• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 7
  • 3
  • Tagged with
  • 25
  • 25
  • 15
  • 14
  • 9
  • 9
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Design Considerations for Composite Beams Using Precast Concrete Slabs.

Hicks, S., Lawson, R.M., Lam, Dennis January 2006 (has links)
no / Precast concrete floors are widely used in building construction, but there is little detailed design guidance on their application in steel-framed buildings. Traditionally the steel beams have been designed to support the precast slabs on their top flange. However, there are an increasing number of composite frames and slim floor constructions where the precast slabs are designed to interact structurally with the steel frame. Composite action can be developed by welded shear connectors attached to the steel beams and by transverse reinforcement; however, this form of construction is currently outside the provisions of the current codes of practice. This paper discusses some of the particular issues that affect this form of construction, and presents design guidance using the Eurocode methodology.
12

Seismic performance assessment of reinforced concrete buildings with precast concrete floor systems : a thesis submitted in partial fulfilment of the requirements for the degree of Doctor of Philosophy at the University of Cantrebury [i.e. Canterbury] /

Peng, Brian. January 1900 (has links)
Thesis (Ph. D.)--University of Canterbury, 2009. / Typescript (photocopy). "July 2009." Includes bibliographical references. Also available via the World Wide Web.
13

Contribuição ao estudo do desgaste superficial por abrasão em concretos empregados em pisos / Contribution to the study of surface wear by abrasion in concrete used in floors

Silva, Cristina Vitorino da January 2011 (has links)
O desgaste superficial constitui uma das manifestações patológicas mais recorrentes em pisos de concreto. A presença de tal manifestação patológica, proveniente do processo abrasivo, é muito preocupante, uma vez que implica em altos custos para reparar ou substituir este concreto danificado. Portanto, a realização de estudos que buscam avaliar a influência do proporcionamento e tipo de alguns materiais que constituem o traço de concreto, comumente empregado em pisos, é considerada extremamente relevante, no intuito de reduzir a tendência de desgaste dos compósitos. Neste particular, foram avaliados alguns fatores, como o consumo de água (175 l/m³; 190 l/m³; 205 l/m³), o teor de substituição de sílica ativa (0%; 5%; 10%), o teor de adição de microfibras de polipropileno (0 g/m³; 600 g/m³) e o tipo de cimento (CP IV; CP V-ARI). Os ensaios adotados para esta avaliação foram o de resistência à compressão uniaxial, resistência à tração na flexão, dureza superficial por esclerometria, exsudação e resistência à abrasão. Os resultados encontrados mostraram uma influência estatística significativa do tipo de cimento em todas as propriedades avaliadas, sendo que o cimento CP V-ARI apresentou melhor desempenho em comparação ao cimento CP IV, considerando uma mesma relação a/agl (0,53). O fator consumo de água, mantendo-se constante a relação a/agl, mostrou influência significativa na resistência à tração na flexão e na resistência à abrasão dos concretos, e, além disso, foi possível verificar um comportamento semelhante para ambas as propriedades com relação a este parâmetro de controle. Quanto ao teor de substituição de sílica ativa, observa-se que este fator promoveu efeito significativo nas propriedades mecânicas, o que era esperado, na dureza superficial e na exsudação; entretanto, não se verificou influência no desgaste por abrasão dos compósitos cimentícios. Já a adição das microfibras de polipropileno diminuiu significativamente a dureza superficial por esclerometria, sem alterar as demais propriedades analisadas. Os resultados verificados para o desgaste mostraram uma importante relação com as propriedades mecânicas dos concretos. O processo de acabamento como forma de tratamento superficial parece ser efetivo no controle do desgaste por abrasão, uma vez que pode ter minimizado o efeito da exsudação na superfície dos compósitos cimentícios. O consumo de água de 190 l/m³ mostrou ser o teor mais adequado para os materiais e concretos empregados nesta pesquisa. / Surface wear is one of the most frequent pathologies in concrete floors. The presence of such pathological manifestation from the abrasive process is very disturbing, since it implies high costs to repair or replace the damaged concrete. Therefore, studies that seek to evaluate the influence of the proportioning and type of some materials that constitute the mixture proportions of concrete, commonly used on floors, are considered extremely relevant, in order to reduce the tendency of surface wear of composites. In this study, factors such as water consumption (175 l/m³, 190 l/m³, 205 l/m³), replacement content of silica fume (0 %, 5 %, 10 %), addition content of polypropylene fibers (0 g/m³, 600 g/m³) and cement type (CP IV; CP V-ARI) were evaluated. The tests used for this assessment were compressive strength, flexural tensile strength, surface hardness by rebound hammer, bleeding and abrasion resistance. The results showed a significant statistic influence of the cement type on all the properties evaluated, with the cement CP V-ARI presenting a better performance compared to cement CP IV, considering the same w/b ratio (0.53). The water consumption factor, maintaining a constant w/b ratio, showed significant influence on the flexural tensile strength and abrasion resistance of concrete, and, in addition, we could observe a similar behavior for both properties with respect to this parameter of control. Regarding the replacement content of silica fume, it is observed that this factor promoted significant effect on the mechanical properties, which was expected, on the surface hardness and bleeding; however, there was no influence on the abrasion of the cementitious composites. The addition of polypropylene microfibers significantly decrease the surface hardness by rebound hammer, without altering any other property evaluated. The results verified for the wear showed an important relationship with the mechanical properties of concrete. The finishing process as a form of surface treatment seems to be effective in controlling the abrasive wear, since it may have minimized the effect of bleeding on the surface of cementitious composites. The water consumption of 190 l/m³ showed to be the most appropriate content for the materials and concrete used in this research.
14

Contribuição ao estudo do desgaste superficial por abrasão em concretos empregados em pisos / Contribution to the study of surface wear by abrasion in concrete used in floors

Silva, Cristina Vitorino da January 2011 (has links)
O desgaste superficial constitui uma das manifestações patológicas mais recorrentes em pisos de concreto. A presença de tal manifestação patológica, proveniente do processo abrasivo, é muito preocupante, uma vez que implica em altos custos para reparar ou substituir este concreto danificado. Portanto, a realização de estudos que buscam avaliar a influência do proporcionamento e tipo de alguns materiais que constituem o traço de concreto, comumente empregado em pisos, é considerada extremamente relevante, no intuito de reduzir a tendência de desgaste dos compósitos. Neste particular, foram avaliados alguns fatores, como o consumo de água (175 l/m³; 190 l/m³; 205 l/m³), o teor de substituição de sílica ativa (0%; 5%; 10%), o teor de adição de microfibras de polipropileno (0 g/m³; 600 g/m³) e o tipo de cimento (CP IV; CP V-ARI). Os ensaios adotados para esta avaliação foram o de resistência à compressão uniaxial, resistência à tração na flexão, dureza superficial por esclerometria, exsudação e resistência à abrasão. Os resultados encontrados mostraram uma influência estatística significativa do tipo de cimento em todas as propriedades avaliadas, sendo que o cimento CP V-ARI apresentou melhor desempenho em comparação ao cimento CP IV, considerando uma mesma relação a/agl (0,53). O fator consumo de água, mantendo-se constante a relação a/agl, mostrou influência significativa na resistência à tração na flexão e na resistência à abrasão dos concretos, e, além disso, foi possível verificar um comportamento semelhante para ambas as propriedades com relação a este parâmetro de controle. Quanto ao teor de substituição de sílica ativa, observa-se que este fator promoveu efeito significativo nas propriedades mecânicas, o que era esperado, na dureza superficial e na exsudação; entretanto, não se verificou influência no desgaste por abrasão dos compósitos cimentícios. Já a adição das microfibras de polipropileno diminuiu significativamente a dureza superficial por esclerometria, sem alterar as demais propriedades analisadas. Os resultados verificados para o desgaste mostraram uma importante relação com as propriedades mecânicas dos concretos. O processo de acabamento como forma de tratamento superficial parece ser efetivo no controle do desgaste por abrasão, uma vez que pode ter minimizado o efeito da exsudação na superfície dos compósitos cimentícios. O consumo de água de 190 l/m³ mostrou ser o teor mais adequado para os materiais e concretos empregados nesta pesquisa. / Surface wear is one of the most frequent pathologies in concrete floors. The presence of such pathological manifestation from the abrasive process is very disturbing, since it implies high costs to repair or replace the damaged concrete. Therefore, studies that seek to evaluate the influence of the proportioning and type of some materials that constitute the mixture proportions of concrete, commonly used on floors, are considered extremely relevant, in order to reduce the tendency of surface wear of composites. In this study, factors such as water consumption (175 l/m³, 190 l/m³, 205 l/m³), replacement content of silica fume (0 %, 5 %, 10 %), addition content of polypropylene fibers (0 g/m³, 600 g/m³) and cement type (CP IV; CP V-ARI) were evaluated. The tests used for this assessment were compressive strength, flexural tensile strength, surface hardness by rebound hammer, bleeding and abrasion resistance. The results showed a significant statistic influence of the cement type on all the properties evaluated, with the cement CP V-ARI presenting a better performance compared to cement CP IV, considering the same w/b ratio (0.53). The water consumption factor, maintaining a constant w/b ratio, showed significant influence on the flexural tensile strength and abrasion resistance of concrete, and, in addition, we could observe a similar behavior for both properties with respect to this parameter of control. Regarding the replacement content of silica fume, it is observed that this factor promoted significant effect on the mechanical properties, which was expected, on the surface hardness and bleeding; however, there was no influence on the abrasion of the cementitious composites. The addition of polypropylene microfibers significantly decrease the surface hardness by rebound hammer, without altering any other property evaluated. The results verified for the wear showed an important relationship with the mechanical properties of concrete. The finishing process as a form of surface treatment seems to be effective in controlling the abrasive wear, since it may have minimized the effect of bleeding on the surface of cementitious composites. The water consumption of 190 l/m³ showed to be the most appropriate content for the materials and concrete used in this research.
15

Contribuição ao estudo do desgaste superficial por abrasão em concretos empregados em pisos / Contribution to the study of surface wear by abrasion in concrete used in floors

Silva, Cristina Vitorino da January 2011 (has links)
O desgaste superficial constitui uma das manifestações patológicas mais recorrentes em pisos de concreto. A presença de tal manifestação patológica, proveniente do processo abrasivo, é muito preocupante, uma vez que implica em altos custos para reparar ou substituir este concreto danificado. Portanto, a realização de estudos que buscam avaliar a influência do proporcionamento e tipo de alguns materiais que constituem o traço de concreto, comumente empregado em pisos, é considerada extremamente relevante, no intuito de reduzir a tendência de desgaste dos compósitos. Neste particular, foram avaliados alguns fatores, como o consumo de água (175 l/m³; 190 l/m³; 205 l/m³), o teor de substituição de sílica ativa (0%; 5%; 10%), o teor de adição de microfibras de polipropileno (0 g/m³; 600 g/m³) e o tipo de cimento (CP IV; CP V-ARI). Os ensaios adotados para esta avaliação foram o de resistência à compressão uniaxial, resistência à tração na flexão, dureza superficial por esclerometria, exsudação e resistência à abrasão. Os resultados encontrados mostraram uma influência estatística significativa do tipo de cimento em todas as propriedades avaliadas, sendo que o cimento CP V-ARI apresentou melhor desempenho em comparação ao cimento CP IV, considerando uma mesma relação a/agl (0,53). O fator consumo de água, mantendo-se constante a relação a/agl, mostrou influência significativa na resistência à tração na flexão e na resistência à abrasão dos concretos, e, além disso, foi possível verificar um comportamento semelhante para ambas as propriedades com relação a este parâmetro de controle. Quanto ao teor de substituição de sílica ativa, observa-se que este fator promoveu efeito significativo nas propriedades mecânicas, o que era esperado, na dureza superficial e na exsudação; entretanto, não se verificou influência no desgaste por abrasão dos compósitos cimentícios. Já a adição das microfibras de polipropileno diminuiu significativamente a dureza superficial por esclerometria, sem alterar as demais propriedades analisadas. Os resultados verificados para o desgaste mostraram uma importante relação com as propriedades mecânicas dos concretos. O processo de acabamento como forma de tratamento superficial parece ser efetivo no controle do desgaste por abrasão, uma vez que pode ter minimizado o efeito da exsudação na superfície dos compósitos cimentícios. O consumo de água de 190 l/m³ mostrou ser o teor mais adequado para os materiais e concretos empregados nesta pesquisa. / Surface wear is one of the most frequent pathologies in concrete floors. The presence of such pathological manifestation from the abrasive process is very disturbing, since it implies high costs to repair or replace the damaged concrete. Therefore, studies that seek to evaluate the influence of the proportioning and type of some materials that constitute the mixture proportions of concrete, commonly used on floors, are considered extremely relevant, in order to reduce the tendency of surface wear of composites. In this study, factors such as water consumption (175 l/m³, 190 l/m³, 205 l/m³), replacement content of silica fume (0 %, 5 %, 10 %), addition content of polypropylene fibers (0 g/m³, 600 g/m³) and cement type (CP IV; CP V-ARI) were evaluated. The tests used for this assessment were compressive strength, flexural tensile strength, surface hardness by rebound hammer, bleeding and abrasion resistance. The results showed a significant statistic influence of the cement type on all the properties evaluated, with the cement CP V-ARI presenting a better performance compared to cement CP IV, considering the same w/b ratio (0.53). The water consumption factor, maintaining a constant w/b ratio, showed significant influence on the flexural tensile strength and abrasion resistance of concrete, and, in addition, we could observe a similar behavior for both properties with respect to this parameter of control. Regarding the replacement content of silica fume, it is observed that this factor promoted significant effect on the mechanical properties, which was expected, on the surface hardness and bleeding; however, there was no influence on the abrasion of the cementitious composites. The addition of polypropylene microfibers significantly decrease the surface hardness by rebound hammer, without altering any other property evaluated. The results verified for the wear showed an important relationship with the mechanical properties of concrete. The finishing process as a form of surface treatment seems to be effective in controlling the abrasive wear, since it may have minimized the effect of bleeding on the surface of cementitious composites. The water consumption of 190 l/m³ showed to be the most appropriate content for the materials and concrete used in this research.
16

Impacto da Utilização de Pavimentação Permeável em Áreas Urbanas na Recuperação de Bacias Hidrográficas / Use of Impact Permeable Paving in Urban Areas in Recuperção Watershed

Santos, Cristiano de Assumpção 07 April 2016 (has links)
Made available in DSpace on 2017-07-10T15:14:38Z (GMT). No. of bitstreams: 1 Cristiano.pdf: 1521067 bytes, checksum: 8be179f3b8b51910029f0a61831b2fc6 (MD5) Previous issue date: 2016-04-07 / Urbanization and the disorderly occupation of cities have created many environmental problems, ranging from floods to climate change in large urban centers. Among the causes of these occurrences is mainly soil sealing in cities, that occurs by interference and man's need to use more space. The more waterproofed the surface of urban areas, higher runoff, and this, in turn, due to the adopted public politics and the lack of planning, are transferred to adjacent watersheds, causing, these problems such as floods and silting of rivers. The impermeabilized surfaces end up affording a smaller charge of watersheds, transferring to other river basins the amount of water that it should be restored in the region, that way impair the recovery of the basins where the percolations occur. This study is a comparison between two existing technologies in commercially known market as "paver" and "draining floor", and point which of these can help in the recovery of watersheds and, consequently, reduce the problems caused by surface runoff in urban areas. To reach the result precipitations were simulated using a sprinkler infiltrometer in intensities corresponding to 45mm.h-1, 60mm.h-1 and 90mm.h-1, and occurred in lysimeters where the coverages match the public walks characteristics using the technologies to be analyzed as ground cover. This experiment showed that the permeable concrete parts (draining floor) and concrete parts gaskets extended (paver) has percolation rate likened to grass cover and thus can be used as technologies for water infiltration into the soil aiding in the recovery of watersheds in urban areas / A urbanização e a ocupação desordenada das cidades criaram diversos problemas ambientais, que vão desde enchentes até alterações climáticas nos grandes centros urbanos. Entre as causas destas ocorrências está, principalmente, a impermeabilização dos solos nas cidades, que ocorre pela interferência e necessidade do homem em utilizar mais espaço. Quanto mais impermeabilizada a superfície das regiões urbanas, maior o escoamento superficial, e este, por sua vez, devido às políticas públicas adotadas e à falta de planejamento, são transferidos para bacias adjacentes, trazendo problemas a estas, como enchentes e assoreamentos dos rios. As superfícies impermeabilizadas acabam proporcionando uma menor recarga das bacias hidrográficas, transferindo para outras bacias a quantidade de água que deveria ser reposta naquela região, desta forma prejudicam a recuperação das bacias onde ocorrem as percolações. O presente estudo faz um comparativo entre duas tecnologias existentes no mercado comercialmente conhecidos como paver e o piso drenante , e apontará qual destas pode auxiliar na recuperação das bacias hidrográficas e, consequentemente, reduzir os problemas causados pelo escoamento superficial nas regiões urbanas. Para chegar ao resultado foram simuladas precipitações utilizando um infiltrômetro de aspersão em intensidades correspondentes à 45 mm.h-1, 60 mm.h-1 e 90 mm.h-1, e ocorreram em lisímetros onde as coberturas correspondem as características de passeios públicos utilizando as tecnologias a serem analisadas como cobertura de solo. Este experimento apontou que as peças de concreto permeável (piso drenante) e as peças de concreto com juntas alargadas (paver) têm taxa de percolação assemelhada a cobertura de grama e desta forma podem ser utilizadas como tecnologias para infiltração de água no solo auxiliando na recuperação das bacias hidrográficas das zonas urbanas.
17

Dimensionamento e análise numérica de pisos industriais de concreto. / Design and numerical analysis of concrete industrial floors.

Priscilla Formoso da Cunha 28 June 2013 (has links)
Fundação Carlos Chagas Filho de Amparo a Pesquisa do Estado do Rio de Janeiro / Os pisos industriais devem atender aos critérios de segurança, funcionalidade e durabilidade das estruturas de concreto. A fim de analisar o desempenho de placas de concreto apoiadas sobre base elástica quando submetidas a ações diretas e indiretas, foram elaborados diversos modelos analíticos e empíricos. Com o avanço tecnológico e o advento de softwares desenvolvidos através de processos numéricos como o método dos elementos finitos (MEF), a aplicação desses modelos foi facilitada. Este trabalho aborda os métodos de cálculo existentes e utilizados na execução dos projetos estruturais de pisos industriais de concreto. / The industrial floors must meet the criteria of security, functionality and durability of concrete structures. In order to analyze the performance of concrete slabs supported on elastic foundation when subjected to direct and indirect actions, were developed several analytical and empirical models. With advances in technology and the advent of software developed by numerical processes such as finite element method, the application of these models was facilitated. This paper presents the calculation methods used in the implementation of structural designs of concrete industrial floors.
18

Dimensionamento e análise numérica de pisos industriais de concreto. / Design and numerical analysis of concrete industrial floors.

Priscilla Formoso da Cunha 28 June 2013 (has links)
Fundação Carlos Chagas Filho de Amparo a Pesquisa do Estado do Rio de Janeiro / Os pisos industriais devem atender aos critérios de segurança, funcionalidade e durabilidade das estruturas de concreto. A fim de analisar o desempenho de placas de concreto apoiadas sobre base elástica quando submetidas a ações diretas e indiretas, foram elaborados diversos modelos analíticos e empíricos. Com o avanço tecnológico e o advento de softwares desenvolvidos através de processos numéricos como o método dos elementos finitos (MEF), a aplicação desses modelos foi facilitada. Este trabalho aborda os métodos de cálculo existentes e utilizados na execução dos projetos estruturais de pisos industriais de concreto. / The industrial floors must meet the criteria of security, functionality and durability of concrete structures. In order to analyze the performance of concrete slabs supported on elastic foundation when subjected to direct and indirect actions, were developed several analytical and empirical models. With advances in technology and the advent of software developed by numerical processes such as finite element method, the application of these models was facilitated. This paper presents the calculation methods used in the implementation of structural designs of concrete industrial floors.
19

Análise dinâmica e controle de vibrações de pisos de edificações submetidos a atividades humanas rítmicas.

Cássio Marques Rodrigues Gaspar 05 August 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Um aumento crescente dos problemas estruturais associados à vibração excessiva de pisos de edificações de estruturas mistas (aço-concreto) e de concreto armado devido a atividades humanas rítmicas constitui a principal motivação para o desenvolvimento de uma metodologia de projeto respaldada na obtenção da resposta dinâmica de pisos mistos (aço-concreto) e de concreto armado, quando submetidos a cargas dinâmicas humanas rítmicas. Para tal, os modelos estruturais estudados baseiam-se em pisos de edificações mistas (aço-concreto) e de concreto armado submetidos a aulas de ginástica aeróbica. São empregadas técnicas usuais de discretização, via método dos elementos finitos (MEF), por meio do programa ANSYS. Um estudo paramétrico foi realizado sobre os modelos estruturais investigados e foram obtidos valores elevados para as acelerações de pico violando os critérios de projeto e indicando níveis de vibrações excessivas. Considerando-se os aspectos mencionados anteriormente foi desenvolvida uma estratégia com base em alternativas viáveis para o controle estrutural, objetivando a atenuação das vibrações excessivas a partir da instalação de atenuadores dinâmicos sincronizados (ADS) nos pisos analisados. / The increasing incidence of building vibration problems due to human rhythmic activities led to a specific design criterion to be addressed in structural design. This was the main motivation for the development of a design methodology centred on the composite (steel-concrete) and reinforced concrete building floors dynamic response when submitted to dynamic loads due to human rhythmic activities. The structural system is composed by a composite (steel-concrete) and a reinforced concrete building floor subjected to aerobics. The proposed analysis methodology adopted the usual mesh refinement techniques present in the finite element method (FEM) simulations implemented in the ANSYS program. An extensive parametric study was developed and the results have demonstrated that the analysed composite and reinforced floor have presented high values of accelerations and excessive vibrations. Considering all aspects mentioned before, it was developed a structural control strategy aiming to reduce the floor excessive vibrations. Finally, an investigation was performed based on some structural control alternatives for attenuating excessive vibrations using Tuned Mass Damper (TMD) systems.
20

Análise dinâmica e controle de vibrações de pisos de edificações submetidos a atividades humanas rítmicas.

Cássio Marques Rodrigues Gaspar 05 August 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Um aumento crescente dos problemas estruturais associados à vibração excessiva de pisos de edificações de estruturas mistas (aço-concreto) e de concreto armado devido a atividades humanas rítmicas constitui a principal motivação para o desenvolvimento de uma metodologia de projeto respaldada na obtenção da resposta dinâmica de pisos mistos (aço-concreto) e de concreto armado, quando submetidos a cargas dinâmicas humanas rítmicas. Para tal, os modelos estruturais estudados baseiam-se em pisos de edificações mistas (aço-concreto) e de concreto armado submetidos a aulas de ginástica aeróbica. São empregadas técnicas usuais de discretização, via método dos elementos finitos (MEF), por meio do programa ANSYS. Um estudo paramétrico foi realizado sobre os modelos estruturais investigados e foram obtidos valores elevados para as acelerações de pico violando os critérios de projeto e indicando níveis de vibrações excessivas. Considerando-se os aspectos mencionados anteriormente foi desenvolvida uma estratégia com base em alternativas viáveis para o controle estrutural, objetivando a atenuação das vibrações excessivas a partir da instalação de atenuadores dinâmicos sincronizados (ADS) nos pisos analisados. / The increasing incidence of building vibration problems due to human rhythmic activities led to a specific design criterion to be addressed in structural design. This was the main motivation for the development of a design methodology centred on the composite (steel-concrete) and reinforced concrete building floors dynamic response when submitted to dynamic loads due to human rhythmic activities. The structural system is composed by a composite (steel-concrete) and a reinforced concrete building floor subjected to aerobics. The proposed analysis methodology adopted the usual mesh refinement techniques present in the finite element method (FEM) simulations implemented in the ANSYS program. An extensive parametric study was developed and the results have demonstrated that the analysed composite and reinforced floor have presented high values of accelerations and excessive vibrations. Considering all aspects mentioned before, it was developed a structural control strategy aiming to reduce the floor excessive vibrations. Finally, an investigation was performed based on some structural control alternatives for attenuating excessive vibrations using Tuned Mass Damper (TMD) systems.

Page generated in 0.0538 seconds