• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 347
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 365
  • 357
  • 351
  • 342
  • 292
  • 286
  • 280
  • 272
  • 71
  • 58
  • 53
  • 47
  • 45
  • 45
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Avaliação de medidas lineares para osteotomia tipo Le Fort I por meio de diferentes programas de imagem utilizando a tomografia computadorizada / Assessment of linear measurements for Le Fort I osteotomy with different imaging software using computed tomography

Santos, Bruno Felipe Gaia dos 11 September 2013 (has links)
O sucesso da cirurgia ortognática está relacionado com diversos fatores como análise facial precisa e acurada, e exames de imagem com alta qualidade. Atualmente, diversos programas de imagens tridimensionais, comerciais e abertos, estão disponíveis no auxílio diagnóstico, elaboração do plano de tratamento e simulação do procedimento cirúrgico para correção das deformidades dentofaciais. Entretanto, estudos avaliando os diferentes métodos de mensuração linear empregados pelos programas de imagem por meio da reconstrução 3D no planejamento da osteotomia tipo Le Fort I são escassos e, maiores esclarecimentos sobre sua precisão e a acurácia são necessários. O objetivo deste estudo foi estabelecer: a) precisão e acurácia de medidas lineares tridimensionais para osteotomia tipo Le Fort I obtidas por meio da tomografia computadorizada multislice (TCMS) e feixe cônico (TCFC) e b) comparar a precisão e acurácia de medidas lineares para osteotomia tipo Le Fort I realizadas por meio de três programas de imagem utilizando a 3D-TCFC. A amostra foi constituída por onze crânios secos submetidos à TCMS 64 canais e TCFC. As reconstruções tridimensionais (3D-TC) foram geradas, e medidas lineares (n=11) baseadas em estruturas e pontos anatômicos de interesse à osteotomia tipo Le Fort I foram realizados independentemente, por dois radiologistas experientes, duas vezes cada, utilizando programa Vítrea 3.8.1 em reconstruções 3D-TCMS e 3D-TCFC e os programas OsiriX 1.2 64-bit e Dolphin Imaging versão 11.5.04.35 por meio da 3D-TCFC. Sequencialmente, um terceiro observador experiente e calibrado, que não participou da análise das imagens, realizou as medidas sobre os crânios secos utilizando paquímetro digital (padrão ouro) com quais as medidas foram comparadas. A análise intra e inter-observadores assim como as correlações individuais de cada medida foram realizadas utilizando o coeficiente de correlação intra-classe (CCI), sendo o intervalo de confiança adotado de 95%. Os resultados demonstraram na análise intra-observador, utilizando o programa Vítrea, correlação excelente para todas as medidas variando de 0,87 a 0,96 e 0,82 a 0,98 para os observadores 1 e 2 respectivamente utilizando a TCMS e de 0,84 a 0,98 e 0,80 a 0,98 utilizando a TCFC. A análise inter-observadores variou de 0,85 a 0,98 para a TCMS e de 0,80 a 0,99 para a TCFC. A análise intra-observador utilizando os diferentes programas de imagem na TCFC apresentou variações de 0,90 a 0,97 (Vítrea), 0,65 a 0,97 (OsiriX) e 0,51 a 0,94 (Dolphin). Na análise inter-obsevador obtivemos valores de 0,92 a 0,99 e 0,88 a 0,98 para os observadores 1 e 2 respectivamente utilizando o Vítrea, 0,58 a 0,90 e 0,48 a 0,85 para o programa OsiriX e de 0,80 a 0,96 e 0,57 a 0,92 com o programa Dolphin. O programa Vítrea não apresentou diferenças estatisticamente significante nas análises intra e inter-observador e medidas físicas utilizando a TCMS e TCFC. Em relação à análise dos programas, diferenças estatisticamente foram constatadas com o programa OsiriX e Dolphin em relação ao padrão ouro. / The success of orthognathic surgery depends on many factors as precise and accurate facial analysis and high quality imaging exams. Nowadays a lot of commercial and open-source three-dimensional software programs currently available to assist diagnosis, elaboration of treatment planning, and to predict outcomes related to orthognathic surgery. The aim of this study was to establish: a) the precision and accuracy of three-dimensional linear measurements for Le Fort I osteotomy, obtained from multislice computed tomography (MSCT) and cone-beam computed tomography (CBCT) scans and b) compare the precision and accuracy of linear measurements for Le Fort I osteotomy performed by three different imaging software programs and obtained from 3D-CBCT images. The study population consisted of 11 dried skulls submitted to 64-row MSCT and CBCT scans. Three-dimensional reconstructed images (3D-CT) were generated, and linear measurements (n = 11) based on anatomical structures and landmarks of interest for Le Fort I osteotomy were performed independently by 2 oral and maxillofacial radiologists, twice each, using Vítrea 3.8.1 software for 3D-MSCT and 3D-CBCT and OsiriX 1.2 64-bit and Dolphin Imaging version 11.5.04.35 from 3D-CBCT. Subsequently, a third examiner expert in anatomical analysis and calibrated, who did not evaluate the images, performed measurements on dry skulls using a digital caliper (gold standard) with which the measurements were compared. The analyses of intra- and inter-observer as well as the individual correlations of each measurement were performed using the coefficient of intra-class correlation (ICC), with a confidence interval of 95 %. The intra-observer results showed that using the Vitrea program, excellent correlation for all measurements were reached with ICC values ranging from 0.87 to 0.96 and 0.82 0.98 for observers 1 and 2 respectively using the MSCT and 0.84 to 0.98 and 0.80 to 0.98 using CBCT. Inter-observer analysis ranged from 0.85 to 0.98 for MSCT and 0.80 to 0.99 for CBCT. The intra-observer analysis using the different programs using CBCT images varied from 0.90 to 0.97 for Vitrea, 0.65 to 0.97 for OsiriX and 0.51 to 0.94 using Dolphin. Inter-observer analysis demonstrated values ranging from 0.92 to 0.99 and 0.88 0.98 for observers 1 and 2 respectively using the Vitrea; 0.58 to 0.90 and 0.48 to 0.85 for OsiriX, and 0.80 to 0.96 and 0.57 to 0.92 using Dolphin. Vítrea software showed no statistically significant differences for intra-and inter-observer analysis and physical measurements using MSCT and CBCT. Regarding the analysis of softwares, statistical differences were found with the program OsiriX and Dolphin in comparison to gold standard.
232

Morfologia labial de interesse para reconstrução facial forense / Morphology lip of interest for forensic facial reconstruction

Dias, Paulo Eduardo Miamoto 01 November 2013 (has links)
A Reconstrução Facial Forense (RFF) é uma área da Antropologia Forense que busca aproximar a aparência de um indivíduo desconhecido por meio de reconstrução dos tecidos moles sobre seu crânio, após seu estudo antropológico. A RFF divulgada nos meios de comunicação visa a um reconhecimento, que pode desencadear um processo de identificação humana. Conhecer as relações entre tecidos duros e moles é essencial para se aumentar a precisão das RFFs. Neste estudo, buscou-se reunir informações antropométricas sobre a boca e suas proporções. Foram constituídas duas amostras a partir de um acervo de tomografias computadorizadas. A amostra 1 (n=327) consistiu em homens (n=127) e mulheres (n=185) entre 11 e 81 anos, divididos em seis faixas etárias e buscou verificar as distâncias lineares delimitadas por pontos anatômicos em tecido mole: altura da zona vermelha da boca, largura da boca, proporção entre os mesmos e possibilidade de se estimar a largura da boca a partir da distância intercanina. A amostra 2 (n=108) consistiu em homens (n=40) e mulheres (n=68) entre 20 e 81 anos, divididos em três faixas etárias e buscou verificar as proporções entre altura da zonas vermelha da boca, largura da boca e distâncias lineares entre pontos craniométricos em tecidos duros. As medições foram feitas com o programa OsiriX e os resultados foram analisados através de através de estatística descritiva para todas as variáveis estudadas, por meio da comparação entre as médias, os desvios padrão e as diferenças entre as médias, com intervalo de confiança de 95% (IC95%) e aceitando nível de significância de 5% (p<0,05). Para a amostra 1, a altura da zona vermelha correspondeu a aproximadamente 26% da largura da boca, em ambos os sexos, com tendência a diminuir ao longo do tempo. A largura da boca aumentou ao longo do tempo em homens e manteve-se estável em mulheres. À distância intercanina se atribuiu o valor médio de 75% da largura da boca, em homens, e 80% da largura da boca em mulheres. Para a amostra 2, à distância entre os pontos infradentale e supramentale se atribuiu em média 55% da altura da zona vermelha para ambos os sexos, e entre os pontos philtrum medium e supradentale, em média 85% da altura da zona vermelha em homens, e 88% da mesma medida em mulheres. À distância entre os forames mentuais, se atribuiu em média 97% da largura da boca em mulheres, e em homens 93% deste valor. A reunião de dados antropométricos da boca para a população brasileira pode contribuir para aumentar a precisão das RFFs e auxiliar a identificação humana. / Forensic Facial Reconstruction (FFR) is an area of Forensic Anthropology that seeks to approximate the appearance of an unknown individual by reconstructing soft tissues over ones skull after an anthropological analysis. The FFR published in the media aims at a recognition, which can trigger a process of human identification. Knowing the relationship between hard and soft tissues is crucial to increase the accuracy of FFRs. In this study, we sought to gather anthropometric information on the mouth and its proportions. Two samples were taken from a collection of CBCT scans. Sample 1 (n=327) consisted of men (n=127) and women (n=185) aged between 11 and 81 years old, divided into six age groups and verified the linear distances defined by anatomical landmarks in soft tissue: vermillion height, mouth width, the proportion between these and the possibility of estimating mouth width from the intercanine distance. Sample 2 (n=108) consisted of men (n=40) and women (n=68) aged between 20 and 81 years old, divided into three age groups, and verified the proportions between the vermilllions of the mouth, mouth width and linear distances marked in bony craniometrical landmarks. The measurements were made in OsiriX software and the results were analyzed by averages, standard deviations and differences between the averages. For sample 1, vermillion height corresponded to approximately 26% of mouth width, in both genders, with a tendency to decrease over time. Mouth width increased over time in men, and kept stable values in women. The intercanine distance corresponded to about 75% of mouth width in men, and 80% of the mouth width in women. For sample 2, the distance between the landmarks infradentale and supramentale and was on average 55% of the vermillion height in both genders, and the distance between the landmarks philtrum medium and supradentale was about 85% of the vermillion height in men and about 88% of the same measure, in women. The distance between the mental foramina was on average 97% of the mouth width in women, and 93% of this distance in men. Gathering anthropometric information on the mouth for the Brazilian population can contribute to increase the accuracy of FFRs and assist human identification.
233

Avaliação por meio da tomografia computadorizada por feixe cônico de vias aéreas superiores de pacientes com atresia de palato, que possuem mordida cruzada posterior / Evaluation by means of cone beam computed tomography of the upper airways of patients with atresia of the palate, which have posterior crossbite

Hernandez-Zanet, Angelica Maria 24 July 2012 (has links)
A atresia do palato ou deficiência maxilar transversa tem comprovado a sua influência na relação craniofacial e respiratória, por isso, diversos métodos de expansão palatina têm sido estudados para que haja uma melhora significativa, principalmente dos fatores respiratórios destes pacientes. O uso da tomografia por feixe cônico iniciou um novo conceito de estudo cefalométrico em terceira dimensão, no qual se consegue avaliar o paciente em todos os planos, sem que haja sobreposições de estruturas, podendo avaliar com precisão as relações craniofaciais, as vias aéreas e a relação destas estruturas. Portanto, o uso da tomografia computadorizada com ênfase na área ortodôntica, nos permite realizar um diagnóstico completo pré-tratamento ortodôntico, no qual objetivamos avaliar a correlação entre mordida cruzada posterior e a obstrução das vias aéreas superiores por meio de tomografia computadorizada por feixe cônico (TCFC). Foram utilizadas TCFC de arquivo de 32 pacientes com idade entre 6 e 14 anos, divididos em dois grupos: um grupo de 16 crianças com mordida cruzada posterior e o grupo controle . O critério de exclusão da amostra foi a realização de tratamento ortodôntico prévio, ter realizado cirurgia no complexo maxilo mandibular ou ser portador de alterações patológicas na região. Foi realizada a comparação das medidas da largura e da altura do palato em relação às medidas lineares e ao volume segmentado e total das vias aéreas superiores dos pacientes com e sem mordida cruzada posterior. No grupo com mordida cruzada, para a correlação das medidas ENP-AD2, ENP-AD1 com o volume da Baixa Naso Faringe (BNF), teve correlação moderada com a largura do palato (0,05 < p=0,089 < 0,10). Entretanto, no grupo de mordida cruzada, foi observada correlação significante entre a largura do palato e o volume total (VT). Em ambos os casos, a correlação foi positiva (r=0,786 para largura do palato com o Volume da Alta Velo Faringe (AVF) e r=0,662 para largura do palato com o VT), isto é, quanto maior a largura do palato, maior o Volume AVF e maior o VT. Estes resultados demonstram a importância do uso da TCFC, pois não foram encontradas diferenças significativas nas medidas lineares do grupo com mordida cruzada posterior e o grupo controle. Concluiu-se neste trabalho que apenas as medidas lineares não fornecem informações suficientes para a avaliação das vias aeras superiores; a profundidade do palato não possui correlação com as alterações das vias aéreas em pacientes com atresia maxilar; o grupo com mordida cruzada posterior apresentou moderada correlação da largura do palato com as medidas ENP-AD2, ENP-AD1 e o Volume da Baixa Naso Faringe; o grupo com mordida cruzada posterior apresentou correlação positiva da largura do palato com o volume da Alta Velo Faringe e com o Volume Total. / The palate atresia or transverse maxillary deficiency has proven its influence in relation craniofacial and respiratory therefore various methods of palatal expansion have been studied so there is a significant improvement, especially respiratory factors of these patients. The use of cone beam computed tomography initiated a new concept of three-dimensional cephalometric study, in which we can assess the patient at all levels, without overlapping structures, and can accurately assess the relations craniofacial, the airways and the relationship these structures. Therefore, the use of computed tomography with emphasis on orthodontic allows us to carry out a full pre-orthodontic treatment, in which we aimed to evaluate the correlation between posterior crossbite and obstruction of the upper airways by cone beam computed tomography (CBCT). We used CBCT file of 32 patients aged 6 to 14 years, divided into two groups: a group of 16 children with posterior cross bite and control groups. The exclusion criteria of the sample was the realization of previous orthodontic treatment, having undergone surgery on mandibular complex maxillo or be in possession of pathological changes in the region. Was performed comparing measurements of the width and height of the palate in relation to linear measurements and volume segmented and total upper airway of patients with and without posterior cross bite. In the group with crossbite, for correlating the ENP-AD2, ENP-AD1 with the volume of Lower Pharynx Naso (BNF), had a moderate correlation with the width of the palate (0.05 <p = 0.089 <0.10). However, in the group of crossbite was no significant correlation between the width of the palate and the total volume (VT). In both cases, positive correlation was found (r = 0.786 for the width of the palate with the volume of the high speed Pharynx (AVF) and r = 0.662 for the width of the palate with VT), i.e., the larger the width of the palate, more Volume AVF and the higher the VT. These results demonstrate the importance of using CBCT, since there were no significant differences in linear measurements of posterior crossbite group and the control group. It was concluded in this study that only the linear measurements do not provide sufficient information to evaluate upper airway Aeras, the depth of the palate has no correlation with changes in the airways of patients with maxillary atresia, the group with posterior crossbite showed moderate correlation the width of the palate with measures ENP-AD2, AD1 and ENP-Low Volume Pharynx Naso, the group with posterior cross bite was positively correlated with the width of the palate volume of Alta Velo Pharynx and the Total Volume.
234

Estudo comparativo dimensional tomográfico do côndilo mandibular de indivíduos com deficiência transversal de maxila / Comparative dimensional tomographic study of the mandibular condyle of individuals with transversal maxillary deficiency

Gonçales, Andrea Guedes Barreto 06 March 2015 (has links)
A deficiência transversal de maxila, caracteriza-se por mordida cruzada posterior uni ou bilateral, dentes apinhados e ou rotacionados, e pelo formato ogival do palato. O tratamento em indivíduos adultos tem sido realizado a partir da expansão de maxila cirurgicamente assistida (EMCA), que resulta em efeitos esqueléticos e dentários no arco superior, com expectativa de efeitos no arco inferior. Neste estudo nos propusemos avaliar a ocorrência de alterações dimensionais nos côndilos mandibulares, de pacientes com deficiência transversal de maxila, e submetidos a expansão cirurgicamente assistida em imagens obtidas por tomografias computadorizadas de feixe cônico (TCFC) de catorze indivíduos com deficiência transversal de maxila, sendo cinco homens e nove mulheres, com idades entre 24 e 28 anos. Na reformatação axial as medidas foram obtidas no sentido, látero-medial, póstero-anterior lateral, póstero-anterior central e pósteroanterior medial da superfície articular. Nas reformatações coronais, mensurou-se os sentidos látero-medial superior, látero-medial inferior, látero-medial médio e súperoinferior. Dentre as medidas obtidas e submetidas à análise estatística pelo teste t pareado, somente as medidas axial póstero-anterior lateral esquerda (-0,90mm), coronal médio direita (-1,24mm), coronal inferior esquerda (1,78mm), coronal súpero-inferior direita (0,76mm), axial póstero-anterior lateral (-0,74mm) e coronal inferior (-1,13mm) foram estatisticamente significativas. Os resultados obtidos na amostra estudada nos permitiram concluir que: em indivíduos com deficiência transversal de maxila e submetidos a EMCA, ocorreram alterações dimensionais nos côndilos mandibulares, que puderam ser entendidas por remodelação, uma vez que caracterizaram-se por aumento e redução, dependendo da localização da medida realizada. / Transverse maxillary deficiency is characterized by posterior uni or bilateral crossbite, crowded and rotated teeth, as well as high palate. Its treatment in adult individuals is surgically assisted rapid palatal expansion (SARPE). This procedure not only has skeletal and dental effects in the upper arch, but also expresses effects in the lower arch. The objective of this study was to verify the occurrence of dimensional alterations in the mandibular condyles of patients with transversal maxillary deficiency submitted to surgically assisted maxillary expansion. Measurements by cone beam computed tomography (CBCT) of the mandibular condyles, axial plains, lateromedial sizes, posterior-anterior lateral, posterior anterior central, and posterior-anterior medial of the articular surface were performed. In the coronal reformats, the superior lateral medial, inferior lateral medial, medium lateral medial, and superior inferior sizes were measured. CBCT images of fourteen individuals with transversal maxillary deficiency were used, five male and nine female with an average age of 24.28 years. Among the values obtained and submitted to statistical analysis by the paired t-test, only the left posterior-lateral anterior axial measurements (-0.90mm), right middle coronal (-1.24mm), left inferior coronal (1.78mm), right superior-inferior coronal (0.76mm), axial anterior-posterior lateral (-0.74mm) and inferior coronal (-1.13mm) were statistically significant. It was concluded that in individuals with maxillary transversal deficiency that underwent surgically assisted rapid palatal expansion (SARPE), dimensional alterations occurred in the mandibular condyles, which can be understood by remodeling, once they are characterized by an increase and reduction, depending on the location where the measurement was performed.
235

Periodontite apical induzida em cães: efeito do tratamento endodôntico. Estudo microbiológico, tomográfico e de microscopia confocal

Zapata, Ronald Ordinola 05 November 2009 (has links)
Este trabalho teve o objetivo de avaliar a capacidade da bactéria Enterococcus faecalis em induzir periodontite apical no modelo experimental canino; verificar se o preparo químico-mecânico afeta a sobrevivência dessa bactéria no sistema de canais radiculares e avaliar o reparo desses dentes por meio de radiografia periapical e tomografia computadorizada cone beam. Dentes com e sem tratamento endodôntico foram avaliados por meio de microscopia confocal de varredura a laser. Para tal, foram utilizados 2 cães. A bactéria Enterococcus faecalis foi inoculada nos canais de 4 pré-molares superiores, 11 prémolares inferiores e 9 incisivos superiores. As câmaras pulpares foram seladas e, após 60 dias, os canais das raízes distais dos pré-molares e de 7 incisivos superiores foram submetidos a tratamento endodôntico em sessão única e os canais das raízes mesiais dos pré-molares e 2 incisivos superiores foram deixados sem tratamento (controle). Amostras microbiológicas foram feitas antes e após o preparo químico-mecânico. O reparo foi avaliado após 6 meses do tratamento mediante radiografias periapicais e por tomografia computadorizada cone beam. A comparação entre as imagens obtidas após o período experimental pelos 2 métodos foi feita por medições da área em mm2 de cada lesão encontrada, utilizando o software ImageTool Os resultados mostraram que a presença de periodontite apical crônica foi verificada em todos os dentes inoculados, independentemente da colonização pela bactéria Enterococcus faecalis ou pela flora mista. O preparo químico-mecânico reduziu significativamente o número de bactérias no interior dos canais radiculares (p<0.05). Os resultados radiográficos e tomográficos demonstraram lesões de menor diâmetro nos dentes tratados endodonticamente em comparação ao grupo controle (p<0.05). A comparação entre os métodos demonstrou diferença estatística entre eles sendo evidenciada áreas radiolúcidas maiores utilizando a tomografia cone beam em comparação com a radiografia periapical (p<0.05). Concluiu-se que a bactéria Enterococcus faecalis induziu periodontite apical crônica similarmente à flora mista; o tratamento endodôntico reduziu o número de bactérias cultiváveis significativamente embora sem relação com o reparo radiográfico. Os dentes tratados em sessão única apresentavam lesões menores em comparação aos não-tratados e as áreas das lesões observadas na TC cone beam foram maiores do que as áreas encontradas nas radiografias periapicais. A microscopia confocal e o método proposto neste estudo se mostraram eficazes para determinar, qualitativamente, a viabilidade bacteriana e a distribuição de ácidos nucléicos bacterianos dentro dos túbulos dentinários. Houve diferença entre a dentina infectada in vitro com o padrão de infecção in vivo, caracterizada pela presença de biofilmes aderidos à parede do canal radicular. / The aims of this study were to evaluate the Enterococcus faecalis ability to induce apical periodontitis in dogs root canals, to verify the bacterias ability to survive to the cleaning and shaping procedures and to assess the healing of the induced apical periodontitis by periapical radiograph and cone beam computed tomography. Also, endodontically treated and non-treated teeth were evaluated by confocal laser scanning microscope. Two mongrel dogs were used in the experiment. Enterococcus faecalis strain was inoculated into the root canals of 4 maxillary premolars, 11 mandibular premolars and 9 maxillary incisors. After 60 days the root canals of the distal roots of the mandibular and maxillary pre-molars and 7 maxillary incisors were endodontically treated. The premolars mesial root canal and 2 maxillary incisors were used as control (no treatment). Microbiologic samples were done after and before the cleaning and shaping procedure. The healing was evaluated after 6 months by periapical radiographs and cone beam computed tomography. The comparison between obtained images after the experimental period by the two methods was done using measures of the lesion area in mm2 with ImageTool software. The results showed the presence of chronic apical periodontitis in every inoculated teeth, with Enterococcus faecalis or mixed infection. The cleaning and shaping procedures reduced the number of bacteria of the root canals (p<0.05). The radiographic and tomographic results showed the lower diameter lesion in endodontically treated teeth than in the control group (p<0.05). The comparison between the methods showed statistical difference and greater radiolucent areas were evident in cone beam computed tomography images (p<0.05). It is possible to conclude that the bacteria Enterococcus faecalis induced chronic apical periodontitis as well as the mixed microflora; the endodontic treatment reduced the number of cultivable bacteria in a significant way, but with no relation to the radiographic healing. The treated teeth in only one session presented smaller lesions in comparison to the non-treated teeth and the lesions area in cone beam computed tomography were bigger than the areas found in periapical radiograph. The confocal microscopy and the proposed method of this study showed to be efficient to determine the bacterial ability and the distribution of bacterial nucleic acids inside the dentin tubules. There was difference between in vitro infected dentin with the in vivo infection pattern, which presents biofilm attached to the root canal walls.
236

Avaliação tridimensional das vias aéreas de pacientes submetidos à expansão maxilar cirurgicamente assistida / Tridimensional assessment of airway in patients submitted to surgically assisted rapid maxillary expansion

Rodrigues, Vitor Hugo Leite de Oliveira 27 February 2014 (has links)
Neste estudo comparamos o volume dos seios maxilares dos pacientes submetidos à expansão rápida de maxila cirurgicamente assistida (EMCA), por meio da tomografia computadorizada de feixe cônico (TCFC). Foram avaliados 10 pacientes submetidos a expansão rápida de maxila cirurgicamente assistida (EMCA) pela técnica da osteotomia Le Fort I subtotal, que possuíam tomografias pré e pós-operatórias de 180 dias. As imagens foram analisadas utilizando software Dolphin Imaging® (versão 11.0.03.32) que permite a avaliação do espaço aéreo, delimitando-se áreas de interesse e realizando o calculo do volume correspondente. As imagens dos seios maxilares direito (SMD) e esquerdos (SME) foram analisadas nas tomografias pré e pós-operatórias. A média das medidas de volume foi de 13,760mm³ para o SMD e 14,499mm³ no SME, nas imagens pré-operatórias e de 14,779mm³ para o SMD e 14,435mm³ para o SME, nas pós-operatórias. Os volumes pré e pós-operatórios foram avaliados estatisticamente através do teste t pareado para significância maior que 0,05. Após as cirurgias, a média de volume dos SMD apresentou um aumento significante. Este aumento também foi observado nos SME, porem não foi estatisticamente significante. A partir destes resultados, é possível concluir que existe influencia da EMCA sobre o volume dos seios maxilares. / The aim of this study was to compare the volume of the maxillary sinuses of patients undergoing surgically assisted rapid maxillary expansion (SARME), by cone beam computed tomography (CBCT). Were evaluated 10 patients submitted to surgically assisted rapid maxillary expansion (SARME) by the technique of subtotal Le Fort I osteotomy, which had pre and postoperative CT scans of 180 days. The images were analyzed using Dolphin Imaging® (version 11.0.03.32) software that enables the assessment of airspace, delimiting up areas of interest and performing the calculation of the corresponding volume. The images of the right maxillary sinus (RMS) and left (LMS) were analyzed in the pre -and postoperative CT scans. The average measure of volume was 13.760mm³ for the RMS and 14.49mm³ in the LMS, for the preoperative images and 14.779mm³ for the RMS and 14.435mm³ for the LMS, in postoperative. The pre-and postoperative volumes were evaluated statistically by the \"t\" test. After surgery, the mean volume of RMS showed a significant increase. This increase was also observed in LMS, however it was not statistically significant. From these results, we conclude that there SARME influence on the volume of the maxillary sinuses.
237

Performance de diferentes métodos de instrumentação radicular em dentes decíduos humanos e artificiais avaliado pela tomografia computadorizada por feixe cônico / Performance of different methods of root canal instrumentation in natural and artificial primary teeth evaluated by cone beam computed tomography

Mello-Moura, Anna Carolina Volpi 10 August 2011 (has links)
No intuito de avaliar novas possibilidades de instrumentação radicular em dentes decíduos, o objetivo do presente estudo foi avaliar a performance de três diferentes métodos, manual e mecanizados, utilizando tomografia computadorizada por feixe cônico (TCFC). As técnicas utilizadas foram manual (MAN), rotatória com o sistema Protaper (ROT) e oscilatória com o sistema EndoEZE (OSC). Para o segundo objetivo, as técnicas foram testadas em dentes decíduos naturais e artificiais, para que também se pudesse avaliar a diferença entre a performance dos métodos nesses dois tipos de dentes. Após o acesso endodôntico inicial, imagens padronizadas foram realizadas em aparelho de TCFC (sistema iCat), com cortes sagital, coronal e axial. Após a instrumentação dos dentes pelos diferentes métodos, novas imagens foram realizadas. Avaliações quantitativas foram feitas medindo-se nas imagens axiais dos canais radiculares, a espessura das paredes e área do canal, em três diferentes regiões: terços cervical, médio e apical. Três desfechos foram considerados após instrumentação: desvio para a parede de risco, descentralização do canal e diferença na área do canal antes e após a instrumentação. Os valores foram comparados com análise de variância e teste de Tukey, ou com testes não paramétricos. Não houve diferença no desvio entre os métodos para os dentes anteriores artificiais e naturais. Nos posteriores naturais, entretanto, a técnica MAN apresentou maior desvio no terço cervical (p<0,05). Com relação as áreas do canal, para os dentes anteriores, o método ROT e OSC apresentaram maior desgaste que o MAN nos terços cervical e médio, mas no terço apical o OSC e o MAN foram semelhantes (p > 0,05). Para os posteriores, o método ROT apresentou um desgaste estatisticamente maior do que os demais apenas no terço apical (p<0,05). Análises qualitativas do padrão de desgaste de cada método de instrumentação radicular foram realizadas e representadas em gráficos e imagens obtidas pela TCFC. Avaliando as imagens, o padrão anatômico de todos os canais mostrou uma área maior da cervical e menor na apical. O método MAN apresentou uma tendência de preservar a anatomia inicial do canal em todos os terços. Já o ROT apresentou expressiva alteração no perfil anatômico em todos os terços e o método OSC atuou com maior expressão nas regiões cervical e média, comparado à região apical. Os dentes artificiais apresentaram similaridade de forma e radiopacidade com os dentes naturais, mas apresentaram resultados diferentes nos diversos desfechos, limitando seu uso como substitutos dos dentes naturais em pesquisas. Em conclusão, o método MAN apresenta boa performance na instrumentação radicular de dentes decíduos, mas o sistema oscilatório seria a melhor opção para obter as vantagens da instrumentação mecanizada. Em relação aos modelos de dentes artificiais utilizados, ainda necessitam ser aperfeiçoados para substituírem os dentes naturais nas pesquisas. / In order to appraise new options of root canal instrumentation in primary teeth, the aim of the present study was to evaluate the performance of three different methods, manual and mechanical, using cone beam computed tomography (CBCT). The techniques tested were manual (MAN), rotatory with Protaper system (ROT) and oscillatory with EndoEZE system (OSC). For the second objective, the techniques were assessed in natural and artificial primary teeth, in order to evaluate the difference in the performance of the methods in these types of teeth. After initial endodontic access, standardized scans were obtained by CBTC (iCat system), with sagittal, coronal and axial planes. After the root canal instrumentation of teeth with different methods, new images were achieved. Quantitative evaluations were performed measuring the thickness of root canal wall and canal area in the axial images of root canals, at three different places: coronal, middle and apical thirds. Three outcomes were considered after the instrumentation: canal transportation towards the side of root resorption, centering ability and difference in canal area before and after the instrumentation. The values were compared using ANOVA and Tukey test, or with non-parametric tests. There were no differences among the methods used in both natural and artificial anterior teeth concerning the canal transportation. In the natural posterior teeth, however, the MAN technique showed greater canal transportation towards the size of root resorption in the coronal third (p < 0.05). With regard to the canal area, for the anterior teeth, the ROT and OSC methods presented higher increase in canal area than the MAN in coronal and middle thirds, but in the apical third, OSC and MAN were similar (p > 0.05). In posterior teeth, the ROT method showed statistically higher increase in canal area than the other methods only in the apical third. Qualitative analysis of the shaping patterns of each root canal instrumentation method were carried out and presented in graphics and images obtained with CBCT. After evaluating the images, the shaping pattern of all root canals showed a larger area in the coronal and smaller in apical third. The MAN method tended to preserve the baseline anatomy of the root canal in all areas. The ROT method, on the other hand, presented more significant changes in the anatomical shaping in all thirds, and the OSC method showed higher increase in canal area in the coronal and middle thirds, compared to the apical third. The artificial teeth are very similar to natural teeth in their anatomical shape and radiopacity, but they yielded different results in several of the outcomes, which limits their use as substitute of natural teeth for research purpose. In conclusion, the MAN method presents good performance for root canal instrumentation in primary teeth, but the OSC system would be the best option to achieve the advantages of mechanical instrumentation. Concerning the artificial teeth used, some properties still need to be improved in order to substitute natural teeth for research purposes.
238

Avaliação do tecido ósseo de sítios implantares em rebordos maxilares por meio de métodos radiográficos e da análise histomorfométrica / Assessment of the bone tissue of implant sites in maxillary ridges with radiographic methods and histomophometric analysis

Côrtes, Arthur Rodriguez Gonzalez 11 June 2014 (has links)
Um dos principais fatores que influencia os resultados da terapia de implantes dentários é a densidade do osso alveolar. A sua avaliação permitiria a predição do torque de inserção do implante levando a um planejamento preciso do tratamento. O presente estudo de coorte teve como objetivo definir e correlacionar características radiográficas e morfológicas do osso, e sua influencia no torque de inserção. Foram analisados dados demográficos, radiografias panorâmicas e tomografias computadorizadas por feixe cônico (TCFC) de um total de 25 pacientes que receberam 31 implantes. Amostras ósseas retiradas dos sítios implantares foram avaliadas com densitometria óssea, micro-tomografia computadorizada, e histomorfometria. A análise de escala de cinzas avaliada com a TCFC foi fortemente correlacionada com a microtomografia computadorizada (r=0,504, p=0,004) e com a histomorfometria (r=0,795, p=0,001). No entanto, os resultados da correlação de Spearman mostraram que o torque máximo de inserção foi fortemente correlacionado com a espessura cortical do rebordo (r=0,609, p=0,001). Os resultados indicam que o torque de inserção é influenciado principalmente pela camada cortical do osso alveolar. O trabalho propõe ainda uma classificação clínica de predição de torque, baseada em resultados de sensitividade e especificidade da combinação de variáveis diferentes. A TCFC de 14-bit foi indicada como confiável para avaliar a densidade do tecido ósseo alveolar através da escala de cinzas. / A main factor influencing dental implant therapy outcomes is the alveolar bone density. Its assessment would allow for prediction of implant insertion torque (IT), leading to a precise treatment planning. The present cohort study aimed to define and correlate imaging and morphometric bone features influencing IT. Demographics, panoramic radiographs and cone beam computed tomographic (CBCT) scans of a total of 25 patients receiving 31 implants were analyzed. Bone samples retrieved from implant sites were assessed with dual x-ray absorptiometry, micro-computed tomography, and histomorphometry. Grayscale analysis using CBCT was strongly correlated with micro-computed tomography and with histomorphometric analysis (r=0.795, p=0.001). However, Spearmans correlation results showed that peak IT was strongly correlated with ridge cortical thickness (r=.609, p=.001). These results indicate that IT is mainly influenced by the amount of alveolar cortical bone layer. This work further propose a clinical classification for IT prediction, based on findings of sensitivity and specificity of the combination of different variables. 14-bit CBCT was indicated as reliable to assess alveolar bone density using grayscale analysis.
239

Análise da distribuição das tensões nas estruturas de suporte de overdentures, rebordo residual e implantes, com sistema de conexão de coroas cônicas (Syncone-Dentsply). / Analysis of the tensions distribution in the structures of overdentures support, residual alveolar ridge and implants, with connection of conical crowns system (Syncone-Dentsply)

Guariglia, Ana Cristina Aurora Rosa Perasso 22 March 2007 (has links)
O sistema de osseointegração desenvolvido por Branemark revolucionou o campo das reabilitações protéticas, incentivando os profissionais a indicar e realizar próteses do tipo overdentures. Estes dispositivos representam uma ótima alternativa para solucionar os problemas dos pacientes desdentados, insatisfeitos por diversos fatores. Várias são as associações entre os implantes e os sistemas de conexões empregados em overdentures. A literatura e a prática clínica fazem observar que na dependência do sistema de conexão empregado, há uma diferença no comportamento biomecânico, realizado por este conjunto: prótese/implante/conexão. Desta forma, é importante analisar como as tensões se distribuem sobre as estruturas que suportam estas cargas, uma vez que não existe o ligamento periodontal ao redor dos implantes que promove o mecanismo fisiológico, natural nos dentes. Assim, o objetivo desta investigação foi de avaliar, com o auxílio do método fotoelástico, o comportamento da distribuição das tensões em sobredentaduras (overdentures), suportadas por quatro implantes Ankylos®/ Dentsply®, utilizando-se o sistema protético de conexão de coroas cônicas Syncone®/ Dentsply®, onde se comparou duas formas de distribuição dos implantes, na primeira (CPM1) os implantes foram posicionados nas regiões de incisivos centrais e pré-molares e o segundo (CPM2) os implantes estavam posicionados nas regiões de caninos e pré-molares. Os modelos receberam cargas de forma crescente de 0,0 a 9,0 kg e, as tensões resultantes nas estruturas de suporte, foram analisadas fotoelasticamente. De acordo com a metodologia empregada nesta pesquisa, somos levados a concluir que: 1) Quando se associa o sistema Syncone® com overdenture ou sobredentadura, apoiada e retida sobre quatro implantes, sendo 2 localizados na região de incisivos centrais e 2 situados, diametralmente opostos, na região de segundos pré-molares na mandíbula - CPM1 - o rebordo residual é quem recebe a maior quantidade de tensões em relação aos implantes; 2) Quando se associa o sistema Syncone® com overdenture ou sobredentadura, apoiada e retida sobre 4 implantes, dispostos 2 a 2, bilateralmente e diametralmente opostos, nas regiões de caninos e pré-molares, na mandíbula (CPM2), as maiores tensões são transmitidas ao rebordo residual, sendo que os implantes suportes resultam mais preservados; 3) Comparativamente, o CPM2, aparenta ter transmitido menores tensões aos implantes que o CPM1; 4) Os implantes são preservados quanto à ocorrência de uma sobrecarga, durante a máxima intercuspidação dos arcos dentários, quando se emprega o sistema Syncone® associado à overdenture ou sobredentadura. / The osseo-integrated system develop by Branemark has revolutionized the prosthetic rehabilitation field, encourage the professionals to indicate and perform prostheses like overdentures. These devices represent an optimal alternative to solve the full dentures patient?s problems, dissatisfied for diverse factors. There are several associations between implants and prosthetic connectors employees for overdentures. The literature and the clinic practice may observe that according of the connection system employed, there is a difference into the biomechanical behavior, realized for this set: prostheses/implant/connection. From this forms, it is important to analyze how the tensions are distributing on the structures subject that support these loads, since it doesn\'t exist the periodontal ligament around the implants, what promotes the physiological mechanism of the natural teeth. Such, the purpose from this investigation was appraising, with the aid of the photoelastic method, the distribution way from the tensions at the overdentures, supported by four implants Ankylos®/ Dentsply, by using the prosthetic system of connection of conic crowns ? Syncone®/ Dentsply, were applied loads from 0,0 to 9,0kg, in crescent forms and, the tensions resulting on the support structures, have been analyzed by the photoelasthic method. Where two forms of distribution of the implantations were compared, first (CPM1) the implants were located at the regions of the central incisors and pre-molar, and as (CPM2) the implants were located at the regions of canines and pre-molar. The models had received loads of increasing form, from 0,0 to 9,0 kg and, the resultant tensions in the support structures, had been analyzed by the photoelastic method. In agreement with the methodology used in this research, we are led to conclude that: 1) When the overdenture is associated with Syncone® system, supported and retained by 4 implants, being 2 located in the region of central incisors and 2, diametrical opposing ones, in the region of the second pre-molar (CPM1) the residual alveolar ridge is who receives the biggest amount of tensions in relation to the implants; 2) When the overdenture is associated with Syncone® system, supported and retained by 4 implants, bilaterally and diametrical opposing ones, in the regions of canine and pre molar (CPM2), the biggest tensions were transmitted to the residual alveolar ridge, being the implants supports resulted more preserved; 3) Comparatively, the CPM2, seems to have transmitted less tensions to the implants than the CPM1; 4) The implants were preserved as the occurrence of an overload, during the maximum intercuspidação of the dental arcs, when the overdenture associated with Syncone® system has been used.
240

Mandible and Skull Segmentation in Cone Bean Computed Tomography Data / Segmentação da mandíbula e o crânio em tomografia computadorizada de feixe cônico

Oscar Alonso Cuadros Linares 18 December 2017 (has links)
Cone Beam Computed Tomography (CBCT) is a medical imaging technique routinely employed for diagnosis and treatment of patients with cranio-maxillo-facial defects. CBCT 3D reconstruction and segmentation of bones such as mandible or maxilla are essential procedures in orthodontic treatments. However, CBCT images present characteristics that are not desirable for processing, including low contrast, inhomogeneity, noise, and artifacts. Besides, values assigned to voxels are relative Hounsfield Units (HU), unlike traditional Computed Tomography (CT). Such drawbacks render CBCT segmentation a difficult and time-consuming task, usually performed manually with tools designed for medical image processing. We introduce two interactive two-stage methods for 3D segmentation of CBCT data: i) we first reduce the CBCT image resolution by grouping similar voxels into super-voxels defining a graph representation; ii) next, seeds placed by users guide graph clustering algorithms, splitting the bones into mandible and skull. We have evaluated our segmentation methods intensively by comparing the results against ground truth data of the mandible and the skull, in various scenarios. Results show that our methods produce accurate segmentation and are robust to changes in parameter settings. We also compared our approach with a similar segmentation strategy and we showed that it produces more accurate segmentation of the mandible and skull. In addition, we have evaluated our proposal with CT data of patients with deformed or missing bones. We obtained more accurate segmentation in all cases. As for the efficiency of our implementation, a segmentation of a typical CBCT image of the human head takes about five minutes. Finally, we carried out a usability test with orthodontists. Results have shown that our proposal not only produces accurate segmentation, as it also delivers an effortless and intuitive user interaction. / Tomografia Computadorizada de Feixe Cônico (TCFC) é uma modalidade para obtenção de imagens médicas 3D do crânio usada para diagnóstico e tratamento de pacientes com defeitos crânio-maxilo-faciais. A segmentação tridimensional de ossos como a mandíbula e a maxila são procedimentos essências em tratamentos ortodônticos. No entanto, a TCFC apresenta características não desejáveis para processamento digital como, por exemplo, baixo contraste, inomogeneidade, ruído e artefatos. Além disso, os valores atribuídos aos voxels são unidades de Hounsfield (HU) relativas, diferentemente da Tomografia Computadorizada (TC) tradicional. Esses inconvenientes tornam a segmentação de TCFC uma tarefa difícil e demorada, a qual é normalmente realizada por meio de ferramentas desenvolvidas para processamento digital de imagens médicas. Esta tese introduz dois métodos interativos para a segmentação 3D de TCFC, os quais são divididos em duas etapas: i) redução da resolução da TCFC por meio da agrupamento de voxels em super-voxels, seguida da criação de um grafo no qual os vértices são super-voxels; ii) posicionamento de sementes pelo usuário e segmentação por algoritmos de agrupamento em grafos, o que permite separar os ossos rotulados. Os métodos foram intensamente avaliados por meio da comparação dos resultados com padrão ouro da mandíbula e do crânio, considerando diversos cenários. Os resultados mostraram que os métodos não apenas produzem segmentações precisas, como também são robustos a mudanças nos parâmetros. Foi ainda realizada uma comparação com um trabalho relacionado, gerando melhores resultados tanto na segmentação da mandíbula quanto a do crânio. Além disso, foram avaliadas TCs de pacientes com ossos faltantes e quebrados. A segmentação de uma TCFC é realizada em cerca de 5 minutos. Por fim, foram realizados testes com usuarios ortodontistas. Os resultados mostraram que nossa proposta não apenas produz segmentações precisas, como também é de fácil interação.

Page generated in 0.0279 seconds