• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 35
  • 5
  • Tagged with
  • 41
  • 23
  • 17
  • 17
  • 14
  • 12
  • 10
  • 10
  • 10
  • 9
  • 9
  • 8
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Resistência e ductilidade das ligações laje-pilar em lajes-cogumelo de concreto de alta resistência armado com fibras de aço e armadura transversal de pinos / Resistance and ductiliy of slab-column connections on high strength concrete flat slabs with steel fibers and shear reinforcement

Aline Passos de Azevedo 22 April 1999 (has links)
Neste trabalho analisa-se a resistência à punção e a ductilidade das ligações laje-pilar em doze modelos de lajes-cogumelo de concreto armado, nas quais se efetuam combinações de emprego de concreto de alta resistência, diferentes volumes de fibras de aço e uso de armadura transversal na forma de conectores de aço tipo pino. Todas as lajes são quadradas com 1160 mm de lado e 100 mm de espessura. A armadura de flexão foi composta de barras de aço de 10 mm espaçadas de tal forma a resistir a um momento fletor único em ambas direções. Os conectores, quando utilizados, foram dispostos radialmente e compostos de barras de aço de 6.6 mm soldadas a segmentos de ferro chato nas duas extremidades. Para avaliar a capacidade resistente dos modelos de ligação laje-pilar e observar o ganho de ductilidade que as fibras proporcionam, foram ensaiados segmentos-de-laje, os quais representam uma faixa destes modelos de ligação laje-pilar. Foi utilizado um sistema de ensaio dotado de atuador hidráulico servo-controlado, programado para ensaio com deformação controlada e aquisição contínua dos dados, o que permitiu a avaliação do comportamento pós-pico de resistência e a realização de medições de resistência residual. Várias hipóteses de cálculo foram utilizadas para avaliar a resistência última das ligações laje-pilar. Empregou-se um critério de classificação para caracterizar o tipo de ruptura em: punção ou flexão predominante ou uma combinação de punção-flexão. Constatou-se que o emprego de concreto de alta resistência, juntamente com armadura transversal, aumenta substancialmente a resistência da ligação laje-pilar, e quando combinado com fibras de aço, consegue-se um considerável aumento da ductilidade. / This work analyses the punching shear resistance and ductility of slab-column connections on twelve concrete flat slab models. The model characteristics resulted from combinations of the application of high or ordinary strength concrete, different steel fiber volume fractions and use or not of shear reinforcement. All the slabs are square with 1,160 mm of side and 100 mm of thickness. The main flexural reinforcement was composed of 10 mm steel bars spaced in such a way to resist to the same bending moment in both directions. When used, the shear reinforcement of steel studs were disposed in radial directions and consisted of 6.6 mm steel bars welded to flat steel segments in their ends. To evaluate the resistant capacity of slab-column connection models and to observe the ductility that the fibers provide, they were rehearsed segments-of-slab, which represents a strip of these slab-column connection models. A testing system with a servo-controlled hydraulic jack was used and it was programmed for a controlled deformation test and continuous data acquisition. This method allowed the evaluation of the post-peak strength behavior and the measurement of residual resistance forces. Several calculations hypotheses were used to evaluate the ultimate strength of the slab-column connections. A classification criterium was applied to characterize the failure type as: predominant punching or flexure or a combination of punching-flexure. It was verified that the application of high strength concrete, together with shear reinforcement, increases substantially the slab-column connection strength, and, when combined with steel fibers, a considerable ductility increase is achieved.
32

Influência do confinamento na resistência e ductilidade de pilares curtos de concreto de ultra alta resistência submetidos à compressão centrada / Influence of confinement on strength and ductility of short ultra high strength concrete columns subjected to compressive force

Lincoln Grass Viapiana 17 March 2016 (has links)
Neste estudo foram analisados experimentalmente o comportamento de 24 pilares curtos de Concreto de Ultra Alta Resistência - CUAR, confinados por armaduras helicoidais, avaliando especificamente os acréscimos de resistência e ductilidade obtidos com diferentes níveis de pressão lateral de confinamento. Na etapa experimental foram realizados ensaios de pilares curtos de CUAR com as seguintes características: - seção circular de 7,2 cm de diâmetro e comprimento de 23 cm, e quatro níveis de resistência à compressão do concreto sendo eles, 165, 175, 200 e 229 MPa, dosados sem e com adição de fibras metálicas; - diferentes espaçamentos das armaduras helicoidais, de modo que fossem obtidas situações com baixo, médio e alto índice de confinamento e taxa de armadura longitudinal fixa. Os ensaios de compressão centrada foram realizados com controle de deslocamento, de modo que foram obtidas as curvas força x deslocamento completas. Constatou-se que a seção resistente dos pilares de CUAR é a formada pelo núcleo de concreto confinado, área delimitada pelo eixo da armadura transversal. Observou-se que o CUAR com fibras metálicas apresenta maior deformação do núcleo de concreto confinado em relação ao núcleo de concreto confinado de CUAR sem adição de fibras metálicas, indicando dessa forma, que os pilares de CUAR com fibras metálicas apresentam comportamento mais dúctil. Para as situações de alto confinamento foram gerados ao concreto do núcleo confinado significativos acréscimos de resistência e deformação axial, aumentando a resistência do concreto confinado em relação a resistência do concreto não confinado em: 82,26%, 75,34%, 90,46% e 70,51%, respectivamente, e as deformações axiais do concreto confinado em relação a deformação axial do concreto não confinado em: 433%, 474%, 647% e 550%. Finalmente, acredita-se que os resultados obtidos poderão trazer subsídios para aplicações futuras desta técnica de confinamento na construção de novos elementos estruturais e no reforço de pilares submetidos a elevados níveis de solicitação axial. / This study evaluated experimentally the behavior of 24 short columns of Ultra High Strength Concrete - UHSC confined by helical transverse reinforcement, specifically evaluating strength increases and ductility obtained with different levels of lateral pressure of confinement. In the experimental phase short UHSC columns with the following characteristics were tested: - circular cross section of 7.2 cm diameter and 23 cm length, four levels of concrete strength (165, 175, 200 and 229 MPa), with and without addition of metallic fibers; - different spacing of transverse reinforcement, so that situations were obtained with low, medium and high level of confinement, while the longitudinal reinforcement ratio was fixed. The centered compression tests were conducted with displacement control, so that complete force x displacement curves were obtained. It was found that the resistant section of UHSC columns is formed by the confined concrete core delimited by the axis of the transverse reinforcement. It was observed that the axial displacement reached in columns with steel fibers was higher than without fibers, indicating that columns with steel fibers exhibit more ductile behavior. For high confinement levels significant axial strength and displacement increases were observed. Increases of axial strength of confined concrete in comparison to unconfined concrete were 82.26%, 75.34%, 90, 46% and 70.51%. Axial displacements were increased by 433%, 474%, 647% and 550%. Finally, it is believed that the results could provide information for future applications of this technique in construction of a new type of columns or in strengthening of columns subjected to high levels of axial force.
33

Diseño, según estados límites, de estructuras de hormigón armado con redondos de fibra de vidrio GFRP

Almerich Chulia, Ana Isabel 14 February 2011 (has links)
Desde la aparición de los redondos de fibra de vidrio como armado del hormigón, las recomendaciones existentes sobre su uso, están en continua revisión al tratarse de un material innovador en el mundo de la ingeniería. Sin embargo, todos los códigos y guías de diseño existentes de elementos de hormigón armado con redondos de GFRP, no consideran en el diseño la resistencia a compresión de los redondos, al no existir métodos de ensayos contrastados, ni resultados homogéneos en los mismos, despreciándose su contribución debido a su bajo módulo de elasticidad, y a consideraciones económicas injustificables. Esta tesis se centra en definir un método de diseño y cálculo de elementos de hormigón armado con redondos de fibra de vidrio, incluyendo su uso como armadura a compresión, así como su posible resistencia frente al fuego. La tesis presenta una metodología adecuada a una investigación de los elementos de hormigón armado con este tipo de redondos, basándose principalmente en una amplia base experimental. Se realiza una recopilación bibliográfica y una elaboración de un estado del arte de las aplicaciones de los redondos de FRP como armado del hormigón, y de las directrices existentes en cada uno de los códigos o guías vigentes. Tras ello, se recoge el proceso y los resultados de los trabajos experimentales de los ensayos de tracción, compresión, cortante y adherencia ejecutados a las probetas de fibra de vidrio RTHp, con el fin de obtener de sus características mecánicas, para posteriormente lograr su ratificación por el CSIC, a través del Instituto "Eduardo Torroja", dando pie a la comprobación de su uso como armadura a compresión en elementos de hormigón armado. Conocido el comportamiento de los redondos, se elabora unas directrices de diseño para elementos de hormigón armado bajo estados limites, cumpliendo con los preceptos marcados por la EHE-08 con respecto a la compatibilidad de tensiones y deformaciones. / Almerich Chulia, AI. (2011). Diseño, según estados límites, de estructuras de hormigón armado con redondos de fibra de vidrio GFRP [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/9744 / Palancia
34

Comparação experimental entre tipos de armadura de cisalhamento para combate à punção em lajes cogumelo de concreto armado: Stud rails e Double headed studs / Comparison between experimental types of shear reinforcement to combat punch mushroom slabs of concrete, "Stud rails" and "Double headed studs"

RODRIGUES, David Rosa 29 September 2009 (has links)
Made available in DSpace on 2014-07-29T15:03:41Z (GMT). No. of bitstreams: 1 David Rosa Rodrigues.pdf: 6647846 bytes, checksum: 0949b9b9e50ce27a724b92ea2943c5d1 (MD5) Previous issue date: 2009-09-29 / This research presents the results of an experimental comparison between the types of shear reinforcement "stud rails" and "double headed studs" to combat the punching shear of a reinforced concrete flat slabs. It also presents a comparison of experimental results with those provided under the ACI 318/2005, CEB-FIP MC/1990, EUROCODE 2/2004 and NBR 6118:2003. The motivation was to investigate the efficiency of these shear reinforcement for the differences between them. It was tested six slabs of concrete to concentric load, with dimensions of 2400 mm x 2400 mm x 150 mm. It was concreted a column of section 500 mm x 200 mm to 850 mm total height next to the slab. The main variables were the type of shear reinforcement "stud rails" x "double headed studs, the "studs" diameter and the shear reinforcement area per layer. The slabs were tested until the failure. It was monitored the deflection, reinforcement deformation of bending and shear. All slabs failed by punching with internal surface rupture. The experimental results after being compared with the expected standard in each individual calculation showed conservative values. Slabs of Group 1 with "stud rails" presented failed loads greater than those in Group 2 with "double headed studs. Codes/standards 318/2005 ACI, CEB-FIP MC/1990, EUROCODE 2 / 2004 and NBR 6118:2003 safely predict the failed loads of all slabs. The base of the shear reinforcement type "stud rails" moving inside the column may have reduced the failed load of the slab L3. Shear reinforcement type stud rails it is easer of assembly and play than the type double headed studs . / Esta pesquisa apresenta os resultados de uma comparação experimental entre os tipos de armadura de cisalhamento stud rails e double headed studs para combate à punção em lajes cogumelo de concreto armado. Apresenta, também, uma comparação dos resultados experimentais com os previstos segundo o ACI 318/2005, CEB-FIP MC/1990, EUROCODE 2/2004 e a NBR 6118:2003. A motivação foi investigar a eficiência destas armaduras de cisalhamento a procura de diferenças entre elas. Foram ensaiadas seis lajes maciças de concreto armado à punção centrada, com dimensões 2400 mm x 2400 mm x 150 mm. Foi concretado junto à laje um pilar de seção 500 mm x 200 mm com altura total 850 mm. As principais variáveis foram o tipo de armadura de cisalhamento: stud rails x double headed studs , o diâmetro dos studs e a área de armadura de cisalhamento por camada. As lajes foram ensaiadas até a ruptura. Foram monitoradas as flechas, deformações da armadura de flexão e cisalhamento. Todas as lajes romperam por punção com superfície de ruptura interna. Os resultados experimentais após serem comparados com os esperados segundo cada norma de cálculo apresentaram valores conservadores. As lajes do Grupo 1 com stud rails apresentaram cargas de ruptura maiores que as do Grupo 2 com double headed studs . Os códigos/normas ACI 318/2005, CEB-FIP MC/1990, EUROCODE 2/2004 e a NBR 6118:2003 previram com segurança as cargas de ruptura de todas as lajes. A base da armadura de cisalhamento tipo stud rails avançando dentro do pilar pode ter reduzido a carga de ruptura da Laje L3. A armadura de cisalhamento tipo stud rails apresenta maior facilidade de montagem e execução que a tipo double headed studs .
35

Contribuição à análise da resistência à força cortante em lajes de concreto estrutural sem armadura transversal / Contribution to the analysis of shear strength in structural concrete slabs without transverse reinforcement

Sousa, Alex Micael Dantas de 18 March 2019 (has links)
A resistência à força cortante em lajes de pontes sem armadura transversal têm sido um aspecto preocupante nas verificações de estruturas de concreto estrutural construídas décadas passadas e está diretamente relacionado aos modelos de cálculo de resistência à força cortante e de largura colaborante empregados no caso de cargas parcialmente distribuídas próximas do apoio. Entretanto, não existem ainda estudos nacionais relacionados ao nível de acurácia e precisão das abordagens geralmente empregadas na prática de projetos de pontes no Brasil. Por esta razão, propõem-se apresentar uma contribuição às análises de resistência à força cortante em lajes de pontes com ênfase no modelo de cálculo da ABNT NBR 6118:2014. Para isto foram comparados os resultados experimentais e teóricos utilizando diferentes modelos de resistência à força cortante e uma base de dados construída a partir de 642 resultados experimentais. Posteriormente, alguns modelos experimentais foram explorados por meio de simulações numéricas em elementos finitos no intuito de avaliar o nível de aproximações desta abordagem e investigar a influência de parâmetros como mísulas na proximidade dos apoios. Dentre os principais resultados desta pesquisa destaca-se que o valor médio da relação entre a resistência à força cortante teórica e experimental Vexp/Vcal utilizando a ABNT NBR 6118:2014 variou de 2,145 a 1,140 conforme o modelo de largura colaborante utilizado. Enquanto isso, os modelos numéricos calibrados apresentaram relação Vexp/VMEF variando entre 0,95 e 1,01 e com coeficientes de variação menores que 15%. De maneira geral, identificou-se que os modelos de resistência à força cortante apresentam elevados níveis de dispersão entre resultados teóricos e experimentais no caso de lajes e faixas de laje e que os modelos mais usuais de definição da largura colaborante não são precisamente adequados para o caso de cargas parcialmente distribuídas próximas do apoio. / The shear strength in bridge slabs without transverse reinforcement has been a matter of concern in structural concrete structures checks built in the past decades and is directly related to the shear force and effective width calculation models employed in the case of partially distributed loads close to the support. However, there are still no national studies related to the level of accuracy and precision of the approaches commonly used in the practice of bridge projects in Brazil. For this reason, it is proposed to contribute to the shear strength analyzes in bridge slabs with emphasis on the calculation model of ABNT NBR 6118: 2014. For this, we compared the experimental and theoretical results using different models of shear strength and a database constructed from 642 experimental results. Subsequently, some experimental models were explored by means of numerical simulations in finite elements in order to evaluate the level of approximations of this approach and to investigate the influence of parameters such as greater thickness close to the supports. Among the main results of this research, it is worth noting that the average value of the relationship between theoretical and experimental shear strength Vexp/Vcal using ABNT NBR 6118: 2014 varied from 2,145 to 1,140 according to the effective width model used. Meanwhile, the calibrated numerical models showed Vexp/VMEF ratio varying between 0.95 and 1.01 and with coefficients of variation lower than 15%. In general, it was identified that the shear strength models present high levels of dispersion between theoretical and experimental results in the case of slabs and slab strips and that the most usual models of defining the effective width are not precisely adequate for the partially distributed loads close to the support in slabs.
36

Estudo de colunas curtas de concreto confinadas / Study of confined concrete short columns

Rivetti, Marianna Luna Sousa 27 June 2013 (has links)
The confinement of concrete structures has been used for reinforcement and rehabilitation of compressed structural elements, with the objective of increasing their strength capacity and ductility. Various types of reinforcement are used: metal pipes, fiber reinforced polymers, transverse reinforcement, among others. Understanding the stress-strain behavior of confined concrete columns is an important aspect to be considered in the design of these structural elements. This work presents a study of short columns of concrete confined by transverse reinforcement and fiber reinforced polymers subjected to the centered load, employing a nonlinear theoretical model that allows obtaining the stress-strain curves. Concrete columns with various strength levels and different cross-sectional shapes are considered. The employed model is modified according with the type of analyzed problem and a comparative analysis is carried out to verify the performance of the models, considering the experimental results from several examples of short columns confined available in the literature. / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / O confinamento de estruturas de concreto vem sendo utilizado no reforço e reabilitação de peças comprimidas, com o objetivo de aumentar sua capacidade resistente e dutilidade. Vários tipos de reforços são usados: tubos metálicos, polímeros reforçados com fibras, armaduras transversais, entre outros. A compreensão do comportamento tensão-deformação de colunas de concreto confinadas é um aspecto importante a considerar para um projeto confiável desses elementos estruturais. Este trabalho apresenta um estudo de colunas curtas de concreto confinadas por armadura transversal e polímeros reforçados com fibras submetidas à carga centrada, empregando um modelo teórico não linear que permite a obtenção das curvas tensão-deformação. São considerados concretos de variadas resistências e diferentes formas de seção transversal. O modelo empregado é modificado se adequando aos diversos casos analisados, e para verificação do desempenho deste é realizada uma análise comparativa considerando os resultados experimentais provenientes de vários exemplos de colunas curtas confinadas disponíveis na literatura.
37

AVALIAÇÃO DO DESEMPENHO DE CONCRETOS COM ADIÇÕES MINERAIS QUANTO À CORROSÃO DAS ARMADURAS INDUZIDA POR CLORETOS / Performance evaluation of concretes content with mineral additions in relation to the reinforcing steels corrosion induced by chlorides

OLIVEIRA, Andrielli Morais de 29 August 2007 (has links)
Made available in DSpace on 2014-07-29T15:03:38Z (GMT). No. of bitstreams: 1 dissertacao Adrielli.pdf: 5370662 bytes, checksum: 4e167ff0f119f9298b4d7ed2791baa06 (MD5) Previous issue date: 2007-08-29 / The present work aims to study the performance of concrete with regard to the action of chloride ions, evaluating the influence of both mineral additions and water/binder ratio (w/b), considering kinetic and thermodynamic aspects of the corrosive phenomenon. A experimental research was carried out considering the following variables: the presence of mineral additions in partial substitution to the cement weight (10% of silica fume; 25% of fly ash; 10%, 20% and 30% of metakaolin) and the water/binder ratio (0,40 and 0,55). Thus, cubic concrete test specimens were produced, in addition to cylindrical test specimens for concrete characterization in relation to the compressive strength, specific mass, void ratio and capillary water absorption. After 645 days of casting, the cubic concrete test specimens were submitted to the chlorides attack during 308 days, totality 44 weekly cycles of immersion in chlorides aggressive solution. They were monitored, throughout this period, by means of techniques, such as: the concrete electric resistivity, the half-cell potential, the polarization resistance and the electrochemical impedance spectroscopy. At the end of the experiment, visual inspections of reinforcing steels allowed to observe their superficial aspects after attack. As general result, it was gotten that the incorporation of mineral additions to the concretes promoted significant profits in all the evaluated properties, evidencing the beneficial effect of these additions in concretes exposed to aggressive conditions, specially in those in which there are chloride ions. In this direction, the statistical analysis has shown evidences that concretes with silica fume and metakaolin achieved the best results of electrical resistivity. In relation to the half-cell potentials, the reference concrete (without mineral additions) presented the worst performance, with an indication of despassivation in the reinforcing steels accentuated fall in the values of resistance of polarization with the time, proving the susceptibility of these systems to the action of chlorides. The concrete with mineral additions did not present depassivation of the reinforcing steels meaning that these systems possess great durability and service life in relation to those without mineral additions / O presente trabalho tem como objetivo estudar o desempenho de concretos quanto à ação de íons cloreto, avaliando tanto a interveniência das adições minerais incorporadas ao concreto quanto da relação água/aglomerante (a/ag), considerando aspectos cinéticos e termodinâmicos do fenômeno corrosivo. Para tanto, desenvolveu-se uma pesquisa experimental que contemplou as seguintes variáveis: a presença de adições minerais em substituição parcial à massa de cimento (10% de sílica ativa; 25% de cinza volante; 10%, 20% e 30% de metacaulim) e a relação água/aglomerante (0,40 e 0,55). Foram moldados corpos-de-prova cúbicos, além de corpos-de-prova cilíndricos para caracterização dos concretos quanto à resistência à compressão, massa específica, índice de vazios e absorção de água por capilaridade. Após 645 dias de moldagem, os corpos-de-prova cúbicos de concreto foram submetidos ao ataque por cloretos durante 308 dias, totalizando 44 ciclos semanais de imersão em solução agressiva e posterior secagem em ambiente de laboratório. Foram monitorados, ao longo deste período, a resistividade elétrica desses concretos, os potenciais de corrosão, a resistência de polarização e a impedância eletroquímica. Ao fim do experimento, inspeções visuais à armadura permitiram observar o seu aspecto superficial após o período de ataque. Como resultado geral, obteve-se que a incorporação de adições minerais aos concretos promoveu ganhos significativos em todas as propriedades avaliadas, evidenciando o efeito benéfico dessas adições em concretos submetidos às condições agressivas, sobretudo contendo íons cloreto. Nesse sentido, a análise estatística evidenciou que os concretos com sílica ativa e com metacaulim obtiveram os melhores resultados de resistividade elétrica. Quanto aos potenciais de corrosão, os concretos de referência (sem adições minerais) apresentaram desempenho inferior, com a indicação da despassivação das armaduras e a queda acentuada nos valores de resistência de polarização com o tempo, comprovando a susceptibilidade desses sistemas à ação de cloretos. Os concretos com adições minerais não apresentaram despassivação das armaduras, denotando que esses sistemas possuem maior durabilidade e vida útil em comparação àqueles referentes aos concretos sem adição mineral, tendo em vista o ataque por cloretos
38

Avaliação da capacidade de proteção contra a corrosão da arma-dura induzida por cloretos de concretos com adições minerais e inibidores de corrosão / Evaluation of the ability to protect against corrosion of the gun hard-induced chloride concrete with mineral additions and corrosion inhibitors

LIMA, Marcelo Batista 28 September 2009 (has links)
Made available in DSpace on 2014-07-29T15:18:24Z (GMT). No. of bitstreams: 1 pretextual.pdf: 140883 bytes, checksum: 5d9ee4b9b3884a0032825e604304580f (MD5) Previous issue date: 2009-09-28 / Increasing the durability of concrete structural elements is primordial, especially those related to power generation in eolic areas that are subjected to the phenomenon of reinforcement corrosion. In this context, this study aims to evaluate the overall protection ability of concrete to the phenomenon of reinforcement corrosion induced by chlorides. To this end, it was adopted a statistical program based on a fractional factorial design in which the variables studied were as follows: the water-binder ratio (0.35, 0.45 and 0.55), the type of mineral admixture (silica fume and blast furnace slag at specific levels), the type of corrosion inhibitor (calcium nitrite, sodium nitrite and amine) and the level of corrosion inhibitor (minimum and maximum recommended by each manufacturer). In the concrete investigations, the tests performed were corrosion potential, polarization resistance and electrochemical impedance. Throughout the experiments, it was possible to testify the beneficial effect of reducing the water-binder ratio. It was also possible to prove the very positive effect of the incorporation of mineral admixtures, especially of silica fume. The satisfactory performance of various inhibitors evaluated was also verified, specially when concrete contains mineral admixtures. A parallel study was conducted to make a comparative analysis of inhibitors at the same range of concentrations (at solid levels of 0.76%, 2.21% and 3.66% of the compound on the cement mass), nevertheless this study have demonstrated that fixing contents for all inhibitor is not appropriated, and the recommended dosages by the manufacturer is the best condition. As the levels recommended by manufacturers, it was found that the higher percentages have not worked well for sodium nitrite otherwise, for amine and nitrite calcium, the higher levels implied better results. Regarding the tannin inhibitor also assessed in the parallel study mentioned above (related to specific inhibitors), its good performance related to corrosion inhibition happened just for the content of 0.76% (the lowest levels). For the other contents, it was verified anomalous results. These results demonstrated that each type of corrosion inhibitor has its optimal concentration for use in concrete. Based on a cost-benefit analysis and evaluating the increase in the concrete value for cubic meter (in R$) in the presence of inhibitors at the same contents, it was verified a relative parity prices among the tested nitrites and an extremely high cost of amine. However, when performing the same analysis but using the levels recommended by the manufacturers for each inhibitor independent, it was found that the large disparity in prices between nitrite and amine was reduced considerably. An assessment of technical and economic feasibility was also performed based on the efficiency of corrosion inhibition and cost per cubic meter of concrete mixtures that did not show a typical depassivation of their stell bar up to the attack age evaluated / O aumento da durabilidade é um aspecto primordial para os elementos estruturais de concreto, em especial aqueles constituintes das estruturas de geração de energia em parques eólicos, sujeitos ao fenômeno de corrosão das armaduras. Nesse contexto, este trabalho tem como objetivo geral avaliar a capacidade de proteção de diferentes concretoS frente ao fenômeno da corrosão da armadura induzida por cloretos. Para tanto, foi adotado um planejamento estatístico baseado em um modelo fatorial fracionado em que as variáveis estudadas foram: a relação água/aglomerante (0,35; 0,45 e 0,55), o tipo de adição mineral (sílica ativa e escória de alto-forno, em teores específicos), o tipo de inibidor de corrosão (nitrito de cálcio, nitrito de sódio e amina) e o teor de inibidor de corrosão (mínimo e máximo recomendado por cada fabricante). Na avaliação dos concretos, foram realizados ensaios de potencial de corrosão, resistência de polarização e impedância eletroquímica. Ao longo de todo experimento foi possível constatar o efeito benéfico da redução da relação a/agl. Também foi possível verificar o efeito extremamente positivo da incorporação das adições minerais, em especial da sílica ativa. Constatou-se também o efeito positivo dos diversos inibidores avaliados, em seus teores mínimo e máximo, beneficio que se mostrou mais pronunciado quando da utilização conjunta com as adições minerais. Um estudo paralelo foi realizado para se fazer uma análise comparativa dos inibidores dentro da mesma faixa de teores empregados (teores de 0,76%; 2,21% e 3,66% de sólidos do aditivo em relação à massa de cimento), no qual se verificou que a utilização desses teores fixos para os diferentes tipos de inibidores não se mostrou tão eficiente quanto em relação à utilização dos aditivos na dosagem de recomendação do fabricante. Quanto a estes teores (recomendados pelos fabricantes), verificou-se que os percentuais mais altos não funcionaram bem para o nitrito de sódio, ao passo que para a amina e para o nitrito de cálcio os teores mais elevados resultaram em melhores resultados. Em relação ao tanino, inibidor que também foi avaliado no estudo paralelo referido anteriormente (específico sobre os inibidores), só houve algum resultado de inibição de corrosão para o teor de 0,76% (mais baixo dos teores), tendo-se obtido resultados anômalos para os outros 2 teores mais altos. Tais resultados permitiram constatar que cada tipo de inibidor de corrosão possui sua concentração ótima de utilização no concreto. Fazendo-se uma análise de custo e avaliando-se o acréscimo em Reais no valor do m3 do concreto proporcionado pelos diversos aditivos inibidores e nos teores de mesma faixa de emprego, verificou-se uma relativa paridade de preços entre os nitritos e um elevadíssimo custo da amina. No entanto, ao se realizar a mesma análise, mas utilizando os teores recomendados pelos fabricantes de cada inibidor, verificou-se que a grande disparidade de preços entre os nitritos e a amina foi reduzida de forma considerável. Uma avaliação da viabilidade técnico-econômica dos concretos também foi realizada, a partir dos dados de eficiência de inibição à corrosão e custo/m3 das misturas que não apresentaram comportamento típico de despassivação de suas armaduras até a idade de ataque considerada
39

Estudo da aderência de arames da armadura de tração em conectores de dutos flexíveis / Study of adhesion of tensile armor wiles in connectors for flexible pipelines

Marcelo Badini Daflon 08 September 2010 (has links)
Este projeto tem o objetivo de apresentar o estudo dos arames da armadura de tração que são empregados no transporte de óleo, gás e umbilicais hidráulicos na indústria petrolífera. Este estudo foi desenvolvido sob a necessidade de melhor ancoragem dos arames da armadura de tração de modo a garantir que, mesmo após a ruptura do arame dentro do conector não haverá o escorregamento do mesmo provocando a queda do duto flexível. Assim sendo, foi estabelecido o estudo de aderência da interface dos arames da armadura de tração dos dutos flexíveis. Com os ensaios concluídos se estudou um novo procedimento para o melhoramento de aderência mecânica dos arames com a resina epóxi. Após os ensaios de aderência e adesão concluídos foi realizado ensaio de tração em cada arame da armadura de tração sob sua montagem no conector de extremidade para verificação de carregamento que chegam nos ganchos dos arames da armadura de tração. Os estudos realizados no conector de extremidade de 2,5 demonstram que os ganchos dos arames da armadura de tração são de grande importância para a integridade estrutural do duto flexível, visto que o cone de resina formado dentro do conector não está em contato com toda a área dos arames das armaduras de tração. / This project aims to present the study of tensile armor wires usually employed in the transport of oil, gas and hydraulic umbilicals in the petroleum industry. This study was developed as a need for better anchoring of the tensile armor wires in order to guarantee that even after the rupture of the wire within the connector it will not slip causing the fall of the flexible riser. Thus was established the adhesion study of the interface of the tensile armor wires of the flexible risers. After the end of the tests a new procedure for improving mechanical adhesion between the wires and the epoxy resin was studied. After the end of the adhesion tests tensile test was performed on each wire of the tensile armor under its mounting on the end fitting for checking the loading that reaches the hook of the armor wires. The trials performed in the 2.5end fitting show that the tensile armor wire hooks are of great importance for the structural integrity of the flexible riser, as there is no contact between the resin cone formed within the end fitting and the tensile armor wires area.
40

Estudo da aderência de arames da armadura de tração em conectores de dutos flexíveis / Study of adhesion of tensile armor wiles in connectors for flexible pipelines

Marcelo Badini Daflon 08 September 2010 (has links)
Este projeto tem o objetivo de apresentar o estudo dos arames da armadura de tração que são empregados no transporte de óleo, gás e umbilicais hidráulicos na indústria petrolífera. Este estudo foi desenvolvido sob a necessidade de melhor ancoragem dos arames da armadura de tração de modo a garantir que, mesmo após a ruptura do arame dentro do conector não haverá o escorregamento do mesmo provocando a queda do duto flexível. Assim sendo, foi estabelecido o estudo de aderência da interface dos arames da armadura de tração dos dutos flexíveis. Com os ensaios concluídos se estudou um novo procedimento para o melhoramento de aderência mecânica dos arames com a resina epóxi. Após os ensaios de aderência e adesão concluídos foi realizado ensaio de tração em cada arame da armadura de tração sob sua montagem no conector de extremidade para verificação de carregamento que chegam nos ganchos dos arames da armadura de tração. Os estudos realizados no conector de extremidade de 2,5 demonstram que os ganchos dos arames da armadura de tração são de grande importância para a integridade estrutural do duto flexível, visto que o cone de resina formado dentro do conector não está em contato com toda a área dos arames das armaduras de tração. / This project aims to present the study of tensile armor wires usually employed in the transport of oil, gas and hydraulic umbilicals in the petroleum industry. This study was developed as a need for better anchoring of the tensile armor wires in order to guarantee that even after the rupture of the wire within the connector it will not slip causing the fall of the flexible riser. Thus was established the adhesion study of the interface of the tensile armor wires of the flexible risers. After the end of the tests a new procedure for improving mechanical adhesion between the wires and the epoxy resin was studied. After the end of the adhesion tests tensile test was performed on each wire of the tensile armor under its mounting on the end fitting for checking the loading that reaches the hook of the armor wires. The trials performed in the 2.5end fitting show that the tensile armor wire hooks are of great importance for the structural integrity of the flexible riser, as there is no contact between the resin cone formed within the end fitting and the tensile armor wires area.

Page generated in 0.0406 seconds