• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 1
  • Tagged with
  • 6
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Variationer i stegljudsnivå från 20 Hz på grund av mätmetod och utförande i flerbostadshus med trästomme / Variations in impact sound insulation from 20 Hz due to measurement uncertainty and workmanship in dwellings with wood frame construction

Johan, Gruffman January 2017 (has links)
Abstract In this report studies have been made about variations in impact sound insulation from 20 Hz in an industrial, prefabricated, light weight apartment building. The building was constructed by Lindbäcks Bygg AB. Variations was determined from measurement method from SS16283-2:2015 and due to the workmanship of the structure. The different measurement methods from SS16283-2:2015 was also analyzed, the difference in sound pressure level and measurement uncertainty was checked. The objective with this report is to verify if the current standard is adaptable for measurement from 20 Hz in a prefabricated apartment building. Also verifying the standard and if possible make the procedure of measurement more effective. Measurement of sound insulation were executed in 12 apartments. The apartment was of the same prefabricated module. From the measurements the impact sound insulation was calculated and was presented in both measurement methods and from 20 Hz. Variations of impact sound insulation was quantitated from 20 Hz with one normalized value for a simulated reverberation time under 50 Hz and one without correction of reverberation under 50 Hz. The calculated value of variation due to the measurement method was not of some significant difference, this indicate the current standard is adaptable for measurements from 20 Hz. The variation due to workmanship was quantitated, but no statistical analyze could be made cause lack amount of measurements. A significant difference in sound pressure level was identified between measurement methods, this was assumed to be caused by the room modes. / I detta examensarbete utvärderas variationer i stegljudsnivå från 20 Hz i ett industriellt prefabricerat flerbostadshus uppfört med trästomme. Variationerna sett till mätmetod och utförandet av konstruktionen kontrollerades. Det genomfördes även en kontroll mellan mätmetoder angivna av SS16283-2:2015 om det uppstod någon skillnad sett till uppmätt ljudtrycksnivå och mätosäkerhet. Målet med projektarbetet var att kontrollera om går att anpassa dagens standard för mätningar från 20 Hz. Samt kontrollera de olika mätmetoder angivna av SS16283-2:2015 kvalitet, detta för att effektivisera och ge möjlighet till en högre kvalitet av genomförda mätuppdrag för Tyréns AB. Ljudmätningar genomfördes i ett industriellt prefabricerat flerbostadshus uppfört av Lindbäcks Bygg. Byggnadsprojektet kallas för Sofiehem 61 och är ett studentboende. Byggnaden består av fem våningar varav en vindsvåning som enbart är till för installationer. Varje plan består av åtta lägenheter bortsett bottenplan där enbart sju lägenheter finns. Det genomfördes totalt mätningar i 12 identiska lägenheter uppförda med samma byggnadsmodul. Från de genomförda mätningarna kunde stegljudsnivån beräknas och redovisas utifrån de aktuella mätmetoderna och från 20 Hz. Det uppstod ingen markant variation sett till mätmetoden vid mätningar ner till 20 Hz, detta indikerar på att dagens mätstandard går att tillämpa för mätningar ner till 20 Hz. Variationen sett till stegljudsnivå för konstruktionens utförande kvantifierades, dock genomfördes mätningar på för få mätobjekt för att erhålla statistiskt korrekta resultat. Det uppstod däremot en skillnad sett till stegljudsnivåer vid val av mätmetod angiven av S16283- 2 2015. Detta bedömdes bero på rummets egenfrekvens.
2

Fönstrets akustiska påverkan på lättbyggnadskonstruktioner

Sandin, Elin January 2020 (has links)
Examensarbetet sker i samarbete med ett företag som bygger flerbostadshus i trä, genom industriell produktion av moduler. Tyréns har tillsammans med företaget, Lindbäcks Bygg, upptäckt att fönster med hög ljudisolering inte presterar som förväntat i deras ytterväggar, byggda i lättbyggnadsteknik. Med prestatanda menas ljudisolering mot ljud utanför byggnad. Detta är konstaterat i två tidigare projekt med Lindbäcks Bygg. Även i diskussion med andra lättbyggnadstillverkare har även problematiken bekräftats. Målet är att finna lösningar för att förbättra den sammansatta ljudisoleringen för ytterväggar i lättbyggnadsteknik tillsammans med fönster. Vidare är syftet att förstå interaktionen mellan fönsters och ytterväggs ljudisolerande egenskaper i lättbyggnadsteknik. I detta examensarbete har fältmätningarna valts som metod. Mätningar gjordes på riktiga bostadsmoduler på en byggarbetsplats. Först testades originalfönstret av typen 2+1 med Rw = 43 dB och Rw + Ctr = 37 dB och sedan gjordes tester med ett fönster med hög ljudisolering av typen 2+1 med Rw = 50 dB och Rw + Ctr = 46. Mätningarna gjordes enligt standard 16283-3 vilket innebär att högtalaren ställs upp i en vinkel på 45º. I examensarbetet testades bortmontering av karmskruv och isolering i smyg inne, ute och både och. Vidare testades olika nischdjup och svällisten studerades. Fönstrets höga ljudisolering uppnåddes inte vid placering mitt i väggen (R´45 + Ctr = 6 dB sämre än förväntat) helt i enlighet med tidigare resultat. Bortmontering av karmskruven gav inte någon betydande skillnad i ljudisolering utan gav 1 dB försämring med anpassningsterm. Isolering i smygen på insidan gav en liten förbättring på 1 dB och testades både i originalposition men även vid förflyttning utåt i nischen. Dock är denna lösning inte möjlig att använda i praktiken. Denna förbättring kan bero på skillnader i nischhöjd ute och inne men även för att isoleringen kan ta upp en del av vibrationerna från fönstret. Förändring av nischdjupet gav en stor skillnad. En förflyttning från originalplaceringen mitt i väggen gav betydande förbättringar av ljudisoleringen. Förflyttning utåt gav en förbättring på 1 dB men vid förflyttning inåt gick reduktionstalet från 41 dB till 48 dB och R’45° + Ctr gick från 37 dB till 43 dB. Vilket är samma resultat som labbtesterna (-3dB). Med fönstret monterat längst in mot rummet presterade alltså fönstret förväntad ljudisolering. Slutsatserna från studien är att den dominerande överföringsvägen för ljud utifrån och in är genom fönstret och inte genom flanktransmission via karmskruvarna ut i väggen. Vidare är slutsatsen att fönstrets placering i nischen har en stor betydelse och vid höga ljudkrav och fönster med hög ljudreduktion så rekommenderas att ändra placeringen i fönstret. Ytterligare en slutsats från denna studie är att fönster i lätta väggar inte behöver prestera sämre än i tunga väggar eftersom resultat uppnåddes som är jämförbara med labbresultat.
3

Lätta väggar, högt buller / Light walls, loud noise

Dahlström, Hannes, Dyk-Strömberg, Alexander January 2021 (has links)
En av modern tids största miljöproblem anses vara buller. Bland annat kan nedsatt fysisk hälsaoch mental stress förekomma för människor som utsätts för bullerexponering. Ökande önskan om god akustisk miljö är idag i konflikt med att pågående urbanisering gör att vi utsätts för ökad bullerexponering i våra bostadsmiljöer. Urbaniseringen har lett till framställningen av en förordning som är fördelaktig för mer expansivt bostadsbyggande i bullerutsatta miljöer.Förordningen möjliggör byggnation vid högre trafikbullernivåer än tidigare tillåtet. Med avseende på tidigare kravnivåer har fasadväggar generellt ansetts ha mer än tillräcklig ljudisoleringsförmåga att klara trafikbullernivåerna. Till följd av nu gällande förordning är det nu inte lika entydigt att fasader med lättbyggnadsteknik har tillräckligt god ljudreduktionsförmåga. Av dessa anledningar är det aktuellt att studera hur bra fasader av lättbyggnadsteknik klarar att reducera bullret för att erfordra en kravställning på ekvivalentljudtrycksnivå inomhus som motsvarar ljudklass C eller B.Studien syftar till att undersöka om lättbyggnadsteknik är lämpligt i bullerutsatta områden som tillåts av dagens bullerkravställning. Målet är att erhålla en konstruktion i lättbyggnadsteknik som lämpas att byggas i denna höga bullerexponering. Frågeställningar ämnar att reda ut hur resultaten på väggarnas ljudisoleringsförmåga förhåller sig mellan de olika empiriska insamlingarna och dessutom hur de presterar gentemot dagens kravställningar.I rapporten genomförs akustiska fältmätningar av reduktionstalet (ljudisoleringen) enligt svenskstandard på tre fasadväggar av lättbyggnadsteknik. Fasadväggskonstruktionerna modelleras även i programvaran Insul 8 för att genom detta erhålla väggarnas beräknade reduktionstal. På en av fasadväggarna undersöks även det modellerade reduktionstalets variation följandemodifieringar av väggkonstruktionens uppbyggnad. Väggarna jämförs även med riktvärden förtre referensväggar redovisade i litteratur.Genom det teoretiska underlaget har resultaten från mätningarna, modelleringarna och litteratur-riktvärden utvärderats i förhållande till om de uppnår kravnivåer på ekvivalent ljudtryck inomhus. Resultaten för rådande fallundersökningar visar att alla undersökta väggar har erforderlig ljudreduktionsförmåga för att uppnå samhällets minimikrav (ljudklass C) då ljudreduktionen dimensioneras med väggen som dimensionerande fasadelement. Med avseende på fönster som dimensionerande fasadelement klarar två av sex väggar ej att uppnå inomhusnivåer för ljudklass C. Då kravnivåerna avser att upprätta en ännu bättre ljudmiljö (ljudklass B) än minimikraven så erhåller fyra av sex väggar denna erforderliga ljudisolering med vägg som dimensionerande element. För att uppnå ljudklass B då fönstrets ljudreduktion är dimensionerande så har en fältmätning, en referensvägg och två väggmodelleringar (utan modifieringar) erforderlig ljudisolering.Slutsatserna påvisar att ljudisoleringen är generellt sett erforderlig för väggarna i lättbyggnadsteknik, även i bullerutsatta områden som tillåts av dagens kravställning. Att kunnauppnå en god ljudmiljö (ljudklass B) avseende ekvivalent ljudtryck inomhus är däremot ej självklart då väggar i lättbyggnadsteknik byggs på bullerexponerad plats. Möjligheten att förbättra reduktionstalet är möjligt och tillämpbart genom att öka massan eller minska styvheten på väggen om reduktionstal är undermåliga. / This thesis evaluates whether walls with light-frame construction are suitable to build in areas with high sound pressure levels, allowed by Sweden’s law regarding loud traffic noise nearbuildings. Previous consensus has been that exterior walls have sufficient sound insulation,regarding sound pressure levels by the residence-façade generated from traffic noise, to achieverequired indoor sound pressure levels. Due to the ongoing urbanization in Sweden, a law haspassed that increased the allowed levels of equivalent sound pressure by a residence-façade. Therefore, it has become relevant to examine if light-frame construction façades really do have sufficient sound insulation.In the study, field measurements are made on three façade walls to determine their noise reduction properties. The values from the measurements are compared to the sound insulation capacity of software-built wall-models with the same wall constructions as the field measured walls. Both the measured and the modelled walls sound insulation is also compared parallel to insulation values for light-frame construction walls found in literature. The values of the walls sound insultation are also evaluated regarding high but occurring sound pressure levels by facades and demanded levels of sound pressure indoors. Modifications are made to the construction of one modelled wall to quantify the improvement in sound insulation of the walls derived from the investigated construction-modifications.The results conclude that the examined light-frame construction walls are indeed sufficient in the aspect of sound insulation to merely satisfy the laws. The walls sound insulation is not as unambiguously sufficient when establishing what is considered a good indoor acoustic environment, instead of only achieving minimum levels required by law.
4

Vibration reduction over junctions in buildings / Vibrations förändringar över knutpunkter i byggnader

Forsberg, Alexander, Wali, Aras January 2021 (has links)
Structure borne sound can travel multiple paths from one office to another and choosing to sound insulate a specific building element can be difficult since all the building elements are connected together and form a coupled system. The current approach by engineers when investigating transmission paths between spaces in a building is using a computer model and assuming that the junctions are firmly clamped or free. Standardized measuring methods includes a large amount of measuring points on each side of a junction and excitation over large areas. This study intends to investigate if it is possible to gain valuable information with a small amount of measuring points in a field measurement by comparing the data with an analytical model and a finite element model. The field measurement consisted of excitation from an impulse hammer from two excitation points and three accelerometers placed on each side of the junctions and on both sides of the separating wall. The measurement took place in a office building, with no information about the structure other than length, width and thickness of the elements.The reduction over the junctions varied with frequency and no general conclusion could be made about the transmission paths. The results showed high vibration reduction over the junction in low frequencies which then decreased in higher frequencies. Measurement results in low frequencies coincided with the analytical model, that vibration reduction is high over a junction for lighter separating walls in low frequencies and decrease quickly as frequency increases. Different results over each junction was obtained depending on excitation point, which indicates that there is flanking transmission along with the fact that it is a complex coupled system. / Strukturburet ljud kan färdas flera olika vägar från ett kontor till ett annat och att ljudisolera en specifik vägg kan vara svårt då alla byggnadselement är ihopkopplade och skapar ett kopplat system. Den nuvarande metoden ingenjörer använder för att undersöka transmissionsvägar mellan rum är att skapa modeller i datorprogram där antaganden att byggnadselementen är fast inspända eller fritt upplagda är gjorda. Standardiserade mätmetoder använder sig av en stor mängd mätpunkter på båda sidor om knutpunkterna och excitationer över stora ytor. Den här studien avser att undersöka möjligheten att erhålla värdefull information med ett fåtal mätpunkter i en fältmätning genom att jämföra den samlade mätdatan med en analytisk modell och en FEM modell. Fältmätningen består av excitation med en impulshammare i två excitationspunkter och tre accelerometrar på vardera sida om knutpunkterna och båda sidor om skiljeväggen. Mätningen utfördes i en kontorsbyggnad, utan någon information om strukturen förutom längd, bredd och tjocklek på byggnadselementen.Reduktionen över knutpunkterna varierade i frekvens och inga generella slutsatser kunde göras angående transmissionsvägar. Resultaten visade hög reduktion i vibrationsskillnad över knutpunkterna i låga frekvenser vilket minskade med ökad frekvens. Mätningsresultaten stämde överens med den analytiska modellen i låga frekvenser, med avseende på att reduktionen över knutpunkter med lätt skiljevägg är hög i låga frekvenser och avtar med ökad frekvens. Resultaten över knutpunkterna var beroende på val av excitationspunkt vilket indikerar att mätresultaten innehåller flankerande transmissioner och att det är ett komplext kopplat system.
5

Funktionskontroll av stegljudsisolering vid konstnärligt campus i Umeå / Function control of impact isolation at school of fine art in Umeå

Lindberg, Patrik January 2013 (has links)
This report's aim is that by field measurements determine the function of Aprobo soundproofing material dB2 for reducing impact sounds, the measurements is done in “the school for fine art” in Umeå also known as “konstnärligt campus building nine”. The construction technique is used in areas sensitive to impact sound between different floors in the building. The measurement’s is also to do a function control of the buildings sound quality compared to Swedish and European standard when it comes to air sound, impact sound and reverberation time . The report have concluded that the function of Aprobo dB2 as an impact isolation is correct but that it have no positive result on the air sound isolation in nether horizontally or vertically when controlled in weighted values. The report’s conclusions can be used in future projections of buildings that suffer from impact sensitivity in vertical direction, it can also be used to project for impact sound isolation in horizontal direction but that it is important to choose the proper construction above the isolation for that to work. / Syftet med detta arbete är att genom fältmätning fastställa funktionen av Aprobos ljuddämpningsmatta dB2 och hur väl den reducerar stegljud. Mätningarna är genomförda på konsthögskolans byggnad i Umeå även kallad byggnad nio på konstnärligt campus. Den aktuella tekniken används i konstruktioner känsliga för ljudtransport mellan våningsplan. Undersökningens syfte är även att göra en funktionskontroll av byggnadens ljudstandard jämnfört med Svensk och Europeisk standard för såväl luftljud, stegljud och efterklangstid.  Rapporten har kommit fram till att Aprobos konstruktionslösning med dB2 har en positiv inverkan på stegljudsisolering men att den ej har någon positiv inverkan på luftljudsisolering vare sig i vertikal eller horisontalled när de kontroleras i vägda värden. Rapportens slutsats går att användas i framtida projekt av byggnader som är känsliga för stegljud i vertikalled, den går även använda vid projektering av stegljud i horisontalled men då är det viktigt att rätt konstruktionslösning väljs för övergolvet.
6

Jämförelse av ljudisolering i öppna och stängda planlösningar baserat på DnTw-mätningar / Comparison of sound insulation in open and closed of floorplans based on DnTw measurements

Nilsson, Evelyn, Parkkonen, Jonna January 2023 (has links)
En god akustisk inomhusmiljö är idag en nödvändighet för att motverka negativ påverkan på människors hälsa. Framför allt belyser tidigare studier problematik kring störd eller uteslutensömn till följd av buller och övriga miljöförsämrande ljud. Förutom de direkta konsekvenserna av utesluten eller störd sömn som trötthet och minskad koncentrationsförmåga, kan denna avsaknad av vila även leda till hjärt-kärlsjukdomar, stress och depression. Fler bostäder på begränsad yta leder till lösningar som förutsätter ett välplanerat bostadsbyggande för att tillgodose samhällets behov. Loftgångshusen blev vanligt förekommande i Sverige under 1960-talet då de hade ekonomiska fördelar och de kunde sammankoppla fler lägenheter till ett och samma hisschakt. Bostadstypen förekommer än idag och är därav aktuell vid undersökning avljudförhållanden intill boendeytor. Vanlig planlösning för dessa lägenheter är att placerasovrummet i direkt anslutning till loftgången. Då Boverket ställer krav på ljudisoleringen frånloftgång in till utrymme för vila eller sömn, är det aktuellt att undersöka hur den rådandeplanlösning bäst skall utformas för att nå upp till de krav som ställs. Studien syftar till att undersöka eventuella avvikelser för DnTw-värden vid varierande planlösning för beräknade och uppmätta värden i fältmätning. Dntw-värdet är ett mått på ljudisolering hos ett element där hänsyn tas till efterklangstiden. Vidare kommer studien att undersöka hur dessa potentiella avvikelser vid fältmätning korrelerar med de beräkningar som idag sker vid projektering. Målet är att identifiera de skillnader som finns mellan beräknade och uppmätta ljudisoleringsvärden vid projektering av fasadelementens ljudisoleringsvärde då planlösningen för mottagarrummet varierar. De planlösningar som undersöks kommer i arbetet att relateras till som ”öppen” respektive ”stängd”. Resultatet som åstadkommits grundas i utförda fältmätningar av luftljudsisolering på tre aktiva byggprojekt, modellering i programvaran Insul 9 samt teoretiskt beräknade värden förskiljeytans DnTw-värde. Samtliga mätningar och beräkningar har genomförts enligt svensk standard. Den modellering som gjorts avser skiljeytans olika element där resultatet har agerat kontroll mot de värden som tillhandahållits från aktuella bygghandlingar. Skiljekonstruktionens prestation mot de varierande planlösningarna jämförs mot varandra för att studera de skillnader som uppstår. Resultatet visade att en obetydlig skillnad uppstod för DnTw-värdet när mottagarrummets volym varierade vid fältmätning. Denna avvikelse skiljde sig från den teoretiskt beräknade skillnaden mellan öppen och stängd planlösning. Alltså, det teoretiska värdet är striktvolymberoende. Detta volymberoende kan dock inte ses vid mätning i fält. Alltså är det teoretiskt beräknade DnTw -värdet för skiljeytan högre än ytans faktiska prestation i fält. / A good acoustic indoor environment is today a necessity to prevent effects on people’s health. Current research provides clear indications of how prolonged exposure to unwanted noise can lead to various conditions such as stress, depression, and cardiovascular diseases. Studies highlight the problems related to disturbed or excluded sleep due to bothersome unwanted noise. This demand for a quiet and sound indoor environment does not align with the constant urbanization taking place in society. One prevalent type of housing is a residence with an exterior corridor connecting the apartments. The common layout for these apartments is to place the bedroom directly adjacent to the corridor. Since the National Board of Housing, Building, and Planning (Boverket) imposes requirements for sound insulation between the corridor and the bedroom, it´s of relevance to investigate the impact of the floorplan to meet these required standards. This thesis aims to investigate any deviations in DnTw values with varying apartment layouts for calculated and field-measured values. The DnTw-value refers to sound insulation in an element, based on the reverberation in the receiving room. Further investigation is made to answer whether these potential deviations in field measurements correlate with the calculations made during the engineering process. The goal is to identify the differences between calculated and measured values for sound insulation and the effect of a varying floor plan. The results showed an insignificant difference in the measured DnTw value with varying volume. However, this deviation was different from the theoretically calculated difference between open and closed apartment layouts. Thus, the DnTw value is more prominently value dependent in theory compared to the values measured in the field. This leaves a higher DnTw value for the separating surface than the actual performance in the field.

Page generated in 0.0323 seconds