulation of low-energy positrons produced by an accelerator (rather than a radioactive source) and their cooling by a prepared reservoir of 2x10^10 cold electrons.
6

Production et propagation de noyaux légers d'antimatière dans la galaxie

Duperray, Rémy 08 July 2004 (has links) (PDF)
La présente thèse porte sur le calcul des flux d'antimatière d'origine galactique, sous forme d'antiprotons, d'antideuterons, d'antihélium 3 et d'antihélium 4, attendus au niveau de la Terre et produits par interaction du rayonnement cosmique (RC) avec la matière du milieu interstellaire. Cette antimatière qualifiée de secondaire, constitue un bruit de fond pour la recherche d'antimatière d'origine primordiale (issue d'antigalaxies) dans le RC ainsi que pour la recherche d'antimatière produite par des sources exotiques: matière noire (par annihilation de particules massives comme le neutralino) et trous noirs primordiaux (par évaporation). Une évaluation aussi précise que possible de ce bruit de fond s'avère nécessaire au vu de la mise en œuvre dans les années à venir de spectromètres spatiaux (AMS) conçus pour traquer l'antimatière dans le RC Notre nouvelle estimation du flux d'antiproton est en accord avec les précédents calculs même si des différences existent, provenant en particulier de l'utilisation de sections efficaces de production d'antiprotons distinctes. Le flux d'antideuterons obtenu s'avère plus important que les précédentes estimations. De plus, la prise en compte de processus jusque là ignorés, conduit à un flux non négligeable à basse énergie où le flux d'antideuterons issus de sources exotiques est maximum. La quantité d'antideuterons ainsi produite par la galaxie est suffisante pour espérer détecter prochainement des antideuterons dans le RC. Par contre, la quantité d'antihélium 3 et d'antihélium 4 produite n'est pas significative, c'est pourquoi un antihélium 4 détecté ne sera très probablement pas d'origine secondaire.
7

Piégeage et accumulation de positons issus d'un faisceau pulsé produit par un accélérateur pour l'étude de l'interaction gravitationnelle de l'antimatière

Grandemange, Pierre 12 December 2013 (has links) (PDF)
L'expérience GBAR - Gravitational Behaviour of Antihydrogen at Rest - est conçue pour réaliser un test direct du principe d'équivalence faible sur l'antimatière. Son objectif est de mesurer l'accélération d'un antiatome d'hydrogène en chute libre, appelée Gbar. Son originalité réside dans la production d'antiions Hbar+ pour appliquer le refroidissement sympathique afin d'obtenir une température de l'ordre du µK, indispensable à la réalisation de la mesure. Les ions Hbar+ sont produits par les réactions : pbar + Ps -> Hbar + e-, puis Hbar + Ps -> Hbar+ + e-, où pbar représente l'antiproton, Ps le positronium (l'état lié entre le positon et l'électron), Hbar l'antihydrogène et Hbar+ l'antiion associé. Pour produire la quantité de Ps nécessaire à l'expérience GBAR, 2x10^10 positons doivent être injectés sur une cible mésoporeuse de SiO2 en moins de 100ns. Un tel flux nécessite l'accumulation et le refroidissement des positons dans un piège à particules.Cette thèse décrit l'injecteur de positons en phase de démonstration à Saclay pour l'expérience GBAR. Il est constitué d'un piège de Penning-Malmberg (emprunté au laboratoire du RIKEN) alimenté par un faisceau de positons lents. Un accélérateur linéaire d'électrons de 4.3MeV produit le faisceau pulsé de positons en tirant sur une cible de tungstène, modéré ensuite par un modérateur constitué de multiples couches de grilles de tungstène. Le flux de positons lents est de 10^4 e+/pulse, soit 2x10^6 e+/s à 200Hz. Nous présentons dans ce document la toute première accumulation de positons produit par un accélérateur (plutôt qu'une source radioactive), et leur refroidissement dans un plasma de 2x10^10 électrons préalablement chargés dans le piège.
8

Charmless hadronic three-body decays of neutral B mesons with a Kos in the final state in the LHCb experiment : branching fractions and an amplitude analysis / Désintégrations hadroniques à trois corps sans charme de mésons beaux avec un Kos dans l'état final dans l'expérience LHCb : mesure de rapports d'embranchement et une analyse en amplitude

Henry, Louis 30 September 2016 (has links)
Dans cette thèse sont présentées plusieurs études relatives aux désintégrations de mésons Bd et Bs en trois corps sans charme avec un KS dans l'état final.Ces analyses portent sur des données collectées par l'expérience LHCb durant le Run I du LHC, et qui correspondent à une luminosité intégrée de 3 fb-1.Une première analyse consiste à la mesure des rapports d'embranchements des modes B(d,s) -> KSh+h'-, ou h(') désigne un kaon ou un pion.Les mesures précédemment effectuées par LHCb de ces rapports d'embranchement, relativement à celui du mode Bd->KSpi+pi-, sont actualisées.Le but principal de cette analyse est la recherche du mode Bs -> KSK+K-, qui n'a jamais encore été observé.Les rapports d'embranchements, relativement à celui de Bd -> KSpi+pi-, sont mesurés : B(Bs->KSpi+pi-)/B(Bd->KSpi+pi-) = 0.26 +/- 0.04(stat.) +/- 0.02(syst.) +/- 0.01(f_s/f_d) B(Bd->KSKpi)/B(Bd->KSpi+pi-) = 0.17 +/- 0.02(stat.) +/- 0.00(syst.) B(Bs->KSKpi)/B(Bd->KSpi+pi-) = 1.84 +/- 0.07(stat.) +/- 0.02(syst.) +/- 0.04(f_s/f_d) B(Bd->KSKK)/B(Bd->KSpi+pi-) = 0.59 +/- 0.02(stat.) +/- 0.01(syst.)Une première observation de Bs->KSK+K-, correspondant à une significance globale de 3.7 sigmas, est effectuée.Une analyse du plan de Dalitz indépendante du temps et sans étiquetage de saveur du canal Bd -> KSK+K- est effectuée en utilisant l'approche isobare.Les rapports d'embranchement des désintégration quasi-deux-corps des canaux Bd->KS phi, Bd->KS f'2(1525) et Bd->KS chic0 sont mesurés.Ils sont compatibles avec des mesures précédentes effectuées par Babar. / This dissertation presents several studies of the decays of both Bd and Bs mesons to charmless three-body final states including a KS meson.They use the data recorded by the LHCb experiment during Run I of LHC, corresponding to an integrated luminosity of 3 fb-1.A first analysis consists of the measurement of the branching fractions of B(d,s)->KSh+h'- decays, where h(') designates a kaon or a pion.Preceding LHCb measurements of branching fractions for all decay channels, relative to that of Bd->KSpi+pi-, are updated.Furthermore, the primary goal of this analysis is to search for the, as yet, unobserved decay Bs->KSK+K-.The relative branching fractions are measured to be: B(Bs->KSpi+pi-)/B(Bd->KSpi+pi-) = 0.26 +/- 0.04(stat.) +/- 0.02(syst.) +/- 0.01(f_s/f_d) B(Bd->KSKpi)/B(Bd->KSpi+pi-) = 0.17 +/- 0.02(stat.) +/- 0.00(syst.) B(Bs->KSKpi)/B(Bd->KSpi+pi-) = 1.84 +/- 0.07(stat.) +/- 0.02(syst.) +/- 0.04(f_s/f_d) B(Bd->KSKK)/B(Bd->KSpi+pi-) = 0.59 +/- 0.02(stat.) +/- 0.01(syst.) A first observation of Bs->KSK+K- is reported with a global significance of 3.7 sigmas.A flavour-untagged, time-independent Dalitz-plot analysis of Bd->KSK+K- is presented, using the isobar approach.The quasi-two-body branching fractions of Bd->KS phi, Bd->KS f'2(1525), and Bd->KS chic0 are measured.They are compatible with previous measurements from Babar.
9

Laser cooling and manipulation of antimatter in the AEgIS experiment / Manipulation et refroidissement laser de l'antimatière, au sein de l'expérience AEgIS

Yzombard, Pauline 24 November 2016 (has links)
Ma thèse s’est déroulée dans le cadre de la collaboration AEgIS, une des expériences étudiant l’antimatière au CERN. L’objectif final est de mesurer l’effet de la gravité sur un faisceau froid d’antihydrogène (Hbar). AEgIS se propose de créer les Hbar froids par échange de charges entre un atome de Positronium (Ps) excité (état de Rydberg) et un antiproton piégé : 〖Ps〗^*+ pbar → (H^*)⁻ + e⁻. L’étude de la physique du Ps est cruciale pour AEgIS, et demande des systèmes lasers adaptés. Pendant ma thèse, ma première tâche a été de veiller au bon fonctionnement des systèmes lasers de l’expérience. Afin d’exciter le positronium jusqu’à ses états de Rydberg (≃20) en présence d’un fort champ magnétique (1 T), deux lasers pulsés spectralement larges ont été spécialement conçu. Nous avons réalisé la première excitation par laser du Ps dans son niveau n=3, et prouvé une excitation efficace du nuage de Ps vers les niveaux de Rydberg n=16-17. Ces mesures, réalisées dans la chambre à vide de test d’AEgIS, à température ambiance et pour un faible champ magnétique environnant, sont la première étape vers la formation d’antihydrogène. Le prochain objectif est de répéter ces résultats dans l’enceinte du piège à 1 T, où les antihydrogènes seront formés. Pour autant, malgré l’excitation Rydberg des Ps pour accroître la section efficace de collision, la production d’antihydrogène restera faible, et la température des H bar formés sera trop élevée pour toute mesure de gravité. Pendant ma thèse, j’ai installé au CERN un autre système laser prévu pour pratiquer une spectroscopie précise des niveaux de Rydberg du Ps. Ce système excite des transitions optiques qui pourraient convenir à un refroidissement Doppler : la transition n=1 ↔ n=2. J’ai étudié la possibilité d’un tel refroidissement, en procédant à des simulations poussées pour déterminer les caractéristiques d’un système laser adapté La focalisation du nuage de Ps grâce au refroidissement des vitesses transverses devrait accroitre le recouvrement des positroniums avec les antiprotons piégés, et ainsi augmenter grandement la production d’Hbar. Le contrôle du refroidissement et de la compression du plasma d’antiprotons est aussi essentiel pour la formation des antihydrogènes. Pendant les temps de faisceaux d’antiprotons de 2014 et 2015, j’ai contribué à la caractérisation et l’optimisation des procédures pour attraper et manipuler les antiprotons, afin d’atteindre des plasmas très denses, et ce, de façon reproductible. Enfin, j’ai participé activement à l’élaboration d’autre projet à l’étude AEgIS, qui vise aussi à augmenter la production d’antihydrogène : le projet d’un refroidissement sympathique des antiprotons, en utilisant un plasma d’anions refroidis par laser. J’ai étudié la possibilité de refroidir l’ion moléculaire C₂⁻, et les résultats de simulations sont encourageants. Nous sommes actuellement en train de développer au CERN le système expérimental qui nous permettra de faire les premiers tests de refroidissement sur le C₂⁻. Si couronné de succès, ce projet ne sera pas seulement le premier résultat de refroidissement par laser d’anions, mais ouvrira aussi les portes à une production efficace d’antihydrogènes froids. / My Ph.D project took place within the AEgIS collaboration, one of the antimatter experiments at the CERN. The final goal of the experiment is to perform a gravity test on a cold antihydrogen (Hbar) beam. AEgIS proposes to create such a cold Hbar beam based on a charge exchange reaction between excited Rydberg Positronium (Ps) and cold trapped antiprotons: 〖Ps〗^* + pbar → (H^*)⁻ + e⁻. Studying the Ps physics is crucial for the experiment, and requires adapted lasers systems. During this Ph.D, my primary undertaking was the responsibility for the laser systems in AEgIS. To excite Ps atom up to its Rydberg states (≃20) in presence of a high magnetic field (1 T), two broadband pulsed lasers have been developed. We realized the first laser excitation of the Ps into the n=3 level, and demonstrated an efficient optical path to reach the Rydberg state n=16-17. These results, obtained in the vacuum test chamber and in absence of strong magnetic field, reach a milestone toward the formation of antihydrogen in AEgIS, and the immediate next step for us is to excite Ps atoms inside our 1 T trapping apparatus, where the formation of antihydrogen will take place. However, even once this next step will be successful, the production rate of antihydrogen atoms will nevertheless be very low, and their temperature much higher than could be wished. During my Ph.D, I have installed further excitation lasers, foreseen to perform fine spectroscopy on Ps atoms and that excite optical transitions suitable for a possible Doppler cooling. I have carried out theoretical studies and simulations to determine the proper characteristics required for a cooling laser system. The transverse laser cooling of the Ps beam will enhance the overlap between the trapped antiprotons plasma and the Ps beam during the charge-exchange process, and therefore drastically improve the production rate of antihydrogen. The control of the compression and cooling of the antiproton plasma is also crucial for the antihydrogen formation. During the beam-times of 2014 and 2015, I participated in the characterization and optimization our catching and manipulation procedures to reach highly compressed antiproton plasma, in repeatable conditions. Another project in AEgIS I took part aims to improve the formation rate of ultracold antihydrogen, by studying the possibility of a sympathetically cooling of the antiprotons using a laser-cooled anion plasma. I investigated some laser cooling schemes on the C₂⁻ molecular anions, and the simulations are promising. I actively contribute to the commissioning of the test apparatus at CERN to carry on the trials of laser cooling on the C₂⁻ species. If successful, this result will not only be the first cooling of anions by laser, but will open the way to a highly efficient production of ultracold antihydrogen atoms.
10

Study of the antihydrogen atom and ion production via charge exchange reaction on positronium / Étude de la production d'atomes et d'ions d'antihydrogène par réaction d'échange de charge avec du positronium

Latacz, Barbara Maria 24 September 2019 (has links)
Le but principal de la collaboration GBAR est de mesurer le comportement d'atomes d'antihydrogène sous l'effet de la gravité terrestre. Ceci est fait en mesurant la chute libre classique d'atomes d'antihydrogène, qui est un test direct du principe d'équivalence faible pour l'antimatière. La première étape de l'expérience est de produire des ions d'antihydrogène et de les amener dans un piège de Paul, où ils peuvent être refroidis à une température de l'ordre du μK en utilisant la technique du refroidissement sympathique avec des ions Be⁺ eux-mêmes mis dans leur état fondamental par la technique Raman à bande latérale. Une température de l'ordre du μK correspond à une vitesse de la particule de l'ordre de 1 m/s. Une fois cette vitesse atteinte, l'ion antihydrogène peut être neutralisé et commence sa chute. Ceci permet une précision de 1 % sur la mesure de l’accélération gravitationnelle g pour l’antimatière avec environ 1500 événements. Cependant, pour mesurer la chute libre, il faut d'abord produire l'ion antihydrogène. Celui-ci est formé dans les réactions d'échange de charge entre des antiprotons et des antihydrogènes avec du positronium. Positronium et atomes d'antihydrogène peut se trouver soit à l’état fondamental, soit dans un état excité. Une étude expérimentale de la mesure de la section efficace de ces deux réactions est décrite dans cette thèse. La production de l'atome d'antihydrogène ainsi que de l'ion se passe à l’intérieur d'une cavité. La formation d'un antihydrogène ion lors d'une interaction entre faisceaux requiert environ 5x10⁶ antiprotons/paquet et quelques 10¹¹ Ps/cm⁻³ de densité de positronium à l’intérieur d'une cavité. Celle-ci est produite par un faisceau contenant 5x10¹⁰ positrons par paquet. La production de faisceaux aussi intenses avec les propriétés requises est en soi un challenge. Le développement de la source de positrons de GBAR est décrite. Celle-ci est basée sur un accélérateur linéaire à électrons de 9 MeV. Le faisceau d’électrons est incident sur une cible de tungstène où les positrons sont créés par rayonnement de freinage (gammas) et création de paires. Une partie des positrons ainsi créés diffusent à nouveau dans un modérateur de tungstène en réduisant leur énergie à environ 3 eV. Ces particules sont re-accélérées à une énergie d'environ 53 eV. Aujourd'hui, le flux mesuré de positrons est au niveau de 6x10⁷ e⁺/s, soit quelques fois. Puis la thèse comporte une courte description des préparatifs pour les faisceaux d'antiprotons ou de protons, terminée par un chapitre sur le taux de production attendu d'atomes et d'ions d'antihydrogène. En aval de la réaction, les faisceaux d'antiprotons, d'atomes et d'ions d'antihydrogène sont guidés vers leur système de détection. Ceux-ci ont été conçus de façon à permettre la détection d'un à plusieurs milliers d'atomes d'antihydrogène, un seul ion antihydrogène et tous les 5x10⁶ antiprotons. Ceci est particulièrement difficile parce que l'annihilation des antiprotons crée beaucoup de particules secondaires qui peuvent perturber la mesure d'un atome ou ion. La majeure partie de la thèse consiste en la description des bruits de fond attendus pour la détection des atomes et ions d'antihydrogène. De plus, le système de détection permet de mesurer les sections efficaces pour les réactions symétriques de production d'atomes et d'ions hydrogèene par échange de charge entre protons et positronium. La partie production d’antihydrogène ions de l’expérience a été complètement installée au CERN en 2018. Les premiers tests avec des antiprotons provenant du décélérateur ELENA ont été effectués. Actuellement, l’expérience est testée avec des positrons et des protons, de façon à former des atomes et ions hydrogène. Une optimisation de la production de ces ions de matière aidera à se préparer pour la prochaine période de faisceau d'antiprotons en 2021. / The main goal of the GBAR collaboration is to measure the Gravitational Behaviour of Antihydrogen at Rest. It is done by measuring the classical free fall of neutral antihydrogen, which is a direct test of the weak equivalence principle for antimatter. The first step of the experiment is to produce the antihydrogen ion and catch it in a Paul trap, where it can be cooled to μK temperature using ground state Raman sideband sympathetic cooling. The μK temperature corresponds to particle velocity in the order of 1 m/s. Once such velocity is reached, the antihydrogen ion can be neutralised and starts to fall. This allows reaching 1 % precision on the measurement of the gravitational acceleration g for antimatter with about 1500 events. Later, it would be possible to reach 10⁻⁵ - 10⁻⁶ precision by measuring the gravitational quantum states of cold antihydrogen. However, in order to measure the free fall, firstly the antihydrogen ion has to be produced. It is formed in the charge exchange reactions between antiproton/antihydrogen and positronium. Positronium and antihydrogen atoms can be either in a ground state or in an excited state. An experimental study of the cross section measurement for these two reactions is described in the presented thesis. The antihydrogen atom and ion production takes place in a cavity. The formation of one antihydrogen ion in one beam crossing requires about 5x10⁶ antiprotons/bunch and a few 10¹¹ Ps/cm⁻³ positronium density inside the cavity, which is produced with a beam containing 5x10¹⁰ positrons per bunch. The production of such intense beams with required properties is a challenging task. First, the development of the positron source is described. The GBAR positron source is based on a 9 MeV linear electron accelerator. The relatively low energy was chosen to avoid activation of the environment. The electron beam is incident on a tungsten target where positrons are created from Bremsstrahlung radiation (gammas) through the pair creation process. Some of the created positrons undergo a further diffusion in the tungsten moderator reducing their energy to about 3 eV. The particles are re-accelerated to about 53 eV energy and are adiabatically transported to the next stage of the experiment. Presently, the measured positron flux is at the level of 6x10⁷ e⁺/s, which is a few times higher than intensities reached with radioactive sources. Then, the thesis features a short description of the antiproton/proton beam preparations, finalised with a chapter about the expected antihydrogen atom and ion production yield. After the reaction, antiproton, antihydrogen atom, and ion beams are guided to the detection system. It is made to allow for detection from 1 to a few thousand antihydrogen atoms, a single antihydrogen ion and all 5x10⁶ antiprotons. It is especially challenging because antiproton annihilation creates a lot of secondary particles which may disturb measurements of single antihydrogen atoms and ions. The main part of the Thesis is the description of the expected background for the antihydrogen atom and ion detection. Additionally, the detection system allows measuring the cross sections for the symmetric reactions of a hydrogen atom and ion production through charge exchange between protons and positronium. The antihydrogen ion production part of the experiment was fully installed at CERN in 2018. The first tests with antiprotons from the ELENA decelerator were done. Currently, the experiment is being commissioned with positrons and protons, in order to perform the hydrogen atom and ion formation. The optimisation of the ion production with matter will help to be fully prepared for the next antiproton beam time in 2021.