• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 218
  • 20
  • 3
  • 1
  • Tagged with
  • 244
  • 85
  • 47
  • 38
  • 34
  • 33
  • 31
  • 31
  • 31
  • 27
  • 27
  • 26
  • 24
  • 24
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Efeito relaxante do estimulador da guanilato ciclase solúvel BAY 41-2272 em segmentos isolados de ureter humano em modelo padronizado in vitro / Relaxing effect of BAY 41-2272, a soluble guanylate cyclase stimulator, in isolated human ureter segments in a standardized in vitro model

Miyaoka, Ricardo, 1979- 08 May 2014 (has links)
Orientadores: Carlos Arturo Levi D'Ancona, Edson Antunes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-25T22:31:02Z (GMT). No. of bitstreams: 1 Miyaoka_Ricardo_D.pdf: 38810158 bytes, checksum: a73083863b9c18c44630b11b53472286 (MD5) Previous issue date: 2014 / Resumo: Introdução: A terapia medicamentosa expulsiva no tratamento da calculose ureteral visa abreviar o tempo para eliminação espontânea do cálculo e evitar a necessidade de uma intervenção cirúrgica. As terapêuticas atuais baseiam-se essencialmente em bloqueadores de canais de cálcio e bloqueadores alfa-adrenérgicos, mas têm eficácia questionável, conforme demonstram estudos clínicos mais recentes e com alto nível de evidência. Assim, faz-se necessária a investigação persistente de novos agentes para este fim. Objetivos: Descrever modelo padronizado de contratilidade ureteral in vitro com segmentos isolados de ureter humano a fim de avaliar o relaxamento provocado pelo estimulador da guanilato ciclase solúvel BAY 41-2272; avaliar o envolvimento da via do NO-GMPc-PDE5 e dos canais de potássio e urotélio neste processo; avaliar a expressão das enzimas guanilato ciclase solúvel (GCs), óxido nítrico sintase (NOS) e fosfodiesterase tipo 5 (PDE5) no ureter por meio de imunohistoquímica. Materiais e Métodos: Segmentos de ureter distal de 17 doadores falecidos de múltiplos órgãos de ambos sexos (24 ¿ 65 anos de idade, média 40 ± 3.2 anos; homens 2:1 mulheres) foram utilizados. A contratilidade ureteral foi avaliada em banho de solução de Krebs e o tecido pré-contraído com KCl 80nM . Os valores de potência foram determinados como o log negativo da concentração molar para induzir 50% do relaxamento máximo nos espécimes pré-contraídos com KCl. O teste não-pareado T de Student foi usado para as comparações. Resultados: O BAY 41-2272 produziu relaxamento em ureter isolado em tecidos pré-contraídos com KCl (80 mM) com valores de potência (pEC50) e relaxamento máximo (Emax) de 5,82 ± 0,12 (n=8) e 84 ± 5%, respectivamente. A adição do inibidor da sintase de óxido nítrico (L-NAME, 100 ?M, n=6) ou da guanilato ciclase solúvel (ODQ, 10 ?M, n=6) reduziu em, 21 e 44% (P<0,05) a Emax, respectivamente, sem alteração dos valores de pEC50. A pré-incubação do inibidor da PDE5, sildenafil (100 nM) potencializou (pEC50: 6,39 ± 0,10, n=8, P<0,05) o relaxamento induzido pelo BAY 41-2272 em comparação à curva controle. A adição dos bloqueadores inespecíficos de canais de potássio (glibenclamida) ou ATP-dependentes (tetraetilamônio ¿ TEA) e a ausência de urotélio não interferiram nos parâmetro farmacológicos do BAY 41-2272. A imunorreatividade mostrou a presença da eNOS no endotélio de estruturas vasculares do ureter e nNOS no urotélio, estruturas nervosas e, fracamente, na musculatura lisa. A GCs é expressa tanto no urotélio como na musculatura lisa. A PDE5 é expressa, exclusivamente, na musculatura lisa. Conclusão: O BAY 41-2272 provoca relaxamento em segmentos ureterais humanos pré-contraídos com KCl em modelo in vitro de forma concentração-dependente, essencialmente pela ativação da guanilato ciclase presente no músculo liso, e não no urotélio, apesar de um mecanismo GMPc-independente poder estar envolvido. Esta nova classe farmacológica pode ter papel no tratamento clínico de cálculos ureterais obstrutivos / Abstract: Introduction: Medical expulsive therapy in the treatment of ureteral calculi aims to reduce the timeframe for spontaneous stone expulsion avoiding an unwanted surgical intervention. Current clinical therapy is essentially based upon the use of calcium channel blockers and alpha-adrenergic antagonists which have been recently shown to offer questionable efficacy according to well-designed recent clinical trials with a high level of evidence. As such, it is necessary to continue the pursuit for new agents that could abbreviate the time for ureteral stone expulsion. Objectives: To report on a standardized ureteral contractility in vitro model with isolated human ureter segments in order to characterize the relaxation induced by soluble guanylate cyclase stimulator BAY 41-2272; to assess the involvement of NO-cGMP-PDE5 pathway and potassium channels in ureteral relaxation; to assess the immunohystochemical expression of endothelial (eNOS) and neuronal NO synthase (nNOS), soluble guanylate cyclase (sGC) and type 5 phosphodiesterase (IPDE5) in human ureter. Materials and Methods: Distal ureteral segments harvested from 17 multiple organs deceased donors (age 24-65; mean 40 ± 3.2; men/women ratio 2:1) were used. Ureteral contractility was assessed with segments immersed into Kreb¿s solution after being pre contracted with 80mM KCl. BAY 41-2272 induced ureteral relaxation in KCl pre contracted isolated segments with pEC50 and Emax of 5,82 ± 0,12 (n=8) and 84 ± 5%, respectively. Addition of a NOS inhibitor (L-NAME, 100 ?M, n=6) or soluble guanylate cyclase (ODQ, 10 ?M, n=6) led to a reduction of 21% and 44% in Emax values (P<0,05), respectively. pEC50 values remained unaltered. PDE5 inhibitor sildenafil (100 n M) enhanced (pEC50: 6,39 ± 0,10, n=8, P<0,05) the relaxing effect provoked by BAY 41-2272 compared with control curve. Neither unspecific potassium channel blockers glibenclamide nor ATP-dependent potassium channel blocker tetraethylammonium (TEA) nor ureteral urothelium removal influenced the relaxation response by BAY 41-2272. Immunochemistry markers showed eNOS expression in ureteral vascular endothelium, nNOS in urothelium, nerve structures and with less intensity in smooth muscle. Soluble guanylate cyclase was present in urothelium and smooth muscle; and PDE5 was only expressed in ureteral smooth muscle. Conclusions: BAY 41-2272 relaxes human isolated ureter segments in a concentration-dependent manner, mainly by activating the sGC enzyme in smooth muscle cells rather than in the urothelium, although a cyclic guanosine monophosphate-independent mechanism may exist. This pharmacological class may have a role in treating ureteral obstructive calculi / Doutorado / Fisiopatologia Cirúrgica / Doutor em Ciências da Cirurgia
122

Estudo experimental de teórico das constantes de acoplamento n ANTPOT. ('J IND. ch') (n= 1,2,3) em adamantanos substituídos / Experimental and theoretical study of n ANTPOT. ('J IND. ch') (n= 1,2,3) spin-spin coupling constants in substituted adamantane

Silva, Caio Ricardo Faiad da, 1987- 20 August 2018 (has links)
Orientador: Roberto Rittner Neto / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-20T02:42:28Z (GMT). No. of bitstreams: 1 Silva_CaioRicardoFaiadda_M.pdf: 3324014 bytes, checksum: 2a09da96b3179c4cc07eb8d6923bcdd1 (MD5) Previous issue date: 2011 / Resumo: A introdução da dissertação consiste na breve descrição da racionalização de acoplamentos JCH (n = 1, 2 e 3), das etapas de cálculos teóricos e das duas técnicas recentemente implementadas no IQ-Unicamp: HSQC-TOCSY-IPAP e IPAP-HSQMBC. A primeira parte da seção Resultados e Discussão trata da determinação experimental dos acoplamentos nos derivados de adamantano. Na parte que aborda as constantes calculadas é mostrado que não há necessidade de alto rigor teórico nos cálculos de otimização de geometria para moléculas rígidas em estudos de constante de acoplamento. As estruturas otimizadas nos níveis de teoria PM3 e B3LYP não apresentaram diferenças nos parâmetros geométricos e nem nas constantes de acoplamento teóricas. Sendo assim, o tempo para a obtenção dos resultados utilizando o método PM3 é drasticamente diminuído. A última parte dos Resultados e Discussão consiste na racionalização os JCH. A introdução do substituinte no adamantano não provoca modificação estrutural e por isso as variações das JCH são atribuídas às interações hiperconjugativas. O aumento do JCßHß para todos os derivados e devido a interação do substituinte com o sCC ou sCC*. Já para os JCaHb e JCaHg é observado que para os substituintes CN, C(O)CH3 e C(O)NH2 a interacao sCaCb n*CO ou sCaCb n*CN, que retira densidade eletrônica do caminho do acoplamento, não permitem que haja aumento nessas constantes. Para os demais substituintes as interações NXs*CaCb, que aumenta a densidade eletrônica do caminho do acoplamento, são os responsaveis pelo aumento desse acoplamento / Abstract: In the Introduction section, there are short descriptions of the: a) rationalization of spin-spin couplings JCH (n = 1, 2 e 3); b) the steps of theoretical calculations; and c) two NMR experiments recently implemented at IQ-UNICAMP: HSQC-TOCSY-IPAP and IPAP-HSQMBC. The first part of Results and Discussion approaches the experimental determination of the spin-spin coupling constants (SSCC) in adamantane derivatives. The second part approaches theoretical spin-spin coupling constants. In this part is shown that isn ft necessary high precision in theoretical calculations of geometry optimization for studies of spin-spin coupling constants in rigid molecules. The optimizated structures at PM3 and B3LYP level of theory present no difference geometrical parameters as well as the theoretical values of SSCC. The results lead a decrease in the computational efforts. The last part of Results and Discussion is about rationalization of JCH. The substituent in adamantane doesn ft cause structural changes, so the variations in JCH are attributed to hyperconjugation. The increase in JCßHß for all derivatives is due to interaction between substituent and C-C bond (sCC or sCC*). For the JCaHb and JCaHg is observed that for the CN, C(O)CH3 and C(O)NH2 substituents the interaction sCaCb n*CO ou sCaCb n*CN, which removes electronic density in coupling pathway, doesn ft allow no increase in these constants. For the others substituents interactions NXs*CaCb, which increases electronic density in coupling pathway, are responsible for the increase in these spin-spin coupling constants / Mestrado / Quimica Organica / Mestre em Química
123

Desenvolvimento de um programa computacional visando o estudo das tensões induzidas por descargas atmosfericas

Zago, Fernando 03 August 2018 (has links)
Orientador: Jose Pissolato Filho, Geraldo Peres Caixeta / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-03T22:26:34Z (GMT). No. of bitstreams: 1 Zago_Fernando_M.pdf: 1023949 bytes, checksum: a9e2ed41c92d7bd1c7195f2383431f75 (MD5) Previous issue date: 2004 / Mestrado
124

Estudos conformacionais pela espectroscopia no infravermelho e calculos teoricos de alguns compostos heterociclicos 2-substituidos / Infrared and theoretical investigation of conformational isomerism in some 2-substituted heterocyclic compounds

Mesquita, Alexandre Pinto 24 February 2005 (has links)
Orientador: Roberto Rittner / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-04T14:36:06Z (GMT). No. of bitstreams: 1 Mesquita_AlexandrePinto_M.pdf: 3953195 bytes, checksum: 418e539bcacd86a111fd5ab90fb668d9 (MD5) Previous issue date: 2005 / Mestrado / Quimica Organica / Mestre em Química
125

Estudio y Simulación de Sistemas Adaptables Fraccionarios Simples

Borries Segovia, Magdalena Andrea Von January 2012 (has links)
No description available.
126

Simulação computacional de descargas atmosfericas em estruturas de proteção visando analises de compatibilidade eletromagnetica

Caixeta, Geraldo Peres 24 April 2000 (has links)
Orientador: Jose Pissolato Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-31T17:20:27Z (GMT). No. of bitstreams: 1 Caixeta_GeraldoPeres_D.pdf: 2409891 bytes, checksum: a8425bfafab58cad646fe61ee714acfa (MD5) Previous issue date: 2000 / Resumo: Este trabalho apresenta o estudo da proteção contra descargas atmosféricas através da simulação computacional do transitório de corrente e do campo eletromagnético resultante. Foi necessário o desenvolvimento de uma nova expressão analítica de cálculo do campo eletromagnético (em coordenadas Cartesianas) devido à generalidade das possíveis configurações de uma estrutura. O processo de simulação é composto de quatro fases seqüenciais, as quais foram incluídas em um mesmo programa de computador, escrito em linguagem Fortran. Na primeira fase, a corrente de retomo de uma descarga atmosférica foi modelada como uma linha de transmissão disposta na vertical, ligando a fonte (nuvem) à terra (ou à uma estrutura de proteção). Na segunda fase, a estrutura de proteção foi modelada como sendo constituída de cabos interconectados em geometrias quaisquer, conectada ao canal do raio e á malha de aterramento. Na terceira fase, a malha de aterramento foi modelada também como sendo constituída de cabos interconectados. Na última fase, foi aplicada a expressão de cálculo do campo eletromagnético resultante do transitório de corrente de todo o processo mencionado. Na simulação da expressão de cálculo do campo, cada segmento dos cabos (ou linhas) foi considerado como um pequeno dipolo e o método das imagens foi adotado. A técnica TLM (Transmission Line Modelling) mostrou ser a melhor opção na simulação do transitório de corrente, uma vez que para cada cabo (considerado como urna linha de transmissão), foi possível adotar essa técnica em apenas uma dimensão. Este artificio não é possível em outras técnicas numéricas, como em diferenças finitas, em elementos finitos ou no método dos momentos, sendo nestes casos, necessária a discretização de todo o espaço, além de incorrer em problemas de condições de contorno. Na simulação do campo eletromagnético, foi adotada a técnica de diferenças finitas na nova expressão desenvolvida. Uma grande vantagem de se poder trabalhar com a expressão analítica, é o fato de não se ter que discretizar todo o espaço em volta do sistema simulado, podendo obter resultados de campos em pontos específicos do sistema de coordenadas Cartesianas / Abstract: This work presents the study of protection against lightning through current transitory coniputational simulation and electromagnetic field results. The development of a new ana1ytical expression of calculation for the electromagnetic field was necessary (in Cartesian coordinates) due to the generality of the possible configurations of a structure. The process of simulation is composed of four phases, which were included in the same computer program, written in the Fortran language. In the first phase, the lightning return current Was modeled as a transmission line arranged in the vertical axis, connecting the source (cloud) to the earth (or to a protection structure). In the second phase, the protection structure was modeled as cables interconnected in any geometry, connected to the lightning channel and then to the ground mesh. In the third phase, the ground mesh Was also modeled as interconnected cables. In the last phase, the electromagnetic field calcuIation expression of the transitory of current of the whole process mentioned Was applied. In the simulation of the expression of the field calculation each segment ofthe cables (or lines) was considered as small dipoles and the image method was adopted. Transmission Line Modeling TLM showed to be the best option in the current transitory simulation, once for each cable (considered as a transmission tine), which pennitted the adoption of that technique in one dimension. This artífice canoot be used in other numeric techniques, for example in the tinite differences method. In tinite elements, or the Moment method, the discretization of alI the space is necessary, although problems of contour conditions occur. In the simulation of the electromagnetic field, the tinite differences were adopted with a new developed expression. The advantage of this solution is to work with the analytical expressions and the fact oí not having to completely discretize the space around the simulated system / Doutorado / Engenharia Eletrica / Doutor em Engenharia Elétrica
127

Modelo experimental em suinos para comparação entre litotridores e estudo comparativo entre litotridor eletrohidraulico e eletromagnetico

Leitão, Victor Augusto Sanguinetti Scherrer 09 September 2009 (has links)
Orientador: Carlos Arturo Levi D'Ancona / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-14T10:41:25Z (GMT). No. of bitstreams: 1 Leitao_VictorAugustoSanguinettiScherrer.pdf: 1700258 bytes, checksum: 2379024277024619e3fd370dd428bf85 (MD5) Previous issue date: 2009 / Resumo: O tratamento da litíase urinária foi revolucionado em 1980 pelo desenvolvimento do litotridor extracorpóreo, capaz de fragmentar cálculos por meio de ondas acústicas. Inicialmente, a litotripsia extracorpórea por ondas de choque foi vista como a solução para todos os pacientes com cálculos urinários, porém o tempo provou que existem limitações e que a evolução dos aparelhos não melhorou a taxa de fragmentação. Geradores mais modernos não produzem resultados comparáveis àqueles do Dornier HM3®, o primeiro litotridor eletrohidráulico, com aumento nas taxas de re-tratamento. O objetivo deste estudo foi descrever um modelo experimental in vivo de litotripsia e comparar a um equipamento eletromagnético, o Siemens Modularis®, com o HM3, considerado o "padrão ouro". Doze suínos fêmeas (n=24 rins), com peso médio de 36 kg (34- 38 kg), foram separados em grupos de três animais, de acordo com o equipamento e o número de choques aplicados (eletrohidráulico: EH500 e EH2000, eletromagnético: EM500 e EM2000). Os animais foram submetidos a laparotomia mediana e ureterotomia proximal para implante de cálculos artificiais de BegoStone Plus® em ambos os rins. Os cálculos mediam 10x5 mm, com peso médio de 0,452 g (0,439 - 0,464 g). O HM3® original foi utilizado com 20 quilovolts, sendo usado um eletrodo novo para cada rim. O litotridor Modularis® utilizou nível de energia 4.0 e para acoplamento foi usado gel acústico. Após a litotripsia, os animais foram sacrificados e os rins abertos para remoção dos fragmentos. A ausência de fragmentos residuais foi confirmada por radiografia. Os fragmentos foram separados, com o auxílio de peneiras geológicas, conforme o tamanho em: maiores que 4,0 mm; entre 2,8mm e 4 mm; entre 2,0mm e 2,8 mm e menores que 2,0 mm. A eficiência do aparelho foi definida pela soma da massa de fragmentos que passaram pela peneira de 2,0 mm somada à massa dos fragmentos não recuperados. Após 500 choques o HM3 foi mais eficiente (p=0,012). Após 2000 choques o HM3 obteve melhor fragmentação sem, contudo, alcançar diferença estatística (p=0,206). Foi excluído de cada grupo o cálculo com a menor massa de fragmentos <2mm e refeita a análise com cinco amostra por grupo. O HM3 apresentou melhores resultados tanto após 500 como após 2000 choques (p=0,008 e p=0,072, respectivamente). O HM3 possui vantagens de acoplamento ideal devido à imersão em água, assim como ponto focal (F2) aleatório e aumento progressivo da distância entre os pólos do eletrodo, que são características intrínsecas ao equipamento eletrohidráulico. Essas qualidades fazem do HM3 um aparelho mais eficiente. O método in vivo descrito é factível e consistente, revelando a superioridade do Dornier HM3® quando comparado ao Siemens Modularis®. / Abstract: Urinary stone treatment was revolutionized in 1980 by the development of extracorporeal lithotripter, which is capable of stone comminution by means of acoustic waves. Initially, extracorporeal shock wave lithotripsy (ESWL) was seen as the solution for all stone patients, but time has proved that there are limitations and that lithotripter evolution did not increase fragmentation rates. Modern generations of lithotripter did not produce comparable results to the Dornier HM3, the first electrohydraulic lithotripter, with an increase in re-treatment rates. The objective of this study was to describe an experimental model of in vivo lithotripsy and compare an electromagnetic device (Siemens Modularis) to the electrohydraulic HM3, considered the gold standard. Twelve female swines (n=24 kidneys) weighing on average 36 kg (34- 38 kg) underwent midline laparotomy and proximal ureterotomy for implantation of BegoStone Plus artificial stones in both kidneys. Stones measured 10 x 5 mm and weighed on average 0.452 (0.439 - 0.464 g). An original HM3 was set on 20kV and a new electrode used for each kidney. Modularis was set on energy level 4.0 and water based gel used as coupling agent. Upon treatment completion animals were euthanized and kidneys removed for fragment collection. Complete removal of fragments was confirmed by radiography. Fragments were then separated according to size (>4 mm, 2.8 - 4.0 mm, 2.0 - 2.8 mm, and <2.0 mm) using brass geological sieves. Efficiency was defined as the sum of fragment mass passing the 2 mm mash and those not recovered. After 500 shocks the HM3 had higher efficiency (p=0.012). At 2000 shocks HM3 had better comminution results, although statistical significance was not achieved (p=0.206). After exclusion of the calculus with the least mass of fragments <2mm for each group, HM3 presented better results than Modularis both after 500 and 2000 shocks (p=0.008 and 0.072, respectively). The HM3 has the advantages of ideal coupling, utilizing a water tub, as well as random focal point and spark gap increase, which are intrinsic to the electrohydraulic equipment These characteristics make the HM3 a more efficient lithotripter. The in vivo method described is feasible and consistent, revealing the superiority of HM3 when compared to the Siemens Modularis. / Universidade Estadual de Campi / Cirurgia / Doutor em Cirurgia
128

Uma contribuição para o calculo do campo eletrico em cabos trifasicos

Delgado Leon, Miguel Zacarias 18 August 1995 (has links)
Orientador: Carlos Alberto Favarin Murari / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-20T14:44:33Z (GMT). No. of bitstreams: 1 DelgadoLeon_MiguelZacarias_M.pdf: 3172693 bytes, checksum: edf12be10549e3953144c55f55aaa26d (MD5) Previous issue date: 1995 / Resumo: Baseado no Principio da Superposição, este trabalho apresenta um método eficiente para calcular o campo elétrico para qualquer o campo elétrico em cabos de potencia trifásicos. O problema do campo elétrico para qualquer condição normal de tensão ('V IND. A¿, 'V IND. B¿, 'V IND. C¿) nas três fases dos condutores, é reduzido ao cálculo do campo elétrico para uma nova condição básica de tensão nos condutores, isto é, 'V IND. A¿ = 0, 'V IND. B¿ = ', 'V IND. C = '. O Método de Simulação de Carga é utilizado é utilizado para representar a condição (0,1, - 1) nos condutores. ... Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
129

Etiologia da pancreatite aguda - revisão sistemática e metanálise

Zilio, Mariana Blanck January 2018 (has links)
Introdução: A litíase biliar e o consumo de álcool são as etiologias mais frequentes para pancreatite aguda (PA), sendo reportadas como responsáveis por cerca de 40 e 30% dos casos respectivamente. No entanto, no Rio Grande do Sul - BR observamos uma frequência de pancreatite aguda biliar (PAB) em torno de 77% dos casos e pancreatite aguda alcoólica (PAA) em apenas 8%. Além da possibilidade de diferenças próprias da nossa população, é possível que a incidência de PAB esteja aumentando. Objetivo: Estimar as frequências globais da PAB, PAA e dos casos considerados pancreatite aguda idiopática (PAI) em estudos publicados de 2006 a 18 de outubro de 2017. Comparar as frequências de PAB, PAA e PAI entre os estudos que realizaram revisão de prontuários individuais dos pacientes ou foram prospectivos e os que utilizaram apenas os códigos de alta hospitalar para o diagnóstico etiológico. Comparar as frequências de PAB, PAA, PAI de acordo com região geográfica da população dos estudos. Métodos: Uma revisão sistemática de estudos observacionais em Inglês, Espanhol e Português, de 2006 a 18 de outubro de 2017 foi realizada. Metanálise pelo modelo de efeitos randômicos foi utilizada para calcular as frequências de PAB, PAA e PAI globais e nos subgrupos (diagnóstico por código da alta hospitalar, diagnóstico por avaliação individualizada do prontuário do paciente, estudos dos EUA, estudos da América Latina, estudos da Europa e estudos da Ásia). Resultado: Foram incluídos quarenta e seis estudos representando 2.341.007 casos de PA em 36 países. A estimativa global para a pancreatite aguda biliar (PAB) foi 41,6% (IC 95% 39,2-44,1), seguido por PA alcoólica (PAA) com 20,5% (IC 95% 3 16,6-24,6) e PA idiopática (PAI) em 18,3% (IC 95% 15.1 - 21,7). Em estudos com diagnóstico etiológico por código de alta a PAI foi a mais frequente com 37,9% dos casos (IC 95% 35,1 - 40,8). Nos estudos que revisaram os prontuários dos pacientes a PAB foi a mais frequente com 46% (IC 95% 42,3 - 49,8). Nos EUA a PAI foi a mais frequente com 34,7% (IC 95% 32,3 - 37,2). Na América Latina a estimativa de PAB foi de 68,5% (IC de 95% 57,8 - 78,3). Na Europa, na Ásia e em 1 estudo Australiano, a etiologia mais frequente foi a PAB em 41,3% (IC 95% 37,9 - 44,7), 42% (IC 95% 28,8 - 55,8) e 40% (IC 95% 36,8 - 43,2), respectivamente. Na África do Sul 1 artigo apresentou frequência de 70,2% (IC de 95% 64,5 - 75,4) para PAA. Conclusão: A PAB é a etiologia mais prevalente da PA, sendo 2 vezes mais frequente que o segundo lugar. A América Latina apresenta uma frequência para PAB muito maior do que o resto do mundo. Grandes estudos populacionais que utilizam diagnósticos codificados e estudos americanos apresentam elevadas taxas de PA sem classificação. A importância do diagnóstico etiológico consiste no tratamento da causa para prevenção da recorrência. / Background: Gallstones and alcohol are the most common etiology of acute pancreatitis (AP) and is reported to account for about 40% and 30% of cases respectively. However, in Rio Grande do Sul - BR, we observed a frequency of acute biliary pancreatitis (ABP) around 77% of cases and alcoholic acute pancreatitis (AAP) in only 8%. Besides the possibility of differences of our own population, it is possible that the incidence of PAB is increasing. Objective: estimate the global frequency of ABP, AAP and the cases considered idiopathic pancreatitis (IAP) in published studies from 2006 to October 18 2017. Compare the frequencies for ABP, AAP and AIP among studies that performed review of individual records of patients or collected data prospectively and those using only the hospital discharge diagnostic codes for etiologic diagnosis. Compare the frequency of ABP, AAP and IAP by geographic region. Methods: A systematic review of observational studies in English, Spanish and Portuguese, from 2006 to October 18, 2017 was done. Random-effects metaanalysis was used to assess the frequency of biliary, alcoholic and idiopathic AP worldwide and to perform the analysis of 6 subgroups (hospital discharge coded diagnosis, individual patient chart review, studies from US, Latin America, Europe and studies from Asia). Results: Forty-six studies were included representing 2.341.007 cases of PA in 36 countries. The overall estimate for ABP was 41.6% (95% CI 39.2 to 44.1), followed by AAP with 20.5% (95% CI 16.6 to 24 6) and IAP with 18.3% (95% CI 15.1 - 21.7). In studies with hospital discharge coded diagnosis IAP was the most frequent with 37.9% (95% CI 35.1 to 40.8). In studies with individual patient chart review PAB 5 was more frequent with 46% (95% CI 42.3 to 49.8). In US studies IAP was he most frequent etiology with 34.7% (95% CI 32.3 to 37.2). In Latin America PAB was estimated 68.5% of the cases (95% CI 57.8 to 78.3). In Europe, Asia and one Australian study, the most frequent cause was the ABP in 41.3% (95% CI 37.9 to 44.7), 42% (95% CI 28.8 to 55.8) and 40% (95% CI 36.8 to 43.2) of the cases respectively. One study from South Africa had AAP in 70.2% (95% CI 64.5 to 75.4) of the cases. Conclusion: Gallstones are the main etiology of AP globally, twice as frequent as the second one. Latin America has a frequency for ABP much higher than the rest of the world. Large population studies using coded diagnoses and American studies show high rates IAP. The importance of the etiological diagnosis resides in treating the cause in order to prevent recurrence.
130

CATALIZADORES MONO- Y MULTI-FUNCIONALES BASADOS EN NANOPARTÍCULAS METÁLICAS EN INTENSIFICACIÓN DE PROCESOS QUÍMICOS Y NUEVOS MEDIOS DE REACCIÓN COMPATIBLES CON LA QUÍMICA VERDE

Ródenas Torralba, Tania 04 July 2011 (has links)
La presente tesis doctoral se ha centrado en el diseño y la preparación de catalizadores mono- y multi-funcionales basados en nanopartículas metálicas (NPMs) empleando diferentes estrategias de síntesis. Estas NPMs se han estabilizado sobre diferentes superficies de materiales porosos de carácter básico y en medios de reacción alternativos de naturaleza iónica, funcionando en ambos casos como catalizadores eficientes en reacciones de interés. Una primera serie de NPMs se ha estabilizado en medios líquidos iónicos derivados del catión imidazolio, los cuales han proporcionado además un medio de reacción alternativo a los disolventes clásicos convencionales. En este medio de reacción se ha llevado a cabo la reacción de ciclopropanación de alquenos utilizando diazoacetato de etilo (EDA) como fuente de iones carbeno y se ha estudiado la influencia del tamaño de nanopartícula y del anión en la actividad y selectividad del catalizador. Una segunda serie de NPMs se ha estabilizado sobre superficies de sólidos básicos empleando técnicas de impregnación, coprecipitación, deposición y métodos sol-gel, los cuales han permitido obtener una elevada dispersión metálica y un tamaño óptimo en el rango de la nanoescala. Estos materiales se han aplicado en intensificación de procesos químicos llevando a cabo diferentes tipos de transformaciones secuenciales o reacciones en cascada, basados en la metodología de transferencia de hidrógeno, para la formación de enlaces C-N y C-C: a) monoalquilación de aminas con alcoholes y b) monoalquilación de sustratos metilénicos (benzonitrilo, nitrometano y malonado de dietilo) con alcoholes. En ambos casos, se han empleado ensayos cinéticos y técnicas espectroscópicas de caracterización in situ y operando para determinar el mecanismo de reacción. En el último capítulo se ha abordado el estudio de una de las etapas clave en el proceso de monoalquilación, la deshidrogenación de alcohol a aldehído catalizada por un metal. Comparando las energías de adsorción del alcohol y las barreras de activación, calculadas mediante la teoría DFT, con los valores obtenidos partir de experimentos cinéticos, junto con el análisis de la variación del TOF con respecto a número de átomos superficiales en las diferentes muestras, se puede concluir finalmente que la deshidrogenación oxidativa de alcoholes a compuestos carbonilo es sensible a la estructura y que la actividad de los centros accesibles de los átomos de oro es heterogénea y varía con el número de coordinación. / Ródenas Torralba, T. (2011). CATALIZADORES MONO- Y MULTI-FUNCIONALES BASADOS EN NANOPARTÍCULAS METÁLICAS EN INTENSIFICACIÓN DE PROCESOS QUÍMICOS Y NUEVOS MEDIOS DE REACCIÓN COMPATIBLES CON LA QUÍMICA VERDE [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/11109 / Palancia

Page generated in 0.0421 seconds