• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1119
  • 279
  • 52
  • 21
  • 18
  • 18
  • 18
  • 14
  • 6
  • 4
  • 3
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 1477
  • 532
  • 204
  • 194
  • 152
  • 145
  • 145
  • 145
  • 145
  • 145
  • 143
  • 141
  • 136
  • 132
  • 100
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Produção de Nanopartículas de Dióxido de Titânio com Características Janus para Uso em Dispositivos Fotovoltaicos Orgânicos

Lima, Thaíses Brunelle Santana de 31 January 2014 (has links)
Submitted by Etelvina Domingos (etelvina.domingos@ufpe.br) on 2015-03-12T18:05:01Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO Thaises Brunelle de Lima.pdf: 2138377 bytes, checksum: 3d7f6e7b30968db5465114bb99e5b693 (MD5) / Made available in DSpace on 2015-03-12T18:05:01Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO Thaises Brunelle de Lima.pdf: 2138377 bytes, checksum: 3d7f6e7b30968db5465114bb99e5b693 (MD5) Previous issue date: 2014 / CNPq / Partículas com caráter Janus são aquelas que apresentam características distintas em cada um de seus hemisférios. Esse tipo de partículas tem atraído muita atenção em áreas de pesquisas diversas. Neste trabalho preparamos nanopartículas de dióxido de titânio (TiO2) com característica Janus através de um método simples, chamado método de emulsão de Pickering. Estas partículas foram caracterizadas através de microscopia eletrônica de varredura. Como aplicação destas partículas, elas foram utilizadas em dispositivos fotovoltaicos orgânicos de heterojunção de volume, que consiste em uma camada ativa de materiais interpenetrados e colocados entre os eletrodos. A camada ativa era composta pelo polímero condutor Poli (1 - metoxi-4-(2-etil-hexiloxi)-p-fenilenovinileno) (MEHPPV), que funciona como doador de elétrons, e nanotubos de carbono de múltiplas camadas (MWCNT) foram usados como aceitadores de elétrons. Os dispositivos preparados foram analisados através da caracterização elétrica, onde realizamos medidas de fotocondutividade com o intuito de comparar os sistemas com camada ativa pura, com adição de nanopartículas de TiO2 e com adição das nanopartículas de TiO2 com características Janus.
142

Sistema intra-uterino liberador de levonorgestrel no controle da dor pelvica em mulheres com endometriose

Bassalobre, Daniela Fink Hassan 25 October 2005 (has links)
Orientador: Carlos Alberto Petta / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-05T06:27:02Z (GMT). No. of bitstreams: 1 Bassalobre_DanielaFinkHassan_D.pdf: 5592791 bytes, checksum: 3336aac57873e42c83ea3ff5b0771ffa (MD5) Previous issue date: 2005 / Resumo: O objetivo deste estudo multicêntrico randomizado controlado foi comparar a eficácia do Sistema Intra-uterino liberador de Levonorgestrel (Mirena®) em relação ao análogo do GnRH no controle da dor pélvica em mulheres com endometriose, durante o período de seis meses. Oitenta e duas mulheres com idade entre 18 e 40 anos (média de 30 anos), com diagnóstico de endometriose e dor pélvica crônica e/ ou dismenorréia foram selecionadas no período de fevereiro de 2002 a maio de 2004 no Ambulatório de Endometriose de três respectivos centros: CAISM-Unicamp, FMUSP-RP, FMUSP-SP. As participantes foram alocadas através de um esquema de randomização gerado por computador, em envelopes opacos e selados, admitidas por ordem de entrada na pesquisa, totalizando 39 usuárias do Sistema Intra-uterino liberador de Levonorgestrel e 43 do grupo-controle em uso do análogo do GnRH. Foram avaliadas a dor pélvica crônica e/ ou dismenorréia através de Escala Visual Analógica de Dor, sendo determinados os escores diários de dor durante o seguimento e a cada visita mensal. O escore de dor em cada visita foi baseado na ocorrência e intensidade da dor, medida através da Escal Visual Analógica de Dor no momento da consulta, enquanto o escore mensal foi calculado através da somatória dos escores diários de dor divididos pelo número de dias do período observado. O padrão menstrual foi avaliado pelo escore diário de sangramento e a qualidade de vida analisada através da aplicação do questionário de avaliação do Índice Psicológico de Bem-Estar Geral, no início e no término do estudo. A análise estatística inicial consistiu na comparação de diversas características das mulheres da amostra, entre os grupos de tratamento. Posteriormente, para a análise da variável quantitativa contínua com distribuição normal utilizou-se o teste paramétrico t de Student, e nas variáveis quantitativas contínuas sem distribuição normal foi aplicado o teste não paramétrico de Mann-Whitney. Para as variáveis qualitativas realizou-se o teste qui-quadrado ou exato de Fisher. Para as variáveis dependentes com escore numérico aplicou-se a análise de variância com medidas repetidas (MANOVA) e, em seguida, foram apresentadas as comparações entre os grupos de tratamento utilizando o teste não paramétrico de Mann-Whitney. Os resultados mostraram que as mulheres dos dois grupos de tratamento apresentaram um decréscimo significativo da dor pélvica já no primeiro mês de seguimento e ao final de seis meses; entretanto, quando comparados os grupos, não se observaram diferenças quanto à redução do escore de dor (p>0,999). As usuárias do análogo e do Sistema Intra-uterino liberador de Levonorgestrel, com endometriose estádios III e IV, apresentaram ao longo do tempo um decréscimo mais rápido e significativo no escore de dor que as mulheres com estádios I e II durante o seguimento (p<0,002). O padrão menstrual predominante foi amenorréia, presente no primeiro mês em 34% das usuárias do Mirena® e em 71% das usuárias do análogo do GnRH e, ao final de seis meses, em 70% e 98% respectivamente (p<0,001). Não houve diferenças quanto à mudança da qualidade de vida das mulheres da amostra. Concluiu-se, assim, que o uso do Sistema Intra-uterino Liberador de Levonorgestrel é tão eficaz no controle da dor pélvica em endometriose quanto o análogo do GnRH, devendo ressaltar-se a vantagem de tratar-se de uma medicação de duração de cinco anos, com poucos efeitos colaterais, não induzindo ao hipoestrogenismo persistente, ao contrário do tratamento clássico / Abstract: The objective of this randomized controlled clinical trial was to compare the efficacy of a Levonorgestrel-releasing Intrauterine System and a depot GnRH analogue in the control of endometriosis-related pain over a period of six months. Eighty-two women, aged 18 to 40 (mean 30), with endometriosis, dysmenorrhea and/or chronic pelvic pain, were randomized using a computer-generated system of sealed envelopes into either Levonorgestrel-releasing Intrauterine System (n=39) or GnRH analogue (n=43) treatment groups at three University centres. Daily scores of endometriosis-associated chronic pelvic pain were evaluated using the Visual Analogue Scale, daily bleeding score was calculated from bleeding calendars, and improvement in quality of life was evaluated using the Psychological General Well-Being Index Questionnaire (PGWBI) were evaluated. The pain score diary was based on the Visual Analogue Scale in which women daily recorded the occurrence and intensity of the pain on a daily basis. A monthly score was calculated from the result of the sum of the daily scores divided by the number of days in each observation period. Chronic pelvic pain decreased significantly from the first month throughout the six months of therapy with both forms of treatment and there was no difference between the groups (p > 0.999). In both treatment groups, women with stage III and IV endometriosis showed a more rapid improvement in the Visual Analogue Scale pain score than women with stage I and II (p < 0.002). Levonorgestrel-releasing Intrauterine System users had a higher bleeding score than GnRH-analogue users at all time points of observation with 34% and 71% of patients in the Levonorgestrel-releaisng Intrauterine System and GnRH- analogue groups respectively; reporting no bleeding during the first treatment month, and 70% and 98% reporting no bleeding during the sixth month. No difference was observed between groups with reference to improvement in quality of life. Both, the Levonorgestrel-releasing Intrauterine System and the GnRH-analogue were effective in the treatment of chronic pelvic pain associated endometriosis, although no differences were observed between two treatments. Among the additional advantages of the Levonorgestrel-releaisng Intrauterine System is the fact that it does not provoke hypoestrogenism and that it requires only one medical intervention for its introduction every five years. The device could therefore become the treatment of choice for chronic pelvic pain associated endometriosis in women who do not wish to conceive / Doutorado / Tocoginecologia / Doutor em Tocoginecologia
143

Quimiocinas endometriais, celulas natural killer uterinas e mastocitos em usuarias do sistema intra-uterino liberador de levonorgestrel com e sem sangramento uterino no terceiro ano de uso

Pinto, Alessandra Cachute Peloggia 04 October 2006 (has links)
Orientador: Carlos Alberto Petta / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-06T11:01:44Z (GMT). No. of bitstreams: 1 Pinto_AlessandraCachutePeloggia_D.pdf: 1211304 bytes, checksum: 68153a393e793af5d893cd7402ea8641 (MD5) Previous issue date: 2006 / Resumo: As alterações no padrão de sangramento são praticamente universais em usuárias de métodos contraceptivos contendo somente progestógenos, sendo uma importante causa de descontinuação destes métodos. Este estudo foi desenvolvido com o intuito de se avaliar as quimiocinas Interleucina 8 e 6 CKine no endométrio de usuárias do sistema intra-uterino liberador de levonorgestrel e correlacioná-las com as populações de leucócitos, células natural killer uterinas e mastócitos. Amostras de endométrio foram obtidas de dois grupos de usuárias do sistema intra-uterino liberador de levonorgestrel: 11 mulheres em amenorréia e 15 mulheres com algum tipo de sangramento. Os leucócitos foram determinados através de anticorpos específicos para neutrófilos, células natural killer uterinas e mastócitos. Foi realizada imuno-histoquimica para identificação das quimiocinas. Os neutrófilos encontravam-se em pequeno número, não havendo diferença entre os dois grupos. As células natural killer uterinas encontravam-se em número maior no grupo com sangramento (p<0,0001). Não houve diferença entre o número total de mastócitos e mastócitos ativados, porém houve um aumento da área extracelular positiva para triptase (p<0,05) nas mulheres com sangramento. As quimiocinas Interleucina-8 e 6CKine mostravam-se abundantes no estroma e no epitélio, não havendo diferença entre os dois grupos. Houve maior número de células natural killer uterinas e maior área extracelular positiva para triptase em pacientes que apresentavam sangramento. Apesar de não haver diferença entre o número total de mastócitos e mastócitos ativados e das quimiocinas Interleucina-8 e 6CKine, as células natural killer uterinas e os produtos dos mastócitos podem ter exercido papel importante na perda da integridade endometrial em usuárias do sistema intra-uterino de levonorgestrel / Abstract: Changes in the bleeding pattern are almost universal in women using progestin-only methods of contraception, and are a frequent cause of discontinuation of these methods. The present study was designed to assess endometrial chemokines in users of the Levonorgestrel intrauterine system and correlate them with leukocyte populations, uterine natural killer cells, and mast cells. Endometrium was obtained from two groups of Levonorgestrel intrauterine users: 11 amenorrhoeic women and 15 women with some form of bleeding pattern. Leukocytes were assessed using specific antibodies for neutrophils, uterine natural killer cells and mast cells. Immunohistochemistry was performed to locate chemokines 6Ckine and Interleukin-8. Neutrophils were few and without differences between the two groups. Uterine natural killer cells were significantly higher in the bleeding group (p< 0.0001). There was no difference between the total number of mast cells and activated mast cells but there was a greater extracellular area stained for mast cell tryptase (p<0.05) in women with bleeding. Chemokines 6CKine and Interleukin-8 were abundant in the stroma and in the epithelium and there was no difference between the groups. We observed more uterine natural killer cells in users with bleeding, and a greater extracellular area stained for mast cell tryptase, although there were no differences between the number of mast cells and activated mast cells or the chemokines 6CKine and Interleukin-8. Uterine natural killer cells and mast cells products may play a role in provoking break-through bleeding in long term users of the levonorgestrel intrauterine system / Doutorado / Tocoginecologia / Doutor em Tocoginecologia
144

Sensor Hall de GaAs por implantação de ions

Maricato, Efeso Francisco de Melo 18 December 2000 (has links)
Orientador: Jacobus W. Swart / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-28T13:25:30Z (GMT). No. of bitstreams: 1 Maricato_EfesoFranciscodeMelo_M.pdf: 5710050 bytes, checksum: 922d33a93b7944d93f66aff4dde18594 (MD5) Previous issue date: 2000 / Resumo: Neste trabalho projetamos, fabricamos e caracterizamos sensores magnéticos de efeito Hall. Realizamos um estudo sobre os princípios físicos envolvidos e figuras de mérito dos sensores (Tensão Hall, Sensibilidade, Tensão offset, Linearidade, Ruído e Coeficiente de temperatura) e, então, projetamos sensores Hall de várias geometrias, obtendo dispositivos com diferentes sensibilidades. Fabricamos estes dispositivos em camadas ativas de diferentes espessuras e dopagens com o objetivo de estudar o efeito destas variáveis na sensibilidades e linearidade dos dispositivos. O processo de fabricação desenvolvido é compatível com o processo de fabricação de transistores MESFET. Após o projeto dos sensores e processo de fabricação, fabricamos 5 níveis de máscaras através de um equipamento de feixe de elétrons. As camadas ativas foram obtidas por duas diferentes técnicas: implantação de íons e crescimento epitaxial. As regiões ativas implantadas foram dopadas com íons de 'SI POT. + SOB. 29¿ e a camada epitaxial dopada com silício, de modo que a concentração de portadores na camada ficasse na ordem de 1,0 x ¿10 POT. 17¿ 'CM POT. 3¿ e a espessura entre 0,2 - 0,5 'MU¿m. Após o encapsulamento dos dispositivos, caracterizamos os sensores com polarização de 1 - 7 mA e indução magnética entre O - 1,2 T (tesla). Os sensores fabricados apresentaram alta sensibilidade (88 - 820 V/A.T), tensão offset esperada e alta linearidade. Propomos alguns estudos sobre melhorias do processo de fabricação e sobre circuitos de condicionamento de sinais. ...Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: In this work we designed, fabricated and characterized Hall-effect magnetic sensors. We studied the involved physical principies and figures of merit of sensors (Hali voltage, Sensitivity, Offset voltage, Linearity, Noise and Temperature coefficient) and, then, we designed Hall sensors of different shapes, obtaining devices with different sensitivities. We fabricated these devices in active layers of different thicknesses and doping levels with the objective to study the effect of these variables on the sensitivity and linearity of the devices. The developed process is compatible with the fabrication process of MESFET transistors. After the design of the sensorsand the process,we fabricateda set of 5 levels of masks through an electron-beam equipment. The active layers have been obtained by two different techniques: ion implantation and epitaxial growth. The implanted active regions have been doped with ions of 'SI POT. + SOB. 29¿ and the doped epitaxial layer with silicon, so that the concentration of carriers in the layer was of the order of 1,0 x ¿10 POT. 17¿¿CM POT. 3¿ and the thickness between 0.2 - 0.5 'MU¿m.After the packaging of the devices, we characterized the sensors with current bias of 1 - 7 mA and magnetic induction between O - 1.2 T (tesla).The fabricated Hall sensors presented high sensitivity (88 - 820 V/A.T), low offset voltage and high linearity. Based on the results, some additional studies on improvements on the fabrication process and the signal conditioning circuits are suggested. ...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Mestre em Engenharia Elétrica
145

CARACTERIZA??O DE FSS COM GEOMETRIA EM FORMA DE ESTRELA DE QUATRO BRA?OS

LIMA, Isaac Silva Sousa 07 1900 (has links)
Submitted by Alex Sandro R?go (alex@ifpb.edu.br) on 2016-09-01T13:10:13Z No. of bitstreams: 1 CARACTERIZA??O DE FSS COM GEOMETRIA EM FORMA DE ESTRELA DE QUATRO BRA?OS.pdf: 17969955 bytes, checksum: a291b0138a771d13c9b2960bbc2cba98 (MD5) / Approved for entry into archive by Alex Sandro R?go (alex@ifpb.edu.br) on 2016-09-01T13:10:38Z (GMT) No. of bitstreams: 1 CARACTERIZA??O DE FSS COM GEOMETRIA EM FORMA DE ESTRELA DE QUATRO BRA?OS.pdf: 17969955 bytes, checksum: a291b0138a771d13c9b2960bbc2cba98 (MD5) / Made available in DSpace on 2016-09-01T13:10:38Z (GMT). No. of bitstreams: 1 CARACTERIZA??O DE FSS COM GEOMETRIA EM FORMA DE ESTRELA DE QUATRO BRA?OS.pdf: 17969955 bytes, checksum: a291b0138a771d13c9b2960bbc2cba98 (MD5) Previous issue date: 2014-07 / O aumento da procura por dispositivos de comunica??o m?veis com capacidade de transmiss?o elevada e com dimens?es reduzidas, tem levado engenheiros de telecomunica??es e micro-ondas a realizarem trabalhos e pesquisas constantes na busca por novas tecnologias capazes de suprir essas demandas. T?cnicas de miniaturiza??o e emprego de sistemas de antenas inteligentes s?o algumas das alternativas mais comuns nesse processo. Recentemente, alguns grupos de pesquisa v?m estudando a efici?ncia das superf?cies seletivas em frequ?ncia (FSS) nesse tipo de sistema. Nesse contexto esse trabalho prop?e a apresentar uma nova geometria para fabrica??o de FSS. Definida como geometria estrela de quatro bra?os, a estrutura proposta apresenta caracter?sticas de miniaturiza??o e comuta??o. O documento apresenta o problema que motivou o desenvolvimento do projeto, assim como conceitos e defini??es sobre FSS, suas principais caracter?sticas, t?cnicas de an?lises e medi??es e aplica??es mais comuns. O texto traz ainda a formula??o te?rica do m?todo das ondas (WCIP) aplicado na an?lise de FSS. Esse m?todo num?rico tem a capacidade de determinar o comportamento da onda eletromagn?tica ao incidir sobre uma FSS e vem sendo estudado pelo GTEMA - IFPB como base te?rica do software desenvolvido pelo grupo, o WCIP08. A geometria estrela de quatro bra?os ? apresentada em sua forma sim?trica e assim?trica, e suas respectivas varia??es. Cada estrutura foi caracterizada numericamente, em seguida foram constru?dos prot?tipos para caracteriza??o experimental. Por fim os resultados foram comparados e constatou-se uma boa concord?ncia entre eles. Al?m disso, os testes confirmaram a efici?ncia da geometria em estudo para poss?veis aplica??es em sistemas de comunica??o que necessitem de
146

Avaliação do comprimento da cavidade uterina por meio da histerometria e ultrassom em mulheres nuligestas e com gestação previa / Lenght of theendometrial cavity as measured by uterine sounding andultrasonography in women of different parities

Canteiro, Renata 12 November 2009 (has links)
Orientador: Luis Guillermo Bahamondes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-14T21:06:45Z (GMT). No. of bitstreams: 1 Canteiro_Renata_M.pdf: 1520573 bytes, checksum: 430ed31c6f7893af060873188cd2b55a (MD5) Previous issue date: 2009 / Resumo: Introdução e objetivos: O dispositivo intrauterino (DIU), apesar de ser um método contraceptivo altamente eficaz e adequado para a maioria das mulheres, nem sempre é recomendado para mulheres nuligestas. Alguns artigos apontaram para taxas de expulsão e gravidez aumentadas neste grupo de mulheres e outros sugeriram a adoção de DIU menores para nuligestas. Esta discussão tem se tornado mais evidente devido ao grande número de gravidezes indesejadas entre adolescentes (as quais, em sua maioria, são nuligestas), evidenciando a necessidade de métodos contraceptivos adequados a este perfil de usuárias. Restam dúvidas sobre a necessidade de novos DIU menores ou de formatos diferentes. Além disso, a avaliação do comprimento da cavidade uterina com o ultrassom, método mais moderno e preciso que o histerômetro, pode orientar para a necessidade de modelos de DIU diferenciados para nuligestas. O objetivo deste trabalho foi avaliar o comprimento da cavidade uterina em mulheres nuligestas e com gestação prévia através da histerometria e do ultrassom. Sujeitos e métodos: Foram avaliadas 570 mulheres (17 a 52 anos) distribuídas em 260 nuligestas e 310 com gestação prévia. Resultados: A diferença entre os valores médios obtidos pela histerometria e pelo ultrassom foi de 0,28cm. O comprimento da cavidade uterina em nuligestas e mulheres com gestação prévia foi 3,84 ± 0,03 e 4,25 ± 0,03, respectivamente, (p < 0,001) pela histerometria e 3,70 ± 0,03 e 3,84 ± 0,03 (média ± EPM), respectivamente pelo ultrassom (p = 0,006). Conclusões: O comprimento da cavidade uterina, avaliado por ambas as técnicas, foi maior entre as mulheres com gestação prévia que entre nuligestas. Esta foi em média maior que 3,6cm, que é o comprimento da maioria dos DIU disponíveis atualmente (TCu 380A) e o sistema liberador de levonorgestrel (LNG-IUS; 3,2cm). Entretanto, um terço das mulheres apresentou valores abaixo dessa medida. Isto permite especular que há poucas razões para o desenvolvimento de novos DIU com comprimento menor, embora exista a possibilidade de um terço das mulheres não se ajustar ao tamanho atual. / Abstract: Introduction and objectives: Due to the controversies about the necessity of new shorter intrauterine devices (IUDs) for nulliparous women in order to reduce expulsion rate, the length of the endometrial cavity was measured in women with different parities by uterine sound and ultrasound. Materials and methods: We evaluated 570 women (17 to 52 years old) distributed on 260 nulliparous and 310 parous. Results: The difference between mean values obtained by the uterine sound and by ultrasound was 0.28 cm. The length of the endometrial cavity on nulliparous and parous women was 3.84 ± 0.03 and 4.25 ± 0.03, respectively (p < 0.001) when assessed by the uterine sound and 3.70 ± 0.03 and 3.84 ± 0.03 (mean ± SEM), respectively when assessed by ultrasound (p = 0.006). Conclusions: The endometrial cavity length evaluated by the two techniques showed a mean value greater than 3.6 cm which is the length of the most worldwide available IUD (TCu380A) and the levonorgestrel-releasing intrauterine system (LNG-IUS). This allows us to speculate that there is no rationale to develop new IUDs with shorter length, because the actual models are fitted to most of the women, including nulliparous. / Mestrado / Ciencias Biomedicas / Mestre em Tocoginecologia
147

Calculo do erro de transmissão de pares engrenados com modificações na microgeometria dos dentes

Wink, Carlos Henrique 30 September 2002 (has links)
Orientador : Alberto Luiz Serpa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-02T10:53:48Z (GMT). No. of bitstreams: 1 Wink_CarlosHenrique_M.pdf: 8271471 bytes, checksum: a23b7712c99373960bf55e7fcdc85f09 (MD5) Previous issue date: 2002 / Resumo: Neste trabalho desenvolveu-se um método de cálculo do erro de transmissão estático de engrenagens helicoidais submetidas à carga. Para isto empregou-se a análise do contato e a determinação da distribuição de carga entre os dentes. Na análise do contato considerou-se o contato também fora do plano de ação, modificações de projeto, erros de fabricação e deflexões dos dentes sob carga que foram calculadas através do método dos coeficientes de influência. Além disto, desenvolveu-se um método interativo com aplicação gradual de carga para determinação da distribuição de carga entre os vários dentes em contato. O procedimento proposto foi implementado em forma de programa computacional e exemplos numéricos foram calculados. Os resultados obtidos foram analisados e comparados com os obtidos em outro programa de reconhecida confiança e as diferenças encontradas foram investigadas e justificadas. Os resultados deste trabalho são importantes para o estudo e compreensão do contato entre os dentes e também para trabalhos futuros de previsão do ruído de engrenagens em um modelo dinâmico / Abstract: A procedure for the analysis of static transmission error of helical gears under load is presented in this work. It gets rid of the assumption that the tooth contact will occur on the plane of action. A complete tooth contact analysis is considered taking into account lead and profile modifications, manufacturing errors and tooth deflections under load. Coefficients of influence method were employed to calculate the tooth deflections and a method to determine the load distribution on gear meshing was developed. The procedure was fully implemented through a computer code and some numerical examples were verified. The results were analyzed and compared to results of other reliable computer program and the differences between results were discussed and their causes were presented. This work presents a relevant contribution to the study and understanding of tooth contact under load, and contributes in the direction of a future work such as the dynamic model for gear noise prediction / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica
148

Filmes finos de MoOx e NixMoOy : aplicação em microbaterias

Rojas Quispe, Jose Ciro 22 July 2003 (has links)
Orientador: Annette Gorenstein / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-03T16:45:59Z (GMT). No. of bitstreams: 1 RojasQuispe_JoseCiro_M.pdf: 1723745 bytes, checksum: 5c6967d1867689b5b522156f60eea3e4 (MD5) Previous issue date: 2003 / Resumo: O rápido crescimento do mercado de dispositivos eletrônicos portáteis com aplicações em diferentes áreas (telecomunicações, medicina, engenharia, etc.) bem como fatores ambientais, criaram uma grande demanda por fontes de potência compactas, leves e sobretudo, de baixo custo. Essa demanda levou ao desenvolvimento de tecnologia de filmes finos para a obtenção dos componentes principais das baterias, gerando o conceito de microbaterias. O presente trabalho procura estudar uma das componentes de microbaterias: os catodos. Filmes finos de óxido de molibdênio e óxidos mistos de molibdênio/níquel foram preparados pela técnica de magnetron sputtering reativo, em diferentes condições de deposição, visando seu uso como catodos em microbaterias recarregáveis de lítio. Estudou-se a influência das variações das condições de deposição sobre a estrutura, composição e performance dos materiais obtidos. No caso dos filmes de óxido de molibdênio, os compostos amorfos e sub-estequiométricos apresentaram uma alta capacidade especifica (178 µAh/cm2 - µm para uma densidade de corrente de 1 µA/cm2). Os resultados referentes à filmes de óxidos mistos de molibdênio/níquel mostraram que a amostra com menor conteúdo de níquel apresentou maior capacidade especifica (152,5 µAh/cm2- µm para uma densidade de corrente 1 µA/cm2) demonstrando a viabilidade da utilização destes materiais em microbaterias / Abstract: The rapid growth of portable electronic devices with applications in distinct areas (telecommunications, medicine, engineering) as well as ambiental factors created a huge demand on compact, light, low cost power sources This demand stimulated the development of thin film technologies for the production of the main parts of batteries, generating the concept of microbatteries. In this work one of this components is studied: the cathode. Hence, thin films of molybdenum oxide and molybdenum/nickel oxides were prepared by reactive magnetron sputtering in distinct deposition conditions, aiming their use in rechargeable lithium microbatteries. The influence of the variation of the deposition conditions on the structure, composition and performance of the materials was studied. In the case of the molybdenum oxide films, the amorphous, sub-stoichiometric compounds presented a high specific capacity (178 µAh/cm2 - µm for a current density of 1 µA/cm2 ). The results concerning the molybdenum/nickel oxides showed that the sample with lower Ni content presented the highest specific capacity (152,5 µAh/cm2 - µm for a current density of 1 µA/cm2) showing up the viability of the utilization of these materials in microbatteries / Mestrado / Física / Mestre em Física
149

Implementação de modelos de amplificadores a fibra dopada em érbio para simulação de enlaces opticos

Bottoli, Mauricio Luis 23 April 1990 (has links)
Orientador: Leonardo de Souza Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-25T10:02:33Z (GMT). No. of bitstreams: 1 Bottoli_MauricioLuis_M.pdf: 11976330 bytes, checksum: 384b1fd48b5ae3fe38592eff72971d7d (MD5) Previous issue date: 1999 / Resumo: Neste trabalho foram desenvolvidos dois modelos para o amplificador óptico: o primeiro é baseado na sua curva de ganho e na resolução do modelo através do valor de ganho máximo; o segundo é baseado na resolução iterativa das equações de taxa que descrevem o dispositivo, utilizando-se os valores das seções transversais de emissão e absorção e o método de Runge- Kutta de quarta ordem para solucionar as equações de taxa. Além disso, foi implementada uma biblioteca de modelos de dispositivos ópticos para o simulador de sistemas SimNT, incluindo os modelos de amplificadores ópticos a fibra dopada com érbio, geradores de pulsos, filtros, acopladores, multiplexadores, demultiplexadores, fonte ópticas, moduladores, geradores de seqüência de bits, dispositivos para visualização e análise de resultados entre outros. Todos os modelos e algoritmos foram desenvolvidos na linguagem C++ / Abstract: In this work two models were developed for the optical amplifier: the first is based on its gain curve and in the resolution of the model through the maximum value of gain; the second is based on the interactive resolution of the rate equations that describe the device, being used the values of the emission and absorption cross sections and the method of Runge-Kutta of fourth order to solve the rate equations. A library of models of optical devices was implemented for the system simulator tool SimNT, including the models of Erbium doped fiber amplifiers, pulse generators, filters, couplers, multiplexers, demultiplexers, optical sources, modulators, bit sequence generators, devices for visualization and analysis of results among others. AlI the models and algorithms were developed in C++ language / Mestrado / Mestre em Engenharia Elétrica
150

Uma contribuição ao estudo de transitorios em dispositivos eletromagneticos utilizando o metodo dos elementos finitos

Alcantara Junior, Naasson Pereira de 12 March 1992 (has links)
Orientador : Ernesto Ruppert Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-14T02:31:03Z (GMT). No. of bitstreams: 1 AlcantaraJunior_NaassonPereirade_D.pdf: 8043508 bytes, checksum: 99e9b0497b7b5f458d670553b13cca5d (MD5) Previous issue date: 1992 / Resumo: Esta tese apresenta dois modelos matemáticos para o estudo de fenômenos transitórios em dispositivos eletromagnéticos. Os model0s são implementados computacionalmente em uma estação de trabalho SUN SPARC 1+. Simulações são realizadas para um pequeno transformador monofásico, com o intuito de estabelecer uma comparação entre os modelos. Resultados de simulações são comparados com resultados de ensaios de laboratório, realizadas com o transformador. Mapas de linhas de fluxo são apresentados para diversos instantes das simulações / Abstract: This thesis presents two models for electromagnetic devices transient analysis. The models are computationall implemented in a SUN SPARC 1+ workstation. Simulations are done for as mall monophase transformer, to stablish a comparison between them. Simulations results are compared with experimetals results, obtained in laboratory to the transformer. Line flux mapping are done for several instants in the simulations / Doutorado / Doutor em Engenharia Elétrica

Page generated in 0.0781 seconds