• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 1
  • Tagged with
  • 9
  • 9
  • 8
  • 8
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Percepção térmica de idosos / Thermal perception of the elderly

Montanheiro, Fabiana Padilha [UNESP] 03 March 2016 (has links)
Submitted by FABIANA PADILHA MONTANHEIRO null (fpmontanheiro@yahoo.com.br) on 2016-04-27T11:37:41Z No. of bitstreams: 1 FABIANA PADILHA MONTANHEIRO_2016.pdf: 1833961 bytes, checksum: d83a3427b3bd4997f83da6c40a0ec6b5 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-04-29T17:53:23Z (GMT) No. of bitstreams: 1 montanheiro_fp_me_bauru.pdf: 1833961 bytes, checksum: d83a3427b3bd4997f83da6c40a0ec6b5 (MD5) / Made available in DSpace on 2016-04-29T17:53:23Z (GMT). No. of bitstreams: 1 montanheiro_fp_me_bauru.pdf: 1833961 bytes, checksum: d83a3427b3bd4997f83da6c40a0ec6b5 (MD5) Previous issue date: 2016-03-03 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / No panorama mundial o número de pessoas com 60 anos ou mais vem aumentando rapidamente. A grande maioria dos idosos que vive de forma independente deseja continuar seu estilo de vida atual, e para isso precisa de apoio extra e orientação para envelhecer com bem-estar e saúde. Essas condições incluem a convivência em ambientes agradáveis, inclusive em relação ao conforto térmico. Neste contexto, este trabalho avaliou a sensação térmica de idosos, comparando-a com os resultados do índice PMV (Voto Médio Estimado: Predicted Mean Vote) de Fanger. Foi realizada uma pesquisa exploratória de abordagem qualitativa (questionários) e quantitativa (medições com termômetros de bulbo seco, bulbo úmido e de globo), conforme a norma ISO 7730:2006; 2011, em três instituições que oferecem serviços de atividades específicas para a faixa populacional na cidade de Bauru (SP): o SESI (Serviço Social da Indústria), o SESC (Serviço Social do Comércio) e a AAPIBR (Associação dos aposentados, pensionistas e idosos de Bauru e Região). Os resultados obtidos demonstraram que as sensações térmicas reais (STR) relatadas pelos idosos (sensações subjetivas) são estatisticamente similares às calculadas pela equação do PMV (sensações analíticas) para três faixas desse índice: -1, 0 e 1. / In the global landscape, the number of people aged 60 and over is increasing rapidly. The vast majority of seniors who live independently wish to continue their current lifestyle, and for that they need extra support and guidance to grow old with wellness and health. These conditions include living in pleasant environments, including thermal comfort. In this context, this study evaluated the thermal sensation of the elderly, comparing it with the results from the PMV (Predicted Mean Vote) method (Fanger). An exploratory research with qualitative (questionnaires) and quantitative approach (measured with dry-bulb, wet-bulb and globe thermometers) was performed according to ISO 7730: 2006; 2011, in three institutions that offer specific activities services for the population group in the city of Bauru (São Paulo state): SESI (Industrial Social Services), SESC (Commercial Social Services) and AAPIBR (Association of retirees, pensioners and seniors of Bauru and region). The results showed that the actual thermal sensations (ATS) reported by the elderly (subjective sensations) are statistically similar to those calculated by the PMV equation (analytical sensations) on a threepoint scale: -1, 0 and 1. / MCA 162174
2

Qualidade do sombreamento natural de três espécies arbóreas visando ao conforto térmico animal /

Gurgel, Estelita Maria, 1958. January 2010 (has links)
Resumo: O sombreamento promovido por árvores constitui um dos melhores dispositivos externos para controle e redução dos efeitos da radiação solar. Natural e de baixo custo, este recurso é de extrema utilidade para o conforto térmico dos seres vivos, especialmente em países de clima quente, onde a incidência de radiação solar é alta. Este trabalho teve como objetivo avaliar a eficiência térmica do sombreamento natural proporcionado por diferentes espécies arbóreas, por meio de medições de varáveis climáticas e de índices de conforto térmico. A pesquisa foi desenvolvida no município de Botucatu, SP e foram avaliadas as sombras de nove indivíduos arbóreos, sendo três exemplares da espécie pau-terra-da-areia (Qualea dichotoma (Warm.) Stafl.), três da espécie chico-pires (Pithecolobium incuriale (Vell.) Benth.) e três da espécie copaíba (Copaifera langsdorffii Desf.). Foram registrados à sombra e a céu aberto os dados de temperatura do ar e umidade relativa, temperatura de ponto de orvalho e temperatura de globo negro e velocidade do vento, durante o verão, ao longo do dia, com leituras horárias entre 8h e 17h. Adotou-se o delineamento estatístico inteiramente casualizado (DIC). Os resultados foram avaliados por meio dos índices de conforto térmico ITU, ITGU, CTR, e por meio da avaliação para o dia crítico do período analisado. Concluiu-se que houve diferença estatística entre as espécies estudadas e de maneira geral a espécie copaíba foi a que apresentou um maior índice de redução da carga térmica de radiação, sendo a pau-terra-da-areia a que apresentou uma menor redução / Abstract: The shading promoted by trees constitutes one of the best external devices to control and to reduce the effects of solar radiation. Natural and economical, such resource is extremely useful to the thermal comfort of living creatures, especially in counties with hot weather, where the incidence of solar radiation is high. This work aimed at evaluating the thermal efficiency of the natural shading given by different species of trees through measurements of climatic variables and indexes of thermal comfort. The research was developed in Botucatu County (São Paulo) and the shade of nine trees were evaluated; three of the species pau-terra-da-areia (Qualea dichotoma (Warm.) Stafl.), three of the species chico-pires (Phithecolobium incuriale (Vell.) Benth.) and three of the species copaiba (Copaifera langsdorffii Desf.). The air temperature and the relative humidity, the dew point temperature, the globe temperature of Vernon, and the wind speed data were taken in the shade during summer, throughout the day with readings between 8 am and 5 pm in the shade and exposed sun. The completely random statistical design was adopted (DIC). The results were evaluated using thermal comfort indexes THI, BGHI, CTR and using evaluation on the critical day for the period analyzed. It was concluded that there was a statistical difference among the species used and, as a whole, the copaiba species was the one which presented the highest index of radiant thermal load reduction and the pau-terra-da-areia, the one which presented the lowest index / Orientador: Odivaldo José Seraphim / Coorientador: Iran José Oliveira da Silva / Banca: Lucila Chebel Labaki / Banca: Ana Maria Liner Pereira Lima / Mestre
3

Qualidade do sombreamento natural de três espécies arbóreas visando ao conforto térmico animal

Gurgel, Estelita Maria [UNESP] 26 August 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-08-26Bitstream added on 2014-06-13T20:52:16Z : No. of bitstreams: 1 gurgel_em_me_botfca.pdf: 1540814 bytes, checksum: 2a27aab761192d5bcaf86f784c206c3c (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O sombreamento promovido por árvores constitui um dos melhores dispositivos externos para controle e redução dos efeitos da radiação solar. Natural e de baixo custo, este recurso é de extrema utilidade para o conforto térmico dos seres vivos, especialmente em países de clima quente, onde a incidência de radiação solar é alta. Este trabalho teve como objetivo avaliar a eficiência térmica do sombreamento natural proporcionado por diferentes espécies arbóreas, por meio de medições de varáveis climáticas e de índices de conforto térmico. A pesquisa foi desenvolvida no município de Botucatu, SP e foram avaliadas as sombras de nove indivíduos arbóreos, sendo três exemplares da espécie pau-terra-da-areia (Qualea dichotoma (Warm.) Stafl.), três da espécie chico-pires (Pithecolobium incuriale (Vell.) Benth.) e três da espécie copaíba (Copaifera langsdorffii Desf.). Foram registrados à sombra e a céu aberto os dados de temperatura do ar e umidade relativa, temperatura de ponto de orvalho e temperatura de globo negro e velocidade do vento, durante o verão, ao longo do dia, com leituras horárias entre 8h e 17h. Adotou-se o delineamento estatístico inteiramente casualizado (DIC). Os resultados foram avaliados por meio dos índices de conforto térmico ITU, ITGU, CTR, e por meio da avaliação para o dia crítico do período analisado. Concluiu-se que houve diferença estatística entre as espécies estudadas e de maneira geral a espécie copaíba foi a que apresentou um maior índice de redução da carga térmica de radiação, sendo a pau-terra-da-areia a que apresentou uma menor redução / The shading promoted by trees constitutes one of the best external devices to control and to reduce the effects of solar radiation. Natural and economical, such resource is extremely useful to the thermal comfort of living creatures, especially in counties with hot weather, where the incidence of solar radiation is high. This work aimed at evaluating the thermal efficiency of the natural shading given by different species of trees through measurements of climatic variables and indexes of thermal comfort. The research was developed in Botucatu County (São Paulo) and the shade of nine trees were evaluated; three of the species pau-terra-da-areia (Qualea dichotoma (Warm.) Stafl.), three of the species chico-pires (Phithecolobium incuriale (Vell.) Benth.) and three of the species copaiba (Copaifera langsdorffii Desf.). The air temperature and the relative humidity, the dew point temperature, the globe temperature of Vernon, and the wind speed data were taken in the shade during summer, throughout the day with readings between 8 am and 5 pm in the shade and exposed sun. The completely random statistical design was adopted (DIC). The results were evaluated using thermal comfort indexes THI, BGHI, CTR and using evaluation on the critical day for the period analyzed. It was concluded that there was a statistical difference among the species used and, as a whole, the copaiba species was the one which presented the highest index of radiant thermal load reduction and the pau-terra-da-areia, the one which presented the lowest index
4

Análise dos parâmetros de conforto térmico em habitações populares de um conjunto em João Pessoa/ PB.

Silva, Nayane Laurentino da 29 May 2015 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2016-04-20T11:59:51Z No. of bitstreams: 1 arquivo total.pdf: 5479543 bytes, checksum: b332b9981e52cb027572641c33c10f16 (MD5) / Made available in DSpace on 2016-04-20T11:59:51Z (GMT). No. of bitstreams: 1 arquivo total.pdf: 5479543 bytes, checksum: b332b9981e52cb027572641c33c10f16 (MD5) Previous issue date: 2015-05-29 / The search for mild conditions for users of buildings not air-conditioned, especially residential is of paramount importance in hot and humid regions. Climatic factors represent major influence on environmental projects built for getting the comfort of its occupants and efficiency in energy consumption. The research is meant to examine the parameters of thermal comfort in affordable housing a set in Singapore and the relationship of each of the comfort indices PMV and PPD, this because the thermal conditions under which the inhabitants are subjected may exercise great influence on their behavior, reactions and health. The research is descriptive, with a quantitative and qualitative approach, using data collected inside the residence, based on the ISO 7730/2005, to analyze the environment by means of statistical techniques and computational resources. The housing Anayde Beiriz, chosen for study, is situated in the neighborhood of Industries in the city of João Pessoa / Paraíba. The assessed apartments have different orientations according to their location on the ground; addition to situate on the last floor and the ends of each block. The sample consisted of 19 apartments of which data were collected from 8h to 17h in the days selected using the equipment called, Heat Stress Meter (TGD 300). With the data a statistical analysis was performed to identify which parameters have most influence on thermal comfort those affordable housing. The results showed the thermal behavior within the evaluated units that resulted in high temperatures analyzed in the winter and summer periods. It was concluded that the personal and climatic variables, involving the parameters of thermal comfort, have correlation with the wind chill into the housing having high correlation to air temperature and low correlation thermal resistance of clothing. All units showed thermal discomfort with the PMV values above 0.5, ranking environments as slightly warm or hot in most of the evaluated times, with the PPD index greater than 10% in both periods studied. - Winter and Summer Yet in the winter for a few hours of the morning period showed sensation of thermal comfort, with the lowest PPD index or equal to 10%, with a tendency that feeling also occur at night. / A busca de condições amenas para os usuários de edifícios não climatizados, sobretudo os residenciais é de suma importância em regiões de clima quente e úmido. Os fatores climáticos representam grande influência nos projetos do ambiente construído para a obtenção do conforto dos seus ocupantes e eficiência no consumo de energia. A pesquisa tem como objetivo principal analisar os parâmetros de conforto térmico em habitações populares de um conjunto em João Pessoa e a relação de cada um nos índices de conforto PMV e PPD, isto porque, as condições térmicas sob as quais os moradores são submetidos podem exercer grande influência sobre seu comportamento, reações e saúde. A pesquisa é de natureza descritiva, com uma abordagem quanti-qualitativa, ao utilizar dados coletados no interior da residência, baseados a Norma ISO 7730/2005, para analisar o ambiente por meio de técnicas estatísticas e recursos computacionais. O conjunto habitacional Anayde Beiriz, escolhido para estudo, está situado no bairro das Industrias na cidade de João Pessoa/Paraíba. Os apartamentos avaliados apresentam diferentes orientações conforme sua locação no terreno; além de situarem-se no ultimo pavimento e nas extremidades de cada bloco. A amostra foi composta por 19 apartamentos dos quais foram coletados dados das 8h ás 17h nos dias escolhidos, utilizando o equipamento denominado, Medidor de Estresse Térmico (TGD 300). Com os dados foi realizada uma análise estatística para identificar quais parâmetros possuem maior influência no conforto térmico naquelas habitações populares. Os resultados apresentaram o comportamento térmico dentro das habitações avaliadas que resultaram em temperaturas elevadas nos períodos analisados do Inverno e Verão. Concluiu-se que as variáveis pessoais e climáticas, que envolvem os parâmetros de conforto térmico, possuem correlação com a sensação térmica dentro das habitações, tendo alta correlação a temperatura do ar e baixa correlação a resistência térmica da vestimenta. Todas as habitações apresentaram desconforto térmico, com os valores do PMV acima de 0,5, classificando os ambientes como levemente quente ou quente na maioria dos horários avaliados, com o índice PPD superior a 10% nos dois períodos estudados - Inverno e Verão. Todavia, no inverno durante algumas horas do período matutino revelaram sensação de conforto térmico, apresentando o índice PPD menor ou igual a 10%, com tendência dessa sensação ocorrer também à noite.
5

Índices de conforto térmico e adaptabilidade de fêmeas bubalinas em pastejo no Agreste de Pernambuco

COSTA, Lígia Alexandrina Barros da 28 February 2007 (has links)
Submitted by (edna.saturno@ufrpe.br) on 2017-04-26T15:36:43Z No. of bitstreams: 1 Ligia Alexandrina Barros da Costa.pdf: 401629 bytes, checksum: 41474d2518470019394d748cf22e8e59 (MD5) / Made available in DSpace on 2017-04-26T15:36:43Z (GMT). No. of bitstreams: 1 Ligia Alexandrina Barros da Costa.pdf: 401629 bytes, checksum: 41474d2518470019394d748cf22e8e59 (MD5) Previous issue date: 2007-02-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The objectives of this work were to determine the best indexes of thermal comfort for buffaloes and to estimate the upper critical levels of these indexes, based on the physiologic parameters. The experiment was carried from february to april at agreste region of the Pernambuco state. Physiologic parameters as rectal temperature (Tr), breathing frequency (Fr) and skin temperature (Tp) were measured thrice to every week in the periods of the morning and afternoon. Sweating rate (Tsud) was measured in the afternoon, once to every week. Correlation and regression analysis were made using data obtained from ten buffaloes: five heifers and five pregnant buffaloes cows. The results showed that Fr was better than rectal temperature (Tr) and sweating rate (Tsud) as an indicator of heat stress for pregnant bufalloes cows. ITGU was better than ITU, based on Fr. Based on Tr the estimated upper critical levels of temperature-humidity index (ITU) and black globe temperature and humidity index (ITGU) were 79,5 and 89,1, respectively, for the heifers and based on breathing frequency those estimated critical levels were, respectively, 77 and 83. Based on Fr the estimated critical values of ITU and ITGU were 79 and 81, respectively, for the pregnant buffaloes cows. / O objetivo deste trabalho foi determinar os melhores índices de conforto térmico para bubalinos estimando seus valores críticos, baseando-se nos parâmetros fisiológicos. O experimento foi conduzido de fevereiro a abril na região agreste de Pernambuco. Os parâmetros fisiológicos temperatura retal (Tr), freqüência respiratória (Fr) e temperatura de pele (Tp) foram avaliados três vezes por semana nos períodos da manhã e da tarde e a taxa de sudação (Tsud) foi mensurada apenas à tarde, uma vez a cada semana. As medidas para análise de correlação entre as variáveis e regressão foram obtidas de dez animais: cinco novilhas e cinco búfalas em gestação. Os resultados obtidos evidenciaram, nas búfalas em gestação, que Fr foi o melhor indicador de estresse térmico que temperatura retal (Tr) e taxa de sudação (Tsud). O ITGU revelou ser o melhor índice que o ITU, baseando-se na Fr. Com base na Tr foram estimados valores críticos de índice de temperatura e umidade (ITU) e índice de temperatura de globo e umidade (ITGU) iguais a 79,5 e 89,1, respectivamente, para as novilhas. Baseando-se na Fr esses valores foram, respectivamente, 77 e 83. Para as búfalas, considerando a Fr, os valores críticos de ITU e ITGU foram 79 e 81, respectivamente.
6

Komfort- och ventilationsanalys på Lersäters värmeverk : PMV-beräkningar och ventilationsmätningar i ett pannhus samt två intilliggande lokaler / Comfort and ventilation analysis on Lersäters värmeverk : PMV calculations and ventilation measurements in a boiler room and two adjacent buildings

Sjöberg, John January 2019 (has links)
Den globala uppvärmningen är en stor utmaning för världen att hantera och därför har länder som Sverige och unioner som EU kommit överens om olika klimatmål. Fram till 2020 är planen att utsläppen av växthusgaser skall sänkas med 20% jämfört med nivåerna 1990 och sen 2050 skall det reduceras med 80%. För att kunna möta dessa miljömål måste energiproduktionen inom EU-länderna bli mer miljövänlig. Ett sätt att producera sådan energi är med biobränslen vilket kan göras genom förbränning av biobränslena i en fjärrvärmeanläggning. Därmed blir det viktigt att alla energiproducenter strävar åt att gå mot en mer miljövänlig energiproduktion. Utöver att energiomvandlingen måste göras på ett miljövänligt sätt för att uppnå ett hållbart samhälle måste bra arbetsklimat också erhållas på anläggningarna. För om ett bra arbetsklimat inte infinner sig kan hälsan hos dem anställda riskeras med hälsoproblem som till exempel illamående och i värsta fall hjärtproblem. Dåligt arbetsklimat kan uppkomma på olika sätt men två exempel är vid för höga inomhustemperaturer eller dålig luftkvalitet. För att utvärdera hur bra ett inomhusklimat är finns olika typer av komfortindex, i denna studie har PMV-metoden använts för att utvärdera komfortnivåerna på Lersäters värmeverk som är en del av Kils Energi AB. Genom att samla in klimatdata inne i tre lokaler som används vid fjärrvärmeproduktionen kunde komfortnivåer för samtliga våningar beräknas. Dessutom har luftflöden i ventilationssystemet beräknats för vardera lokal och don för att säkerställa att anläggningen möter de rekommenderade kraven för ventilation från Arbetsmiljöverket. Ett av sätten att säkerställa ett bra arbetsklimat i lokaler är att ha ett väl fungerande ventilationssystem. Finns många olika tillvägagångssätt för att få en lokal väl ventilerad där vissa är energikrävande och vissa inte. Lersäters värmeverk har ett tilluftsventilationssystem som har pannan som utflöde ur pannhuset. PMV:s som beräknades fram i Lersäters värmeverk varierade kraftigt beroende på vilken lokal och vilken våning som undersöktes. När spjällen var stängda i pannhuset blev det beräknade PMV högre än 3 på våning 5 och 6 i pannhuset vilket är över det maximala värdet för PMV-metoden. Längre ner i pannhuset sjönk PMV till mer acceptabla nivåer där det gick mellan 1–2 för resten av anläggningen. Två olika fallstudier utfördes där olika fläktfrekvenser på ventilationssystemet och med öppna eller stängda spjäll i pannhuset. När spjällen var öppna blev komforten bättre i pannhuset. På våning 5 och 6 i pannhuset ökade komforten avsevärt när spjällen var öppna i jämförelse mot vid stängda spjäll. PMV minskade till runt 2 istället för 3–4 vid stängda spjäll. Pannhuset hade upp till 18 gånger högre luftomsättning än rekommenderade värden för inomhusklimat men stor del av denna luft blev stillastående på de lägsta våningarna där komforten blev god men på bekostnad av låga komfortnivåer på de övre våningarna. På dem två översta våningarna i pannhuset vid grundfallet var PMV till och med högre än det maximala värdet PMV-metoden normalt kan ge. En undersökning av vad de anställda tyckte om klimatet utfördes med hjälp av ett frågeformulär, se bilaga 3. Resultaten från formuläret visade att stora delar av mätresultaten stämde överens med dem anställdas åsikter. Personliga preferenser varierar alltid från person till person men genomsnittet bekräftade många av resultaten utöver komfortnivåerna i lagerlokalen 108an. I lagerlokalen 108an visade mätningarna en god komfort medan dem anställda ansåg den vara väldigt varm. Anledningen till denna skillnad är att lagerlokalen 108an påverkas mer av vilken säsong det är. För i beräkningarna visas bara resultatet från våren när utomhustemperaturen var låg medan de anställda bygger uppfattningen på hela året. Eftersom alla in- och utflöden för ventilationen sitter monterat på samma sida av pannhuset blir luftomrörningen dålig trots det aktiva ventilationssystemet som är monterat på anläggningen. Vilket rökanalyserna bevisar då bara ett par meter ifrån utflöden som spjäll eller insugen till pannan avtar lufttransporten mot dessa. Placering av utflödena i pannhuset är dessutom monterade på samma sida och dessutom sitter spjäll 1 och primär- och sekundärinsuget till pannan precis ovanför varandra. Detta leder till att trots höga flöden av friskluft tillgodoses in i lokalen blir utbytet av den förorenade luften bristfällig. För att förbättra komforten i pannhuset måste luftomrörningen förbättras. Det kan göras på flera olika sätt men till exempel genom att installera fler spjäll på väggarna och installera ställbara takluckor för att bättre kunna ventilera ut den varma stillastående luften runt taket. / The global warming is a big challenge for the world to handle and therefore have countries such as Sweden and unions agreed on different climate goals. Before 2020 the goal is to reduce the emissions of greenhouse gases by 20% compared to the levels at 1990 and then before 2050 reduce it to 80%. To achieve these climate goals the energy production within the EU gas to become more environmentally friendly. One way of producing such energy is with biofuels which can be done by burning biofuels in a district heating. Therefore, it’s important that energy producers try to become more environmentally friendly. To reach a more sustainable society the energy production must become environmentally friendly and make sure that the workers have good working conditions. Because if bad working conditions are not achieved the workers could get health problems, such as nausea and in worst case heart problems. Bad working conditions can be for example to high temperature indoors or poor air quality. To evaluate how good an indoor climate is there are different types of comfort index, in this study the PMV-method has been used to evaluate the comfort levels at Lersäters värmeverk which is a part of Kils Energi AB. Through climate data collection from inside of three different buildings that are used at the production facility could the comfort levels for all stories be calculated. Also, the flow of fresh air in the different rooms and from each diffuser was measured to secure that enough air was supplied to the buildings. One was of securing that good working conditions is achieved is to have a well-functioning ventilations system. There are many ways of making a building will well ventilated, there are some that require energy and some that don’t. Lersäters värmeverk have an active ventilation system which transport fresh air into the buildings through ducts. The calculated PMVs for Lersäters värmeverk varied heavily depending on which building and story that was evaluated. The calculated PMVs on Lersäters värmeverk varied largely depending on which building and what floor was evaluated. When the dampers were closed the PMV on floor 5 and 6 in the boiler room was higher than 3 which is normally the maximum value for the PMV-method. Further down in the boiler room the PMV decreased to more acceptable levels and was between 1 and 2 for the rest of the facility. Two different case studies were done where different frequencies on the ventilation system was used and if the dampers were open or closed in the boiler room. When the dampers were open the comfort was improved in the boiler room. On story 5 and 6 in the boiler room the comfort was greatly improved when the dampers were opened compared to when they were closed. The PMV went from above maximum to around 2. For the case studies different frequencies for the ventilation fan was tested and how open or shut dampers impacted the comfort levels.   When the dampers were open like in case 2 the comfort in the boiler room was improved. For story 5 and 6 in the boiler room the comfort was greatly improved with open dampers which was lowered to around 2 instead of 3-4 in the standard-case. The boiler room up to 18 times higher air intake than the minimum requirement for indoors climate but large part of this are became stagnant at the lower stories which made the comfort good there but at the cost of the comfort of the higher stories. With the comfort levels above maximum for the PMV-method at story 5 and 6 in the boiler room. A survey of what the employees at Lersäters värmeverk thought about the climate at the facility was done with a questionnaire. The results from the survey confirmed a lot of the calculated values for the comfort. But personal preferences always differ from person to person, but the averages confirmed the results except for the warehouse building called warehouse 108. In warehouse 108 the calculated values showed good comfort, but the employees thought it was a lot warmer. The reason for this difference is probably that this building is on a higher degree effected by seasonal changes and the employees evaluate the total comfort level for the building while the calculations only show results during the spring while the outdoor temperature is still low. All intake and outtake of air is located at the same side in the boiler room which makes the air circulation bad even though an active ventilation system is installed. Which the smoke analysis confirmed by noticing that the transport of air towards the outtakes reduces to almost zero just a few meters away from an air outtake. The placements of the outflows are also placed on the same side in the boiler room and damper 1 is placed right above the primary and secondary intake to the boiler. This led to that even though lots of air is supplied into the building the exchange between the contaminated air and the fresh air was far from good. To improve this exchange the air circulation must improve. This can be done in several ways, one way of doing it is the install more dampers and controllable hatches in the ceiling to be able to ventilate out the hot air around the ceiling.
7

Níveis de proteína bruta e balanço eletrolítico para frangos de corte / Levels from protein and electrolyte balance for broiler

Navarini, Franciele Clenice 29 May 2009 (has links)
Made available in DSpace on 2017-07-10T17:48:17Z (GMT). No. of bitstreams: 1 Franciele_Navarini.pdf: 271642 bytes, checksum: 28a7bcd130b21facc8ae729e942c43b9 (MD5) Previous issue date: 2009-05-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Four experiments were conducted to evaluate the effects of different electrolyte balance and crude protein in feed for broiler chickens Cobb male line reared in natural conditions of heat stress. In experiment 1, were used 880 chicks in the period from 1 to 7 days of age with an average weight of 52,00 grams. Being housed 22 chicks per experimental unit, comprising a density of 14.10 chicks.m-2 housed in 40 boxes were distributed in a completely randomized design with 8 treatments, five replications. In experiment 2, were used 800 chicks in the period from 8 to 21 days of age with an average weight of 160,00 grams. Being housed 20 chicks per experimental unit, comprising a density of 12.82 chicks.m-2. In experiment 3, were used 640 chicks in the period from 22 to 35 days of age with an average weight of 640 grams. Being housed 16 chicks per experimental unit, comprising a density of 10.25 chicks.m-2. In experiment 4, were used 480 chicks, with an average weight of 1,700 grams, the period from 36 to 42 days of age. Being housed 12 chicks per experimental unit, comprising a density of 7.69 chicks.m-2. The diets were formulated from corn, soybean meal and maize gluten to meet the nutritional requirements of chicks in all experiments, according to Rostagno et al. (2005), except for crude protein whose levels were calculated, considering the levels recommended reducing 5%, 10% and 15%, and two electrolyte balance (200 and 240 mEq.kg-1) in all experiments. The animals received water and food ad libitum. In all the experiments was evaluated zootechnical performance (average gain of weight, average consumption of feed, feed conversion and final weight), and developing bone (index Sedoor). The environmental conditions of the building were monitored six times a day to help the hygrometer, a black globe thermometer and the readings used to calculate the of Black Globe Temperature and Humidity Index (BGHI). During the experimental period, the values of temperature, relative humidity, temperature and black globe BGHI remained above the zone of thermo neutrality of broilers. For the variables of performance in all experiments, except for experiment 4, the chicks had greater weight gain and final weight with the balance of 240 mEq.kg-1. In all experiments, the chicks that received diets with reduced levels of CP showed lower performance on fed diets without reducing protein, independent of the BE. This result is most evident in the diet with a reduction of 15% CP. With regard to blood tests, as reduced levels of CP in the diet, also decreased the concentration of uric acid in serum (p <0.05). For the electrolyte balance of 200 mEq.kg-1 saw the highest amount of calcium in blood serum. The chicks had lower percentage of total protein in blood stock in the range of 240 mEq.kg-1, the average levels of total protein in blood that range from 2.36 (experiment 4) to 2.92 mg.dL-1 (experiment 2) and below 3.6 mg.dL-1, are considered normal. The concentrations of K +, Cl-(Experiment 4) were not influenced (p> 0.05) by treatments. In relation to the concentration of sodium at 21 days of age (Experiment 2), the reduction of diet crude protein decreased (p <0.05) the concentrations of this mineral in serum. This response, however, was not observed at 42 days of age (Experiment 4). For evaluation of bone development, only the levels of CP protein used in the experiment 3, linearly affect the rate of Seedor femur (P <0.05). The effect of GA on the levels of Seedor index was not significant (P <0.05) for all experiments. For chickens from 22 to 35 days of age, levels of CP in the diet caused a linear effect and decreasing the rate of Seedor femur. Only in experiment 1 the levels of protein PB used linearly influence the rate of Seedor tibia (P <0.05), with linear response decreasing. The reduction in the levels of CP in the diet, results in lower values for the index of Seedor by reducing the length and weight of the femur. In general the reduction of 0%, 5%, 10% and 15% crude protein of diet on the recommended per phase, associated with correction of electrolyte balance, was not beneficial in the environmental conditions studied / Foram conduzidos quatro experimentos com o objetivo de avaliar os efeitos de diferentes balanços eletrolíticos e de teores de proteína bruta da ração para frangos de corte machos da linhagem Cobb criados em condições naturais de estresse calórico. No experimento 1 foram utilizadas 880 aves, no período de 1 a 7 dias de idade, com peso médio de 52 gramas. Sendo alojadas 22 aves por unidade experimental, comportando uma densidade de 14,10 aves.m-2 alojados em 40 boxes, distribuídos em delineamento inteiramente casualizados com 8 tratamentos, cinco repetições. No experimento 2, foram utilizadas 800 aves, no período de 8 a 21 dias de idade, com peso médio de 160 gramas. Sendo alojadas 20 aves por unidade experimental, comportando uma densidade de 12,82 aves.m-2. No experimento 3, foram utilizadas 640 aves, no período de 22 a 35 dias de idade com peso médio de 640 gramas. Sendo alojadas 16 aves por unidade experimental, comportando uma densidade de 10,25 aves.m-2. No experimento 4, foram utilizadas 480 aves, com peso médio de 1700 gramas, no período de 36 a 42 dias de idade. Sendo alojadas 12 aves por unidade experimental, comportando uma densidade de 7,69 aves.m-2. As rações foram formuladas a base de milho, farelo de soja e glútem de milho para atender as exigências nutricionais das aves, em todos os experimentos, segundo Rostagno et al. (2005), exceto para proteína bruta cujos níveis foram calculados, considerando os níveis recomendados reduzindo 5%, 10% e 15%, e dois balanços eletrolítico (200 e 240 mEq.kg-1) em todos os experimentos. Os animais receberam água e ração à vontade. Em todos os experimentos foi avaliado desempenho zootécnico (Ganho Médio de Peso, Consumo Médio de Ração, Peso Final e Conversão Alimentar), parâmetros sanguíneos (ácido úrico, proteína total, cálcio, sódio, potássio, cloro); e desenvolvimento ósseo (índice de Sedoor). As condições ambientais do galpão foram monitoradas seis vezes ao dia com auxilio de um termo higrômetro e um termômetro de globo negro e as leituras usadas para calculo do Índice de Temperatura de Globo Negro e Umidade (ITGU). Durante o período experimental, os valores de temperatura, umidade relativa, temperatura de globo negro e ITGU mantiveram-se acima da zona de termoneutralidade para frango de corte. Para as variáveis de desempenho, em todos os experimentos, exceto para o experimento 4, as aves obtiveram maior ganho de peso e peso final com o balanço de 240 mEq.kg-1. Em todos experimentos, as aves que receberam ração com redução dos níveis de PB apresentaram desempenho inferior em relação às alimentadas com ração sem redução protéica, independente do BE. Este resultado fica mais evidente na ração com redução de 15% de PB. Com relação às análises sanguínea, conforme se diminuía os níveis de PB na dieta, diminuía também a concentração de ácido úrico no soro (p<0,05). Para o balanço eletrolítico de 200 mEq.kg-1 verificou-se o maior valor de cálcio no soro sanguíneo. As aves obtiveram menores percentuais sangüíneos de proteína total com balanço na faixa de 240 mEq.kg-1, Os valores médios dos níveis de proteína total no sangue que variam de 2,36 (experimento 4) a 2,92 mg.dL-1 (experimento 2) e encontram-se abaixo de 3,6 mg.dL-1, considerados normais. As concentrações de K+, Cl- (Experimento 4), não foram influenciadas (p>0,05) pelos tratamentos. Em relação à concentração de sódio aos 21 dias de idade (Experimento 2), a redução da proteína bruta da ração diminuiu (p<0,05) as concentrações deste mineral no soro. Esta resposta, entretanto, não foi observada aos 42 dias de idade (Experimento 4). Para avaliação de desenvolvimento ósseo, somente os níveis de proteína PB utilizados no experimento 3, influenciaram linearmente o índice de Seedor do fêmur (P<0,05). O efeito dos níveis de PB sobre o índice de Seedor não foi significativo (P<0,05) para os demais experimentos. Para frangos de 22 a 35 dias de idade, os níveis de PB na ração provocaram efeito linear e decrescente no índice de Seedor do fêmur. Somente no experimento 1 os níveis de proteína PB utilizados influenciaram linearmente o índice de Seedor da tíbia (P<0,05), com resposta linear decrescente. A redução nos níveis de PB na dieta, implica em menores valores para o índice de Seedor, por diminuir o comprimento e peso do fêmur. De maneira geral a redução de 0%, 5%, 10% e 15% da proteína bruta da ração, em relação ao recomendado por fase, associada à correção do balanço eletrolítico, não se mostrou benéfica nas condições ambientais estudadas
8

Interação animal-ambiente: efeito do ambiente climático sobre as respostas fisiológicas e produtivas de vacas Holandesas em free-stall / Animal-environment interaction: effects of climatic environment over physiologic and productive responses of Holstein cows in free-stall

Martello, Luciane Silva 09 June 2006 (has links)
As relações entre os fatores climáticos e as respostas fisiológicas de vacas lactantes são bastante conhecidas, porém sob condições de ambiente controlado. Este estudo teve como objetivo monitorar as respostas dos animais em instalações típicas para vacas leiteiras, para identificar o real impacto do ambiente climático sobre o animal. Foi proposto um método para avaliar o nível de estresse de vacas, que poderá servir como uma ferramenta simples, que traduza as sensações de conforto térmico dos animais. O experimento foi realizado em três fases, a saber: primavera (28 dias), verão (31 dias) e inverno (31 dias). Foram utilizados animais da raça Holandesa com produção média entre 20 a 25 kg leite/dia. Os animais foram alojados em instalação tipo free-stall com acesso livre a um piquete adjacente. Foram avaliadas a freqüência respiratória (FR), a temperatura retal (TR), a temperatura do pelame (TPE), a temperatura auricular (TAU), a temperatura da base da cauda (TCAU), a temperatura da vulva (TVU) e a produção de leite (PL). O ambiente foi monitorado 24 horas por dia, todos os dias, com registros da temperatura de bulbo seco (TBS), da umidade relativa (UR), da temperatura de ponto de orvalho e da temperatura de globo negro (TG). Posteriormente foram calculados os índices de temperatura e umidade (ITU) e o de temperatura de globo e umidade (ITGU). Todas as variáveis fisiológicas apresentaram padrão sazonal bem claro, com maiores valores durante as estações mais quentes (primavera e verão) e menores valores no inverno. A TAU, a TVU e a TCAU apresentaram correlações positivas com a TR, a FR e a TPE, o que indica uma associação entre estas variáveis. Porém estudos adicionais devem ser conduzidos para validar a aplicabilidade destas variáveis (TAU, TVU e TCAU) na caracterização do estresse térmico dos animais. A TPE e a FR foram as variáveis mais influenciadas pelo ambiente climático em todas as estações do ano. O ambiente noturno foi associado às variações da TR, da FR e da TPE, enquanto o ambiente do dia anterior não explicou a variação das respostas fisiológicas. Não houve evidência de efeitos de uma variável ambiental isolada sobre as variáveis fisiológicas, o que indicou a complexidade das relações entre o animal e o ambiente climático. Mesmo com ITU acima de 79, considerado estressante pela literatura estrangeira para vacas lactantes, não foram evidenciados valores estressantes para TR e FR e reduções na produção de leite. O modelo proposto neste trabalho para estimar presença ou ausência de estresse em vacas alojadas em free-stall, apresentou boa aderência ao conjunto de dados, com R&sup2; de 0,43. Dessa forma, disponibiliza uma ferramenta simples e rápida para produtores e técnicos, pela associação de duas medidas fisiológicas (FR e TPE) de fácil mensuração, ou então pela associação de duas variáveis ambientais (TBS e UR). Tal ferramenta diz respeito a uma amostra da população de vacas Holandesas alojadas em determinada instalação e região, o que condiciona o modelo proposto a outros estudos para sua validação em outros rebanhos e regiões. / It has been well known the relation between the environment and physiological answers of lactating dairy cows under controlled environmental conditions. The present study aimed to monitor the animal answers allocated at typical housing system to identify the real environmental impact over it. A method was proposed to evaluate the stress level of the animal, to be used as a tool to identify the sensations of thermal comfort. The experiment was conducted in three phases, in spring (28 days), summer (31 days) and winter (31 days) periods. Holstein dairy cows were used averaging milk yield around 20 to 25 kg/day. The animals were housed in a free stall shed with an open area. Respiratory rate (FR), rectal temperature (TR), surface skin temperature (TPE), internal ear temperature (TAU), tail temperature (TCAU), vulva temperature (TVU) and milk yield (PL) were evaluated. The environmental conditions were monitored during 24 hours every day, by recording the dry bulb temperature (TBS), relative humidity (UR), dew point temperature (Tpo) and black globe temperature (Tg). The calculation of temperature humidity index (ITU) and the black globe humidity index (ITGU) was based on these environmental variables. The physiological variables had a seasonal standard with higher values during hot periods (spring and summer) and lower values during the winter. The IET, VT and TT demonstrated positive correlations with RT, RR and SKT showing association between them. More studies are necessary to validate the applicability of these variables (IET, VT and TT) and to characterize heat stress in dairy cows. SKT and RR were the most influenced by the environment in all seasons. The night environment was associated to the RT, RR and SKT, while the day before environment did not explained the physiological variations. There was no evidence of isolated environmental variables over the physiological ones, showing the complexity between the animal and the environment. Even with the THI values above 79, what is considered stressful to dairy cows, there was no evidence of stressful values for RT and RR and of MY losses. The model proposed in this study to estimate presence or absence of heat stress in dairy cows avails a simple and fast tool to milk producers and technicians, where it could be associated two physiological variables (RR and SKT) of easy measurement or other two environment variables (DBT and RH). However, this result is related to the studied population at a specific housing system and situated at a specific region. Addiitonal studies must be conducted to validate the proposed model to others dairy herds and locations.
9

Interação animal-ambiente: efeito do ambiente climático sobre as respostas fisiológicas e produtivas de vacas Holandesas em free-stall / Animal-environment interaction: effects of climatic environment over physiologic and productive responses of Holstein cows in free-stall

Luciane Silva Martello 09 June 2006 (has links)
As relações entre os fatores climáticos e as respostas fisiológicas de vacas lactantes são bastante conhecidas, porém sob condições de ambiente controlado. Este estudo teve como objetivo monitorar as respostas dos animais em instalações típicas para vacas leiteiras, para identificar o real impacto do ambiente climático sobre o animal. Foi proposto um método para avaliar o nível de estresse de vacas, que poderá servir como uma ferramenta simples, que traduza as sensações de conforto térmico dos animais. O experimento foi realizado em três fases, a saber: primavera (28 dias), verão (31 dias) e inverno (31 dias). Foram utilizados animais da raça Holandesa com produção média entre 20 a 25 kg leite/dia. Os animais foram alojados em instalação tipo free-stall com acesso livre a um piquete adjacente. Foram avaliadas a freqüência respiratória (FR), a temperatura retal (TR), a temperatura do pelame (TPE), a temperatura auricular (TAU), a temperatura da base da cauda (TCAU), a temperatura da vulva (TVU) e a produção de leite (PL). O ambiente foi monitorado 24 horas por dia, todos os dias, com registros da temperatura de bulbo seco (TBS), da umidade relativa (UR), da temperatura de ponto de orvalho e da temperatura de globo negro (TG). Posteriormente foram calculados os índices de temperatura e umidade (ITU) e o de temperatura de globo e umidade (ITGU). Todas as variáveis fisiológicas apresentaram padrão sazonal bem claro, com maiores valores durante as estações mais quentes (primavera e verão) e menores valores no inverno. A TAU, a TVU e a TCAU apresentaram correlações positivas com a TR, a FR e a TPE, o que indica uma associação entre estas variáveis. Porém estudos adicionais devem ser conduzidos para validar a aplicabilidade destas variáveis (TAU, TVU e TCAU) na caracterização do estresse térmico dos animais. A TPE e a FR foram as variáveis mais influenciadas pelo ambiente climático em todas as estações do ano. O ambiente noturno foi associado às variações da TR, da FR e da TPE, enquanto o ambiente do dia anterior não explicou a variação das respostas fisiológicas. Não houve evidência de efeitos de uma variável ambiental isolada sobre as variáveis fisiológicas, o que indicou a complexidade das relações entre o animal e o ambiente climático. Mesmo com ITU acima de 79, considerado estressante pela literatura estrangeira para vacas lactantes, não foram evidenciados valores estressantes para TR e FR e reduções na produção de leite. O modelo proposto neste trabalho para estimar presença ou ausência de estresse em vacas alojadas em free-stall, apresentou boa aderência ao conjunto de dados, com R&sup2; de 0,43. Dessa forma, disponibiliza uma ferramenta simples e rápida para produtores e técnicos, pela associação de duas medidas fisiológicas (FR e TPE) de fácil mensuração, ou então pela associação de duas variáveis ambientais (TBS e UR). Tal ferramenta diz respeito a uma amostra da população de vacas Holandesas alojadas em determinada instalação e região, o que condiciona o modelo proposto a outros estudos para sua validação em outros rebanhos e regiões. / It has been well known the relation between the environment and physiological answers of lactating dairy cows under controlled environmental conditions. The present study aimed to monitor the animal answers allocated at typical housing system to identify the real environmental impact over it. A method was proposed to evaluate the stress level of the animal, to be used as a tool to identify the sensations of thermal comfort. The experiment was conducted in three phases, in spring (28 days), summer (31 days) and winter (31 days) periods. Holstein dairy cows were used averaging milk yield around 20 to 25 kg/day. The animals were housed in a free stall shed with an open area. Respiratory rate (FR), rectal temperature (TR), surface skin temperature (TPE), internal ear temperature (TAU), tail temperature (TCAU), vulva temperature (TVU) and milk yield (PL) were evaluated. The environmental conditions were monitored during 24 hours every day, by recording the dry bulb temperature (TBS), relative humidity (UR), dew point temperature (Tpo) and black globe temperature (Tg). The calculation of temperature humidity index (ITU) and the black globe humidity index (ITGU) was based on these environmental variables. The physiological variables had a seasonal standard with higher values during hot periods (spring and summer) and lower values during the winter. The IET, VT and TT demonstrated positive correlations with RT, RR and SKT showing association between them. More studies are necessary to validate the applicability of these variables (IET, VT and TT) and to characterize heat stress in dairy cows. SKT and RR were the most influenced by the environment in all seasons. The night environment was associated to the RT, RR and SKT, while the day before environment did not explained the physiological variations. There was no evidence of isolated environmental variables over the physiological ones, showing the complexity between the animal and the environment. Even with the THI values above 79, what is considered stressful to dairy cows, there was no evidence of stressful values for RT and RR and of MY losses. The model proposed in this study to estimate presence or absence of heat stress in dairy cows avails a simple and fast tool to milk producers and technicians, where it could be associated two physiological variables (RR and SKT) of easy measurement or other two environment variables (DBT and RH). However, this result is related to the studied population at a specific housing system and situated at a specific region. Addiitonal studies must be conducted to validate the proposed model to others dairy herds and locations.

Page generated in 0.06 seconds