• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 454
  • 143
  • 57
  • Tagged with
  • 644
  • 265
  • 177
  • 147
  • 78
  • 68
  • 65
  • 59
  • 57
  • 53
  • 50
  • 49
  • 49
  • 45
  • 45
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Etude et développement de capteurs / effecteurs filamentaires de faibles diamètres intégrables dans des structures textiles / Study and development of low diameter filament sensors / effectors for textile instrumentation

Kechiche, Mohamed Bouraoui 08 November 2012 (has links)
Ces travaux concerne le développement de capteurs/effecteurs piézoélectrique et pyroélectrique de faible diamètre intégrable dans des structures textiles par exemple les tissus, ce qui permet soit d’avoir différentes informations sur le comportement mécanique et de température de ces structures (piézoélectricité directe) ou bien de changer les propriétés mécaniques de ces structures (piézoélectricité inverse), ce qui permettrait d’avoir des tissus à contention variable.A ce jour, sur le marché il n’existe pas de capteurs/effecteurs filamentaires piézoélectriques et/ou pyroélectriques flexibles de faibles diamètres intégrables dans les structures textiles. Les instrumentations des structures textiles qui existent se font par le biais de filaments résistifs agissant comme résistances entrecroisées qui permettent seulement d’avoir une information sur la localisation d’une pression sur ces structures textiles. Le but ces travaux est de remédier aux inconvénients des procédés connus ci-dessus. Ce but est atteint grâce à la fabrication de câbles filamentaires à l’aide d’un procédé de filage par voie fondue.Ces composites filamentaires sont caractérisé puis polariser avant de les introduire dans différents textiles par exemple les tissus, ce qui permet soit d’avoir différentes informations sur le comportement mécanique et de température de ces structures (capteurs de déformations et de température) ou bien de changer leurs propriétés mécaniques (effecteurs).Ces travaux ont été brevetés par la cellule Conectus Alsace et ils ont été sélectionnés pour le second prix International Théophile Legrand de l’innovation textile 2012. / The objective of this work is the development of composite filaments with piezoelectric and pyroelectric properties. These composite filaments will be used as sensors or effectors into textile structures (e.g weaving structures). The instrumentation of textile structures with piezoelectric composite filaments (sensors) will give information about the deformations of these structures when they are submitted to stresses. If we focus on the pyroelectric properties, this integration will allow detection of temperature variation of the operating environment. By using inverse piezoelectricity (effectors), we could change mechanical properties of textiles structures. The decision to develop this type of composites filaments was take due to the literature review which shows that composite filamentous sensors or effectors does not exist commercially. The objective of this work was achieved through the development of ferroelectric composite filament by using a melt spinning process. These composite was constituted by a portion of ferroelectric copolymer P(VDF-TrFE), an inner conductive core acting as an inner electrode and an outer conductive layer serving as an outer electrode These composite filaments were characterized with mechanical and rheological tests before being polarized by an alternating field. Then we integrate them into weaving structures using an industrial weaving machine. The result of the stressing of this structure was a variation of the field across the composite electrodes This work has been patented with the help of Conectus Alsace and it was selected for the second International Award Théophile Legrand for Textile Innovation 2012.
182

Développement d'une instrumentation embarquée pour le contrôle de dermes équivalents en culture / Development of embedded system for the control of cultured equivalent dermis

Yusifli, Elmar 18 December 2017 (has links)
La peau est un organe capable de se régénérer et de cicatriser. Elle constitue la première barrière de protection de notre organisme contre les agressions physico-chimiques extérieures. Depuis plusieurs décennies des recherches ont été menées pour maîtriser la culture du derme pour plusieurs applications telles que la greffe des grands brulés. L’aspect technologique de ce domaine a fait l’objet de plusieurs travaux. Dans les années 2000, l'équipe de notre laboratoire a proposé la méthode de culture du derme associée à des microsystèmes en silicium. C’est l’unique méthode actuelle qui permet la mesure des forces isométrique du derme équivalent lors de sa culture.Dans une première étude, nous avons proposé des nouvelles méthodes de mesure des forces isométriques qui s’exercent dans des peaux reconstruites en culture entre deux lames de silicium afin de fabriquer un bio-dispositif miniaturisé à faible coût. Ainsi, les dimensions optimales ont été calculées et des nouvelles lames ont été fabriquées. L’optimisation que nous avons retenue est relative à l’amélioration de la sensibilité de la mesure des forces. Afin de quantifier le fléchissement de lames due aux forces isométriques appliquées par le derme en culture, nous avons opté pour la mesure des déplacements des lames sous l’effets des forces isométriques, à l’aide d’ondes acoustiques de surface (SAW). Ce choix se justifie par la simplicité de l’intégration des transducteurs interdigités qui génèrent les ondes acoustiques, de la possibilité d’utiliser une interrogation sans fils et la réalisation physique de l’intercorrélation des ondes générées.A l’aide de simulation nous avons identifié les déformations des ondes et les écarts de fréquence qu’elles provoquent. En effet, la dissymétrie de la courbe d’intercorrélation des signaux transmis et reçus, par les transducteurs interdigités, est intiment liée à l’écart de fréquence de l’onde reçue. Nous avons démontré que le fléchissement engendre bien la dissymétrie dans l’axe du temps qui peut être mesurée plus précisément dans les limites d‘échantillonnage. Deux démonstrateurs sont modélisés et fabriqués dans la salle blanche afin de valider l’instrumentation et le principe de transduction d’un signal chirpé avec une onde acoustique de surface. Les résultats obtenus montrent que la méthode de mesure à l’aide d’une onde acoustique nous permet de faire de mesure de force mais dans une gamme d’intensité plus élevée que celle attendue. Par la suite, nous avons étudié la méthode de mesure de forces par les capteurs à base de piézorésistances. Sachant que la technique est basée sur la variation de résistivité du matériau déformé, nous avons décidé de replacer les grilles de lame prévue pour l’accrochage du derme en culture par le matériau piézorésistif implanté sur les micro poutres. Afin d’améliorer la résolution de détection de faibles forces une série de calcul et de simulations de la position et les dimensions du matériau piézorésistif et des micropoutres sont effectués et présentés. Une autre étude que nous avons menée en parallèle concerne le développement d’une instrumentation embarquée permettant de suivre la croissance du derme en culture basé sur un système de vision. Vu les conditions strictes de notre cahier de charges qui exigeait la portabilité et l’autonomie de système final, nous avons prévu le développement d’un système de vision embarqué basé sur un module de caméra et une carte FPGA. La caméra à haute définition montée sur le système de boite de culture finale avec un objectif permet de prendre des images de fluorescences des cellules en culture. / The skin is an organ which can regenerate and heal. It is the first shield of protection of our body against external physico-chemical aggression. For several decades, researches have been conducted to control the dermis culture for several applications such as grafting large burns. The technological aspect of this area has been the subject of several works. In the 2000s, the team of our laboratory proposed the dermis culture method associated with silicon microsystems. This is the only current method that allows the measurement of isometric forces of the equivalent dermis during its culture.In a first stage of study, in order to produce a miniaturized and low-cost bio-device, we proposed new methods to measure isometric forces in reconstructed skins in culture between two silicon beams. Thus, the optimal dimensions were calculated and new beams were fabricated. The chosen optimization is related to improve the sensitivity of the force measurement. To quantify the deflection of the beams due to the isometric forces applied by the dermis in culture, we opted for the measurement of the displacements of the beams under the influence of the isometric forces by using surface acoustic waves (SAW). This choice is justified by the simplicity of the integration of the interdigital transducers (IDT) that generate the SAW, the possibility of using a wireless interrogation and the physical realization of the cross-correlation of the generated waves.Using simulation, we have identified the frequency deviations caused by wave deformations. Indeed, the dissymmetry of the cross-correlation curve of the signals generated and received by IDT is closely related to the frequency deviation of the received wave. We have evidenced that the beam deflection generates the dissymmetry in the time axis which can be measured more precisely within the limits of sampling. Two demonstrators were designed and manufactured in the clean room to validate the instrumentation and the principle of transducing a chirped signal with a SAW. The obtained results show that the proposed SAW-based force measuring method allows us to measure force, but in a higher intensity range than expected. Subsequently, we studied the method of force measurement by piezoresistors. Considering that the technique is based on the variation of resistivity of the deformed material, we decided to replace the silicon grids provided for the attachment of the dermis in culture by the piezoresistive material implanted on the silicon micro-beams. To improve the low-resolution detection, a series of calculations and simulations of the positions and the dimensions of the piezoresistive material and the micro-beams have been carried out and presented. Another study that we conducted in parallel concerns the development of an on-board instrumentation to monitor the growth of the dermis in culture based on a vision system. Considering of the strict conditions of our specifications that required the portability and autonomy of the final system, we developed an embedded vision system based on a camera module and a FPGA card. The high definition camera mounted on the system of final culture box with a lens allows to take fluorescence images of cells in culture.
183

Capteur à fibre optique à gradient d'indice inversé basé sur la résonance plasmon de surface : applications à la détection d'espèces chimiques

Bardin, Fabrice 10 December 2001 (has links) (PDF)
Ce mémoire présente l'étude d'un capteur chimique à fibre optique à gradient d'indice inversé basé sur la résonance de plasmons de surface. Des dispositifs optiques à prisme ou mettant en jeu des fibres optiques classiques en silice utilisant cette technique de mesure sont déjà commercialisés. L'objectif de notre travail a été de caractériser théoriquement et expérimentalement un nouveau type de fibre optique permettant d'accroître les performances de ce capteur et d'en simplifier l'instrumentation. Un état de l'art des capteurs à plasmons de surface est présenté. Les structures basées sur une fibre optique (unimodale, multimodale) font l'objet d'une présentation détaillée mettant en évidence les caractéristiques des montages employés ainsi que leurs performances respectives. Nous avons cherché à déterminer le profil d'indice de réfraction du cœur de la fibre rendant les angles d'incidence à l'interface cœur-gaine quasiment égaux quels que soient les rayons se propageant dans la fibre. Ceci a été réalisé en utilisant une source lumineuse ponctuelle monochromatique positionnée dans l'axe et à une distance définie de l'entrée de la fibre. Le profil idéal présente un gradient d'indice inversé très proche d'un profil parabolique inversé pour lequel l'indice est minimal au centre du cœur de la fibre. Une description des caractéristiques de cette fibre comprenant l'étude de la propagation des rayons a été réalisée. Le phénomène de plasmon de surface est ensuite décrit, de manière générale puis ses conditions d'excitation dans la fibre employée sont étudiées. Une étude expérimentale et théorique a été menée sur les paramètres les plus influents du capteur (nature et épaisseur du métal, position de la source ...). La présentation de deux applications pratiques (détection de traces de toluène dans un milieu aqueux et étude en temps réel du mécanisme de formation d'une monocouche auto-assemblée) montre les champs d'applications du dispositif optique simple développé.
184

Development of a double-sided ladder for tracking in high-energy physics / Développement d'une échelle double face pour la trajectométrie en physique des hautes énergies

Boitrelle, Benjamin 13 February 2017 (has links)
Le projet PLUME développe des échelles ultra-légères inspirées par le cahier des charges du détecteur de vertex pour le futur e+e- International Linear Collider (ILC). Nos travaux montrent que, pour une énergie de 350 GeV et une luminosité de 250 fb-1, l’ILC donnera accès à des états finals comme Hνν. Les modules PLUME exploitent le concept d’échelles double-face recouvertes de capteurs CMOS afin d’atteindre un budget de matière de 0,35 % en longueurs de radiation. Les tests effectués ont montré que les performances électriques des 12 capteurs intégrés sur ces échelles ne sont pas dégradées. La surface des échelles présente des déformations, mais nous avons mis au point un algorithme spécifique qui permet de corriger leurs effets lors du traitement des données. Finalement, une mesure de la longueur de radiation d’un prototype moins avancé a été réalisée avec un faisceau test au DESY. La valeur obtenue de 0,47±0,02 % en longueurs de radiation correspond au budget attendu. / The PLUME project develops ultra-light pixelated layers with specifications driven by the design of a vertex detector at the future e+e- International Linear Collider (ILC). The ILC will give access to final states like Hνν, as this work demonstrates for centre-of-mass energy 350GeV and a luminosity of 250 fb-1. PLUME devices exploit the concept of double-sided ladder spaved with thinned CMOS pixel sensors in order to reach a material budget of 0.35 % of radiation length. The present study validated that simultaneous operation of the 12 CMOS sensors integrated on such light ladders do not impact their electrical behaviour. Surface deformations were observed but a specific algorithm during the off- line analysis was proposed and successfully tested to preserve the native sensor spatial resolution. Finally, a measurement of the material budget of a less advanced ladder prototype has been performedat DESY test beam and yield 0.47±0.02 % of radiation length, matching the expected value.
185

Principes alternatifs pour la détection de masse ultime via la dynamique non linéaire de capteurs résonants M/NEMS / Alternative principles for ultimate mass detection via the nonlinear dynamics of M/NEMS resonant sensors

Nguyen, Van-Nghi 11 December 2013 (has links)
Les capteurs résonants de type M/NEMS sont largement utilisés dans l’environnement biologique pour la mesure de masse de biomolécules en raison de leur grande précision combinée à une taille réduite. Classiquement, la détection et la quantification se basent sur le décalage fréquentiel induit par la masse ajoutée. Toutefois, ce décalage devient très faible et difficile à distinguer du bruit de mesure lorsque les masses considérées sont très petites. Il est théoriquement possible de gagner encore un ou plusieurs ordres de grandeur en résolution avec ces méthodes fréquentielles en diminuant encore les tailles et/ou en augmentant le rapport signal sur bruit, c’est-à-dire en actionnant de manière plus importante les résonateurs. Mais, dans ces conditions, les nanorésonateurs ont un comportement très fortement non-linéaire, source d’instabilités et de mixage de bruit basses et hautes fréquences susceptibles de dégrader la fiabilité et la précision des mesures. C’est pourquoi cette thèse a pour objectif de définir des principes de détection alternatifs basés sur l’exploitation des phénomènes non-linéaires, tels que les comportements hystérétiques et les bifurcations des courbes de réponse en fréquence. Pour cela, un modèle réduit de micro/nano-poutre résonante avec actionnement électrostatique est considéré. Les résultats numériques montrent que les brusques sauts d’amplitude à proximité des points de bifurcation permettent la détection de masses très faibles. Contrairement à la détection fréquentielle, ces sauts sont d’autant plus grands que la masse additionnelle est petite, ce qui rend cette technique particulièrement intéressante. De plus, le seuil de détection peut être ajusté avec la valeur de la fréquence de fonctionnement. Un mécanisme de réinitialisation est toutefois indispensable pour rendre la détection à nouveau possible après un saut d’amplitude. Afin d’automatiser la réinitialisation et ainsi permettre la détection en temps réel, un concept totalement innovant de détection de masse par balayage en fréquence des cycles d’hystérésis est proposé, qui permet de détecter, quantifier et localiser la masse ajoutée sur la poutre résonante. La mise en réseau de plusieurs poutres résonantes est également traitée et constitue un premier pas vers la mise en oeuvre de réseaux de milliers de capteurs. Pour cela, des architectures efficaces sont proposées et les modèles numériques sont adaptés en conséquence. Sur des configurations symétriques, l’exploitation des bifurcations de type brisure de symétrie permet là-encore d’améliorer la détection de masse. / Resonant M/NEMS mass sensors are widely used in biological environment for measuring the mass of biomolecules due to their high accuracy combined with a reduced size. Usually, the detection and the quantification are based on the frequency shift induced by an added mass. However, this shift becomes very small and difficult to distinguish from the noise of measurement as the considered masses are tiny. It is theoretically possible to increase further one or several orders of magnitude in resolution with these frequency methods by further reducing size and/or by increasing the signal-to-noise ratio, that is to say by operating more importantly the resonators. But in these conditions, the nanoresonators have a strongly nonlinear behavior, a source of instability and noise mix of low and high frequencies likely to degrade the reliability and the accuracy of measurements. Therefore, the thesis’s objective is to define alternative principles of detection based on exploiting the nonlinear phenomena, such as the hysteretic behavior and the bifurcations of frequency-response curves. To this end, a reduced model of resonant micro/nano-beam with electrostatic actuation is considered. The numerical results show that the sudden jumps in amplitude close to bifurcation points allow the detection of very small masses. Unlike the frequency detection, the smaller the added mass, the larger the increase of the jump, which makes this technique particularly interesting. In addition, the detection threshold can be adjusted with the value of the operating frequency. However, a mechanism of reinitialization is mandatory to make the detection possible again after a jump in amplitude. In order to automate the reinitialization and allow the detection in real-time, a completely innovative concept of mass detection by the frequency sweep of the hysteretic cycles is proposed to detect, quantify and locate the added mass on the resonant beam. An array of several resonant beams is also considered and constitutes a first step toward the implementation of arrays of thousands of sensors. Efficient architectures are proposed for this purpose and the numerical models are adapted accordingly. On symmetric configurations, exploiting the bifurcations of symmetry-breaking type allows here again to improve the mass detection.
186

Developing ultrasensitive and CMOS compatible ISFETs in the BEOL of industrial UTBB FDSOI transistors / Développement d'ISFET ultrasensibles et compatibles CMOS dans le BEOL des transistors industriels UTBB FDSOI

Ayele, Getenet Tesega 11 April 2019 (has links)
En exploitant la fonction d’amplification intrinsèque fournie par les transistors UTBB FDSOI, nous avons présenté des ISFET ultra sensibles. L'intégration de la fonctionnalité de détection a été réalisée en back end of line (BEOL), ce qui offre les avantages d'une fiabilité et d'une durée de vie accrues du capteur, d'une compatibilité avec le processus CMOS standard et d'une possibilité d'intégration d'un circuit diviseur capacitif. Le fonctionnement des MOSFETs, sans une polarisation appropriée de la grille avant, les rend vulnérables aux effets de grilles flottantes indésirables. Le circuit diviseur capacitif résout ce problème en polarisant la grille avant tout en maintenant la fonctionnalité de détection sur la même grille par un couplage capacitif au métal commun du BEOL. Par conséquent, le potentiel au niveau du métal BEOL est une somme pondérée du potentiel de surface au niveau de la grille de détection et de la polarisation appliquée au niveau de la grille de contrôle. Le capteur proposé est modélisé et simulé à l'aide de TCAD-Sentaurus. Un modèle mathématique complet a été développé. Il fournit la réponse du capteur en fonction du pH de la solution (entrée du capteur) et des paramètres de conception du circuit diviseur capacitif et du transistor UTBB FDSOI. Dans ce cas, des résultats cohérents ont été obtenus des travaux de modélisation et de simulation, avec une sensibilité attendue de 780 mV / pH correspondant à un film de détection ayant une réponse de Nernst. La modélisation et la simulation du capteur proposé ont également été validées par une fabrication et une caractérisation du capteur de pH à grille étendue avec validation de son concept. Ces capteurs ont été développés par un traitement séparé du composant de détection de pH, qui est connecté électriquement au transistor uniquement lors de la caractérisation du capteur. Ceci permet une réalisation plus rapide et plus simple du capteur sans avoir besoin de masques et de motifs par lithographie. Les capteurs à grille étendue ont présenté une sensibilité de 475 mV/pH, ce qui est supérieur aux ISFET de faible puissance de l'état de l’art. Enfin, l’intégration de la fonctionnalité de détection directement dans le BEOL des dispositifs FDSOI UTBB a été poursuivie. Une sensibilité expérimentale de 730 mV/pH a été obtenue, ce qui confirme le modèle mathématique et la réponse simulée. Cette valeur est 12 fois supérieure à la limite de Nernst et supérieure aux capteurs de l'état de l’art. Les capteurs sont également évalués pour la stabilité, la résolution, l'hystérésis et la dérive dans lesquels d'excellentes performances sont démontrées. / Exploiting the intrinsic amplification feature provided by UTBB FDSOI transistors, we demonstrated ultrahigh sensitive ISFETs. Integration of the sensing functionality was made in the BEOL which gives the benefits of increased reliability and life time of the sensor, compatibility with the standard CMOS process, and possibility for embedding a capacitive divider circuit. Operation of the MOSFETs without a proper front gate bias makes them vulnerable for undesired floating body effects. The capacitive divider circuit addresses these issues by biasing the front gate simultaneously with the sensing functionality at the same gate through capacitive coupling to a common BEOL metal. Therefore, the potential at the BEOL metal would be a weighted sum of the surface potential at the sensing gate and the applied bias at the control gate. The proposed sensor is modeled and simulated using TCAD-Sentaurus. A complete mathematical model is developed which provides the output of the sensor as a function of the solution pH (input to the sensor), and the design parameters of the capacitive divider circuit and the UTBB FDSOI transistor. In that case, consistent results have been obtained from the modeling and simulation works, with an expected sensitivity of 780 mV/pH corresponding to a sensing film having Nernst response. The modeling and simulation of the proposed sensor was further validated by a proof of concept extended gate pH sensor fabrication and characterization. These sensors were developed by a separated processing of just the pH sensing component, which is electrically connected to the transistor only during characterization of the sensor. This provides faster and simpler realization of the sensor without the need for masks and patterning by lithography. The extended gate sensors showed 475 mV/pH sensitivity which is superior to state of the art low power ISFETs. Finally, integration of the sensing functionality directly in the BEOL of the UTBB FDSOI devices was pursued. An experimental sensitivity of 730 mV/pH is obtained which is consistent with the mathematical model and the simulated response. This is more than 12-times higher than the Nernst limit, and superior to state of the art sensors. Sensors are also evaluated for stability, resolution, hysteresis, and drift in which excellent performances are demonstrated.
187

Développement d’une plateforme de détection de gaz, utilisant un capteur différentiel flexible imprimé à transducteurs micro-ondes et matériaux composites carbonés / Development of gas detection platform, using a printed flexible differential sensor with microwave transducers and carbon composite materials

Bahoumina, Prince 09 July 2018 (has links)
Depuis la révolution industrielle les niveaux des concentrations atmosphériques des gaz à effet de serre ne cessent d’augmenter provocant ainsi une accélération du réchauffement climatique. Les composés organiques volatils (COVs) contribuent non seulement à cet effet de serre mais aussi à la pollution environnementale qui a un impact négatif sur toutes les espèces vivantes de la planète. Par exemple, au cours de l’année 2012, la pollution de l'air a été à l’origine 7 millions de décès, selon l'Organisation mondiale de la santé (OMS) [1]. Très récemment, une étude médicale de la commission Lancet sur la pollution et la santé a révélé qu'en 2015 un décès sur six était lié à la pollution de l'air et de l'eau, 6,5 millions de décès dans le monde chaque année sont liés à la pollution de l'air intérieur et extérieur [2]. En effet, les COVs, très volatils et utilisés comme solvants par exemple, peuvent être indirectement à l’origine de toux, d’inconfort thoracique, de gêne douloureuse, d’essoufflement respiratoire, d’irritation nasale ou oculaire ou encore de la gorge. Ils peuvent aussi être directement toxiques ou explosifs ou encore perturbateurs de la réponse immunitaire. De plus certains d’entre eux sont classés CMR (cancérogène, mutagène et reprotoxique). Dans ces conditions une meilleure connaissance des effets liés à l’exposition aux COVs sur la santé et l’environnement est vraiment nécessaire. Cette connaissance passe également par la détection et la quantification des concentrations de COVs afin de proposer un meilleur aménagement des environnements et d'alerter les individus concernés en temps réel sur les dangers encourus. La plupart des plateformes déjà existantes ou commercialisées sont soient trop coûteuses, soient très consommatrices d'énergie, soient fonctionnelles à des températures élevées, soient instables pour la détection en temps réel ou à long terme ce qui limite la prolifération des sites de mesures. Ainsi, cette thèse s’inscrit dans le domaine des capteurs de gaz dédiés pour la détection de la pollution dans l’air. Elle porte sur le développement d’une plateforme de détection, de suivi et de quantification des composés organiques volatils (COVs) en temps réel, utilisant un capteur de gaz différentiel flexible et imprimé basé sur des transducteurs micro-ondes et des matériaux carbonés polymères composites comme couches sensibles. Le dispositif proposé vise à fournir des informations directement exploitables pour constituer à terme une plateforme de faible coût embarquée, dédiée à l’internet des objets pour faciliter la prolifération des sites de détection et de contrôle en réalisant des réseaux de capteurs communicants sans fil fonctionnant en environnements variés. / Since the Industrial Revolution, the levels of atmospheric concentrations of greenhouse gases have been increasing, causing an acceleration of global warming. Volatile organic compounds (VOCs) contribute not only to this greenhouse effect, but also to environmental pollution, which has a negative impact on all living species on the planet. For example, in the year 2012, air pollution caused 7 million deaths, according to the World Health Organization (WHO) [1]. In addition, a very recent medical study by the Lancet Commission on Pollution and Health found that one in six deaths in 2015 was related to air and water pollution [2]. Also, indoor and outdoor air pollution is linked to 6.5 million deaths worldwide each year. VOCs can indirectly cause cough, chest discomfort, painful discomfort, shortness of breath, as well as nasal, ocular or throat irritation. They can also be directly toxic or explosive or disruptive of the immune response. In addition, some of them are classified as CMR (carcinogenic, mutagenic and reprotoxic). They are very volatile and often used as solvents for example. In these conditions, a better understanding of the health and environmental effects of exposure to VOCs is necessary. Such knowledge also involves the detection and quantification of VOC concentrations in order to propose a better management of the environments and to alert people in real time of the dangers incurred. Most of the existing or commercially available platforms are either too expensive, energy intensive, high temperature functional, unstable for real-time or long-term detection, which limits the proliferation of measurement sites. This thesis is in the field of dedicated gas sensors for the detection of pollution in the air. It deals with the development of a platform for the detection, monitoring and quantification of volatile organic compounds (VOCs) in real time, using a flexible and printed differential gas sensor based on microwave transducers and composite polymeric carbon materials as sensitive layers. The proposed device aims at providing directly exploitable information such as a low-cost embedded platform dedicated to the Internet of things and which offers increasing possibilities for the proliferation of detection and control sites by realizing networks of wireless communicating sensors operating in various environments.
188

Conception d'un capteur de température, d'un récepteur LVSD et d'un générateur de charge en technologie CMOS 0,18 um pour un scanner TEP/TDM

Ben Attouch, Mohamed Walid January 2011 (has links)
La recherche en imagerie moléculaire repose beaucoup sur les performances en tomographie d'émission par positrons (TEP). Les avancées technologiques en électronique ont permis d'améliorer la qualité de l'image fournie par les scanners TEP et d'en augmenter le champ d'application. Le scanner LabPET II, en développement à l'Université de Sherbrooke, permettra d'atteindre des résolutions spatiales inégalées.La conception de ce scanner requiert une très grande densité de détecteurs de l'ordre de 39 000 sur un anneau de 15 cm de diamètre par 12 cm de longueur axiale. D'autre part, l'Université de Sherbrooke mène également des travaux en tomodensitométrie (TDM) par comptage de photons individuels. Ces travaux s'insèrent dans un programme de recherche menant à réduire par un facteur 1,5 à 10 la dose de rayon X par rapport aux doses actuelles en TDM. Un circuit intégré (ASIC) a été développé pour supporter les performances attendues en TEP et en TDM. Cependant, la très grande densité de canaux rend inadéquate la vérification externe, sur circuits imprimés (PCB), des fonctionnalités des 64 canaux d'acquisition du circuit intégré actuellement en conception. Ainsi, un générateur de charge électronique a été conçu et intégré dans l'ASIC afin de pouvoir vérifier directement sur le circuit intégré ( On-Chip ) le fonctionnement de la chaine d'acquisition. Il permettra aussi de faire les tests pour le calcul de la résolution d'énergie et de la résolution en temps intrinsèque. La communication des données avec l'ASIC se fait par une ligne différentielle afin de maximiser l'immunité des signaux contre le bruit et d'assurer la vitesse de communication voulue.La norme Low-Voltage Differential Signaling (LVDS) a été choisie pour ce type de communication. En effet, trois récepteurs LVDS, basse consommation, ont été conçus et intégrés dans l'ASIC afin de recevoir les commandes de fonctionnement de l'ASIC à partir d'une matrice de portes programmables Field-Programmable Gate Array (FPGA) et de communiquer le signal d'horloge aux différents blocs. Pour augmenter la fiabilité du traitement effectué par l'électronique frontale, une mesure en température de l'ASIC est nécessaire. Un capteur de température basé sur la boucle à délais Delay-Locked Loop (DLL) a été conçu et intégré. En effet, la mesure de la température de l'ASIC permet d'intervenir en réalisant une compensation sur les mesures et en contrôlant le système de refroidissement en cas de sur-échauffement.
189

Étude et développement d'une plateforme de détection chimique à ondes acoustiques de surface pour environnement sévère haute température

Tortissier, Gregory 22 October 2009 (has links) (PDF)
Ces travaux ont visé le développement d'une plateforme complète de détection de gaz pour environnement sévère haute température. Cette plateforme intègre un dispositif à ondes acoustiques de surface sur substrat Langasite, une résistance chauffante, une couche sensible inorganique nanostructurée et est placée dans une enceinte hermétique. Des températures de l'ordre de 450 °C ont été atteintes et des tests de cyclages ont démontré un fonctionnement reproductible en accord avec les modèles théoriques. Des tests de détection de composés organiques volatils (éthanol et toluène) ont mis en avant le fort potentiel du couplage entre dispositifs acoustiques et couches sensibles mésoporeuses présentant des seuils de détection de l'ordre de quelques ppm.
190

Développement d'un gyromètre à atomes froids de haute sensibilité fondé sur une géométrie repliée

Lévèque, Thomas 29 September 2010 (has links) (PDF)
Depuis les premières expériences de principe, l'interférométrie atomique a connu un essor important lié notamment à la maîtrise des processus de refroidissement d'atomes par laser et à l'utilisation de transitions cohérentes à deux photons pour les manipuler. Nous présentons dans ce manuscrit le développement d'un gyromètre atomique à effet Sagnac de haute sensibilité fondé sur une configuration repliée. Les choix expérimentaux réalisés lors de la conception de ce nouvel appareil ont été guidés par l'étude d'un premier prototype afin de repousser ses limites techniques. La première partie du travail a consisté en la caractérisation du premier gyromètre et à l'étude de ses performances limites liées à la fluctuation du biais introduit par les défauts de front d'onde du faisceau Raman. Cet appareil nous a également permis de mettre en place une méthode de mesure utilisant un sismomètre pour mesurer puis soustraire les accélérations parasites du signal de l'interféromètre assurant ainsi un niveau de sensibilité intéressant dans un environnement perturbé. L'étude s'est ensuite portée sur le test de nouvelles séparatrices atomiques en double-diffraction permettant d'accroître l'aire d'un interféromètre. La dernière partie de ce travail s'est concentrée sur le développement d'un nouveau prototype. Nous présentons ici les résultats préliminaires de cette expérience fondée sur une configuration à 4 impulsions Raman stimulées. Cette première caractérisation ouvre la voie à des mesures atteignant des niveaux de sensibilité inégalés pour ce type de capteurs.

Page generated in 0.053 seconds