• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 3
  • Tagged with
  • 10
  • 10
  • 9
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Physique et modélisation d'une source d'ions négatifs pour l'injection du faisceau de neutres sur ITER / Physics and modelling of a negative ion source for the ITER neutral beam injection

Kohen, Nicolas 22 January 2015 (has links)
La source d'ions des injecteurs de neutres d'ITER devra produire un fort courant d'ions négatifs de deutérium qui seront accélérés puis neutralisés afin d'obtenir un faisceau d'atomes qui chauffera le plasma thermonucléaire. Un plasma froid d'hydrogène à basse pression et forte puissance est généré par induction dans la source et les ions négatifs sont produits par des réactions en volume et en surface et extraits à travers une série de grilles électrostatiques. Cette thèse est consacrée à la modélisation de ce plasma, afin d'étudier des phénomènes peu abordés à ce jour : aspect hors équilibre des espèces neutres, déplétion et chauffage du gaz, génération et transport des atomes, et génération des ions négatifs sur les parois. Un code fluide bidimensionnel de simulation plasma a pour cela été modifié afin de simuler la cinétique des espèces neutres au moyen d'un module Direct Simulation Monte-Carlo et a été utilisé pour simuler le plasma de manière auto-cohérente. / The ion source of the ITER neutral beam injectors will have to deliver a high current of negative deuterium ions which will be accelerated and neutralized, and the resulting atom beam will heat the thermonuclear plasma. A low pressure and high power cold hydrogen plasma is inductively generated in the source and negative ions are produced by volume and surface reactions and are extracted through a set of electrostatic grids. This thesis aims at modelling this plasma, and focuses on topics that haven't been studied much before : out of equilibrium neutral kinetics, gas heating and depletion, atoms production and transport, and negative ions generation on the walls. To this end, a two-dimensional fluid plasma code has been modified to simulate the neutrals kinetics with a Direct Simulation Monte Carlo module and has been used to perform self-consistent simulations of the plasma.
2

DETECTION, EN TEMPS REEL, D'ELEMENTS METALLIQUES PRESENTS DANS LES REJETS ATMOSPHERIQUES INDUSTRIELS PAR TORCHE A PLASMA A COUPLAGE INDUCTIF

Vacher, Damien 21 December 2001 (has links) (PDF)
Ce travail est consacré à l'élaboration d'un procédé de détection en temps réel des polluants métalliques présents dans les effluents gazeux industriels. La méthode de mesure est la spectrométrie d'émission atomique couplée à une torche ICP (Inductively coupled Plasma).<br />La technologie des lits fluidisés est utilisée comme système d'introduction des particules métalliques dans la torche ICP, l'intérêt du principe de détection reposant sur l'affranchissement de la procédure usuelle d'étalonnage du système analytique.<br />Les résultats sont présentés en deux parties. La première concerne le diagnostic de plasmas formés de différents mélanges N2/O2 dont un correspond à l'air pur, la seconde présente la mise en œuvre du procédé de détection en temps réel à partir des rapports d'intensités des raies spectrales de l'élément métallique avec celles de l'élément plasmagène (argon ou air pur).<br /> L'étude du diagnostic de plasmas composés de mélanges N2/O2 concerne la détermination de la température d'excitation atomique à partir des raies spectrales de l'élément cuivre et l'évaluation du degré de déséquilibre thermique q =Te/Th régnant au sein du plasma. Ce dernier est obtenu en considérant les enthalpies massiques des différents mélanges N2/O2. L'existence d'un léger déséquilibre thermique (q£1,2) est mis en évidence.<br /> L'étude de la détection en temps réel par torche ICP, sans étalonnage du système, repose sur trois points :<br /> - le traitement des données spectroscopiques pour déterminer les valeurs des rapports d'intensités de raies spectrales;<br /> - l'insertion des rapports d'intensités et des caractéristiques du plasma (argon ou air pur) dans un code de calcul de composition du plasma;<br /> - la comparaison des valeurs de débits massiques des polluants métalliques, en temps réel, obtenues expérimentalement avec celles calculées à partir des formules d'élutriation, terme qui définit le phénomène d'entraînement des particules hors du lit fluidisé.<br />Les résultats ont permis de montrer la similarité de la réponse du système analytique entre l'utilisation du plasma d'argon et celui d'air.
3

Contribution à l'étude des courants de palier dans les moteurs de traction

Postariu, Dragos Mihai 23 October 2009 (has links) (PDF)
La fiabilité est l'un des principaux objectifs de tout fabricant de moteurs électriques. Au cours des 20 dernières années, l'apparition de l'électronique de puissance dans la partie alimentation es moteurs électriques de traction a donné la possibilité de contrôle de couple à toute vitesse de rotation. En utilisant ce type d'alimentation pour les moteurs asynchrones, ceux-ci sont devenus une alternative à coût réduit et très fiable aux moteurs synchrones utilisés auparavant dans la traction. L'inconvénient de l'électronique de puissance, c'est que des fronts dV/dt sont appliqués aux moteurs. Ces fronts excitent les couplages parasites dans les moteurs, de sorte que les courants vagabonds peuvent circuler dans le moteur, et passer par les roulements. Cela amène à une augmentation du taux de défaillance. L'objectif de ce travail est de développer un modèle analytique, utilisable à partir de la phase de conception du moteur, qui permet de prévoir le type et la quantité des courants qui sont susceptibles de se produire.
4

Nanofils de SiC : de la croissance aux dispositifs associés

Choi, Jihoon 21 March 2013 (has links) (PDF)
Les nanostructures de semi-conducteurs de faibles dimensions (comme les nanofils(NFs)) sont devenues l'objet de recherches intensives pour explorer de nouveaux phénomènes émergents à l'échelle nanométrique et sonder leur possibilités d' utilisation dans l'électronique du futur. Parmi les différents nanofils semi-conducteurs, SiC a des propriétés très particulières, comme une large bande interdite, une excellente conductivité thermique, un haut champ électrique de claquage, une stabilité chimique et physique, une haute mobilité des électrons et une haute biocompatibilité.Nous proposons dans cette étude ; d'examiner une nouvelle approche pour fabriquer des nanostructures de SiC par l'approche " top-down ". Cela permet l'élaboration de nanostructures cristallines de SiC de haute qualité monocristalline avec un niveau de dopage contrôlé. Le comportement de nanostructures de SiC gravées a également été étudié en fonction de polytypes et des orientations cristallographiques.Nous avons également étudié les trois principaux sujets de SiC nano-devices pour atteindre une excellente performance. Pour répondre à ces questions, deux types de SiC nanoFET (SiC NFFET et SiC NPFET) ont été fabriqués et caractérisés par l'utilisation de nanofils de SiC et de nanopiliers de SiC préparés respectivement par les méthodes " bottom-up " et " top-down ".
5

Synthèse et régulation des sélénoproteines mammifères / Synthesis and regulation of mammalian selenoproteins

Sonet, Jordane 26 September 2017 (has links)
Le Sélénium (Se) est un oligo-élément essentiel qui est incorporé dans une famille indispensable de protéines, les sélénoprotéines, sous la forme d’un résidu acide aminé rare, la sélénocystéine. Dans les études épidémiologiques, il apparait clairement que des faibles niveaux de sélénium dans les fluides biologiques sont associés avec (i) une augmentation du risque de cancers (colon, prostate, poumon) et de maladies cardiovasculaires, (ii) une altération de la fonction immunitaire et (iii) finalement une réduction de l’espérance de vie. Dans le génome humain, vingt-cinq gènes de sélénoprotéine ont été identifiés. Ces gènes expriment, de par la complexité de la régulation du génome, de nombreuses isoformes de chacun des 25 gènes pour constituer le sélénoprotéome. Quand la fonction est connue, ces protéines participent à des processus essentiels de défense antioxydante, d’homéostasie redox et de signalisation redox. Ces enzymes sont finement régulées par l’apport en sélénium et d’autres stimuli cellulaires. Pour comprendre la fonction et la régulation du sélénoprotéome humain, qui est exprimé à un niveau trace, il s’avère critique de développer une stratégie innovante basée sur une approche multidisciplinaire de détection et quantification du sélénium par différents outils de spectrométrie de masse élémentaire (ICP MS) et moléculaire (ESI-MS/MS). Tout d’abord, le sélénium possède un profil isotopique bien particulier avec six isotopes stables (74Se, 76Se, 77Se, 78Se, 80Se and 82Se) qui sert de signature dans nos analyses en ICP-MS ou en ESI-MS/MS. En parallèle, l’utilisation de sélénium isotopiquement enrichi permet également des marquages cellulaires en multiplexing. Ainsi, en couplant des méthodes de séparation en phase liquide (HPLC) ou en gel d’électrophorèse (IEF ou SDS-PAGE échantilloné par ablation laser) avec l’ICP MS, nous avons mis au point plusieurs méthodes permettant la détection de plusieurs sélénoprotéines de manière simultanée dans différentes lignées cellulaires. De plus, un médicament sélénié sous forme de triglycéride obtenu via un mélange d’huile de tournesol et de sélénite a été testé comme source de sélénium non toxique pouvant stimuler la production de sélénoprotéines. Plusieurs lignées cellulaires humaines cancéreuses et non-cancéreuses ont été expérimentées avec succès permettant de valider cette nouvelle source de sélénium dans la synthèse des sélénoprotéines. / Selenium (Se) is an essential trace element, which is incorporated as a rare aminoacid, selenocysteine, in twenty five selenoproteins, to constitute the selenoproteome. Selenoprotein family is one of the most important bioactive form of selenium in human health. Initially demonstrated in Kashin Beck and Keshan diseases, selenium deficiency is associated with several pathological conditions, including cancer, neurodegenerative diseases, immune and muscular disorders. Chronic selenium deficiency is hypothesized to decrease antioxidant defenses and redox regulatory pathways through a dysregulation of selenoprotein expression. We are interested in understanding the synthesis and regulation of human selenoproteins, which is critically dependent on the availability of adequate analytical methodology. To understand the function and regulation of human selenoproteome, which is expressed at a trace levels, it appears critical to develop innovative strategies based on a multidisciplinary approach to detect and quantify selenium by various elemental and molecular mass spectrometer tools. First, selenium has a particular isotopic profile with six stable isotope (74Se, 76Se, 77Se, 78Se, 80Se and 82Se) used as a signature in our analysis with ICP-MS or ESI-MS/MS. In parallel, the use of isotopically enriched selenium also allows cellular labelling and tracing of selenoproteins and other seleno-coupounds. By coupling liquid phase separation methods (HPLC) with specific mass spectrometry analytical tools, we have developed several methods for detecting several selenoproteins simultaneously in various human cell lines.
6

Applications de la vaporisation électrothermique couplée à la technique ICP-AES pour la détermination élémentaire dans les végétaux : une stratégie permettant l’analyse directe des échantillons à l’état solide / Application of the electrothermal vaporization method coupled with simultaneous inductively coupled plasma atomic emission spectrometry for the elemental determinations in plant samples : A strategy for the direct analysis of samples in the solid state.

Masson, Pierre 19 May 2014 (has links)
Parmi les systèmes dédiés à l’analyse directe des solides, la vaporisation électrothermique occupe une place de choix. Elle offre plusieurs avantages. Le temps de préparation des échantillons est considérablement réduit. Il n’y a pas de dilution induite par la minéralisation et les risques de pertes ou de contaminations durant cette étape sont éliminés. Son principe de fonctionnement consiste à transformer, par chauffage, quelques milligrammes d’échantillon en un aérosol, qui est ensuite transporté dans un spectromètre d’émission atomique par plasma à couplage inductif, où la composition élémentaire est mesurée. Une première étude fondamentale a permis de mieux comprendre la dynamique de l’aérosol formé et de définir les meilleures conditions opératoires. L’utilisation de cette technique pour la détermination élémentaire dans les végétaux a présenté cependant des difficultés supplémentaires : difficulté d’étalonnage, effets de matrice et grandes variabilités sur les concentrations mesurées. L’utilisation d’un support de cellulose pour les solutions étalons a permis d’harmoniser les conditions de formation de l’aérosol pour l’échantillon et pour l’étalon, et d’obtenir ainsi des résultats justes. Les effets de matrices ont pu être considérablement réduits par une calcination préalable des échantillons. Le manque de précision des mesures, causée par le manque d’homogénéité des échantillons, a pu être limitée en de réduisant significativement la taille des particules solides. Ces résultats obtenus sur des poudres ont permis d’autres applications comme l’analyse d’échantillons entiers ou la cartographie de la composition chimique d’organes végétaux. / Among the systems dedicated to the direct analysis of the solids, electrothermal vaporization takes up a place of choice. It offers several advantages. The preparation time of the samples is considerably reduced. There is no dilution induced by the digestion and the risks of losses or contaminations during this stage are eliminated. Its functioning consists to convert, by heating, a few milligrams of sample into an aerosol which is then transported in an inductively coupled plasma atomic emission spectrometer, where the elemental composition of the sample is determinate. A first fundamental study allowed to better understand the dynamics of the formed aerosol and to define the best operating conditions. However, the use of this technique to determine the elemental composition of solid plant samples presented additional difficulties: difficulty of calibration, matrix effects and important imprecision on the measured concentrations. The use of a cellulose support for the standard solutions allowed to harmonize the formation of the aerosol between the sample and the standard, and to obtain accurate results. The matrix effects can be considerably reduced by a preliminary dry-ashing of the samples. The variability of measurements, caused by the lack of homogeneity of the samples, was limited by reducing significantly the size of the solid particles. These results, obtained on powders, allowed other applications as the analysis of whole plant samples or the imaging of the chemical composition of plant organs.
7

Nanofils de SiC : de la croissance aux dispositifs associés / SiC Nanowires : from growth to related devices

Choi, Jihoon 21 March 2013 (has links)
Les nanostructures de semi-conducteurs de faibles dimensions (comme les nanofils(NFs)) sont devenues l'objet de recherches intensives pour explorer de nouveaux phénomènes émergents à l'échelle nanométrique et sonder leur possibilités d’ utilisation dans l'électronique du futur. Parmi les différents nanofils semi-conducteurs, SiC a des propriétés très particulières, comme une large bande interdite, une excellente conductivité thermique, un haut champ électrique de claquage, une stabilité chimique et physique, une haute mobilité des électrons et une haute biocompatibilité.Nous proposons dans cette étude ; d'examiner une nouvelle approche pour fabriquer des nanostructures de SiC par l'approche « top-down ». Cela permet l'élaboration de nanostructures cristallines de SiC de haute qualité monocristalline avec un niveau de dopage contrôlé. Le comportement de nanostructures de SiC gravées a également été étudié en fonction de polytypes et des orientations cristallographiques.Nous avons également étudié les trois principaux sujets de SiC nano-devices pour atteindre une excellente performance. Pour répondre à ces questions, deux types de SiC nanoFET (SiC NFFET et SiC NPFET) ont été fabriqués et caractérisés par l'utilisation de nanofils de SiC et de nanopiliers de SiC préparés respectivement par les méthodes « bottom-up » et « top-down ». / Low dimensional semiconductor nanostructures, such as nanowires (NWs), have become the focus of intensive research for exploring new emergent phenomena at the nanoscale and probing their possible use in future electronics. Among these semiconductor NWs, Silicon Carbide (SiC) has very unique properties, such as wide bandgap, excellent thermal conductivity, chemical and physical stability, high electron mobility and biocompatibility. These factors makes SiC a long standing candidate material to replace silicon in specific electronic device applications operating in extreme conditions or/and harsh environments. SiC nanostructures have been studied extensively and intensively over the last decade not only for their fabrication and characterization, but also for their diverse applications. I have outlined the growth of SiC nanostructures based on different growth methods, a noteworthy feature of their characteristic properties and potential applications in the chapter one. As-grown SiC NWs fabricated by bottom-up method present a high density of structural defects, such as stacking faults. This kind of defect is one of the factors which lead to poor electrical performance (such as weak gate effect and low mobility) of the related devices. Therefore, it is required to develop a high quality of SiC nanostructures with low density of the structural defects using an alternative method, such as top-down process. Main objectives of this thesis are divided into three main parts. The first part of the thesis (Chapter two), we present the simulation results of the electrical transport and thermoelectric properties of SiC NWs. I have investigated the thermoelectric enhancement by studying the complex interplay of the size of NWs, temperature and surface roughness. Our simulation results show that the ZT of C terminated SiC NW (2.05×2.05 nm2) reaches a maximum value of 1.04 at 600K. The second part of the thesis (Chapter there) is devoted to the fabrication of high quality SiC nanostructures with controlled doping level. I have developed a top-down fabrication technique for high quality nanometer scale SiC nanopillars (NPs) using inductively coupled plasma etching. The etching behavior of SiC NPs has also been studied depending on polytypes and crystallographic orientations. Under the optimal etching conditions using a large circular mask pattern with 370 nm diameter, the obtained 4H-SiC nanopillars exhibit high anisotropy features (6.4) with a large etch depth (>7μm). A hexagonal, rhombus and triangle based pillar structures have been obtained using α-SiC (0001), 3C-SiC (001) and 3C-SiC (111) substrates, respectively. The last part of the thesis (Chapter four) is dedicated to the design and the electrical characterization of SiC nanodevices. To investigate the electrical properties of SiC nanostructures, two different kinds of SiC nanoFETs (SiC NWFET and SiC NPFET) have been fabricated by using SiC NWs and SiC NPs prepared via bottom-up method and top-down methods, respectively. In case of SiC NWFET, low resistivity ohmic contacts (378 kΩ) have been obtained after the annealing at 650 °C. Ni silicide intrusion into the SiC NW channel has been observed the annealing at 700 °C. This temperature is compared to one of other group IV materials. In case of SiC NPFET, two different types of NPFET (3C-SiC (001) and 4H-SiC (0001)) have been fabricated using our SiC nanopillars, obtained by top-down approach. The estimated values of the field-effect carrier mobility are 232.7 cm2⋅V-1s-1 for 3C-SiC (001) NPFET (#2) and 53.6 cm2⋅V-1s-1 for 4H-SiC (0001) NPFET, which is higher than the best values reported in the literature (15.9 cm2⋅V-1s-1).
8

Optimisation d’un générateur de microgouttelettes couplé à un appareil de spectrométrie de masse à plasma d’argon à couplage inductif (ICP-MS) pour l’analyse de nanoparticules

Fournel, François 04 1900 (has links)
No description available.
9

Processus géodynamiques, systèmes pétroliers, problématiques environnementales, ou de la versatilité des isotopes du plomb comme outils de traçage / Lead isotopes, versatile tracers of geodynamic processes, petroleum systems, and environmental issues

Fetter, Nadège 30 September 2019 (has links)
Le Pb est omniprésent dans les échantillons terrestres et sa relation avec ses ascendants radioactifs, l’U et le Th, en fait un marqueur de choix des processus géodynamiques.L’équipe lyonnaise de Janne Blichert-Toft et Francis Albarède a démontré, à travers une vaste compilation de données bibliographiques accompagnée de la production de nouvelles mesures, une correspondance entre la répartition des valeurs de composition isotopique du Pb dans la croûte continentale et la localisation de figures tectoniques majeures sur plusieurs continents (Bouchet et al., 2014 ; Blichert-Toft et al., 2016 ; Delile et al., 2014). L’existence de ces "provinces géochimiques" démontre l’intérêt des isotopes du Pb comme outil pour mieux comprendre comment l’histoire tectonique d’une région façonne la géochimie de ses continents. Un premier volet de ces travaux de thèse visait à compléter la base de données existante des compositions isotopiques du Pb dans la croûte continentale européenne, grâce à l’analyse de 104 échantillons de feldspaths potassiques issus de granites principalement originaires de Catalogne, de Corse, de Galice et de Kabylie, jusqu’ici restées en blanc sur les cartes précédemment établies. Les cartes ainsi obtenues, illustrant la répartition à travers l’Europe et le bassin méditerranéen des valeurs des "paramètres géochimiques" définis par Albarède et al. (2012), exprimant à partir des rapports isotopiques du Pb mesurés l’âge modèle de la roche et les fractionnements entre l’U, le Th et le Pb enregistrés en son sein, confirment le potentiel des isotopes du Pb comme traceurs robustes de l’héritage tectonique d’une région.Mais le cœur de cette thèse a été d’appliquer cet outil reliant chimie et histoire géodynamique que sont les isotopes du Pb à un type d’échantillon géologique pour lequel des analyses de haute précision de la compositions isotopique en Pb n’avaient jamais été entreprises jusqu’à maintenant : les pétroles bruts. Pour cela, il a fallu développer une méthode analytique novatrice permettant d’extraire le Pb de quelques millilitres de pétrole brut vers une solution aqueuse adaptée aux protocoles habituels de purification indispensables à des analyses isotopiques du Pb à haute précision par MC-ICP-MS (Fetter et al., 2019). Cette méthode a ensuite été appliquée à un total de 211 échantillons de pétrole brut issus de partout dans le monde. Des échantillons de roches mères d’hydrocarbures (schistes noirs) ont également été analysés afin de compléter les premières interprétations des résultats. Ce jeu de données unique met en évidence que le Pb contenu dans les pétroles bruts résultait du mélange d’au moins trois composantes d’âges modèles distincts : le pôle le plus radiogénique a été identifié comme associé aux roches mères des pétroles, tandis que les deux autres, d’âges modèles paléozoïque et protérozoïque, suggèrent des interactions conséquentes entre le pétrole et les roches encaissantes et sous-jacentes. Un nouveau modèle de migration du pétrole depuis sa roche mère a donc été proposé (Fetter et al., soumis), prenant en compte la forte implication des eaux circulant en profondeur dans les bassins sédimentaires en faisant intervenir un phénomène grandement négligé jusqu’à maintenant : la solubilité mutuelle de l’eau et du pétrole à haute température.La mise en évidence d’une dynamique complexe du Pb dans les pétroles bruts invalide une utilisation de ces derniers comme alternative aux feldspaths potassiques pour obtenir des données isotopiques en Pb fiables sur la croûte continentale européenne située sous les bassins sédimentaires. Cependant, elle ouvre de nouvelles portes quant à l’utilisation jusqu’ici inexplorée des isotopes du Pb comme traceurs de phénomènes de pollution associés à une prospection pétrolière peu responsable. / Lead is ubiquitous in terrestrial samples and its relationship to its radioactive ascendants, U and Th, makes it a prime tracer of geodynamic processes.The team of Janne Blichert-Toft and Francis Albarède, based in Lyon (France), has demonstrated on several continents, through large compilations of literature data supplemented by new measurements, a correspondence between the distribution of Pb isotopic compositions in the continental crust and major tectonic features (Bouchet et al., 2014 ; Blichert-Toft et al., 2016 ; Delile et al., 2014). The existence of these "geochemical provinces" has firmly established the potential of Pb isotopes as a tool for understanding how the tectonic history of a given region shaped its geochemistry. A first aspect of this PhD aimed at complementing the existing database of Pb isotopic compositions of the European continental crust through the analysis of 104 K-feldspar samples separated from granites originating mainly from Catalonia, Corsica, Galicia, and Kabylie, up until this PhD blank areas on the compiled map. The resulting updated maps showing the distribution throughout Europe and the circum-Mediterranean area of the "geochemical parameters" defined by Albarède et al. (2012), which derive a model age and fractionations between U, Th, and Pb from measured Pb isotopic ratios, confirm the potential of Pb isotopes as powerful tracers of the tectonic heritage of a given region.The core of this PhD, however, was to apply this tool connecting chemistry and geodynamic history to a type of geological sample so far never analyzed for high-precision Pb isotopic compositions: crude oil. To achieve this goal, a novel analytical method was developed which allows the extraction of Pb from a few milliliters of crude oil into an aqueous solution suitable for the standard Pb purification protocol essential for high-precision Pb isotope analysis by MC-ICPMS (Fetter et al., 2019). This method was then applied to a total of 211 crude oil samples from around the world. Hydrocarbon source rocks (black shales) also were analyzed. This unique data set reveals that Pb in crude oil results from the mixing of at least three endmembers of distinct model ages: the more radiogenic endmember is identified as the oil source rocks, while the other two components, of Paleozoic and Proterozoic ages, suggest considerable interactions between crude oil and the surrounding and underlying rocks. A new model was hence proposed for oil migration (Fetter et al., submitted), taking into account the key role of deep-seated waters circulating through the sedimentary basin by calling on a long-neglected phenomenon: mutual solubility of water and oil at high temperatures.Bringing to light the complex dynamics of Pb in crude oil invalidates the use of crude oil as an alternative to K-feldspars to obtain the Pb isotopic signature of the continental crust underlying sedimentary basins. However, it opens up new promising avenues for the yet unexplored use of Pb isotopes as tracers of irresponsible oil prospection related pollution.
10

Détermination du destin des nanoparticules d'argent dans les eaux usées et dans les biosolides en utilisant la microscopie en champ sombre et analyse hyperspectrale

Théoret, Trevor 12 1900 (has links)
No description available.

Page generated in 0.1241 seconds