• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 164
  • 110
  • 25
  • 9
  • 9
  • 6
  • 4
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 546
  • 255
  • 94
  • 82
  • 73
  • 59
  • 55
  • 48
  • 44
  • 43
  • 42
  • 42
  • 39
  • 37
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
301

Estudo da correlação da densidade mineral óssea obtida pelo método de absorciometria radiográfica com a resistência óssea do terceiro metacarpiano de eqüinos submetido a ensaios biomecânicos / Correlation study between bone mineral density determined by radiographic absorptiometry and bone resistance of equine third metacarpal bone submitted to biomechanial testings

Frazão, Paulo José Riccio 06 August 2008 (has links)
A fundamentação de métodos diagnósticos precoces na ortopedia de eqüinos é de extrema importância clínica, cirúrgica e econômica. O presente estudo teve como objetivo estudar a correlação da densidade mineral óssea do terceiro metacarpiano de eqüinos, obtida pelo método de absorciometria radiográfica, com a resistência dos mesmos quando submetidos a ensaios biomecânicos de compressão e flexão. Utilizaram-se trinta pares de osso terceiro metacarpiano de eqüinos adultos, os quais foram dissecados, radiografados, analisados pelo método de absorciometria radiográfica, submetidos ao estudo tomográfico e a ensaios biomecânicos. Através dos dados obtidos não se observou correlação significativa entre os valores de densidade óptica radiográfica e as propriedades biomecânicas do osso terceiro metacarpiano. Concluiu-se que não se pode inferir que os valores de densidade óssea obtidos pela absorciometria radiográfica do osso terceiro metacarpiano de um eqüino tenha correlação com a capacidade deste osso de absorver cargas de compressão e flexão. / The complete knowledge about non-invasive methods for early disgnostics in equine orthopedy is economicaly important. This experiment has studied the correlation between bone mineral density determined by radiographic absorptiometry and bone resistance of equine third metacarpal bone submitted to both compression and flexion testings. Thirty pairs of third metacarpal bone of adult horses were collected, dissected, radiographed, analysed by the radiographic absorptiometry technique, and submitted to tomographic study and biomechanical testings. The results have shown there is no significant correlation between radiographic bone density values and biomechanical properties of the third metacarpal bone. Therefore, it has been concluded bone mineral density of the third metacarpal bone determined by radiographic absorptiometry do not predict bone capacity to resist compression and flexion loads.
302

\"Avaliação biomecânica da união dente-implante com diferentes tipos de conectores, por meio do método dos elementos finitos\" / Biomechanical evaluation of implant-tooth union with different types of connectors through the finite element method

Betiol, Ederson Aureo Gonçalves 08 February 2007 (has links)
Este estudo apresenta uma análise, por meio do método não linear dos elementos finitos, de uma prótese parcial fixa de quatro elementos, tendo como pilares um dente natural, localizado na região do primeiro pré-molar inferior, e um implante osseointegrado, localizado na região do segundo molar inferior do mesmo hemiarco. Os modelos deste trabalho, foram criados a partir de radiografias periapicais da região posterior da mandíbula, foram digitalizadas e, posteriormente modificadas, dando origem aos modelos computacionais. Com auxílio do programa Ansys® simulou-se uma carga vertical de 175 N, distribuída ao longo dos retentores e pônticos desta prótese. Foram avaliadas três situações: Modelo 1: prótese fixa com conectores rígidos; Modelo 2: prótese fixa com um conector semi-rígido entre o primeiro pré-molar e o segundo pré-molar; Modelo 3: prótese fixa com um conector semi-rígido entre primeiro molar e segundo molar. Para simular os conectores semirígidos foram usados elementos de contato. A partir dos resultados obtidos, percebeu-se, em todos os modelos, que a região óssea que apresentou maior concentração de tensões foi a próximo da crista óssea mesial do implante, sendo os maiores níveis de tensões encontrados no Modelo 2 e os menores no modelo 3. Observou-se também, com relação ao implante, nos Modelos 1 e 3, altos níveis de tensões na região cervical-mesial, próximo da união retentor-pilar intermediário, já no Modelo 2 percebemos um grande aumento das tensões em toda região cervical. Constatou-se também, com relação aos conectores no Modelo 1, altos níveis de tensões entre os pônticos e entre o pôntico e o retentor sobre implante; no Modelo 2, os maiores níveis de tensões foram encontrados entre os molares e, no Modelo 3 os maiores níveis de tensões foram encontrados no conector semi-rígido. / The aim of this study was to analyze, through a non linear method of finite elements, a fixed partial denture of four elements, having natural teeth as an abutment located in the mandibular first pre-molar region and an osseointegrated implant located in the mandibular second molar region in the same hemi-arc, when a vertical load of 175N was applied and distributed over the retainer and pontic. Three situations were evaluated: Model 1: fixed denture with rigid connectors; Model 2: fixed denture with a semi-rigid connector between the first and second pre-molar; Model 3: fixed denture with a semi-rigid connector between first molar and second molar. From the results obtained from all models, the bone region that presented the highest stress concentration was close to the mesial region in the cortical bone of the implant. The highest stress levels were found in model 2 and the lowest in model 3. As regards the implant, in models 1 and 3, higher stress levels were also observed in the cervicalmesial region, close to the intermediate retainer abutment union. In model 2, a great increase of stress was observed in the entire cervical region. Moreover, with regard to the connectors, in model 1, there were high stress levels between the pontics and between the pontic and implant retainer; in model 2 the highest stress levels were found between the molars; and in model 3, the highest stress levels were found at the semi-rigid connector.
303

Estudo comparativo da avaliação da rotação dos joelhos submetidos à reconstrução do ligamento cruzado anterior: feixe duplo x feixe simples / Evaluation of tibial rotational range during dynamic activities: double-bundle vs. single-bundle anterior cruciate ligament reconstruction

D\'Elia, Caio Oliveira 14 January 2015 (has links)
Em uma tentativa de melhor restabelecer a função normal do ligamento cruzado anterior (LCA), foi proposta a técnica de reconstrução do LCA com feixe duplo (FD). Entretanto, a superioridade desta técnica frente à técnica com feixe simples (FS) ainda não está claramente demonstrada no cenário clínico. O propósito do presente estudo foi avaliar e comparar a amplitude de rotação tibial, o máximo de rotação interna e externa, e a força de reação ao solo de joelhos submetidos à reconstrução anatômica com feixe duplo, a joelhos submetidos à reconstrução com feixe simples, durante a realização de tarefas dinâmicas. Para isso, um total de 75 (setenta e cinco) indivíduos foram avaliados (26 reconstruções feixe duplo, 22 reconstruções feixe simples, 27 indivíduos sem lesão do LCA que formaram um grupo controle). Utilizando um sistema de análise do movimento humano, constituído por 4 câmeras para a análise do movimento, os indivíduos foram avaliados em três tarefas de demandas distintas. Utilizou-se a técnica TSACCAST para o cálculo da rotação interna e externa da tíbia. A média da amplitude de rotação tibial, máximo de rotação interna e externa, foi avaliada para cada joelho em cada um dos três grupos. A avaliação clínica destes pacientes foi realizada utilizando-se questionários subjetivo e objetivo (IKDC), assim como artrometria manual. Estas avaliações revelaram que ambos os grupos operados eram semelhantes no que se refere ao resultado clínico pós-operatório. A avaliação da amplitude de rotação tibial, máximo de rotação interna e externa, demonstrou que o joelho operado era semelhante ao joelho não operado e aos joelhos do grupo controle. Também não se verificou diferença significativa nos valores de amplitude de rotação tibial, máximo de rotação interna e externa, quando se comparou o grupo FS ao grupo FD. Desta forma, concluímos que a reconstrução do LCA com a técnica de FS e com a técnica de FD são similares no que se refere ao restabelecimento do controle da rotação da tíbia / In an attempt to better restore the normal function of the two ACL bundles, the ACL reconstruction with two bundles has been proposed. However, the superiority of the double-bundle technique has not been clearly demonstrated in the clinical setting. The purpose of this study was to compare the tibial rotational range, maximal internal and external rotation and ground reaction force of anatomical double-bundle anterior cruciate ligament reconstructed knees with single-bundle anterior cruciate ligament reconstructed knees during three different demanding tasks. A total of 75 subjects, (26 with double-bundle anterior cruciate ligament reconstruction, 22 with single-bundle anterior cruciate ligament reconstruction, and 27 healthy control individuals) were evaluated in this study. Using a 4-camera motion analysis system, motion subjects were recorded performing during three different tasks. Using the CAST technique, the internal-external tibial rotation of both knees was calculated. The mean tibial rotational range, maximum internal and external rotation, for each knee, was evaluated for the 3 groups (double-bundle group, single-bundle group, and control group). Clinical assessment, including objective and subjective IKDC scores, and knee arthrometric measurement, revealed restoration of the reconstructed knee stability with no differences between the two anterior cruciate ligament reconstruction groups. The results demonstrated that both groups resulted in tibial rotation range values that were similar to those in the non-injured knees and those in the healthy controls. There were also no significant differences in tibial rotational range, maximal internal and external rotation and ground reaction force between the DB group and the SB group. Therefore, anatomical double-bundle and single-bundle reconstruction are able to restore normal tibial rotation
304

Efeitos dos alimentos funcionais: probióticos, prebióticos e simbióticos no tecido ósseo de ratos expostos cronicamente a fumaça de cigarro: estudos pré-clínicos randomizados / Effects of functional foods: probiotics, prebiotics and symbiotic tissue of rats bone chronically exposed to cigarette smoke: studies pre-clinical randomized

Tribst, Marcelo Fernandes 21 September 2018 (has links)
Submitted by Michele Mologni (mologni@unoeste.br) on 2019-01-23T12:44:40Z No. of bitstreams: 1 Marcelo Fernandes Tribst.pdf: 777315 bytes, checksum: b27a7e6b55bc34cf1e1df838b6e087c4 (MD5) / Made available in DSpace on 2019-01-23T12:44:40Z (GMT). No. of bitstreams: 1 Marcelo Fernandes Tribst.pdf: 777315 bytes, checksum: b27a7e6b55bc34cf1e1df838b6e087c4 (MD5) Previous issue date: 2018-09-21 / Smoking is a global concern because of the impact on public health, particularly in causing chronic illness and suffering for millions of people and is a leading cause of preventable deaths worldwide. The global annual cost of health services associated with smoking is estimated at US$ 422 billion, equivalent to US$ 56.34 per person. This represents 5.7% of total health expenditure in the world. The blend of cigarette smoke contains around 4.7000 toxic substances that are associated with decreased bone mass and influencing the process of bone healing and remodeling. Bone tissue being multifunctional and subject to cell differentiation at different stages of development is more susceptible to receiving the deleterious action of the main smoking agent of cigarette smoke. Functional, probiotic, prebiotic and symbiotic foods due to their ability to improve intestinal absorption and compete with pathogenic microorganisms may contribute to the improvement of bone quality. The objective of this study was to evaluate the effects of dietary supplementation of probiotic, prebiotic and symbiotic supplements on mineral composition, histomorphometry, biomechanical properties and fractal dimension of the femur of growing rats, chronically exposed to cigarette smoke (PT). Sixty-four young male rats were randomly assigned to eight groups (n = 8): control (C) [basal diet (DB)]; probiotic (Pro) [DB + probiotic (Lactobacillus acidophilus, Enterococcus faecium, Bifidobacterium thermophilum and Bifidobacterium longum (2-5 109 CFU each)], prebiotic (Pre) [DB + prebiotic (mannan oligosaccharide)], symbiotic probiotic + prebiotic + PT), prebiotic smoker (PreT) (DB + prebiotic + PT), smoker control (PT + The rats were sacrificed after 189 days of experimental period, and the results showed that probiotic, prebiotic and symbiotic supplementation improved significantly (P <0.05), as well as symbiotic smoker (SymT) (DB + prebiotic + probiotic + PT). The results showed that the functional food supplementation, probiotic, prebiotic, and the presence of the functional, probiotic, optical or symbiotic improved bone health in growing rats chronically exposed to cigarette smoke. / O tabagismo é uma preocupação global devido ao impacto na saúde pública, particularmente em causar doenças crônicas e sofrimento de milhões de pessoas e é uma das principais causas de mortes evitáveis em todo o mundo. Estima-se em US$ 422 bilhões o custo global anual dos serviços de saúde associados ao tabagismo, equivalente a US$ 56,34 por pessoa. Isso representa 5,7% do gasto total em saúde no mundo. A mistura da fumaça do cigarro contém por volta de 4.700 substâncias tóxicas que estão associados à diminuição de massa óssea e influenciando no processo de consolidação e remodelação óssea. O tecido ósseo por ser multifuncional e sujeito a diferenciação celular em diferentes estágios de desenvolvimento é mais susceptível a receber á ação deletéria da nicotina, principal agente agressor da fumaça do cigarro. Os alimentos funcionais, probiótico, prebiótico e simbiótico, devido sua capacidade de melhorar a absorção intestinal e competir com microrganismos patógenos podem contribuir para a melhora da qualidade óssea. O objetivo desse estudo foi avaliar os efeitos da suplementação na dieta de suplementos alimentares: probiótico, prebiótico e simbiótico, na composição mineral, histomorfometria, propriedades biomecânicas e dimensão fractal do fêmur de ratos em fase de crescimento, expostos cronicamente a fumaça do cigarro (PT). Sessenta e quatro ratos machos jovens foram randomicamente distribuídos em oito grupos (n=8): controle (C) [dieta basal (DB)]; probiótico (Pro) [DB + probiótico (Lactobacillus acidophilus, Enterococcus faecium, Bifidobacterium thermophilum e Bifidobacterium longum (2–5 109 UFC cada)]; prebiótico (Pre) [DB + prebiótico (mananoligossacarídeo)]; simbiótico (Sym) (DB + probiótico + prebiótico); controle fumante (CT) [DB + protocolo de exposição ao tabagismo passivo (PT)]; probiótico fumante (ProT) (DB + probiótico + PT); prebiótico fumante (PreT) (DB + prebiótico + PT); e simbiótico fumante (SymT) (DB + prebiótico + probiótico + PT). Os ratos foram sacrificados após a189 dias de período experimental e os resultados revelaram que a suplementação com probióticos, prebióticos e simbióticos melhoraram significativamente (P<0,05) os parâmetros: P, Ca, Mg, DMO, CMO, resistência, resiliência, dimensão fractal e tamanho da área das diáfises dos fêmures dos ratos expostos cronicamente ou não a fumaça do cigarro. Concluímos que a suplementação dos alimentos funcionais, probiótico, prebiótico ou simbiótico, melhorou a saúde óssea de ratos em fase de crescimento expostos cronicamente a fumaça do cigarro.
305

Simulação dos ventos e tomografia de impulso: sinergia na avaliação do risco de queda de árvores / Wind modelling and impulse tomography: synergy in tree risk assessment

Garutti, Maria Carolina 23 November 2015 (has links)
Os efeitos ambientais negativos da urbanização podem ser mitigados pela presença de espaços verdes dentro e ao redor das cidades. Os elementos mais valiosos de tais áreas são reconhecidamente as árvores. Entretanto, existem também alguns riscos associados com a sua presença, os quais expressam a possibilidade de queda da árvore ou de seus galhos por perda de resistência biomecânica, resultando em perigo de morte e estragos a propriedades, bens e infraestrutura. Nesse sentido, a tomografia de impulso tem se mostrado como uma técnica bastante eficaz em detectar fragilidades biomecânicas no lenho. Considerando ainda que o vento é a principal força dinâmica atuante na copa das árvores, este estudo se propôs a (a) simular o comportamento dos ventos sobre a região do Parque Zoobotânico do Museu Paraense Emílio Goeldi, localizado em Belém-PA, durante quatro eventos de chuvas e ventos fortes usando o ENVI-met, (b) quantificar a perda de resistência biomecânica através da tomografia de impulso em 12 árvores presentes no referido parque e (c) identificar as árvores que possuem um maior risco de queda. Os modelos gerados pelo ENVI-met foram capazes de mostrar zonas de turbulência atuando sobre a copa das árvores tomografadas, e levando em conta a perda de resistência biomecânica, o Guajará foi identificado como apresentando o maior risco de queda entre todas as árvores estudadas. Concluiu-se que o ENVI-met prestou-se perfeitamente para a identificação de zonas de turbulência atuando na copa das árvores. Uma vez conhecidas essas turbulências e considerando a perda de resistência biomecânica acusada pela tomografia, ações de manejo pontuais podem ser propostas e executadas visando diminuir o risco de queda de árvores por ventos fortes em eventos futuros. / Negative environmental effects of urbanization can be mitigated by the presence of green spaces in and around cities. The most valuable elements of such green spaces are considered to be trees. Nonetheless, trees can pose some risks, which encompass the likelihood of mechanical failure of trunk or branches, causing injury to people or damaging buildings and properties. Accordingly, impulse tomography has proven to be a very effective technique in detecting biomechanical weaknesses in the wood. Considering wind as the main dynamic force acting on the tree crown, this study aimed to (a) simulate the behavior of winds over the region of the Goeldi Museum (located in Belém, Pará State, Brazil) during four events of heavy rain and strong winds using the ENVI-met software, (b) quantify the loss of biomechanical resistance for 12 trees located at the Museum and (c) identify trees with high possibility of failure. The models generated by ENVI-met were able to find areas of turbulence influencing the canopy of those trees. Together with the loss of biomechanical resistance, it was possible to identify the Guajará as having the greatest risk of failure among all the analyzed trees. It was concluded that ENVI-met represents a great tool in the identification of turbulence areas that influence trees. Once these areas are identified, and considering the loss of biomechanical resistance given by the impulse tomography, punctual management actions can be proposed and put into action for the sake of reducing risk of failure in future events of strong winds.
306

Estudo biomecânico comparativo de sistemas de fixação de 2,0-mm locking e convencionais em fraturas de ângulo em mandíbulas de cordeiro sob esforços em três eixos no espaço / Comparative biomechanical study of locking and conventional 2,0-mm fixation systems on angle fractures in sheep\'s mandibles under stresses on three axes in space

Saavedra, Milton de Siqueira Ferreira Anzaloni 23 February 2017 (has links)
O objetivo deste trabalho foi avaliar comparativamente a rigidez vertical, horizontal e de resistência à ruptura, com liberdade de movimentos em três eixos no espaço, de mandíbulas fixadas com sistemas 2,0-mm locking e convencionais com uma ou duas placas, em fraturas unilaterais no ângulo mandibular. Vinte mandíbulas de cordeiro, submetidas a osteotomia reproduzindo fraturas, foram divididas em três grupos: F1PC - placa convencional em linha oblíqua; F2PC - duas placas convencionais de modo monoplanar; FL - placa de sistema locking 2,0mm em linha oblíqua. Foi utilizada máquina de ensaio universal, onde foi acoplado suporte metálico com rodas para as mandíbulas. O sistema foi analisado em três diferentes momentos: pré-osteotomia com mandíbulas hígidas e pós-osteotomia/fixação e resistência à ruptura. Os valores de rigidez foram submetidos a análise de variância (p<0,005). Os valores de rigidez vertical (p< 0,0001), horizontal (p= 0,0005) e resistência a ruptura (p= 0,0001) entre pré e pósosteotomia/ fixação apresentaram uma diminuição significante. Na comparação entre os grupos, houve diferença significante para a rigidez vertical (p= 0,009) e o grupo F2PC apresentou maior rigidez. Na comparação entre os grupos, não houve diferença significante para a rigidez horizontal e para resistência a ruptura. Foi concluído que para rigidez vertical, horizontal e resistência a ruptura os valores de pós-osteotomia/fixação foram significantemente menores, o sistema de fixação com duas placas convencionais mostrou maior resistência quanto à rigidez vertical que os demais sistemas e não houve diferença estatisticamente significante na comparação entre os grupos quanto a rigidez horizontal e resistência a ruptura. / The objective of this work was to evaluate the vertical, horizontal and tensile rigidity with freedom of movement in three axes in space, of mandibles fixed with 2.0-mm locking and conventional systems with one or two plates, in unilateral fractures in the Angle of the mandible. Twenty mandibles of lamb, submitted to osteotomy and reproducing fractures, were divided into three groups: F1PC - conventional oblique line; F2PC - two conventional single-mode boards; FL - 2.0mm locking system plate in oblique line. A universal test machine was used, where metal support was coupled with wheels for the jaws. The system was analyzed in three different moments: pre-osteotomy with healthy mandibles and post-osteotomy / fixation and resistance to rupture. The stiffness values were submitted to analysis of variance (p <0.005). The values of vertical rigidity (p <0.0001), horizontal (p = 0.0005) and resistance to rupture (p = 0.0001) between pre and post osteotomy / fixation showed a significant decrease. In the comparison between the groups, there was a significant difference for vertical stiffness (p = 0.009) and the F2PC group presented greater stiffness. In the comparison between the groups, there was no significant difference for horizontal rigidity and for resistance to rupture. It was concluded that for post-osteotomy / fixation values were significantly lower for vertical, horizontal and tensile rigidity, the fixation system with two conventional plates showed greater resistance to vertical rigidity than the other systems and there was no statistically significant difference in comparison between the groups for horizontal rigidity and resistance to rupture.
307

A new approach to apply and develop biomechanical techniques to quantify knee rotational stability and laxity. / CUHK electronic theses & dissertations collection

January 2011 (has links)
Lam, Mak Ham. / Thesis (Ph.D.)--Chinese University of Hong Kong, 2011. / Includes bibliographical references (leaves 110-131). / Electronic reproduction. Hong Kong : Chinese University of Hong Kong, [2012] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Abstract also in Chinese.
308

Bone adaptation under mechanical influence: regional differences in bone mineral density, degree of mineralisation, mirco-arhitecture evaluated by pQCT, BSE imaging and microCT. / CUHK electronic theses & dissertations collection

January 2006 (has links)
Lai Yau Ming. / "August 2006." / Thesis (Ph.D.)--Chinese University of Hong Kong, 2006. / Includes bibliographical references (p. 260-290). / Electronic reproduction. Hong Kong : Chinese University of Hong Kong, [2012] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Abstracts in English and Chinese.
309

Influência das características mecânicas da entressola e da estrutura do cabedal de calçados esportivos na percepção do conforto e na biomecânica da corrida / Influence of mechanical characteristics of midsale and upper structure af running shaes in the comjort and biamechanics ot running

Onodera, Andrea Naomi 26 August 2016 (has links)
o presente estudo teve por objetivo investigar a influência de duas diferentes resiliências de materiais de amortecimento e de dois tipos de cabedais de calçados esportivos na cinemática e cinética de membro inferior e na percepção do conforto durante a corrida. Também investigamos as possíveis relações entre o conforto percebido e as variáveis biomecânicas capturadas. Para tal, foram avaliados 42 corredores recreacionais adultos, com no mínimo de um ano de experiência em corrida de rua, com mínimo de dois treinos regulares por semana, e com volume de treino semanal superior a 5 km. Foram avaliadas quatro condições de calçados aleatorizadas para cada corredor (material de amortecimento de baixa resiliência e cabedal estruturado, material amortecimento de alta resiliência e cabedal estruturado, material de amortecimento de baixa resiliência e cabedal minimalista, e material amortecimento de alta resiliência e cabedal minimalista). Após avaliação antropométrica e postural do complexo tornozelo/pé, os corredores realizaram corridas em uma pista de 25 metros em laboratório. A avaliação biomecânica foi realizada usando seis câmeras infravermelhas (VICON T-40, Oxford, UK) a 300 Hz, sincronizadas a duas plataformas de força (AMTI BP-600600, Watertown, USA) para aquisição da força reação do solo a 1200 Hz, e palmilhas instrumentas com sensores capacitivos (Pedar X System, Novel, Munique, Alemanha) a 100 Hz. A percepção subjetiva de conforto em cada condição foi avaliada por meio de um questionário de conforto para calçados. As comparações estatísticas entre os calçados foram verificadas por meio de análises de variância (ANOVAs) para medidas repetidas, e correlação de Pearson para verificar as relações entre o conforto e as variáveis biomecânicas (a=O,05). Realizou-se uma análise de Machine Learning para capturar variáveis da série temporal completa das curvas de cinemática e cinética que discriminassem os calçados estudados. Construímos uma matriz de entrada nas dimensões 1080 x 1242 para a análise por Machine learning. Os resultados demonstram que há uma interação entre as condições de cabedal e material de amortecimento que faz com que as comparações de resiliência se comportem de forma distinta para cabedais minimalistas e para cabedais estruturados. Contrariamente ao esperado, para os calçados de cabedal estruturado, as resiliências não foram diferentes entre si, e para o cabedal minimalista, os corredores apresentaram impactos mais altos com o material de baixa resiliência. A estrutura de cabedal influenciou a absorção de impacto, onde o cabedal minimalista apresentou impactos mais altos que o cabedal estruturado. Sobre o conforto, a condição de cabedal minimalista e material de baixa resiliência obteve as piores notas em cinco de nove quesitos do questionário. Em alguns quesitos ele foi o pior avaliado dentre todas as demais condições (como no amortecimento do calcanhar e no conforto geral). O cabedal minimalista recebeu pior avaliação que os cabedais estrutura dos no quesito controle médio-lateral da avaliação de conforto. Observou-se que a correlação entre as variáveis biomecânicas e as variáveis de conforto considerando todos os calçados conjuntamente, apesar de apresentarem valores significativos para algumas associações, foram sempre correlações fracas, abaixo de 30%. Ao se analisar cada condição de calçado isoladamente, em algumas se observou correlação moderada entre as variáveis biomecânicas e o conforto (r >31%, p < O,05), o que não se verificou em outras condições de calçados. Cada calçado gera condições particulares que favorecem ou não a associação entre conforto e repostas biomecânicas. Sobre a análise de Machine Learning, a metodologia foi capaz de diferenciar com sucesso os dois materiais de resiliência diferentes utilizando 200 (16%) variáveis biomecânicas disponíveis com uma precisão de 84,8%, e os dois cabedais com uma precisão de 93,9%. A discriminação da resiliência da entressola resultou em níveis de acurácia mais baixos do que a discriminação dos cabedais de calçados. Em ambos os casos, no entanto, as forças de reação do solo estavam entre as 25 variáveis mais relevantes. As 200 variáveis mais relevantes que discriminaram as duas resiliências estavam distribuídas em curtas janelas de tempo, ao longo de toda série temporal da cinemática e força. Estas janelas corresponderam a padrões individuais de respostas biomecânicas, ou a um grupo de indivíduos que apresentaram as mesmas respostas biomecânicas frente aos diferentes materiais de amortecimento. Como conclusão, destacamos que o cabedal tem maior influência que o material de amortecimento quando se trata da biomecânica da corrida e conforto subjetivo. Nos cabedais estruturados, a resiliência do material da entressola não diferenciou a biomecânica da corrida. A resiliência do material de amortecimento causa efeitos importantes sobre o impacto do calcanhar (menores loading rate, frequência mediana, pico de pressão em retropé) durante a corrida em cabedais com pouca estrutura. Alterações biomecânicas devido à resiliência do material de amortecimento parecem ser dependentes do sujeito, enquanto as relacionadas à estrutura de cabedal parecem ser mais sujeito independente. Sugere-se ter cautela ao afirmar que um calçado mais confortável também gerará respostas positivas biomecânicas, pois as associações entre essas variáveis analisando todos os calçados conjuntamente foram sempre correlações fracas. As correlações moderadas e particulares de cada condição de calçado com determinadas variáveis de conforto nos levam a concluir que os materiais aplicados nos calçado favorecem mais ou menos a percepção de determinada característica de conforto / The aim of this study was to investiga te the influence of two cushioning materiais with different resiliencies and two types of uppers of sportive shoes on kinematics and kinetics of lower limb and on the subjective perception of comfort during running. We also investigated the potential relationship between the perceived comfort and biomechanical variables analyzed. For this purpose, 42 adult recreational runners were evaluated. lhey had at least one year of experience on running, minimum of two regular running workouts per week, and weekly training volume above 5 km. We evaluated four randomized shoes conditions for each athlete (Iow resilience cushioning material and structured upper, high resilience cushioning material and structured upper, low resilience cushioning material and minimalist upper, and high resilience cushioning material and minimalist upper). After anthropometric and postura I assessment of the foot/ankle complex, runners held trials on a 25 meters long indoor track. Biomechanical data were collected by six infrared cameras (VICON l-40, Oxford, UK) at 300 Hz, synchronized with two force platforms (AMll BP-600600, Watertown, USA) at 1200Hz, and in- shoe plantar pressure insoles (Pedar X System, Nove\" Munich, Germany) at 100 Hz. Subjective perception of comfort in each shoe condition was assessed by a questionnaire of footwear comfort. lhe statistical comparisons between the shoes were verified by analysis of variance (ANOVA) for repeated measures and Pearson\'s correlation to verify the relationship between comfort and biomechanical variables (a=0.05). We conducted a Machine Learning analysis to capture variables from the complete kinematics and kinetics time series, which would be able to discriminate the studied footwear. We build an input matrix in the dimensions of 1080 x 1242 for Machine Learning analysis. There was an interaction between the upper structure and the resilience of cushioning material that made comparisons between resiliencies to behave differently for minimal uppers and for structured uppers. Contrary to expectation, for structured uppers, resiliencies were not different from each other, and for the minimal upper, runners had higher impact with the low-resilience material. lhe upper structure influenced the absorption of impact, in which the minimalist upper presented higher impacts than the structured upper. About comfort, minimalist upper condition and low resilience materiais had the worst grades for five of nine questions of the questionnaire. In some questions it was the worst of ali conditions (such as for the comfort in the heel cushioning and overall comfort). lhe minimalist upper received worse assessment than the structured uppers in the question about the mediolateral control. It was observed that the correlation between biomechanical variables and comfort, considering ali shoe conditions together, despite having significant values for some correlations were weak correlations (r <30%, p <0.05). When each shoe condition is analyzed alone, some footwear conditions had moderate correlation between comfort and biomechanical variables (r >31%, p <0.05L although the same behavior was not observed in other shoe conditions. Each shoe represents a specific condition that favor or not the association between comfort and biomechanical responses. On Machine Learning analysis, the method was able to successfully distinguish between the two different resiliencies using 200 (16%) of available biomechanical variables with an accuracy of 84.8%, and between the 2 uppers with an accuracy of 93.9 %. Discrimination of the resiliencies resulted in lower levels of accuracy than the discrimination of shoe uppers. In both cases, however, the ground reaction forces were among the 25 most important features. The 200 most relevant features which discriminate the two resiliencies were distribuited in short time windows along the kinematic and force time series. These windows corresponded to individual biomechanical patterns, or patterns of a group of people with similar behavior. In conclusion, we emphasize that the upper has greater influence than the resilience of cushioning material when it is about biomechanics of running and subjective comfort of the shoes. In structured uppers, the biomechanics did not differenciate the resiliencies of the midsole materiais. The resilience of the cushioning material has important effects on the heel impact (Iower loading rate, median frequency, peak pressure in rearfoot) during running on shoes with little structure on the upper. Biomechanical changes due to the resilience of the cushioning material seems to be dependent on the subject, while related to the upper structure seems to be more independent of the subject. It is suggested to be cautious to affirm that more comfortable footwear will also let to positive biomechanical responses. That is because the correlations between these variables when analyzing ali the footwear together were always weak. Moderate and positive correlations of each shoe condition with some of comfort variables lead us to conclude that the materiais applied on each footwear favors more or less the comfort perception
310

Propriedades tensoras em sítio de neurorrafia: estudo experimental em nervos ciáticos de porcos / Tensile properties in site of neurorraphy: experimental study of the sciatic nerves of pigs

Marco Aurélio Sertório Grecco 30 November 2017 (has links)
Este estudo analisou experimentalmente as propriedades de tração no local da neurorrafia em nervos ciáticos seccionados dos porcos. Trata-se de um estudo comparativo entre quatro técnicas de suturas. Foram utilizados 25 nervos ciáticos distribuídos em cinco grupos com cinco nervos cada, de acordo com o tipo de técnica de sutura. Grupo 1: grupo controle composto por nervos, sem lesão; Grupo 2: com nervos lesionados submetidos à sutura epineural; Grupo 3: com nervos lesionados submetidos à sutura epineural e reforço com duas suturas extra lesionais; Grupo 4: composto por nervos lesionados submetidos à sutura epineural e reforço com Ultrapro® (Tela Cirúrgica Sintética não Absorvível) e Grupo 5: com nervos lesionados submetidos à sutura epineural reforçada com duas veias com suturas extra lesionais. A força máxima (N), deformação de ruptura (mm) e energia na força máxima (N.mm) foram medidos em ensaios mecânicos de tração em máquina universal de teste. Os resultados mostraram que não houve diferença estatística entre os Grupos 3 e 4 e Grupos 2 e 5. A sutura do Grupo 3 apresentou maior resistência a tração, maior capacidade de absorver energia. Conclui-se que a técnica de sutura utilizada no Grupo 3 alcançou melhor desempenho. / This study aimed to analyze experimentally, in the laboratory, the tensile properties at the neurorrhaphy site on sectioned sciatic nerves of pigs. A comparative study of four suture techniques. Twenty-five sciatic nerves were used. They were randomly distributed into 5 groups with 5 nerves each, according to the type of suturing technique. Group 1, Control group, consisting of nerves, without injury. Group 2, with injured nerves submitted to epineural suture. Group 3, with injured nerves submitted to epineural suture and reinforcement using 2 extralesional sutures. Group 4, composed of injured nerves submitted to epineural suture and reinforcement with Ultrapro® (Synthetic Non-Absorbable Surgical Patch). And Group 5, with injured nerves submitted to reinforced epineural suture with two veins using extralesional sutures. Maximum force (N), rupture deformation (mm), and energy at maximum force (N.mm) were measured in mechanical trials using a universal test machine. The results showed that there was no statistical difference between Groups 3 and 4 and between Groups 2 and 5. The Group 3 suture presented greater tensile strength, greater capacity to absorb energy. It was concluded that the suture technique used in group 3 achieved better performance.

Page generated in 0.0787 seconds