• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 190
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 198
  • 135
  • 80
  • 63
  • 42
  • 38
  • 34
  • 33
  • 26
  • 24
  • 23
  • 23
  • 22
  • 21
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Versus: Is it possible to talk about an error? The culturally induced error in the Peruvian legislation / Versus: ¿Es posible hablar de error? El error culturalmente condicionado en el Perú

Villavicencio, Felipe, Meini, Iván 25 September 2017 (has links)
Cultural diversity is one of the biggest challenges that contemporary Law is facing. From this state of things, the penal regulation takes particular relevance, due to its burdensome towards who has committed a crime. A question arises about if it is possible to condemn someone due to the valoration that a different culture made about a specific behavior.In the present versus, there is a discussion about how to understand article 15 of the peruvian Criminal Code, and if the option chosen by the national system of justice is suitable to face the aforementioned problem. / La diversidad cultural es uno de los mayores desafíos que el Derecho contemporáneo afronta. Desde este estado de cosas, cobra particular relevancia laregulación penal, al ser la más gravosa para quien comete un delito. Surge la pregunta sobre si es posible condenar a alguien por la valoración que hizo una cultura que no es la propia de una conducta.En el presente versus, se discute acerca de cómo entender el artículo 15 del Código Penal, y si la opción que ha adoptado el ordenamiento nacional es idónea para abordar el problema mencionado.
82

Determinação dos coeficientes e avaliação das equações de desempenho de condicionadores de ar com vazão de refrigerante variável por Régis Altafini Machado

Machado, Regis Altafini January 2014 (has links)
Neste trabalho é feita uma simulação energética de um prédio de escritórios em Porto Alegre, utilizando um equipamento de ar condicionado de vazão de refrigerante variável (VRF) presente no exemplo do programa simulador (EnergyPlus). Com a carga térmica média (13.600 W) das cargas térmicas resultantes em cada zona térmica, se obteve um equipamento de ar condicionado comercial (unidade interna) com potência (14.000 W) que suprisse a carga térmica média. Através das tabelas do fabricante e do ajuste de curvas são encontradas as equações de desempenho do equipamento comercial e são traçados as curvas características. A seguir é feita uma nova simulação no prédio de escritórios, utilizando o equipamento comercial e comparando resultados com a simulação do equipamento de ar condicionado do exemplo como referência. São comparados os valores de consumo energético da edificação, cargas térmicas das serpentinas de expansão direta de resfriamento e de aquecimento e horas em que a temperatura da zona fica fora do ajuste do termostato no ano. A simulação demonstra que o equipamento VRF comercial (68.297,38 kWh) consome menos energia que o VRF do modelo do EnergyPlus (71.901,99 kWh). / In this dissertation is made an energy simulation of an office building in Porto Alegre, using a variable refrigerant flow air-conditioning (VRF) in this example model of the simulator program (EnergyPlus). With the average thermal load (13.600 W) of thermal loads resulting in each thermal zone, it got a commercial air conditioning unit (Internal unit) VRF with power (14.000 W) that provided the thermal loads of each zone. Through the tables of the manufacturer and the fitting curves are found performance equations of commercial device and their characteristics curves are plotted. The following is made a new office building simulation, using the commercial device and comparing the simulation results with the air conditioning of the example model as a reference. For the comparison are used the values of energy consumption building, the direct expansion cooling coil heat load, the direct expansion heating coil and the annual hours when the temperature zone was outside of set point the thermostat. The simulation shows that the VRF commercial equipment consumes less energy (68.297,38 kWh) than the VRF equipment of EnergyPlus model (71.901,99 kWh).
83

Estudo da eficiência energética de um condicionador de ar por compressão de vapor integrado a um sistema de resfriamento evaporativo direto por aspersão

Gilberto Elias da Silva 17 March 2012 (has links)
Este trabalho apresenta o resultado do estudo realizado sobre o ganho energético do emprego integrado do sistema de resfriamento evaporativo direto por aspersão com o sistema de compressão de vapor, em uma unidade condensadora de condensação a ar, com trocador de calor do tipo aletado. O sistema de compressão de vapor atualmente é o mais utilizado para condicionamento do ar em aplicações de conforto e processos, suas unidades condensadoras podem ser tanto de condensação a ar quanto de condensação a água. Estes sistemas apesar de sua consagrada aplicação são grandes vilões de consumo de energia. Uma alternativa econômica para minimizar este impacto é o emprego do resfriamento evaporativo como pré-resfriador do ar no sistema convencional. Este fluxo de ar resfriado é utilizado na entrada da unidade condensadora do ciclo de compressão de vapor com o objetivo de reduzir o trabalho realizado pelo compressor, através da redução da temperatura de condensação do ciclo frigorífico aumentando o Coeficiente de Performance Operacional (COP). No entanto sua aplicação efetiva em unidades condensadoras a ar com trocador do tipo aletado ainda geram muitas dúvidas, quanto sua efetividade e implicações. Tendo em vista este problema foi promovida a integração destes sistemas, analisado sua efetividade. Foram utilizados bicos (aspersores, pulverizadores ou micropulverizadores) que borrifam a água na forma de gotículas ou névoas, acionados por bomba de média pressão. Por meio dos resultados obtidos, pode-se concluir que há uma melhora significativa de desempenho e eficiência do sistema de refrigeração, que utilize um sistema evaporativo direto por aspersão de forma conjugada. / This paper presents the results of the study on the energy gain of the integrated employment of the system of direct evaporative cooling spray system with vapor compression in a condensing unit condensing the air heat exchanger of the finned type. The vapor compression system is currently the most widely used for air conditioning applications and processes of comfort, its condenser units can be either air condensation and condensation water. These systems in spite of its application are allocated villains large power consumption. An economical alternative to minimize this impact is the use of evaporative cooling as a pre-cooler air in the conventional system. This flow of cooling air is utilized at the entrance of the condensing unit of the vapor compression cycle in order to reduce the work of the compressor by reducing the temperature of condensation of the refrigeration cycle by increasing the coefficient operational performance (COP). However their effective implementation in the air condensing units with finned heat exchanger of the type still generate many questions, and their effectiveness and implications. In view of this problem has been promoted the integration of these systems, analyzed its effectiveness. Were used nozzles (nozzles, spray nozzles or microwave) to spray water in the form of droplets or mist, actuated by pressure medium pump. Through the results obtained, it can be concluded that there is a significant improvement in performance and efficiency of the refrigeration system which uses a system of direct evaporative spray conjugated.
84

Determinação de parâmetros de operação de sistema de distribuição de ar frio pelo piso em ambientes de escritórios. / Determination of operation in office rooms with underfloor air distribution system.

Viviane Caroline Abe 31 May 2007 (has links)
ABE, V.C. Determinação de parâmetros de operação de sistema de distribuição de ar frio pelo piso em ambientes de escritórios. 2007. 132 p. Dissertação (Mestrado) - Departamento de Engenharia de Construção Civil da Escola Politécnica da Universidade de São Paulo, São Paulo, 2007. Atualmente, um dos principais requisitos para que um ambiente de escritório atenda plenamente às necessidades de uso e ocupação é a flexibilidade, mas com conforto. O sistema de distribuição de ar frio pelo piso (Underfloor Air Distribution System - UFAD) está sendo utilizado nos edifícios de escritórios para garantir a flexibilização integrada do sistema com o mobiliário. Trata-se de um sistema que fornece ar frio proveniente de um plenum, através de difusores localizados nos painéis do piso elevado. Os difusores de ar podem ser ajustados, ou reposicionados pelos próprios usuários dos ambientes, possibilitando o controle das condições térmicas no entorno próximo, de acordo com suas preferências individuais. Embora o sistema de distribuição de ar pelo piso apresente diversas vantagens com relação ao sistema de distribuição de ar convencional, ainda há falta de informações objetivas e diretrizes de projeto padronizadas, havendo a necessidade de realização de mais pesquisas na área. A introdução da Dinâmica dos Fluidos Computacional (Computational Fluid Dynamics - CFD) apresentou uma alternativa para as pesquisas experimentais relacionadas ao estudo do escoamento do ar. Assim, para o desenvolvimento do presente estudo foram utilizados recursos de dinâmica dos fluidos computacional, com o uso do código FLUENT. O objetivo do presente trabalho é apresentar uma estratégia para a determinação dos parâmetros de operação de sistemas de distribuição de ar pelo piso aplicados a ambientes de escritórios. A estratégia baseiase no estabelecimento de inter-relações entre os principais parâmetros que definem o escoamento do ar em ambientes com o sistema de distribuição de ar pelo piso: a vazão de ar insuflado, a temperatura do ar insuflado e a diferença de pressão entre o plenum pressurizado e o interior do ambiente. O emprego da estratégia possibilita que o projetista identifique as diversas combinações entre os parâmetros de operação que resultem numa mesma condição desejada, permitindo assim a escolha da opção mais satisfatória. / ABE, V.C. Determination of operation parameters of rooms with underfloor air distribution system. 2007. 132 p. Dissertation (Master Course) - Departamento de Engenharia de Construção Civil da Escola Politécnica da Universidade de São Paulo, São Paulo, 2007. Nowadays, one of the main requirements of an office room to fully attend the use and occupation needs is the flexibility, but with comfort. The underfloor air distribution system is being used in the office buildings to guarantee the integrated flexibility of the system with the furniture layout. The system supplies cooled air to the room from a pressurized plenum, passing through air diffusers located in the raised floor panels. The air diffusers can be adjusted or relocated by the room users themselves, making possible the control of the thermal conditions in their surroundings, according to their individual preferences. Though the underfloor air distribution system presents a lot of advantages with regard to conventional overhead distribution systems, there is still a lack of objective information and standardized guidelines, and the necessity of accomplishment of more researches about the subject. The introduction of Computational Fluid Dynamics presented an alternative for the experimental tests related to the study of airflow in rooms. Thus, for the development of the present study a CFD tool was used, the code FLUENT. The purpose of the present work is to develop a strategy for the determination of the operation parameters of an underfloor air distribution system applied to office rooms. The strategy is based on the establishment of interrelations between the main parameters that define the airflow in rooms with the underfloor air distribution system: the input volume flux, the input air temperature and the pressure difference between underfloor plenum and the room. The use of this strategy enables the designer to identify several combinations of the operation parameters that result in one desired condition, allowing the choice of the most satisfactory option.
85

Condições de conforto térmico e desconforto local em salas cirúrgicas. / Thermal comfort and local discomfort conditions in surgical rooms.

Victor Barbosa Felix 20 June 2008 (has links)
Hospitais e demais instalações médicas constituem-se em ambientes complexos, que requerem sistemas de tratamento de ar e de ventilação adequados para o conforto e segurança de pacientes, de pessoal e de visitantes. Em ambientes cirúrgicos as condições de conforto térmico precisam ser as melhores possíveis, para que o cirurgião e a equipe médica trabalhem em condições favoráveis para o sucesso do procedimento cirúrgico. Simultaneamente, os riscos de infecção do paciente e dos profissionais de saúde, causadas por partículas transportadas pelo ar, devem ser minimizados. Neste trabalho foram realizadas avaliações experimentais de condições de conforto térmico e desconforto local em salas cirúrgicas com três diferentes tipos de sistemas de distribuição de ar. O procedimento experimental consistiu de medições e avaliações subjetivas (questionários). As avaliações de condições de conforto térmico foram realizadas segundo os critérios de conforto de Fanger e conforme previsto nas normas ISO 7730 e ASHRAE 55. A aplicação do método de Fanger na avaliação de condições de conforto térmico em salas cirúrgicas mostrou-se adequada, embora seja necessário cuidado especial na sua utilização e na análise dos resultados. Verificou-se que é muito difícil prover condições de conforto térmico para toda a equipe cirúrgica, principalmente devido a fatores pessoais como o tipo de vestimenta e o nível de atividade, bem como de fatores específicos do ambiente cirúrgico, como o calor liberado pelo foco cirúrgico. Os resultados obtidos permitiram verificar que o sistema de fluxo unidirecional apresentou melhores condições de conforto térmico. Esse sistema também apresenta um maior potencial de controle de contaminantes no campo cirúrgico. Finalmente, resultados de estudo comparativo com trabalhos de outros autores mostram valores praticamente iguais de temperaturas equivalentes de conforto térmico em torno de 22°C para todos os membros da equipe cirúrgica. Esse resultado é particularmente útil para avaliar diferentes condições ambientais e pessoais em propiciar condições de conforto térmico aos diferentes membros da equipe cirúrgica. / Hospitals and medical centers are complex environments which request special air treatment and ventilation systems for the comfort and safety of patients, personnel and visitors. In surgical environments the thermal comfort conditions need to be the best as possible in order to the surgeons and the medical team work in favorable conditions for the success of the surgical procedure. Simultaneously, the risks of infection caused by airborne particles should be minimized. In the present work experimental evaluations of thermal comfort and local discomfort conditions were carried out for surgical rooms with three different types of air distribution systems. Measurements and subjective evaluations (questionnaires) were accomplished. The evaluations of thermal comfort conditions were done according to the Fanger comfort criteria and as foreseen in the norms ISO 7730 and ASHRAE 55. The use of the Fanger method in the evaluation of thermal comfort conditions in surgical rooms is appropriate, although it is necessary special care in its use and in the analysis of the results. It was verified that it is very difficult to provide conditions of thermal comfort for the whole surgical team, mainly due to personal factors like clothing and activity level, as well as surgical-specific environmental factors like the heat of the surgical focus. The analysis shows that the unidirectional flow system presented better conditions of thermal comfort. Additionally, this system also presents greater potential of pollutants control in the surgical field. Finally, results of comparative study with other authors\' works show practically same values of equivalent temperatures of thermal comfort around 22°C for all of the members of the surgical team. That result is particularly useful to evaluate different environmental and personal conditions in propitiating conditions of thermal comfort to the different members of the surgical team.
86

Estudo experimental da influência de sistema de ventilação personalizada instalado na poltrona na dispersão de partículas expiratórias em cabine de aeronave. / Experimental study about the influence of personalized ventilation system installed on armchair in the dispersion of expiratory particles in aircraft cabin.

Paulo Rogério Celline 28 April 2017 (has links)
Cabines de aeronaves vêm sendo desenvolvidas de modo a tornar o ambiente a bordo mais aceitável e confortável para os seus usuários. No presente trabalho, a influência de sistema de ventilação personalizada instalado na poltrona na dispersão de partículas expiratórias foi estudada em um mock-up de 12 lugares, que reproduz o interior de uma aeronave comercial com quatro poltronas por fileira. Os ensaios foram realizados com temperatura do ar insuflado na cabine a 18°C, correspondendo a uma leve sensação de frio, e temperatura do ar insuflado pelo sistema personalizado a 24°C com vazão de 3,0 l/s. As partículas simulando uma pessoa espirrando foram injetadas em dois pontos no fundo da cabine, respectivamente, na poltrona próxima da fuselagem e naquela perto do corredor, a 1,10m do piso, que corresponde à região de respiração. A contagem de partículas foi realizada nos assentos da fileira imediatamente à frente do ponto de injeção das partículas, ou seja, na fileira do meio do mock-up, onde se encontra instalado o sistema de ventilação personalizada, respectivamente, na poltrona próxima da fuselagem e naquela perto do corredor. Medições para o mapeamento dos perfis de temperaturas e de velocidades do ar também foram realizadas. Os resultados mostraram que a dispersão de partículas sofre forte influência do sistema de ventilação personalizada e do ponto de injeção de partículas. A quantidade de partículas expiratórias na cabine sempre foi maior quando a injeção foi feita pelo assento junto ao corredor. Isto ocorre devido ao sistema de ventilação por mistura da cabine, com exaustão do ar pela parte inferior próximo da fuselagem. O sistema personalizado avaliado no assento próximo da fuselagem e junto do corredor foi capaz de reduzir, respectivamente, em 40% e 65% a quantidade de partículas expiratórias na zona de respiração dos ocupantes destas poltronas. Adicionalmente, quando o sistema personalizado está funcionando junto ao corredor, a redução das partículas em toda a fileira é de quase 60% em comparação ao sistema personalizado desligado. / Aircraft cabins have been developed in order to make the onboard environment more acceptable and comfortable for their users. In the present work, the influence of a personalized ventilation system installed on the armchair in the dispersion of expiratory particles was studied in a 12-seat mock-up, which reproduces the interior of a commercial aircraft with four seats per row. The tests were performed with inlet air temperature into the cabin at 18°C, corresponding to a slight cold sensation, and inlet air temperature of the customized system at 24°C with a flow rate of 3.0 l/s. Particles simulating a person sneezing were injected at two points in the bottom of the cabin, respectively, in the seat near the fuselage and in the one near the corridor, 1.10m from the floor, which corresponds to the breathing zone. Particle counting was carried out in the row seats immediately in front of the particles\' injection point, i.e. in the middle row of the mock-up, where the custom ventilation system is installed, respectively, in the seat near the fuselage and in that one near the aisle. Measurements for the mapping of temperature and air velocities profiles were also performed. The results showed that the particle dispersion is strongly influenced by the custom ventilation system and the particle injection point. The amount of expiratory particles in the cabin was always greater when the injection was done by the seat near the aisle. This occurs due to the mixing ventilation system of cabin, with air exhaust located nearby the fuselage low part. The personalized ventilation evaluated on the fuselage seat and the aisle seat was able to reduce by 40% and 65%, respectively, the amount of expiratory particles in the breathing zone in these seats. Moreover, when the custom system is working along the corridor, the particle reduction across the row is nearly 60% less compared to the custom system, when it is off.
87

Resfriamento de ambientes utilizando sistema regenerativo com leito de pedras

Cavalcanti, Eduardo J. Cidade 02 August 2018 (has links)
Orientador : Caio Glauco Sanchez / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-02T07:50:13Z (GMT). No. of bitstreams: 1 Cavalcanti_EduardoJ.Cidade_D.pdf: 5685689 bytes, checksum: 8ec4e75f6488bbefb53d768d505269cb (MD5) Previous issue date: 2001 / Resumo: Foi avaliado um sistema de refrigeração não-convecional de maneira a se verificar sua real possibilidade como um sistema alternativo aos sistemas de resfriamento convencionais de ambientes como o aparelho unitário de ar-condicionado. Sistemas de refrigeração não-convecionais são alternativas para refrigerar ambientes, principalmente durante o verão, de forma mais econômica. O sistema regenerativo de leito de pedras úmido é uma unidade de alta eficiência de troca térmica, onde o ar ambiente transfere calor escoando através do leito de pedras. Esse sistema é utilizado em escolas do sul da Austrália devido a seu desempenho tanto no verão (resfriando), quanto no inverno (aquecendo) com baixo custo operacional (apenas o consumo de ventilador) e com ar sempre renovado. Sua desvantagem é o aumento excessivo da umidade do ar, o que pode se tornar uma vantagem em regiões secas. O trabalho foi composto de duas partes. A primeira foi o desenvolvimento de um modelo teórico para simulação do sistema e verificação do seu desempenho e estimativa da influência dos parâmetros: fração de vazio do regenerador, ciclos de operação, temperatura da água de alimentação do resfriador evaporativo, calor específico do material utilizado como regenerador térmico. A segunda parte foi a determinação experimental do desempenho de um protótipo construído na Faculdade de Engenharia Mecânica da UNICAMP através da determinação experimental da efetividade do regenerador e do resfriador evaporativo (componentes dos sistema estudado). A simulação do modelo teórico foi importante para otimizar o projeto térmico do sistema e verificar o seu desempenho de acordo com os parâmetros analisados. Foi realizada análise da sensibilidade dos parâmetros citados e foi observada uma forte influência da fração de vazio do regenerador, ciclos de operação e do calor específico do material utilizado como regenerador térmico no sistema. A temperatura da água de alimentação do resfriador evaporativo possui uma influência desprezível no sistema. Os dados do modelo e as medidas experimentais foram comparados e foi observado uma melhor precisão para ciclos pequenos, principalmente para ciclos de 5 minutos, do que para ciclos maiores / Abstract: A passive cooling system was evaluated in order to verify, its real possibility as an alternative system to the conventional cooling systems like single air conditioning unit. Passive cooling system can be an alternative for building cooling system, mainly during the summer, m a more econOIIDC way. The wet rock bed regenerative system presents a high heat exchanger effectiveness, due to the heat transfer between atmospheric air and water flowing in matrix of rock bed. That system is commonlY applyed in schools of the south Australia due to its good performance in the summer (cooling), as in the winter (heating) with low operational cost Gust the fan consumption) and with air always renewed. 1ts disadvantage is the excessive increase of the air humidity, otherwise this fact becomes an advantage for dry environrnents. The work was composed by two parts. The first one was the development of a theoretical model for the system simulation to verify its performance and the influence of the parameters: void fraction of regenarator, period of time, water temperature, specific heat of the regenerator material. The second part was the experimental determination of the performace of a prototype system built in the college of Mechanical Engineering at UNlCAMP through experimental determination of regenerator and evaporative cooler effectiveness (components ofthe studied system). The theoretical model simulation was important for thermal design optimization and verification of the system performance according to analyzed parameters. Sensibility analysis was made for the cited parameters and was observed a high influence of void fTaction of regenarator, period of time and specific heat of the regenerator material on the system. The feeding water temperature of evaporative cooler has a negligible influence on the system. The data of the mode! and the experimental measures were compared and was observed a better accuracy for small period main1y for period of 5 minutes as larger period / Doutorado / Termica e Fluidos / Doutor em Engenharia Mecânica
88

Implementação de uma bancada de ensaios para analise de estrategias de controle de sistemas de refrigeração e ar condicionado / Conditioned air system control analysis with termical storage in a ice storage

Carvajal Florez, Fabio Alejandro 27 February 2004 (has links)
Orientador: Luiz Felipe Mendes de Moura / Made available in DSpace on 2018-08-04T03:19:09Z (GMT). No. of bitstreams: 1 CarvajalFlorez_FabioAlejandro_D.pdf: 13507897 bytes, checksum: 763803f559424480cb0dc2207f08a244 (MD5) Previous issue date: 2004 / Resumo: No presente trabalho se realiza o estudo do controle da válvula de expansão e da velocidade de rotação do motor do compressor para um sistema de ar condicionado com armazenamento térmico em banco de gelo. Utilizando os princípios de projeto térmico, projeto eletrônico, programação de computadores e técnicas de controle procuram-se o aumento da eficiência do sistema. Neste controle propostos usou-se a lógica difusa. Inicialmente controlou-se o grau de superaquecimento através do controle da abertura da válvula de expansão e trabalhando o compressor em sua rotação máxima. Em seguida foi implementado um controle que trabalha regulando simultaneamente a velocidade do compressor e a abertura da válvula de expansão / Abstract: In this work is realized a control analysis ofthe expansion valve and the rotacional speed of the compressor engine for an air conditioning system with thermal storage in an ice storage tank. The thermal project, electronical project, computer programming and control technics are integrated to increase the performance of the system. To implement the proposed controls the logic fuzzy is used. Inicially, the refrigerant superheat was controlled through the expansion valve with the compressor working at highest rotational speed. Then, it was implemented the control regulating simultananeously the compressor speed and the expansion valve / Doutorado / Termica e Fluidos / Doutor em Engenharia Mecânica
89

Ensayos espaciados y claves de extinción: manipulaciones para reducir la renovación del miedo condicionado

Lira Ampuero, Daniela 05 January 2016 (has links)
Psicóloga / Utilizando un diseño de renovación ABC se realizó un experimento que buscó evaluar los efectos, tanto en conjunto como por separado, del entrenamiento espaciado de extinción y de claves de extinción en las respuestas de miedo condicionado en ratas, los cuales fueron evaluados durante la extinción y la renovación del miedo condicionado. Se utilizó un diseño experimental en el cual se manipuló la duración de los intervalos entre ensayos (Corto vs. Largo) y el uso de claves de extinción (Clave vs. Sin Clave) como técnicas potenciales para la prevención de la renovación del miedo extinguido. Cuatro grupos: Sin Clave-Corto, Clave-Corto, Sin Clave-Largo, Clave-Largo recibieron el mismo tratamiento de adquisición, pero se diferenciaron en el tratamiento de extinción. Los grupos de la condición Corto tenían un intervalo entre ensayos de 6 s mientras que los grupos de la condición Largo tenían intervalos entre ensayos de 600 s. Por otra parte, los grupos de la condición Clave fueron testeados con una clave presente durante la extinción la cual también fue presentada durante los test, mientras que los grupos de la condición Sin Clave también fueron testeados con una clave diferente a la usada durante la extinción (i.e., clave de relleno). Los resultados muestran un efecto estadísticamente significativo del intervalo entre ensayos, sin embargo, no se encontraron efectos significativos del uso de claves de extinción
90

[pt] ANÁLISE TEÓRICO-EXPERIMENTAL DE UM DESUMIDIFICADOR DE AR USANDO TRI-ETILENO GLICOL / [en] THEORETICAL AND EXPERIMENTAL ANALYSIS OF AN AIR DEHUMIDIFIER USING TRIETHYLENE GLYCOL

31 October 2011 (has links)
[pt] Como parte de um sistema solar de condicionamento de ar por resfriamento evaporativo, foi projetado e construindo um desumidificador de ar utilizando tri-etileno glicol como agente higroscópio líquido. O modelo teórico desenvolvido, baseado no procedimento adotado para cálculo de torres de resfriamento. Levou em consideração o abaixamento de pressão de vapor na superfície líquido-gás assim como o calor de mistura de tri-etileno glicol e água. Os dados experimentais obtidos concordam satisfatoriamente com os resultados previstos pelo modelo teórico proposto, dentro das faixas de vazão pesquisadas. Uma correlação semi-empírica foi desenvolvida para cálculo dos coeficientes de difusão de desumidificadores de ar como função das vazões das fases líquida e gasosa. Finalmente é sugerido um procedimento para projeto de desumidificadores de ar de características semelhantes ao modelo proposto. / [en] As part of solar evaporative cooling air conditioning system, using tri-ethylene glicol as a liquid dehumidifier, an absortion tower was designed and built for drying air. The theory of heat and mass transfer between liquid and gas was developped following the same procedure as usually adopted for cooling tower calculations.The lowering of vapor pressure and the heat of solution were taken into account. Experimental data agree reasonably with theory within a wide range of flow rates. A correlation was developped relating mass transfer coefficients to liquid and gás flow rates. A procedure is finally suggested for designing and estimating the performance of na absortion tower.

Page generated in 0.09 seconds