• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 15
  • 15
  • 11
  • 8
  • 8
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

L’efficacité du pancréas artificiel externe durant l’exercice chez les adultes atteints de diabète de type 1

Taleb, Nadine 08 1900 (has links)
Problématique : l’activité physique est évitée par les patients atteints de diabète de type 1 (DbT1) malgré ses bénéfices et ce par crainte du risque d’hypoglycémie majoré par l’exercice. Le pancréas artificiel externe est une nouvelle technologie de trois composantes qui fonctionnent en boucle fermée, un système de surveillance continue du glucose (SSCG), un algorithme et une pompe à insuline. Peu d’études ont été conçues spécifiquement pour tester le pancréas artificiel pendant l’exercice. De plus, la précision des SSCG pourrait être compromise par les changements rapides du glucose au cours de l’exercice. Objectifs : 1) Tester et comparer l’efficacité des deux versions du pancréas artificiel, simple-hormone (insuline seule) et double-hormone (insuline et glucagon), pour prévenir l’hypoglycémie durant deux types d’exercice, en continu et par intervalles, chez les patients DbT1. 2) Comparer la performance de deux SSCG, Dexcom et Enlite, au repos et pendant l’exercice. Résultats : 1) Avec le système à simple-hormone comparé au double-hormone, 31,2% des participants ont eu au moins un épisode d’hypoglycémie nécessitant un traitement par glucides vs. 9% (p=0,02) et 24,4 ± 27,6 % de temps était passé en hypoglycémie (glucose plasmatique < 4 mmol/l) vs. 4,4 ± 14,3% (p=0,0001), respectivement. 2) Les moyennes de différence relative absolue par rapport au glucose plasmatique pour Dexcom vs. Enlite étaient comparables au repos 13,8 vs. 12,4% (p=0,53) et pendant l’exercice 22,5% vs. 20,4% (p=0,58). La comparaison repos vs exercice était significatif pour Dexcom (p=0,005) et Enlite (p=0,007). Conclusions : le pancréas artificiel à double-hormone engendre un moindre risque d’hypoglycémie et permet un meilleur contrôle de la glycémie que le système à simple-hormone. Les deux SSCG, Dexcom et Enlite ont une bonne performance, sont comparables, mais sont tous les deux moins précis durant l’exercice qu’au repos. / Background: Physical activity is often avoided by patients with Type 1 diabetes (T1D) despite its health benefits due to fear of its elevated hypoglycemic risk. The external artificial pancreas is a new technology that controls glucose via a closed-loop strategy of three components; a continuous glucose monitoring system (CGMS), an algorithm and an insulin pump. Studies of the artificial pancreas included physical activity sessions but were rarely designed to specifically assess its efficacy during exercise. Moreover, the precision of the CGMS can be affected by the rapidly changing blood glucose levels during exercise. Objectives: 1) To test and compare the efficacy of the two versions of the artificial pancreas, single-hormone (insulin only) and dual-hormone (insulin plus glucagon) during two types of exercise, continuous and interval, in patients with T1D. 2) To compare the performance of two CGMS, Dexcom and Enlite, at rest and during exercise. Results: 1) During single-hormone artificial pancreas in comparison to dual-hormone, 31.2% of the participants had at least one hypoglycemic episode necessitating treatment vs. 9% (p=0,02) and 24.4 ± 27.6 % of the time spent in hypoglycemia (plasma glucose < 4 mmol/l) vs. 4.4 ± 14.3% (p=0.0001), respectively. 2) The mean relative absolute differences (MARD) in reference to plasma glucose for Dexcom vs. Enlite were at rest 13.8 vs. 12.4% (p=0.53) and during exercise 22.5% vs. 20.4% (p=0.58). The comparison of mean ARD`s at rest vs. exercise were significant for Dexcom (p=0.005) and Enlite (p=0.007). Conclusions: The dual-hormone artificial pancreas was shown to be better than single-hormone at achieving hypoglycaemia-free control during exercise in adults with T1D. Dexcom and Enlite demonstrated comparable overall performances during rest and physical activity with a lower accuracy for both sensors during exercise.
12

Optimisation du contrôle glycémique des patients atteints de diabète de type 1 : traitement efficace des hypoglycémies, calcul des glucides et pancréas artificiel

Gingras, Véronique 09 1900 (has links)
No description available.
13

Enjeux éthiques et psychosociaux soulevés par le pancréas artificiel

Quintal, Ariane 08 1900 (has links)
Le pancréas artificiel, une technologie médicale portative, est développé pour simplifier et améliorer la gestion et le contrôle du diabète de type 1. Il est constitué de deux dispositifs médicaux déjà commercialisés, soit la pompe à insuline et le lecteur de glycémie en continu. Un logiciel spécialisé, qui est la composante innovante de ce système, ajuste automatiquement les infusions d’insuline de la pompe à insuline aux lectures prises par le lecteur de glycémie en continu. Comme toute technologie médicale, le pancréas artificiel engendre des enjeux psychosociaux et éthiques qui influenceront son succès clinique auprès des personnes atteintes du diabète de type 1, mais ces enjeux n’ont pas été suffisamment approfondis. Ainsi, ce projet de recherche a pour objectif d’identifier et de caractériser les enjeux psychosociaux et éthiques soulevés par le pancréas artificiel. Pour y parvenir, nous avons effectué une analyse éthique de la littérature biomédicale sur le pancréas artificiel suivie d’une étude qualitative des perspectives de personnes atteintes du diabète de type 1 sur cette technologie. Les enjeux psychosociaux et éthiques identifiés par l’analyse éthique et l’étude qualitative se regroupent en cinq catégories : (1) le partage du contrôle du diabète de type 1 avec le pancréas artificiel, (2) l’image corporelle et la corporalité, (3) l’encadrement optimal et les attentes réalistes, (4) l’accès au pancréas artificiel et (5) la confidentialité, la sécurité et la sûreté. Puisque ces enjeux influenceront le succès du pancréas artificiel, ils sont pertinents pour les professionnels de la santé, les développeurs de la technologie et les décideurs publics. / The artificial pancreas, a wearable medical technology, is being developed to simplify and improve type 1 diabetes management and control. It includes two medical devices that are already available on the market, notably the insulin pump and the continuous glucose monitor. Its innovative component is a software that automatically adjusts the insulin pump’s infusions to the continuous glucose monitor’s glycaemic readings. As with any other medical technology, the artificial pancreas likely raises psychosocial and ethical issues that could impact its clinical success among people with type 1 diabetes, but these issues have not been extensively studied. Consequently, the objective of this research project is to identify and characterize the psychosocial and ethical issues that could be raised by the artificial pancreas. To this end, we conducted an ethical analysis of the biomedical literature followed by a qualitative study of the perspectives of people with type 1 diabetes on this technology. The psychosocial and ethical issues identified through the ethical analysis and the qualitative study are grouped under five categories: (1) shared control of type 1 diabetes with the artificial pancreas, (2) body image and embodiment, (3) optimal support and realistic expectations, (4) access to the artificial pancreas, and (5) confidentiality, security, and safety. As these issues may influence the success of the artificial pancreas, they are relevant to healthcare professionals, technology developers, and policymakers.
14

Gestion de diabète insulino-traité et hypoglycémie : rôle de la technologie et révision des recommandations de traitement

Taleb, Nadine 11 1900 (has links)
Vivre avec une maladie chronique a des implications multiples sur une personne atteinte et ses proches. Ces implications sont majeures en cas de diabète insulino-traité comme le diabète de type 1 (DT1) et le diabète de type 2 avancé (DT2). Bien qu’un contrôle glycémique optimal soit indispensable pour prévenir et ralentir les complications micro-vasculaires chroniques, l’atteinte d’un tel objectif avec l’intensification de l’insulinothérapie se heurte à un risque important d’hypoglycémie. Les progrès technologiques : pompes à insuline, systèmes de surveillance de la glycémie interstitielle en continu (SSGC) et couplage de ces dispositifs avec un algorithme dans les systèmes de pancréas artificiel (PA) mono-hormonal avec insuline seule, ou bi-hormonal avec ajout de glucagon permettent de plus en plus de rendre le traitement plus simple (automatisation), plus efficace (moins d’hyperglycémies) et plus sûr (moins d’hypoglycémies). Cependant ces technologies apportent de nouveaux défis que nous avons explorés. À travers les projets de cette thèse : 1) Nous avons exploré la gestion de diabète avec le recours à la technologie de point de vue des utilisateurs actuels pour les pompes et les utilisateurs potentiels futurs pour les systèmes PA. Nos questionnaires ont mis l’accent sur l’enthousiasme des patients pour l’adoption de ces technologies et la perception positive de leur rôle dans le contrôle glycémique et la réduction de la glycémie; toutefois, plusieurs problèmes techniques ont été rapportés avec les pompes (nécessitant une amélioration de la technologie, un meilleur recensement ou une meilleure évaluation des effets indésirables) et une préférence d’être capable au besoin d’ignorer les recommandations du PA. 2) Nous avons testé pour la première fois le système PA développé à Montréal pour les patients vivant avec un DT2 insulino-traité et démontré son applicabilité pour cette population avec amélioration du contrôle glycémique en comparaison aux traitements conventionnels ouvrant la porte aux études plus vastes en vie réelle. 3) Trois stratégies en PA ont été aussi testé pour la première fois pour améliorer le contrôle glycémique pendant l’exercice pratiqué dans la période postprandiale (une situation d’hyperinsulinémie et variations rapides de la glycémie). Nous avons comparé : a) un contrôle glycémique exclusivement basé sur les données de la SSCG, b) une annonce avant le repas visant une glycémie plus haute et c) une annonce combinant la réduction du bolus du repas avec la cible glycémique plus haute. L’option qui consiste à annoncer l’exercice avant le repas à l’algorithme en combinant une cible glycémique plus haute avec une réduction de tiers du bolus prandial constituait l’approche la plus pratique pour éviter les hypoglycémies pendant un exercice d’intensité modérée pour 1h débuté 90 minutes post-repas. 4) Le système PA bi-hormonal est avantageux pour la réduction de l’hypoglycémie mais la formulation actuelle du glucagon présente la problématique de la stabilité avec une recommandation d’utilisation immédiate. Nous avons démontré sa stabilité pour 24 heures en contexte de PA ce qui permet de mener des études pour explorer le bénéfice du PA bi-hormonal. 5) Nous avons également exploré la question de sécurité de cette nouvelle utilisation du glucagon en mini-bolus et de façon chronique et nous avons proposé une liste de paramètres à surveiller dans les études prolongées compte tenu l’effet pléiotropique du glucagon sur la majorité des organes. 6) Nous avons démontré que le traitement des épisodes d’hypoglycémie non-sévères résiduels qui surviennent lors du traitement par PA restent difficiles à traiter avec seulement 17% des épisodes corrigés 15 min après l’ingestion des 15 grammes de glucides tel que recommandé. 7) Nous avons finalement exploré si le traitement des épisodes d’hypoglycémies non sévères pourrait être modulé en fonction du seuil glycémique atteint et de la quantité initiale des glucides consommés. Nous avons alors testé l’ingestion de 16 g de glucides (selon les recommandations) contre 32 g de glucides (plus représentatif des pratiques des patients) à deux seuils d’hypoglycémie (3,0 à 3,5 mmol/L et  3,0 mmol/L). Nos résultats confirment la difficulté de traitement de ces épisodes (lenteur de la correction et besoin fréquent de second traitement) quel que soit le seuil de traitement et/ou la dose initiale de glucides consommés. Ainsi, nous avons démontré les avantages et les limites de la technologie pour le diabète insulino-traité, y compris les systèmes PA, en allant de la préférence des patients pour la technologie, à l’utilité du PA dans le DT2 avancé, à la nécessité de annoncer l’exercice à l’algorithme avant le repas pour l'exercice postprandial, à la stabilité de la formulation disponible du glucagon et les paramètres cliniques à surveiller dans les essais à long terme du PA. Cette thèse a finalement montré le manque d’efficacité du traitement de l'hypoglycémie non-sévère par consommation de glucides oraux même dans le cadre du PA. / Living with diabetes, a chronic disease, has multiple implications for a person and their loved ones. These implications are major in the case of insulin-treated diabetes such as type 1 diabetes (T1D) and advanced type 2 diabetes (T2D). Although optimal glycemic control is essential to prevent and slow chronic microvascular complications, achieving such a goal through intensive insulin therapy has the drawback of increased risks of hypoglycemia. Technological advances: insulin pumps, continuous glucose monitoring systems (CGMS) and coupling of these devices with an algorithm in artificial pancreas (AP) systems, mono-hormonal (insulin) or bi-hormonal (with glucagon), can make diabetes treatment simpler (automation), more effective (less hyperglycemia) and safer (less hypoglycemia). However, these technologies bring up new challenges that we have explored through the projects of this thesis: 1) We have examined the use of technology in diabetes management from the perspective of current users for insulin pumps and potential future users for AP systems. Our online surveys highlighted the enthusiasm of patients for technology adoption and the positive perception they hold about its role in glycemic management; nevertheless, several technical problems have been reported with insulin pumps (hence the need to improve the identification of adverse events) and a preference to ignore AP recommendations if necessary. 2) We have tested for the first time the mono-hormonal AP system developed in Montreal for patients living with insulin-treated T2D and demonstrated its applicability for this population with improved glucose management in comparison to conventional treatments opening the door to larger studies in real life settings. 3) Three strategies in AP were also tested for the first time to improve glucose management during exercise practiced in the postprandial period (a situation of hyperinsulinemia and rapid changes in blood sugar). We compared: a) glycemic control based exclusively on CGMS data, b) a pre-meal announcement of exercise to the algorithm that increases target glucose levels, and c) a combination of exercise announcement with meal bolus reduction. The last strategy offered the most practical approach to avoid hypoglycemia during moderate-intensity aerobic exercise of one hour duration that is practiced 90 minutes post-meal. 4) The bi-hormonal AP system is advantageous for the reduction of hypoglycemia but the current commercial glucagon formulation (lyophilized powder) is not stable in liquid form and is only approved for immediate use post reconstitution in an acid solution. We have however demonstrated its stability for 24 hours in the context of AP use (mini-boluses through pumps), which makes it possible to conduct studies to explore the benefit of bi-hormonal AP until new stable formulations are approved. 5) We have also explored the question of the safety of this new use of glucagon in mini-bolus and in chronic way. We have proposed a list of parameters to be monitored in prolonged bi-hormonal AP studies given the pleiotropic effect of glucagon on the majority of organs. 6) We have demonstrated that during AP control (mono-or bi-hormonal), residual non-severe hypoglycaemic episodes remain difficult to treat with a resolution of only 17% of these episodes 15 min after ingestion of the recommended 15 grams of carbohydrates (CHO). 7) We have finally investigated whether non-severe hypoglycaemia treatment with oral CHO could be modulated according to the hypoglycemia threshold reached and the initial amount of CHO consumed. We have thus tested 16 g CHO (recommended by guidelines) versus 32 g CHO (closer to patients’ practices) at two hypoglycemia thresholds (3.0- 3.5 mmol/L and  3.0 mmol/L). Our results confirm the difficulty of treating these episodes (slow correction and frequent need for a second treatment) regardless of the treatment threshold and/or initial CHO dose consumed. Therefore, we have demonstrated the advantages and limits of technology in insulin-treated diabetes including AP systems, by revealing the preferences of patients for technology use, the usefulness of AP in insulin treated T2D, the need of pre-meal announcement to the algorithm during postprandial exercise, the stability of commercial glucagon formulation and the clinical parameters to be monitored in long-term trials. This thesis finally showed the compromised efficacy of non-severe hypoglycaemia treatment with recommended oral CHO even in the context of AP.
15

New Contributions Towards Meal and Exercise Announcement-Free Artificial Pancreas Systems

Sala Mira, Iván 03 April 2023 (has links)
[ES] Las infusiones exógenas de insulina son vitales para las personas con diabetes tipo 1 para suplir parcialmente la incapacidad del páncreas de secretar insulina. Sin embargo, las terapias intensivas actuales pueden restringir la calidad de vida de los pacientes. Los pacientes con esta enfermedad tienen que tomar decisiones constantemente sobre las dosis de insulina que lleva a la glucosa a niveles seguros. Si no lo consiguen, pueden sufrir las complicaciones crónicas y agudas derivadas de los niveles anormalmente altos o bajos de glucosa. La regulación automática de glucosa con sistemas de páncreas artificial prometía reducir la carga del autocontrol de la enfermedad al mismo tiempo que se mejoraba el tiempo en normoglucemia y se reducía la variabilidad. Sin embargo, estas promesas sólo se han cumplido parcialmente. Aunque esta tecnología mejora el control glucémico que logran las terapias tradicionales, la ingesta de alimentos y la práctica de ejercicio limitan la eficiencia de los sistemas de páncreas artificial durante el día. De hecho, los sistemas comerciales sólo pueden hacerles frente con la ayuda de los pacientes. Para compensar las ingestas, los pacientes deben anunciar el contenido de carbohidratos al sistema. Para el ejercicio, deben anunciar el inicio de la actividad o tomar medidas preventivas como modificar la referencia de glucosa o reducir la basal con mucha antelación. Estas exigencias no sólo no ayudan a reducir la carga del paciente, sino que pueden comprometer la eficiencia del sistema cuando el paciente se equivoca al estimar los carbohidratos, omite el anuncio de la comida o no puede planificar el ejercicio. Así pues, esta tesis propone nuevos métodos para eliminar el anuncio de ingestas y ejercicio lo que ayudaría a reducir la intervención del paciente en los sistemas de páncreas artificial, y, en consecuencia, mejorar la calidad de vida. Desde un punto de vista de control, las ingestas y el ejercicio pueden considerarse perturbaciones. Esta tesis explota métodos de la literatura de rechazo de perturbaciones y acomodación de fallos para lograr el objetivo de la tesis. En concreto, hay que destacar tres aplicaciones: 1) se ha desarrollado un observador super-twisting para detectar comidas no anunciadas como primer paso para su compensación; 2) se ha diseñado un observador de modos deslizantes de primer orden para la estimación de la ratio de aparición de glucosa, la cual ha sido integrada en un generador de bolos para compensar las comidas; 3) se ha empleado el principio de diseño por modelo interno para mitigar el efecto de las ingestas de alimentos y ejercicio, añadiendo sugerencias de carbohidratos de rescate a la insulina. Como resultado, las contribuciones de esta tesis allanan el camino para el desarrollo de sistemas de páncreas artificial sin anuncios, que liberen al paciente de la carga de la gestión de la diabetes. / [CA] Les infusions exògenes d'insulina són vitals per a les persones amb diabetis tipus 1 per a suplir parcialment l'incapacitat del pàncrees de secretar insulina. No obstant, les teràpies intensives actuals poden restringir la qualitat de vida dels pacients. Les persones amb aquesta malaltia han de prendre decisions contínuament sobre la dosi d'insulina que fa que la glucosa estiga en valors segurs. Si no ho aconsegueixen, poden sofrir les complicacions cròniques i agudes derivades dels nivells anormalment alts o baixos de glucosa. La regulació automàtica de glucosa amb sistemes de pàncrees artificials prometia reduir la càrrega d'autocontrol de la malaltia al mateix temps que es millorava el temps en normoglucèmia i es reduïa la variabilitat. No obstant, aquestes promeses s'han complit només parcialment. Encara que aquesta tecnologia millora el control de la glucosa, la ingesta d'aliments i la pràctica d'exercici limiten l'eficiència dels sistemes de pàncrees artificials durant el dia. De fet, els sistemes comercials només poden fer-les front amb la ajuda dels pacients. Per a compensar les ingestes, el pacients han d'anunciar al sistema la quantitat de carbohidrats. Per al exercici, han d'anunciar l'inici de l'activitat o prendre mesures preventives com modificar la referència de glucosa o reduir la infusió basal d'insulina. Aquestes exigències no només no ajuden a reduir la càrrega al pacient, sinó que poden comprometre l'eficiència del sistema quan el pacient confon la estimació dels carbohidrats, omet l'anunciament de la ingesta o no pot planificar l'exercici. Així doncs, aquesta tesi proposa nous mètodes per a eliminar l'anunciament d'ingestes i exercici permetent reduir així la intervenció del pacient, i, en conseqüència, millorar la qualitat de vida. Des del punt de vista de control, les ingestes i el exercici poden considerar-se pertorbacions. Aquesta tesi explota mètodes de la literatura de rebuig de pertorbacions i acomodament de fallades. En particular, es destaquen tres aplicacions: 1) s'ha desenvolupat un observador super-twisting per a detectar ingestes no anunciades com a primer pas per a la seua compensació; 2) se ha dissenyat un observador de modes lliscants per a estimar el rati d'aparició de glucosa de la ingesta, el qual s'ha integrat en un generador de bols d'insulina per compensar les ingestes; 3) se ha empleat el principi de disseny per model intern per a mitigar l'efecte de les ingestes i exercici, incorporant recomanacions de carbohidrats a la insulina. Com a resultat, les contribucions d'aquesta tesi obren el camí per a desenvolupar sistemes de pàncrees artificial sense anunciaments, que alliberen al pacient de la càrrega de la gestió de la diabetis. / [EN] Exogenous insulin infusions are vital for people with type 1 diabetes to partially make up for the inability of the pancreas to secrete insulin. However, current intensive therapies may restrict patients' quality of life. People with this disease have to constantly make decisions about insulin doses to bring glucose levels to a safe range. If unsuccessful, they may suffer from chronic and acute complications related to abnormally high and low glucose values. The automatic regulation of glucose with artificial pancreas systems promised to reduce patients' self-control burdens while improving time in normoglycemia and decreasing variability. However, these promises are fulfilled only partially. Although this technology outperforms the glycemic outcomes achieved by conventional therapies, meal intake and physical activity limit its daytime performance. Indeed, commercially available systems only can handle them with the support of the patients. For meals, patients must announce the carbohydrate content to the system. For exercise, they must notify the activity or take preventive actions like changing glucose setpoint or decreasing basal well ahead before exercise. These demands do not help reduce the patient's burden. They even can compromise the system performance when the patient misestimates the carbohydrate content, omits the meal announcement, or cannot plan the exercise event. Hence, this thesis proposes new methods to eliminate the need for meal and exercise announcements, thus reducing patient intervention in artificial pancreas systems for a better quality of life. From a control perspective, meals and exercise can be regarded as disturbances; therefore, this thesis exploits methods from the disturbance rejection and fault accommodation literature to achieve the thesis goal. Specifically, the following three applications must be highlighted: 1) a super-twisting-based residual generator has been developed to detect unannounced meals as the first step to their compensations; 2) a sliding-mode disturbance observer has been designed to estimate the glucose meal appearance, which is fed into a bolusing algorithm to compensate the meals; 3) the internal model principle is employed to mitigate the effects of meal intakes and exercise, supplementing insulin infusions with carbohydrate recommendations. As a result, the contributions of this thesis pave the way for the development of announcement-free artificial pancreas systems, releasing patients from the burden of diabetes management. / This work was partially supported by: grant DPI2016-78831-C2-1-R funded by MCIN/AEI/10.13039/501100011033 and by “ERDF A way of making Europe”; grant PID2019-107722RB-C21 funded by MCIN/AEI/10.13039/501100011033; and grant ACIF/2017/021 funded by the Generalitat Valenciana through European Social Funds (FSE). Also, the grant BEFPI/2019/077, funded by the Generalitat Valenciana through FSE funds, supported a 7-month research stay at Physiological da University (Óbudai Egyetem, Óbuda, Budapest, Hungary) / Sala Mira, I. (2023). New Contributions Towards Meal and Exercise Announcement-Free Artificial Pancreas Systems [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/192684

Page generated in 0.0982 seconds