Spelling suggestions: "subject:"consentimento cardíaca""
91 |
Relações entre eficiência alimentar e características de carcaça, qualidade de carne, batimentos cardíacos e consumo de oxigênio em bovinos / Relationships between feed efficiency and carcass characteristics, meat quality, heart rate and oxygen consumption in beef cattleAmália Saturnino Chaves 04 October 2013 (has links)
O interesse quanto ao uso de índices de eficiência alimentar na seleção de bovinos é crescente, pela sua associação com o custo de produção e impacto ambiental. O objetivo deste trabalho foi avaliar dois índices de eficiência, o consumo alimentar residual (CAR) e consumo e ganho residual (CGR) e suas relações com desempenho, características de carcaça, qualidade de carne, batimentos cardíacos e consumo de oxigênio em bovinos Nelore. Foram avaliados 84 animais para desempenho, peso de carcaça, rendimento, área de olho de lombo, espessura de gordura subcutânea, peso de vísceras e gordura interna. Foi avaliada a qualidade da carne de amostras não maturadas e maturadas (pH, força de cisalhamento, cor, perdas por cocção, capacidade de retenção de água, índice de fragmentação miofibrilar e gordura intramuscular). Para estimar a produção de calor (PC) pela metodologia do Pulso de O2 (O2P), 39 animais foram monitorados para frequência cardíaca, que foi calibrada para consumo de O2 em 18 deles. A PC foi estimada multiplicando-se o total de batimentos cardíacos diários pelo volume de O2/batimento e pela constante 4,89 kcal/LO2. Foram estudados os coeficientes de inclinação das retas entre CAR e CGR e as variáveis estudadas. O CAR não foi associado com o peso vivo e ganho de peso (P>0,05), porém animais eficientes consumiram 16,1% menos alimento (P<0,0001). Animais eficientes para CGR apresentaram consumo 11,7% menor e ganharam mais peso (P<0,01). O CGR não foi associado ao peso vivo metabólico médio (P>0,05), contudo foi associado ao peso vivo final (P=0,06). A PC estimada pela diferença entre energia retida e consumo de energia metabolizável foi maior nos animais ineficientes (P<0,0001), porém não foi diferente quando estimada pela metodologia do O2P (P>0,05). A frequência cardíaca (FC) e consumo de O2 não foram associados ao CAR e CGR (P>0,05), contudo a FC foi menor nos animais eficientes durante a calibração do O2 (P<0,05). Ambos os índices foram associados com mudanças na composição corporal; animais eficientes para CAR apresentaram menor teor de gordura subcutânea avaliada por ultrassom (P=0,08), e os eficientes para CGR apresentaram maior AOL (P<0,05). As características de qualidade da carne não foram associadas ao CAR, mas animais eficientes para CGR apresentaram intensidade da cor vermelha na carne menor e na gordura maior (P<0,05). Animais eficientes quanto ao CAR apresentaram menor peso de fígado e de gordura interna (P<0,05) sendo este efeito não observado para CGR. Os animais eficientes em ambos, CAR e CGR, apresentaram menor custo de produção resultando em aumento no lucro (P<0,01). O lucro foi fortemente associado à conversão alimentar, CGR e ganho de peso (r=-0,812; 0,72 e 0,61; P<0,0001) enquanto sua associação com CAR foi menor (r=-0,46; P<0,0001). As correlações fenotípicas sugerem que seleção de animais eficientes para CAR ou CGR pode reduzir custos na produção de bovinos de corte, com alteração na coloração da carne. O lucro tem maior correlação com o CGR que com CAR. Porém o CGR tem a possível desvantagem de ser fenotipicamente associado ao maior peso final o que pode indicar uma correlação genética para peso adulto. / There is growing interest in the use of feed efficiency in beef cattle, due to its relationship to production costs and environmental impact. Identification of variation in energy losses can explain differences in efficiency. The objective of this study was to evaluate measures of feed efficiency (residual feed intake - RFI and residual intake and gain _ RIG) and their relationships with performance, carcass characteristics, meat quality, heart rate and oxygen use in Nellore bulls. A group of 84 animals were evaluated for performance, carcass characteristics (weight, yield, loin eye area, fat thickness, weight of visceral and internal fat) and meat quality in fresh and aged meat samples (pH, shear force, cooking loss, water retention capacity, myofibrilar fragmentation index and intramuscular fat). To estimate heat production (HP) by O2 pulse methodology (O2P), 39 animals were monitored for heart rate (HR). A subgroup of 18 animals which was calibrated for O2 consumption determined over in 18 of them. HP was estimated multiplying daily heart beats by O2 volume per beat, assuming 4.89 kcal/LO2 as constant. The slope coefficient for each variable against RFI and RIG was studied. There was no association of RFI with weight (P>0.05) and weight gain (P>0.05), but efficient animals consumed 16.1% less feed (P<0.0001). Efficient animals for RIG consumed 11.7% less food (P<0.0001), but gained more weight than inefficient animals (P<0.01). There was no association between RIG and average metabolic weight (P>0.05), however RIG was related to final weight (P=0.06). HP estimated by the difference between retained energy and metabolic energy intake was higher for inefficient animals (P<0.001), for both RFI and RIG. However there was no effect on HP estimated by the O2P methodology (P>0.05). Heart rate (HR) and O2 consumption were not associated with RFI and RIG (P>0.05), but HR was lower in efficient animals during O2 calibration (P<0.05). There was a positive association of efficiency with a leaner gain composition, where efficient animals for RFI had of lower ultrasound subcutaneous fat (P=0.08), while efficient animals for RIG had higher loin eye area (P<0.05). There was no effect on meat quality parameters for RFI but in efficient animals for RIG, there was an effect on meat and fat color (P<0.05) compared to inefficient animals. Internal fat and liver weights were decreased in efficient animals according to RFI (P<0.05), but unchanged according to RIG (P>0.05). Efficient animals for RFI and RIG had lower cost of production resulting in increased profit (P<0.01). Profit was strongly associated with feed intake, RIG and weight gain (r =-0.81, 0.72 and 0.61, P<0.0001), whereas its association with RFI was lower (r =-0.46, P<0.0001). Efficient animals for RFI and RIG are more profitable with small decreases in fat and small increases in muscle content. Profit is better related to RIG than RFI. However, RIG had the disadvantage of increasing final test weight which could be genetically associated with mature weight.
|
92 |
Análise dos intervalos (R-R) entre monitor WCS Pulse e eletrocardiograma portátil porta PAK/90 / Analysis of the RR interval monitors WCS Pulse and comparison with porta Pak/90 electrocardiogramBuck, Fabiano 24 June 2016 (has links)
Intervalos dos batimentos (R-R) vêm sendo considerado pela literatura, como um dos mais promissores meios de análise do sistema autônomo. Porém, diversos monitores e seus métodos, necessitam de validação através da análise dos parâmetros de VFC. O objetivo deste estudo foi validar um instrumento portátil, específico para mensuração dos intervalos dos batimentos (R-R) da marca WCS Pulse. Para a proposta deste estudo, 30 indivíduos do sexo masculino praticantes de Jiu-Jitsu, foram monitorados através de ECG e monitor WCS Pulse. Os parâmetros de VFC: intervalos (R-R), LF, HF e LF/HF foram coletados em pré- exercício, 24 e 48 horas após exercício. Conforme os resultados observados, os instrumentos ECG e WCS Pulse apresentam forte correlação e forte coeficiente de correlação intra-Classe, nos parâmetros de VFC (LF, HF e LF/HF). Por outro lado, quanto aos valores de Student t aplicados nos intervalos (R-R), foi observado diferença significativa entre os instrumentos (p<0.05) em todos os momentos da pesquisa. Através deste estudo, pode-se considerar que o monitor dos intervalos dos batimentos (R-R) da marca WCS Pulse é uma ferramenta de biomarcador (não invasivo) eficaz. Nesta esteira, o equipamento de monitoração dos intervalos (R-R) WCS Pulse, demonstrou um grau de concordância para a utilização em centros de treinamentos esportivos e ciências da saúde; porém, os parâmetros de resolução de amostragem do instrumento WCS Pulse, deve ser mais bem observado quando for comparado com instrumentos existentes no mercado e ou eletrocardiogramas. / The RR interval has been considered in the literature, the most promising analysis autonomous system. However, several monitors and validation methods is necessary through of the HRV parameters analysis. The aim of this study was, validate portable specific instrument to measurement RR interval WCS Pulse. For the proposal of this study, 30 male practitioners of BJJ were monitored through ECG and monitor Pulse WCS in different ways. The parameters of HRV: RR interval, LF, HF and LF / HF were collected in pre-exercise, 24 and 48 hours after exercise. Results: ECG instruments and WCS Pulse demonstrated strong correlation (r), and strong values to coefficient of intra-class in HRV parameters (LF, HF and LF / HF). In the other hand, the Student t values applied on the RR interval, was observed significant difference between the instruments in all moments of the research (p <0.05). Through this study, we consider that monitor RR interval WCS Pulse is effective biomarker tool (noninvasive). Thus, the equipment monitoring of RR intervals WCS Pulse, showed highs degree of agreements for use in sports training centers and Health Sciences; However, the instrument sampling resolution parameters, WCS Pulse should be more observed when compared to existing instruments in the market and electrocardiogram.
|
93 |
Correlações entre os valores de lactato mínimo e potência anaeróbia com a potência crítica e a capacidade de trabalho anaeróbio obtidas por método invasivo e não invasivosAfonso, Marcia [UNESP] 17 May 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:52Z (GMT). No. of bitstreams: 0
Previous issue date: 2004-05-17Bitstream added on 2014-06-13T19:49:12Z : No. of bitstreams: 1
afonso_m_me_rcla.pdf: 222236 bytes, checksum: 1a0edd0d0141d788c0b3436c47d1f119 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O limiar anaeróbio (LAN) tem sido muito utilizado como preditor da capacidade aeróbia na avaliação e prescrição do treinamento. Dentre os protocolos de determinação do LAN, o método do lactato mínimo (LM) parece ser um dos mais precisos, determinando de certa forma, individualmente os valores do LAN. Um outro modelo utilizado na avaliação do parâmetro aeróbio é o método não invasivo de determinação de potência crítica (PC), sendo que esse modelo possibilita também a quantificação das reservas anaeróbias intramusculares (CTA). Vários autores propõem determinações de PC por diferentes protocolos, dentre eles, os propostos por JENKINS & QUIGLEY em 1991 (PCJQ) e CHASSAIN em 1986 (PCCH) especialmente, são muito diferentes, no aspecto metodológico e repercutiram bastante no meio científico. O objetivo do presente estudo foi de comparar métodos invasivos e não invasivos de avaliação aeróbia e anaeróbia em atletas ciclistas, identificando a relação existente entre o LM e a PC (determinada por dois métodos diferentes) e, a relação dos parâmetros anaeróbios, através da potência média e da potência pico com a CTA. Foram voluntários desse estudo 9 ciclistas treinados do sexo masculino (24,11 1,62 anos; 67,28 4,37 kg e 175,78 5,89 cm) com experiência na modalidade. Os atletas foram submetidos a três protocolos experimentais: 1) Teste de LM, com teste de Wingate para induzir a acidose e posterior exercício progressivo; 2) Teste de PCJQ com quatro sessões de cargas exaustivas randômicas; 3) Teste de PCCH a partir da variação da freqüência cardíaca e do lactato através de dois esforços de 180 segundos com intervalo de pausa de 90 segundos entre os esforços, com intensidade de 85, 95, 105 e 115% do LM. Foram encontradas diferenças significativas entre as intensidades de LM (219,73 4,43 W), PCJQ nos modelos Pot- 1/tlim... . / The anaerobic threshold (AT) has been used as a good predictor of the aerobic capacity for physical evaluation and training prescription. Among the protocols of AT determination, the lactate minimal test (LMT) seems to be one of the most accurate for obtain individually the AT values. Another model used in the aerobic evaluation is the non-invasive method for determination of the critical power (CP), and this model also makes possible the quantification of the intramuscular anaerobic stores, which represents the anaerobic work capacity (AWC). Several authors proposed determinations of CP on different protocols, as those propored by, Jenkins & Quigley (1991 - CPJQ) and Chassain (1986 - CPCH), that in spite of the very different methodological aspects they are a reference in the scientific way. The purpose of the present study was to compare invasive and non-invasive protocols to evaluate the aerobic and anaerobic fitness (by two different methods) in cyclists. Also, the relationship of the mean and peak power obtained during an Wingate test to AWC identified by different methods was investigate. Nine male trained cyclists volunteered to the study (24.11 l 1.62 years; 67.28 l 4.37 kg and 175.78 l 5.89 cm). The athletes were submitted to three experimental protocols: 1) LMT, with initial lactic acidosis induced thought a Wingate test and a subsequent incremental exercise test; 2) test of PCJQ with four sessions of random exhaustive loads; 3) test of PCCH based on the variation of the heart rate and lactate along two bouts of efforts of 180 seconds with pause interval of 90 seconds between them, with intensity of 85, 95, 105 and 115% of LMT. Our results showed significant differences among the intensities of LMT (219.73 l 4.43 W), PCJQ in the models P-1/tlim (301.47 l 10.46 W) and Wlim - tlim (295.22 l 10.14 W) and, in PCCH for the methods of lactate variation (201.53 l 4.44 W) and... (Complete abstract, click electronic address below).
|
94 |
Correlações entre os valores de lactato mínimo e potência anaeróbia com a potência crítica e a capacidade de trabalho anaeróbio obtidas por método invasivo e não invasivos /Afonso, Marcia. January 2004 (has links)
Orientador: Claudio Alexandre Gobatto / Banca: Eduardo Kokubun / Banca: Herbert Gustavo Simões / Resumo: O limiar anaeróbio (LAN) tem sido muito utilizado como preditor da capacidade aeróbia na avaliação e prescrição do treinamento. Dentre os protocolos de determinação do LAN, o método do lactato mínimo (LM) parece ser um dos mais precisos, determinando de certa forma, individualmente os valores do LAN. Um outro modelo utilizado na avaliação do parâmetro aeróbio é o método não invasivo de determinação de potência crítica (PC), sendo que esse modelo possibilita também a quantificação das reservas anaeróbias intramusculares (CTA). Vários autores propõem determinações de PC por diferentes protocolos, dentre eles, os propostos por JENKINS & QUIGLEY em 1991 (PCJQ) e CHASSAIN em 1986 (PCCH) especialmente, são muito diferentes, no aspecto metodológico e repercutiram bastante no meio científico. O objetivo do presente estudo foi de comparar métodos invasivos e não invasivos de avaliação aeróbia e anaeróbia em atletas ciclistas, identificando a relação existente entre o LM e a PC (determinada por dois métodos diferentes) e, a relação dos parâmetros anaeróbios, através da potência média e da potência pico com a CTA. Foram voluntários desse estudo 9 ciclistas treinados do sexo masculino (24,11 1,62 anos; 67,28 4,37 kg e 175,78 5,89 cm) com experiência na modalidade. Os atletas foram submetidos a três protocolos experimentais: 1) Teste de LM, com teste de Wingate para induzir a acidose e posterior exercício progressivo; 2) Teste de PCJQ com quatro sessões de cargas exaustivas randômicas; 3) Teste de PCCH a partir da variação da freqüência cardíaca e do lactato através de dois esforços de 180 segundos com intervalo de pausa de 90 segundos entre os esforços, com intensidade de 85, 95, 105 e 115% do LM. Foram encontradas diferenças significativas entre as intensidades de LM (219,73 4,43 W), PCJQ nos modelos Pot- 1/tlim... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The anaerobic threshold (AT) has been used as a good predictor of the aerobic capacity for physical evaluation and training prescription. Among the protocols of AT determination, the lactate minimal test (LMT) seems to be one of the most accurate for obtain individually the AT values. Another model used in the aerobic evaluation is the non-invasive method for determination of the critical power (CP), and this model also makes possible the quantification of the intramuscular anaerobic stores, which represents the anaerobic work capacity (AWC). Several authors proposed determinations of CP on different protocols, as those propored by, Jenkins & Quigley (1991 - CPJQ) and Chassain (1986 - CPCH), that in spite of the very different methodological aspects they are a reference in the scientific way. The purpose of the present study was to compare invasive and non-invasive protocols to evaluate the aerobic and anaerobic fitness (by two different methods) in cyclists. Also, the relationship of the mean and peak power obtained during an Wingate test to AWC identified by different methods was investigate. Nine male trained cyclists volunteered to the study (24.11 l 1.62 years; 67.28 l 4.37 kg and 175.78 l 5.89 cm). The athletes were submitted to three experimental protocols: 1) LMT, with initial lactic acidosis induced thought a Wingate test and a subsequent incremental exercise test; 2) test of PCJQ with four sessions of random exhaustive loads; 3) test of PCCH based on the variation of the heart rate and lactate along two bouts of efforts of 180 seconds with pause interval of 90 seconds between them, with intensity of 85, 95, 105 and 115% of LMT. Our results showed significant differences among the intensities of LMT (219.73 l 4.43 W), PCJQ in the models P-1/tlim (301.47 l 10.46 W) and Wlim - tlim (295.22 l 10.14 W) and, in PCCH for the methods of lactate variation (201.53 l 4.44 W) and... (Complete abstract, click electronic address below). / Mestre
|
95 |
Monitoramento da frequência cardíaca via método de magnificação de vídeo e Euleriana em tempo realSimioni, Maicon Cezar 18 August 2015 (has links)
O monitoramento de sinais vitais em pacientes tem o intuito de obter rapidamente dados relevantes para decisões médicas. No entanto, tal mensuração é pouco eficiente, difícil, quando não impossível, em determinados casos, como por exemplo em pacientes vítimas de queimaduras, em função da impossibilidade de colocar o eletrodo diretamente na pele, ou em recém-nascidos, devido à fragilidade da pele. Este estudo trata do desenvolvimento de um sistema para aquisição contínua de sinais fotopletismográficos para a telemetria da frequência cardíaca em tempo real, em uma plataforma de baixo custo, utilizando a biblioteca OpenCV e o método desenvolvido pelo MIT chamado de Magnificação de Vídeo Euleriana, que revela variações que são imperceptíveis a olho nu. Para desenvolver o sistema foi utilizada a plataforma de hardware Raspberry Pi Versão B com processador ARM11 de 700MHz e 512MB de memória RAM. Os dados da frequência cardíaca coletados dos experimentos foram comparados com os dados coletados por um oxímetro de dedo More Fitness modelo MF-425. Esse foi escolhido por utilizar o mesmo princípio "Fotopletismografia"para efetuar a medição. Após a coleta de dados foi estimado o intervalo de confiança para aferir a precisão do sistema, que correspondeu a 96,5% em relação ao oxímetro utilizado. Ficou evidente que o meio utilizado para medir a frequência cardíaca via método de magnificação de vídeo Euleriana em tempo real é uma tecnologia de baixo custo (aproximadamente R$300,00) quando comparado aos monitores multiparamétricos utilizados para o monitoramento de pacientes críticos, cujo custo varia entre R$ 8.000,00 e R$ 34.000,00. Sendo assim, também contribui com a redução de custos no tratamento ao doente que necessita de monitorização constante, possibilitando que, com a economia gerada pela aquisição e implantação desta tecnologia, viabilize um maior investimento em outras áreas dos hospitais. / Monitoring vital signs in patients is used to obtain relevant data for medical decisions in a fast way. However, this measurement is both inefficient and difficult, if not impossible in certain cases, such as in burnt victims, due to the impossibility of placing the electrodes directly on the skin or in infants, because of the fragility of skin. This study aims to develop of a system for continuous acquisition of photopletismografics (PPG) signals for the telemetry of heart rate in real time in a low cost platform using the OpenCV library and the method developed by MIT called the Eulerian Video Magnification, amplifying variations that are imperceptible to the naked eye. To develop the system were used the hardware platform Raspberry Pi version B with ARM11 700MHz processor and 512MB RAM. The heart rate data collected from the experi- ments were compared with data collected by a finger oximeter model More Fitness MF-425 it was chosen, by using the same working principle "PPG"to effect the measurement. After data collection was estimated the confidence interval to measure system accuracy, which corresponded to 96,5% compared to the oximeter used. It became clear that the developed system used to measure heart rate via magnification method of Eulerian live video is a low-cost technology (approximately R$ 300.00) compared to the multiparameter monitors used for monitoring critically patients, ranging in cost from R$ 8,000.00 to R$ 34,000.00. So also, it contributes to cost reduction in the treatment to the patient in need of constant monitoring, enabling with the savings generated by the acquisition and deployment of this technology makes possible greater investment in other areas of hospitals. / 5000
|
96 |
Monitoramento da frequência cardíaca via método de magnificação de vídeo e Euleriana em tempo realSimioni, Maicon Cezar 18 August 2015 (has links)
O monitoramento de sinais vitais em pacientes tem o intuito de obter rapidamente dados relevantes para decisões médicas. No entanto, tal mensuração é pouco eficiente, difícil, quando não impossível, em determinados casos, como por exemplo em pacientes vítimas de queimaduras, em função da impossibilidade de colocar o eletrodo diretamente na pele, ou em recém-nascidos, devido à fragilidade da pele. Este estudo trata do desenvolvimento de um sistema para aquisição contínua de sinais fotopletismográficos para a telemetria da frequência cardíaca em tempo real, em uma plataforma de baixo custo, utilizando a biblioteca OpenCV e o método desenvolvido pelo MIT chamado de Magnificação de Vídeo Euleriana, que revela variações que são imperceptíveis a olho nu. Para desenvolver o sistema foi utilizada a plataforma de hardware Raspberry Pi Versão B com processador ARM11 de 700MHz e 512MB de memória RAM. Os dados da frequência cardíaca coletados dos experimentos foram comparados com os dados coletados por um oxímetro de dedo More Fitness modelo MF-425. Esse foi escolhido por utilizar o mesmo princípio "Fotopletismografia"para efetuar a medição. Após a coleta de dados foi estimado o intervalo de confiança para aferir a precisão do sistema, que correspondeu a 96,5% em relação ao oxímetro utilizado. Ficou evidente que o meio utilizado para medir a frequência cardíaca via método de magnificação de vídeo Euleriana em tempo real é uma tecnologia de baixo custo (aproximadamente R$300,00) quando comparado aos monitores multiparamétricos utilizados para o monitoramento de pacientes críticos, cujo custo varia entre R$ 8.000,00 e R$ 34.000,00. Sendo assim, também contribui com a redução de custos no tratamento ao doente que necessita de monitorização constante, possibilitando que, com a economia gerada pela aquisição e implantação desta tecnologia, viabilize um maior investimento em outras áreas dos hospitais. / Monitoring vital signs in patients is used to obtain relevant data for medical decisions in a fast way. However, this measurement is both inefficient and difficult, if not impossible in certain cases, such as in burnt victims, due to the impossibility of placing the electrodes directly on the skin or in infants, because of the fragility of skin. This study aims to develop of a system for continuous acquisition of photopletismografics (PPG) signals for the telemetry of heart rate in real time in a low cost platform using the OpenCV library and the method developed by MIT called the Eulerian Video Magnification, amplifying variations that are imperceptible to the naked eye. To develop the system were used the hardware platform Raspberry Pi version B with ARM11 700MHz processor and 512MB RAM. The heart rate data collected from the experi- ments were compared with data collected by a finger oximeter model More Fitness MF-425 it was chosen, by using the same working principle "PPG"to effect the measurement. After data collection was estimated the confidence interval to measure system accuracy, which corresponded to 96,5% compared to the oximeter used. It became clear that the developed system used to measure heart rate via magnification method of Eulerian live video is a low-cost technology (approximately R$ 300.00) compared to the multiparameter monitors used for monitoring critically patients, ranging in cost from R$ 8,000.00 to R$ 34,000.00. So also, it contributes to cost reduction in the treatment to the patient in need of constant monitoring, enabling with the savings generated by the acquisition and deployment of this technology makes possible greater investment in other areas of hospitals. / 5000
|
Page generated in 0.1181 seconds