Spelling suggestions: "subject:"inventarios"" "subject:"comentarios""
211 |
Avaliação de protocolos para colagem de bráquetes cerâmicos e remoção do adesivo remanescente com vistas á preservação da integridade de esmalte dentárioVianna, Alexandre Protásio [UNESP] 08 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:23Z (GMT). No. of bitstreams: 0
Previous issue date: 2013-03-08Bitstream added on 2014-06-13T19:07:08Z : No. of bitstreams: 1
vianna_ap_dr_arafo.pdf: 843063 bytes, checksum: 4531dd78f0e6348ef44fc614df388067 (MD5) / Introdução: Este estudo teve como objetivos: Avaliar a influência de diferentes protocolos de condicionamento do esmalte e de cura luminosa dos sistemas adesivos testados, na resistência da colagem de bráquetes de cerâmica ao cisalhamento; na ocorrência de fraturas de esmalte e na quantidade de adesivo remanescente. Além disso, o Método dos Elementos Finitos foi empregado para analisar como os esforços relativos à descolagem atuaram na superfície do esmalte. Com auxílio da Microscopia eletrônica de varredura, avaliou-se a ação de 05 métodos para remoção da camada de adesivo remanescente quanto às alterações geradas nas características superficiais originais do esmalte e quanto ao tempo de execução dos procedimentos. Material de Método: 40 bráquetes Inspire IceTM, 40 bráquetes ClarityTM e 40 bráquetes GeminiTM foram aleatoriamente colados a 120 pré-molares com faces vestibulares hígidas, seguindo diferentes protocolos de condicionamento do esmalte e de fotopolimerização. Essas colagens foram testadas em ensaio mecânico por cisalhamento e também analisadas pelo método dos elementos finitos. Além disso, 25 molares permanentes com faces vestibulares hígidas passaram pela remoção de camadas padronizadas de adesivo remanescente com 05 métodos diferentes. As superfícies iniciais e finais de cada dente foram avaliadas por meio da microscopia eletrônica de varredura. O tempo gasto na execução de cada procedimento foi também avaliado. Resultados: As colagens com o TPSEP apresentaram menores valores de resistência da colagem ao cisalhamento e não estiveram associadas a fraturas de esmalte. Houve coincidência entre o modo de descolagem dos braquetes e a distribuição dos esforços na superfície do modelo 3D. As menores alterações à superfície do esmalte foram geradas... / Introduction: The aims of this study were to evaluate the influence of different protocols for enamel acidic etching and for light-curing of the adhesive systems tested about: shear bond strength of ceramic brackets; occurrence of enamel fractures and adhesive remnant index. Finite element method was also used to identify how debonding efforts act on enamel surface. Scanning Electron Microscopy was applied to assess the changes observed on original enamel surface characteristics generated by 05 methods for residual adhesive removal. The chair time related to the 05 methods under study was also evaluated. Material and Methods: 40 Inspire Ice Brackets; 40 Clarity Brackets and 40 metal Brackets (Gemini) were randomly bonded to 120 bicuspides, using different protocols of enamel conditioning and photo-activation. 25 permanent molars were submitted to the removal of standardized adhesive layers, using 05 different methods. Initial and final surfaces were comparatively evaluated by scanning electron microscopy. The procedures chair times were also assessed. Results: Transbond Plus Self-etching Primer promoted bracket bonding with lower shear bond strengths and debonding procedures without enamel fractures. FEM analysis showed coincidence among efforts distribution simulated over the tridimensional model surfaces and the real debonding damages caused on enamel. The multi-blade carbide bur in low hand-piece speed caused lower alterations over enamel original surface. Conclusion: TPSEP seemed to be the adequate method for bracket bonding; metallic bracket bonding showed lower shear bond strength without primer light-curing but it was not true for the ceramic brackets; chair time of the procedure and the final aspect of enamel surface demonstrated... (Complete abstract click electronic access below)
|
212 |
Utilização de enxerto ósseo autógeno, biovidros e cimento de fosfato de cálcio em defeitos ósseos criados cirurgicamente em mandíbulas de macacos Cebus apella. Estudo histológicoCancian, Daniela Cristina Joannitti [UNESP] 04 April 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:28Z (GMT). No. of bitstreams: 0
Previous issue date: 2002-04-04Bitstream added on 2014-06-13T20:25:02Z : No. of bitstreams: 1
cancian_dcj_dr_arafo.pdf: 701669 bytes, checksum: fd8aefd8d48f51c10e40c62ed9f6db8a (MD5) / A proposição deste estudo foi avaliar histologicamente a efetividade do PerioGlass, Fillerbone e Bone Source no preenchimento de cavidades ósseas cirurgicamente criadas em mandíbulas de macacos adultos jovens Cebus apella. Foram criadas duas cavidades transfixantes de 5mm de diâmetro nos ângulos mandibulares. Os defeitos ósseos foram preenchidos aleatoriamente e os grupo divididos da seguinte forma: Grupo I - cavidades preenchidas com osso cortiço-medular autógeno de tíbia; Grupo II - cavidades preenchidas com cimento de fosfato de cálcio (Bone Source); Grupo III - cavidades preenchidas com vidro bioativo (Fillerbone); Grupo IV - cavidades preenchidas com vidro bioativo (PerioGlass). Após 180 dias os animais foram sacrificados, as peças removidas e processadas para obtenção de cortes histológicos. A análise histológica dos resultados demonstrou que a utilização de enxerto ósseo autógeno permitiu reparação total do defeito ósseo; os materiais Fillerbone e PerioGlass permitiram reparo total dos defeitos com íntimo contaato dos grânulos dos materiais com o tecido ósseo neoformado; o material Boné Source não permitiu reparação do defeito ósseo ocorrendo preenchimento do defeito por tecido conjuntivo fibroso e foi em grande parte reabsorvido. / The present study evaluated histological results of filling with autogenous bone, PerioGlass, Fillerbone and Bone Source in bone cavities surgically created in mandible of Cebus apella Monkeys. The surgical cavities were prepared through both mandibular cortices, with a diameter of 5mm, inthe mandibular angle region. The cavities were randomized filled and the groups divided according to the material employed as follow: Group I - Filled with tibial autogenous corticocancellous bone; Group II - Filled with calcium phosphate cement (Bone Source); Group III - Filled with bioactive glass (Fillerbone); Group IV - Filled with bioactive glass (PerioGlass). After 180 days the animals were sacrificed and the specimens followed routine laboratory procedures for hematoxilin/eosin staining and histological evaluation. The histological analysis showed that the autogenous bone allowed total repair of the bone defects; Fillerbone and PerioGlass allowed total repair of the defects with intimate contact of the remaining granules and newly formed bone; Bone Source did not allow bone formation with filling of the defects by connective fibrous tissue and the material was almost totally ressorbed.
|
213 |
Avaliação da distorção linear em estruturas métalicas de próteses sobre implantes: fundidas em peça única e em segmentos soldados a laser e através da soldagem convencional (brasagem)Costa, Elza Maria Valadares da [UNESP] 29 June 2001 (has links) (PDF)
Made available in DSpace on 2018-07-27T18:25:55Z (GMT). No. of bitstreams: 0
Previous issue date: 2001-06-29. Added 1 bitstream(s) on 2018-07-27T18:29:54Z : No. of bitstreams: 1
000138043.pdf: 3009336 bytes, checksum: 4461e732807121379a46347a761b1f11 (MD5) / Próteses sobre implantes osseointegrados requerem critério de fabricação preciso devido a ausência de tecidos periodontais que compensam erros menores de relacionamento. Para tanto, em um arco mandibular edêntulo, construído em aço-cromo, foram fixados cinco análogos de pilares de implante, paralelos entre si, com distância de 10mm medidos de centro a centro. Sobre estes foram parafusados novos cilindros de ouro, com torque de 10 N/cm. Então foram executadas 15 sobre-estruturas metálicas que foram divididas: GC - Adaptação passiva dos cilindros de ouro; GM - monobloco GB - segmentos soldados por brasagem e, GL - segmentos soldados a laser. Observou-se as estruturas parafusadas com parafusos sempre novos sob microscópio de mensuração. A medição foi realizada na vestibular e lingual da interface cilindro/análogo e dados anotados em tabela apropriada. Para o eixo y, a técnica de soldagem a laser (Media=12,41 e Dp=11,12) produziu menos distorção significativamente do que a técnica de brasagem (Media=23,06 e Dp=13,31) seguida pela técnica de monobloco (Media=39,83 e Dp=21,88) p= 0.05. Para o eixo x, somente o grupo Monobloco apresentou diferença significativa para as demais técnicas (Média= 45,66 e Dp=21,56) / Prosthesis above osseointegrated implants requires an accurate criterion of manufacture. So, in an edentulous mandibular arch, constructed with chromium steel, five analogous were fixed, parallels, with distance of 10 mm measured of center to center. Above these gold cylinders were positioned and screwed with a torque of 10 N/m. In the next follow, fifteen over structures were fabricated and divided in tour groups: CG - Passive adaptation of gold cylinders; MG - Monobloc casting; BG - Casting in segments after brasing; LG - Casting in segments after laser welding. The structures were observed with measures microscope and the data noted in specific table. The measures done in two points (left and right) in the buccal and lingual surfaces of the interface of the cylinder/analogous set in the x and y-axis. The statistics analysis (ANOVA) showed significant statistics differences, on y-axis, among groups: LG group was superior to BG and this was superior to MG group and on x-axis only MG was superior to others groups (when we studied distortion.)
|
214 |
Análise experimental de copolímero na estabilidade primária de implantes osseointegráveis : avaliação microscópica em ratos /Kayatt, Fernando Esgaib. January 2006 (has links)
Orientador: Idelmo Rangel Garcia Júnior / Banca: Roberta Okamoto / Banca: Luiz Antônio Salata / Banca: Antonio Carlos Guastaldi / Banca: Paulo Sérgio Perri de Carvalho / Resumo: A estabilidade primária na instalação de implantes dentários é uma das determinantes principais no processo de osseointegração. Algumas situações clínicas impossibilitam o travamento adequado do implante. A diástase provocada por sobrefresagem ou implantações pós-exodônticas indicam o uso de materiais para ocupar este espaço. O objetivo deste estudo foi analisar o uso de copolímero a base de ácido poliláctico na estabilidade primária de implantes osseointegráveis, realizando uma avaliação microscópica através de fluorocromos. Para isso, foram utilizados 14 cilindros de Ti cp GII instalados na tíbia de ratos, divididos em: Grupo Implante Travado (GIT) e Grupo Implante e Biomaterial (GIB), nos períodos de 7, 15 e 21 dias. Resultado: Os implantes suportaram 3N.cm de torque reverso e não foram encontradas diferenças estatisticamente significantes, nos períodos finais, entre as médias das áreas ao redor do implante. O copolímero de PLA/PGA proporcionou o posicionamento dos implantes e não obstou a deposição óssea. / Abstract: The primary stability in the installation of dental implants is one of the main prerequisite in the osseointegration process. Some clinical situations disable the adequate stability of the implantation. A gap occurred between the bone and the implant provoked by overdrilling or tooth extractions sockets implantations indicates the use of biomaterials to occupy this space. The aim of this study was to analyze the use of PLA/PGA copolymer in the primary stability of osseointegrated implants, through removal torque test and a microscopic evaluation with fluorescent bone markers. For this, 14 cylinders of Ti cp GII had been installed in the tibia of rats, divided in: Group Implant with Stability (GIT) and Group Implant and Biomaterial (GIB), in the periods of 7, 15 and 21 days. Result: The implantations had supported 3N.cm of removal torque and had not been found differences statistically significant, in the final periods, between the averages of the areas of the periphery of the implants. The PLA/PGA copolymer kept the implants position and did not hinder the bone deposition. / Doutor
|
215 |
Prótese parcial removível de extremidade livre associada a um implante osseointegrado : influência do ligamento periodontal na distribuição interna das tensões /Archangelo, Carlos Marcelo January 2005 (has links)
Resumo: Em função da adoção de hipóteses simplificadoras nos estudos através do método dos elementos finitos (MEF), os dados sobre a menor solicitação das estruturas de suporte na associação da prótese parcial removível de extremidade livre (PPREL) com um implante osseointegrado são inconclusivos. Assim, foi objetivo do presente estudo avaliar, através do MEF bidimensional, a distribuição interna das tensões nas estruturas de suporte da PPREL associada a um implante osseointegrado, em função da reprodução homogênea e não-homogênea do ligamento periodontal (LP). Para isso, 6 modelos (M) foram criados no programa AutoCAD 2005 (Autodesk Inc.; USA), representando: MA - hemiarco contendo somente o dente 33 e o rebordo desdentado para distal; MB - semelhante ao A, com uma PPREL substituindo os dentes ausentes; MC - semelhante ao B, com um implante (Sistema Bränemark - 3,75 mm x 10,0 mm) na região retromolar suportando a base da prótese; MD, ME e MF semelhantes aos modelos A, B e C, respectivamente, com exceção do LP, que foi modelado de forma não-homogênea, com a representação de 4 conjuntos de fibras: fibras da crista, horizontais, oblíquas e apicais. Após isso, os modelos foram exportados para o programa de elementos finitos ANSYS 8.0, e carregados com forças estritamente verticais de 50N em cada ponta de cúspide, fracionadas em 5 pontos de 10N. Os mapas gerais de tensões evidenciaram máxima e mínima concentração de tensões de (em MPa): MA (58,976 e 0,0045); MB (77,863 e 0,0551); MC (207,195 e 0,0057); MD (110,33 e 0,0137); ME (191,36 e 0,0044) e MF (326,60 e 0,0076), com deslocamento máximo de (mm): MA (0,0631); MB (0,1263); MC (0,1142); MD (0,2709); ME (0,1960) e MF (0,2019). (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The application of many hypotheses in a finite element analysis (FEA) has been critical to obtain precise results in the removable partial denture treatment associated with an osseointegrated implant. In view of that, the purpose of the present study was to evaluated, through 2-D finite element analysis, the stress distribution in the support structures of a free-end saddle removable partial denture (RPD) associated with an osseointegrated implant, in function of the homogenous and non-homogenous condition for the periodontal ligament. For this, 6 models (M) were created in the AutoCAD software (Autodesk Inc.; USA), representing: MA - hemiarch contain only the natural tooth (33) and edentulous space in the posterior region; MB - similar to MA, with an RPD replacing the absent teeth; MC - similar to MB, with an osseointegrated implant (Branemark System - 3.75 x 10.00 mm) positioned in a posterior region in order to support the RPD base; MD, ME and MF - identical to MA, MB and MC, respectively; however, in these models, the periodontal ligament was considered an non-homogenous structure by the incorporation of four fibers groups in a sagital plane: alveolar crest fibers, horizontals, oblique, and apical fibers. After this, the models were exported to the finite element program (ANSYS 8.0) and loaded with verticals forces (50N) in each cusp. The results showed maximum and minimum stress (MPa): MA (58.976 and 0.0045); MB (77.863 and 0.0551); MC (207.195 and 0.0057); MD (110.33 and 0.0137); ME (191.36 and 0.0044) and MF (326.60 and 0.0076). The maximum displacement (mm) was: MA (0.0631); MB (0.1263); MC (0.1142); MD (0.2709); ME (0.2019) and MF (0.2019). (Complete abstract click eletronic address below) / Orientador: Eduardo Passos Rocha / Coorientador: João Antônio Pereira / Banca: Eduardo Piza Pellizzer / Banca: Wellington Cardoso Bonachela / Banca: Eduardo Passos Rocha / Mestre
|
216 |
Reação tecidual à superfície de titânio tratada pela irradiação laser e hidroxiapatita : análise histomorfométrica em ratos /Lacoski, Marcelo Kayatt. January 2005 (has links)
Orientador: Roberta Okamoto / Banca: Luis Eduardo Marques Padovan / Banca: Idelmo Rangel Garcia Júnior / Resumo: O tratamento de superfície dos implantes está consolidado como um método capaz de acelerar e melhorar a qualidade da osseointegração, possibilitando técnicas de carregamento precoce dos implantes, diminuindo o tempo de tratamento e o número de insucessos. Desta forma, o objetivo deste estudo foi observar o comportamento celular do tecido subcutâneo de ratos submetidos a implantes de discos de titânio tratados com laser e laser e hidroxiapatita. Para isso, foram utilizados 32 discos de Ti cp implantados no tecido subcutâneo da região dorsal anterior e posterior de 16 animais (Rattus norvegicus albinus, Wistar), divididos em 2 grupos: LA - discos tratados com irradiação laser e LHA - discos tratados com irradiação laser e deposição de hidroxiapatita pelo método biomimético. Na análise histológica pôde-se observar que houve formação conjuntiva na periferia das amostras de titânio, com espessura e presença celular semelhantes, em ambos os grupos. Qualitativamente, o grupo LHA mostrou melhor organização tecidual nos tempos iniciais. Na análise morfométrica houve diferença estatisticamente significante entre os grupos, para a>0,01. / Abstract: The treatment of surface of the dental implants is consolidated as a method capable to speed up and to improve the quality of the osseointegration, making possible precocious shipment techniques of the implantations, decreasing the time of treatment and the number of failures. Of this form, the aim of this study was to observe the cellular behavior of the subcutaneous tissue submitted to titanium implantations treated with laser and laser with hydroxyapatite. For this, 32 test implants of grade-I commercially pure titanium had been inserted in the connective tissue of the dorsal region of 16 male rats (Rattus norvegicus albinus, Wistar), divided in 2 groups: LA - test implants treated with laser irradiation and LHA - test implants treated with laser irradiation and deposition of hydroxyapatite by the biomimethic method. In the histological analysis it could be observed that it had conjunctive formation in the periphery of the titanium samples, with thickness and similar cellular presence, in both groups. Qualitatively, the group LHA better showed tissue organization in the initial times. There was statistic significant difference between the groups, of the measure of the thickness of the fibrous connective tissue formed in contact with tested implants, for a>0,01. / Mestre
|
217 |
Análise física química e mecânica de um cimento experimental à base de MTAMassi, Santiago [UNESP] 31 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:45Z (GMT). No. of bitstreams: 0
Previous issue date: 2010-03-31Bitstream added on 2014-06-13T18:56:26Z : No. of bitstreams: 1
massi_s_me_arafo.pdf: 223224 bytes, checksum: 277dcea4e6af26233b5a8ab30ff054dd (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Modificações têm sido propostas ao MTA e cimento Portland para a obtenção de um cimento obturador de canal radicular. Um material experimental à base de MTA (CE-MTA) é avaliado neste estudo para emprego como cimento endodôntico, contendo cimento Portland, radiopacificador, aditivos e veículo. Assim, o objetivo deste estudo foi avaliar o cimento experimental, usando como parâmetros comparativos o cimento AHPlus (AHP), MTA-Angelus (MTA) e cimento Portland (CP). Foram realizados testes de tempo de presa; resistência à compressão; escoamento; radiopacidade; alteração do pH e liberação de íons cálcio. Todas as metodologias foram definidas usando como referência normas ISO e a literatura científica recente da área endodôntica. O teste de escoamento seguiu a metodologia proposta pela norma ISO, com a medição do diâmetro dos discos de cimento, assim como da área por meio de um programa de imagens. O tempo de presa foi avaliado pela norma da ADA/ASTM, verificando os períodos de tempo necessários para que as agulhas indentadoras (100g e 2mm de diâmetro na ponta; e 456g e 1 mm de diâmetro na ponta) não marcassem a superfície dos discos de cimento, fornecendo resultados para a presa inicial e final. No teste de radiopacidade foi feita uma comparação da radiopacidade de discos de cimento de 10mm de diâmetro e 1 mm de espessura, com uma escala de alumínio padronizada. A alteração de pH do foi avaliada com um pHmetro e a liberação de cálcio com um espectrofotômetro de absorção atômica. Para ambos os ensaios tubos preenchidos com o cimento foram imersos em frascos contendo água destilada. Os tubos foram passados para um novo frasco contendo mais água destilada nos períodos de tempo de 3, 6, 12, 24 e 48 horas, assim como 7, 14 e 28 dias. O líquido remanescente nos frascos foi avaliado para obter os resultados deste ensaio. Na resistência à compressão... / Modifications of MTA and Portland cement has been proposed to obtain an root canal sealer. This study evaluates an experimental MTA based root canal sealer (CE-MTA) which contains Portland cement, radiopacifier, addictives and a vehicle. The aim of this study was to evaluate the experimental endodontic sealer, using white Portland cement (CP), MTAAngelus(MTA) and AH Plus (AHP) as control groups. The tests realized were: setting time, radipacity, compressive strength, pH alterations, calcium release and flow. The flow test followed the ISO 6876 norms, and the the sealer discs’ area was measured with a paquimeter and using an area measurement software. The setting time was measured based on the ADA/ASTM Norm, allowing initial and final setting time measurements. Radiopacity was measured using an aluminum scale as reference and sealer discs with 10 mm in diameter by 1 mm thick. The pH was measured using a pHmeter and the calcium release using an atomic absorption spectrophotometer. For compressive strength test the ISO 9917 methodology was used, testing specimens at 24 hours and 21 days. All the data was submitted to statistical analysis, a normality test, and after the data normality check, an ANOVA and a Tukey test using 5% significance were applyed. Results: The results showed that CE-MTA has flow similar to AH Plus and superior to the minimum required by the ISO standard. The setting time was faster than AH Plus and slower than MTA and Portland cement. The compressive strength was lower for the experimental sealer at 24 hours time compared with all the tested materials, and similar for the experimental sealer and MTA at 21 days. The experimental sealer had a superior calcium release in all period of time, and higher pH values until 48 hours period, being similar to MTA and Portland cement on posterior time periods. The experimental sealer radiopacity was lower... (Complete abstract click electronic access below)
|
218 |
Avaliação de materiais restauradores ionoméricos, empregando a técnica do ARTFernandes, Adriana Beatriz Silveira Pinto [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:45Z (GMT). No. of bitstreams: 0
Previous issue date: 2004Bitstream added on 2014-06-13T20:36:13Z : No. of bitstreams: 1
fernandes_absp_me_araca.pdf: 2346845 bytes, checksum: f5101690e1608a466dec96035c51358b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação para o Desenvolvimento da UNESP (FUNDUNESP) / Este estudo teve como objetivo avaliar a interação dos materiais ionoméricos com a dentina, na remoção do tecido cariado, empregando a técnica convencional e a do ART. De um total de 109 dentes, 13 ficaram para controle, 48 foram preparados pela técnica convencional, G I, e os outros 48 pela técnica do ART, G II. Após o preparo das cavidades, os espécimes foram aleatoriamente divididos em 03 subgrupos de acordo com o material restaurador ionomérico empregado: KETAC FILL para G I 1 e G II 1, VIDRION R para G I 2 e G II 2 e FUJI II LC para G I 3 e G II 3, todos com 16 dentes em cada subgrupo. Em cada subgrupo experimental, 06 dentes foram avaliados macroscopicamente e os outros 10, microscopicamente. Para a análise macroscópica, a parte radicular de 36 espécimes restaurados e de 03 espécimes controle foi incluída em resina, e o dente cortado em fatias. Cada fatia foi analisada em lupa estereoscópica a um aumento de 60 vezes. Para a análise microscópica, os 60 dentes preparados e os outros 10 cariados foram descalcificados em solução de EDTA, desidratados e submetidos a banhos de parafina, cortados a uma espessura de 6 micrometros, corados pelo método de Brown & Brenn, e avaliados em microscopia óptica. Os resultados na macroscopia revelaram uma boa adaptação dos materiais à superfície dentinária, pós remoção do tecido cariado; sugerindo semelhança de comportamento quando considerada a técnica de remoção de dentina cariada: convencional e ART. Quando considerado os materiais ionoméricos a avaliação da interface demonstrou um melhor comportamento dos ionômeros FUJI II LC e KETAC FILL em relação ao VIDRION R. Na análise microscópica somente com o FUJI II LC foi possível observar interação do material com a estrutura dentinária, revelando ainda supremacia de comportamento quando se utilizou a técnica convencional em relação a técnica do ART. / This study evaluated the interaction between glass ionomer materials and dentine using the convencional technique and ART in the remotion of decayed tissue. One hundred and nine teeth were used, 13 as control, 48 prepared by the conventional technique (group I) and the other 48 by ART technique (group II). After preparation of the cavites, the specimens were divided in 3 subgroups according to the glass ionomer material used: KETAC FILL for groups G I 1 and G II 1, VIDRION R for groups G I 2 and G II 2 and FUJI II LC for groups G I 3 and G II 3, all with 16 teeth in each subgroup. In each experimental subgroup, 6 teeth were evaluated macroscopically and the other 10, microscopically. For the macroscopic analysis, the root of 36 restored specimens and 3 control specimens were included in resin and the tooth was divided in slices. Each slice was analyzed in a stereoscopic magnifying glass at 60 times magnifying power. For the macroscopic analysis, the 60 prepared teeth and the other 10 decayed ones were decalcified in EDTA solution, dehydrated and subjected to parafine baths, cutt with 6 μm thickness, stained by the Brown & Brenn method, and evaluated in a light microscope. The results of the macroscopic analysis showed a good adaptation of the materials to dentine surface, after remotion of decayed tissue, suggesting similarity of behavior when considering the technique of decayed dentine remotion: conventional and ART. When considering ionomer materials, the evaluation of the interface showed a better behavior of FUJI II LC and KETAC FILL in comparison to VIDRION R. In the microscopic analysis, it was possible to observe the interaction between the material and dentine structure only with FUJI II LC, showing the supremacy of behavior when using the conventional technique in comparison to ART technique.
|
219 |
Técnica do tratamento restaurador atraumático convencional e modificado em molares decíduos: avaliação clínica de 12 mesesSilva, Janaína Zavitoski [UNESP] 20 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:47Z (GMT). No. of bitstreams: 0
Previous issue date: 2006-12-20Bitstream added on 2014-06-13T19:56:37Z : No. of bitstreams: 1
silva_jz_me_araca.pdf: 3111361 bytes, checksum: 74570a52c22b3ad6383e9164ec8da4a1 (MD5) / O presente trabalho avaliou clinicamente a performance de restaurações Classe I realizadas em molares decíduos pelas técnicas restauradoras atraumáticas convencional (TRA) e modificada (TRA Mod). Foram realizadas 46 restaurações pela técnica do TRA, empregando-se como material restaurador o cimento de ionômero de vidro Ketac Molar Easy Mix (3M, ESPE, Seefelf, Germany) e 57 restaurações pela técnica do TRA Modificado, utilizando-se o ionômero de vidro modificado por resina Fuji II LC (GC Corporation, Tokyo, Japan). As restaurações foram avaliadas após 24 horas, 3, 6 e 12 meses de acordo com a ocorrência de sensibilidade pós-operatória, desempenho clínico e ocorrência de lesões cariosas. Os dados foram analisados transversal e longitudinalmente com a aplicação dos testes de Mann-Whitney e Friedman, respectivamente. A análise transversal mostrou não haver diferença estatisticamente significante entre as técnicas restauradoras em todos os itens avaliados. Da mesma forma, a análise longitudinal revelou semelhança entre os períodos de avaliação para a sensibilidade pós-operatória e ocorrência de lesões cariosas em ambas as técnicas. Todavia, observou-se diferença estatisticamente significante no desempenho clínico das restaurações nos períodos de 3 e 12 meses, assim como aos 6 e 12 meses para técnica do TRA. Nas restaurações realizadas pela técnica do TRA Mod, observou-se diferença entre os períodos de 3 e 12 meses. Concluiu-se que a sensibilidade pós-operatória foi pouco freqüente e semelhante para ambas as técnicas restauradoras e tende a ocorrer nos períodos iniciais pósrestauração. As técnicas restauradoras apresentaram desempenho clínico semelhante em todos os períodos avaliados, destacando-se que as restaurações realizadas pela técnica do TRA mostraram queda em seu desempenho clínico após 6 meses de acompanhamento e para a técnica do TRA Mod aos 12 meses. / This study has evaluated clinically the performance of Class I restorations in primary molars by the atraumatic restorative treatment conventional techniques and modified. Forty-six restorations have been done by the ART technique, using as restorative material the GIC Ketac Molar Easy Mix (3M, ESPE, Seefelf, Germany) and 57 restorations by the ART modified technique, using resin-modified glass ionomer (RMGI) Fuji II LC (GC Corporation, Tokyo, Japan.) The restorations have been evaluated after 24 hours, 3, 6 and 12 months according to the post-surgery sensibility occurrence, clinical performance and carious lesions occurrence. Data have been analyzed transversal and longitudinal with Mann-Whitney and Friedman, respectively. The transversal analysis showed no significant difference among the restorative techniques and all other evaluated items. Furthermore, longitudinal analysis showed some similarities between the evaluation periods for post-surgery sensibility and carious lesions occurrences in both techniques. Nevertheless, a significant difference in the clinical performance of restorations in the periods of 3 and 12 months has been noticed, just like 6 and 12 months period for the ART Modified technique, a difference in the period of 3 and 12 months has been noticed. To come to a conclusion the post-surgery sensibility was little frequent and similar for both restorative techniques and that occurs in the first post-surgery periods. Restorative techniques present similar performance in all evaluation periods, highlighting that restorations performed by the ART technique declines after 6 months and for the ART modified in the 12 months. The occurrence of decay lesions on restored teeth was little frenquent and similar for both restoration techniques.
|
220 |
Osseointegração de implantes porosos de titânio submetidos ao tratamento biomiméticoLeite, Daniel de Oliveira [UNESP] 04 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:56Z (GMT). No. of bitstreams: 0
Previous issue date: 2011-07-04Bitstream added on 2014-06-13T19:07:01Z : No. of bitstreams: 1
leite_do_me_sjc.pdf: 1900318 bytes, checksum: 493844aa6951b9fcb70dcecafae54a38 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Atualmente, as pesquisas em Implantodontia enfatizam modificações na superfície dos implantes, visando melhorar a osseointegração. Nesse sentido, o presente estudo teve como objetivo avaliar a influência da porosidade, bem como do tratamento biomimético (TB), na osteogênese in vivo em implantes de titânio. Foram confeccionados, por meio da metalurgia do pó, implantes de titânio puro grau 2, que foram divididos em seis grupos: a) G1: denso; b) G2: 40% de porosidade; c) G3: 50% de porosidade; d) G4: G1 + TB; e) G5: G2 + TB; f) G6: G3 + TB. Inicialmente, as amostras foram caracterizadas por análise metalográfica e por espectroscopia por energia dispersiva (EDS). Em seguida, os implantes foram inseridos nas tíbias de dezesseis coelhos da raça Nova Zelândia, para avaliar a reparação óssea peri-implantar, por meio de análise histológica e histomorfométrica. Como padronização, os implantes G1, G2 e G3 foram inseridos na tíbia direita e G4, G5 e G6 na esquerda. Quatro coelhos, selecionados aleatoriamente, foram submetidos à eutanásia, 01, 02, 04 e 08 semanas após a cirurgia. Os dados da análise metalográfica foram submetidos ao teste de Kruskal-Wallis e a análise histomorfométrica foi avaliada pelos testes ANOVA e Tukey. Os resultados da metalografia confirmaram porosidade de 40 e 50%, e revelaram poros com tamanho médio de 370 μm e interconexão entre os mesmos. Na análise por EDS foi observada a presença de íons Ca e P, caracterizando o sucesso do TB. Na análise histológica observou-se neoformação óssea, inclusive para o interior dos poros, independente do tipo de implante ou do tempo. Na análise histomorfométrica, verificou-se maior neoformação óssea em G5 e G6, e menor em G1, sendo que ambas as condições mostraram diferença estaticamente significante em relação aos demais grupos. Concluiu-se que o TB associado à porosidade exerce influência positiva na neoformação óssea. / Researches in implantodontology have been recently focusing on implant surface modifications aiming to improve osseointegration. Thus, the purpose of the present study was to evaluate in vivo the influence of titanium implants surface porosity and surface biomimetic treatment (BT) on osteogenesis. Grade 2 pure titanium implants were fabricated by means of powder metallurgy and divided into six groups: a) G1: dense; b) G2: porosity of 40%; c) G3: porosity of 50%; d) G4: G1 + BT; e) G5: G2 + BT; and f) G6: G3 + BT. The samples were initially characterized by metallographic analysis and energy-dispersive spectroscopy (EDS). The implants were then placed into the tibia of sixteen New Zealand rabbits in order to evaluate the peri-implant bone repair by means of histological and histomorphometric analyses. As standardization, implants from groups G1, G2 and G3 were inserted into right tibias; while G4, G5 and G6 into left ones. Four randomly chosen rabbits underwent euthanasia 01, 02, 04 and 8 weeks after surgery. The results from metallographic analysis were analyzed by Kruskal-Wallis test and the histomorphometric results by ANOVA and Tukey tests. Metallographic results confirmed porosity between 40 and 50%, and revealed mean pore size of 370 μm and interconnection among them. EDS analysis detected the presence of Ca and P ions, confirming BT success. Bone neoformation, including into the pores, was detected by the histological analysis regardless the type of implant or evaluated period. By the histomorphometric analysis, bone neoformation was statistically greater for G5 and G6 and statistically lesser for G1 in comparison to the other groups. It was concluded that BT associated with porosity exerts positive influence on bone neoformation.
|
Page generated in 0.0501 seconds