• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 230
  • 12
  • Tagged with
  • 242
  • 242
  • 45
  • 43
  • 41
  • 39
  • 39
  • 35
  • 34
  • 32
  • 30
  • 25
  • 21
  • 21
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Efeito do meio diluidor e da dose inseminante sobre a congebilidade e fertilidade do sêmen bovino utilizado em programas de inseminação artificial em tempo-fixo(LATF)

Crespilho, André Maciel [UNESP] 26 February 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:16Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-02-26Bitstream added on 2014-06-13T19:38:31Z : No. of bitstreams: 1 crespilho_am_me_botfmvz.pdf: 507525 bytes, checksum: a1c92f545e77b50838125fbea8dfddd6 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A despeito das inúmeras variáveis que influenciam direta e indiretamente a fertilidade das fêmeas bovinas, a qualidade das amostras seminais exerce um papel importante na determinação das taxas de concepção dos programas de inseminação artificial. Os objetivos dessa pesquisa foram comparar a efetividade de dois diluidores de criopreservação de sêmen bovino no processamento de amostras seminais apresentando diferentes concentrações espermáticas em relação aos índices de congelabilidade determinados laboratorialmente (Experimento I) e as taxas de concepção proporcionadas por cada metodologia quando utilizada em programas de inseminação artificial em tempo fixo (IATF) em bovinos (Experimento II). No Experimento I foram utilizados 14 ejaculados de diferentes touros da raça Nelore. Cada ejaculado foi fracionado em oito alíquotas iguais, submetidas a criopreservação com os diluidores Tris-gema de ovo-frutose (meio TRIS) e MKA nas concentrações de 12, 25, 50 e 100 milhões de espermatozóides totais por mililitro de meio, formando oito grupos experimentais em função das variáveis diluidor e concentração. As amostras foram descongeladas a 46 ºC por 20 segundos, avaliando-se os padrões de motilidade através do método computadorizado (CASA), integridade de membrana plasmática (IMP), resistência ao teste de termorresistência rápido (TTR) e taxa de recuperação e IMP após seleção espermática pela técnica de swim-up. Para o Experimento II foram selecionados sete touros utilizados no Experimento I, obtendo-se um ejaculado de cada animal por eletroejaculação... / Although there are many variables which directly or indirectly influence female bovine fertility, the quality of sperm samples plays a important role in the determination of conception rates in artificial insemination programs. The aim of the present study was to compare the efficiency of two bovine semen extenders for sperm freezing with different spermatic concentrations in the freezability determined by lab tests (Experiment I), and conception rates after fixed time artificial insemination (FTAI; Experiment II). In Experiment I 14 ejaculates of different Nelore bulls were used. Each ejaculate was splitsampled in to eight equal parts and then submitted to cryopreservation with Tris-egg yolk fructose (TRIS) and MKA extenders, at concentrations of 12, 25, 50 and 100 millions spermatozoa per milliliter forming eight experimental groups. The samples were thawed at 46 ºC for 20 seconds, and the following parameters were evaluated: sperm motility and movement (by computer-assisted semen analysis - CASA), sperm membrane integrity (SMI), resistance to the fast thermoresistance test (TT), recovery rate and sperm membrane integrity after sperm selection through swim-up technique. Seven of 14 bulls used in Experiment I were selected for Experiment II, and semen was collected from each of the animals by electroejaculation. The seven ejaculates obtained were mixed (semen pool) and cryopreserved, thus forming eight experimental groups according to the freezing extenders and sperm concentrations/straws: TRIS 12, 25, 50 and 100, and MKA 12, 25, 50 and 100...(Complete abstract, click electronic address below)
242

Comparação de métodos auxiliares na identificação de estros em vacas e novilhas mestiças leiteiras

Bonato, Gabriela Lucia 04 June 2012 (has links)
The objective of this study was to evaluate the efficiency of auxiliary tools for the detection of estrus in cows. In experiment 1, we evaluated the efficiency of Estrotect ® in comparison with visual observation in 58 crossbred cows. The animals were divided into two groups: the TAI (n = 21) was subjected to a protocol of a fixed timed insemination (TAI) and 10 days after insemination device was fixed to the animals. In the group PG (n = 37) was administered prostaglandin (Dinoprost Tromethamine, Lutalyse ®, Pfizer) and immediately 25mg/animal/IM pasted adhesive. In the experiment 2, aimed to compare the Estrotect ® with chalk marker in crossbred heifers. After synchronization of estrus with P4 (CIDR) + GnRH - 7 days - PGF2a, heifers were randomly divided into two groups: Group 1 (n = 56) received the Estrotect ® and Group 2 (n = 56) received in the insertion of the marking tail with the chalk marker. The visual detection of estrus was performed daily in the same way in first experiment, from 07:00 to 08:00 and from 17:00 until 18:00. In experiment 2, the devices were only reached two times a day. After detection were artificially inseminated and diagnosed by ultrasound after 30 days in both estudies. In experiment 1, there was no effect of group (P> 0.05) on the efficiency of visual detection of estrus or auxiliary tool. There was no detectable difference between the efficiency of estrus and the visual detection device (P> 0.05) 92.5%. In experiment 2, not detected a group effect (P> 0.05) in the detection of estrus or the range of CIDR removal to the manifestation of estrus. The heat detection and conception rate was 92.86% (52/56), and 46,15% (24/52) for Estrotect® and 85,71% (48/56), and 58.33% (28/48) to chalk marker. It is concluded that the methods of estrus detection aids are effective and help in improving the efficiency of artificial insemination programs. / Objetivou-se neste estudo avaliar a eficiência de métodos auxiliares de detecção de estro em fêmeas bovinas. No experimento 1, avaliou-se a eficiência do Estrotect® em comparação com a observação visual em 58 vacas mestiças leiteiras. Os animais foram divididos em dois grupos: o grupo IATF (n= 21) foi submetido a um protocolo de inseminação artificial em tempo fixo (IATF) e 10 dias após a inseminação foi fixado o dispositivo nos animais. No grupo PG (n=37), foi administrado prostaglandina (Dinoprost Trometamina, Lutalyse®, Pfizer) 25mg/animal/IM e imediatamente colado o adesivo. No experimento 2, objetivou-se comparar o Estrotect® com o Bastão marcador em novilhas mestiças. Após a sincronização do estro com P4 (CIDR) + GnRH 7 dias - PGF2α, as novilhas foram divididas aleatoriamente em dois grupos: Grupo Estrotect (n = 56): recebeu o Estrotect® e Grupo Bastão marcador (n = 56): recebeu a marcação na inserção da cauda com o Bastão marcador. A detecção visual de estro foi realizada diariamente, apenas no experimento 1, das 07:00h às 08:00h e das 17:00h até 18:00h. No experimento 2 os dispositivos foram apenas checados duas vezes ao dia. Após detecção foram inseminadas artificialmente e diagnosticadas após 30 dias por ultrassonografia nos dois estudos. No experimento 1 não foi detectado efeito de grupo (P>0,05) na eficiência da detecção visual de estro ou do método auxiliar. Não foi detectado diferença entre a eficiência da detecção visual de estro e o dispositivo (P>0,05) 92,5%. No experimento 2, não foi detectado efeito de grupo (P>0,05) na detecção de estro nem no intervalo da retirada do CIDR até a manifestação do estro. A detecção de estro e a taxa de concepção foi de 92,86% (52/56) e 46,15%(24/52) para o Estrotect® e de 85,71% (48/56) e 58,33% (28/48) para o Bastão marcador. Conclui-se que os métodos auxiliares de detecção de estros são eficientes e ajudam na melhoria da eficiência dos programas de inseminação artificial. / Mestre em Ciências Veterinárias

Page generated in 0.064 seconds