• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 187
  • 133
  • 31
  • 11
  • 8
  • 8
  • 5
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 484
  • 148
  • 75
  • 73
  • 47
  • 45
  • 44
  • 43
  • 43
  • 42
  • 40
  • 39
  • 37
  • 34
  • 33
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Biokompatibilita implantabilních materiálů se zaměřením na titanové dentální implantáty / Biocompatibility of Implantable Materials Focused on Titanium Dental Implants

Moztarzadeh, Amin January 2017 (has links)
This dissertation thesis deals with the evaluation of biocompatibility and osseointegration of nanostructured titanium materials used for dental implants. Bulk material topography and surface modification of titanium are currently of intense research mainly due to the significant impact on biocompatibility and improvement of osseointegration of dental implants. In the theoretical part are described types of titanium material and different methods of its surface modification. In vitro and in vivo biocompatibility and osseointegration tests are described as well. The experimental work consists of two parts of experiments. In the first experiment, we examined how grain size of nanostructured titanium material influences the behaviour of fibroblastic as well as osteoblastic cells growth on its surface. The experimentally obtained data were statistically analysed and discussed. Grain size was proven to be an important factor that influenced not only the strength of material but also its interactions with cells. The second experiment describes current methods used in the experimental evaluation of osseointegration of dental implants. The results of histological staining methods are illustrated and compared. A standardized and reproducible technique for stereological quantification of bone-implant contact...
322

Etude de la biocompatibilité de biomatériaux, de la récupération fonctionnelle et de la stratégie neurale dans le cadre de l'arthroplastie totale de genou chez le rat / Study of biomaterials' biocompatibility, functional recovery and neural strategy in the context of rat total knee arthroplasty

Lecocq, Mathieu 12 July 2017 (has links)
L'arthroplastie totale du genou (ATG) est le traitement de référence de l’ostéoarthrose sévère du genou. Cette procédure nécessite une chirurgie lourde qui induit de nombreux déficits qui persistent pendant plusieurs années. Par ailleurs, les prothèses ont une durée de vie limitée de par les contraintes chimiques et mécaniques se produisant dans l'environnement biologique. Nous avons testé en condition in vivo la biocompatibilité de quatre biomatériaux orthopédiques sous l’effet de l’application de neuro-myélectrostimulation et/ou d’une alimentation enrichie en sel. Nos résultats démontrent que ces deux éléments pourraient avoir un effet délétère pour l'ostéointégration, l'intégrité des implants et la viabilité des cellules musculaires environnantes. Une prothèse adaptée au genou du rat à été conçue afin d’étudier l’effet de l’ATG sur la récupération fonctionnelle et sur les mécanismes nerveux sous-jacents. Nos résultats démontrent que la gonarthrose n'engendre pas de déficits fonctionnels sévères. En revanche, le réflexe H est inhibé et les afférences musculaires de type III et IV sont désensibilisées. Les animaux ayant subi une ATG ont révélé des déficits fonctionnels importants qui tendait à récupérés avec le temps, mais aucune altération de la réponse des fibres afférentes III et IV n'a été observée et le réflexe H est maintenu. Ces résultats soulignent l'adaptation à la prothèse et la présence d'un phénomène de récupération et non d’une compensation. Grâce à notre approche expérimentale innovante, il est maintenant possible de tester in vivo, la biocompatibilité de nouveaux biomatériaux et/ou de nouveaux traitements qui n'ont pas encore d'application clinique. / Total knee arthroplasty (TKA) is the reference treatment for severe osteoarthritis of the knee. This procedure requires heavy surgery which induce many deficits that persist for several years. Moreover, the prostheses have a limited lifetime due to chemical and mechanical stresses occurring in the biological environment. We tested in vivo the effect of the application of neuro-myelectrostimulation and/or high-salt diet on the biocompatibility of four orthopedic biomaterials. Our results show that these two elements could have a deleterious effect on the osseointegration, the integrity of the implants and the viability of the surrounding muscle cells. A prosthesis adapted to knee rat was designed to evaluated the ATG on the functional recovery and on the underlying nervous mechanisms. Our results show that knee osteoarthritis does not cause severe functional deficits. However, H-reflex is inhibited and III and IV afferences are desensitized. Animals with TKA revealed significant functional deficits that tend to recover over time but no impairment of the response of the afferent fibers III and IV was observed and the H reflex was maintained. These results emphasize the adaptation to the prosthesis and the presence of a phenomenon of recovery and not of compensation. Thanks to our innovative experimental approach, it is now possible to test in vivo the biocompatibility of new biomaterials and / or new treatments that have not yet been applied clinically.
323

Biocompatibilidade da vitrocêramica bioativa (Biosilicato®): análises in vitro e in vivo

Kido, Hueliton Wilian 29 August 2011 (has links)
Made available in DSpace on 2016-08-17T18:39:42Z (GMT). No. of bitstreams: 1 4169.pdf: 1866763 bytes, checksum: 38d468ca7232537d6952ee24e68d0593 (MD5) Previous issue date: 2011-08-29 / Universidade Federal de Minas Gerais / Due to limited availability of autogenous bone and of the risks associated with the use of bone allografts, new synthetic materials have been developed in order to replace the bone tissue lost due to trauma or pathological process. The bioactive materials in the form of scaffolds are synthetic materials promising for bone grafting. Several studies suggest that these biomaterials are able to stimulate the proliferation of osteoblasts and osteogenesis at the site of fracture. However, the feasibility of these biomaterials to a clinical application requires the investigation of their biocompatibility. In this context, this study aimed to evaluate the biocompatibility of a scaffold synthesized from a fully crystallized glass-ceramic bioactive quaternary system P2O5-Na2O-CaO-SiO2 (Biosilicate®), through histopathological analysis of the biomaterial implanted in the subcutaneous tissue of rats and the cytotoxicity and genotoxicity analysis of the biomaterial in cell cultures (OSTEO-1 and L929 cells). Histopathologic analysis of the biomaterial was performed using 65 Wistar rats male (210- 260 g), randomly divided into two groups, Control group (n = 3 animals per period) and Biosilicate group (n = 10 animals per period), evaluated at 7, 15, 30, 45 and 60 days after surgery. The animals of Biosilicate group underwent surgery and received a subcutaneous implant of Biosilicate® scaffolds. The animals of Control group underwent surgery but did not receive any biomaterial implant. The cytotoxicity analysis was performed to assess the effect of products leaching from Biosilicate® scaffolds (extracts) on cellular proliferation (MTT). The extracts were evaluated in various concentrations (100, 50, 25 and 12.5%) in experimental periods of 24, 72 and 120 hours in two cell lines (OSTEO-1 and L929). The genotoxicity analysis (comet assay) was performed to assess DNA damage in cells OSTEO-1 and L929 grown in contact with the Biosilicate® scaffolds in different periods of 24, 72 and 96 horas. The statistical analysis of parametrics data was performed by analysis of variance (ANOVA) followed by Tukey post-hoc and the analysis of nonparametrics data was performed by Mann-Whitney test. Both statistical tests were performed with a significance level of 5%. The results of histopathological analysis showed that the animals of the Control group did not present inflammation process, necrotic tissue and fibrous tissue. The animals of Biosilicato group showed a granulation tissue after 7 days of implantation. In the other periods (15, 30, 45 and 60 days) a chronic inflammation process of foreign body, marked by the presence of fibrous tissue and giant cells was observed. No infection or necrotic tissue was observed in any animal. In the analysis of cytotoxicity, it was observed that extracts of Biosilicato® scaffolds did not have any significant effect in reducing cell proliferation OSTEO-1 and L929, and that lower concentrations of the extracts (12.5 and 25%) stimulated the proliferation of both cells in periods of 72 and 120 hours. The analysis of genotoxicity showed that the Biosilicate® scaffolds did not induce DNA damage in the cell lines tested in all experimental periods. The results of this study showed that the Biosilicate® scaffolds presented biocompatibility in vivo and in vitro. / Devido a limitada disponibilidade de osso autógeno e dos riscos associados ao uso de osso alógeno, novos materiais sintéticos vêm sendo desenvolvidos com o objetivo de substituir o tecido ósseo perdido em decorrência de traumatismos ou processos patológicos. Os materiais bioativos na forma de scaffolds são materiais sintéticos promissores para enxertia óssea. Vários estudos sugerem que estes biomateriais são capazes de estimular a proliferação de osteoblastos e a osteogênese no local da fratura. No entanto, a viabilização destes biomateriais a uma aplicação clínica requer o emprego de testes que avaliem a sua biocompatibilidade. Dentro deste contexto, o presente estudo teve como objetivo avaliar a biocompatibilidade do scaffold sintetizado a partir de uma vitrocerâmica bioativa totalmente cristalizada do sistema quaternário P2O5-Na2O-CaO-SiO2 (Biosilicato®), por meio da análise histopatológica do biomaterial implantado no tecido subcutâneo de ratos, e pelas análises de citotoxicidade e genotoxicidade do biomaterial em cultura de células da linhagem OSTEO-1 e L929. A análise histopatológica do biomaterial foi realizada utilizando 65 ratos machos da linhagem Wistar (210-260 g), distribuídos aleatoriamente em dois grupos, Controle (n = 3 animais por período) e Biosilicato (n = 10 animais por período), avaliados em períodos distintos de 7, 15, 30, 45 e 60 dias. Os animais do grupo Biosilicato foram submetidos a uma cirurgia no tecido subcutâneo e receberam um implante de scaffold de Biosilicato®. Os animais do grupo Controle foram submetidos à mesma cirurgia, mas não receberam o implante do biomaterial. A análise de citotoxicidade foi realizada para avaliar os efeitos dos produtos da lixiviação dos scaffolds de Biosilicato® (extratos) na proliferação celular pelo ensaio MTT. Os extratos foram avaliados em várias concentrações (100, 50, 25 e 12,5%) em períodos experimentais de 24, 72 e 120 horas, utilizando duas linhagens celulares (OSTEO-1 e L929). A análise de genotoxicidade (ensaio cometa) foi realizada para avaliar os danos no DNA de células OSTEO-1 e L929 cultivadas em contato com scaffolds de Biosilicato® em períodos distintos de 24, 72 e 96 horas. A análise estatística dos dados paramétricos foi realizada pelo teste de variância (ANOVA), seguido do post-hoc de Tukey, e a análise dos dados não paramétricos foi realizada pelo teste de Mann-Whitney. Ambos os testes estatísticos foram realizados com nível de significância de 5%. Os resultados da análise histopatológica demonstraram que os animais do grupo Controle não apresentaram processo inflamatório, tecido necrótico ou tecido fibroso. Já os animais do grupo Biosilicato apresentaram um tecido de granulação após 7 dias de implantação e nos demais períodos (15, 30, 45 e 60 dias) apresentaram um processo inflamatório crônico de corpo estranho, marcado pela presença de tecido fibroso e células gigantes multinucleadas. Em todos os animais avaliados não foi evidenciado foco de infecção ou tecido necrótico. Na análise de citotoxicidade foi observado que os extratos dos scaffolds de Biosilicato® não possuem efeito significativo na redução da proliferação de células OSTEO-1 e L929, e que as menores concentrações dos extratos (12,5 e 25%) estimularam a proliferação de ambas às células nos períodos de 72 e 120 horas. Na análise de genotoxicidade foi evidenciado que os scaffolds de Biosilicato® não induzem danos do DNA de células de ambas às linhagens testadas em todos os períodos experimentais. Os resultados obtidos neste estudo demonstraram que os scaffolds de Biosilicato® apresentaram biocompatibilidade em experimentos in vivo e in vitro.
324

Citotoxicidade e genotoxicidade de cimentos endodônticos

Bin, Claudia Villela [UNESP] 10 June 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-10Bitstream added on 2014-06-13T19:31:20Z : No. of bitstreams: 1 bin_cv_me_sjc.pdf: 1076251 bytes, checksum: a167eb57ce7c6168b48f17de4f6795bc (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O MTA é um cimento amplamente utilizado na endodontia devido ao potencial indutor da mineralização, sendo empregado em procedimentos de proteção do complexo dentino/pulpar, retrobturação, perfurações radiculares e de furca e em dentes com rizogênese incompleta. Inicialmente esse material não foi preconizado como cimento obturador de canais radiculares. Entretanto, recentemente foi criado um cimento endodôntico resinoso contendo MTA (MTA Fillapex) com essa indicação, porém não há estudos sobre este novo material. Como o MTA é utilizado sobre os tecidos periodontal, ósseo e pulpar, é importante conhecer seus efeitos citotóxicos e genotóxicos, uma vez que, alguns cimentos endodônticos podem liberar componentes tóxicos, prejudicando o processo de regeneração e reparação dos tecidos no qual entram em contato. Assim, o objetivo deste trabalho foi avaliar a citotoxicidade e genotoxicidade do MTA obturador (Fillapex) comparando-o com o MTA reparador e com o AH Plus. Fibroblastos de hamster Chinês (V79) foram colocados em contato com diferentes diluições de meios de cultura previamente expostos a esses materiais. A citotoxicidade foi avaliada através do ensaio de MTT, em espectrofotômetro, para a verificação da taxa de viabilidade celular. A genotoxicidade foi avaliada pela formação de micronúcleos (MNT), para detecção de mutações cromossômicas. A taxa de sobrevivência celular e o número de micronúcleos antes e após a exposição aos cimentos foram estatisticamente analisados pelo teste de Kruskal-Wallis e teste de Dunn (p<0,05). Os resultados mostraram que o MTA reparador manteve a viabilidade celular acima de 50% em todas as diluições. Porém, tanto o MTA Fillapex quanto o AH Plus foram altamente citotóxicos e capazes de aumentar a formação de micronúcleos em 8 vezes em relação ao grupo controle na diluição 1:4, mostrando que são cimentos cito e genotóxicos / The MTA is a sealer widely used in endodontics and for be considered a material that inducing mineralization, can be used in procedures for protection of dentin/pulp complex, retrofilling root and furcal perforations and in teeth with incomplete root formation. Initially this material was not recommended as root canal sealer. However, recently a resin sealer based on MTA (MTA Fillapex) was created for this indication, but there are no studies on this new material. As the MTA is used on the periodontal tissues, bone and pulp, it is important to know the cytotoxic and genotoxic effects, as some sealers can release toxic components, impairing the process of regeneration and repair of tissues in which they come into contact. Thus, the purpose of this study was to evaluate the cytotoxicity and genotoxicity of MTA obturator (Fillapex) comparing it with the MTA repairer and AH Plus. Chinese hamster fibroblasts (V79) were placed in contact with different dilutions of culture media previously exposed to such materials. Cytotoxicity was evaluated by MTT assay in spectrophotometer to check the viability rate and cell survival. The genotoxicity was evaluated by micronucleus (MNT) to detect chromosomal mutations. The cell survival rate and number of micronuclei before and after exposure to the cement were statistically analyzed by Kruskal-Wallis and Dunn test (p<0.05). The results showed that MTA reparative remained cell viability above 50% in all dilutions. However, both the MTA Fillapex and AH Plus were highly cytotoxic
325

Análise das propriedades mecânicas e da biocompatibilidade de cimentos ortodônticos modificados por clorexidina

Sampaio, Gêisa Aiane de Morais 09 July 2015 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2017-03-20T12:03:02Z No. of bitstreams: 1 arquivo total.pdf: 2378282 bytes, checksum: b9d4ce7322ab92c1ce60cf934c7c58ec (MD5) / Made available in DSpace on 2017-03-20T12:03:03Z (GMT). No. of bitstreams: 1 arquivo total.pdf: 2378282 bytes, checksum: b9d4ce7322ab92c1ce60cf934c7c58ec (MD5) Previous issue date: 2015-07-09 / The aim of this study was to evaluate the mechanical properties and biocompatibility of orthodontic GICs with the addition of chlorhexidine digluconate (CX) in 10% and 18% concentrations. The materials were divided into seven groups (n = 12): C (control, Polyethylene), M (Meron Control), M10 (Meron, CX10%), M18 (Meron, CX18%), KC (Ketac Cem Control), KC10 (Ketac CX10%) and KC18 (Ketac CX18%). For biological analysis were used 84 Wistar rats, the cements were inserted into the subcutaneous tissue of rats and biopsies taken after 7, 15 and 30 days. Tissue samples were analyzed morphologically for the presence of inflammatory cellular events (inflammatory infiltrate, edema, necrosis, granulation tissue, giant cells, young fibroblasts and collagen fibers) and immunohistochemical analysis (IH) as the amount of CD68+ cells. Resistance analyzes the diametrical traction (DT), compression (CR) and Shear Bond Strength (SBS) were performed through an universal machine. After completion of the shear strength test, the labial surface of each specimen was evaluated in stereoscopic magnifying glass to quantify the Remnant Index Sticker (RIS). Vickers Microhardness tests were performed using 200g load over 15s. For the morphological and immunohistochemical evaluations were used the nonparametric Kruskal-Wallis and Dunn's test (P<0.05). For evaluation of mechanical properties was used one-way ANOVA followed by multiple comparison test of Tukey (P<0.05). The morphological study of tissues, had inflammatory infiltrated with significant difference between the groups C and KC18 at 7 (P=0.013) and 15 (P=0.032) days. Granulation tissue showed a significant difference between the groups C and M18 (P=0.029), with 7 days. Giant cells (GC) showed differences between the groups C and M18 at 7 days (P=0.013), and KC18 group showed smaller number of young fibroblasts (P=0.031) and collagen fibers (P=0.044) at 7 days. In immunohistochemical analysis, the CG showed significant difference between the M18 group and Groups C, M10 and KC (P=0.001) at 7 days, and between KC18 and the other groups (P=0.001) at 30 days. Macrophages were more expressive in the time period of 7 days in the Groups M18 and KC18, with significant differences with groups M, M10, KC, KC10 and control (P=0.001). TD test showed significant difference between all groups of Meron cement (P=0.001) and between Group KC with groups KC10 and KC18 (P=0.001). The CS test showed no significant difference between the cement Groups of Meron cement (P=0.385), but there was difference between the KC Group with KC10 and KC18 groups (P=0.001). The addition of chlorhexidine modified negatively the mechanical properties of diametral tensile strength, and compressive strength. The histocompatibility analysis showed that the intensity of histological changes in the cements with CX shown to be concentration-dependent, notably 18%. The Meron-CX-10% cement showed the best results of biocompatibility and Ketac-CX-18% more influence in the inflammatory process with a slower tissue repair. / O objetivo desse estudo foi avaliar as propriedades mecânicas e a biocompatibilidade de CIVs ortodônticos com adição de digluconato de clorexidina (CX) em concentrações de 10% e 18%. Os materiais foram distribuídos em sete grupos (n=12): C (Controle, Polietileno), M (Meron Controle), M10 (Meron, CX10%), M18 (Meron, CX18%), KC (Ketac Cem Controle), KC10 (Ketac CX10%) e KC18 (Ketac CX18%). Para análise biológica foram utilizados 84 ratos Wistar machos, os cimentos foram inseridos no tecido subcutâneo dos ratos e as biópsias realizadas após 7, 15 e 30 dias. As amostras teciduais foram analisadas morfologicamente quanto à presença de eventos celulares inflamatórios (infiltrado inflamatório, edema, necrose, tecido de granulação, células gigantes, fibroblastos jovens e fibras colágenas) e uma análise imuno-histoquímica (IH) quanto à quantidade de células CD68+. Análises de resistência à tração diametral (TD), compressão (RC) e resistência de união por cisalhamento (CS) foram realizadas através de uma máquina universal de ensaios. Após a realização do ensaio de resistência ao cisalhamento, a superfície vestibular de cada corpo de prova foi avaliada em lupa estereoscópica para a quantificação do Índice de Remanescente do Adesivo (IRA). A Microdureza Vickers foi realizada com carga de 200g ao longo de 15s. Para as avaliações morfológicas e imuno-histoquímica foram utilizados o teste não paramétrico de Kruskal-Wallis e o teste de Dunn (P<0,05). Na análise estatística das avaliações das propriedades mecânicas foi utilizada ANOVA one-way seguido pelo teste de comparação múltipla de Tukey (P<0.05). O estudo morfológico dos tecidos, apresentou infiltrado inflamatório com diferença significativa entre os grupos C e KC18, em 7 (P=0,013) e 15 (P=0,032) dias. O tecido de granulação demonstrou diferença significativa entre os grupos C e M18 (P=0,029), com 7 dias. As células gigantes (CG) demonstraram diferença entre os grupos C e M18, em 7 dias (P=0,013) e o grupo KC18 demonstrou menor quantidade de fibroblatos jovens (P=0,031) e fibras colágenas (P=0,044), em 7 dias. Na análise imuno-histoquimica, as CG apresentaram diferença significativa entre o Grupo M18 e os Grupos C, M10 e KC (P=0,001), em 7 dias, e entre KC18 e os demais grupos (P=0,001), em 30 dias. Macrófagos foram mais expressivos no período de tempo de 7 dias nos Grupos M18 e KC18, com diferença significante com os outros grupos (P= 0,001). O teste TD demonstrou diferença significativa entre todos os Grupos do cimento Meron (P=0,001) e entre o Grupo KC18 com os Grupos KC e KC10 (P=0,001). O teste RC demonstrou diferença significativa entre todos os Grupos do cimento Meron (P=0,001), e entre o Grupo KC com os Grupos KC10 e KC18 (P=0,001). O teste CS não demonstrou diferença significativa entre os Grupos do cimento Meron (P=0,385), porém houve diferença entre o Grupo KC com os Grupos KC10 e KC18 (P=0,001). A adição de clorexidina modificou de forma negativa as propriedades mecânicas de resistência à tração diametral e resistência à compressão. A análise de histocompatibilidade evidenciou que a intensidade das alterações histológicas nos cimentos com CX demonstraram ser concentração-dependente, notoriamente a 18%. O cimento Meron-CX-10% foi o que apresentou os melhores resultados de biocompatibilidade e o Ketac-CX-18% influenciou mais no processo inflamatório com uma reparação tecidual mais lenta.
326

Avaliação de tratamentos químicos e recobrimento biomimético em cerâmicas de alumina-zircônia

AGUIAR, AMANDA A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:53:38Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:55Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
327

Analise das transformacoes de fase da hidroxiapatita em temperaturas altas por difracao de raios X com aplicacao do metodo de Rietveld

FANCIO, ELIZABETH 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:04Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:53Z (GMT). No. of bitstreams: 1 10452.pdf: 100440947 bytes, checksum: a25045222faf14cf91ac2e310d2ea37a (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP / FAPESP:00/05863-7
328

Incorporacao e liberacao de resveratrol em hidrogeis polimericos / Resveratrol immobilization and release in polymeric hydrogels

MOMESSO, ROBERTA G.R.A.P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:38Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:21Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
329

Obtenção e caracterização de biocerâmicas porosas à base de fosfatos de cálcio processadas com a utilização de albumina / Obtention and characterization of porous bioceramics based calcium phosphate processing by using albumin

RIBEIRO, CHRISTIANE 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:26Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:29Z (GMT). No. of bitstreams: 1 12760.pdf: 9547849 bytes, checksum: 332801af390aaffe9d96d0f596a0e048 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energéticas e Nucleares - IPEN/CNEN-SP
330

Efeito do oxigênio nas propriedades anelásticas da liga Ti-10Mo para aplicação biomédica /

Nogueira, Renata Abdallah. January 2008 (has links)
Orientador: Carlos Roberto Grandini / Banca: Sandra Giacomin Schnider / Banca: Eduardo Carlos Bianchi / O Programa de Pós-Graduação em Ciência e Tecnologia de Materiais, PosMat, tem caráter institucional e integra as atividades de pesquisa em materiais de diversos campi da Unesp / Resumo: A utilização de biomateriais do reparo do tecido ósseo tem revolucionado a Ortopedia e a Odontologia atuais. Um metal estudado para estas aplicações é o titânio e suas ligas, pois possuem um excelente grau de biocompatibilidade com o organismo humano, uma excelente resistência à corrosão em meio biológico e uma ótima relação resistência mecânica/densidade. Estas propriedades são fortemente influenciadas pela presença de lementos intersticiais e as medidas de atrito interno têm sido muito utilizadas para verificar o comportamento destes elementos em materiais. O objetivo neste trabalho foi estudar o efeito de elementos intersticiais nas propriedades da liga Ti-10Mo (% em peso), por meio de medidas de difração de raios X, microscopia eletrônica e varredura, testes de citotoxidade, corrosão e espectroscopia mecânica. As amostras foram submetidas a tratamentos térmicos de recozimento e dopagem com oxigênio. Os testes de biocompatibilidade mostraram que não houve nenhuma resposta indireta. Os extratos dos materiais não interferiram no desenvolvimento, crescimento e proliferação das células. Foi detectada uma melhora na taxa de corrosão, juntamente com um aumento do potencial de corrosão, com a dopagem do material, características estas interessantes para um biomaterial. Os resultados de espectroscopia mecânica mostraram a presença de uma estrutura de relaxação após a dopagem com oxigênio em torno de átomos dos elementos que compõem a liga. Observou-se que a adição de oxigênio intersticial causou um aumento no módulo de elasticidade, o que é ruim quando se trata de um biomaterial para implantes ortopédicos. / Abstract: The use of the biomaterials in the repair of the bone tissue has been revolutionizing the Orthopedics and the Odontology. A metal very studied for these applications is the titanium and its alloys, because they possess an excellent corrosion resistance in a biological media and a good relationship mechanical strength/density. These properties are strongly influenced by the presence of interstitial elements and the internal friction measurements have been a lot used to verify the behavior of these interstitial elements in materials. The objective of this work was to study the effect of interstitial elements in the properties of the Ti-10Mo (%in weight) alloy, through X-ray diffraction, scanning electron microscopy, cytotoxicity tests, corrosion and mechanical spectroscopy. The samples were submitted to heat treatments of annealing and oxygen doping. The biocompatibility tests showed that there was not any indirect cytotoxic answer. The extracts of the materials didn't interfere in the development, growth and proliferation of the cells. An increase in the corrosion rate was detected, with an increase of the corrosion potential, with the oxygen doping, interesting for applications as biomaterial. The mechanical spectroscopy results showed the presence of a relaxation structure after the oxygen doping that was attributed mainly to the stress-induced ordering of the oxygen atoms around the atoms that compose the alloy. It was observed an increase in the elasticity with the oxygen doping, what is bad when it is a biomaterial. / Mestre

Page generated in 0.1106 seconds