651 |
"Estudos do desenvolvimento e caracterização das ligas Cu-Ni-Pt e Cu-Ni-Sn para fins eletro-eletrônicos" / STUDIES OF THE DEVELOPMENT AND CHARACTERIZATION OF THE Cu-Ni-Pt AND Cu-Ni-Sn ALLOYS FOR ELETRO-ELECTRONIC USESSilva, Luis Carlos Elias da 04 October 2006 (has links)
O Cu e suas ligas têm diferentes aplicações na sociedade moderna devido as excelentes propriedades elétricas, condutividade térmica, resistência à corrosão dentre outras propriedades. Estas aplicações podem ser em válvulas, tubulações, panelas para absorção de energia solar, radiadores para automóveis, condutores de corrente e eletrônico, elementos de termostatos e partes estruturais de reatores nucleares, como, por exemplo, bobinas para campo toroidal para um reator de fusão nuclear. Dentre as ligas utilizadas em reatores nucleares, podemos destacar Cu-Be, Cu-Sn e Cu-Pt. O Ni e o Co, freqüentemente são adicionados às ligas de Cu para que a solubilidade seja deslocada para temperaturas mais elevadas com relação aos sistemas binários de Cu-Sn e Cu-Pt. A adição de Ni-Pt ou Ni-Sn ao Cu em porcentagens iguais ou inferiores a 1,5 % aliado a tratamentos termos-mecânico alteram as propriedades do Cu. Estudamos neste trabalho sete diferentes ligas: três ligas de Cu-Ni-Pt 1 (97,99 % Cu - 1,55 % Ni - 0,46 % Pt), 2 (99,33 % Cu - 0,23 % Ni -0,43 % Pt) 3 (98,01 % Cu - 0,48 % Ni - 1,51 % Pt); três ligas de Cu-Ni-Sn 4 (98,31% Cu - 1,12 % Ni - 0,58 % Sn), 5 (98,79 % Cu 0,57 % Ni - 0,65 % Sn), 6 (98,39% Cu 0,46 % Ni 1,16 % Sn) e Cu eletrolítico 0 (0,0058 % Pb - 0,0007 % Fe - 0,0036 % Ni - 0,0024 % Ag). As referentes ligas foram desenvolvidas a partir de um forno a arco voltaico e passaram por tratamentos termo-mecânicos pré-determinados. As microestruturas foram analisadas diretamente por microscopia óptica e microscopia eletrônica de varredura / EDS e indiretamente por medidas de dureza Vickers e condutividade elétrica. O objetivo deste trabalho, portanto, foi observar e constatar os efeitos da mudança da microestrutura em relação às propriedades dureza e condutividade elétrica. / The Cu and its alloys have different applications in the owed modern society the excellent electric properties, thermal conductivity, resistance to the corrosion and other properties. These applications can be in valves, pipes, pots for absorption of solar energy, radiators for automobiles, current driver, electronic driver, thermostats elements and structural parts of nuclear reactors, as, for example, reels for field toroidal for a reactor of nuclear coalition. The alloys used in nuclear reactors, we can highlight Cu-Be, Cu-Sn and Cu-Pt. Ni and Co frequently are added to the Cu alloys so that the solubility is moved for temperatures more elevated with relationship to the binary systems of Cu-Sn and Cu-Pt. The addition of Ni-Pt or Ni-Sn to the Cu in the same or inferior percentages to 1,5% plus thermomechanical treatments changes the properties of the copper. We studied the electric conductivity and hardness Vickers of the Cu-Ni-Pt and Cu-Ni-Sn and compared with the electrolytic Cu. In the proposed flowcharts, breaking of the obtaining of the ingot, we proceeded with thermo mechanical treatments.
|
652 |
Tolerância do tomateiro à salinidade sob fertirrigação e calibração de medidores de íons específicos para determinação de nutrientes na solução do solo e na planta. / Tolerance of tomato to salinity under fertigation and calibration of cardy-ion meters for determination of nutrients in the soil solution and plant.Blanco, Flávio Favaro 08 March 2004 (has links)
A concentração de sais na água é um dos principais aspectos a ser observado para se definir uma estratégia de manejo da irrigação, podendo levar a prejuízos pela salinização do solo, com conseqüente redução do rendimento das culturas. Visto que culturas tolerantes à salinidade apresentam maiores teores foliares de certos nutrientes, então a adubação em culturas sensíveis poderia ser conduzida de modo a elevar os teores destes nutrientes nas folhas, promovendo aumento da tolerância da cultura aos sais. Este trabalho teve o objetivo de estudar os efeitos de três doses de N e K na tolerância da cultura do tomateiro à salinidade, bem como avaliar a performance de medidores de íons específicos (MIE) na determinação de nutrientes na solução do solo e na seiva da planta. Mudas de tomateiro, híbrido Facundo, foram transplantadas em 23/10/2001 em vasos contendo 60 kg de solo franco-argilo-arenoso, no espaçamento de 1,0 x 0,5 m, em um ambiente protegido com cobertura de polietileno. Os tratamentos foram compostos pela combinação de três níveis de N (7,5; 15,0 e 22,5 g planta-1) e três níveis de K (8, 16 e 24 gK2O planta-1) aplicados via fertirrigação por gotejamento, no esquema fatorial 3x3 com cinco repetições, sendo que à água de irrigação foram adicionados os sais cloreto de sódio e cloreto de cálcio para obtenção de condutividade elétrica da água de 9,5 dS m-1. Foram realizadas coletas da solução do solo e da seiva do pecíolo para determinações dos nutrientes pelos MIE, cujos valores foram comparados com as determinações pelos métodos-padrões. Não foram observados efeitos significativos dos tratamentos sobre o desenvolvimento e a produtividade das plantas, bem como sobre a qualidade dos frutos. As concentrações de nutrientes na solução do solo determinadas com os MIE apresentaram boa correlação com as determinações pelos métodos-padrões, e as concentrações de nutrientes na seiva do pecíolo foram bem correlacionadas aos teores na matéria seca das folhas. A condutividade elétrica e a concentração iônica na solução do solo não puderam ser estimadas a partir dos valores medidos no extrato de saturação ou na solução 1:2 apenas pela correção de umidade, com exceção do K e Na, cujas estimativas foram satisfatórias para baixas concentrações destes elementos na solução do solo. / The concentration of salts in the water is one of the main aspects to be observed to define a strategy of irrigation management, which could take to damages due to the soil salinization, with consequent reduction of crops yield. Once tolerant crops to salinity present larger tenors of some nutrients in the leaves, then the fertilizing in sensitive crops could be conducted in order to increase the tenors of these nutrients in the leaves to increase the crop tolerance to salts. This work had the objective of studying the effects of three doses of N and K in the tomato tolerance to salinity, as well as to evaluate the performance of cardy-ion meters (CIM) in the determination of nutrients in the soil solution and in the sap of the plant. Tomato seedlings, hybrid Facundo, were transplanted in 10/23/2001 in vases containing 60 kg of a sandy-clay-loam soil, spaced 1.0 x 0.5 m, in a greenhouse covered with polyethylene film. The treatments were composed by the combination of three levels of N (7.5; 15.0 and 22.5 g plant-1) and three levels of K (8, 16 and 24 gK2O plant-1) applied by drip fertigation, in the 3x3 factorial scheme with five replications. Salts (sodium chloride and calcium chloride) were added to the irrigation water for obtaining an electric conductivity of 9.5 dS m-1. Soil solution and petiole sap were collected for determinations of the nutrients with the CIM, whose values were compared with the determinations by the standard methods. Significant effects of the treatments were not observed for the development and yield of the plants, as well as for the fruits quality. The concentrations of nutrients in the soil solution determined with CIM showed good correlations with the determinations by the standard methods, and the concentrations of nutrients in the petiole sap were well correlated to the tenors in the dry matter of the leaves. The electric conductivity and the ionic concentration in the soil solution could not be estimated from the measured values in the saturation extract or in the solution 1:2 only by the correction of the water content, except for K and Na, whose estimates were satisfactory for low concentrations of these elements in the soil solution.
|
653 |
Propriedades de retenção e condução da água no solo determinadas sob condições de campo / Water retention and conduction properties assessed in field conditionsGimenes, Fernando Henrique Setti 16 February 2017 (has links)
As propriedades hidráulicas do solo de interesse são a curva de retenção da água no solo, a condutividade hidráulica e difusividade hidráulica, ambas em função do conteúdo de água no solo. Estas propriedades dependem do tamanho, forma, distribuição e grau de interconexões dos poros. O método do perfil instantâneo é um dos métodos mais utilizados na determinação da condutividade hidráulica do solo não saturado pela sua simplicidade experimental e matemática. Assim, este projeto visa avaliar a) a condutividade hidráulica em função do conteúdo de água em dois solos bem distintos estruturalmente pelo método do perfil instantâneo, com e sem a remoção de horizontes sobrejacentes, estimando o conteúdo de água via curvas de retenção determinadas em laboratório e em campo, e b) o sistema poroso do solo por meio de técnicas de análise de imagens e correlacionar os resultados à condutividade hidráulica do solo não saturado obtido pelo método do perfil instantâneo. O experimento foi conduzido em quatro horizontes de um Latossolo e de um Nitossolo. A CRA em campo foi elaborada utilizando-se tensiômetros com manômetro de mercúrio, enquanto que a CRA em laboratório foi determinada com amostras de solo com estrutura indeformada em funis de placa porosa e em câmara de pressão com placa porosa. A condutividade hidráulica não saturada foi determinada pelo método indireto em laboratório e em campo, seguindo a metodologia do método do perfil instantâneo, sem e com a remoção dos horizontes sobrejacentes. De acordo com os resultados obtidos, pode-se concluir que: (a) os valores do conteúdo de água médio à base de volume para cada tensão em campo foram menores que os obtidos em laboratório em praticamente todas as tensões; (b) a eficiência da equação de ajuste da curva de retenção da água foi maior para o método de laboratório; (c) as análises micromorfométricas tenderam a subestimar os valores de área de poro para todas as classes de tamanho de poros e horizontes; (d) a análise micromorfométrica fornece uma estimativa do grau de interconexões do sistema poroso; (e) pequenas mudanças no conteúdo de água no solo afetam o valor de difusividade hidráulica em um grau muito menor que a condutividade hidráulica; e (f) é necessário ter cautela ao utilizar dados de laboratório para representar as condições de campo, visto que os valores de K(θ) foram superestimados pela CRA obtida em laboratório, em relação ao método de campo, ocorrendo de forma mais pronunciada nas menores tensões da água no solo. / The soil hydraulic properties of interest are the soil water retention curve, hydraulic conductivity and hydraulic diffusivity, both as a function of the soil water content. These properties depend on the size, shape, distribution and degree of pore interconnections. The instantaneous profile method is one of the most used methods to determine the unsaturated hydraulic conductivity due to its experimental and mathematical simplicity. Thus, this project aims to evaluate a) hydraulic conductivity as a function of water content in two distinct structured soils by the instant profile method, without/with removal of overlying horizons, estimating the soil water content through retention curves determined in the laboratory and in the field, and b) the soil porous system using image analysis techniques and correlation the results to the unsaturated hydraulic conductivity obtained by the instant profile method. The experiment was conducted on four horizons of a Ferralsols and a Nitisol. The SWRC was made with tensiometers with mercury manometers, while a SWRC in the laboratory was made with undisturbed soil samples in porous plate funnels and in porous plate pressure chamber. The unsaturated hydraulic conductivity was determined by the indirect method in the laboratory and using the instant profile method in the field, without/with removal of the overlying horizons. The conclusions are: (a) the water content for each tension in the field are smaller than those obtained in the laboratory at practically all tensions; (b) the efficiency of the water retention curve fitting equation was greater for the laboratory method; (c) the micromorphometric analysis tended to underestimate pore area values for all pore size classes and horizons; (d) the micromorphometric analysis provides an estimation of the porous system interconnections degree; (e) small changes in soil water content affect the hydraulic diffusion values to a much lower degree than the hydraulic conductivity; and (f) it is necessary to take care in using laboratory data to represent field conditions, since the values of K(θ) were overrated by the laboratory SWRC, compared to the field, more pronounced in smaller water tensions.
|
654 |
Manejo da fertirrigação em ambiente protegido visando o controle da salinidade para a cultura do pepino enxertado / Management of the fertirrigation in protecting environment aiming the control of the salinity for culture of grafted cucumberMedeiros, Pedro Róbinson Fernandes de 18 January 2008 (has links)
Com o intuito de contribuir para os estudos referentes à tolerância e efeitos da salinidade causada por excesso de fertilizantes nas principais culturas exploradas nacionalmente, o presente trabalho teve como objetivos estudar os efeitos de diferentes níveis de salinidade do solo sobre as variáveis fenológicas e de produção do pepino cultivado em vasos e em ambiente protegido, e averiguar se a manutenção da condutividade elétrica em um determinado nível promove incremento da produção quando contrastada com o manejo tradicional da fertirrigação. Este estudo foi conduzido na experimental do Departamento de Engenharia Rural da ESALQ/USP, Piracicaba, SP. Os tratamentos foram compostos da combinação de dois fatores: 6 níveis de salinidade inicial do solo (S1 = 1,5; S2 = 2,5; S3 = 3,5; S4 = 4,5; S5 = 5,5 e S6 = 6,5 dS m-1) e dois manejos de fertirrigação: tradicional (M1) e com controle da condutividade elétrica da solução do solo (M2). O delineamento estatístico adotado foi o de blocos casualizados completos com quatro repetições, ficando os fatores estudados arranjados no esquema fatorial 6 x 2. A salinização inicial do solo se procedeu por meio da aplicação de soluções salinas preparadas a partir de fertilizantes, sendo que a quantidade de sais a ser adicionada foi determinada tomando por base uma curva de salinização artificial obtida previamente em laboratório. A condutividade elétrica da solução foi medida após o término de cada evento de irrigação, utilizando-se extratores com cápsulas porosas. Os resultados mostram que houve efeito significativo, para todos os fatores estudados e para variáveis respostas estudadas, com exceção da variável altura de plantas. O manejo M1 proporcionou uma maior produção de frutos por planta, total e comercial, em relação ao manejo M2. Embora a literatura cite que a cultura do pepino seja moderadamente sensível a salinidade, o valor encontrado para a salinidade limiar (SL), sob condições do referente estudo, ficou bem acima dos níveis encontrados na literatura. / With intention of contributing for the studies regarding the tolerance and effect of the salinity caused by fertilizer excess in the main explored cultures, the present work has had as objective to study the effect of different levels of ground salinity on the phenology variable and of production of the cucumber cultivated in vases and protected environment, and to check if the maintenance of the electric conductivity in one determined level promotes increment of the production when contrasted with the traditional management of fertirrigation. This study was lead in the experimental area of the Department of rural Engineering of ESALQ/USP, Piracicaba, SP. The treatments had been composed of the combination of two factors: 6 levels of initial salinity of the ground (S1 = 1,5; S2 = 2,5; S3 = 3,5; S4 = 4,5; S5 = 5,5 and 6,5 S6 = dS m-1) and two fertirrigation management: traditional (M1) and with control of the electric conductivity of the solution of the soil (M2). The adopted statistical delineation was of complete random blocks with the four repetitions, being the studied factors arranged in factorial project 6 x 2. The initial salinization of the soil was proceeded by means of the application of saline solutions prepared from fertilizers, being that the amount of salt was to be added was determined based a in curve of artificial salinization previously gotten in laboratory. The electric conductivity of the solution was measured after the ending of each event of irrigation, using extracts with porous capsules. The results show that it had significant effect, for all the studied factors and changeable studied answers, except for the changeable height of plants. The M1 management provided a great yield of fruits per plant, total and negatiable, in relation to management M2. Literature states that the culture of the cucumber is moderately sensitive to the salinity, and the value found for the salinity threshold (SL), under conditions of the referring study, was well above of the levels found in the literature.
|
655 |
Teste do suor para diagnóstico de fibrose cística: comparação do teste clássico com o teste simplificado / Sweat test for the diagnosis of cystic fibrosis: comparison between the classic and a simplified testMattar, Ana Claudia Veras 08 June 2010 (has links)
INTRODUÇÃO: apesar da identificação de mais de 1500 mutações para o gene CFTR (cystic fibrosis transmembrane conductance regulator), o teste do suor ainda é o teste diagnóstico para Fibrose Cística (FC). O teste quantitativo de iontoforese por pilocarpina (TQIP) é o padrão-ouro para coleta do suor e análise do cloro, mas está sujeito a erros se não for realizado por técnicos qualificados. Embora a técnica de coleta do suor pelo sistema macroduct® e análise pela condutividade seja simples e tenha boa correlação com os níveis de cloro em estudos prévios, a mesma ainda é considerada como um teste de triagem para FC. O melhor ponto de corte para confirmar ou afastar a FC pelo método da condutividade deve ser ainda estabelecido. OBJETIVOS: comparar os valores de cloro no suor obtidos pelo teste quantitativo da iontoforese pela pilocarpina (teste clássico) com os valores de condutividade do suor obtido pelo sistema de coleta por macroduct® (teste simplificado) em pacientes com e sem FC e em uma amostra aleatória de pacientes em investigação para FC. O custo e o tempo despendidos na execução de cada teste foram também analisados na fase inicial do estudo. MÉTODOS: o teste do suor, pelas duas técnicas, foi realizado simultaneamente em pacientes com e sem FC e posteriormente em pacientes em investigação diagnóstica da doença no período de fevereiro/2006 a outubro/2008. Os pontos de corte para a condutividade para excluir ou diagnosticar FC foram < 75 e ? 90 mmol/L, respectivamente, e para o teste clássico cloro ? 60 e > 60 mmol/L. Na fase inicial da pesquisa (casos com e sem FC) foram utilizadas tabelas de contingência para os cálculos de sensibilidade (S), especificidade (E), valor preditivo positivo (VPP) e negativo (VPN), além do teste exato de Fisher para avaliar a associação entre os testes e a presença ou ausência de FC. Na amostra aleatória de pacientes usou-se a curva ROC também para os cálculos de S, E, VPP e VPN e também para calcular a área sob a curva entre os testes, e, em ambas as fases da pesquisa, para avaliar sua acurácia. Os respectivos intervalos de confiança de 95% (IC95%) também foram analisados. Para avaliação da concordância entre os testes, na amostra aleatória de pacientes, utilizou-se o coeficiente de kappa e o teste de McNemar. Aplicou-se o teste de Wilcoxon para se comparar os tempos na execução de cada teste, sendo considerados significativos quando p<0,05. RESULTADOS: 52 pacientes com FC (29M/23F; 1,5 a 18,2 anos) realizaram o teste do suor pelas duas técnicas, apresentando valores medianos de cloro e condutividade no suor de 114 e 122 mmol/L, respectivamente. A condutividade foi ? 95 mmol/L em todos os pacientes, conferindo ao teste 100% de sensibilidade (IC95%: 93,1 a 100%). Cinquenta pacientes sem FC (24M/26F; 0,5 a 12,5 anos) apresentaram valores medianos de cloro e condutividade no suor de 15,5 e 30 mmol/L, respectivamente. Em todos os casos a condutividade foi < 70 mmol/L, conferindo ao teste 100% de especificidade (IC95%: 92,9 a 100%). Foram então realizados 918 testes nos pacientes em investigação para FC, mas, em 180, as amostras foram inadequadas. Dos 738 testes realizados pelas duas técnicas, em 714 pacientes se afastou a FC, encontrando-se mediana de cloro de 11 mmol/L (variação: 3 a 137 mmol/L) e de condutividade de 25 mmol/L (variação: 14 a 138 mmol/L). Foram confirmados 24 pacientes com FC, encontrando-se uma mediana de cloro de 87 mmol/L (variação: 54 a 132 mmol/L) e de condutividade de 103 mmol/L (variação: 50 a 126 mmol/L). Pela curva ROC, com valores de condutividade > 90 mmol/L, obteve-se S= 83,3%, E= 99,7%, VPP= 90,9% e VPN= 99,4% para o diagnóstico de FC. Com valores de condutividade < 75 mmol/L praticamente se pôde excluir o diagnóstico de FC (VPN=99,7%; IC95%:99,0-100%). Houve excelente concordância entre o teste clássico e o simplificado, tanto pelo valor de kappa (0,934; IC95% 0,86 a 1,009), quanto pelo teste de McNemar (p=1,0000). O tempo despendido na execução dos testes foi significativamente menor com o teste simplificado (p<0,0001) e o custo do método simplificado foi discretamente inferior. CONCLUSÕES: o teste da condutividade do suor, seja em pacientes com diagnóstico previamente conhecido (com ou sem FC) ou quando realizado aleatoriamente, mostrou resultados superponíveis ao teste clássico e foi capaz de diferenciar pacientes com e sem FC. O teste simplificado apresentou alta sensibilidade e especificidade e houve excelente concordância entre os testes. O tempo de execução foi mais rápido e o custo inferior ao teste clássico. / INTRODUCTION: despite the identification of over 1500 CFTR (cystic fibrosis transmembrane conductance regulator) gene mutations, the sweat test is still the diagnostic test for cystic fibrosis (CF). The quantitative pilocarpine iontophoresis test (QPIT) is the gold-standard method for collection of sweat and chloride analyses, but is subjected to errors if not performed by qualified technicians. Although the technique using the macroduct system for sweat collection and the conductivity analysis is simpler and has good correlation with chloride levels in previous studies, it is still considered a screening test for CF. The best cut-off point of sweat conductivity to confirm or rule out CF must yet be established. OBJECTIVES: to compare the sweat chloride values obtained by the quantitative pilocarpine iontophoresis test (classic test) with sweat conductivity analysis obtained by the macroduct (simplified test) in patients with a confirmed CF diagnosis, in patients without CF and in a random sample of patients being investigated for CF. The cost and time spent to perform each test were also analysed in the initial phase of the study. METHODS: both techniques of sweat test were simultaneously performed initially in patients with CF, afterwards in patients in whom CF had been ruled out and finally in patients referred for a sweat test between February 2006 and October 2008. The cut-off values for sweat conductivity to exclude or diagnose CF were = 90 mmol/L and for the QPIT were sweat chloride ? 60 e > 60 mmol/L, respectively. Contingency tables were used in the initial phase of the study (cases with or without CF) for calculation of sensitivity (Se), specificity (Sp), positive (PPV) and negative predictive value (NPV) and Fisher\'s exact test was used to assess the association between the tests and the presence or absence of CF. ROC curve was used in the random sample of patients also for calculation of Se, Sp, PPV and NPV and also to calculate the area under the curve between both tests in both phases of the study to assess their accuracy. The respective 95% confidence intervals (95%CI) were also analysed. Kappa coefficient and McNemar tests were used for evaluation of agreement between the tests in the random sample of patients. Wilcoxon test was used to compare the time spent to perform each test, with the significant difference set at p < 0.05. RESULTS: in 52 CF patients (29M/23F, age range 1.5 to 18.2y) the median value of sweat Cl and conductivity were 114 and 122 mmol/L, respectively. All patients had sweat conductivity values above 95 mmol/L (100% sensitivity; 95%CI: 93.1 to 100%). In 50 patients without CF (24M/26F, age range 6m to 12.5y) the median value of sweat Cl and conductivity were 15.5 and 30 mmol/L, respectively. All patients had conductivity values bellow 70 mmol/L (100% specificity; 95%CI: 92.9 to 100%). Nine hundred and eighteen tests were then performed in patients being investigated for CF but 180 had inadequate samples. Of the 738 tests performed with both techniques in 714 CF was ruled out, with median values of sweat Cl of 11 mmol/L (range: 3 to 137 mmol/L) and of conductivity of 25 mmol/L (range: 14 to 138 mmol/L). Twenty four patients had a diagnosis of CF presenting a median sweat Cl of 87 mmol/L (range: 54 to 132 mmol/L) and a median conductivity value of 103 mmol/L (range: 50 to 126 mmol/L). The ROC curve showed that with a conductivity value > 90 mmol/L sensitivity of 83.3%, specificity of 99.7%, PPV of 90.9% and NPV of 99.4% was obtained to diagnose CF. The best conductivity cut-off value to exclude CF was < 75 mmol/L (NPV=99.7%; IC95%:99.0-100%). Good agreement were observed between the tests (kappa: 0.934; IC95% 0.86 a 1.009; McNemar test: p=1.0000). The time spent to perform the tests was significantly lower with the simplified test (p<0.0001) and the cost was slightly lower with the conductivity test. CONCLUSIONS: sweat conductivity performed in patients with a known CF or non-CF diagnosis or randomly applied in subjects referred for a sweat test showed similar results as the classic test and could differentiate patients with or without CF. Conductivity test had a high sensitivity and specificity and good agreement was observed between the techniques. The time spent to perform the tests was lower with the simplified test, as well as the cost.
|
656 |
Preparação e caracterização de compósitos SiO2/Nafion® e TiO2/Nafion® / Preparation and characterization of SiO2/Nafion® and TiO2/Nafion® Composites.Marcasso, Tatiani 10 June 2011 (has links)
O presente trabalho tem como objetivo principal a preparação e a caracterização de compósitos sílica/Nafion® e titânia/Nafion®, sendo o óxido a fase maioritária. A incorporação do Nafion® se deu durante o processo sol-gel. Foram testadas duas rotas sintéticas para a sílica, sendo uma delas catalisada por HNO3 e a outra por NH4OH, e uma rota, catalisada por HNO3, para a titânia. Posteriormente, as amostras foram calcinadas e analisadas por diversas técnicas. A DRX mostrou que as sílicas obtidas eram amorfas e que as amostras de titânia, por sua vez, apresentavam as fases cristalinas anatase e bruquita. A partir das análises de área superficial (BET) e tamanho de poros, verificou-se que um pH de hidrólise mais baixo leva a formação de sílica e compósitos com maiores áreas superficiais e distribuições unimodais de tamanho de poros (inferiores a 2 nm), e um pH mais elevado a uma distribuição mais larga. A incorporação do Nafion® leva a uma diminuição dos valores de área superficial. As amostras de titânia e seus compósitos apresentaram áreas superficiais mais baixas e distribuição de tamanho de poros semelhantes às obtidas para as amostras do grupo da sílica básica. As isotermas de adsorção de água mostraram que a sílica ácida e seus compósitos têm seus microporos saturados em aproximadamente 50% de UR (umidade relativa). Já nas amostras de sílica básica e seus compósitos, essa saturação parece ocorrer em 75% de UR, mas a partir de 84% de UR há um súbito aumento de adsorção. Todos os compósitos apresentaram menor capacidade de adsorver água com relação aos respectivos óxidos. Os resultados obtidos por Análise Térmica levam a crer que a sílica confere maior estabilidade térmica ao Nafion® ao passo que o TiO2 parece catalisar a decomposição do mesmo. As análises de Espectroscopia Vibracional no Infravermelho e no Raman, não apresentaram indícios de ligações químicas formais entre o Nafion® e as matrizes de sílica e titânia. As micrografias obtidas por MEV das amostras selecionadas revelaram morfologia semelhante para as amostras \"SiO2/Naf 15%\" mesmo após calcinação a 100 e 200°C e um aumento da porosidade nas amostras \"SiO2 b/Naf 5%\". Já nas amostras \"TiO2/Naf 15%\" notou-se a coalescência das partículas se refletindo numa menor rugosidade no material. A EIE mostrou que a incorporação do Nafion® nas matrizes de sílica trouxe significativo aumento de condutividade protônica para a sílica ácida e diminuição da mesma para a sílica básica. Os compósitos titânia/Nafion® analisados na forma de monolitos exibiram altos valores de condutividade protônica, principalmente em umidades relativas acima de 53%. / The main aim of this work is the preparation and characterization of silica/Nafion® and titania/Nafion® composites, with the oxides as the major phase. Nafion® was incorporated during the sol-gel process. Two synthetic routes were tested for silica: catalyzed by HNO3 and NH4OH, and an HNO3-catalyzed route was used for titania. Subsequently, the samples were calcined and analyzed by different techniques. XRD showed that the obtained silicas were amorphous and the samples of titania showed the anatase and brookite crystalline phases. From the analysis of surface area (BET) and pore size, it was found that at a lower hydrolysis pH both silica and its composites present larger surface areas and unimodal pore size distributions (less than 2 nm). At higher pH, a wider pore size distribution is observed. The incorporation of Nafion® leads to a decrease in surface area in all cases. Titania and its composites showed lower surface area and pore size distribution similar to those obtained for basic silica samples. The water adsorption isotherms showed that the acid-catalyzed silica and its composites have their micropores saturated at approximately 50% RH. In the basic-catalyzed silica samples and their composites, the saturation seems to occur at 75% RH, but above 84% RH a sudden increase in adsorption occurs. All composites exhibited lower water adsorption capacities when compared to the respective pure oxides. The Thermal Analysis results suggest that the silica thermally stabilizes the Nafion® while titania seems to catalyze the decomposition of it. Vibrational spectroscopy (Infrared and Raman) spectra showed no evidence of formal chemical bonds between Nafion,® and silica or titania. The SEM micrographs of selected samples reveal similar morphology for the samples \"SiO2/Naf 15%\" even after calcination at 100 and 200 °C, and a porosity increase in samples \"SiO2 b/Naf 5%\". In the \"TiO2/Naf 15%\" samples, particle coalescence was observed, which is reflected in a lower roughness in the material. According to EIS results the incorporation of Nafion® into the silica matrices caused significant increase in proton conductivity for acid silica and its reduction for the basic silica. The titania/Nafion® composites that were analyzed as monoliths exhibited high proton conductivity, mainly in relative humidities above 53%.
|
657 |
Determinação de propriedades termofísicas do pão tipo francês durante o processo de assamento. / Determination of thermophysical properties during french bread baking process.Queiroz, Gilmar Michel 08 May 2001 (has links)
No presente trabalho, as propriedades termofísicas do pão francês durante o assamento foram determinadas. Os pães foram feitos na Padaria Piloto do Laboratório de Engenharia de Alimentos do Departamento de Engenharia Química da Escola Politécnica da Universidade de São Paulo, com formulação semelhante aos pães comercializados. Durante o assamento, mudanças profundas ocorreram nos pães como diminuição do conteúdo de água de 44,1 para 30,8 % e aumento do volume de 382 para 420 cm3. Devido ao aumento do volume e diminuição da massa, a densidade aparente do pão francês variou de 0,231 g/cm3 para o pão sem assamento a 0,324 g/cm3 para o pão com 14 minutos de assamento. A difusividade térmica efetiva do pão francês foi determinada a partir das curvas de penetração de calor considerando o pão como um cilindro bidimensional. As curvas foram registradas a uma taxa de 30 aquisições/minuto durante o assamento dos pães em um forno turbo com dispositivo de vaporização. O valor médio da difusividade térmica encontrada para o pão francês durante o assamento foi de 4,1 ´ 10-7 m2/s. A condutividade térmica efetiva do pão francês foi determinada pelo método da sonda linear de aquecimento em diferentes tempos de assamento. A sonda linear utilizada nos ensaios foi dimensionada e construída no laboratório para o pão francês. A condutividade térmica efetiva do pão francês variou de 0,283 W/m K para o pão sem assamento a 0,136 W/m K para o pão com 14 minutos de assamento. Os resultados foram comparados com dados existentes na literatura. Um modelo empírico foi proposto para correlacionar a condutividade térmica do pão francês com o seu conteúdo de água e sua densidade aparente. / In this work, thermophysical properties of the french bread during baking were determined. Breads were produced at the Pilot Bakery of the Food Engineering Laboratory of the Chemical Engineering Department of Escola Politécnica of São Paulo University, with a formulation similar to breads purchased at the market. During baking, deep changes ocurred in the breads such as a water content decrease from 44,1 to 30,8 % and an increase of volume from 382 to 420 cm3. Due to the increase of volume and mass decrease, the bulk density of french bread changed from 0,324 g/cm3 for the dough to 0,231 g/cm3 for the bread with 14 minutes of baking. Effective thermal diffusivity of french bread was determined through heat penetration curves in a bidimensional cylinder. Temperature history was registred at a rate of 30 samples/minute during bread baking in a turbo oven with a vaporization device. The average value of thermal diffusivity to the french bread during baking was 4,1´10-7 m2/s. The effective thermal conductivity of the french bread was determined by the line heat source method in different times of baking. The thermal conductivity probe used was designed and built at the laboratory for french bread. The effective thermal conductitivy of the french bread changed from 0,283 W/m K for the dough without baking to 0,136 W/m K for the bread with 14 minutes of baking. Results were compared with literature data. An empiric model was proposed to correlate the french bread thermal conductivity with its water content and bulk density.
|
658 |
Caracterização da condutividade térmica, viscosidade dinâmica e ângulo de contato para nanofluidos baseados em partículas de alumina-gama em água / Characterization of the thermal conductivity, dynamic viscosity and contact angle of nanofluids based on gama-alumina nanoparticles in waterMotta, Franciane de Campos 26 April 2012 (has links)
Este trabalho trata da caracterização de propriedades termodinâmicas e de transporte de nanofluidos baseados em nanopartículas de alumina em água para diferentes concentrações. Suspensões estáveis foram elaboradas por meio de um agitador ultrassônico. As seguintes propriedades foram analisadas: i) condutividade térmica com o método da sonda-linear; ii) viscosidade dinâmica através do reômetro do tipo cone e placa e iii) ângulo de contato com base em registros fotográficos de gotas em uma superfície plana e o tratamento de imagem através de um programa elaborado em LabVIEW. Procedimentos foram utilizados visando validar os métodos experimentais adotados, entre eles a comparação com resultados para fluidos puros. Além do estudo experimental, foi realizada uma análise crítica da literatura sobre condutividade térmica e viscosidade dinâmica de nanofluidos. Com base nesta análise, os resultados experimentais foram comparados a dados empíricos da literatura e métodos de previsão de propriedades desenvolvidos para nanofluidos e para suspensões de particulado sólido em líquido. De uma maneira geral, os resultados levantados neste estudo para condutividade térmica e viscosidade dinâmica de nanofluidos foram significativamente superiores a maioria dos dados experimentais da literatura e aos resultados proporcionados pelos métodos de previsão. Entretanto, para nanofluidos com composições distintas de nanopartículas de alumina em água, comportamentos similares ao do presente estudo também são observados na literatura. No caso do ângulo de contato, verificou-se seu decréscimo com o incremento da concentração de nanopartículas. Tal resultado coincide com a bibliografia consultada, segundo a qual a molhabilidade do nanofluido se eleva com o incremento da concentração de nanopartículas. / The present study concerns the characterization of thermodynamic and transport properties of nanofluids based on alumina nanoparticles in deionized water. Stable suspensions were obtained using an ultrasonic homogenizer (Sonicator). The following properties were measured: i) thermal conductivity using the linear probe method, ii) dynamic viscosity through a cone-plate rheometer iii) contact angle, based on photographic of nanofluid drops on a flat surface and image processing through a program based on LabVIEW. The methods and experimental procedures were validated by performing measurements properties of pure fluids with well known characteristics. Besides the experimental study, it was performed a comprehensive literature review on thermal conductivity and dynamic viscosity of nanofluids. Experimental results were compared against the data from the literature and the respective predictive methods developed for suspensions of nanofluids and micro solid particles in liquid. Generally speaking, the nanofluid thermal conductivity and dynamic viscosity measured in the present study were higher than the empirical values from the literature and the values given by predictive methods. However, it should be highlighted that although for different compositions of nanofluids behaviors similar to the one observed in this study are also reported in the literature. In case of contact angle, it was found that its value decreases with increasing the nanoparticle volumetric concentration. Such results is coincident with literature reports according to which the nanofluid wettability, given in terms of the contact angle, increases with increasing the nanoparticle concentration.
|
659 |
Desenvolvimento e ensaios de um sistema de mensuração de condutividade elétrica do solo. / Development and field evaluation of a soil electrical conductivity measuring system.Pincelli, André Luis Sacomano 03 December 2004 (has links)
A correlação entre as medidas de condutividade elétrica e propriedades físico-químicas do solo é uma das linhas de estudo que vem sendo exploradas onde os conceitos de agricultura de precisão estão mais avançados. Este estudo teve como objetivo avaliar a eficiência do monitoramento da condutividade elétrica do solo a partir do desenvolvimento de dois sistemas. O primeiro, denominado de Resistência Elétrica do Solo (RES), consiste em definir a condutividade elétrica de um material através de uma amostra de dimensões conhecidas, para medir a sua resistência elétrica utilizando dois eletrodos. O segundo, denominado de Duas Pontas (DP), consiste em definir a condutividade elétrica de um material aplicando uma corrente elétrica em uma amostra para medir a alteração no potencial elétrico, gerado pelo meio em que a corrente elétrica transitou, utilizando dois eletrodos dispostos linearmente. Para a avaliação dos resultados obtidos pelos sistemas desenvolvidos foi utilizado como referência um sistema comercial de origem norte americana e algumas propriedades do solo. Os equipamentos de condutividade elétrica do solo foram aplicados em duas áreas pertencentes à Escola Superior de Agricultura "Luiz de Queiroz" e em época distintas. Na Área 1, com 4,97 ha, o levantamento dos dados foi feito na primeira quinzena de Agosto de 2003 e na Área 2, com 1,3 ha, o levantamento dos dados foi feito na segunda quinzena de Dezembro de 2003. Após a aquisição dos dados experimentais foram feitas análises estatísticas descritivas e exploratórias, análises geoestatísticas, construção de mapas de superfície, análises de correlação e regressão linear múltipla a fim de avaliar os sistemas. De acordo com a metodologia desenvolvida e análises de funcionamento dos equipamentos, foi possível verificar que os sistemas construídos para a coleta, transformação e armazenagem dos dados foram eficientes no levantamento dos pontos amostrais. No entanto os sistemas de condutividade elétrica do solo não apresentaram a eficiência desejada no monitoramento das propriedades do solo em ambas as áreas experimentais. Quando os sistemas desenvolvidos foram comparados ao sistema comercial, também foi possível observar que não houve correlação no monitoramento, o que sugere a necessidade da continuidade e aprofundamento no desenvolvimento desses sistemas. / The correlation between electrical conductivity and physical-chemical properties of the soil is one of the research areas that have been explored where precision agriculture concepts are more advanced. This study had the objective of evaluating the soil electrical conductivity mapping efficiency of different measuring systems. The first one, known as Electrical Resistance of the Soil consists in defining the electrical conductivity of any given material using a sample of known dimensions, to measure its electrical resistance using two electrodes. The second one, the Two Edges method, consists in defining the electrical conductivity of a material applying an electric current in a sample to measure any change on the electric potential, generated by the environment in which the electric current transited through, using two linearly displaced electrodes. To evaluate the results obtained by the developed systems some soil properties and a commercial soil electrical conductivity measuring system where used as guidelines. The soil electrical conductivity equipments mapped two fields, at the Escola Superior de Agricultura "Luiz de Queiroz". In Field 1 (4,97 ha) the data collecting process took place in the first fortnight of august 2003, and, in Field 2 (1,3 ha), the sampling process took place in the second fortnight of December 2003. After the acquisition of the experimental data, descriptive and exploratory statistical and geostatistical analysis were made, electrical conductivity surface maps were obtained and correlation and multiple linear regression analysis, in order to evaluate both systems, were made. In accordance to the developed methodology and analysis of the equipment, it was possible to check that the systems developed to acquire, transform and store the data were efficient in mapping the sampling points. However, the soil electrical conductivity systems did not show the desired efficiency in mapping the soil properties in both experimental fields. When the developed systems were compared to a commercial one it was also possible to observe that there was no correlation in the measurements, which suggests the necessity of new developments on these systems.
|
660 |
Estudos de condutividade elétrica em compostos iônicos do tipo ABF2 e A2B\'F6. / Study of electrical conductivity of ABF2 and A2B\'F6 ionic compounds.Gallo, Nelson Jose Heraldo 28 January 1980 (has links)
Neste trabalho determinou-se os valores de condutividade elétrica em diversos compostos iônicos do tipo ABF6 (A= Li, Na, K, Ag; B= P, Sb, Ti), utilizando-se a técnica de corrente contínua. Todos estes compostos possuem valores de condutividade elétrica maiores que os halogenetos alcalinos, mas nenhum deles podem ser classificados como condutores superiônicos. O maior valor obtido pertence ao sal LiPF6 que tem con¬dutividade elétrica de 1,03 x 107 Ohm-1 cm-1 na temperatura de 150°C valor este várias ordens de grandeza maior que KCl na mesma temperatura (3,26 x 10-12 Ohm-1cm1). Um breve apanhado sobre os condutores superiônicos e fornecido, juntamente com possíveis aplicações destes compostos em baterias de estado sólido. / The D.C. electrical conductivity technique has been used to determine the electrical conductivity values of several ionic compounds of the ABF6 family (A=Li, Na, K, Ag; B = P, Sb, Ti). Al1 these compounds have electrical conductivity values higher than those of alkali halides, however none of then can be classified as superionic conductors. Of the several ionic compounds studied, it was found that LiPF6 has the greatest electrical conductivity value at 150°C (1,03 x 107 Ohm-1 cm-1). This values is several ordes of magnitude higher than those of KCl at the same temperature (3,26 x 10-12 Ohm-1cm1). A short review of superionic conductors is introduced and some possible uses of these compounds in solid state batteries are discusses.
|
Page generated in 0.1148 seconds