• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 4
  • 1
  • Tagged with
  • 21
  • 16
  • 15
  • 9
  • 7
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Methodology development algorithms for processing and analysis of cardiotocograms in labor / Μέθοδοι επεξεργασίας σήματος καρδιοτοκογραφίας κατά την διάρκεια του τοκετού

Συκάς, Γρηγόρης 27 May 2014 (has links)
To develop and validate a computerised algorithm for the interpretation of the characteristics of the fetal heart rate (FHR) in labour. Materials and methods: A computerised algorithm based on wavelet transform and Fuzzy C-means algorithm was developed to assess baseline, variability, the presence of accelerations and types of decelerations. Twenty four segments of intrapartum cardiotocographs (CTG) were interpreted using the algorithm and evaluated by seven expert observers. The results compared to assess inter observer variation and agreement between the computer and experts. Results: Inter observer agreement for FHR baseline and the presence and type of decelerations was good (Interclass correlation coefficient (ICC), 0.93, 0.93 and 0.79 respectively). Conclusions: The validation of a computerised algorithm is limited by inter observer variation. The prediction of baseline and decelerations is as good as clinical observers but is more reproducible. / Η ανάπτυξη αλγορίθμων και υπολογιστικής μεθόδου για την ερμηνεία και επεξεργασία των χαρακτηριστικών του εμβρυικού καρδιακού ρυθμού.
2

O uso da cardiotocografia como método de diagnóstico da ocorrência de sofrimento fetal (hipóxia fetal) durante a vida intrauterina de fetos da raça Nelore originados por meio da técnica de transferência nuclear de células somáticas adultas - Clonagem / The use of cardiotocography as a method of diagnosis of the occurrence of fetal distress (fetal hypoxia) during intrauterine life in fetuses of Nellore generated through the technique of somatic adult cell nuclear transfer - Cloning

Nunes, Mariana Tikuma 28 August 2009 (has links)
A presente pesquisa teve a finalidade de padronizar a técnica de cardiotocografia a ser utilizada para avaliar a existência de hipóxia/sofrimento fetal durante a vida intrauterina, procurando estabelecer a partir do 7º mês da gestação os padrões de normalidade da frequência cardíaca fetal para fetos sadios e oriundos de inseminação artificial, bem como avaliar a influência da clonagem nos parâmetros obtidos no exame de cardiotocografia. Foram acompanhadas as gestações de 14 vacas, sendo os animais divididos em três grupos experimentais: Grupo de Clones Mortos composto de 5 vacas gestantes nas quais acompanhou-se a carditocografia de fetos gerados pela técnica de clonagem e nos quais a morte do bezerro ocorreu nas primeiras 36 horas de vida ; Grupo de Clones Vivos composto de 4 vacas gestantes nas quais acompanhou-se a carditocografia de fetos gerados pela técnica de clonagem e que permaneceram vivos após o nascimento; Grupo Controle - composto de 5 vacas gestantes nas quais acompanhou-se a carditocografia de fetos gerados por inseminação artificial e que deram origem a bezerros sadios. Os animais foram acompanhados por exames periódicos de cardiotocografia realizados nos seguintes momentos: 90, 60, 30, 15, 7, 6, 5, 4, 3, 2, 1 dia antes do parto e no dia do parto. Para a realização dos exames foi utilizado o aparelho de cardiotocografia da marca Philips modelo Avalon FM30,no local onde as vacas se encontravam. Os exames tiveram uma duração de 20 a 40 minutos de traçado, sendo que o transdutor de ultra-som era acomodado de forma a obter o melhor sinal cardíaco fetal. Imediatamente após o nascimento, realizou-se a avaliação da viabilidade de bezerros recém-nascidos pelo método APGAR e a observação de bezerros tingidos de amarelo em decorrência da presença de mecônio nas secreções uterinas.Através dos traçados obtidos com a cardiotocografia foram analisados os parâmetros da cardiotocografia: linha de base, acelerações transitórias, acelerações prolongadas, variabilidade, taquicardia, bradicardia e desacelerações, sendo ao final calculado o índice cardiotocométrico. Nos animais classificados como hipoativo ou inativo aplicava-se estimulação por palpação retal com beliscamento do espaço interdigital do feto com o objetivo de modificar o comportamento fetal e evitar resultados falso positivos.O exame de cardiotocografia mostrou ser eficaz na avaliação da vitalidade fetal na espécie bovina. Os valores médios e o desvio padrão da frequência cardíaca fetal basal (linha de base) em fetos hígidos foi igual a 116,4 ± 9,07 bpm. Considerou-se taquicardia uma frequência cardíaca fetal igual ou maior do que 145 bpm e bradicardia uma frequência cardíaca igual ou menor do que 90 bpm. Considerou-se normal para bovinos uma variabilidade com valores situados entre 5 e 15 bpm. Verificou-se que a presença de acelerações transitórias são indicativas de bem estar fetal, sendo que o número de acelerações transitórios consideradas como fisiológicas varia entre 1 e 5. Desacelerações são indicativos da existência de sofrimento fetal, não sendo observadas em animais hígidos. No grupo de clones mortos, existem modificações da carditocografia compatíveis com a ocorrência de sofrimento fetal/ hipóxia intrauterina. Os fetos do grupo de clones mortos apresentaram com maior frequência momentos de hipoatividade fetal do que os fetos do grupo de clones vivos e fetos do grupo controle e os fetos do grupo de clone mortos foram classificados com maior frequência como não reativos ao estímulo de beliscamento das extremidades do que os fetos do grupo controle. Os fetos do grupo de clones mortos apresentaram com mais frequência bradicardia (11,8%) do que a observada no grupo controle (0,00 %). Observou-se que no grupo de clones mortos (1,4 ± 1,6) o número de acelerações transitórias foi significativamente menor do que o observado no grupo de clones vivos (3,50 ± 2,70) e no grupo controle (2,70 ± 1,80). / This research had the purpose to standardize the technique of cardiotocography to be used to assess the presence of hypoxia / fetal distress during intrauterine life, trying to establish from the 7th month of pregnancy the normal range of fetal heart rate in healthy fetuses and from artificial insemination and cloning to evaluate the influence of the parameters obtained in the examination of cardiotocography. Were followed the pregnancies of 14 cows and animals are divided into three experimental groups: Dead Clones Group - composed of 5 pregnant cows which was accompanied the cardiotocography of fetuses generated by the technique of cloning, in which the death occurred in the calf first 36 hours of life; Living Clones Group - composed of 4 pregnant cows which is accompanied cardiotocography of fetuses generated by the technique of cloning and remained alive after the birth, control group - composed of 5 pregnant cows in which follow - the cardiotocography of fetuses generated by artificial insemination and gave rise to healthy calves. The animals were monitored by periodic assessment of cardiotocography performed in the following periods: 90, 60, 30, 15, 7, 6, 5, 4, 3, 2, 1 day before parturition and day of birth. For the examinations we used the apparatus of cardiotocography Brand Philips Avalon FM30 model, where the cows were. The tests had a duration of 20 to 40 minutes of track, and the ultrasound transducer was adjusted to obtain the best fetal cardiac signal. Immediately after birth, was held to assess the viability of newborn calves by the method APGAR and the observation of colored yellow calves due to the presence of meconium in the uterine secretions. Through cardiotocography tracings were analyzed with the parameters of cardiotocography : the baseline, acceleration transient, prolonged accelerations, variability, tachycardia, bradycardia, and deceleration modes, and the final calculated the index cardiotocométrico. In the animals classified as inactive or hypoactive stimulation was applied by rectal palpation of the interdigital space with pinch of the fetus with order to modify the behavior and prevent fetal false positives. An examination of cardiotocography has proven effective in evaluation of fetal vitality in the bovine species. The mean values and standard deviation of the baseline fetal heart rate (from baseline) in healthy fetuses was equal to 116.4 ± 9.07 bpm. Tachycardia was considered a fetal heart rate equal to or greater than 145 bpm bradycardia and a heart rate less than or equal to 90 bpm. It was considered normal for cattle variability with values between 5 and 15 bpm. It was found that the presence of transient accelerations are indicative of fetal well-being, and the number of transient accelerations considered physiological ranges between 1 and 5. Deceleration is indicative of the existence of fetal distress and is not observed in healthy animals. In the group of clones dead, there are changes in cardiotocography consistent with the occurrence of fetal distress / intrauterine hypoxia. The fetuses of the group of clones had killed more often moments of fetal hypoactivity than the fetuses of the group of clones live fetuses and the control group and the group of fetuses dead clone were classified more frequently as non-reactive to stimulation of the pinch ends of the fetuses in the control group. The fetuses of the group of dead clones showed bradycardia more often (11.8%) than that observed in the control group (0.00%). It was observed that the group of dead clones (1.4 ± 1.6) the number of transient acceleration was significantly lower than that observed in the group of live clones (3.50 ± 2.70) and the control group (2 , 70 ± 1.80).
3

"Cardiotocografia estimulada em gestações de baixo risco: estudo comparativo da resposta cardíaca fetal à estimulação vibratória e sônica" / Stimulated cardiotocography in low-risk pregnancies: comparative study of fetal cardiac response to vibratory and sonic stimulation

Souza, Adriana Cristina de 07 June 2006 (has links)
Trata-se de estudo prospectivo, comparativo da resposta da freqüência cardíaca fetal (FCF) à estimulação vibratória e sônica, quanto à amplitude e duração, em 113 fetos de gestações de baixo risco. A população estudada foi discriminada em quatro grupos: 1) 25 semanas a 28 semanas e seis dias; 2) 29 semanas a 32 semanas e seis dias; 3) 33 semanas a 36 semanas e seis dias e 4) 37 a 42 semanas. Comparando-se a amplitude e a duração da resposta da FCF na faixa três e na faixa quatro, a resposta à estimulação vibratória foi menor que a sônica. Nas faixas um e dois não houve diferença nas respostas. Conclui-se que a estimulação vibratória promove resposta fetal (FCF) menos intensa com amplitude e duração de resposta menor quando comparada à estimulação sônica em faixa de idade gestacional mais tardia / This prospective study compares the response in terms of fetal heart rate acceleration after vibratory and sonic stimulation, in a sample of 113 fetuses of low-risk pregnancies. The study population was divided into four groups according to gestational age: group 1 - 25 weeks to 28 weeks and 6 days; group 2 - 29 weeks to 32 weeks and 6 days; group 3 - 33 weeks to 36 weeks and 6 days, and group 4 - 37 to 42 weeks. Comparing the amplitude and duration of the cardioacceleratory response between group 3 and 4, the response after vibratory stimulation was lower than sonic. In the groups 1 and 2, the response was similar. The study concludes that vibratory stimulation promotes a less intense response with amplitude and duration lower than sonic stimulation in latter gestational age
4

"Cardiotocografia computadorizada em gestantes com diabetes mellitus: efeitos da glicemia capilar materna na freqüência cardíaca fetal" / Computerized cardiotocography in pregnants affected by diabetes mellitus: effects of maternal capillary glycemia in the fetal heart rate

Verbenia Nunes Costa 12 July 2006 (has links)
Os efeitos da glicemia materna na regulação da freqüência cardíaca fetal (FCF) constituem aspecto controverso na literatura, principalmente em gestações complicadas pelo diabetes mellitus. O objetivo deste trabalho foi estudar a influência da glicemia materna na FCF analisada pela cardiotocografia computadorizada. Método: Trinta e nove gestantes com diabetes mellitus pré-gestacional foram avaliadas prospectivamente na Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, no período compreendido entre julho de 2003 e fevereiro de 2005. As pacientes incluídas possuíam o diagnóstico de diabetes pré-gestacional, gestação única, idade gestacional entre 36 e 40 semanas e ausência de malformações fetais. Para a realização do estudo, cada paciente foi avaliada pela cardiotocografia computadorizada, durante uma hora, sendo analisados os seguintes parâmetros da FCF: freqüência basal, tempo para atingir os critérios de normalidade, freqüência de movimentos fetais, número de contrações uterinas, número de acelerações e desacelerações, episódios de alta e baixa variação, variação de curto prazo. Realizou-se a glicemia capilar imediatamente antes do início da cardiotocografia, 30 e 60 minutos após o começo do exame. Utilizou-se a média glicêmica para análise das relações com os achados cardiotocográficos, com os valores de corte de 100 mg/dL e 120mg/dL. Resultados: Do total de 39 pacientes analisadas, 25 (64,1%) apresentavam média glicêmica &#8805; a 100 mg/dL e 19 (48,7%) &#8805; a 120 mg/dL. A média da FCF mostrou aumento significativo nos grupos com a média glicêmica &#8805; a 100 mg/dL (p<0,05) e a 120mg/dL (p<0,05). Houve correlação positiva significativa (p<0,05 e r=0,57) da FCF com a média glicêmica no exame. Verificou-se correlação negativa significativa (p<0,05) da quantidade de acelerações transitórias acima de 10 bpm (r=-0,32) e de 15 bpm (r=-0,44) com a média glicêmica no exame. A variação de curto prazo da FCF apresentou associação significativa (p<0,05) com a média glicêmica acima de 120mg/dL. Ocorreu correlação negativa significativa (p<0,05) da variação de curto prazo da FCF (r=-0,47) com a média glicêmica no exame. Os demais parâmetros avaliados pela cardiotocografia computadorizada não mostraram diferença significativa com a média glicêmica. Conclusão: os níveis glicêmicos maternos, durante o exame, exercem influência sobre parâmetros da FCF analisada pela cardiotocografia computadorizada. / The effects of maternal glycemia over the of fetal heart rate (FHR) regulation appoint a controversial subject in the literature, mainly in pregnancies affected by diabetes mellitus. The objective of this research was to investigate the influence of maternal glycemia in the FHR indices analysed by computerized cardiotocography. Methods: Thirty nine patients with pre-gestational diabetes mellitus were examined prospectively in the Obstetrics Department of Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo- Brazil in a period of time between July of 2003 and February of 2005. The patients included had pre-gestational diabetes diagnosis, single pregnancy, gestational age between 36 and 40 weeks and absent of fetal malformations. Each patient were evaluated by computerized cardiotocography during 60 minutes, with analysis of these follow FHR parameters: basal FHR, time necessary to reach normality criteria, fetal movements rate, contraction peaks, accelerations and decelerations, episodes of high and low FHR variation, short-term FHR variation. The capillary glycemia were colleted immediately before the cardiotocography be performed, 30 and 60 minutes after the beginning of the exam. The glicemic mean level was used for analysis with the cardiotocografics results, with the cut values of 100 mg/dL and 120mg/dL. Results: From 39 patients studied, 25 (64,1%) presented glicemic mean &#8805; to 100 mg/dL and 19 (48,7%) &#8805; to 120 mg/dL. 1) The mean of FHR showed significant elevation in the groups with the glicemic mean &#8805; to 100 mg/dL and to 120mg/dl (p<0,05); 2) There was significant positive correlation (p<0,05 and r=0,57) between the FHR and the mean glicemic; 3) There was significant negative correlation (p<0,05) between the number of transitory accelerations &#8805; than 10bpm (r=-0,32) and &#8805; than 15 bpm (r=-0,44) and the mean glicemic; 4) The short-term FHR variation presented significant association (p<0,05) with the mean glicemic &#8805; 120mg/dL; 5) There was significant negative correlation (p<0,05) between short-term FHR variation (r=-0,47) and the mean glicemic. The others indices evaluated by computerized cardiotocography didn’t exhibit significant difference with the mean glicemic. Conclusions: The maternal glicemic levels during computerized cardiotocography seem to have influence over these analised FHR parameters.
5

"Cardiotocografia computadorizada em gestantes com diabetes mellitus: efeitos da glicemia capilar materna na freqüência cardíaca fetal" / Computerized cardiotocography in pregnants affected by diabetes mellitus: effects of maternal capillary glycemia in the fetal heart rate

Costa, Verbenia Nunes 12 July 2006 (has links)
Os efeitos da glicemia materna na regulação da freqüência cardíaca fetal (FCF) constituem aspecto controverso na literatura, principalmente em gestações complicadas pelo diabetes mellitus. O objetivo deste trabalho foi estudar a influência da glicemia materna na FCF analisada pela cardiotocografia computadorizada. Método: Trinta e nove gestantes com diabetes mellitus pré-gestacional foram avaliadas prospectivamente na Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, no período compreendido entre julho de 2003 e fevereiro de 2005. As pacientes incluídas possuíam o diagnóstico de diabetes pré-gestacional, gestação única, idade gestacional entre 36 e 40 semanas e ausência de malformações fetais. Para a realização do estudo, cada paciente foi avaliada pela cardiotocografia computadorizada, durante uma hora, sendo analisados os seguintes parâmetros da FCF: freqüência basal, tempo para atingir os critérios de normalidade, freqüência de movimentos fetais, número de contrações uterinas, número de acelerações e desacelerações, episódios de alta e baixa variação, variação de curto prazo. Realizou-se a glicemia capilar imediatamente antes do início da cardiotocografia, 30 e 60 minutos após o começo do exame. Utilizou-se a média glicêmica para análise das relações com os achados cardiotocográficos, com os valores de corte de 100 mg/dL e 120mg/dL. Resultados: Do total de 39 pacientes analisadas, 25 (64,1%) apresentavam média glicêmica &#8805; a 100 mg/dL e 19 (48,7%) &#8805; a 120 mg/dL. A média da FCF mostrou aumento significativo nos grupos com a média glicêmica &#8805; a 100 mg/dL (p<0,05) e a 120mg/dL (p<0,05). Houve correlação positiva significativa (p<0,05 e r=0,57) da FCF com a média glicêmica no exame. Verificou-se correlação negativa significativa (p<0,05) da quantidade de acelerações transitórias acima de 10 bpm (r=-0,32) e de 15 bpm (r=-0,44) com a média glicêmica no exame. A variação de curto prazo da FCF apresentou associação significativa (p<0,05) com a média glicêmica acima de 120mg/dL. Ocorreu correlação negativa significativa (p<0,05) da variação de curto prazo da FCF (r=-0,47) com a média glicêmica no exame. Os demais parâmetros avaliados pela cardiotocografia computadorizada não mostraram diferença significativa com a média glicêmica. Conclusão: os níveis glicêmicos maternos, durante o exame, exercem influência sobre parâmetros da FCF analisada pela cardiotocografia computadorizada. / The effects of maternal glycemia over the of fetal heart rate (FHR) regulation appoint a controversial subject in the literature, mainly in pregnancies affected by diabetes mellitus. The objective of this research was to investigate the influence of maternal glycemia in the FHR indices analysed by computerized cardiotocography. Methods: Thirty nine patients with pre-gestational diabetes mellitus were examined prospectively in the Obstetrics Department of Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo- Brazil in a period of time between July of 2003 and February of 2005. The patients included had pre-gestational diabetes diagnosis, single pregnancy, gestational age between 36 and 40 weeks and absent of fetal malformations. Each patient were evaluated by computerized cardiotocography during 60 minutes, with analysis of these follow FHR parameters: basal FHR, time necessary to reach normality criteria, fetal movements rate, contraction peaks, accelerations and decelerations, episodes of high and low FHR variation, short-term FHR variation. The capillary glycemia were colleted immediately before the cardiotocography be performed, 30 and 60 minutes after the beginning of the exam. The glicemic mean level was used for analysis with the cardiotocografics results, with the cut values of 100 mg/dL and 120mg/dL. Results: From 39 patients studied, 25 (64,1%) presented glicemic mean &#8805; to 100 mg/dL and 19 (48,7%) &#8805; to 120 mg/dL. 1) The mean of FHR showed significant elevation in the groups with the glicemic mean &#8805; to 100 mg/dL and to 120mg/dl (p<0,05); 2) There was significant positive correlation (p<0,05 and r=0,57) between the FHR and the mean glicemic; 3) There was significant negative correlation (p<0,05) between the number of transitory accelerations &#8805; than 10bpm (r=-0,32) and &#8805; than 15 bpm (r=-0,44) and the mean glicemic; 4) The short-term FHR variation presented significant association (p<0,05) with the mean glicemic &#8805; 120mg/dL; 5) There was significant negative correlation (p<0,05) between short-term FHR variation (r=-0,47) and the mean glicemic. The others indices evaluated by computerized cardiotocography didn’t exhibit significant difference with the mean glicemic. Conclusions: The maternal glicemic levels during computerized cardiotocography seem to have influence over these analised FHR parameters.
6

The cost-effectiveness of foetal monitoring with ST analysis

Heintz, Emelie January 2008 (has links)
How to allocate resources in the health care sector is academically dealt with within the subject of health economics. Economic evaluations are within this area used to compare the costs and effects of medical interventions with the purpose to help decision makers decide how to allocate resources. Oxygen deficiency in the foetus during birth can lead to severe life long injuries in the child. In high-risk deliveries, it is therefore considered necessary to use foetal surveillance with a scalp electrode and the choice is between surveillance with internal cardiotocography (CTG) and surveillance with ST analysis. The standard procedure is in most hospitals currently CTG, which records the foetal heart rate and the uterine contractions. The second strategy, in this thesis referred to as ST analysis, complements CTG with foetal electrocardiography(ECG) and ST analysis. The objective of this report is to from a societal perspective determine the cost-effectiveness of using ST analysis in complicated deliveries, compared to the use of CTG alone. A cost-utility analysis was performed based on a probabilistic decision model incorporating the relevant strategies and outcomes. The costs and effects of the two different treatment strategies were compared in a decision tree. Discounted costs and quality-adjusted life-years (QALYs) were measured and simulated over a life-time perspective. The analysis resulted in an incremental effect of 0.005 QALYs for the ST analysis strategy, when compared to the CTG strategy. ST analysis was also associated with a €30 lower cost. Thus, CTG is dominated by the ST analysis strategy. The probability that ST analysis is the cost-effective alternative is high for all values of willingness-to-pay for a QALY, which means that a decision to implement the ST analysis strategy based on the results of this thesis would be surrounded by a low degree of uncertainty.
7

The cost-effectiveness of foetal monitoring with ST analysis

Heintz, Emelie January 2008 (has links)
<p>How to allocate resources in the health care sector is academically dealt with within the subject of health economics. Economic evaluations are within this area used to compare the costs and effects of medical interventions with the purpose to help decision makers decide how to allocate resources.</p><p>Oxygen deficiency in the foetus during birth can lead to severe life long injuries in the child. In high-risk deliveries, it is therefore considered necessary to use foetal surveillance with a scalp electrode and the choice is between surveillance with internal cardiotocography (CTG) and surveillance with ST analysis. The standard procedure is in most hospitals currently CTG, which records the foetal heart rate and the uterine contractions. The second strategy, in this thesis referred to as ST analysis, complements CTG with foetal electrocardiography(ECG) and ST analysis.</p><p>The objective of this report is to from a societal perspective determine the cost-effectiveness of using ST analysis in complicated deliveries, compared to the use of CTG alone. A cost-utility analysis was performed based on a probabilistic decision model incorporating the relevant strategies and outcomes. The costs and effects of the two different treatment strategies were compared in a decision tree. Discounted costs and quality-adjusted life-years (QALYs) were measured and simulated over a life-time perspective.</p><p>The analysis resulted in an incremental effect of 0.005 QALYs for the ST analysis strategy, when compared to the CTG strategy. ST analysis was also associated with a €30 lower cost. Thus, CTG is dominated by the ST analysis strategy. The probability that ST analysis is the cost-effective alternative is high for all values of willingness-to-pay for a QALY, which means that a decision to implement the ST analysis strategy based on the results of this thesis would be surrounded by a low degree of uncertainty.</p>
8

O uso da cardiotocografia como método de diagnóstico da ocorrência de sofrimento fetal (hipóxia fetal) durante a vida intrauterina de fetos da raça Nelore originados por meio da técnica de transferência nuclear de células somáticas adultas - Clonagem / The use of cardiotocography as a method of diagnosis of the occurrence of fetal distress (fetal hypoxia) during intrauterine life in fetuses of Nellore generated through the technique of somatic adult cell nuclear transfer - Cloning

Mariana Tikuma Nunes 28 August 2009 (has links)
A presente pesquisa teve a finalidade de padronizar a técnica de cardiotocografia a ser utilizada para avaliar a existência de hipóxia/sofrimento fetal durante a vida intrauterina, procurando estabelecer a partir do 7º mês da gestação os padrões de normalidade da frequência cardíaca fetal para fetos sadios e oriundos de inseminação artificial, bem como avaliar a influência da clonagem nos parâmetros obtidos no exame de cardiotocografia. Foram acompanhadas as gestações de 14 vacas, sendo os animais divididos em três grupos experimentais: Grupo de Clones Mortos composto de 5 vacas gestantes nas quais acompanhou-se a carditocografia de fetos gerados pela técnica de clonagem e nos quais a morte do bezerro ocorreu nas primeiras 36 horas de vida ; Grupo de Clones Vivos composto de 4 vacas gestantes nas quais acompanhou-se a carditocografia de fetos gerados pela técnica de clonagem e que permaneceram vivos após o nascimento; Grupo Controle - composto de 5 vacas gestantes nas quais acompanhou-se a carditocografia de fetos gerados por inseminação artificial e que deram origem a bezerros sadios. Os animais foram acompanhados por exames periódicos de cardiotocografia realizados nos seguintes momentos: 90, 60, 30, 15, 7, 6, 5, 4, 3, 2, 1 dia antes do parto e no dia do parto. Para a realização dos exames foi utilizado o aparelho de cardiotocografia da marca Philips modelo Avalon FM30,no local onde as vacas se encontravam. Os exames tiveram uma duração de 20 a 40 minutos de traçado, sendo que o transdutor de ultra-som era acomodado de forma a obter o melhor sinal cardíaco fetal. Imediatamente após o nascimento, realizou-se a avaliação da viabilidade de bezerros recém-nascidos pelo método APGAR e a observação de bezerros tingidos de amarelo em decorrência da presença de mecônio nas secreções uterinas.Através dos traçados obtidos com a cardiotocografia foram analisados os parâmetros da cardiotocografia: linha de base, acelerações transitórias, acelerações prolongadas, variabilidade, taquicardia, bradicardia e desacelerações, sendo ao final calculado o índice cardiotocométrico. Nos animais classificados como hipoativo ou inativo aplicava-se estimulação por palpação retal com beliscamento do espaço interdigital do feto com o objetivo de modificar o comportamento fetal e evitar resultados falso positivos.O exame de cardiotocografia mostrou ser eficaz na avaliação da vitalidade fetal na espécie bovina. Os valores médios e o desvio padrão da frequência cardíaca fetal basal (linha de base) em fetos hígidos foi igual a 116,4 ± 9,07 bpm. Considerou-se taquicardia uma frequência cardíaca fetal igual ou maior do que 145 bpm e bradicardia uma frequência cardíaca igual ou menor do que 90 bpm. Considerou-se normal para bovinos uma variabilidade com valores situados entre 5 e 15 bpm. Verificou-se que a presença de acelerações transitórias são indicativas de bem estar fetal, sendo que o número de acelerações transitórios consideradas como fisiológicas varia entre 1 e 5. Desacelerações são indicativos da existência de sofrimento fetal, não sendo observadas em animais hígidos. No grupo de clones mortos, existem modificações da carditocografia compatíveis com a ocorrência de sofrimento fetal/ hipóxia intrauterina. Os fetos do grupo de clones mortos apresentaram com maior frequência momentos de hipoatividade fetal do que os fetos do grupo de clones vivos e fetos do grupo controle e os fetos do grupo de clone mortos foram classificados com maior frequência como não reativos ao estímulo de beliscamento das extremidades do que os fetos do grupo controle. Os fetos do grupo de clones mortos apresentaram com mais frequência bradicardia (11,8%) do que a observada no grupo controle (0,00 %). Observou-se que no grupo de clones mortos (1,4 ± 1,6) o número de acelerações transitórias foi significativamente menor do que o observado no grupo de clones vivos (3,50 ± 2,70) e no grupo controle (2,70 ± 1,80). / This research had the purpose to standardize the technique of cardiotocography to be used to assess the presence of hypoxia / fetal distress during intrauterine life, trying to establish from the 7th month of pregnancy the normal range of fetal heart rate in healthy fetuses and from artificial insemination and cloning to evaluate the influence of the parameters obtained in the examination of cardiotocography. Were followed the pregnancies of 14 cows and animals are divided into three experimental groups: Dead Clones Group - composed of 5 pregnant cows which was accompanied the cardiotocography of fetuses generated by the technique of cloning, in which the death occurred in the calf first 36 hours of life; Living Clones Group - composed of 4 pregnant cows which is accompanied cardiotocography of fetuses generated by the technique of cloning and remained alive after the birth, control group - composed of 5 pregnant cows in which follow - the cardiotocography of fetuses generated by artificial insemination and gave rise to healthy calves. The animals were monitored by periodic assessment of cardiotocography performed in the following periods: 90, 60, 30, 15, 7, 6, 5, 4, 3, 2, 1 day before parturition and day of birth. For the examinations we used the apparatus of cardiotocography Brand Philips Avalon FM30 model, where the cows were. The tests had a duration of 20 to 40 minutes of track, and the ultrasound transducer was adjusted to obtain the best fetal cardiac signal. Immediately after birth, was held to assess the viability of newborn calves by the method APGAR and the observation of colored yellow calves due to the presence of meconium in the uterine secretions. Through cardiotocography tracings were analyzed with the parameters of cardiotocography : the baseline, acceleration transient, prolonged accelerations, variability, tachycardia, bradycardia, and deceleration modes, and the final calculated the index cardiotocométrico. In the animals classified as inactive or hypoactive stimulation was applied by rectal palpation of the interdigital space with pinch of the fetus with order to modify the behavior and prevent fetal false positives. An examination of cardiotocography has proven effective in evaluation of fetal vitality in the bovine species. The mean values and standard deviation of the baseline fetal heart rate (from baseline) in healthy fetuses was equal to 116.4 ± 9.07 bpm. Tachycardia was considered a fetal heart rate equal to or greater than 145 bpm bradycardia and a heart rate less than or equal to 90 bpm. It was considered normal for cattle variability with values between 5 and 15 bpm. It was found that the presence of transient accelerations are indicative of fetal well-being, and the number of transient accelerations considered physiological ranges between 1 and 5. Deceleration is indicative of the existence of fetal distress and is not observed in healthy animals. In the group of clones dead, there are changes in cardiotocography consistent with the occurrence of fetal distress / intrauterine hypoxia. The fetuses of the group of clones had killed more often moments of fetal hypoactivity than the fetuses of the group of clones live fetuses and the control group and the group of fetuses dead clone were classified more frequently as non-reactive to stimulation of the pinch ends of the fetuses in the control group. The fetuses of the group of dead clones showed bradycardia more often (11.8%) than that observed in the control group (0.00%). It was observed that the group of dead clones (1.4 ± 1.6) the number of transient acceleration was significantly lower than that observed in the group of live clones (3.50 ± 2.70) and the control group (2 , 70 ± 1.80).
9

"Cardiotocografia estimulada em gestações de baixo risco: estudo comparativo da resposta cardíaca fetal à estimulação vibratória e sônica" / Stimulated cardiotocography in low-risk pregnancies: comparative study of fetal cardiac response to vibratory and sonic stimulation

Adriana Cristina de Souza 07 June 2006 (has links)
Trata-se de estudo prospectivo, comparativo da resposta da freqüência cardíaca fetal (FCF) à estimulação vibratória e sônica, quanto à amplitude e duração, em 113 fetos de gestações de baixo risco. A população estudada foi discriminada em quatro grupos: 1) 25 semanas a 28 semanas e seis dias; 2) 29 semanas a 32 semanas e seis dias; 3) 33 semanas a 36 semanas e seis dias e 4) 37 a 42 semanas. Comparando-se a amplitude e a duração da resposta da FCF na faixa três e na faixa quatro, a resposta à estimulação vibratória foi menor que a sônica. Nas faixas um e dois não houve diferença nas respostas. Conclui-se que a estimulação vibratória promove resposta fetal (FCF) menos intensa com amplitude e duração de resposta menor quando comparada à estimulação sônica em faixa de idade gestacional mais tardia / This prospective study compares the response in terms of fetal heart rate acceleration after vibratory and sonic stimulation, in a sample of 113 fetuses of low-risk pregnancies. The study population was divided into four groups according to gestational age: group 1 - 25 weeks to 28 weeks and 6 days; group 2 - 29 weeks to 32 weeks and 6 days; group 3 - 33 weeks to 36 weeks and 6 days, and group 4 - 37 to 42 weeks. Comparing the amplitude and duration of the cardioacceleratory response between group 3 and 4, the response after vibratory stimulation was lower than sonic. In the groups 1 and 2, the response was similar. The study concludes that vibratory stimulation promotes a less intense response with amplitude and duration lower than sonic stimulation in latter gestational age
10

Predição de acidemia ao nascimento em gestações com dopplervelocimetria anormal e fluxo diastólico positivo das artérias umbilicais / Predicting acidemia at birth in pregnancies with abnormal but present end-diastolic flow velocity in umbilical artery

Ribeiro, Renata Lopes 09 September 2009 (has links)
No setor de Vitalidade Fetal na Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo foi conduzido estudo caso-controle com seguimento prospectivo com quarenta e seis pacientes. O objetivo desse estudo foi identificar a associação dos testes de avaliação de vitalidade fetal e acidemia ao nascimento em gestações acometidas com dopplervelocimetria anormal e fluxo diastólico positivo das artérias umbilicais. Da mesma maneira, objetivou-se avaliar a relação entre os resultados antenatais, do parto, e neonatais com a ocorrência de pH fetal inferior a 7,20. A evolução para fluxo diastólico ausente ou reverso durante o seguimento foi critério de exclusão. Os casos foram classificados em dois grupos de acordo com a presença (grupo 1), ou ausência (grupo 2) de acidemia ao nascimento (pH inferior a 7,20), por meio da gasometria arterial de cordão imediatamente após o parto. As seguintes variáveis foram submetidas à análise univariada, comparando-se os grupos 1 e 2: idade materna, síndrome hipertensiva, uso de corticóde antenatal para maturação pulmonar, idade gestacional no momento do parto e testes de avaliação de vitalidade fetal do dia do parto. As modalidades dopplervelocimétricas analisadas foram: índice de pulsatilidade do território arterial (representado pela artéria umbilical e artéria cerebral média) e venoso (índice de pulsatilidade para veias do ducto venoso). Os seguintes parâmetros das atividades biofísicas fetais foram estudados: cardiotocografia (normal e anormal), presença de desaceleração tardia, presença de desaceleração (desaceleração tardia, ou desaceleração variável de mau prognóstico, ou desaceleração prolongada), ausência ou não de movimentos respiratórios, presença ou não de oligoâmnio e classificação do escore do perfil biofísico fetal (normal quando maior que 6, e anormal quando menor ou igual a 6). As variáveis clinicamente relevantes e estatisticamente significativas foram analisadas pela regressão logística. A série compôs-se de 46 pacientes classificadas nos grupos 1 (24 casos) e 2 (22 casos) e as seguintes variáveis foram estatisticamente relacionadas à ocorrência de acidemia no nascimento (p0,05): idade materna, síndrome hipertensiva, cardiotocografia anormal, presença de desaceleração, e ausência de movimentos respiratórios. Na regressão logística, a presença de desaceleração foi preditora de acidemia (p=0,024; OR=8,2; IC95%=1,2-52). Os presentes achados sustentam que a presença de acidemia ao nascimento em fetos com dopplevelocimetria anormal e fluxo diastólico positivo das AU está associada principalmente à anormalidade nos parâmetros agudos da avaliação da vitalidade fetal. A presença de desaceleração no traçado cardiotocográfico foi preditora de acidemia ao nascimento. / A longitudinal prospective study was conducted on 46 pregnancies with umbilical artery abnormal pulsatility index and positive diastolic flow velocity. Patients were evaluated at the Fetal Surveillance Unit/ Obstetrics Clinics of the University of São Paulo Medical School General Hospital (HCFMUSP) between February 2007 and March 2009. The objective of this study was to identify a potential association between fetal antenatal surveillance tests and acidemia at birth, in pregnancies with umbilical artery abnormal Doppler velocimetry and positive diastolic flow. In the same context, this research aimed to establish the correlation of data of birth, and neonatal outcome with umbilical cord pH below 7,20. The development of reversed or absent end- diastolic flow velovity in the umbilical artery was an excluision criteria. The cases were divided in two groups, according to the presence (Group 1) or absence (Group 2) of acidemia at birth (pH below 7.20), based on umbilical cord blood gas measurement immediately after birth. The following variables were submitted to univariate analysis comparing Groups 1 and 2: maternal age, hypertensive syndrome, corticosteroid use (for lung maturation), gestational age at birth, and fetal vitality assessments on the day of delivery. The Doppler parameters analysed were: pulsatility index of the umbilical artery, middle cerebral artery and the pulsatility index for veins for the ductus venosus. The following variables of the fetal biophysical profile were obtained: cardiotocography or nonstress test ( normal/ abnormal), presence of late deceleration, presence of deceleration (late or severe variable decelerations, or prolonged bradycardia), absence of fetal breathing movements, presence of oligohydramnios and biophysical profile score (considered normal when the score was higher than 6). Clinically relevant and statistically significant variables were analyzed by logistic regression. The series included 46 patients divided in Group 1 (n=24 with acidosis) and Group 2 (n=22 without acidosis), and the following variables were statistically correlated to acidemia at birth (p0.05): maternal age, hypertensive syndrome, abnormal cardiotocographic findings, deceleration (late deceleration, or variable deceleration with poor prognosis, or prolonged deceleration), and absence of respiratory movements. On logistic regression, the presence of deceleration was predictive of acidemia (p=0,024; OR=8,2; CI95%=1,2-52). In conclusion, we believe that the presence of acidemia at birth in fetuses with umbilical artery positive diastolic flow and abnormal Doppler velocimetry is mainly associated with abnormality of acute parameters of fetal well-being. The finding of deceleration on cardiotocographic assessments was predictive of acidemia at birth. ____________________

Page generated in 0.0589 seconds