• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 110
  • 1
  • Tagged with
  • 111
  • 111
  • 100
  • 95
  • 48
  • 43
  • 40
  • 32
  • 28
  • 22
  • 15
  • 12
  • 12
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo histomorfométrico da ação do laser de baixa potência na reabsorção radicular ortodonticamente induzida em ratos / Histomorphometric study of low-level laser action on orthodontic induced root resorption

Eliziane Cossetin Vasconcelos 27 February 2013 (has links)
A reabsorção radicular inflamatória induzida pela movimentação dentária é uma consequência da lesão dos cementoblastos devido à aplicação da força sobre o dente deixando a raiz exposta à ação dos osteoclastos. Estudos vêm sendo feitos a fim de se desenvolver um meio de evitar, controlar ou reduzir este tipo de reabsorção. A fototerapia com laser tem demonstrado efetividade como agente antiinflamatório e, considerando a origem inflamatória desta patologia este estudo se propôs a avaliar a ação do laser sobre as reabsorções radiculares. Para isto realizou-se uma análise histomorfométrica da raiz disto-vestibular dos primeiros molares superiores de ratos após a indução da sua movimentação mecânica, sendo irradiados ou não com laser de baixa potência. Para a fototerapia foi utilizado um laser diodo, calibrado com comprimento de onda de 808 nm, potência de saída de 100mW, energia total de 2,1J ou 96J e área de 0,0028cm2. A aplicação foi contínua, pontual e com contato. Foram utilizados 54 ratos Wistar, machos, com aproximadamente 80 dias, pesando entre 280±40g. Para a movimentação utilizou- se uma mola fechada super-elástica, com força constante, pré-calibrada em 25g. Os espécimes foram irradiados a cada 48 horas conforme o grupo a que pertenciam. O sacrifício se procedeu no sétimo ou décimo dia após o início da movimentação. O exame histológico foi realizado com cortes de 6 μm corados em HE. Os resultados revelaram que, com as dosimetrias estudadas, o laser de baixa potência, não teve efeito estatisticamente significante sobre as reabsorções radiculares. Concluindo-se que não há diferença na área reabsorvida, espessura ou extensão da reabsorçãoradicular entre os grupos controle e experimental. / Inflammatory root resorption induced by tooth movement is a consequence of the cementoblasts injury due to application of force on the tooth leaving the root exposed to the action of osteoclasts. Studies have been made to develop a means of preventing, controlling or reducing this kind of resorption. Phototherapy by laser has demonstrated effectiveness as an antiinflammatory and considering the inflammatory origin of this pathology this study evaluated the effects of laser on root resorption. For this we carried out a histomorphometric analysis of maxillary first molars distobuccal root of rats after being moved, irradiated or not with low-level laser. Order to phototherapy it was used a diode laser, calibrated with a wavelength of 808 nm, output power of 100mW, 2.1J or 96J of energy and area of 0.0028 cm2. The application was continuous, punctual and with contact. It was used 54 male Wistar rats, approximately 80 days, weighing 280 ± 40g. For tooth movement, it was used a super elastic closed spring, with pre-calibrated and constant force of 25g. The specimens were irradiated every 48 hours depending on the group they belonged to. The sacrifice was made in the seventh or tenth day after the onset of movement. Histological examination was performed with sections of 6 μm stained with HE. The results revealed that, considering the dosimetry studied, low-level laser, has no effect statistically significant on the root resorption. Concluding it does not have difference in the root reabsorption area, thickness or extension, between the control and the experimental groups.
12

Circuitos Multiplicadores Array de Baixo Consumo de Potência Aplicados a Filtros Adaptativos / Low-Power Array Multipliers Circuits for Adaptive Filter

Pieper, Leandro Zafalon 08 August 2008 (has links)
Made available in DSpace on 2016-03-22T17:26:08Z (GMT). No. of bitstreams: 1 leandro zafalon.pdf: 1268402 bytes, checksum: cd35030285126fa95b61d98c6a518798 (MD5) Previous issue date: 2008-08-08 / The main goal of this work is the implementation and analyzes of new array multiplier architectures. These new architectures were recently presented in the scientific community by including different power reduction techniques, such as the use of efficient adder circuits and the optimization of the dedicated multiplication structures that allow the multiplication operation in the radix 2m. The new multipliers operate in 2´s complement and keep the same regularity presented by a conventional array multiplier. The architectures operate in the radix 2m, where m represents the group of bits multiplied at a time. In a conventional array multiplier, where the multiplication is performed bit by bit, m assumes value equal 1 (radix 2 operation). In this work, the new multiplier architectures operate in different radices, leading to a reduction in the number of partial product lines, enabling higher performance and power reduction in the multipliers. The 16, 32 and 64 bit width multipliers were described in textual language (gate level), and the comparisons between the multipliers are preformed in terms of area, delay and power consumption by using SIS environment (for area and delay results) and SLS tool (for power consumption estimation). In this work we have applied the proposed optimized multipliers in digital filtering algorithms such as finite impulse response (FIR) and dedicated architecture for the LMS (Least Mean Square) adaptive filtering / O objetivo principal deste trabalho é a implementação e análise de novas arquiteturas de circuitos multiplicadores array digitais recentemente apresentados no meio cientifico com diferentes técnicas de redução de potência, tais como a utilização de eficientes estruturas de circuitos somadores, bem como a otimização dos blocos dedicados de multiplicação, que permitem a operação de multiplicação na base 2m. A proposta de novas arquiteturas consiste em operações de multiplicação em complemento de 2 e que mantenham a mesma regularidade de um multiplicador array convencional. As arquiteturas podem operar com números na base 2m, onde m representa o grupo de bits de multiplicação. Em um multiplicador array convencional, onde a operação de multiplicação é realizada bit a bit, o valor de m é igual a 1 (operação na base 2). Neste trabalho, são apresentadas novas arquiteturas de multiplicadores que operam em diferentes bases, o que permite a redução do número de linhas de produtos parciais, com impactos diretos no aumento de desempenho e redução do consumo de potência. A implementação dos diferentes circuitos multiplicadores foi realizada no nível textual (nível de portas lógicas), onde circuitos multiplicadores de 16, 32 e 64 bits são comparados em termos de parâmetros de área, atraso e consumo de potência utilizando os ambientes SIS (para valores de área e atraso) e SLS (para estimação de valores de consumo de potência). Como estudos de caso, as diferentes arquiteturas de circuitos multiplicadores propostas neste trabalho foram aplicadas em filtros digitais de resposta finita ao impulso (FIR) e em arquitetura dedicada de algoritmo de filtragem adaptativa LMS (Least Mean Square)
13

Síntese de controladores síncronos com redução da atividade do relógio.

Leonardo Romano 28 July 2010 (has links)
Os projetistas de sistemas digitais por várias décadas se preocupavam somente com redução de área e aumento de desempenho ligado ao tempo de ciclo. Devido a alta integração da tecnologia VLSI onde a elevada dissipação de potência é prejudicial, a alta demanda por eletrônica móvel e também o aumento do custo de energia. Os projetistas dos sistemas digitais síncronos contemporâneos começaram a se preocupar com a potência consumida em seus projetos. Nas duas ultimas décadas, diferentes técnicas foram propostas para redução da potência consumida nas várias etapas do projeto digital. Na etapa de síntese lógica, duas técnicas voltadas para máquinas de estado finito (MEF) modelo Moore (controladores síncronos) tiveram resultados interessantes. Na primeira, o relógio é inibido quando a MEF encontra uma auto-transição. E a segunda, implementa MEF com flip-flops que operam nas duas bordas do relógio (double-edge triggered - DET-FF). Elementos de memória DET-FF não estão disponíveis em bibliotecas básicas standard cell e não são usados nas macro-células dos dispositivos programáveis. Projetos propostos de DET-FF ocupam maior área e consomem maior energia, quando comparados com os flip-flops convencionais (single-edge triggered - SET-FF). Esta tese propõe um método de assinalamento de estados e uma arquitetura alvo para MEF modelo Moore que inibe o relógio nas auto-transições e opera nas duas bordas do sinal de relógio. Permitindo a MEF operar com a metade da freqüência, mas potencialmente com o mesmo tempo de latência. O algoritmo de assinalamento de estado proposto particiona as variáveis de estado possibilitando somente o uso de elementos de memória SET-FF. Foi desenvolvida uma ferramenta de síntese que incorpora as propostas da arquitetura alvo e do algoritmo de assinalamento de estados. Ela foi aplicada em um conjunto de vinte benchmarks onde se constatou uma penalidade em área de 4 % de 7,04% em portas e uma redução de 27,05% em potência consumida.
14

Desenvolvimento de sequências de pulso de eco de spin de baixa potência para RMN on-line / Low-power Spin echo pulse sequences to NMR online

Andrade, Fabiana Diuk de 20 May 2011 (has links)
A Ressonância Magnética Nuclear em baixa resolução (RMN-BR) vem sendo aplicada no controle e certificação de qualidade na indústria. Para acelerar e automatizar as análises tem sido proposto o uso de RMN online, com carreamento de amostras por uma esteira. Apesar do grande potencial, as metodologias utilizadas podem provocar o aquecimento da amostra, causando erros nas medidas, além de reduzir a vida útil do equipamento. Assim, nesse trabalho de doutorado foram desenvolvidas sequências de eco de spin para medidas de RMN-BR online utilizando baixa potência de RF (radiofrequência), baseadas nas técnicas CP, Carr-Purcell, e CPMG, Carr-Purcell-Meiboom-Gill, utilizando baixos ângulos de refocalização, LRFA (Low Refocusing Flip Angle). Observou-se que LRFA de 45&deg; (CPMG45) pode fornecer valores de tempo de relaxação transversal (T2) com erros inferiores a 5% em campos magnéticos (B0) com homogeneidade equivalente a largura de linha de &Delta;&nu; &le; 15 Hz. Em B0 menos homogêneos (&Delta;&nu; &ge; 100 Hz), a escolha dos LRFA deve considerar a redução do sinal e o aumento de T2, que se torna dependente do tempo de relaxação longitudinal (T1). CP90 produz ecos entre os pulsos de refocalização que decaem para valores mínimos dependente de T2* (constante de tempo do Decaimento Livre da Indução). O sinal obtido por CP90 aumenta de valores mínimos para o regime de estado estacionário (EE) com constante de tempo T* = 2T1T2/(T1+T2) e amplitude MCP90 = M0T2/(T1+T2), a mesma constante e a mesma amplitude observada para o sinal de Precessão Livre em Onda Contínua (CWFP - Continuous Wave Free Precession), por isso foi denominada CP-CWFP. A principal vantagem de CP-CWFP ocorre para amostras com T1 ~ T2. CP-CWFP apresenta um decaimento abrupto da amplitude do sinal antes de aumentar e alcançar o EE. Essa diferença na amplitude torna o ajuste de T* menos dependente da razão sinal/ruído, sendo mais eficiente que CWFP para medidas de T1 e T2 em B0 baixos, onde T1 e T2 tendem a ter valores similares. No método de alternância de fase (AF) em CPMG90AF (y\'/-y\') e CP90AF (x\'-x\') os sinais entraram num EE, nesse caso CPMG90AF e CP90AF tiveram comportamentos similares ao CP-CWFP, sendo mais uma alternativa para obtenção de T1 e T2. Para CPMG, a redução do ângulo de refocalização para 90&deg; equivale a uma redução de 75% da potência incidida na amostra. CP-CWFP pode ser uma técnica mais robusta para análises em espectrômetros de RMN de bancada em controle de qualidade industrial, com B0 < 0,5 T (20 MHz) e em ferramentas de RMN utilizadas em poços de petróleo com B0 ~ 0,05 T (2 MHz). As análises por métodos estatísticos demonstraram que CPMG e CPMG90, CWFP e CP-CWFP apresentam alta correlação entre si, demonstrando que uma técnica pode substituir a outra nas análises online de sementes oleaginosas. / Low Resolution Nuclear Magnetic Resonance (LR-NMR) has been applied in quality control and certification in industry. To speed up the analysis the online NMR has been proposed. Despite LR-NMR online potential, some problems related to equipment overload occurs. It is due to methodologies used that can cause an increase in sample temperature and consequently errors in measurements as well reduction on equipment durability. Thus, Carr-Purcell, CP and Meiboom-Gill, CPMG using low refocusing flip angles (LRFA) were developed. It was observed that LRFA as low as 45&deg; (CPMG45) can provide transverse relaxation time values (T2) with errors below 5% for homogeneous field (&Delta;&nu; &le; 15Hz). For a less homogeneous magnetic field (&Delta;&nu; &ge; 100 Hz) the choice of the LRFA has to take into account the reduction in the intensity of the CPMG signal and the increase in the time constant of the CPMG decay that also becomes dependent on longitudinal relaxation time (T1). The Carr-Purcell (CP) pulse sequence, with LRFA, produces echoes midway between refocusing pulses that decay to a minimum value dependent on T2* (Free Induction Decay time constant - FID). When &tau; &gt; T2*, the signal increased to reach a Steady-State Free Precession regime (SSFP) after the minimum value and was composed of FID signal after each pulse and an echo, before the next pulse. CP90 signal increased from the minimum value to the steady-state regime with a time constant (T*) = 2T1T2/(T1+T2), identical to the time constant observed Continuous Wave Free Precession (CWFP). The Steady-State amplitude obtained with CP90 (MCP90) = M0T2/(T1+T2) was identical to CWFP. Therefore, this sequence was named CP-CWFP because it is a CP sequence that produces results similar to the CWFP. However, CP-CWFP is a better sequence than CWFP for measuring the longitudinal and transverse relaxation times in single scan, when the sample exhibits T1 ~ T2. When phase alternation is applied in CPMG90AF (y\'/-y\') e CP90AF (x\'-x\') the signal reaches a Steady-State. CPMG90AF and CP90AF showed similar behavior to CP-CWFP, so one more alternative method to measure T1 and T2. Therefore, the T2 measurements can be performed with 90&deg; refocusing pulses (CPMG90), which use only 25% of the RF power used in conventional CPMG. This reduces the heating problem in the probe and reduces the power deposition in the samples. The CP-CWFP sequence can be a useful method in low-resolution NMR and can be widely used in the agriculture, food and petrochemical industries because those samples tend to have similar relaxation times in low magnetic fields.
15

Avaliação da resistência adesiva à dentina tratada pela terapia fotodinâmica em dente bovino / Evaluation of the bond strength to dentin treated by photodynamic therapy in bovine tooth

Bernal Rodriguez, Christian Giancarlo 17 January 2017 (has links)
A Terapia fotodinâmica (TF) é uma técnica que combina a ativação de um fotossensibilizador por luz na presença de oxigênio, produzindo radicais que induzem a morte celular dos microrganismos. Esta terapia vem sendo usada para reduzir a quantidade de microrganismos sendo um potencial antimicrobiano nos tecidos cariados em um processo restaurador direto, evitando assim o processo de cárie recidivante que pode acontecer quando não se promove a eliminação dos restos de microrganismo remanescentes após a utilização dos instrumentos rotatórios. O objetivo deste estudo in vitro foi avaliar a resistência de união de dois sistemas adesivos (condicionamento total e autocondicionante), sobre a superfície de dentina bovina, após tratamento com terapia fotodinâmica. Foi feito ensaio de microcisalhamento com o objetivo de avaliar a resistência de união. Para a realização da terapia fotodinâmica foi usado azul de metileno a 0,01% e duas fontes de luz diferentes, laser vermelho (660 nm) e LED (645-630 nm), com parâmetros já testados em estudos anteriores e, atualmente, utilizados na clinica odontológica. Para avaliar a resistência de união foi utilizado ensaio mecânico de microcisalhamento e, para isso, se utilizou sessenta discos de dentina, obtidos a partir de sessenta incisivos centrais bovino íntegros. Após o desgaste da dentina, as amostras foram dividas aleatoriamente em 6 grupos, sendo n=10 para o ensaio de microcisalhamento (G1: adesivo autocondicionante Single Bond Universal (USB) sem PDT, G2: PDT com laser + USB, G3: PDT com LED + USB; G4: adesivo de condicionamento total com Adper Single Bond 2 (ASB) sem PDT; G5: PDT com laser + ASB¸ G6: PDT com LED + ASB). Em cada amostra foram confeccionados 03 cilindros de resina composta, os quais foram submetidos à avaliação de microcisalhamento (1 mm/min); após armazenamento em saliva artificial por 24 horas. Após este teste, as amostras foram levadas em lupa estereoscópica (40x) para análise do padrão de fratura. Os resultados do teste de resistência de união foram tabulados e submetidos ao teste ANOVA dois fatores (adesivo e tratamento) e Tukey adotando-se um nível de significância de 5%. Quanto à resistência de união, não houve diferença significativa entre os 6 grupos analisados. Houve predominância de padrão de fratura do tipo adesiva. Com base nos resultados e nos parâmetros de irradiação utilizados neste estudo, pode-se concluir que não existe alteração na força de adesão da resina na dentina hígida após tratamento com PDT. / Photodynamic Therapy (PDT) is a technique that combines the activation of a photosensitizer by light in the presence of oxygen, producing radicals that induce cell death of the microorganisms. This therapy has been used to reduce the amount of microorganisms being an antimicrobial potential in the decayed tissues in a direct restorative process, thus avoiding the process of recurrent caries that can happen when the elimination of remaining remains of microorganism after the use of the instruments is not promoted. The objective of this in vitro study was to evaluate the bond strength and morphology of the hybrid layer of two adhesive systems (Self-etch and total etch) on the bovine dentin surface, after treatment with photodynamic therapy. A micro-shear test was performed in order to evaluate the bond strength. To perform the photodynamic therapy, 0.01% methylene blue and two different light sources, red laser (660 nm) and LED (645-630 nm) were used, with parameters already tested in previous studies and currently used in the dental clinic. In order to evaluate the bond strength, a microshear bond strenght test was used. For this purpose, sixty dentin disks were obtained from sixty complete central incisors. After dentin wear, the samples were randomly divided into 6 groups, with n = 10 for the micro bond strenght test (G1: Self-etch adhesive, single bond Universal (USB) without PDT, G2: PDT with laser + USB, G3: PDT with LED + USB; G4: total etch adhesive Single Bond 2 (ASB) without PDT; G5: PDT with laser + ASB¸ G6: PDT with LED + ASB). In each sample, 03 cylinders of composite resin were made, which were submitted to the evaluation of micro-shear strenght test (1 mm / min); after storage in artificial saliva for 24 hours. After this test, the samples were taken in a stereoscopic magnifying glass (40x) for analysis of the fracture pattern. The results of the Microshear bond strength test were tabulated and submitted to ANOVA two-factor test (adhesive and treatment) and Tukey adopting a significance level of 5%. Regarding the bond strength, there was no significant difference between the 6 groups analyzed. There was a predominance of an adhesive type fracture pattern. Based on the results and the irradiation parameters used in this study, it can be concluded that there is no alteration in the adhesion strenght of the resin in a healthy dentin after treatment with PDT.
16

Avaliação in vitro da biomodulação de células de linhagem odontoblástica (MDPC-23) de camundongos com laser de baixa potência / Mouse odontoblastic cell behavior after bioestimulation with low-level laser therapy

Luciana Batista Pereira 22 May 2009 (has links)
O laser de baixa intensidade ou terapêutico promove a biomodulação das respostas reparadoras naturais de células pulpares como os odontoblastos, sendo uma estratégia de tratamento a ser utilizada na terapia pulpar. O objetivo deste estudo foi avaliar in vitro o efeito da irradiação do laser terapêutico de arseniato de gálio e alumínio (GaAlAs) no comportamento da linhagem odontoblástica (MDPC-23) de camundongos. Células odontoblásticas foram plaqueadas na concentração de 104 células/poço (n=5) e submetidas às irradiações nos dias 0, 1, 2 e 3 após o plaqueamento. Foram avaliadas as doses de 0,2 e 1,0 J/cm2 e comparadas ao grupo controle não irradiado. Os parâmetros analisados foram proliferação e viabilidade celular, quantidade de proteína total, atividade de fosfatase alcalina após 3, 7, 10 e 14 dias; detecção e quantificação de matriz mineralizada após 14 dias e quantificação do fator de crescimento VEGF no sobrenadante das culturas após 7 e 10 dias. Imunofluorescência para proteínas colágenas e não-colágenas após 3, 7 e 10 dias foi realizada para verificar sua expressão qualitativa nos grupos propostos. Os resultados mostraram que o laser não afetou a viabilidade celular que ficou acima dos 90% em todos os grupos e períodos experimentais. De modo geral, os grupos irradiados apresentaram redução na proliferação, maior conteúdo de proteína total e maior atividade de ALP em relação ao observado no grupo controle. A marcação com vermelho de alizarina mostrou maior quantidade de áreas nodulares de matriz calcificada no grupo irradiado com 0,2 J/cm2, dados comprovados pela análise quantitativa. Uma maior concentração de VEGF no sobrenadante da cultura foi observada no grupo irradiado com a menor dose. A imunofluorescência revelou que a menor dose favoreceu a secreção de proteínas colágenas e não colágenas Portanto, o laser de baixa potência, dentro dos parâmetros empregados, favoreceu a expressão do fenótipo odontoblástico. / Low-level laser therapy (LLLT) has been studied as a strategy to be used in pulp therapy through biomodulation of its cells, like odontoblasts. The purpose of this investigation was to evaluate the effect of biomodulation on odontoblastic cells using low-level GaAlAs laser. Odontoblastic cells were cultured in a concentration of 104 cells/well (n=5) and submitted to the energy fluencies of 0,2 and 1,0 J/cm2 and compared to control group. There were evaluated cell proliferation and viability, total protein content and alkaline phosphatase activity ( 3, 7, 10 and 14 days), as well as detection and quantification of mineralized nodules after 14 days and VEGF quantification after 7 and 10 days. Immunofluorescence for collagen and non-collagen proteins was performed to verify their qualitative expression in the proposed groups after 3, 7 and 10 days. The results showed that LLLT did not affect cell viability in all the experimental groups. The irradiated cultures presented reduction in the proliferation, higher total protein content and ALP activity compared to the control group. Staining with red alizarin showed greater amount of nodular areas of calcified matrix in the group irradiated with 0,2 J/cm2, data confirmed by quantitative analysis. It was also observed a higher concentration of VEGF in the culture of the cells irradiated with the lowest energy fluence as well as an enhancement of the secretion of collagen and non-collagen proteins revealed through immunofluorescence. It was concluded that therapy with LLLT favors the expression of odontoblastic phenotype.
17

Estudo dosimétrico do efeito do laser de baixa potência na mucosite oral induzida por 5-Fluorouracil em hamsters / Dosimetric study of Low Level Laser Therapy in oral mucositis induced by 5-Fluorouracil in hamsters

Cotomácio, Cláudia Carrara 28 September 2016 (has links)
A Mucosite Oral (MO) é uma consequência debilitante do tratamento oncológico, que pode ser tratada com o uso do laser de baixa potência (LBP). Entretanto, ainda não há consenso na literatura a respeito de parâmetros dosimétricos para o reparo da mucosa oral. Dessa forma, o objetivo do estudo foi comparar diferentes protocolos com laser de baixa potência (FLBP) para o tratamento da MO, através de análises clínicas e histológicas. Quinze hamsters foram usados, em um modelo de indução de MO por 5-Fluorouracil (5-FU) e ranhuras superficiais na mucosa oral, com 7 dias de acompanhamento clínico. Os animais foram divididos em cinco grupos: Controle (C), que recebeu apenas anestesia e o veículo do quimioterápico, Controle-Quimioterapia (CQ) que recebeu anestesia, 5-FU e ranhuras, Laser Protocolo 1 (L1) que recebeu o mesmo do grupo CQ + FLBP 6 J/cm²/0,24 J (um ponto), Laser Protocolo 2 (L2) o mesmo do grupo CQ + FLBP 25 J/cm²/1 J (um ponto) e Laser Protocolo 3 (L3), o mesmo do grupo CQ + FLBP 6 J/cm²/0,96 J (4 pontos de 0,24J). O laser foi utilizado em ?=660 nm, com área do spot de 0,04 cm² e 40 mW de potência. O melhor protocolo de FLBP para manter os graus de MO mais baixos, em relação ao grupo CQ, foi o L1, seguido dos protocolos L2 e L3. Os resultados histológicos demonstraram padrão semelhante entre os grupos L1, L2 e C, com alguns vasos sanguíneos e a presença de um fino epitélio de aspecto contínuo no dia 7. Nossos resultados sugerem que o modo de aplicação do LBP e a energia entregue por área pode interferir na reparação da MO. / Oral mucositis (OM) is a dose-limited debilitating consequence from cancer treatment that could be treated with low level laser therapy (LLLT); however, there is no consensus about its dosimetric parameters for oral mucosa healing. Thus, the aim of this study is to compare different LLLT protocols on the treatment of OM, through clinical and histological analysis. Fifteen hamsters were used, in an induced model of OM by 5-Fluorouracil (5-FU) and superficial scratching in oral mucosa, in seven days of follow-up. The animals were divided into 5 groups: Control (C) which received only anesthesia and chemotherapic vehicle; Control-Chemotherapy (Ch) which received anesthesia, 5-FU and scratches; Laser Protocol 1 (L1) the same as Ch group + LLLT 6 J/cm²/0.24J (one point); Laser Protocol 2 (L2) the same as Ch group + LLLT 25J/cm²/1J (one point); and Laser Protocol 3 (L3) the same as Ch group + LLLT 6 J/cm²/0.96 J (4 points of 0.24J). The laser that was used has ?=660 nm, 0.04 cm² of spot area and 40 mW of power. The best LLLT protocol to maintain lowest OM levels compared to Ch group was L1, followed by L2 and L3. Histological results demonstrated a similar pattern among L1, L2 and C groups, with some blood vessels presence and continuous aspect of a thin epithelium, on day 7. Our results suggest that the application mode of LLLT and the energy delivered per area could interfere in the oral mucositis healing.
18

Estudo histomorfométrico da ação do laser de baixa potência na reabsorção radicular ortodonticamente induzida em ratos / Histomorphometric study of low-level laser action on orthodontic induced root resorption

Vasconcelos, Eliziane Cossetin 27 February 2013 (has links)
A reabsorção radicular inflamatória induzida pela movimentação dentária é uma consequência da lesão dos cementoblastos devido à aplicação da força sobre o dente deixando a raiz exposta à ação dos osteoclastos. Estudos vêm sendo feitos a fim de se desenvolver um meio de evitar, controlar ou reduzir este tipo de reabsorção. A fototerapia com laser tem demonstrado efetividade como agente antiinflamatório e, considerando a origem inflamatória desta patologia este estudo se propôs a avaliar a ação do laser sobre as reabsorções radiculares. Para isto realizou-se uma análise histomorfométrica da raiz disto-vestibular dos primeiros molares superiores de ratos após a indução da sua movimentação mecânica, sendo irradiados ou não com laser de baixa potência. Para a fototerapia foi utilizado um laser diodo, calibrado com comprimento de onda de 808 nm, potência de saída de 100mW, energia total de 2,1J ou 96J e área de 0,0028cm2. A aplicação foi contínua, pontual e com contato. Foram utilizados 54 ratos Wistar, machos, com aproximadamente 80 dias, pesando entre 280±40g. Para a movimentação utilizou- se uma mola fechada super-elástica, com força constante, pré-calibrada em 25g. Os espécimes foram irradiados a cada 48 horas conforme o grupo a que pertenciam. O sacrifício se procedeu no sétimo ou décimo dia após o início da movimentação. O exame histológico foi realizado com cortes de 6 &#x3BC;m corados em HE. Os resultados revelaram que, com as dosimetrias estudadas, o laser de baixa potência, não teve efeito estatisticamente significante sobre as reabsorções radiculares. Concluindo-se que não há diferença na área reabsorvida, espessura ou extensão da reabsorçãoradicular entre os grupos controle e experimental. / Inflammatory root resorption induced by tooth movement is a consequence of the cementoblasts injury due to application of force on the tooth leaving the root exposed to the action of osteoclasts. Studies have been made to develop a means of preventing, controlling or reducing this kind of resorption. Phototherapy by laser has demonstrated effectiveness as an antiinflammatory and considering the inflammatory origin of this pathology this study evaluated the effects of laser on root resorption. For this we carried out a histomorphometric analysis of maxillary first molars distobuccal root of rats after being moved, irradiated or not with low-level laser. Order to phototherapy it was used a diode laser, calibrated with a wavelength of 808 nm, output power of 100mW, 2.1J or 96J of energy and area of 0.0028 cm2. The application was continuous, punctual and with contact. It was used 54 male Wistar rats, approximately 80 days, weighing 280 ± 40g. For tooth movement, it was used a super elastic closed spring, with pre-calibrated and constant force of 25g. The specimens were irradiated every 48 hours depending on the group they belonged to. The sacrifice was made in the seventh or tenth day after the onset of movement. Histological examination was performed with sections of 6 &#x3BC;m stained with HE. The results revealed that, considering the dosimetry studied, low-level laser, has no effect statistically significant on the root resorption. Concluding it does not have difference in the root reabsorption area, thickness or extension, between the control and the experimental groups.
19

Efeitos da irradiação com laser de baixa potência nas glândulas salivares submandibulares de ratas diabéticas induzidas por estreptozotocina / Low-power laser irradiation effects in submandibular glands of streptozotocin-induced diabetic rats

Fukuoka, Cintia Yuki 15 June 2016 (has links)
O diabetes mellitus (DM) pode levar à disfunção das glândulas salivares. A ativação do receptor de produtos finais de glicosilação avançada e de seus ligantes tem sido reportado em várias doenças crônicas, entre estas, a diabetes e suas complicações. Este estudo analisou a expressão do RAGE, proteína do grupo de alta mobilidade B1 (HMGB1) e de produtos de glicosilação avançada (AGE), bem como os efeitos da irradiação com laser de baixa potência (ILBP) em glândulas salivares submandibulares (GSMs) de ratas diabéticas. Ratas Wistar com 12 semanas de vida foram divididas em 3 grupos: controle (C), diabético (D) e diabético com laser (DL). A indução de DM nos grupos D e DL foi realizada com injeção intraperitoneal de estreptozotocina 60 mg/kg de peso corporal, no 1° dia experimental. No 29°dia, os animais do grupo DL receberam a ILBP (660 nm, 70 mW, 20 J/cm² e 0,56 J por ponto), aplicado no total de quarenta pontos cobrindo a área correspondente as GSMs, e os seus efeitos foram avaliados 24 h após a irradiação (eutanásia). As análises de parâmetros metabólicos, histológicos e de marcadores de inflamação, apoptose e proliferação foram realizadas. Nossos achados mostram que a ILBP diminuiu a glicemia das ratas diabéticas irradiadas, melhorando a resistência à insulina (HOMA-IR), sensibilidade à insulina (HOMA-IS) e função de células beta (HOMA-?). Em GSM, o DM parece aumentar a expressão do eixo HMGB1/AGE/RAGE, possivelmente associado à ativação do fator de transcrição nuclear kappa B (NF?B). A ILBP reduziu os marcadores de inflamação, HMGB1 e TNF-? em GSM de ratas diabéticas, e parece regular a expressão de proteínas relacionadas à proliferação e à apoptose, pela via do AMP cíclico, parcialmente mediado por proteína kinase regulada por sinais extracelulares. No entanto, mais estudos são necessários para melhor entender os efeitos do laser neste tecido. / Diabetes (DM) can lead to dysfunction of the secretory capacity in salivary glands. Since the activation of the receptor for advanced glycation end-products (RAGE) and its ligands has been suggested to participate in chronic disorders, such as diabetes and its complications. This study analyzed the expression of RAGE, high mobility group box protein B1 (HMGB1) and advanced glycation end-products (AGEs) were evaluated, as well as the effects of low-power laser irradiation (ILBP), in diabetic submandibular glands (GSM). Wistar rats 12 weeks-old were divided in three groups: control (C), diabetic (D) and diabetic with laser (DL). The D and DL rats were intraperitoneally injected with streptozotocin 60 mg/kg, in the 1st experimental day. On the 29° day, the DL rats received the ILBP (660 nm, 70 mW, 20 J/cm² e 0,56J per point), with a total of forty points covering the GSMs area, its effects were evaluated 24h after irradiation (euthanasia). Metabolic parameters, histology and the inflammatory, apoptosis and proliferation markers were evaluated. Our findings show that ILBP reduced the blood glucose levels of the irradiated diabetic rats, improving their insulin resistance (HOMA-IR), insulin sensitivity (HOMA-IS) e beta cell function (HOMA-?). In GSM, DM seems to upregulate the expression of HMGB1/AGE/RAGE axis, possibly associated with the activation of the nuclear factor kappa-light-chain-enhancer of activated B cells (NF?B). The ILBP reduced the inflammatory markers HMGB1 and TNF-? in diabetic GSM, and seems to regulate the expression of proteins related to proliferation and apoptosis, by cyclic AMP pathway, partially mediated by extracellular signal-regulated kinase. However, more studies are necessary to better understand the laser effects on this tissue.
20

Estudo do efeito analgésico do laser de baixa potência na mialgia dos músculos mastigatórios: estudo clínico randomizado duplo-cego / Study of low power laser analgesic effect in myalgia of the masticatory muscles: Clinical randomized double-blind

Sabrina Araujo Pinho Costa 07 July 2015 (has links)
O presente estudo avaliou a eficácia do laser de baixa potência (LBP) e do placebo no tratamento da mialgia dos músculos mastigatórios. Sessenta pacientes (média de idade de 38,83 anos ± 14,2) com mialgia dos músculos mastigatórios foram selecionados e alocados em 2 grupos, de forma randomizada: Grupo A: pacientes que foram submetidos à aplicação de laser de baixa potência (LBP) na primeira fase e à aplicação de laser placebo na segunda fase e Grupo B: pacientes que foram submetidos à aplicação de laser placebo na primeira fase e à aplicação de LBP na segunda fase. O laser e o placebo foram aplicados pontualmente nos músculos masseter e temporal bilateralmente. A presença e intensidade de dor espontânea (através da escala visual analógica - EVA), dor à palpação (através do algômetro de pressão) e máxima abertura bucal (com paquímetro) foram mensurados. Os dados foram analisados usando os testes Exato de Fisher, teste t e de Mann-Witney, adotando-se p<0,05 como nível de significância. Melhoras estatisticamente significativas foram encontradas para os fatores dor espontânea, dor à palpação total e dor no masseter direito na análise intragrupo e entre grupos. Não foram encontrados efeitos residuais diferentes em nenhum dos indicadores ao compararmos os grupos que receberam ou não o laser. Apenas o masseter direito apresentou diferença estatisticamente significativa quando foi comparada a ordem das aplicações nos grupos que receberam primeiro o laser e depois o placebo versus o grupo que recebeu primeiro o placebo e depois o laser. Esse resultado indica que não existem diferenças entre a ordem de aplicação do laser. Os resultados obtidos sugerem que houve uma melhora significativa na dor medida através da escala de pontos álgicos nos pacientes que receberam o laser, entretanto a auto avaliação de dor medida pelo EVA não foi estatisticamente diferente. Os efeitos residuais e de ordem também não foram estatisticamente significativos. / This study evaluated the effectiveness of low power laser (LBP) and placebo in the treatment of myalgia of the masticatory muscles. Sixty patients (average age of 38.83 years ± 14.2) with myalgia of the masticatory muscles were selected and allocated into 2 groups randomly: Group A: patients who underwent low-power laser application (LBP) in the first phase and the application of laser placebo in the second phase and Group B: patients who were submitted to laser placebo in the first phase and the implementation of LBP in the second phase. The laser and the placebo were applied punctually in the masseter and temporalis muscles bilaterally. The presence and intensity of spontaneous pain (by visual analogue scale - VAS), pain on palpation (through pressure algometer) and maximal mouth opening (with caliper) were measured. Data were analyzed using the Fisher Test, T test and Mann-Whitney, adopting p <0.05 significance level. Statistically significant improvements were found for spontaneous pain, pain on palpation and complete pain in the right masseter in the intra-group analysis and between groups. There were no different residual effects in any of the indicators when comparing the groups with or without the laser. Just the right masseter showed a statistically significant difference when compared with the order of applications in the groups that received first laser and then the placebo versus the group that received placebo first and then the laser. This result indicates that there are no differences between the laser application order. The results suggests that there was a significant improvement in pain measured by the scale of nociceptive points in patients who received the laser, though the self assessment of pain measured by VAS was not statistically different. Residual and order effects were not statistically significant.

Page generated in 0.0636 seconds