• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 2
  • 1
  • Tagged with
  • 15
  • 15
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Système inertiel de stockage d'énergie associé à des générateurs éoliens

Cimuca, Gabriel-Octavian 12 1900 (has links) (PDF)
Le problème majeur associé aux sources d'énergie décentralisées est qu'elles ne participent en général pas aux services système (réglage de la tension, de la fréquence, démarrage en autonome ou black-start, possibilité de fonctionner en îlotage, etc.). Le fait de ne pas participer aux services système amène ce type de source à se comporter comme des générateurs passifs du point de vue électrique. Le réglage de la tension et de la fréquence est dès lors reporté sur les alternateurs classiques. Le taux de pénétration de la production décentralisée, c'est-à-dire la puissance qu'elle génère par rapport à la puissance consommée, doit alors être limité afin de pouvoir garantir la stabilité du réseau dans des conditions acceptables. Ceci est particulièrement vrai pour les sources à énergie renouvelable dont la source primaire est difficilement prévisible et très, comme c'est le cas de l'éolien pour lequel certains retours d'expérience indiquent que lors de taux de pénétration supérieur à 20 ou 30 % des problèmes de stabilité peuvent apparaître. Même si actuellement les éoliennes ne participent pas au réglage de la production, cela doit être changé à cause de l'augmentation continue de leurs taux de pénétration dans les réseaux électriques. En raison de la source primaire de ces systèmes de production d'énergie (le vent), qui est très aléatoire et imprévisible, une éolienne seule ne peut pas faire le réglage de la production. Donc, on a besoin d'un système de stockage jouant le rôle de tampon entre la source et le consommateur. Le système de stockage doit être assez dynamique afin qu'il soit capable d'agir en temps réel, en fonction des fluctuations de la puissance générée et consommée. Le système inertiel de stockage d'énergie (SISE) est approprié pour ce type d'application en raison de ces caractéristiques: bonne dynamique, bon rendement, durée de vie similaire à l'éolienne, écologique, etc. Donc, le premier but de ce travail a été de faire une étude approfondie sur les SISEs. L'étude a été faite du point de vue de l'association du SISE avec un générateur éolien. Le deuxième objectif de la thèse a été d'étudier et de proposer des méthodes de contrôle et supervision d'un SISE associé à un générateur éolien à vitesse variable. Le but est de contrôler le transit de puissance entre le générateur et le réseau ou la charge isolée, afin de rendre les systèmes éoliens capables à fournir des services systèmes et de fonctionner en îloté. Enfin, le troisième objectif a été de réaliser une plateforme expérimentale permettant l'implantation pratique et l'expérimentation des principes développés en théorie.
12

Contribution à la commande et l'observation des actionneurs électropneumatiques : de l'intérêt de la transformée A-T

Abry, Frédéric 02 December 2013 (has links) (PDF)
La commande des actionneurs électropneumatiques a été un sujet largement traité au cours des dernières décennies. Le caractère fortement non-linéaire de son comportement en a fait un cas d'étude particulièrement pertinent dans le cadre d'une démarche d'application de la théorie de la commande des systèmes non-linéaires. L'utilisation de ces techniques a été comparée aux approches linéaires traditionnelles et généralement jugée largement supérieure notamment en termes de précision ou de temps de réponse. Dans ce manuscrit nous abordons très spécifiquement l'aspect multivariable du système et introduisons la transformée A-T, similaire à la transformée de Park appliquée classiquement aux systèmes électriques, afin de donner une forme strict feedback à son modèle d'état, de clarifier les phénomènes physiques mis en jeu lors de sa commande et de distinguer les deux degrés de liberté du système. Cette transformée permet en outre une comparaison directe avec les moteurs électriques décrits dans le repère de Park. Ce parallèle rend notamment possible la solution du problème délicat de l'observation de la position à vitesse nulle en transférant des méthodologies déjà validées sur des systèmes électriques. L'exploitation des deux degrés de liberté est illustrée par la synthèse de lois de commande combinant le suivi d'une trajectoire de position du piston au respect d'un second critère variable (réglage de la pressurisation moyenne, optimisation de la consommation instantanée). L'utilisation d'un actionneur électropneumatique asservi comme actionneur à compliance variable est étudiée. Une loi de commande basée sur la transformée A-T est proposée pour contrôler simultanément la position et la raideur pneumatique de l'actionneur. Une méthodologie de réglage des gains de commande est proposée pour définir l'impédance en boucle fermée du système. L'influence de la raideur pneumatique sur la raideur en boucle fermée est étudiée. L'utilisation d'une source d'énergie alternative (de l'hélium sous pression) est également pour la première fois mise en œuvre. L'influence du changement de gaz sur le dimensionnement de l'actionneur électropneumatique est étudiée et une méthodologie permettant d'utiliser les lois de commande prévues pour de l'air est proposée. L'ensemble des propositions faites dans ce manuscrit est testée et validée sur un banc d'essais à la structure inédite. Ce dernier allie deux actionneurs, l'un électropneumatique (l'actionneur étudié) et l'autre, un moteur plat électrique (l'actionneur de charge). L'utilisation de celui-ci permet la génération d'efforts perturbateurs dans une large bande passante ainsi que la modification en temps réel des paramètres mécaniques dynamiques de la charge.
13

Contribution à la commande et l'observation des actionneurs électropneumatiques : de l'intérêt de la transformée A-T / Contribution to the control and the observation of the electropneumatic actuators : introducing the A-T transformation

Abry, Frédéric 02 December 2013 (has links)
La commande des actionneurs électropneumatiques a été un sujet largement traité au cours des dernières décennies. Le caractère fortement non-linéaire de son comportement en a fait un cas d'étude particulièrement pertinent dans le cadre d'une démarche d'application de la théorie de la commande des systèmes non-linéaires. L'utilisation de ces techniques a été comparée aux approches linéaires traditionnelles et généralement jugée largement supérieure notamment en termes de précision ou de temps de réponse. Dans ce manuscrit nous abordons très spécifiquement l'aspect multivariable du système et introduisons la transformée A-T, similaire à la transformée de Park appliquée classiquement aux systèmes électriques, afin de donner une forme strict feedback à son modèle d'état, de clarifier les phénomènes physiques mis en jeu lors de sa commande et de distinguer les deux degrés de liberté du système. Cette transformée permet en outre une comparaison directe avec les moteurs électriques décrits dans le repère de Park. Ce parallèle rend notamment possible la solution du problème délicat de l'observation de la position à vitesse nulle en transférant des méthodologies déjà validées sur des systèmes électriques. L'exploitation des deux degrés de liberté est illustrée par la synthèse de lois de commande combinant le suivi d'une trajectoire de position du piston au respect d'un second critère variable (réglage de la pressurisation moyenne, optimisation de la consommation instantanée). L'utilisation d'un actionneur électropneumatique asservi comme actionneur à compliance variable est étudiée. Une loi de commande basée sur la transformée A-T est proposée pour contrôler simultanément la position et la raideur pneumatique de l'actionneur. Une méthodologie de réglage des gains de commande est proposée pour définir l'impédance en boucle fermée du système. L'influence de la raideur pneumatique sur la raideur en boucle fermée est étudiée. L'utilisation d'une source d'énergie alternative (de l'hélium sous pression) est également pour la première fois mise en œuvre. L'influence du changement de gaz sur le dimensionnement de l'actionneur électropneumatique est étudiée et une méthodologie permettant d'utiliser les lois de commande prévues pour de l'air est proposée. L'ensemble des propositions faites dans ce manuscrit est testée et validée sur un banc d'essais à la structure inédite. Ce dernier allie deux actionneurs, l'un électropneumatique (l'actionneur étudié) et l'autre, un moteur plat électrique (l'actionneur de charge). L'utilisation de celui-ci permet la génération d'efforts perturbateurs dans une large bande passante ainsi que la modification en temps réel des paramètres mécaniques dynamiques de la charge. / Control of electropneumatic actuator is a subject which has been thoroughly dealt with in the past decades. The strongly non-linear behavior of those systems made them a particularly relevant case study for applications of the non linear control theory. The use of those techniques has been compared to the traditional linear approaches and is generally considered as more efficient in terms of precision and response time. In this work, we specifically deal with the multivariable character of this actuator and we introduce the A-T transformation, similar to the Park Transformation used for electrical systems study, in order to give a strict feedback form to its state model, clarify the physical phenomena occurring during its control and distinguish the system's two degrees of freedom. This transformation allows a comparison with electrical motors described in the Park's frame. This parallel allows to solution the complex problem of zero speed observation of the piston's position by transferring the methodologies which have been previously used on electrical systems. The utilization of the two degrees of freedom is illustrated by the synthesis of control law which combines the piston position trajectory tracking with the respect of a given criterion (which can be the pressurization level or the instantaneous gas consummation optimization). The use of an electropneumatic actuator as a variable stiffness actuator (VSA) is studied. A control law base on the A-T transform is proposed in order to simultaneously control the position and the pneumatic stiffness of the actuator. A control gains tuning strategy is proposed to allow the system closed loop impedance tuning. The influence of the pneumatic stiffness over the closed loop stiffness is studied. An alternative energy source (pressurized helium) is also used for the first time. The influence of the change of gas over the actuator sizing is studied and a methodology allowing using control laws designed for air applications is proposed. Every proposition are tested and validated using an innovative test bench with a unique structure. The latter combines two actuators. One is an electropneumatic actuator (the one studied) and the other one is a linear motor (used as the load actuator). The use of the latter allows disturbance generation in a wide bandwidth and the real-time tuning of the load dynamic characteristics. Finally, the tools developed in this PHD are used in order to validate the implementation of an electropneumatic solution to the thrust vector control problem of a nano scale space launcher. Data provided by the CNES (the French National Space Agency) are used to de ne specific requirements and the flight conditions are reproduced on the test bench to assess the solution quality.
14

Comportement thermodynamique de réservoirs d’ergols cryogéniques : étude expérimentale et théorique d’un système de contrôle pour des missions spatiales de longue durée / Characterisation of the atomization regimes of cryogenic propellants used in the thermodynamic control of tanks

Demeure, Lauriane 25 October 2013 (has links)
La thèse porte sur l'étude d'un système de contrôle de la pression au sein de réservoirs d’ergols cryogéniques (dihydrogène ou dioxygène) dans le cadre de missions spatiales de longue durée. Ce système de contrôle doit permettre d’éviter la perte excessive d’ergols associée à un contrôle basique de la pression consistant en l’évacuation directe d’une fraction du fluide. Le système alternatif étudié, dit de contrôle thermodynamique, repose sur la réinjection d’un spray sous-refroidi permettant d’abaisser température et pression dans un réservoir soumis à une chauffe (en pratique, le rayonnement solaire). Nous avons analysé les performances de ce système en développant en parallèle un banc d'essai adapté aux conditions du laboratoire, et un modèle théorique de type 0D, à base de bilans globaux, de l’effet du spray sous-refroidi sur les caractéristiques thermodynamiques de l’enceinte. La confrontation des mesures et des calculs a permis de valider l’outil de modélisation théorique. Les caractéristiques du système réel (ensemble des circuits d'injection et de refroidissement) ont ensuite été introduites dans le modèle théorique afin de quantifier de façon réaliste les gains offerts par le système de contrôle thermodynamique, i.e. en prenant en compte la pénalité en masse associée à ces circuits. Des solutions optimales de contrôle de la pression au sein de réservoirs d’ergols cryogéniques lors de missions spatiales de longue durée ont pu alors être proposées. / This PHD thesis deals with the study of a pressure control system inside a cryogenic propellant tank for long duration space missions. This system must be able to reduce propellant losses induced by direct venting, which is the simplest pressure control system. The alternative system which has been studied, called Thermodynamic Vent System (TVS), is based on reinjecting subcooled spray to make the pressure and temperature decrease in a heated tank. The system performance has been analysed developing simultaneously an experimental setup, adapted to laboratory environment, and a theoretical 0D-modelling of subcooled spray impact on tank's thermodynamic characteristics. Facing experimental and theoretical results has permitted to validate the 0D-modelling tool. Inputing the real system characteristics in theoretical modelling has enabled to assess the effective gains of thermodynamic vent system. Finally, optimal solutions to control pressure inside a cryogenic propellant tank for long duration space missions have been proposed.
15

Contribution au dimensionnement et à l'optimisation des systèmes hybrides éoliens-photovoltaïques avec batteries pour l'habitat résidentiel autonome / Contribution to the sizing and to the optimization of the wind-photovoltaic hybrid systems with batteries for the autonomous residential housing environment

Abbes, Dhaker 20 June 2012 (has links)
Cette thèse est une contribution à l'étude des systèmes hybrides éoliens-photovoltaïques avec batteries sur plusieurs aspects : évaluation des sources, modélisation, simulation, optimisation du dimensionnement et enfin commande et supervision. Ainsi, dans un premier temps, une étude d'impact sur l'évaluation du potentiel en énergies renouvelables sur un site donné en prenant en compte la consommation dans un habitat résidentiel (période et méthode d'acquisition des données, techniques d'évaluation, ...) est présentée. Puis, les modèles énergétiques des différents composants du système ainsi que les aspects économiques et écologiques sont définis. L'ensemble est représenté à l'aide du logiciel Matlab/Simulink. Ensuite, une méthodologie d'optimisation du dimensionnement du système multi-sources est développée et comparée à plusieurs approches, allant d'une optimisation mono-objective à une multi-objective et évaluant le coût économique et écologique de chacune de ces solutions. Une solution « pratique » est retenue pour les composants PV, éolien et batteries du système final afin d'en évaluer la viabilité énergétique, économique et écologique. Les résultats montrent un impact environnemental faible et un coût raisonnable du point de vue économique ainsi qu'une satisfaction de la charge dans les limites tolérées par l'usager. La méthode développée de dimensionnement est comparée à un outil commercial existant. Enfin, un banc expérimental PV-éolien avec batteries est mis en oeuvre avec une nouvelle technique de supervision basée sur le contrôle des courants et l'estimation de l'état de charge des batteries. / This thesis is a contribution to the study of photovoltaic-wind-battery hybrid systems for several aspects: source evaluation, modeling and simulation, design optimization and finally control and supervision. Thus, an impact study on the evaluation of renewable energy potential at a given site taking into account consumption in residential housing (period and method of data acquisition, evaluation techniques...) is presented. In addition, all the components of the system are modeled and economic and ecological aspects are defined in order to make an overall assessment of various system configurations. All models are represented using Matlab/Simulink tool. Then, a methodology for single and multi-objective design optimization of a multi-source system is developed to minimize system Life Cycle Cost (LCC), Embodied Energy (EE) and Loss of Power Supply Probability (LPSP). A "practice solution" is thus retained and evaluated. Results show a low environmental impact and a reasonable economic cost as well as a satisfaction of the load within the limits tolerated by the user. Besides, a very convincing comparison of the developed sizing method to an existing commercial tool is presented. At the end, an experimental PV-wind-battery tested is developed in laboratory to ensure a quasi-realistic emulation of hybrid system behavior for different configurations. Accordingly, a new supervision strategy based on currents control and battery state of charge estimation is successfully validated.

Page generated in 0.0698 seconds