• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 88
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 90
  • 90
  • 23
  • 20
  • 19
  • 18
  • 16
  • 15
  • 12
  • 11
  • 10
  • 9
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Projeto de um sistema ultra-sonico Doppler pulsatil multicanal para avaliação da vascularização periferica

Plasencia, Jorge Luis Manrique 03 August 2018 (has links)
Orientador: Saide Jorge Calil / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-08-03T21:02:00Z (GMT). No. of bitstreams: 1 Plasencia_JorgeLuisManrique_M.pdf: 3217493 bytes, checksum: c24bd7b3a037a052bddbb858e3d1b5a2 (MD5) Previous issue date: 1994 / Resumo: A procura de um sistema de avaliação do comportamento do fluxo e da velocidade do sangue, de uma forma não invasiva e com uma alta resolução espacial, tem sido um almejado alvo de pesquisadores clínicos. Dentre as varias aplicações para este sistema a de principal interesse é o conhecimento do comportamento hemodinâmico, relevante para o diagnóstico precoce de patologias na vascularização periférica. Os equipamentos de fabricação nacional para esta finalidade, trabalham com sistemas Doppler de onda contínua, que tem a limitação de detectar a existência de turbulências produzidas por obstruções que comprometem no mínimo 50% da luz do vaso. O sistema Ultra-sônico Doppler Multicanal (SUDOF-M) desenvolvido neste trabalho, é capaz de fornecer, ao clínico, informações da distribuição da velocidade do fluxo sanguíneo em função do tempo, em três amostras de volume adjacentes em tempo real, de uma forma não invasiva e não traumática, com a finalidade de detectar turbulências produzidas por estenose de pequeno grau (menores que 30%). Possui também um modo de procura automática, que comandado pelo microcomputador PC/XT, localiza a artéria e mantém os canais de processamento do sinal no centro da luz arterial, dando mais liberdade de atuação para o clínico / Abstract: Not informed / Mestrado / Mestre em Engenharia Elétrica
52

Avaliação ultrassonográfica da artéria carótida comum em equinos da raça Quarto de Milha /

Aguiar, Adriana Cristina Saldanha de. January 2015 (has links)
Orientador: Vânia de Vasconcelos Machado / Coorientador: Noeme Sousa Rocha / Banca: Priscila Macedo de Souza / Banca: Rogério Martins Amorim / Resumo: A artéria carótida comum em equinos se trifurca com algumas variações anatômicas e é o principal vaso que fornece sangue arterial para o cérebro, sendo que é conhecido que sua oclusão causa lesões encefálicas em ratos e humanos. Há muito pouca literatura a respeito de estudos anatômicos e ultrassonográficos desse vaso nessa espécie. Esse estudo avaliou a artéria carótida comum de 50 equinos da raça Quarto de Milha em diferentes idades, divididos em três grupos (grupo I: >2anos, n=14; grupo II: 3-10 anos, n=21; grupo III 15-30 anos, n=15), e obteve valores de referencia para espessura intima-media (EIM), índice de resistividade (IR), índice de pulsatilidade (IP) e diâmetro para ambas artérias carótidas comuns. Os exames foram feitos utilizando um transdutor de 18 MHz no sulco jugular, na altura de C5-C6. O diâmetro esquerdo médio foi de 8,71 ± 1,09 mm para o grupo I; 10,11 ± 0,72 mm para o grupo II e 10,72 ± 0,96 mm para o grupo III. O diâmetro direito médio foi de 8,92 ± 1,24 mm para o grupo I; 10,96 ± 1,06 mm para o grupo II e 11,76 ± 1,07 mm para o grupo III. A EIM foi de 0,90 ± 0,15 mm; 1,02 ± 0,09 mm e 0,97 ± 0,10 mm para os grupos I, II e III, respectivamente. Os valores médios de IR e IP obtidos foram 0,75 ± 0,07 e 1,63 ± 0,33 para o grupo I; 0,81 ± 0,06 e 2,08 ± 0,46 para o grupo II; 0,90 ± 0,10 e 3,20 ± 0,74 para o III, respectivamente. As variáveis IR, IP e EIM não são influenciadas por sexo ou lado, mas sim por idade. Já o diâmetro está correlacionado com o lado e idade, sendo sempre maior do lado direito / Abstract: Common carotid artery in horses trifurcates with some anatomical variations and it is the main supply of arterial blood to the brain. It is known that carotid occlusion can cause encephalic lesions in rats and humans. There are few studies on this vessel, including ultrasonografic evaluation of his vessel in this species. This study evaluated the common carotid artery in 50 American Quarter horses with different ages, separated into three groups (group I: >2years, n=14; group II: 3-10 years, n=21; group III 15-30 years, n=15), and reference values for intima-media thickness (IMT), resistivity index (RI), pulsatility index (PI) and diameter were obtained for both arteries. Exam was performed using an 18 MHz transducer on jugular groove, on level of C5-C6. Mean left diameter was 8.71 ± 1.09 mm for group I; 10.11 ± 0.72 mm for group II and 10.72 ± 0.96 mm for group III. Right diameter was 8.92 ± 1.24 mm for group I; 10.96 ± 1.06 mm for group II and 11.76 ± 1.07 mm for group III. IMT was 0.90 ± 0.15 mm; 1.02 ± 0.09 mm and 0.97 ± 0.10 mm for groups I, II and III, respectively. Mean RI and PI obtained were 0.75 ± 0.07 and 1.63 ± 0.33 for group I; 0.81 ± 0.06 and 2.08 ± 0.46 for group II; 0.90 ± 0.10 and 3.20 ± 0.74 for group III, respectively. The variables RI, PI and IMT are not influenced by gender or side, but were by age. Diameter was influenced by both, age and side, and right diameter was always greater than the left / Mestre
53

Ultrassonografia convencional e Doppler da glândula mamária de caprinos para diagnóstico de mastite /

Santos, Victor José Correia. January 2014 (has links)
Orientador: Wilter Ricardo Russiano Vicente / Coorientador: Marcus Antonio Rossi Feliciano / Coorientador: Luiz Fernando de Souza Rodrigues / Coorientador: Maria Emilia Franco Oliveira / Banca: Joaquim Mansano Garcia / Banca: Érika da Silva Carvalho Morani / Resumo: Sugere-se que as ultrassonografias convencional e Doppler podem ser utilizadas para se obter o diagnóstico da mastite em caprinos, de forma confiável e não invasiva. Neste trabalho objetivou-se avaliar as características ultrassonográficas das glândulas mamárias e determinar os índices vasculares da artéria mamária de caprinos saudáveis, com mastite subclínica e clínica. Foram utilizadas 30 cabras das raças Saanen e Alpina Francesa em idade reprodutiva (de 2 a 5 anos) divididas em três grupos, animais saudáveis (GS), com mastite subclínica (GMSC) e com mastite clínica (GMC). Os animais foram submetidos ao exame clínico a fim de verificar sinais que indicassem a ocorrência de mastite. O leite foi avaliado pelos métodos da caneca de fundo preto e "California Mastitis Test" (CMT). Por meio da ultrassonografia convencional (Modo-B) do úbere observaram-se as características sonográficas (ecotextura e ecogenicidade) e biométricas das estruturas do órgão (diâmetro e área da cisterna do úbere, diâmetro e área da cisterna da papila mamária, e espessura da parede da papila mamária). Com a ultrassonografia Doppler, foram obtidos os índices vasculares da artéria mamária. Os resultados revelaram hiperecogenicidade com componente sólido para a cisterna da glândula, quando comparado o tecido de animais com mastite clínica com tecido mamário saudável. Em relação à ecotextura do tecido mamário, nos três grupos, verificou-se heterogeneidade do parênquima mamário e para o leite, homogeneidade para animais do GS e GMSC e heterogeneidade para animais do GMC. A avaliação quantitativa da ecogenicidade demonstrou um aumento de ecogenicidade (valor médio) para todas as estruturas ao se comparar os grupos experimentais. A biometria não revelou diferença estatística entre os grupos para nenhuma estrutura avaliada. Ao exame Modo-Doppler da artéria mamária verificou-se redução dos valores obtidos para a ... / Abstract: It's suggested that both B-mode and Doppler ultrasonography could be used to obtain the diagnosis of mastitis in goats on a trustful and non-invasive way, therefore, this study aims to evaluate the sonographic characteristics of the udder and teats and to determine the Doppler indexes of mammary artery at its bifurcation in healthy animals, as well as in animals with both subclinical or clinical mastitis. Thirty animals among Saanen and Alpine Brown goats aged between 2 and 5 years were arranged in three groups, healthy animals (GS), animals with subclinical mastitis (GMSC) and animals with clinical mastitis (GMC). The animals underwent clinical examinations to verify the occurrence of mastitis. The milk was evaluated using the strip cup test and California Mastitis Test (CMT). Using the B-mode, the sonographic characteristics (echotexture and echogenicity) and biometry (diameter and area of the udder cistern, diameter and area of the teat cistern and thickness of the teat wall) were evaluated. Using Doppler ultrasonography, the vascular indexes of the mammary artery were obtained. It was observed hiperecogenicity with solid component in the gland cistern when comparing animals with clinical mastitis and healthy mammary tissue. Regarding the echotexture of the breast tissue, there was heterogeneity in the mammary parenchyma on the three groups, for the milk, it was observed homogeneity for animals on GS and GMSC and heterogeneity for animals on GMC. Grey-scale quantitative assessment revealed increase in echogenicity (mean value) for all the structures when comparing the three groups. Biometry didn't reveal statistical difference between groups, for none of the evaluated structures. Doppler examination of the mammary artery showed the decrease of final diastolic velocity (VDF) and raise of pulsatility index (IP) between groups. The association of B-mode and Doppler ultrasonography is useful for the evaluation of the udder of ... / Mestre
54

Avaliação ultrassonográfica hepática ao modo-B, dúplex e tríplex Doppler de cães com sobrepeso e obesos /

Belotta, Alexandra Frey. January 2015 (has links)
Orientador: Maria Jaqueline Mamprim / Coorientador: Carlos Roberto Teixeira / Banca: Raquel Sartor Marcelino / Banca: Alessandra Melchert / Resumo: O atendimento de cães com sobrepeso e obesos na rotina clínica de animais de companhia tem sido cada vez mais frequente. O objetivo do presente estudo foi avaliar as alterações hepáticas parenquimatosas e hemodinâmicas, por meio da ultrassonografia bidimensional e Doppler, em três grupos de cães com diferentes escores de condição corporal - G1 (peso ideal/controle), G2 (sobrepeso) e G3 (obesos) -, sem doenças hepáticas por outras causas de base. Houve correlação positiva entre o G3 e os seguintes fatores: aumento da ecogenicidade do parênquima hepático, aumento das dimensões hepáticas, hiperlipidemia, e morfologia anormal da onda da veia hepática (VH). Diferença significativa na velocidade média do fluxo portal (Vméd.VP) foi observada entre G1 (17,23 ± 3,7cm/s) e G3 (13,66 ± 2,56cm/s), no volume do fluxo portal (VFVP) entre G1 (32,69 ± 11,86mL/min/kg) e G2 (19,58 ± 7,68mL/min/kg) e entre G1 e G3 (15,22 ± 8mL/min/kg), no índice hepatorrenal entre G2 (1,1 ± 0,29) e G3 (1,28 ± 0,22), nos níveis séricos de fosfatase alcalina (FA) entre G1 e G3, de gama glutamiltransferase (GGT) entre G1 e G2 e de colesterol entre G1 e os demais grupos. Não houve diferença significativa no índice de congestão portal (ICP), no índice de resistividade da artéria hepática (IRAH), no diâmetro e área da veia porta e nos níveis séricos de alanina aminotransferase (ALT) e triglicérides, entre os grupos. Concluiu-se que a obesidade pode levar ao desenvolvimento de alterações parenquimatosas e hemodinâmicas no fígado de cães / Abstract: Veterinary care of overweight and obese dogs in small animal clinical sciences has become increasingly common. The aim of the present study was to investigate, using two dimensional and Doppler sonography, parenchymal and hemodynamic changes in three groups of dogs, according to body score condition (G1, ideal body weight/control; G2, overweight; G3, obese), without hepatic diseases due to other causes. A positive correlation was found between G3 and the characteristics described below: increased liver echogenicity, hepatomegaly, hiperlipidemia and abnormal hepatic vein Doppler waveform pattern. There was statistical difference in the mean portal blood flow velocity between G1 (17,23 ± 3,7cm/s) and G3 (13,66 ± 2,56cm/s), in the portal blood flow between G1 (32,69 ± 11,86mL/min/kg) and G2 (19,58 ± 7,68mL/min/kg) and between G1 and G3 (15,22 ± 8mL/min/kg), in the hepatorenal index between G2 (1,1 ± 0,29) and G3 (1,28 ± 0,22), in serum levels of alkaline phosphatase (ALP) between G1 and G3, in levels of gamma glutamyltranspeptidase (GGT) between G1 and G2 and in levels of cholesterol between G1 and the other groups. There was no statistical difference in the portal vein congestion index, hepatic artery resistance index, portal vein diameter and area and on serum levels of alanine aminotransferase (ALT) and triglycerides between the groups. It was concluded that obesity may be responsible for the development of parenchymal and hemodynamic changes in dog's liver / Mestre
55

Avaliação ultrassonográfica quantitativa e qualitativa do canal do carpo em equinos

Evangelista, Felipe Carvalho [UNESP] 28 June 2013 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:50:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-06-28Bitstream added on 2014-08-13T18:00:42Z : No. of bitstreams: 1 000755547_20150628.pdf: 250824 bytes, checksum: 795dea93e01fd5ccf15d5ca4b855d266 (MD5) Bitstreams deleted on 2015-06-30T11:22:15Z: 000755547_20150628.pdf,. Added 1 bitstream(s) on 2015-06-30T11:23:08Z : No. of bitstreams: 1 000755547.pdf: 2462293 bytes, checksum: 04864172a4ab96dc6e73edd28ba4e665 (MD5) / O canal do carpo foi avaliado ultrassonograficamente em 60 equinos da raça quarto de milha de corrida, hígidos, em diferentes faixas etárias. Os animais foram divididos em três grupos: potros, adultos jovens e adultos, contendo 10 machos e 10 fêmeas em cada grupo. O objetivo deste estudo foi a caracterização e padronização das estruturas do canal do carpo, pelo exame ultrassonográfico modo B e pelo exame ultrassonográfico Doppler. Dentro do canal do carpo foram avaliados os tendões flexores digitais superficial e profundo, juntamente com o tendão flexor carpo radial. Para cada tendão foi mensurado as dimensões de altura dorso palmar, largura médio lateral e a área dos tendões. Além dos tendões, foram avaliados os nervos palmar medial e palmar lateral, conforme a morfologia normal e a dimensão dorso palmar. No exame ultrassonográfico modo Doppler foram padronizados os índices dopplerfluxométricos das artérias radial e ramo palmar da artéria mediana. Para padronização de ecogenicidade e ecotextura dos tendões foram realizados o histograma. As médias da área do TFDS variaram de 99,20 a 123,20 mm2, do TFDP 114,60 a 143,80 mm2 e o TFCR 17,50 a 24,22 mm2. As médias do diâmetro do retináculo flexor variaram de 1,33 a 1,55 mm, do nervo palmar lateral de 0,93 a 1,09 mm, o do nervo palmar medial 1,10 a 1,44 mm, da artéria radial de 2,54 a 3,06 mm e da artéria palmar medial de 4,23 a 5,47. As médias do índice de resistividade e pulsatilidade da artéria radial variaram de 0,82 a 0,88 e 2,02 a 3,73, respectivamente. As médias do índice de resistividade e pulsatilidade da artéria palmar medial variaram 0,72 a 0,84 e 1,71 a 2,73. Neste estudo foi possível concluir que não ocorreu diferença entre os membros direito e esquerdo para o mesmo animal. Há tendência dos animais adultos apresentaram os tendões maiores e mais heterogêneos do que os adultos jovens e potros. Embora existam diferenças estatísticas entre as ... / The carpal tunnel was sonographically evaluated in 60 quarter horse healthy equines in different age groups, divided into three groups, being these foals, young adults and adults, with 10 males and 10 females in each group. The aim of this study was the characterization and standardization of the structures of the carpal tunnel, through the ultrasound B-mode and the Doppler ultrasonography. Within the carpal tunnel were evaluated superficial digital flexor tendon and deep with the radial carpal flexor tendon. For each tendon was measured the height dimensions dorsal palmar, the medial lateral width and the area of the tendons. Besides the tendons were evaluated the medial palmar nerves and the lateral palmar according to the normal morphology and dorsal palmar dimension. In the Doppler ultrasound were standardized the Dopplerfluxometry indices of the radial arteries and palmar branch of the median artery. For the echogenicity and echotexture standardization of the tendons were performed the histogram. The mean area of the TSDF ranged from 99.20 to 123.20 mm2, of the TDDF from 114.60 to 143.80 mm2 and of the TFCR from 17.50 to 24.22 mm2. The mean diameter of the flexor retinaculum ranged from 1.33 to 1.55 mm, of the lateral palmar nerve from 0.93 to 1.09 mm, of the medial nerve palmar from 1.10 to 1.44 mm, of the artery radial from 2.54 to 3.06 mm and of the medial palmar artery from 4.23 to 5.47. The mean of the resistivity and pulsatility indexes of the radial artery ranged from 0.82 to 0.88 and from 2.02 to 3.73, respectively. The mean resistivity and pulsatility indexes of the medial palmar artery ranged from 0.72 to 0.84 and from 1.71 to 2.73, respectively. The mean resistivity and pulsatility indexes of the medial palmar artery ranged from 0.72 to 0.84 and from 1.71 to 2.73. In this study was concluded that there was no difference between the right and left limbs for the same animal and there is ...
56

Ultrassonografia convencional e Doppler da glândula mamária de caprinos para diagnóstico de mastite

Santos, Victor José Correia [UNESP] 24 February 2014 (has links) (PDF)
Made available in DSpace on 2015-04-09T12:28:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-24Bitstream added on 2015-04-09T12:48:10Z : No. of bitstreams: 1 000815840.pdf: 391408 bytes, checksum: c48b1a98d57e737982ccb63ca3a3b175 (MD5) / Sugere-se que as ultrassonografias convencional e Doppler podem ser utilizadas para se obter o diagnóstico da mastite em caprinos, de forma confiável e não invasiva. Neste trabalho objetivou-se avaliar as características ultrassonográficas das glândulas mamárias e determinar os índices vasculares da artéria mamária de caprinos saudáveis, com mastite subclínica e clínica. Foram utilizadas 30 cabras das raças Saanen e Alpina Francesa em idade reprodutiva (de 2 a 5 anos) divididas em três grupos, animais saudáveis (GS), com mastite subclínica (GMSC) e com mastite clínica (GMC). Os animais foram submetidos ao exame clínico a fim de verificar sinais que indicassem a ocorrência de mastite. O leite foi avaliado pelos métodos da caneca de fundo preto e “California Mastitis Test” (CMT). Por meio da ultrassonografia convencional (Modo-B) do úbere observaram-se as características sonográficas (ecotextura e ecogenicidade) e biométricas das estruturas do órgão (diâmetro e área da cisterna do úbere, diâmetro e área da cisterna da papila mamária, e espessura da parede da papila mamária). Com a ultrassonografia Doppler, foram obtidos os índices vasculares da artéria mamária. Os resultados revelaram hiperecogenicidade com componente sólido para a cisterna da glândula, quando comparado o tecido de animais com mastite clínica com tecido mamário saudável. Em relação à ecotextura do tecido mamário, nos três grupos, verificou-se heterogeneidade do parênquima mamário e para o leite, homogeneidade para animais do GS e GMSC e heterogeneidade para animais do GMC. A avaliação quantitativa da ecogenicidade demonstrou um aumento de ecogenicidade (valor médio) para todas as estruturas ao se comparar os grupos experimentais. A biometria não revelou diferença estatística entre os grupos para nenhuma estrutura avaliada. Ao exame Modo-Doppler da artéria mamária verificou-se redução dos valores obtidos para a ... / It’s suggested that both B-mode and Doppler ultrasonography could be used to obtain the diagnosis of mastitis in goats on a trustful and non-invasive way, therefore, this study aims to evaluate the sonographic characteristics of the udder and teats and to determine the Doppler indexes of mammary artery at its bifurcation in healthy animals, as well as in animals with both subclinical or clinical mastitis. Thirty animals among Saanen and Alpine Brown goats aged between 2 and 5 years were arranged in three groups, healthy animals (GS), animals with subclinical mastitis (GMSC) and animals with clinical mastitis (GMC). The animals underwent clinical examinations to verify the occurrence of mastitis. The milk was evaluated using the strip cup test and California Mastitis Test (CMT). Using the B-mode, the sonographic characteristics (echotexture and echogenicity) and biometry (diameter and area of the udder cistern, diameter and area of the teat cistern and thickness of the teat wall) were evaluated. Using Doppler ultrasonography, the vascular indexes of the mammary artery were obtained. It was observed hiperecogenicity with solid component in the gland cistern when comparing animals with clinical mastitis and healthy mammary tissue. Regarding the echotexture of the breast tissue, there was heterogeneity in the mammary parenchyma on the three groups, for the milk, it was observed homogeneity for animals on GS and GMSC and heterogeneity for animals on GMC. Grey-scale quantitative assessment revealed increase in echogenicity (mean value) for all the structures when comparing the three groups. Biometry didn’t reveal statistical difference between groups, for none of the evaluated structures. Doppler examination of the mammary artery showed the decrease of final diastolic velocity (VDF) and raise of pulsatility index (IP) between groups. The association of B-mode and Doppler ultrasonography is useful for the evaluation of the udder of ...
57

Avaliação hepática de cães naturalmente infectados por leishmaniose visceral canina : aspectos ultrassonográficos modo B e Doppler /

Oliveira, Hugo Salvador. January 2015 (has links)
Orientador: Maria Jaqueline Mamprim / Banca: Sheila Canavese Rahal / Banca: Raquel Sartor Marcelino / Resumo: O presente estudo teve como objetivo descrever as imagens ultrassonográficas realizadas pelo modo B, dopplerfluxometria dos vasos hepáticos, juntamente com o perfil bioquímico e a analise histopatológica do fígado de cães naturalmente acometidos pela Leishmaniose visceral canina. Foram avaliados 46 cães, naturalmente infectados, com diagnóstico sorológico ou parasitológico positivo para Leishmania spp., oriundos do município de Bauru, São Paulo. Como resultado do exame histopatológico apresentou característica processo inflamatório crônico presente em todos os animais. No ultrassom ecogenicidade do fígado diminuída em 56,5% dos casos e característica espectral das veias hepáticas alterada em 73,9% dos animais. Nos valores quantitativos a velocidade media da veia porta foi de 22,06cm/s, do pico sistólico da artéria hepática foi de 76,8cm/s e o índice de resistividade da artéria hepática 0,65 demonstrando uma correlação positiva entre as duas variáveis. O perfil bioquímico do fígado se mostrou inconclusivo, pois não demonstrou valores relevantes, mesmo os animais com alterações significativas nos exames de ultrassom e histopatológico. Não foram caracterizadas lesões especificas para a leishmaniose visceral canina, porém pode-se confirmar o curso crônico da doença, e que o ultrassom, principalmente o modo Doppler, tem se mostrado precoce na detecção de alterações hepáticas em cães / Abstract: O presente estudo teve como objetivo descrever as imagens ultrassonográficas realizadas pelo modo B, dopplerfluxometria dos vasos hepáticos, juntamente com o perfil bioquímico e a analise histopatológica do fígado de cães naturalmente acometidos pela Leishmaniose visceral canina. Foram avaliados 46 cães, naturalmente infectados, com diagnóstico sorológico ou parasitológico positivo para Leishmania spp., oriundos do município de Bauru, São Paulo. Como resultado do exame histopatológico apresentou característica processo inflamatório crônico presente em todos os animais. No ultrassom ecogenicidade do fígado diminuída em 56,5% dos casos e característica espectral das veias hepáticas alterada em 73,9% dos animais. Nos valores quantitativos a velocidade media da veia porta foi de 22,06cm/s, do pico sistólico da artéria hepática foi de 76,8cm/s e o índice de resistividade da artéria hepática 0,65 demonstrando uma correlação positiva entre as duas variáveis. O perfil bioquímico do fígado se mostrou inconclusivo, pois não demonstrou valores relevantes, mesmo os animais com alterações significativas nos exames de ultrassom e histopatológico. Não foram caracterizadas lesões especificas para a leishmaniose visceral canina, porém pode-se confirmar o curso crônico da doença, e que o ultrassom, principalmente o modo Doppler, tem se mostrado precoce na detecção de alterações hepáticas em cães / Mestre
58

Resposta hemodinâmica materno-fetal com a nitroglicerina transdérmica, em gestantes com pré-eclampsia grave, insuficiência placentária e prematuridade importante

Trapani Júnior, Alberto 25 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Ciências Médicas, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T09:21:48Z (GMT). No. of bitstreams: 0 / Avaliar o efeito da nitroglicerina transdérmica em pacientes com pré-eclampsia grave, associada a insuficiência placentária e prematuridade importante, através da dopplervelocimetria das artérias uterinas, umbilical e cerebral média. Em 30 gestantes, entre 24 e 31 semanas, com pré-eclampsia grave e alteração basal ao Doppler uterino e feto-placentário, avaliou-se o Índice de pulsatividade (IP) e o índice de resistência (IR) das artérias uterinas, umbilical e cerebral média, antes e durante três dias de uso da nitroglicerina transdérmica, com adesivos de liberação média de 0,4 mg por hora. Avaliou-se também a variação da pressão arterial média, com e sem o adesivo. RESULTADOS: A nitroglicerina transdérmica determinou uma diminuição significativa no IP e IR das artérias uterinas (25,3% +/- 4,9% e 21,2% +/- 6,2%, respectivamente) e da artéria umbilical (23,1 +/- 6,9% e 19,7 +/- 6,1%, respectivamente), comparando o primeiro dia, sem a medicação e o terceiro dia de adesivo. Não verificou-se alterações nos índices estudados na artéria cerebral média. A pressão arterial média diminuiu de 119,5 +/- 4,5 para 114,8 +/- 4,4 mmHg (P<0,05). CONCLUSÃO: A administração da nitroglicerina transdérmica, em gestantes com pré-eclampsia grave, está associada à diminuição da resistência ao fluxo sanguíneo nas artérias uterinas e do cordão umbilical, além de uma queda na pressão arterial materna, sem alteração na dopplervelocimetria da artéria cerebral média fetal.
59

Contribuição para a avaliação de acessos vasculares em pacientes de hemodiálise com ultra-som doppler de ondas contínuas

Molina, Paulo Sergio Correa January 2004 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-22T05:06:34Z (GMT). No. of bitstreams: 0 / Na hemodiálise, sangue é retirado, filtrado e devolvido ao paciente. Para isto, confecciona-se acesso vascular que permite canulação para saída e retorno do sangue. A falha do acesso é fonte de morbidade e hospitalização, podendo ser identificada prematuramente através da medição de fluxo sangüíneo no acesso. No entanto, as atuais técnicas de medição são de custo elevado ou pouco práticas, não sendo normalmente utilizadas no Brasil. Neste trabalho, desenvolveu-se um sistema de ultra-som Doppler direcional de ondas contínuas, constituído por uma placa para geração de ultra-som e demodulação de sinais Doppler. Estes sinais são aplicados à placa de som de um notebook onde são amostrados e processados. Sonograma e envoltórias de velocidade são calculados e apresentados na tela do notebook. Com o sistema desenvolvido, sinais de acessos vasculares de 17 pacientes foram amostrados. O método da variação de fluxo (recentemente descrito na literatura) foi aplicado a estes sinais para avaliar seu potencial, tendo sido desenvolvido software para esta finalidade. Este método determina o fluxo do acesso alterando-se o fluxo da máquina de hemodiálise. Limitações para a aplicação do método foram encontradas. Foi proposto método de classificação de fluxo através do índice de espalhamento espectral (SBI). SBI maior que 1,9 corresponde a fluxo inferior a 600 ml/min, indicando problemas no acesso. O método apresentou sensibilidade de 80% e especificidade de 83%, devendo ser validado para maior número de pacientes. A validação do método proposto pode auxiliar na disseminação de programas de monitoração de acessos, como recomendado internacionalmente.
60

Avaliação ultrassonográfica da artéria carótida comum em equinos da raça Quarto de Milha / Ultrasonografic evaluation of the common carotic artery in American Quarter Horses

Aguiar, Adriana Cristina Saldanha de [UNESP] 16 January 2015 (has links) (PDF)
Made available in DSpace on 2015-10-06T13:02:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-01-16. Added 1 bitstream(s) on 2015-10-06T13:19:40Z : No. of bitstreams: 1 000847520_20160120.pdf: 125282 bytes, checksum: c5aa36578924d7b8ee5b6a5975361246 (MD5) Bitstreams deleted on 2016-01-22T12:10:21Z: 000847520_20160120.pdf,. Added 1 bitstream(s) on 2016-01-22T12:10:56Z : No. of bitstreams: 1 000847520.pdf: 1274871 bytes, checksum: 8c9c67689d005bfad1504a2df6ddeaa4 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / A artéria carótida comum em equinos se trifurca com algumas variações anatômicas e é o principal vaso que fornece sangue arterial para o cérebro, sendo que é conhecido que sua oclusão causa lesões encefálicas em ratos e humanos. Há muito pouca literatura a respeito de estudos anatômicos e ultrassonográficos desse vaso nessa espécie. Esse estudo avaliou a artéria carótida comum de 50 equinos da raça Quarto de Milha em diferentes idades, divididos em três grupos (grupo I: >2anos, n=14; grupo II: 3-10 anos, n=21; grupo III 15-30 anos, n=15), e obteve valores de referencia para espessura intima-media (EIM), índice de resistividade (IR), índice de pulsatilidade (IP) e diâmetro para ambas artérias carótidas comuns. Os exames foram feitos utilizando um transdutor de 18 MHz no sulco jugular, na altura de C5-C6. O diâmetro esquerdo médio foi de 8,71 ± 1,09 mm para o grupo I; 10,11 ± 0,72 mm para o grupo II e 10,72 ± 0,96 mm para o grupo III. O diâmetro direito médio foi de 8,92 ± 1,24 mm para o grupo I; 10,96 ± 1,06 mm para o grupo II e 11,76 ± 1,07 mm para o grupo III. A EIM foi de 0,90 ± 0,15 mm; 1,02 ± 0,09 mm e 0,97 ± 0,10 mm para os grupos I, II e III, respectivamente. Os valores médios de IR e IP obtidos foram 0,75 ± 0,07 e 1,63 ± 0,33 para o grupo I; 0,81 ± 0,06 e 2,08 ± 0,46 para o grupo II; 0,90 ± 0,10 e 3,20 ± 0,74 para o III, respectivamente. As variáveis IR, IP e EIM não são influenciadas por sexo ou lado, mas sim por idade. Já o diâmetro está correlacionado com o lado e idade, sendo sempre maior do lado direito / Common carotid artery in horses trifurcates with some anatomical variations and it is the main supply of arterial blood to the brain. It is known that carotid occlusion can cause encephalic lesions in rats and humans. There are few studies on this vessel, including ultrasonografic evaluation of his vessel in this species. This study evaluated the common carotid artery in 50 American Quarter horses with different ages, separated into three groups (group I: >2years, n=14; group II: 3-10 years, n=21; group III 15-30 years, n=15), and reference values for intima-media thickness (IMT), resistivity index (RI), pulsatility index (PI) and diameter were obtained for both arteries. Exam was performed using an 18 MHz transducer on jugular groove, on level of C5-C6. Mean left diameter was 8.71 ± 1.09 mm for group I; 10.11 ± 0.72 mm for group II and 10.72 ± 0.96 mm for group III. Right diameter was 8.92 ± 1.24 mm for group I; 10.96 ± 1.06 mm for group II and 11.76 ± 1.07 mm for group III. IMT was 0.90 ± 0.15 mm; 1.02 ± 0.09 mm and 0.97 ± 0.10 mm for groups I, II and III, respectively. Mean RI and PI obtained were 0.75 ± 0.07 and 1.63 ± 0.33 for group I; 0.81 ± 0.06 and 2.08 ± 0.46 for group II; 0.90 ± 0.10 and 3.20 ± 0.74 for group III, respectively. The variables RI, PI and IMT are not influenced by gender or side, but were by age. Diameter was influenced by both, age and side, and right diameter was always greater than the left

Page generated in 0.0964 seconds