• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • 1
  • 1
  • Tagged with
  • 45
  • 15
  • 10
  • 8
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Hybrid pigments from fibrous clays and chromophores inspired by the color of fruits, flowers and wine / Pigmentos híbridos a partir de argilas fibrosas e cromóforos inspirados nas cores de frutas, flores e vinhos

Silva, Gustavo Thalmer de Medeiros 05 June 2019 (has links)
Features such as color, brightness, fluorescence and stability are extremely important in applications of pigments. Anthocyanins, the natural pigment responsible for most of the purple, blue and red colors of flowers and fruits, have great potential for practical applications as dyes or antioxidants. However, these applications are limited by their chemical reactivity, which is affected by several factors, including pH, temperature, light, and oxygen, among others. Hybrid materials inspired by the ancient Maya Blue pigment are a promising alternative to improve the properties and applicability of natural and synthetic dyes. Flavylium cations serve as models for the chemical and photochemical reactivity of anthocyanins. Likewise, pyranoflavylium cations serve as models of the fundamental chromophoric moiety of pyranoanthocyanins, molecules that can form from reactions of the grape anthocyanins in red wines during their maturation. Fibrous clays, constituents responsible by the excellent stability of Maya blue pigment, have channels that can potentially allow partial or full insertion of these dyes molecules. Therefore, in the present thesis, hybrid pigments were prepared by the adsorption of a series of synthetic flavylium cations and synthetic pyranoflavylium cations on the fibrous clays palygorskite and sepiolite and their photophysical properties and stability were evaluated. The observation of biexponential fluorescence decays is consistent with emission from dye molecules adsorbed at two distinct sites on the fibrous clays. The fluorescence properties of dye molecules can be improved, depending on the amount of dyes adsorbed on the clay, by the formation of dye/clay hybrids. The color of the adsorbed dye molecules wassomewhat more resistant to changes in external pH, photochemical stability was maintained and the thermal lability was markedly improved. Besides the development of novel hybrid flavylium cation/fibrous clay, we have achieved advances in the stabilization of these dye molecules, with regard mainly to the pH-dependent equilibrium and thermal treatment. In addition, the present work represents the first systematic study of hybrid materials prepared from pyranoflavylium cations. Therefore, the results obtained here definitively point to flavylium cations and pyranoflavylium cations as promising chromophores and fibrous clays as promising substrates for the development of novel, highly fluorescent hybrid pigments with attractive colors and marked chemical and thermal stability. / Características como cor, brilho, fluorescência e estabilidade são extremamente importantes em aplicações de pigmentos. As antocianinas, os pigmentos naturais responsáveis pela maioria das cores púrpura, azul e vermelha das flores e frutas, têm grande potencial para aplicações práticas como corantes ou antioxidantes. No entanto, estas aplicações são limitadas pela sua reatividade química, que é afetada por diversos fatores, incluindo o pH, temperatura, luz e oxigênio, entre outros. Os materiais híbridos inspirados no antigo pigmento Maya Blue são uma alternativa promissora para melhorar as propriedades e a aplicabilidade dos corantes naturais e sintéticos. Os cátions flavílios servem como modelos para a reatividade química e fotoquímica das antocianinas. Da mesma forma, os cátions piranoflavílios servem como modelos do cromóforo fundamental das piranoantocianinas, moléculas que podem se formar a partir de reações das antocianinas das uvas em vinhos tintos durante sua maturação. Argilas fibrosas, constituintes responsáveis pela excelente estabilidade do pigmento Azul Maia, possuem canais que podem potencialmente permitir a inserção parcial ou total dessas moléculas corantes. Portanto, na presente tese, pigmentos híbridos foram preparados pela adsorção de uma série de cátions flavílio e piranoflavílio sintéticos nas argilas fibrosas paligorsquita e sepiolita e suas propriedades fotofísicas e estabilidade foram avaliadas. A observação de decaimentos biexponenciais de fluorescência é condizente com a emissãode moléculas do corante adsorvidas em dois sítios distintos nas argilas fibrosas. As propriedades de fluorescência das moléculas de corante podem ser melhoradas, dependendo da quantidade de corante adsorvida na argila, aos híbridos do tipo corante/argila. A cor das moléculas de corante adsorvidas foi um pouco mais resistente a alterações no pH externo, a estabilidade fotoquímica foi mantida e a labilidade térmica foi marcadamente melhorada. Além do desenvolvimento de novos híbridos de cátions flavílios/argilas fibrosas, obtivemos avanços na estabilização dessas moléculas corantes, principalmente no que diz respeito aos equilíbrios dependentes do pH e ao tratamento térmico. Ao mesmo tempo, o presente trabalho representa o primeiro estudo sistemático de materiais híbridos preparados a partir de cátions piranoflavílios. Portanto, os resultados aqui obtidos apontam definitivamente para cátions flavílios e cátions piranoflavílios como cromóforos promissores e argilas fibrosas como substratos promissores para o desenvolvimento de novos pigmentos híbridos altamente fluorescentes com cores atrativas e estabilidade química e térmica marcante.
22

Sobre a interação em circuito aberto entre metanol ou etanol e superfícies oxidadas de paládio / On the open circuit interaction between methanol or ethanol and palladium oxidized surfaces

Salmazo, Débora Heloisa Capella 03 December 2013 (has links)
Um dos problemas que contribui para a diminuição do desempenho de células a combustível de membrana trocadora de prótons é o cruzamento de combustível do compartimento anódico para o catódico. Um método de avaliar o contato do combustível anódico com o cátodo consiste da exposição do catalisador oxidado à molécula de interesse, em condições de circuito aberto. Do ponto de vista fundamental, a análise desses transientes de circuito aberto pode fornecer informações importantes acerca do mecanismo reacional associado. São apresentados nessa Dissertação, resultados da interação entre metanol ou etanol e superfícies oxidadas de paládio, em meio alcalino. Entre os parâmetros investigados, maior ênfase foi dada ao efeito da natureza do cátion alcalino presente no eletrólito. Observou-se que a presença de Li+ ou K+ no eletrólito influencia desde a quantidade de óxido formada, até o tempo requerido para a redução desses óxidos pela molécula orgânico dissolvida. A natureza do composto orgânico presente também exerce diferenças consideráveis no transiente de circuito aberto. Finalmente, foram propostos esquemas reacionais para representar a interação de circuito aberto com o metanol e etanol. Em ambos os casos, os mecanismos incluem a produção auto-catalítica de sítios livres de paládio. / One of the problems that contributes to the performance decreasing observed in proton exchange membranes is the fuel crossover from the anodic to the cathodic compartment. A method to evaluate the contact of the anodic fuel with the cathode consists of exposing the oxidized catalyst to the molecule of interest under open circuit conditions. From the fundamental point of view, the analysis of the open circuit transients may provide relevant information on the associated reaction mechanism. In this Dissertation, results of the open circuit interaction between methanol or ethanol with oxidized palladium surfaces, in alkaline media, are presented. Among the distinct investigated parameters, emphasis will be put on the effect of the nature of the alkali cation present in the electrolyte. It was observed that the presence of Li+ or K+ influences several aspects, from the amount of oxide formed to the time needed for the reduction of the oxide by the dissolved organic molecules. The identity of the dissolved organic molecule also exerts marked influence on the open circuit transients. Finally, two reaction schemes for the open circuit interaction with methanol or ethanol were proposed. In both cases, the mechanisms include the auto-catalytic production of free palladium sites.
23

Deposição atmosférica de espécies químicas em Ribeirão Preto, uma importante cidade canavieira do estado de São Paulo / Deposição atmosférica de espécies químicas em Ribeirão Preto, uma importante cidade canavieira do estado de São Paulo

Coelho, Cidelmara Helena 30 March 2007 (has links)
Amostras de água de chuva foram coletadas no campus da USP Ribeirão Preto (RP) de agosto de 2002 a dezembro de 2005. Cerca de 84% (n=127) das amostras apresentaram excesso de acidez, com pH médio de 5,12. Não se observou sazonalidade no pH de acordo com o período de safra da cana. As concentrações médias ponderadas pelo volume (MPV, em mol L-1): K+ 3,9 (n=175), Na+ 2,1 (n=172), Ca2+ 5,0 (n=175) e Mg2+ 1,8 (n=168), observadas em RP, bem como seus fluxos de deposição por via úmida, foram ligeiramente mais elevadas que aquelas encontradas em chuvas de regiões com características semelhantes. As concentrações destes cátions foram sazonais, com um aumento no período de safra, sendo que a maior diferença foi observada para o íon K+, indicando a sua importante fonte na queima de biomassa. A sazonalidade do íon Ca2+ aponta para a importância das atividades agrícolas, intensificadas no período de safra, na emissão deste cátion para a atmosfera. Observaram-se boas correlações lineares entre as concentrações de Na+ e K+ (0,67626) e de Na+ e Ca2+ (0,77822), indicando a possibilidade de emissões pirogênicas e a ressuspensão do solo serem fontes de emissão de Na+. A MPV de carbono orgânico dissolvido (COD) encontrada em RP foi mais elevada que na Amazônia, onde também há intensa queima de biomassa, porém seus fluxos por via úmida em ambas as regiões foram similares (0,42 molCm-2ano-1). As concentrações de COD em RP apresentaram correlações lineares significativas com K+ (0,70341) e com Ca2+ (0,61638), apontando para a queima de biomassa e ressuspensão do solo como fontes importantes de emissão de carbono orgânico para a atmosfera. As concentrações de COD nas chuvas de Araraquara foram ainda maiores que em RP, indicando pronunciadas fontes locais naquela cidade. As MPV (nmol L-1) de Cd 0,54 (n=56), Pb 3,02 (n=94) e Cu, 19,9 (n=98), encontradas nas chuvas de RP foram semelhantes a regiões urbanas e industriais do hemisfério norte, enquanto a concentração de Al (448 nmol L-1, n=126) foi menor, e a de Zn (405 nmol L-1, n=120) apresentou-se dentro das faixas de concentrações relatadas nestes locais. Com exceção de Cd, os demais metais analisados (Pb, Cu, Zn e Al) também apresentaram concentrações significativamente maiores (P=0,05) nas chuvas durante o período de safra, indicando que a queima de biomassa e as atividades agrícolas podem aumentar a emissão destes metais para a atmosfera de RP. A correlação linear significativa entre Pb e Ca2+ (0,53845), indica a participação da ressuspensão do solo no aporte atmosférico de Pb em RP, enquanto a ausência de correlação linear entre Zn e K+ (0,20182) parece indicar a presença de outras fontes significativas de Zn para a atmosfera de RP, além da queima de biomassa. O cálculo do fator de enriquecimento demonstra que Cd, Zn, Pb e Cu estão enriquecidos com relação ao solo na chuva de RP, sugerindo que estes podem ter fontes antrópicas locais e / ou distantes. A análise preliminar de componentes principais não esclareceu o peso das diferentes fontes de emissão atribuídas neste trabalho. / Rain water samples were collected based on events at the University of São Paulo - campus Ribeirão Preto - from August 2002 to December 2005. About 84% (n=127) of the samples had excess of acidity, with an average pH of 5.12. There was no correlation between the pH values and the sugar cane harvest period. The Volume Weighed Means (VWM, in mol L-1) for K+ 3.9 (n=175), Na+ 2.1 (n=172), Ca2+ 5.0 (n=175) and Mg2+ 1.8 (n=168), and their wet fluxes in RP were slightly higher than those reported to regions with similar characteristics. The concentrations for these cations were seasonal, with higher values during the harvest period. The largest difference was observed for K+, indicating its important source in the biomass burning activity. The seasonality showed for Ca2+ is probably related to the higher soil resuspension during the more intense agricultural activities. A good linear correlation observed between Na+ and K+ (0.67626) and between Na+ and Ca2+ (0.77822), suggest that Na+ may have important pirogenic as well as soil dust sources. The VWM for Dissolved Organic Carbon (DOC) in RP was higher than that reported for rainwater in the Amazon region (where the biomass burning is also intense); however, the wet fluxes from both sites were very similar (0.42 mol C m-2 ano-1). DOC concentrations were well correlated with K+ (0.70341) and Ca2+ (0.61638), suggesting that the biomass burning as well as soil dust can be important sources of organic carbon to the atmosphere. DOC concentrations in rainwater from Araraquara were even higher than those for RP, showing a high local source of organic carbon. The VWM (nmol L-1) for Cd 0.54 (n=56), Pb 3.02 (n=94) and Cu 19.9 (n=98) found in the rainwater from RP were similar to urban and industrialized regions of the Northern Hemisphere, while for Al (448 nmol L-1, n=126) it was lower, and for Zn (405 nmol L-1, n=120) the VWM was within the range reported for such areas. Except for Cd, all the other metals measured (Pb, Cu, Zn and Al) also showed higher concentrations (P=0.05) in rainwater samples during the harvest period, suggesting that biomass burning and intensive agricultural activities can increase these species concentrations in the atmosphere. The significant linear correlation between Pb and Ca2+ (0.53845) indicates that soil inputs can be of relevance for Pb atmospheric inputs in RP. On the other hand, the absence of linear correlation between Zn and K+ (0.20182) seems to indicate the presence of other important sources for Zn to the atmosphere besides biomass burning. The calculated Enrichment Factor showed that Cd, Zn, Pb and Cu are anomalously enriched in RP rainwater in relation to soil, suggesting these metals may have antroprogenic local sources as well as distant ones. The preliminary statistical analysis of principal components did not clarify the weight of the different sources of emission attributed in this work.
24

Sobre a interação em circuito aberto entre metanol ou etanol e superfícies oxidadas de paládio / On the open circuit interaction between methanol or ethanol and palladium oxidized surfaces

Débora Heloisa Capella Salmazo 03 December 2013 (has links)
Um dos problemas que contribui para a diminuição do desempenho de células a combustível de membrana trocadora de prótons é o cruzamento de combustível do compartimento anódico para o catódico. Um método de avaliar o contato do combustível anódico com o cátodo consiste da exposição do catalisador oxidado à molécula de interesse, em condições de circuito aberto. Do ponto de vista fundamental, a análise desses transientes de circuito aberto pode fornecer informações importantes acerca do mecanismo reacional associado. São apresentados nessa Dissertação, resultados da interação entre metanol ou etanol e superfícies oxidadas de paládio, em meio alcalino. Entre os parâmetros investigados, maior ênfase foi dada ao efeito da natureza do cátion alcalino presente no eletrólito. Observou-se que a presença de Li+ ou K+ no eletrólito influencia desde a quantidade de óxido formada, até o tempo requerido para a redução desses óxidos pela molécula orgânico dissolvida. A natureza do composto orgânico presente também exerce diferenças consideráveis no transiente de circuito aberto. Finalmente, foram propostos esquemas reacionais para representar a interação de circuito aberto com o metanol e etanol. Em ambos os casos, os mecanismos incluem a produção auto-catalítica de sítios livres de paládio. / One of the problems that contributes to the performance decreasing observed in proton exchange membranes is the fuel crossover from the anodic to the cathodic compartment. A method to evaluate the contact of the anodic fuel with the cathode consists of exposing the oxidized catalyst to the molecule of interest under open circuit conditions. From the fundamental point of view, the analysis of the open circuit transients may provide relevant information on the associated reaction mechanism. In this Dissertation, results of the open circuit interaction between methanol or ethanol with oxidized palladium surfaces, in alkaline media, are presented. Among the distinct investigated parameters, emphasis will be put on the effect of the nature of the alkali cation present in the electrolyte. It was observed that the presence of Li+ or K+ influences several aspects, from the amount of oxide formed to the time needed for the reduction of the oxide by the dissolved organic molecules. The identity of the dissolved organic molecule also exerts marked influence on the open circuit transients. Finally, two reaction schemes for the open circuit interaction with methanol or ethanol were proposed. In both cases, the mechanisms include the auto-catalytic production of free palladium sites.
25

DIAGNÓSTICO DA FERTILIDADE DO SOLO DE ÁREAS EM IMPLANTAÇÃO DE AGRICULTURA DE PRECISÃO NO RIO GRANDE DO SUL / DIAGNOSTIC OF FERTILITY OF SOIL IN AREAS OF INSTALLATION OF PRECISION AGRICULTURE PROGRAM IN RIO GRANDE DO SUL STATE

Dias, Rodrigo Franco 02 September 2013 (has links)
This study sought to describe the current state fertility levels by analyzing 105,342 soil samples from different regions of the state of Rio Grande do Sul assigned by CCGL Technology. Thus, about 42% of the samples need to correct soil acidity. Phosphorus was the element that needs more attention in the soil correction. Potassium is present in most samples above the critical level suggesting a poor response to application in current models. Correction sulfur has potential response to crop yields in soya. In a second step, we used the data to study the balance of nutrients in the soil. The data were normalized and CTCpH7,0 was the parameter of soil divided into classes considering the normal distribution with a standard deviation for each class. The results showed that the base saturation to achieve the desired pH varied according to CTCpH7,0v soil. Soils with low CTCpH7,0 present trend lower percentage base saturation than a soil with CTCpH7,0 high. It was also found that the CTCpH7,0 soil influences the availability of the potassium equilibrium saturation. Soils with higher CTCpH7,0 require larger amounts of potassium to reach the critical level of 3% CTCpH7,0. The next step was to correlate the levels of elements in the soil and its relation to the levels shown by leaf analysis. For that were conducted soil sampling in grid 2 ha in an area in the municipality of Cachoeira do Sul, RS. This area was located soybean and collected samples of leaves and plants when they were in the flowering stage in the same spots where they were taken soil samples. Reading was also performed with the equipment GreenSeeker order to correlate them with samples of soil and leaves.The CTCpH7,0 soil, directly influences the availability of potassium in equilibrium saturation. Soils with higher cation exchange capacity tend to require larger amounts of potassium to reach the critical level of 3% of CTCpH7,0. The results of tissue samples of whole plants soybean correlate with the levels of potassium in the soil and its percentage in CTCpH7,0. Nevertheless the use of the analysis of the 3rd trifoliate leaf from flowering as a parameter for recommendation requires further study, as the results do not make clear the relationships between these elements in the leaves and in the soil. / A agricultura de precisão vem se consolidando como uma técnica para melhoria dos níveis de fertilidade do solo. Inicialmente o presente trabalho procurou abordar a situação atual dos níveis de fertilidade através da análise de 105.342 amostras de solo provenientes de diferentes regiões do estado do Rio Grande do Sul cedidos pelo CCGL Tecnologia na camada de 0 a 10 cm. Cerca de 42% das amostras apresentaram necessidade de correção da acidez do solo. O fósforo foi o elemento que necessita maior atenção na correção de solo por apresentar 61,8% das amostras em níveis abaixo do teor crítico. O potássio apresentou 72,1% das amostras acima do teor crítico sugerindo baixa resposta a aplicação nos modelos atuais. A correção com enxofre apresenta potencial de resposta a produtividade da cultura da soja. Em um segundo momento, utilizou-se os dados a fim de estudar o equilíbrio dos nutrientes no solo. Foi utilizado a CTCpH7,0 do solo como parâmetro divido em classes, considerando a distribuição normal com um desvio padrão para cada classe, a fim de estudar o comportamento da saturação de bases e do potássio na saturação. Os resultados demonstraram que a saturação por bases, para atingir o pH desejado, variou conforme a CTCpH7,0 do solo. Solos com baixa CTCpH7,0 apresentam tendência de menores percentuais de saturação por bases que um solo com CTCpH7,0 alta. Também se verificou que a CTCpH7,0 do solo influencia a disponibilidade do potássio no equilíbrio de saturação. Solos com CTCpH7,0 acima de 18 cmolc.dm-³ necessitam quantidades de potássio superiores a 240 ppm para atingir o teor crítico de 3% da CTCpH7,0. O próximo passo foi correlacionar os teores dos elementos no solo e sua relação com os teores apresentados pelas análises foliares. Para isso foram realizados amostragens de solo em grid de 2 ha em uma área de produção de soja no município de Cachoeira do Sul, RS. Nesta área foi implantada a cultura da soja e coletadas amostras de folhas e plantas quando estas se encontravam no estádio de florescimento nos mesmos pontos onde foram retirada as amostras de solo. Também realizou-se a determinação com o equipamento Greenseeker a fim de correlacionar os resultados com as amostras de folha e solo. Os resultados das amostras de tecido de plantas inteiras de soja se correlacionam com os teores de potássio no solo e seu percentual na CTCpH7,0. Apesar disso a utilização da análise foliar do 3° trifólio a partir do florescimento como parâmetro para recomendação ainda precisa ser melhor estudado, pois os resultados não deixam claras as relações entre os elementos nas folhas e estes no solo.
26

Paligorsquita como adsorvente para íons de metais de transição: Estudos cinéticos e do equilíbrio / Paligorsquite as adsorbent for transition metallic ion Kinetic and equilibrium study

Oliveira, Andréa Maria Brandão Mendes de 21 December 2011 (has links)
Made available in DSpace on 2015-05-14T13:21:14Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 1123508 bytes, checksum: 0fdb819130cbff24478ae9eb6273c48a (MD5) Previous issue date: 2011-12-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Clay minerals are silicates with importance of environmental, technological and academic view, existing in a large variety as synthetic or natural materials. In this group, the palygorskite is a clay mineral of fibrous habit with 2:1 structure and wide industrial application. This material shows a partial isomorphic substitution of magnesium with aluminum and/or iron and such substitutions result in an excess of negative charges. These charges are associated with specific surfaces resulting in the palygorskite an adsorbent for polar molecules or positive ions. In this work, the palygorskite of Piauí was applied as adsorbent in aqueous solution for removal of copper, cobalt and nickel from simple and binary solutions. The palygorskite was characterized by chemical analysis, XRD, infrared spectroscopy and thermogravimetry. The adsorption experiments for ions in aqueous solution were carried out by batch method in which the effect of reaction time (2-72 h), temperature (303, 313 and 323 K), initial concentration of metal ion (10-3 to 10-2 mol dm-3) at various temperature, pH (2.0, 4.0, 6.0 and 8.0) and ionic strength (solutions of NaNO3 at concentrations of 0.01; 0.005; 0.008 and 0,01 mol dm-3) were systematically varied. The binary mixtures of cations were investigated by varying the reaction time and the initial concentrations of ions in solution. The retention time was 48 h maximum for all cations. The data of time isotherm were fitted to kinetic models of pseudo first order, pseudo second order and intraparticle diffusion, where the data were best described by the second order kinetic model. The isotherms of concentration were fitted to the Langmuir and Freundlich models. The maximum capacities of adsorption for copper (II), nickel (II) and cobalt (II) were 1.28; 1.21 and 1.1 mmol g-1; 1.60; 1.46 and 1,40 mmol g-1 and 0.78; 0,68 and 0,61 mmol g-1 at 303, 313 and 323 K, respectively. The palygorskites saturated with cations were characterized by XRD, infrared spectroscopy and thermogravimetry showing insignificant changes in their structure comparing with the precursor solid. / Os argilominerais são silicatos importantes do ponto de vista ambiental, tecnológico e acadêmico, existindo como materiais sintéticos ou naturais. Neste grupo se destaca a paligorsquita, que é um argilomineral de hábito fibroso de estrutura 2:1 de ampla aplicação industrial. Este mineral pode apresentar substituições isomórficas parciais do magnésio pelo alumínio e/ou ferro e essas substituições resultam num excesso de cargas negativas. Estas cargas associadas a superfícies específicas tornam a paligorsquita um adsorvente para moléculas polares ou íons positivos. Assim neste trabalho, a paligorsquita da região do Piauí foi aplicada como adsorvente em solução aquosa para remoção dos íons cobre, cobalto e níquel individualmente e na forma de soluções binárias. A paligorsquita inicialmente foi caracterizada por análise química, DRX, espectroscopia na região do infravermelho e termogravimetria. Os ensaios de adsorção para a série de íons em solução aquosa foram realizados pelo método em batelada em que os efeitos do tempo de reação (2 a 72 h), temperatura (303, 313 e 323 K), concentração inicial do íon metálico (10-3 a 10-2 mol dm-3) em cada uma das temperaturas, pH (2,0; 4,0; 6,0 e 8,0) e força iônica (soluções de NaNO3 nas concentrações de 0,01; 0,005; 0,008 e 0,01 mol dm-3) foram sistematicamente variados. As misturas binárias dos cátions foram investigadas variando o tempo de reação e as concentrações iniciais dos íons em solução. O tempo de retenção máxima foi de 48 h para todos os cátions. Os dados das isotermas de tempo foram ajustados aos modelos cinéticos de pseudo-primeira ordem, pseudo-segunda ordem e de difusão intrapartícula, sendo melhores descritos pelo modelo de pseudo-segunda ordem. As isotermas de concentração foram testadas frente aos modelos de Langmuir e Freundlich. As capacidades máximas de adsorção para cobre (II), níquel (II) e cobalto (II) foram de 1,28; 1,21 e 1,1 mmol g-1; 1,60; 1,46 e 1,40 mmol g-1 e de 0,78; 0,68 e 0,61 mmol g-1 a 303, 313 e 323 K, respectivamente. As paligorsquitas saturadas com os íons metálicos foram caracterizadas por DRX, espectroscopia na região do infravermelho e termogravimetria mostrando pouca alteração na estrutura comparando com àquela do sólido precursor.
27

Deposição atmosférica de espécies químicas em Ribeirão Preto, uma importante cidade canavieira do estado de São Paulo / Deposição atmosférica de espécies químicas em Ribeirão Preto, uma importante cidade canavieira do estado de São Paulo

Cidelmara Helena Coelho 30 March 2007 (has links)
Amostras de água de chuva foram coletadas no campus da USP Ribeirão Preto (RP) de agosto de 2002 a dezembro de 2005. Cerca de 84% (n=127) das amostras apresentaram excesso de acidez, com pH médio de 5,12. Não se observou sazonalidade no pH de acordo com o período de safra da cana. As concentrações médias ponderadas pelo volume (MPV, em mol L-1): K+ 3,9 (n=175), Na+ 2,1 (n=172), Ca2+ 5,0 (n=175) e Mg2+ 1,8 (n=168), observadas em RP, bem como seus fluxos de deposição por via úmida, foram ligeiramente mais elevadas que aquelas encontradas em chuvas de regiões com características semelhantes. As concentrações destes cátions foram sazonais, com um aumento no período de safra, sendo que a maior diferença foi observada para o íon K+, indicando a sua importante fonte na queima de biomassa. A sazonalidade do íon Ca2+ aponta para a importância das atividades agrícolas, intensificadas no período de safra, na emissão deste cátion para a atmosfera. Observaram-se boas correlações lineares entre as concentrações de Na+ e K+ (0,67626) e de Na+ e Ca2+ (0,77822), indicando a possibilidade de emissões pirogênicas e a ressuspensão do solo serem fontes de emissão de Na+. A MPV de carbono orgânico dissolvido (COD) encontrada em RP foi mais elevada que na Amazônia, onde também há intensa queima de biomassa, porém seus fluxos por via úmida em ambas as regiões foram similares (0,42 molCm-2ano-1). As concentrações de COD em RP apresentaram correlações lineares significativas com K+ (0,70341) e com Ca2+ (0,61638), apontando para a queima de biomassa e ressuspensão do solo como fontes importantes de emissão de carbono orgânico para a atmosfera. As concentrações de COD nas chuvas de Araraquara foram ainda maiores que em RP, indicando pronunciadas fontes locais naquela cidade. As MPV (nmol L-1) de Cd 0,54 (n=56), Pb 3,02 (n=94) e Cu, 19,9 (n=98), encontradas nas chuvas de RP foram semelhantes a regiões urbanas e industriais do hemisfério norte, enquanto a concentração de Al (448 nmol L-1, n=126) foi menor, e a de Zn (405 nmol L-1, n=120) apresentou-se dentro das faixas de concentrações relatadas nestes locais. Com exceção de Cd, os demais metais analisados (Pb, Cu, Zn e Al) também apresentaram concentrações significativamente maiores (P=0,05) nas chuvas durante o período de safra, indicando que a queima de biomassa e as atividades agrícolas podem aumentar a emissão destes metais para a atmosfera de RP. A correlação linear significativa entre Pb e Ca2+ (0,53845), indica a participação da ressuspensão do solo no aporte atmosférico de Pb em RP, enquanto a ausência de correlação linear entre Zn e K+ (0,20182) parece indicar a presença de outras fontes significativas de Zn para a atmosfera de RP, além da queima de biomassa. O cálculo do fator de enriquecimento demonstra que Cd, Zn, Pb e Cu estão enriquecidos com relação ao solo na chuva de RP, sugerindo que estes podem ter fontes antrópicas locais e / ou distantes. A análise preliminar de componentes principais não esclareceu o peso das diferentes fontes de emissão atribuídas neste trabalho. / Rain water samples were collected based on events at the University of São Paulo - campus Ribeirão Preto - from August 2002 to December 2005. About 84% (n=127) of the samples had excess of acidity, with an average pH of 5.12. There was no correlation between the pH values and the sugar cane harvest period. The Volume Weighed Means (VWM, in mol L-1) for K+ 3.9 (n=175), Na+ 2.1 (n=172), Ca2+ 5.0 (n=175) and Mg2+ 1.8 (n=168), and their wet fluxes in RP were slightly higher than those reported to regions with similar characteristics. The concentrations for these cations were seasonal, with higher values during the harvest period. The largest difference was observed for K+, indicating its important source in the biomass burning activity. The seasonality showed for Ca2+ is probably related to the higher soil resuspension during the more intense agricultural activities. A good linear correlation observed between Na+ and K+ (0.67626) and between Na+ and Ca2+ (0.77822), suggest that Na+ may have important pirogenic as well as soil dust sources. The VWM for Dissolved Organic Carbon (DOC) in RP was higher than that reported for rainwater in the Amazon region (where the biomass burning is also intense); however, the wet fluxes from both sites were very similar (0.42 mol C m-2 ano-1). DOC concentrations were well correlated with K+ (0.70341) and Ca2+ (0.61638), suggesting that the biomass burning as well as soil dust can be important sources of organic carbon to the atmosphere. DOC concentrations in rainwater from Araraquara were even higher than those for RP, showing a high local source of organic carbon. The VWM (nmol L-1) for Cd 0.54 (n=56), Pb 3.02 (n=94) and Cu 19.9 (n=98) found in the rainwater from RP were similar to urban and industrialized regions of the Northern Hemisphere, while for Al (448 nmol L-1, n=126) it was lower, and for Zn (405 nmol L-1, n=120) the VWM was within the range reported for such areas. Except for Cd, all the other metals measured (Pb, Cu, Zn and Al) also showed higher concentrations (P=0.05) in rainwater samples during the harvest period, suggesting that biomass burning and intensive agricultural activities can increase these species concentrations in the atmosphere. The significant linear correlation between Pb and Ca2+ (0.53845) indicates that soil inputs can be of relevance for Pb atmospheric inputs in RP. On the other hand, the absence of linear correlation between Zn and K+ (0.20182) seems to indicate the presence of other important sources for Zn to the atmosphere besides biomass burning. The calculated Enrichment Factor showed that Cd, Zn, Pb and Cu are anomalously enriched in RP rainwater in relation to soil, suggesting these metals may have antroprogenic local sources as well as distant ones. The preliminary statistical analysis of principal components did not clarify the weight of the different sources of emission attributed in this work.
28

Desenvolvimento de um fotômetro portátil e de procedimentos analíticos automáticos para determinação de ânions e cátions em fontes de captação de águas para uso doméstico e industrial / Development of portable photometer and automatic analytical procedures for anions and cations determination in sources of water captation for domestic and industrial uses

Feres Junior, Mario Almir 18 December 2006 (has links)
Neste trabalho, foi desenvolvido equipamento portátil e procedimentos analíticos automáticos para determinação de cátions e anions em águas usadas para consumo humano e suprimento. Os procedimentos foram baseados no processo de multicomutação em fluxo e detecção fotométrica empregando fotômetro feito no laboratório. Os sistemas de fluxo foram construídos empregando válvulas solenóide, com interface independente de comutação acionadas por computador usando apenas um canal de bombeamento. O sistema proposto foi controlado por um computador rodando um software escrito em QuickBasic 4.5. Os dói fotômetros baseados em LED foram desenvolvidos usando como detectores de radiação foto-transistores e foto-diodos. Nos dois casos a fonte de radiação (LED) e o foto-detector foram acoplados a cela de fluxo obtendo assim, uma unidade compacta. O fotômetro foi projetado para usar um foto-transistor para determinações seqüenciais de nitrato, nitrito, ferro(II), ferro(III) em águas de rios.O fotômetro proposto usa um foto-diodo para determinação de cloreto por turbidimetria, fosfato e amonium por fotometria. A sistema de fluxo foi desenhado associando-se os processos de multicomutação e multisite garantindo redução de reagente e de efluente. O sistema sistema foi empregado para determinação de cloreto, fosfato e amônio em águas de rios. Os dois sistemas propostos apresentaram excelente performance incluindo boa precisão, freqüência analítica e baixo consumo de reagente. Além disso, o sistema baseado em multisite apresentou baixo volume de efluente gerado. As dimensões reduzidas de ambos os fotômetros e do modulo de analise em fluxo, permitiram a portabilidade, o que possibilita sua aplicação em condições de campo. / In this work it was developed a portable apparatus and automatic analytical procedures for the determination of cations and anions in waters used for human consumption and industrial provisioning. The procedures were based on the multicommutation process in flow analysis and detection was performed using a homemade photometer. The flow systems were designed employing a set of solenoid valves, which were assembled to work as independent commutation units, thus under computer control several solutions were handled using a single pumping channel. The proposed system was controlled by computer running a software wrote in QuickBasic 4.5. The two LED based photometers were developed using as light detection a phototransistor and a photodiode. In both cases, the radiation source (LED) and the photodector were coupled to the flow cell in order to obtain compact unit. The photometer designed using a phototransistor was employed for the sequential determination of nitrate, nitrite, iron(II) and iron(III) in river water. The photometer designed using a photodiode was employed in the system used for the determination of chloride by turbidimetry, phosphate and ammonium by photometry. The flow system was designed associating the multisite and multicommutation process intending reduction of the reagent consumption and waste generation. The useful of the system was proved performing the determination of chloride, ammonium and phosphate in river water. The two proposed systems presented very overall performance including precision and accuracy, analytical frequency and low reagent consumption. Furthermore, the system based on multisite approach presented a very low volume of waster generation. The reduced dimensions of both photometer and flow system module allow their portability, thus we can suggest that the proposed systems are reliable for work in field condition.
29

Desenvolvimento de equipamento de eletroforese capilar com detecção por condutividade sem contato para a separação de íons inorgânicos / Development of a capillary electrophoresis system with contactless conductivity detection (c4d) for the separation of inorganic ions

Spengler, Cristiane 16 March 2009 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / This work describes the development and evaluation of a home-made capillary electrophoresis (CE) system based on the capacitively coupled contactless conductivity detection (C4D) for the application in capillary zone electrophoresis (CZE). The C4D detection is based on prototypes previously described in the literature. The equipment constructed has a hydrodynamic injection system (gravity), a temperature control system based on the heating of the system and it is equipped with two carousels for the sample changing. The electrophoretic system developed in this work has a high automation degree in relation to other existing CE systems. All the components of the CE system are operated by a computer interface, including the sample changers that allow the manipulation of solutions in a fully automated way. The control of the components of the CE system and the data acquisition were made by using a software, which was developed in a Delphi 7.0 language. After the construction and configuration of the CE system, the performance was initially evaluated by applying some methods previously described in the literature for the separation of Na(I), K(I), Ca(II) and Mg(II). The results are in agreement with the literature and show the proper performance of the home-made CE C4D system. The developed system was used for the simultaneous determination of the metallic species Zn(II), Cr(III), Pb(II), Cd(II), Co(II), Cu(II), Ni(II) and Tl(I) in different samples. The separation of 8 cations was investigated by using working electrolytes containing 2-[N-morpholino]ethanesulfonic acid (MES) and histidine (His) at different compositions. The use of complexing agents and an organic solvents as additives was also evaluated. The optimized conditions enabled the determination of 8 cations in a single run after 15 minutes using a solution containing 20 mmol L−1 MES/His (pH 5.0) and 5% MeOH (v/v) as working electrolyte, 10 kV as separation potential and the C4D detector operating at 600 kHz and 2 Vpp. The constructed CE-C4D system was shown to be very reproducible for electrophoretic analysis of metallic cations, with relative standard deviations (RSD) for the migration times of all the studied cations ranging from 2.6 to 9.2%. The detection limits calculated for the 8 cations ranged from 1.69 to 22.17 μmol L−1, which allows the application of the methodology for determinations in real samples using the developed electrophoretic system. / Este trabalho descreve a construção e avaliação de um sistema de eletroforese capilar com detecção condutométrica sem contato acoplada capacitivamente (CE−C4D) para sua aplicação em eletroforese capilar de zona (CZE). A detecção por C4D é baseada em protótipos previamente descritos na literatura. Para o equipamento construído foram desenvolvidos um sistema de injeção de amostra por gravidade e um sistema de controle de temperatura por aquecimento, além de estar equipado com 2 amostradores acoplados ao sistema eletroforético, possuindo assim um grau de automação maior em relação aos outros sistemas já existentes. Todos os componentes do sistema são operados através de uma interface via computador, incluindo os amostradores que permitem a manipulação de soluções de forma completamente automatizada. O controle dos componentes do sistema eletroforético e a aquisição de dados foram feitos mediante um software escrito em linguagem Delphi 7.0. Após a sua montagem e configuração, o desempenho do sistema eletroforético foi inicialmente testado de acordo com metodologias previamente descritas na literatura para a separação de Na(I), K(I), Ca(II) e Mg(II). Os resultados obtidos estão de acordo com os encontrados na literatura e indicam o desempenho adequado do sistema CE C4D construído em laboratório. O sistema desenvolvido foi empregado no desenvolvimento de um método eletroforético para a determinação simultânea dos cátions metálicos Zn(II), Cr(III), Pb(II), Cd(II), Co(II), Cu(II), Ni(II) e Tl(I) em amostras de água. A separação dos 8 cátions foi investigada em eletrólitos de trabalho contendo ácido 2-N-morfolinoetanossulfônico (MES) e histidina (His) com diferentes composições. O uso de agentes complexantes e de solventes orgânicos como aditivos também foi avaliado. A melhor condição possibilitou a determinação dos 8 cátions em uma única corrida após 15 minutos utilizando a solução de MES/His 20 mmol L−1 (pH 5,0) e MeOH 5% (v/v) como eletrólito de trabalho, 10 kV como potencial de separação, com o detector C4D operando em 600 kHz e 2 Vpp. O sistema CE C4D construído demonstrou ser altamente reprodutível para análises eletroforéticas de cátions metálicos, o qual forneceu valores de desvio padrão relativo entre 2,6 e 9,2% para os tempos de migração de todos os cátions estudados. Limites de detecção calculados para os 8 cátions entre 1,69 e 22,17 μmol L−1 permitem a aplicação da metodologia para determinações em amostras reais empregando o sistema eletroforético desenvolvido.
30

Desenvolvimento de um fotômetro portátil e de procedimentos analíticos automáticos para determinação de ânions e cátions em fontes de captação de águas para uso doméstico e industrial / Development of portable photometer and automatic analytical procedures for anions and cations determination in sources of water captation for domestic and industrial uses

Mario Almir Feres Junior 18 December 2006 (has links)
Neste trabalho, foi desenvolvido equipamento portátil e procedimentos analíticos automáticos para determinação de cátions e anions em águas usadas para consumo humano e suprimento. Os procedimentos foram baseados no processo de multicomutação em fluxo e detecção fotométrica empregando fotômetro feito no laboratório. Os sistemas de fluxo foram construídos empregando válvulas solenóide, com interface independente de comutação acionadas por computador usando apenas um canal de bombeamento. O sistema proposto foi controlado por um computador rodando um software escrito em QuickBasic 4.5. Os dói fotômetros baseados em LED foram desenvolvidos usando como detectores de radiação foto-transistores e foto-diodos. Nos dois casos a fonte de radiação (LED) e o foto-detector foram acoplados a cela de fluxo obtendo assim, uma unidade compacta. O fotômetro foi projetado para usar um foto-transistor para determinações seqüenciais de nitrato, nitrito, ferro(II), ferro(III) em águas de rios.O fotômetro proposto usa um foto-diodo para determinação de cloreto por turbidimetria, fosfato e amonium por fotometria. A sistema de fluxo foi desenhado associando-se os processos de multicomutação e multisite garantindo redução de reagente e de efluente. O sistema sistema foi empregado para determinação de cloreto, fosfato e amônio em águas de rios. Os dois sistemas propostos apresentaram excelente performance incluindo boa precisão, freqüência analítica e baixo consumo de reagente. Além disso, o sistema baseado em multisite apresentou baixo volume de efluente gerado. As dimensões reduzidas de ambos os fotômetros e do modulo de analise em fluxo, permitiram a portabilidade, o que possibilita sua aplicação em condições de campo. / In this work it was developed a portable apparatus and automatic analytical procedures for the determination of cations and anions in waters used for human consumption and industrial provisioning. The procedures were based on the multicommutation process in flow analysis and detection was performed using a homemade photometer. The flow systems were designed employing a set of solenoid valves, which were assembled to work as independent commutation units, thus under computer control several solutions were handled using a single pumping channel. The proposed system was controlled by computer running a software wrote in QuickBasic 4.5. The two LED based photometers were developed using as light detection a phototransistor and a photodiode. In both cases, the radiation source (LED) and the photodector were coupled to the flow cell in order to obtain compact unit. The photometer designed using a phototransistor was employed for the sequential determination of nitrate, nitrite, iron(II) and iron(III) in river water. The photometer designed using a photodiode was employed in the system used for the determination of chloride by turbidimetry, phosphate and ammonium by photometry. The flow system was designed associating the multisite and multicommutation process intending reduction of the reagent consumption and waste generation. The useful of the system was proved performing the determination of chloride, ammonium and phosphate in river water. The two proposed systems presented very overall performance including precision and accuracy, analytical frequency and low reagent consumption. Furthermore, the system based on multisite approach presented a very low volume of waster generation. The reduced dimensions of both photometer and flow system module allow their portability, thus we can suggest that the proposed systems are reliable for work in field condition.

Page generated in 0.5012 seconds