• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 752
  • 34
  • 12
  • 7
  • 7
  • 7
  • 7
  • 5
  • 2
  • 1
  • 1
  • Tagged with
  • 809
  • 406
  • 221
  • 198
  • 194
  • 187
  • 139
  • 109
  • 108
  • 107
  • 107
  • 104
  • 97
  • 89
  • 83
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Resposta magnética de supercondutores estruturados: dependência com a granulometria

Trípodi, Alonso Campoi 26 February 2010 (has links)
Made available in DSpace on 2016-06-02T20:16:45Z (GMT). No. of bitstreams: 1 2809.pdf: 1662385 bytes, checksum: 6fb1703bc2085627924b6689877b0ad9 (MD5) Previous issue date: 2010-02-26 / Universidade Federal de Sao Carlos / The maximum critical current that a granular superconductor is able to transport is, in general, limited by the critical current of the weak-links (WLs), which connect neighbor grains. For samples whose intergranular critical current distributions are sufficiently narrow, the temperature dependence of the AC-susceptibility, ( ) '( ) ''( ) ACχ T=χT+iχ T, exhibits a characteristic structure, with two plateaus peaks in χ´ and two peaks in χ´´. The occurrence of an intergranular peak evidences a good control of the WL distribution concerning current transport capability, which, in general, depends on parameters that can be controlled during production of the granular samples. In order to study magnetic flux trapping in superconducting samples, one has to understand the weak-link behavior. The screening and trapping capabilities of a superconducting sample are reflected by the hysteresis loops which, properly treated, reveal the sample maximum capability to transport currents. In this work we have used niobium powder to study the magnetic response of the intergranular regions of compressed pellets; we have managed to understand the role of each of three parameters employed while preparing the pellets: pressure, grain size and its dispersion. We have studied the magnetic response (magnetization and AC susceptibility) dependence on such , controllable parameters. Dissertação de Mestrado Alonso Campoi Trípodi We noticed that samples prepared with higher pressures have larger capability to trap magnetic flux in the intergranular region and stronger WLs. On the other hand, samples with larger particles have WLs with higher critical temperatures, that is, pellets fabricated from larger particles exhibit more robust superconductivity. We have observed the Paramagnetic Meissner Effect, in the form of reentrant curves of Magnetization as a function of Temperature. Comparing pellets with different grain sizes, flux trapping was most efficient for samples with large particles and lower size dispersion. We verified also the metastable character of states prepared in such a way that flux was retained, comparing magnetization measurements before and after application of an AC field, which causes partial release of magnetic flux from intergranular regions, an effect similar to the so-called Vortex Shaking. We also conducted experiments as a function of the applied magnetic field the hysteresis loops aiming at obtaining the magnetic field dependence of the critical current, employing a critical state model for this task. We verified that, for lower temperatures, the critical current density is higher for pellets with larger particles and narrow size dispersion. In summing up, our results clearly indicate that, for a certain granulometry, larger compacting pressures lead to more diamagnetic responses, as well as to WLs with narrower superconducting transitions which turn off at larger temperatures. On the other hand, for a certain compacting pressure in pellets with narrow size dispersions, larger particles lead to stronger WLs. / A máxima corrente crítica que pode ser transportada através de um supercondutor granular é, em geral, limitada pela corrente crítica dos elos fracos (EFRs) que acoplam grãos vizinhos. Para amostras cuja distribuição de correntes críticas intergranulares é suficientemente estreita, a dependência da suscetibilidade-AC com a temperatura, ( ) '( ) ''( ) ACχ T=χT+iχ T, exibe uma estrutura característica, com dois patamares em χ ' e dois picos em χ '' . A ocorrência de um pico intergranular estreito evidencia um bom controle da distribuição dos EFRs no que se refere à sua capacidade de transporte, o quê, em geral, depende de parâmetros que podem ser controlados durante a produção de amostras granulares. Para estudar a retenção de fluxo magnético em amostras supercondutoras é preciso entender o comportamento dos elos fracos. A capacidade de blindagem e aprisionamento de uma amostra supercondutora reflete-se diretamente em seu ciclo de histerese que, devidamente tratado, revela a máxima capacidade de transporte de corrente da amostra. Neste trabalho de mestrado, utilizamos pó de nióbio para estudar a resposta magnética das regiões intergranulares de pastilhas formadas a partir da compactação do pó, tratando de compreender o papel de três parâmetros empregados na preparação da pastilha: a pressão de compactação do pó, o tamanho dos grãos e a sua dispersão. Estudamos a dependência da resposta magnética (magnetização e suscetibilidade AC) com tais parâmetros controláveis. Dissertação de Mestrado Alonso Campoi Trípodi Constatamos que amostras preparadas com maiores pressões têm maior capacidade de aprisionamento de fluxo magnético na região intergranular e EFRs mais fortes. Por outro lado, amostras com partículas maiores têm EFRs com temperaturas críticas mais altas, ou seja, pastilhas fabricadas com partículas maiores exibem uma supercondutividade mais robusta. Observamos o Efeito Meissner Paramagnético, na forma de reentrâncias em curvas de Magnetização em função da Temperatura. Comparando pastilhas com diferentes tamanhos de grãos, o ancoramento dos fluxo foi mais eficaz em amostras com partículas grandes e pequena dispersão de tamanho. Verificamos também o caráter metaestável de estados preparados de modo que houvesse fluxo aprisionado, comparando medidas de magnetização antes e depois da aplicação de um campo AC, que causa desprendimento parcial do fluxo magnético aprisionado em regiões intergranulares, efeito similar ao chamado Vortex Shaking. Realizamos também experimentos em função do campo magnético aplicado - os chamados laços de histerese - com vistas à obtenção da dependência da corrente crítica com o campo magnético aplicado, empregando para isso um modelo de estado crítico. Verificamos que para temperaturas mais baixas a densidade de corrente crítica é maior para pastilhas com partículas maiores e pequena dispersão de tamanho. Em resumo, nossos resultados indicam claramente que, para uma mesma granulometria, maiores pressões de compactação propiciam respostas mais diamagnéticas, bem como EFRs com transições mais estreitas e que desligam em temperaturas mais altas. Por outro lado, para uma mesma pressão de compactação em pastilhas com pequena dispersão de tamanho, partículas maiores levam à criação de EFRs mais fortes.
132

O estudo do limite de transporte interfilamentar de supercorrentes em amostras supercondutoras de BSCCO.

Deimling, Cesar Vanderlei 15 March 2006 (has links)
Made available in DSpace on 2016-06-02T20:16:55Z (GMT). No. of bitstreams: 1 930.pdf: 1326398 bytes, checksum: 3d8124516e447b70160e95eafd033b19 (MD5) Previous issue date: 2006-03-15 / Universidade Federal de Sao Carlos / In this work, we have studied the behavior of the line H*(T) in filamentary samples of BSCCO, which were grown by the LFZ technique, Laser Floating Zone. Previously studied in other specimens prepared by specific routes for exemple, samples of Mgdeficient MgB2; YBCO prepared by the Sol-Gel technique; or polycrystalline samples of Nb the H*(T) frontier defines the region in the magnetic fase diagram above which the intergranular critical current density vanishes. The H*(T) line is an extrinsic feature, dependent on the preparation and subsequent heat treatment of the samples, observed only in specimens having a narrow intergranular critical current distribution, which can be obtained controlling properties such as granularity. Measurements of ac-susceptibility as a function of temperature has been performed, for different values of the magnetic excitation field, from which a point was determined, T*, above which the ac-susceptibility is independent of the intensity of the magnetic excitation field. This means that, above T*, only the intrafilamentary regions are able to transport supercurrents. Relating the magnetic measurements with results of transport measurements four terminals and flux transformer we have found a complete similarity between T* and the offset critical temperature, Tc off. We have also verified that T* depends on the field H, so that the magnetic phase diagram includes an extrinsic frontier H*(T), confirming the original expectation that the intergranular space surrounding the grains of a system with controlled granularity, may constitute an efficient set of pinning centers for magnetic flux, what occurs, in fact, in the region to which H*(T) is an upper bound, where the intergranular critical currents are nonzero. It is quite impressive that different samples present practically coincident H*(T) frontiers, what reinforces the prediction that the studied line has a universal character, as long as the sample fulfills the criterion of exhibiting a narrow intergranular critical current distribution. / Neste trabalho, estudamos o comportamento da linha H*(T) em amostras filamentares de BSCCO, crescidas pela técnica LFZ, Laser Floating Zone. Estudada previamente em outros espécimes preparados por rotas específicas - por exemplo, amostras de MgB2 deficientes em Mg; de YBCO preparadas pela técnica Sol-Gel; ou amostras policristalinas de Nb - a fronteira H*(T) delimita a região do diagrama de fases magnéticas acima da qual a densidade de corrente crítica intergranular torna-se nula. A linha H*(T) é uma característica extrínseca, dependente da preparação e do posterior tratamento térmico das amostras, sendo observada apenas em espécimes que apresentam uma distribuição estreita de correntes críticas intergranulares, que pode ser obtida a partir do controle de propriedades tais como a granularidade. Medidas de suscetibilidade-ac em função da temperatura foram realizadas, para diferentes valores do campo magnético de excitação, encontrando-se um ponto, T*, acima do qual a suscetibilidade-ac independe da intensidade do campo magnético de excitação. Isto significa que acima de T* apenas as regiões intrafilamentares são capazes de transportar supercorrentes. Relacionando as medidas magnéticas com os resultados das medidas de transporte elétrico usando duas técnicas diferentes quatro terminais e transformador de fluxo constatamos uma total similaridade entre T* e a temperatura crítica de offset, Tc off. Verificamos ainda que T* depende do campo H, de modo que o diagrama de fases HxT inclui a fronteira extrínseca H*(T), característica da amostra. A inclusão das linhas Hirr(T) e Hc2(T), que são características do material, no mesmo diagrama HxT, permite situar a linha extrínseca no cenário composto pelas fronteiras intrínsecas do material. Medidas de relaxação temporal da resistividade e da magnetização evidenciam que os vórtices penetrados têm menor mobilidade na região que fica abaixo da fronteira H*(T), confirmando a expectativa inicial de que o espaço intergranular que margeia os grãos de um sistema com granularidade controlada, pode constituir-se em um arranjo para a ancoragem eficiente de fluxo magnético, o que ocorre de fato na região delimitada superiormente por H*(T), na qual as correntes críticas intergranulares são diferentes de zero. É notável que amostras diferentes tenham apresentado fronteiras H*(T) praticamente coincidentes, o que reforça a previsão de que a linha estudada tenha caráter universal, desde que a amostra satisfaça o critério de exibir uma distribuição estreita de correntes críticas intergranulares.
133

Tomografia por biosusceptometria de corrente alternada

Fonseca Filho, Paulo Roberto da [UNESP] 03 February 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:14Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-03Bitstream added on 2015-05-14T16:59:09Z : No. of bitstreams: 1 000822024_20160203.pdf: 74282 bytes, checksum: 81fcaba4dabd99298046b62189ca92be (MD5) Bitstreams deleted on 2016-02-03T15:35:12Z: 000822024_20160203.pdf,. Added 1 bitstream(s) on 2016-02-03T15:35:53Z : No. of bitstreams: 1 000822024.pdf: 798249 bytes, checksum: cf24aa6eedaa8b219d13e0e5cf032c2e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A busca por novos métodos de imagens, principalmente os livres de radiação ionizante, são importantes tanto pelas instrumentações, quanto para as finalidades. A Biosusceptometria de |Corrente Alternada (BAC) possui versatilidade, sensibilidade, baixo custo e têm sido amplamente utilizada na aquisição de imagens para estudos nas áreas de gastrenterologia, fisiologia, farmacologia e farmácia. O objetivo deste trabalho foi caracterizar sistemas de BAC na produção de imagens tomográficas de objetos simuladores, propondo a viabilidade da técnica de tBAC - tomografia por biosusceptometria de Corrente Alternada. Para tanto, os gradiômetros de dois sistemas BAC com 13 e 37 canais com compensação de campo de excitação foram avaliados quanto à sua sensibilidade e resolução para produzir imagens de simuladores de barras e cilíndri-cos. Foi possível reconstruir imagens de todos os objetos com boa correlação entre a imagem e as caracte-rísticas físicas dos objetos (forma e concentração de traçador magnético). As melhores imagens foram pro-duzidas quando foi utilizada aquisição multicanal no sistema de BAC com 37 sensores utilizando compen-sação de campo, os quais possuem menores diâmetros. Dessa forma verificou-se que os sistemas BAC podem ser empregados com sucesso para produzir imagens tomográficas de objetos com pequena quanti-dade de traçador magnético, o que viabiliza sua aplicação futura em pequenos animais, farmacotecnia ou ainda ensaios não destrutivos / The development of new imaging methods, especially those that are free of ionizing radiation, constitute a very important topic because for both instrumentation development and its applications. The Alternating Current Biosusceptometry (ACB) has versatility, sensibility and low cost and has been widely used on image acquisition on gastroenterology, physiology, pharmaceutics and pharmacology researches. The aim of this project was to characterize ACB systems to produce tomographic images of simulating objects ver-ifying the technical viability of the AC Biosusceptometry Tomography (ACBT). The capability of ACB gradiometers of 13 and 37 channel systems with compensation field to reconstruct images of bars and cy-lindrical phantoms were evaluated, especially sensibility and resolution. It was possible to reconstruct im-ages from all objects with good correlation between the image and the phantom (geometry and magnetic tracer concentration). Better results were observed while using multichannel acquisition on 37-channel sys-tem with active excitation magnetic field. Therefore we verified that ACB systems can be successfully used on tomographic imaging of objects with small quantities of magnetic tracer, which is viable to future ap-plication on small animal physiology, pharmaceutics or non-destructive evaluation research
134

Avaliação experimental de um sistema não linear para extração de energia através de vibrações utilizando material piezelétrico

Carvalho, Felipe Carmo [UNESP] 30 May 2014 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:53Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-05-30Bitstream added on 2014-12-02T11:20:57Z : No. of bitstreams: 1 000797355.pdf: 2534975 bytes, checksum: 3639cd14e2f11ddb6a8be1fb6e663b57 (MD5) / Afim de suprir a necessidade por fontes alternativas de energia para a alimentação de sistemas microeletrônicos autônomos, os estudos têm se voltado para a utilização de materiais piezelétricos para a transformação de energia derivadas de vibrações mecânicas em energia elétrica. Como a potência fornecida pelas vigas com materiais piezelétricos é pequena e, geralmente, insuficientes para alimentar dispositivos eletrônico de forma autônoma, técnicas de extração, conversão e armazenamento de energia são utilizadas para otimizar a energia final acumulada. Neste sentido, este trabalho tem por objetivo a otimização de um sistema extrator de energia através de vibrações utilizando material piezelétrico, maximizando a potência extraída e melhorando o rendimento do sistema. Para isto, foram analisadas condições de linearidade e não linearidade no sistema e os respectivos circuitos conversores foram projetados e testados experimentalmente. A melhor configuração eletromecânica para extração de energia, o sistema será utilizada para alimentar um sistema autônomo. Foram projetados dois sistemas de monitoramentos com consumo de energia diferentes, para avaliar as limitações e potencialidades da proposta de sistema para extração de fontes alternativas de energia elétrica / In order to meet the need for alternative energy sources to power autonomous microelectronic systems, studies have focused on the use of piezoelectric materials to transform energy derived from mechanical vibrations into electrical energy. Once the power delivered by the cantilever beams with piezoelectric materials are insufficient to power electronic devices autonomously, extraction techniques, conversion and energy storage was used to optimize the final accumulated energy. Considering that, this work aims at the optimization of an extractor system energy through vibrations using piezoelectric material, maximizing the power extracted and improving system performance. To this end, conditions of linearity and non-linearity in the mechanical system, as well as designed and tested converter circuits were analyzed. The best setup for electromechanical energy extraction, was used to feed an autonomous system. Two different power consumption-monitoring systems were designed to assess the limitation and potentialities of the proposed alternative for energy harvesting
135

Estimulação transcraniana por corrente contínua : efeitos sobre a memória operacional de idosos

Alecastro, Aline Simões de 25 November 2016 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2016. / Submitted by Camila Duarte (camiladias@bce.unb.br) on 2017-01-12T13:08:58Z No. of bitstreams: 1 2016_AlineSimõesdeAlencastro.pdf: 2285135 bytes, checksum: e1601361410b03fbc0c03cf23f6aa10e (MD5) / Approved for entry into archive by Ruthléa Nascimento(ruthleanascimento@bce.unb.br) on 2017-03-09T14:35:07Z (GMT) No. of bitstreams: 1 2016_AlineSimõesdeAlencastro.pdf: 2285135 bytes, checksum: e1601361410b03fbc0c03cf23f6aa10e (MD5) / Made available in DSpace on 2017-03-09T14:35:07Z (GMT). No. of bitstreams: 1 2016_AlineSimõesdeAlencastro.pdf: 2285135 bytes, checksum: e1601361410b03fbc0c03cf23f6aa10e (MD5) / O transtorno cognitivo leve e as demências têm se tornado problemas médicos cada vez mais frequentes, acompanhando o aumento da longevidade da população. Entretanto, terapias eficazes para essas condições ainda não estão disponíveis. Estudos recentes têm demonstrado que a estimulação transcraniana por corrente contínua (ETCC) é capaz de potencializar o desempenho de indivíduos jovens normais em testes de memória de trabalho. Alterações da memória de trabalho são frequentes em indivíduos idosos, mas poucos estudos têm verificado possíveis efeitos benéficos da ETCC nesse grupo etário. A memória de trabalho envolve diversas estruturas neurais em ambos os hemisférios cerebrais, mas o córtex pré-frontal dorsolateral (CPFDL) parece ter um papel fundamental. O presente trabalho teve como objetivo verificar possíveis efeitos da ETCC aplicada sobre o CPFDL esquerdo de indivíduos idosos sobre dois testes de memória operacional: o teste de sequências de letras e números e o teste dos cubos de Corsi (TCC). Dezenove idosos, com idades de 65 a 79 anos, participaram do estudo. Cada voluntário foi submetido a duas sessões de ETCC, uma real e outra fictícia, com a realização dos testes de memória de trabalho durante a estimulação cerebral. A ordem de realização das sessões real e fictícia foi randomizada entre os voluntários, sendo que 10 deles foram submetidos primeiramente à estimulação fictícia. Foi observado um declínio significativo (p< 0,01) da performance no TCC durante a estimulação real do CPFDL esquerdo. Também ocorreu piora na execução do teste de sequência de letras e números, porém sem alcançar significância estatística. Este resultado permite concluir que: (1) diferentemente do que foi descrito na literatura para indivíduos jovens, a ETCC anódica do CPFDL esquerdo produz, em idosos, uma disrupção dos processos neurais envolvidos na memória de trabalho; (2) o hemisfério cerebral esquerdo também desempenha um papel importante na memória de trabalho visuoespacial, avaliada com o TCC. / Mild cognitive impairment and dementias have become increasingly important medical issues, as populations get older. However, there is still a lack of effective treatments for these conditions. Recent studies have demonstrated that transcranial direct current stimulation (tDCS) is able to enhance the performance of young healthy subjects in tests of working memory. Working memory impairment is frequent in older individuals, but few studies have addressed possible beneficial effects of tDCS in this age group. Working memory engages several structures in both cerebral hemispheres, but the dorsolateral prefrontal cortex (DLPFC) seems to play a fundamental role. This study aimed at verifying possible effects of tDCS applied to the left DLPFC of older subjects upon two working memory tests: letter-number sequencing (LNS) and the Corsi block test (CBT).Nineteen older subjects, aged 65 to 79, took part in the study. Each volunteer underwent two tDCS sessions, one real and the other sham, during the performance of the neuropsychological tests. The order of the real and sham sessions was counterbalanced across subjects, and 10 subjects had the sham session first. There was a significant (p<0.01) decline in performance of the CBT during real anodal tDCS of the left DLPFC. A decline in performance was also present for the LNS, but without statistical significance. These results show that: 1. in contrast to the improvement reported for young healthy subjects, anodal tDCS of the left DLPFC produces, in older subjects, a disruption of neural processes involved in working memory; 2. the left cerebral hemisphere also seems to play an important role in visuo-spatial working memory, as tested by the CBT.
136

Estudo prospectivo e comparativo do uso de lock terapia profilática com gentamicina/cefazolina versus taurolidina/citrato em cateteres tunelizados para hemodiálise / Prospective and comparative study of prophylactic lock therapy using gentamicin / cefazolin versus taurolidine / citrate in tunneled central catheters for hemodialysis

Bueloni, Tricya Nunes Vieira 23 February 2018 (has links)
Submitted by TRÍCYA NUNES VIEIRA BUELONI null (tbueloni@gmail.com) on 2018-03-28T00:50:38Z No. of bitstreams: 1 Tese doutorado versão repositório.pdf: 1144023 bytes, checksum: 6ce61134d85d148bb9fe48f97b75c860 (MD5) / Approved for entry into archive by ROSANGELA APARECIDA LOBO null (rosangelalobo@btu.unesp.br) on 2018-03-29T13:54:10Z (GMT) No. of bitstreams: 1 bueloni_tnv_dr_bot.pdf: 1144023 bytes, checksum: 6ce61134d85d148bb9fe48f97b75c860 (MD5) / Made available in DSpace on 2018-03-29T13:54:11Z (GMT). No. of bitstreams: 1 bueloni_tnv_dr_bot.pdf: 1144023 bytes, checksum: 6ce61134d85d148bb9fe48f97b75c860 (MD5) Previous issue date: 2018-02-23 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Introdução: Hemodiálise (HD) é a modalidade de terapia renal substitutiva mais amplamente utilizada no mundo e o uso de cateteres venosos centrais (CVC) tem aumentado como forma primária de acesso vascular para HD. Apesar da vantagem de obtenção imediata de acesso, a forte associação do CVC com infecções de corrente sanguínea (ICS), elevada morbidade e mortalidade vem direcionando inúmeros estudos com a finalidade de prevenir infecções relacionadas ao CVC na população em HD, destacando-se estudos com uso de lock terapia profilática. Diversas substâncias foram testadas em lock terapia profilática, porém a comparação entre drogas com ação antimicrobiana e antibióticos foi pouco estudada, sem determinação da melhor solução para profilaxia. Os objetivos deste trabalho foram comparar a eficácia do uso de antibioticoterapia em lock gentamicina + cefazolina versus o uso de taurolidina + citrato em relação às taxas ICS relacionadas a cateteres tunelizados e às complicações relacionadas à lock terapia (resistência bacteriana e oclusão trombótica). Métodos: Estudo Quasi-experimental, prospectivo e comparativo em dois centros de diálise, incluindo CVC tunelizados para HD com inserção no momento do estudo. Foram implantados 145 CVC em 127 pacientes, seguidos durante 15 meses consecutivos. Os pacientes foram alocados em cada grupo de acordo com o centro de hemodiálise pertencente: Grupo 1: 65 pacientes (77 CVC) em uso de antibiótico em lock (gentamicina 7,2 mg/ml + cefazolina 12 mg/ml + heparina 3500UI/ml). Grupo 2: 62 pacientes (68 CVC) em uso de taurolidina + citrato 4% + heparina 500UI/ml (taurolockTM –Hep 500). A densidade de incidência de infecção foi calculada pelo número de eventos por 1000 cateteres-dia. Curvas de sobrevida livre de ICS, IOS e complicação mecânica foram realizadas pelo método de Kaplan Meyer, bem como análise de regressão de Cox, incluindo as variáveis: grupo, sítio de cateter, tempo em hemodiálise até o implante, comorbidades, idade e doença de base. Resultados: Os dois grupos foram semelhantes quanto ao sexo, idade, doença de base, comorbidades e tempo em HD. Não houve diferença entre os grupos quanto às prevalências de IOS e de ICS e densidade de incidência de ICS (G1=0,79 e x G2=1,10 eventos por 1000 cateteres-dia, p=0,18) e de IOS (G1=2,45 x G2=1,83 eventos por 1000 cateteres-dia, p=0,37). Os grupos também foram semelhantes quanto ao tempo livre de infecção e retirada do CVC. Porém, os grupos diferiram quanto aos agentes etiológicos nas IOS, sendo os Gram positivos oxacilina resistentes mais frequentes no grupo 1 (38,7% x 5%, p=0,017) e quanto aos motivos da retirada do CVC, sendo a utilização da FAV maior no grupo 2 (0 x 33,3%, p<0,001) e a oclusão trombótica mais frequente no grupo 1 (52,6 x 25%, p=0,028). Na análise de regressão de Cox, o sítio em veia jugular foi fator protetor para retirada de cateter por todas as causas (HR: 0,41; IC 95% 0,19- 0,91) e por complicação mecânica (HR: 0,16; IC 95% 0,065-0,41) e apenas o IOS foi fator de risco para retirada do cateter por todas as causas (HR: 1,79; IC 95% 1,04-3,07) e por complicação mecânica (HR: 5,64; IC 95% 1,65-19,33). Conclusão: A eficácia de ambas as soluções (antibióticos e antimicrobianos não antibióticos) em lock foi semelhante na prevenção das infecções relacionadas ao CVC tunelizado para HD. Entretanto, no grupo gentamicina/cefazolina houve maior presença de cepas resistentes à oxacilina. O maior número de bactérias resistentes à oxacilina no grupo gentamicina/cefazolina alerta para riscos de indução de resistência bacteriana com uso profilático de lock com antibióticos em CVC de longa permanência. / Background: Hemodialysis (HD) is the most widely used renal replacement therapy modality, and the use of central venous catheters (CVC) has increased as primary form of vascular access for hemodialysis. Despite the immediate possibility of use, there is a strong association between CVC and bloodstream infection (BSI) high morbidity and mortality, so several trials have been directed at the prevention of catheter-related bloodstream infection (CRBI) on dialysis population, highlighting studies using prophylactic lock therapy. A number of substances has been tested as prophylactic lock therapy, but the comparison between antimicrobials and antibiotic drugs was not tested enough, and the best prophylactic lock solution remain undetermined. The aim of the study was to compare the efficacy of catheter-restricted filling using antibiotic solution (cefazolin plus gentamicin plus heparin) versus antimicrobial solution (taurolidine plus citrate) regarding CRBI rates and to identify its adverse effects, including bacterial resistance and thrombotic events. Methods: A Quasi-experimental study. Prospective and comparative, developed in two dialysis centers, including incidents long permanence CVC for HD. 145 CVC were implanted in 127 patients HD and followed up for 15 months. The patients were allocated in each group according the hemodialysis center: Group 1: 65 patients (77 CVC) using antibiotic lock solution (gentamicin 7,2mg /ml + cefazolin 12mg /ml + heparin 3500 IU /ml). Group 2: 62 patients (68 CVC) using taurolidine citrate + 4% + Heparin 500 IU /ml (Taurolock-TM-Hep 500). The incidence density of infection was calculated by the number of events per 1000 catheter-day. ICS, IOS and mechanical complication free survival curves were performed using the Kaplan Meyer method, as well as proportional hazards Cox model, including the following variables: group, catheter site, hemodialysis time to implant, comorbidities, age and CKD causal disease. Results: The two groups were similar for sex, age, causal disease, comorbidities and HD time. There was no difference between the groups regarding the prevalence of exit site infection (ESI) and BI as the same for the density of CRBI incidence (G1 = 0.79 events per 1000 day catheters x G2 = 1.10 events per 1000 day catheters, p =0.18) and ESI (G1 = 2.45 x G2 = 1.83 events per 1000 day catheters, p = 0.37). Infection free time and catheter withdrawal rate were similar between the groups. However, the groups differed for ESI agents, with gram-positive oxacillin-resistant more frequent in group 1 (31.8 x 5%, p = 0.003) and for the reasons for catheter removal, being AVF use more frequent in group 2 (0 x 33.3%, p<0.001) and mechanical complication in group 1 (52.6 x 25%, p= 0.028). In the Cox regression analysis, the jugular vein site was a protective factor for catheter removal from all causes (HR: 0.41, 95% CI 0.19-0.91) and mechanical complication (HR: 0, 16, 95% CI 0.065-0.41), and only IOS was a risk factor for catheter removal from all causes (HR: 1.79, 95% CI 1.04-3.07) and mechanical complication (HR: 5.64, 95% CI 1.65- 19.3). Conclusion: The efficacy of both lock solutions (antibiotics and antimicrobials no antibiotics) was similar in preventing infections related to tunneled CVC for hemodialysis. However, in group 1 there were more oxacilinresistant strains. The highest number of oxacilin-resistant bacteria in the gentamicin/cefazolin group warns against the risk of induction bacterial resistant with prophylactic use of lock with antibiotics in long-term CVC. / 2014/06140-1
137

Correção em tempo real das correntes distorcidas no enrolamento secundário de TCs com entreferro.

PEREIRA, Fagner de Araujo. 03 May 2018 (has links)
Submitted by Emanuel Varela Cardoso (emanuel.varela@ufcg.edu.br) on 2018-05-03T23:20:59Z No. of bitstreams: 1 FAGNER DE ARAUJO PEREIRA – TESE (PPGEE) 2016.pdf: 5563651 bytes, checksum: 359256a68bd0b865ecd15f6e1d7cb585 (MD5) / Made available in DSpace on 2018-05-03T23:20:59Z (GMT). No. of bitstreams: 1 FAGNER DE ARAUJO PEREIRA – TESE (PPGEE) 2016.pdf: 5563651 bytes, checksum: 359256a68bd0b865ecd15f6e1d7cb585 (MD5) Previous issue date: 2016-09-09 / É apresentada uma plataforma implementada com controladores digitais de sinal (DSCs – Digital Signal Controllers) desenvolvida para estudos do comportamento dinâmico em tempo real dos transformadores de corrente com entreferro, utilizados em sistemas de proteção e medição de redes de energia elétrica. Os algoritmos implementados simulam a corrente de defeito em um sistema de energia eléctrica, bem como a resposta transitória do transformador de corrente. Um método para corrigir a distorção da corrente secundária do TC com entreferro é apresentado, onde o fluxo residual é desprezível. Para estimar o fluxo, um enrolamento terciário deve estar disponível. Os erros de fase e de relação, bem como as distorções na corrente secundária devido à saturação do núcleo em situações de falta são adequadamente corrigidos pelo método. Vários casos foram testados e os resultados indicam que o método proposto é eficaz em melhorar o desempenho dos sistemas de protecção com base na medição de corrente. / A platform implemented with Digital Signal Controllers (DSCs) developed for real time studies of the dynamic behavior of the air-gapped current transformers (CTs) used in power grid protection and measurement systems is presented. The implemented algorithms simulate the fault current in an electric power system as well as the transient response of the current transformer. A method for correcting the CT secondary current distortion is presented in the case of gapped core where residual flux is negligible. To estimate the flux, a tertiary winding must be available. The ratio and phase errors, as well as the distortions in secondary current due the core saturation in fault situations are properly corrected by the method. Several cases were tested and the results indicate that the proposed method is very effective in improving the performance of protection schemes based on the current measurement.
138

Conversor buck utilizando célula de comutação de três estados /

Balestero, Juan Paulo Robles. January 2006 (has links)
Resumo: Este trabalho apresenta um novo conversor PWM CC-CC buck não isolado. O conversor é gerado a partir de uma célula de comutação de três estados, composta basicamente por dois interruptores ativos, dois passivos e dois indutores acoplados. Neste conversor apenas metade da potência da carga é processada pelos interruptores ativos, reduzindo assim a corrente de pico sobre estes à metade do valor da corrente de pico de saída, tornando-o importante para aplicações em potências mais elevadas. O volume dos elementos reativos (indutores e capacitores) é reduzido, pois, pela característica do conversor, a freqüência da ondulação da corrente e da tensão de saída é o dobro da freqüência de operação dos interruptores. Para uma menor freqüência de operação, diminuem-se as perdas na comutação. Devido à topologia do conversor, as perdas totais são distribuídas entre todos semicondutores, facilitando a dissipação de calor. Outra vantagem é possuir uma menor faixa de operação na região de descontinuidade em comparação com o conversor buck clássico, ou seja, a faixa de operação no modo de condução contínua é ampliada. É detalhada a abordagem através de análises qualitativa e quantitativa do emprego da célula de comutação de três estados no conversor buck, operando em toda faixa de variação da razão cíclica (0 .D .1). Além de toda a análise matemática e desenvolvimento através de simulação digital, um protótipo de 1kW foi implementado e testado em laboratório. Os principais resultados experimentais estão apresentados e discutidos neste trabalho. / Abstract: This work presents a new PWM DC-to-DC non-isolated buck converter. The converter is generated using the three-state switching cell, comprised of two active switches, two diodes and two coupled inductors. In this converter only part of the load energy is processed by the active switches, reducing the peak current in these switches to half of the value to the peak of the load current. This feature permits to operate this topology in larger power levels. The volume of the power reactive elements (inductors and capacitors) is also decreased since the ripple frequency on the output is twice the switching frequency. For a lower operating frequency, the switching losses are decreased. Due to the topology of the converter, the total losses are distributed among all semiconductors, facilitating the dissipation of heat. Another advantage of this converter is the smaller region to operate in discontinuous conduction mode when compared to conventional buck converter or, in other words, the operation range in continuous conduction mode is enlarged. The theoretical approach is detailed through qualitative and quantitative analyses of the employment of the three states switching cell in the buck converter, operating in the entire every variation range of the duty cycle (0 < D < 1). Besides the mathematical analysis and development through digital simulation, a prototype of 1kW was implemented and tested at laboratory. The main experimental results are introduced and discussed in this work. / Orientador: Falcondes José Mendes de Seixas / Coorientador: Grover Victor Torrico Bascopé / Banca: Dionízio Paschoareli Junior / Banca: João Onofre Pereira Pinto / Mestre
139

Tomografia por biosusceptometria de corrente alternada /

Fonseca Filho, Paulo Roberto da. January 2014 (has links)
Orientador: José Ricardo de Arruda Miranda / Banca: Oswaldo Baffa Filho / Banca: Roberto Morato Fernandez / Banca: Fernando Gomes Romeiro / Banca: Valmir Fadel / Resumo: A busca por novos métodos de imagens, principalmente os livres de radiação ionizante, são importantes tanto pelas instrumentações, quanto para as finalidades. A Biosusceptometria de |Corrente Alternada (BAC) possui versatilidade, sensibilidade, baixo custo e têm sido amplamente utilizada na aquisição de imagens para estudos nas áreas de gastrenterologia, fisiologia, farmacologia e farmácia. O objetivo deste trabalho foi caracterizar sistemas de BAC na produção de imagens tomográficas de objetos simuladores, propondo a viabilidade da técnica de tBAC - tomografia por biosusceptometria de Corrente Alternada. Para tanto, os gradiômetros de dois sistemas BAC com 13 e 37 canais com compensação de campo de excitação foram avaliados quanto à sua sensibilidade e resolução para produzir imagens de simuladores de barras e cilíndri-cos. Foi possível reconstruir imagens de todos os objetos com boa correlação entre a imagem e as caracte-rísticas físicas dos objetos (forma e concentração de traçador magnético). As melhores imagens foram pro-duzidas quando foi utilizada aquisição multicanal no sistema de BAC com 37 sensores utilizando compen-sação de campo, os quais possuem menores diâmetros. Dessa forma verificou-se que os sistemas BAC podem ser empregados com sucesso para produzir imagens tomográficas de objetos com pequena quanti-dade de traçador magnético, o que viabiliza sua aplicação futura em pequenos animais, farmacotecnia ou ainda ensaios não destrutivos / Abstract: The development of new imaging methods, especially those that are free of ionizing radiation, constitute a very important topic because for both instrumentation development and its applications. The Alternating Current Biosusceptometry (ACB) has versatility, sensibility and low cost and has been widely used on image acquisition on gastroenterology, physiology, pharmaceutics and pharmacology researches. The aim of this project was to characterize ACB systems to produce tomographic images of simulating objects ver-ifying the technical viability of the AC Biosusceptometry Tomography (ACBT). The capability of ACB gradiometers of 13 and 37 channel systems with compensation field to reconstruct images of bars and cy-lindrical phantoms were evaluated, especially sensibility and resolution. It was possible to reconstruct im-ages from all objects with good correlation between the image and the phantom (geometry and magnetic tracer concentration). Better results were observed while using multichannel acquisition on 37-channel sys-tem with active excitation magnetic field. Therefore we verified that ACB systems can be successfully used on tomographic imaging of objects with small quantities of magnetic tracer, which is viable to future ap-plication on small animal physiology, pharmaceutics or non-destructive evaluation research / Doutor
140

Otimização e aperfeiçoamento BAC pra estudos envolvendo o trato gastrintestinal /

Agostinho, Marcelo Rodrigues. January 2011 (has links)
Orientador: José Ricardo de Arruda Miranda / Banca: Eder Rezende / Banca: Fabiano Carlos Paixão / Resumo: A utilização de técnicas não invasivas, de baixo custo e inócuas ao indi-víduo proporcionam um grande desafio para o estudo do trato gastrintestinal. Métodos biomagnéticos como a BAC trazem todas essas vantagens e incluem a possibilidade de expansão para novos estudos, arranjos instrumentais e mo-delos biológicos. A consolidação dessa técnica nos últimos anos permitiu a ampliação dos estudos na área farmacêutica, avaliações após alterações nas condições fisiológicas e mesmo após administração de drogas, fornecendo subsídios para uma melhor interpretação dos parâmetros motores do trato gas-trintestinal. As imagens de traçadores e marcadores magnéticos no trato gas-trintestinal proporcionadas pela BAC foi um importante aspecto explorado, no entanto, houve a necessidade de aperfeiçoar a instrumentação para obter me-lhores e também novos resultados. A proposta de implementação de algumas melhorias nesta instrumentação através de implementação de novo arranjo de bobina excitadora, cancelamento de ruído respiratório e nova eletrônica de de-tecção permitiram que os dados in vitro e in vivo refletiram numa melhor quali-dade de sinais e imagens obtidos por este técnica. A BAC multi-sensores é uma ferramenta valiosa com vasta aplicabilidade para aplicação em tecnologia farmacêutica e em fisiologia do trato gastrintestinal / Abstract: The use of non-invasive techniques, at low cost and harmless to the indi-vidual, provides a great challenge for the study of the gastrointestinal tract. Biomagnetic methods such as the BAC have all these advantages and also include the possibility of expanding to new studies, to instrumental ar-rangements and to biological models. The consolidation of this technique in re-cent years allowed the extension of studies in the pharmaceutical field, after rating changes in physiological conditions and even after drug administration, supporting a better interpretation of the motor parameters of the gastrointestinal tract. The images of tracers and magnetic markers in the gastrointestinal tract offered by the BAC was an important aspect explored. However, there was a necessity of improving the equipment in order to obtain new and better re-sults. The proposal to implement some improvements in this equipment through implementation of the new exciter coil arrangement, the cancellation of the noise of breathing, and the new electronics of detection have allowed that the data in vitro and in vivo reflected a better quality of signals and images obtained by this technique. The BAC multi-sensors is a valuable tool with wide applica-bility to pharmaceutical technology and physiology of the gastrointestinal tract / Mestre

Page generated in 0.0898 seconds