• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 1
  • Tagged with
  • 10
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Ljudisoleringsegenskaper hos fönsterkonstruktioner

Dahlman, Anders, Bengtsson, Björn January 1980 (has links)
QC 20110616
2

Stomljudsisolering : jämförelse av processmöjligheter

Parkkila, Teija, Jonson, Johan January 2003 (has links)
No description available.
3

Stomljudsisolering : jämförelse av processmöjligheter

Parkkila, Teija, Jonson, Johan January 2003 (has links)
No description available.
4

Ljudisolering i dubbelväggskontruktioner av KL-trä : Uppskatta reduktionstal med analytisk modellering

Remnegård, Erik January 2020 (has links)
Rapidly growing cities require that new residential buildings be created at a matching pace. Moreover, ambitious environmental goals not only call for these buildings to be constructed swiftly, but also in a sustainable manner. Cross-laminated wood, abbreviated CLT, may partly offer a solution to these challenges. During a period when wood was prohibited to serve as a framework material in buildings higher than two stories, the research examining wood as a building material suffered a setback. While the interest in wooden buildings has increased in recent years, there are still uncertainties regarding several of the material’s properties, such as its acoustics. Being able to predict whether a structure will meet the desired acoustic requirements, is vital to contractors and clients in the building industry, as later reconstructions often result in considerable added costs and delays. Thus, tools that help predict acoustic properties are in high demand and may help wood become a more attractive choice of building material. Aiming at decreasing the total thickness of a double-wall without compromising its sound insulation ability, an experiment examining the effects of perforation of a CLT panel and its impact on the sound reduction index (SRI), was conducted. Results indicated that it may be possible to decrease the total thickness of a double wall by perforating the panel, while maintaining and in some cases, increasing the SRI. This study is based on an analytical calculation model which predicts the sound insulation properties of single- and double walls, measured in SRI [dB]. The original model was produced by Sharp and later modified by Ljunggren to obtain a better match for CLT panels. The sample data, provided by the company Martinsons AB, consisted of 32 unique double-wall configurations of which the SRI was modelled. As the original model only applied to configurations assuming total insulation of the cavity, an extension was calculated to apply to configurations comprising no or partial insulation. To validate the model, results were then compared to available data from onsite measurements provided by Tyréns, as well as calculations by Ljunggren. As comparable data is limited and most modelled configurations had no corresponding onsite measured SRI, the results of this study may serve as an indication of what sound insulation quality to expect for those configurations. The predicted SRI for which a corresponding measured SRI did exist, showed good agreement, with deviations of 1-2 dB. Compared to measurements conducted by Tyréns, the modelled SRI were approximately 3-6 dB higher. Measured SRI are under the influence of flanking transmission which often results in it being the lower value, when compared to modelled SRI. However, the relative difference between the two values can still serve as a useful tool. To strengthen these findings and confirm the validity of the model, further research examining a wider range of measurements and comparisons with modelled results should be conducted. / Träcentrum Norr
5

Acoustic properties of a 5G Telecom Equipment Shroud Design for Noise suppression / Huvdesign för ljudämpning till 5G Teleutrustning

Andersson, David January 2021 (has links)
As technology moves forward it has a tendency to consume more and more power that needs to be cooled by bigger and louder fans, this is especially true for the new generation of 5G radio equipment. This Master thesis is a collaboration with Ericsson and attempts to construct a shroud for containing a number of 5G radio units whilst attenuating the fan noise of the units as effectively as possible. In this project are air ducts used and at the ends silencers are created utilizing the Cremer impedance; the optimal wall impedance for damping an acoustic mode of a propagating wave. To predict the result, a simplified model in an acoustic FEM program was also explored and compared to the sound level of the constructed shroud. The finished shroud successfully reduces the noise of the radio units by 13 dB(A) while causing an increase in temperature of between 2.8°C to 5.9°C. This result was deemed to be a success and the Cremer impedance approach of reducing noise is therefore advised for future development. / Allt eftersom tekniken går framåt tenderar den att också förbruka mer och mer energi som i sin tur måste kylas av kraftigare och mer högljudda fläktar, detta fenomen är särskilt påtagligt när det kommer till den senaste generationens radioutrustning för 5G. Detta examensarbete är ett samarbete mellan KTH och Ericsson med avsikt att skapa en kåpa som är designad för att innesluta ett bestämt antal 5G radiomoduler. Denna kåpa ska i så stor utsträckning som möjligt dämpa det fläktinducerade bullret. I det här projektet nyttjas kanaler med ljuddämpare vid ändarna som dämpar ljudet med hjälp av Cremerimpedans, dvs: den väggimpedans som optimalt dämpar en akustisk mod. För att kunna förutspå resultatet skapades en förenklad akustisk modell i ett FEM program. Resultatet från denna modell jämförs sedan med ljudeffektnivån från slutmätningen av den färdiga kåpan. Resultatet från slutmätningen visar att kåpan lyckas sänka radioenheternas totala ljudeffektnivå med 13 dB(A) samtidigt som en temperaturökning på mellan 2.8°C och 5.9°C erhålls. Det här resultatet bedöms vara en framgång, vilket leder till slutsatsen att ljuddämpning med användning av Cremerimpedans rekommenderas för vidare arbete.
6

Jämförelse av ljudisolering i öppna och stängda planlösningar baserat på DnTw-mätningar / Comparison of sound insulation in open and closed of floorplans based on DnTw measurements

Nilsson, Evelyn, Parkkonen, Jonna January 2023 (has links)
En god akustisk inomhusmiljö är idag en nödvändighet för att motverka negativ påverkan på människors hälsa. Framför allt belyser tidigare studier problematik kring störd eller uteslutensömn till följd av buller och övriga miljöförsämrande ljud. Förutom de direkta konsekvenserna av utesluten eller störd sömn som trötthet och minskad koncentrationsförmåga, kan denna avsaknad av vila även leda till hjärt-kärlsjukdomar, stress och depression. Fler bostäder på begränsad yta leder till lösningar som förutsätter ett välplanerat bostadsbyggande för att tillgodose samhällets behov. Loftgångshusen blev vanligt förekommande i Sverige under 1960-talet då de hade ekonomiska fördelar och de kunde sammankoppla fler lägenheter till ett och samma hisschakt. Bostadstypen förekommer än idag och är därav aktuell vid undersökning avljudförhållanden intill boendeytor. Vanlig planlösning för dessa lägenheter är att placerasovrummet i direkt anslutning till loftgången. Då Boverket ställer krav på ljudisoleringen frånloftgång in till utrymme för vila eller sömn, är det aktuellt att undersöka hur den rådandeplanlösning bäst skall utformas för att nå upp till de krav som ställs. Studien syftar till att undersöka eventuella avvikelser för DnTw-värden vid varierande planlösning för beräknade och uppmätta värden i fältmätning. Dntw-värdet är ett mått på ljudisolering hos ett element där hänsyn tas till efterklangstiden. Vidare kommer studien att undersöka hur dessa potentiella avvikelser vid fältmätning korrelerar med de beräkningar som idag sker vid projektering. Målet är att identifiera de skillnader som finns mellan beräknade och uppmätta ljudisoleringsvärden vid projektering av fasadelementens ljudisoleringsvärde då planlösningen för mottagarrummet varierar. De planlösningar som undersöks kommer i arbetet att relateras till som ”öppen” respektive ”stängd”. Resultatet som åstadkommits grundas i utförda fältmätningar av luftljudsisolering på tre aktiva byggprojekt, modellering i programvaran Insul 9 samt teoretiskt beräknade värden förskiljeytans DnTw-värde. Samtliga mätningar och beräkningar har genomförts enligt svensk standard. Den modellering som gjorts avser skiljeytans olika element där resultatet har agerat kontroll mot de värden som tillhandahållits från aktuella bygghandlingar. Skiljekonstruktionens prestation mot de varierande planlösningarna jämförs mot varandra för att studera de skillnader som uppstår. Resultatet visade att en obetydlig skillnad uppstod för DnTw-värdet när mottagarrummets volym varierade vid fältmätning. Denna avvikelse skiljde sig från den teoretiskt beräknade skillnaden mellan öppen och stängd planlösning. Alltså, det teoretiska värdet är striktvolymberoende. Detta volymberoende kan dock inte ses vid mätning i fält. Alltså är det teoretiskt beräknade DnTw -värdet för skiljeytan högre än ytans faktiska prestation i fält. / A good acoustic indoor environment is today a necessity to prevent effects on people’s health. Current research provides clear indications of how prolonged exposure to unwanted noise can lead to various conditions such as stress, depression, and cardiovascular diseases. Studies highlight the problems related to disturbed or excluded sleep due to bothersome unwanted noise. This demand for a quiet and sound indoor environment does not align with the constant urbanization taking place in society. One prevalent type of housing is a residence with an exterior corridor connecting the apartments. The common layout for these apartments is to place the bedroom directly adjacent to the corridor. Since the National Board of Housing, Building, and Planning (Boverket) imposes requirements for sound insulation between the corridor and the bedroom, it´s of relevance to investigate the impact of the floorplan to meet these required standards. This thesis aims to investigate any deviations in DnTw values with varying apartment layouts for calculated and field-measured values. The DnTw-value refers to sound insulation in an element, based on the reverberation in the receiving room. Further investigation is made to answer whether these potential deviations in field measurements correlate with the calculations made during the engineering process. The goal is to identify the differences between calculated and measured values for sound insulation and the effect of a varying floor plan. The results showed an insignificant difference in the measured DnTw value with varying volume. However, this deviation was different from the theoretically calculated difference between open and closed apartment layouts. Thus, the DnTw value is more prominently value dependent in theory compared to the values measured in the field. This leaves a higher DnTw value for the separating surface than the actual performance in the field.
7

Hampa som isoleringsmaterial : En studie av hampas isolerande egenskaper och materialets framtida möjligheter / Hemp as insulation material : A study of hemp´s insulating properties and the material´s future potential

Lundholm, Kelly, Hillerbratt, Emma January 2021 (has links)
Historically, energy use in the operational phase has accounted for most of a building’s climate impact. This has been changed in recent decades because there has been a focus on developing energy-efficient buildings. A larger part of a building’s climate impact is caused by material manufacturing and production. To reduce a building’s climate impact alternative insulation materials can be used, for example hemp fibre insulation which is an organic and non-toxic material. The aim of this study is to find out if hemp fibre insulation can be implemented as a standard insulation material. By examining what factors are vital when choosing an insulation material this work intends to find out if the insulation properties of hemp insulation can fulfill the requirements by the constructor. To fulfill the aim, a combination of interviews, surveys and theoretical studies was used. The most crucial aspects when choosing insulation material are fire resistance, thermal conductivity and health aspects for the construction workers. The benefits with hemp insulation are primarily the negative emissions of carbon dioxide seen from a life cycle perspective, the possibility to cultivate the product within Sweden, its reusability and recyclability and that the insulation material are free from hazardous substances. The disadvantages are higher thermal conductivity, higher market price, lower fire resistance and limited accessibility on the Swedish market. Due to the disadvantages, it is difficult to implement hemp insulation as a standard insulation material today. The conclusions are that the environmental impact is not decisive for an entrepreneur today when choosing insulation material. However, it will most likely become a more essential factor in the future. Improving the building sector’s knowledge regarding hemp insulation, will presumably increase the usage of it. Although, for hemp insulation to become a competitor in the future, it is substantial to increase its fire resistance and the accessibility on the Swedish market. The development of the material and the market may be a contributing factor to achieve the global and national environmental goals.
8

Träbjälklag med tung fyllning : Bjälklag framtaget med inspiration av byggteknik från sekelskiftet 1800–1900 / Timber floor with heavy filling : Floor developed with inspiration from building technique from the turn of the 19th century

Af Klintberg, Albin, Åkehag, Jonny January 2017 (has links)
Denna rapport utreder möjligheterna att använda restprodukter som ljudisolering i lägenhetsskiljande mellanbjälklag av trä med spännvidd 6 m. Ett steg mot att uppfylla Sveriges byggindustris nollvision för koldioxidutsläpp är att bygga mer i trä och att återanvända/återvinna restprodukter. Det svenska entreprenadföretaget Skanska har vid sina krossanläggningar ett överskott av material i form av bergkross 0 - 0,2 mm och krossad restbetong. I denna rapport har en prototyp av ett träbjälklag tagits fram med influenser från byggtekniken från sekelskiftet 1800–1900 med avseende på nyttjandet av tung fyllningsmassa som ljudisolering i träbjälklag. Den framtagna bjälklagsprototypen uppfyller de krav som ställts i BBR efter dimensionering enligt Eurokoderna med hänsyn till brand, hållfasthet, svikt och nedböjning. Enligt en simulering i SEAWood, ett verktyg för akustiksimulering som är under utveckling vid RISE Research Institutes of Sweden, uppfylls även kraven på ljudisolering, detta stöds av de analyser som gjorts av mätresultat från liknande bjälklag. Fyllningsmaterialets höga vikt medför att prototypen är ett lågfrekvent bjälklag, detta kombinerat med att simuleringen endast är en indikation på ljudisoleringsegenskaper gör att det kommer krävas praktiska tester för att fastställa prototypens ljudisolerande och dynamiska egenskaper. Den framtagna bjälklagsprototypen är lämplig att prefabricera tack vare en konstruktion med få ingående delar. Att prefabricera bjälklaget har utöver de ekonomiska fördelar det medför stora fördelar ur ett arbetsmiljöperspektiv och är även fördelaktigt ur fuktsynpunkt. För att uppskatta bjälklagets miljöpåverkan gjordes en enklare jämförelse med ett prefabricerat betongbjälklag som visade att utsläppen av koldioxidekvivalenter fram till bruksfasen var mer än dubbelt så stor för betongbjälklaget än för prototypbjälklaget. / This report investigates the possibilities of using residual products as sound insulation in apartment separating timber floors with a span of 6 m. One step towards meeting the Swedish construction industry's zero vision for carbon dioxide emissions is to build more using timber and to reuse/recycle residual products. The Swedish building contractor Skanska has at its quarries a surplus of material in the form of crushed rock of the 0 - 0.2 mm fraction and crushed residual concrete. In this report, a prototype of a timber floor has been produced with influences of construction technology from the turn of the 19 th century regarding the use of heavy filling as sound insulation in timber floors. The developed floor prototype complies with the requirements set in BBR after dimensioning according the Eurocodes regarding fire safety, strength, sagging and deflection. According to a simulation in SEAWood, a tool for acoustic simulation which is under development at RISE Research Institutes of Sweden the requirements for sound insulation are also met, which is supported by analyzes made by comparing with data on similar timber floors. The high mass of the filling material implies that the prototype is a low frequency floor, this in conjunction with the simulation only being an indication of sound insulation properties, it will require practical tests to determine the prototypes sound insulating and dynamic properties. The developed floor prototype is suitable for prefabrication thanks to a design with few components. Prefabrication of the floor has in addition to the economic benefits it brings great benefits from a working environment perspective and is also beneficial from a moisture point of view. To estimate the environmental impact of the timber flooring, a simple comparison was made with a prefabricated concrete floor which showed that carbon dioxide emissions up to the using phase were more than twice that of the concrete floor than for the prototype floor.
9

Utvärdering av standard EN 1793–6:2012 för att undersöka bullerskyddsskärmars effektivitet in-situ

Sjöberg, Andrea January 2018 (has links)
Bullerskyddsskärmar används för att reducera buller från väg- och spårtrafik. Syftet med examensarbetet var att utvärdera standard EN 1793–6:2012, en mätmetod för att undersöka bullerskyddsskärmars effektivitet in-situ med avseende på ljudisoleringen. I nuläget bestäms bullerskyddsskärmars effektivitet med laborationsmätningar i ett diffust ljudfält, som inte överensstämmer med det direkta ljudfält och den komplexitet som är in-situ. Till följd av det blir ofta laborationsmätningarna missvisande. Det finns även en okunskap kring håligheter/ läckage och hur det påverkar den akustiska prestandan, vilket gör att det emellanåt leder till brister i installationen av bullerskyddsskärmar och att enhetens ljudreducering inte stämmer överens med förväntningarna. Det finns således ett behov av att bestämma en bullerskyddsskärms befintliga prestanda in-situ för att säkerställa de krav som ställs i specifikationerna. EN 1793–6:2012 ansågs vara lämplig för ändamålet men fler mätningar behövs utföras för att kunna säkerställa resultaten och för att verifiera mätsystemet. Ljudisoleringen bestämdes som en funktion av frekvenser i tersband och var giltiga i frekvensområdet mellan 200 Hz till 5 kHz respektive 400 Hz till 5 kHz. De undersökta bullerskyddsskärmar var: en i laminerat och härdat glas med aluminiumpelare, en icke-homogen vegetationsskärm i stålram och en kombinerad bullerskyddsskärm i akrylglas med aluminiumprofiler. Resultaten jämfördes med laborationsmätningar och/eller simuleringar i Insul. Bullerskyddsskärmarna i glas gav högre värden på ljudisoleringen än i laborationsmätning, ett resultat som kan bero på skillnaderna mellan diffust ljudfält och direkt ljudfält. Komplexiteten i vegetationsskärmen gjorde resultaten svåra att analysera, men läckage förekom i de högre frekvenserna. Adrienne-fönstren behövde bli specifikt beräknade för samtliga impulssvar eftersom dimensionerna för bullerskyddsskärmarna inte överensstämde med vad som definieras i EN 1793–6:2012 för certifieringsändamål. I EN 1793–6:2012 omnämns inte heller markreflektion, som påverkar den filtrerade signalen. Vidare studier behövs för att filtrera bort dessa oönskade komponenter. / Road traffic noise devices, for example noise barriers, are used to reduce the noise from road traffic and trams. The purpose of this master thesis is to evaluate the standard EN 1793-6:2012, a test method for determining noise barriers efficiency in-situ. Currently, noise barriers efficiency is determined with laboratory measurements in a diffuse sound field, which does not reflect the direct sound field and the complexity that are in-situ. As a result, laboratory measurements are often misleading. Due to a lack of knowledge about leakage, there are sometimes defects caused in the installation of the noise barriers that adversely affect the acoustic properties. There is thus a need to determine the intrinsic parameters of a noise barrier in-situ to ensure the requirements set in the specifications. The new method described in EN 1793-6:2012 was considered useful for the purpose but it was found that more measurements need to be performed to ensure results and to verify the measurement system. The sound insulation was determined for three noise barriers where results are expressed as a function of frequency in one third octave band and were valid in the frequency range between 200 Hz to 5 kHz respective 400 Hz to 5 kHz. The noise barriers tested were: a barrier in laminated glass with metal posts, a non-homogeneous vegetation barrier in a steel frame and a combined barrier with acrylic glass and metal. The results were compared with laboratory measurements and/or simulations in Insul. The glass barriers showed higher values ​​of the sound insulation index than the laboratory measurements, perhaps due to the different sound fields. The complexity of the vegetation barrier made the results difficult to analyze, but leakage occurred in the higher frequencies. The Adrienne temporal windows were specifically calculated for all impulse responses, since the dimensions of the noise barriers differed from the one defined in EN 1793-6: 2012 for certification purposes. Also, in EN 1793-6: 2012, ground reflection, which affects the filtered signal, is not mentioned. Further studies are needed to filter out these unwanted components.
10

Läkande rum : - ett examensarbete om arkitektur, psykiatri och läkande miljöer / Curative Spaces : - a Book about Architecture, Psychiatry and healthy Environments and a Vision for Psychiatric Healthcare in the Future

Kallstenius, Marie-Louise January 2011 (has links)
Projektets syfte är att försöka utröna hur en visionär psykiatri skulle kunna se ut i framtiden. Jag frågade mig om man som arkitekt kan komma med en vision som är en lösning på psykiatrins problem. Hur gör man för att maximera de läkande faktorerna så att patienter återhämtar sig så fort och fullständigt som möjligt? Projektet är också ett försök att förmänskliga en av de stora insitutioner vi är beroende av i samhället och har resulterat i en bok i ämnet och ett designprojekt.

Page generated in 0.0795 seconds