Spelling suggestions: "subject:"dos."" "subject:"done.""
431 |
Lixiviação e eficácia de controle de plantas daninhas da formulação de diurom + hexazinona + sulfometurom-metílico em diferentes solos, condições hídricas e presença de palha / Leaching and efficacy for weed control by the formulation of diuron + hexazinone + sulfometuron-methyl in different soils, hydric conditions and presence of strawGarcia, Danilo de Brito 12 September 2012 (has links)
A expansão das áreas cultivadas com cana-de-açúcar no Brasil é evidente, e para um eficaz manejo dessas extensas áreas, é necessário um bom planejamento das operações agrícolas. Nesse sentido, a aplicação de herbicidas pode ocorrer até no período seco do ano e em condições de solo bem distintas. Sabe-se que os diferentes ambientes nos quais os herbicidas são aplicados têm grande influencia em sua eficácia, e entender essas diferenças é importante para se obter o melhor rendimento e se fazer o correto uso dessa excelente ferramenta de manejo. Assim, este trabalho teve como objetivo avaliar o comportamento da formulação comercial contendo os herbicidas diurom + hexazinona + sulfometurom-metílico quando aplicado em solos com texturas contrastantes, além de avaliar a lixiviação desse herbicida e seus componentes e também como condições de restrição hídrica em presença de palha de cana-de-açúcar podem afetar o seu efeito residual e de seus componentes. Foram realizados ao todo 5 experimentos sendo 3 com o uso de curvas de dose-resposta, avaliando-se capim-colchão e corda-de-viola; um com lixiviação em tubos de PVC, avaliando-se corda-de-viola, e um com períodos de restrição hídrica, avaliando-se corda-de-viola e capim-colonião. Os resultados obtidos nos experimentos com as curvas de dose-resposta demonstraram a grande influencia da textura na eficácia do herbicida, com quantidades de argila menores que 30% sendo suficientes para gerar respostas consideravelmente distintas. O experimento com lixiviação demonstrou que as três moléculas do herbicida comportam-se diferentemente no solo, o que também é importante para o seu uso em diferentes ambientes. Os resultados obtidos no experimento com períodos de restrição hídrica em palha de cana-de-açúcar permitem concluir que apesar de as três moléculas comportarem-se diferentemente no ambiente, elas se complementam no controle de plantas daninhas mono e dicotiledôneas, e têm o efeito residual pouco influenciado por períodos de restrição hídrica. / The expansion of areas planted with sugar cane in Brazil is clearly noticeable and a good planning of agricultural operations is necessary for an effective management of these extensive areas. Accordingly, the application of herbicides may occur even in the dry season and in distinctive soil conditions. It is known that the different environments in which the herbicides are applied have great influence on their effectiveness and understanding these differences is an important factor in order to obtain best performance and make proper use of this excellent management tool. Thus, this work aimed to evaluate the behavior of the commercial formulation containing the herbicides diuron + hexazinone + sulfometurom-methyl when applied to soils with contrasting textures, and also to evaluate the leaching of this herbicide and its components as well as how conditions of water restriction with presence of sugarcane staw can affect your residual effect and its components. Five experiments were performed, three of those using dose-response curves, to evaluate crabgrass and morning glory; one with leaching using PVC tubes, evaluating morning glory and one with periods of water restriction, evaluating morning glory and guinea grass. Obtained results of the experiments with the dose-response curves demonstrated the great influence of the texture on the effectiveness of the herbicide, clay amounts of less than 30% being sufficient to generate considerably distinct responses. The experiment with leaching showed that the three molecules behave differently in the soil, which is also important to their use in different environments. Obtained results in the experiment with periods of water restriction on straw sugarcane allow the conclusion that although the three molecules behave differently in the environment, they complement each other in control of mono and dicotyledonous weeds, and they have little residual effect influenced by periods of water restriction.
|
432 |
Monitoração de Rn-222 nos galpões de armazenamento de rejeitos radioativos do IPEN / 222Rn monitoring in the radioactive storage IPENFábio Henrique Manocchi 04 August 2014 (has links)
Neste trabalho foi avaliada a dose efetiva recebida pelos trabalhadores da Gerência de Rejeitos Radioativos do IPEN devido à inalação de 222Rn nos galpões de armazenamento de rejeitos radioativos tratados e não tratados. As concentrações de 222Rn no interior dos galpões foram determinadas por meio da técnica de detecção passiva com detectores de traços nucleares do estado sólido (SSNTD). O detector utilizado foi o CR-39 inserido em uma câmara de difusão do tipo NRPB. Foram monitorados um total de 12 pontos internos e 1 ponto externo no galpão de rejeitos radioativos tratados G4 e 13 pontos no galpão de rejeitos radioativos não tratados G3, durante um período de 11 meses, entre junho de 2012 e maio de 2013. As concentrações variaram de 0,73 ± 0,08 e 4,55 ± 0,16 kBqm-3 entre os períodos de monitoramento no galpão G4 e entre 0,61 ± 0,07 e 2,94 ± 0,12 kBqm-3 no galpão G3. A dose efetiva devido à inalação de 222Rn no interior dos galpões de rejeitos radioativos foi calculada de acordo com os procedimentos da Comissão Internacional de Proteção Radiológica (ICRP) a partir de um fator de conversão de dose, da concentração média do 222Rn no ar e do tempo de exposição dos indivíduos. Os valores de doses apresentados são uma média das concentrações entre os períodos de monitoramento que variam 15,70 mSva-1 no G4 e de 9,27 mSva-1 no G3, sendo que em um dos períodos obteve-se valores superiores ao estabelecidos pelo órgão regulador (CNEN) e recomendados pela Comissão Internacional de Proteção Radiológica (ICRP) de 20 mSva-1 para indivíduos ocupacionalmente expostos, indicando a necessidade de medidas mitigadoras. Cabe, contudo, informar que foi considerada uma hipótese bastante conservativa de 2000 horas de trabalho no local. / Some radionuclides that make up the radioactive series are noted for their contribution to the total exposure to which individuals are subjected, an important example is known as radon 222Rn and their descendants, responsible for more than half of the radiation dose received by the population due to natural sources. In this work the effective dose received by the workers of the Management of Radioactive Waste in IPEN due to inhalation of 222Rn in storage sheds from treated and untreated radioactive waste was evaluated. Concentrations of 222Rn inside the sheds of treated and untreated radioactive waste G3 and G4 were determined by the technique of passive detection with solid state nuclear track (SSNTD) detectors. The detector used was CR-39 inserted in a diffusion chamber type NRPB. A total of 12 internal points and 1 external point were monitored in the shed radioactive waste treated G4 and 13 points in the shed radioactive waste untreated G3, for a period of 11 months between June 2012 and May 2013. Concentrations ranged 0.73 ± 0.08 to 4.55 ± 0.16 kBqm-3 among the monitoring periods in the shed G4 and between 0.61 ± 0.07 and 2.94 ± 0.12 kBqm-3 in the shed G3. The effective dose due to inhalation of 222Rn inside the sheds radioactive waste was calculated according to the procedures of the International Commission on Radiological Protection (ICRP) from a conversion factor of dose, the mean concentration of 222Rn in the air and time of exposure of individuals. The dose values for G4 and G3 are 15.70 and 9.27 mSva-1 respectively, this being greater than the value established by the National Nuclear Energy Commission (CNEN) and recommended by the International Commission on Radiological Protection (ICRP) 20 mSv / a for occupationally exposed individuals, thus indicating the need for mitigation measures. It should, however, report that was considered a very conservative assumption of 2,000 hours of work on site.
|
433 |
Modelos de dose-resposta com censura intervalar aplicados a dados de germinação de sementes / Dose-response models with interval-censored applied to seed germination dataAzevedo, Iábita Fabiana Sousa 26 August 2016 (has links)
O crescimento de investimentos em biotecnologia na agricultura tem sido um elemento primordial para a segurança alimentar global. Isso tem levado a uma reorganização da indústria mundial de sementes na busca por técnicas mais adequadas de cultivo, mecanização, uso de fertilizantes, defensivos agrícolas e a utilização de sementes. O Brasil por ser um dos ambientes mais sólidos nesse contexto tem contribuído com o crescimento e a diversificação da produção de sementes levando as lavouras brasileiras a atingirem um novo patamar de produtividade. Diferentes metodologias estatísticas têm sido utilizadas para analisar o comportamento da germinação de uma população de sementes. Entretanto, usar abordagens estatísticas que analisam os dados de germinação da melhor maneira possível permitirá uma maior confiabilidade dos resultados, bem como, ganho de informações pertinentes. Como em testes de germinação de sementes estuda-se o tempo até a ocorrência do evento, que envolve medidas repetidas feitas no mesmo lote e não se conhece o tempo exato da germinação da semente, propõe-se o uso de modelos de dose-resposta com censura intervalar, que permitem a interpretação biológica dos parâmetros usados para medir o processo germinativo e refletem o desenho experimental dos dados. Neste trabalho foram utilizadas duas metodologias estatísticas usuais na análise de dados de germinação de sementes e seus resultados foram comparados com os da abordagem de modelos dose-resposta com censura intervalar. Foram utilizados os modelos de dose-resposta Weibull 2 e log-logístico para explicar o processo germinativo de sementes de Brachiaria e Citrumelo Swingle respectivamente, com diferentes tempos de observação. Os experimentos foram realizados em delineamento inteiramente aleatorizado e os procedimentos dos testes de germinação de acordo com as Regras para Análise de Sementes (RAS). As conclusões obtidas a partir da análise dos dados por meio da metodologia proposta, em geral, divergiram das conclusões obtidas por abordagens tradicionais (modelos de regressão não-linear considerando a distribuição normal e índices de germinação com o uso da análise de variância) utilizadas para analisar dados de germinação. Os modelos de dose-resposta com censura intervalar apresentaram ajustes satisfatórios e sendo portanto uma análise mais adequada que as abordagens usuais. / The growth of investment in biotechnology in agriculture has been a vital element for global food security. This has led to a reorganization of the world seed industry in the seeking of the most appropriate techniques of cultivation, mechanization, use of fertilizers, pesticides and seeds. The Brazil for being one of the most solid in the world context of the seed industry has contributed to the growth and diversification of seed production, leading Brazilian crops to a new level of productivity. Different statistical methodologies have been used to analyze the germination behavior. However, using statistical approaches that analyze germination data as efficiently as possible will allow a greater reliability of the results, as well as relevant information gain. As in seed germination test studies the time until the occurrence of the event, involves repeated measurements on the same experimental unit and do not know the exact time of germination, we propose the use of dose-response models with interval censured that allow biological interpretation of parameters used to measure the germination process and reflect the experimental design of the germination data. In this work we used two methodologies of usual statistical analysis and their results were compared with those of the approach that uses the dose-response models with interval censured. We used the dose response models Weibull 2 and log-logistic to explain the process of seed germination of Brachiaria and Citrumelo Swingle with different observation times. The experiments were carried out in completely randomized design and testing procedures according to the rules for seed analysis (RAS). The conclusions obtained from the analysis of the data by the proposed methodology in general diverged from the conclusions obtained by traditional approaches (regression models nonlinear considering normal distribution and germination indices using analysis of variance) used to analyze data germination. The dose-response models with interval-censored showed satisfactory adjustments and therefore a more accurate analysis than the usual approaches.
|
434 |
Modelo matemático de distribuição larga de dose limiar em tumores submetidos a múltiplas sessões de terapia fotodinâmica / Mathematical model for broad distribution of threshold dose in tumors treated with multiple photodynamic therapy sessionsSabino, Luis Gustavo 04 February 2010 (has links)
A Terapia fotodinâmica (TFD) é uma conhecida opção terapêutica para diversos tipos de lesões malignas e não-malignas. A TFD age por meio de uma reação fotoquímica, formando agentes oxidativos que causam inúmeros danos às estruturas subcelulares e posterior morte da célula. Em grande parte dos casos são necessárias várias sessões da TFD para erradicação completa da lesão neoplásica. No entanto, vários estudos clínicos têm sido publicados mostrando recrescimento tumoral e um aumento na resistência do tumor às sessões posteriores da TFD. Neste estudo apresentamos um modelo teórico para descrever os efeitos causados por sucessivas sessões da TFD quando ocorre recrescimento tumoral. Para isso, considera-se uma distribuição de dose limiar que representa a variedade celular de um modelo teórico de tumor. A existência de uma variedade de células com diferentes doses limiares pode ser a causa de uma resposta parcial do tecido à terapia, implicando em recrescimento do tecido tumoral. Neste modelo, assume-se que esta distribuição de dose limiar é representada por uma distribuição Gaussiana modificada. Em termos de dose limiar, valores mais altos implicam em maior resistência à TFD. Se a distribuição é larga, o tratamento não é capaz de eliminar todas as células. A fração de células que sobrevivem promovem o recrescimento tumoral; no entanto, a população de células no tumor recrescido apresenta diferentes características quando comparada com a população de células do tumor original. Para avaliar a ocorrência da seleção das células mais resistentes foi realizada uma investigação sobre as alterações da resposta das células tumorais, após múltiplas sessões da terapia fotodinâmica. Para simular este tipo de procedimento foram realizadas sucessivas sessões da TFD em culturas de células de hepatocarcinoma (HepG2). Entre as sessões de TFD foi aguardado um intervalo de tempo suficiente para que as células sobreviventes se reproduzissem e formassem uma nova cultura celular. O fotossensibilizador utilizado nos experimentos foi o Photogem® e a iluminação realizada em 630 ± 10nm. Os resultados dos experimentos in vitro forneceram evidências do aumento da resistência das células neoplásicas da linhagem HepG2 após sucessivas aplicações da TFD. Este aumento é previsto pelo modelo teórico e pode estar relacionado com a variação das características da população celular, que é expressa neste modelo pela distribuição de dose limiar. No entanto, o aumento da resistência da população celular à TFD previsto pelo modelo teórico é mais acentuado do que o aumento observado no experimento com culturas celulares, portanto, mais estudos serão necessários para adequar o modelo à condição real. Com base na variabilidade das células tumorais, as simulações demonstraram que a dose de luz insuficiente pode induzir um aumento da resistência do tumor às posteriores sessões da TFD. Este modelo poderá ser utilizado para avaliar qual o tipo de distribuição de dose limiar pode-se encontrar em tumores reais e quais as conseqüências causadas pela atenuação da luz em função da profundidade do tumor. A idéia apresentada neste estudo motivará novos estudos para identificar a importância da distribuição de dose limiar em tumores submetidos à TFD. / Photodynamic therapy is a well known treatment option for many types of malignant and nonmalignant lesions. This technique causes cell damage through a photochemical reaction, generating oxidative agents responsible for tumor cell killing. In several cases, multiple PDT-sessions are needed to promote cancer eradication. However, several clinical studies have been reported an increase of tumor resistance after a PDT-session. We present a theoretical model to describe the effects caused by successive PDT sessions based on the consequences of a partial response caused by the threshold dose distribution within the hypothetical tumor. In this model, we assume that this threshold dose distribution is represented by a Modified Gaussian Distribution. In terms of threshold dose, higher values imply higher resistance to PDT. If the distribution is broad, the treatment cannot result in the killing of all tumor cells. The survival cell fraction promotes a tumor regrowth with different characteristics compared to the original cell population. We applied the model in a hypothetical tumor to exemplify the idea here presented. The qualitative analysis extracted from our theoretical model shows a behavior that is in agreement with results obtained in our results from in vitro experiments and several clinical observations. To investigate the occurrence of a selection of higher threshold dose cells, an experiment that evaluated the response of tumor cells after multiple sessions of photodynamic therapy was carried out. To simulate this procedure, successive sessions of PDT in hepatocellular carcinoma cells (HepG2) were performed. A time interval between PDT-sessions was respected to allow surviving cells division, resulting in a new cell culture. The photosensitizer used in the experiments was Photogem® and a 630 ± 10nm irradiation was performed. The result of in vitro experiments provided evidence of increasing resistance of HepG2 cells after successive PDT-sessions. This increase is predicted by the theoretical model and may be related to variations in the tumor cell population, which is expressed by the variation of the distribution of threshold dose, according to the model. However, the increased PDT resistance of the cell population provided by the theoretical model is more pronounced than the one experimentally observed. Based on tumor cell variability, the simulations demonstrated that insufficient light dose can induce an increase in tumor resistance to further PDT sessions. This model maybe used to evaluate which type of threshold dose distribution we can find in real tumors, and the consequences caused by light attenuation observed from the illuminated surface and deeper tumor regions. This proposed model shows relative agreement to clinical literature. However, further experimental observations shall improve the model here presented. The idea presented in this study shall motivate further studies to identify the importance of cell threshold distribution in tumors submitted to PDT techniques.
|
435 |
Doxorrubicina e ifosfamida em dose densa em pacientes com sarcomas de partes moles e expressão de ezrina como fator de prognóstico / Doxorrubicina e ifosfamida em dose densa em pacientes com sarcomas de partes moles e expressão de ezrina como fator de prognósticoAlmeida, Gustavo Fernandes Godoy 07 May 2010 (has links)
O prognóstico de pacientes portadores de sarcomas de partes moles (SPM) avançados é reservado. Aumentar o benefício de quimioterapia é necessário, sendo, uma das estratégias, quimioterapia em dose densa, a qual demonstrou benefício em câncer de mama. Por outro lado, a busca de um marcador prognóstico é importante para uma melhor seleção de pacientes que se beneficiariam de protocolo de tratamento mais intensivo. A ezrina é uma proteína que liga o citoesqueleto celular a proteínas de membrana, está associada a invasão celular e metástase e sua hiperexpressão tem sido associada a um pior prognóstico em sarcomas de partes moles. O objetivo deste estudo foi avaliar o papel de quimioterapia com dose densa em pacientes portadores de SPM de alto grau, avançados. O desfecho primário foi taxa de resposta e os secundários foram sobrevida global (SG), sobrevida livre de progressão (SLP), perfil de toxicidade, qualidade de vida e controle de dor. Avaliou-se também a expressão de ezrina por imunohistoquímica como marcador de prognóstico, com o intuito de estratificação da população que poderia se beneficiar mais desta abordagem intensificada. Neste estudo de fase II prospectivo, vinte e um pacientes foram incluídos. A idade mediana foi 37 anos (23-60) e extremidades inferiores foram o sítio primário mais comum. Sarcoma sinovial, leiomiossarcoma e sarcoma sem outras especificações foram as histologias mais frequentes. O protocolo consistiu de seis ciclos seqüenciais de doxorubicina 30mg/m2 D1-3 e ifosfamida 2,5g/m2 D1-5 a cada 14 e 21 dias, respectivamente, seguidos por sete dias de suporte hematopoiético. As intensidades de dose medianas de doxorrubicina e ifosfamida foram, respectivamente, 42mg/m2/semana e 3,63g/m2/semana (93% e 87% do planejado, respectivamente) e 15 pacientes (71%) receberam todo o tratamento. Toxicidades graus 3 e 4 foram observadas em 19 pacientes e em 77/105 ciclos, neutropenia febril em 6 ciclos (5 pacientes) e reduções da fração de ejeção de ventrículo esquerdo de pelo menos 10% em três pacientes. Não houve toxicidade renal provavelmente pela adminsitração da ifosfamida em duas horas. A resposta foi avaliada pelos critérios de RECIST, com três respostas parciais, totalizando uma taxa de resposta de 14%. Seis respostas deveriam ser observadas para que o estudo completasse a inclusão de todos os pacientes programados. Como não se atingiu a taxa de resposta prevista, o protocolo foi fechado. Três mortes precoces foram observadas com suspeita de toxicidade. Após seguimento mediano de 11 meses, a SLP e a SG medianas foram 8,1 e 20,1 meses respectivamente. Pacientes com sarcoma sinovial e idade inferior a 45 anos apresentaram maior sobrevida na análise univariada. A expresão de ezrina foi positiva em 10 pacientes (47%) e houve tendência a uma correlação direta entre sua expressão e sobrevida mais longa (p=0,1191). Todos os pacientes com histologia sinovial foram positivos para ezrina (teste de Fischer, p= 0,0325). Este esquema de quimioterapia sequencial com dose densa de doxorubicina e ifosfamida foi tóxico, a taxa de resposta foi baixa em um grupo de pacientes com doença avançada e não pode ser empregado na prática clínica diária fora de protocolo de pesquisa / Advanced soft tissue sarcoma (STS) patients have a dismal prognosis. Efforts to increase benefit from chemotherapy are needed and dose-dense chemotherapy could be an option, since this approach has demonstrated survival benefit in breast cancer. On the other hand, the identification of a prognostic marker is essential to stratify which patients could benefit most from intensified strategies. Ezrin is a member of the ERM (ezrin, radixin, moesin) cytoeskeleton-associated protein family associated with invasion and metastasis, and has been pointed as important prognostic marker in sarcomas. The objective of this study was to explore the role of dose-dense doxorubicin- and ifosfamide-based chemotherapy in advanced high grade STS patients. Primary endpoint was response rate and secondary endpoints were overall survival (OS), progression free survival (PFS), toxicity profile, quality of life and pain control evaluation. Tumor ezrin immunoreactivity was an exploratory endpoint as a predictor of response to chemotherapy and as a prognostic factor in this population, trying to find which patients could benefit most from this intensified strategy. This prospective, single arm, phase II study included 21 advanced STS patients. Median age was 37 years (23-60y) and lower limbs were the most frequent primary site. Synovial, leiomyo and unclassified sarcoma were the most common histologies. Protocol consisted of 6 cycles of sequential dose-dense doxorubicin 30 mg/m2 D1-3 and ifosfamide 2.5 g/m2 D1-5 every 14 and 21 days, respectively, followed by seven days of hematopoietic support. The median doxorubicin and ifosfamide dose-intensities were, respectively, 42 mg/m2/week and 3.63 g/m2/week (93% and 87% of planned, respectively) and 15 patients (71%) received all cycles. Grade 3/4 toxicities occurred in 19 patients and 77/105 cycles, febrile neutropenia in 5 patients (six cycles) and three LVEF drops of at least 10%, one symptomatic. No renal toxicity was observed what could occurred due to the two-hour-schedule of ifosfamide. Responses were evaluated by RECIST criteria and three patients presented partial response (response rate of 14%). Six responses were necessary to the inclusion of the target population, however, this was not observed and the study was closed. Three deaths were probably related to toxicity. After a median follow-up was 11 months, PFS and OS were 8.1 months and 20.1 months, respectively. Patients with synovial sarcoma and those younger than 45y presented better survival at univariate analysis. Ezrin expression was positive in 10 patients (47%) and a trend was observed for a correlation between positive ezrin expression and longer survival (p= 0.1191). There was a statistically significant correlation between positive ezrin expression and synovial hystology (Fishers exact test, p= 0.0325). This sequential dosedense doxorubicin/ifosfamide-based chemotherapy protocol was toxic, response rate was low in advanced STS patients and can not be considered for routine practice outside clinical trials
|
436 |
Algoritmo de reconstrução de dose a partir de mapas portais de dose utilizando simulação Monte Carlo / Dose reconstruction algorithm from portal dose maps using Monte Carlo simulationRodrigues, Eduardo de Matos 15 October 2014 (has links)
Electronic Portal Image Devices (EPID) são dispositivos eletrônicos que foram criados originalmente para aquisição de imagens portais. Atualmente eles também têm sido estudados para reconstrução de dose no plano do eixo central (paralelo ao EPID) na modalidade transit (modalidade que considera um material atenuador entre a fonte e o EPID). Neste trabalho foi determinado um algoritmo de reconstrução de dose para relacionar mapas bidimensionais de dose localizados dentro de geometrias que simularam uma situação clínica em radioterapia de forma simplificada. Para tal foram feitas simulações Monte Carlo utilizando o pacote de simulação PENELOPE de maneira que um cubo composto de água representou o corpo do paciente e um paralelepípedo retângulo composto de água representou o EPID. Definiu-se primeiramente a geometria controle e os parâmetros de irradiação controle e então foram feitas simulações para determinar a equação de reconstrução de dose referencial. Uma vez determinada essa equação, foram feitas novas simulações variando o tamanho de campo, espessura do objeto simulador do corpo, distância entre a fonte e a superfície de entrada do objeto simulador do corpo (DFS) e distância entre a superfície de saída do objeto simulador do corpo e o centro do objeto simulador do EPID (DSDE). Os arquivos de saída dessas simulações alimentaram o programa contendo o algoritmo de reconstrução de dose, feito em MATLAB®. Após a aplicação do programa, comparou-se a matriz que representa o mapa bidimensional localizado dentro do objeto simulador do corpo com a matriz localizada no mesmo local, reconstruída a partir da matriz que representa o objeto simulador do EPID. Os resultados encontrados neste trabalho mostram que a equação de reconstrução de dose e o algoritmo de reconstrução de dose propostos são válidos com desvios padrão menor que 1,6%. / Electronic Portal Image Devices (EPID) were originally created to acquire portal images, but they have also been studied for dose reconstruction in the central axis plane (parallel to the EPID) in transit mode (mode which considers an attenuator material between the source and the EPID). In this work we determined a dose reconstruction algorithm that relate two-dimensional dose maps located within geometries that simulated a clinical situation in simplified form. For this, simulations were performed using the simulation package PENELOPE so that a cube composed of water represented the patients body and a rectangle parallelepiped composed of water represented the EPID. We defined a control geometry and control irradiation parameters first, then simulations were performed to determine the referential dose reconstruction equation. Once determined this equation, new simulations were performed varying the field size, the body phantom thickness, the distance between the source and the body phantom entrance surface (DFS) and the distance between the body phantom exit surface and the EPID phantom center. The output files of these simulations fed the program containing the dose reconstruction algorithm, wrote in MATLAB®. After the program application, we compared the matrix that represents the two-dimensional map located within the body phantom with the matrix located at the same site, reconstructed from the matrix that represents the EPID phantom. The results in this work show that the dose reconstruction equation and the dose reconstruction algorithm proposed are valid with less than 1,6% standard deviation.
|
437 |
Hemodiálise prolongada na lesão renal aguda associada a sepse sobrevida dos pacientes de acordo com o momento da indicação e a dose de diálise recebida /Abrão, Juliana Maria Gera January 2016 (has links)
Orientador: André Luís Balbi / Resumo: Introdução - A mortalidade de pacientes com Lesão Renal Aguda (LRA) que necessitam de suporte renal agudo (SRA) é elevada. Alguns estudos sugerem que o SRA indicado tardiamente associa-se a piores desfechos. Outros, avaliando dose de diálise, não encontraram benefício com uso de SRA mais intenso. Entretanto, são escassos os trabalhos que avaliaram estes tópicos em pacientes dialisados por Hemodiálise Prolongada (HDP) e considerando a LRA exclusivamente associada a sepse. Objetivo - Avaliar a sobrevida de pacientes com LRA associada a sepse, submetidos a HDP, de acordo com o momento da indicação e a dose de diálise recebida. Material e Métodos - Coorte retrospectiva de pacientes críticos com LRA associada a sepse, estágio 3 segundo classificação AKIN, submetidos a HDP, de abril de 2008 a outubro de 2014, em dois hospitais de referência em nefrologia. De acordo com o momento da indicação do SRA, os pacientes foram divididos em grupo SRA precoce (início até 24 horas após atingido estágio 3 da LRA) e SRA tardio (início depois de 24 horas após atingido estágio 3 da LRA). A dose de diálise obtida por sessão foi calculada e, de acordo com a média do Kt/V semanal recebido, os pacientes também foram divididos em grupo SRA intenso (Kt/V maior ou igual a média) e grupo SRA menos intenso (Kt/V menor que a média). O desfecho estudado foi mortalidade intra-hospitalar. Considerado nível de significância de 5%. Resultados - Foram estudados 361 pacientes, com média de idade de 59,7 ± 15,7 ano... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Introduction - The mortality of patients with Acute Kidney Injury (AKI) requiring Acute Renal Support (ARS) is high. Some studies suggest that ARS indicated lately is associated with worse outcomes. Other, assessing dialysis dose, found no benefits with an intense use of ARS. However, few studies assessed those topics in dialyzed patients under extended hemodialysis and considering the Acute Kidney Injury exclusively associated with sepsis. Objective - To assess survival in patients with AKI associated with sepsis subject to extended hemodialysis according to the time of prescription and dialysis dose received. Material and Methods - Retrospective cohort of critically ill patients with AKI associated with sepsis, stage 3, according to AKIN classification, subjected to extended hemodialysis, from April 2008 to October 2014, in two referral hospitals in nephrology. According to the time of ARS indication patients were divided into early ARS group (beginning within 24 hours of reaching Stage 3 of AKI) and late ARS (beginning after 24 hours of reaching Stage 3 of AKI). Dialysis dose obtained by session was calculated and according to the average of weekly Kt/V received, patients were also divided into heavy ARS group (Kt/V ≥ average) and less intense ARS group (Kt/V < average). The study outcome was in-hospital mortality, considering a significance level of 5%. Results - 361 patients were studied aged between 59.7 ± 15.7 years old and 65.6% men. In AKI AKIN 3 diagnosis, 62.1% pre... (Complete abstract click electronic access below) / Doutor
|
438 |
Estudo clínico comparativo de dose única pré-operatória de 50mg de rofecoxib ou diclofenado sódico no controle da dor após tratamento endodônticoRoderjan, Douglas Augusto 30 July 2004 (has links)
Made available in DSpace on 2017-07-24T19:22:26Z (GMT). No. of bitstreams: 1
Douglas Augusto Roderjan.pdf: 1097891 bytes, checksum: 0cf3a0755667f71c73885630393d0914 (MD5)
Previous issue date: 2004-07-30 / Pain management following endodontic therapy is an essential part of patient treatment.
Nonsteroidal anti-inflammatory drugs (NSAIDs) inhibit cyclooxygenase enzymes that
abolish the effects of prostaglandins and consequently exert potent anti-inflammatory
and analgesic activity. The aim of the present pilot study was to test the efficacy of prior
drug administration in the control of postoperative pain following endodontic therapy.
Informed consent was obtained prior to their participation. Sixty patients requiring
endodontic therapy for asymptomatic anterior teeth were randomly assigned to to three
randomized groups. Treatment groups did not significantly differ (p > 0.05). Prepared
capsules of a single dose of placebo (n=20), rofecoxib 50mg (a COX-2 selective
inhibitor; n=20) or diclofenac 50 mg (a non-specific COX inhibitor; n=20) were
administered 30 min before dental treatment. All endodontic therapies were completed
using an anaesthetic volume ≤ 1,8ml. There were no statistically significant differences
in volume of local anesthetic used (p=0.89) or duration of the operation
proccedure(p=0.69). Pain intensity was evaluated by a 100mm Visual Analogical Score
(VAS) and Visual Color Categorical Score (VCCS) at 0, 4, 6, 8, 10, 12 and 24 hours
after NSAIDs or placebo administration by repeated measures ANOVA. It adds sum of
pain intensity differences (SPID) it was evaluated by ANOVA in the experimental times
4,6,8,10,12 and 24 hours multiplying the score difference with the baseline for the
respective experimental time and adding cumulatively with the values obtained in the
previous times. Medication consumption supports and pain intensity through the
frequency of the percentages among the groups was analyzed through the qui-square
test for evaluation of tendencies at 5% signifcance level. Repeated measures ANOVA
of the pain intensity obtained through the analogical visual scale indicated a difference
among the treatments (p=0,08). The patient percentage reporting VAS≥23 mm in the
placebo was significant (p<0,0001) in the periods between the octave and tenth-second
hour. Summed pain intensity differences (SPID) it demonstrated that rofecoxib 50 mg
administered pre-operatory was effective in the control of the pain (p <0,0001) versus
placebo. This effect was important for SPID-10, SPID-12 e SPID-24. The sodic
diclofenac 50 mg group it was not different from the placebo, although a smaller pain
level has been observed in that group in the initial periods of time and in the tenth and
tenth-second hour of the experimentation. Reports of collateral effects were not
observed by the patients in the different times and experimental groups. After 24 hours
of the experimentation, it was not told need of support medication use. These results
suggest that single a pre-operatory dose of the cyclooxygenase inibitors tested may be
sufficient to prevent post-endodontic pain. / O controle da dor após terapia endodôntica é uma essencial fase do tratamento clínico.
Antiinflamatórios não-esteroidais (AINEs) atuam no sistema enzimático da via
ciclooxigenase (COX) inibindo ou reduzindo o aparecimento das prostaglandinas e
demais mediadores químicos endógenos, conseqüentemente exercendo potente
atividade antiinflamatória e analgésica. Esse estudo teve como objetivo principal testar
a eficácia da administração pré-operatória de AINEs no controle da dor após tratamento
endodôntico. O estudo iniciou-se com a devida aprovação no Comitê de ética em
pesquisa e consentimento pós-informação de todos os pacientes da amostra. Sessenta
pacientes necessitando terapia endodôntica em dentes assintomáticos monoradiculares
foram distribuídos em três grupos. Não foram observadas diferenças estatística
significantes nos grupos experimentais (p > 0,05). Cápsulas foram especialmente
preparadas para as doses únicas de Placebo (n=20), Rofecoxib 50mg (inibidor seletivo
da COX-2 (n=20) ou Diclofenaco sódico 50 mg (inibidor não-específico da COX (n=20).
Foram administradas 30 minutos antes do tratamento endodôntico. Todas as terapias
endodônticas foram completadas com um volume de anestésico ≤ 1,8 ml. Não
ocorreram diferenças estatisticamente significantes no volume de anestésico local
utilizado (p=0.89) ou duração do procedimento endodôntico (p = 0.69). Intensidade de
dor foi avaliada através da escala visual analógica de 100 mm (EVA) e escala visual
colorida através de medidas repetidas de Análise de Variância (ANOVA), nos tempos 0,
4, 6, 8, 10, 12 e 24 horas após a administração dos AINEs ou placebo. Soma das
diferenças de intensidade de dor (SDID) foi avaliada por ANOVA nos tempos
experimentais 4,6,8,10,12 e 24 horas multiplicando-se a diferença de escore com o
baseline pelo respectivo tempo experimental e somando acumulativamente com os
valores obtidos nos tempos anteriores. Consumo de medicação suporte e intensidade
de dor através da freqüência das porcentagens entre os grupos foram analisadas
através do teste de qui-quadrado para avaliação de tendências ao nível de significância
de 5%. ANOVA da intensidade de dor obtida através da escala visual analógica indicou
uma diferença entre os tratamentos (p = 0,08). A porcentagem de pacientes reportando
EVA ≥ 23 mm no grupo placebo foi estatisticamente significante (p < 0,0001) nos
períodos compreendidos entre a oitava e décima-segunda hora.A soma das diferenças
de intensidade de dor (SDID) demonstrou que rofecoxib 50 mg administrado préoperatoriamente
foi efetivo no controle da dor (p < 0,0001) versus o grupo de pacientes
que receberam placebo.Esse efeito foi importante para SDID-10, SDID-12 e SDID-24.O
grupo de pacientes que recebeu diclofenaco 50 mg não foi diferente do grupo placebo,
embora tenha sido observado um menor nível de dor nesse grupo nos períodos de
tempo iniciais e na décima e décima-segunda hora da experimentação. Não foram
observados relatos de efeitos colaterais pelos pacientes nos diferentes tempos e grupos
experimentais.Após as 24 horas da experimentação, não foi relatado necessidade de
uso de medicação suporte. Esses resultados sugerem que uma única dose préoperatória
dos inibidores da ciclooxigenase testados pode ser suficiente para prevenir a
dor pós-endodôntica.
O controle da dor após terapia endodôntica é uma essencial fase do tratamento clínico.
Antiinflamatórios não-esteroidais (AINEs) atuam no sistema enzimático da via
ciclooxigenase (COX) inibindo ou reduzindo o aparecimento das prostaglandinas e
demais mediadores químicos endógenos, conseqüentemente exercendo potente
atividade antiinflamatória e analgésica. Esse estudo teve como objetivo principal testar
a eficácia da administração pré-operatória de AINEs no controle da dor após tratamento
endodôntico. O estudo iniciou-se com a devida aprovação no Comitê de ética em
pesquisa e consentimento pós-informação de todos os pacientes da amostra. Sessenta
pacientes necessitando terapia endodôntica em dentes assintomáticos monoradiculares
foram distribuídos em três grupos. Não foram observadas diferenças estatística
significantes nos grupos experimentais (p > 0,05). Cápsulas foram especialmente
preparadas para as doses únicas de Placebo (n=20), Rofecoxib 50mg (inibidor seletivo
da COX-2 (n=20) ou Diclofenaco sódico 50 mg (inibidor não-específico da COX (n=20).
Foram administradas 30 minutos antes do tratamento endodôntico. Todas as terapias
endodônticas foram completadas com um volume de anestésico ≤ 1,8 ml. Não
ocorreram diferenças estatisticamente significantes no volume de anestésico local
utilizado (p=0.89) ou duração do procedimento endodôntico (p = 0.69). Intensidade de
dor foi avaliada através da escala visual analógica de 100 mm (EVA) e escala visual
colorida através de medidas repetidas de Análise de Variância (ANOVA), nos tempos 0,
4, 6, 8, 10, 12 e 24 horas após a administração dos AINEs ou placebo. Soma das
diferenças de intensidade de dor (SDID) foi avaliada por ANOVA nos tempos
experimentais 4,6,8,10,12 e 24 horas multiplicando-se a diferença de escore com o
baseline pelo respectivo tempo experimental e somando acumulativamente com os
valores obtidos nos tempos anteriores. Consumo de medicação suporte e intensidade
de dor através da freqüência das porcentagens entre os grupos foram analisadas
através do teste de qui-quadrado para avaliação de tendências ao nível de significância
de 5%. ANOVA da intensidade de dor obtida através da escala visual analógica indicou
uma diferença entre os tratamentos (p = 0,08). A porcentagem de pacientes reportando
EVA ≥ 23 mm no grupo placebo foi estatisticamente significante (p < 0,0001) nos
períodos compreendidos entre a oitava e décima-segunda hora.A soma das diferenças
de intensidade de dor (SDID) demonstrou que rofecoxib 50 mg administrado préoperatoriamente
foi efetivo no controle da dor (p < 0,0001) versus o grupo de pacientes
que receberam placebo.Esse efeito foi importante para SDID-10, SDID-12 e SDID-24.O
grupo de pacientes que recebeu diclofenaco 50 mg não foi diferente do grupo placebo,
embora tenha sido observado um menor nível de dor nesse grupo nos períodos de
tempo iniciais e na décima e décima-segunda hora da experimentação. Não foram
observados relatos de efeitos colaterais pelos pacientes nos diferentes tempos e grupos
experimentais.Após as 24 horas da experimentação, não foi relatado necessidade de
uso de medicação suporte. Esses resultados sugerem que uma única dose préoperatória
dos inibidores da ciclooxigenase testados pode ser suficiente para prevenir a
dor pós-endodôntica.
|
439 |
Dosimétrie neutron en radiothérapie : étude expérimentale et développement d'un outil personnalisé de calcul de dose Monte Carlo / Neutron dosimetry in radiotherapy : experimental study and Monte Carlo personalised dose calculation tool developmentElazhar, Halima 07 September 2018 (has links)
L’optimisation des traitements en radiothérapie vise à améliorer la précision de l’irradiation des cellules cancéreuses pour épargner le plus possible les organes environnants. Or la dose périphérique déposée dans les tissus les plus éloignés de la tumeur n’est actuellement pas calculée par les logiciels de planification de traitement, alors qu’elle peut être responsable de l’induction de cancers secondaires radio-induits. Parmi les différentes composantes, les neutrons produits par processus photo-nucléaires sont les particules secondaires pour lesquelles il y a un manque important de données dosimétriques. Une étude expérimentale et par simulation Monte Carlo de la production des neutrons secondaires en radiothérapie nous a conduit à développer un algorithme qui utilise la précision du calcul Monte Carlo pour l’estimation de la distribution 3D de la dose neutron délivrée au patient. Un tel outil permettra la création de bases de données dosimétriques pouvant être utilisées pour l’amélioration des modèles mathématiques « dose-risque » spécifiques à l’irradiation des organes périphériques à de faibles doses en radiothérapie. / Treatment optimization in radiotherapy aims at increasing the accuracy of cancer cell irradiation while saving the surrounding healthy organs. However, the peripheral dose deposited in healthy tissues far away from the tumour are currently not calculated by the treatment planning systems even if it can be responsible for radiation induced secondary cancers. Among the different components, neutrons produced through photo-nuclear processes are suffering from an important lack of dosimetric data. An experimental and Monte Carlo simulation study of the secondary neutron production in radiotherapy led us to develop an algorithm using the Monte Carlo calculation precision to estimate the 3D neutron dose delivered to the patient. Such a tool will allow the generation of dosimetric data bases ready to be used for the improvement of “dose-risk” mathematical models specific to the low dose irradiation to peripheral organs occurring in radiotherapy.
|
440 |
Método baseado em médias não-locais para filtragem do ruído quântico de imagens mamográficas digitais adquiridas com dose de radiação reduzida / Method based on the non-local means for quantum noise filtering in digital mammography images acquired with reduced radiation dosePolyana Ferreira Nunes 26 August 2016 (has links)
Esse trabalho apresenta uma nova proposta do algoritmo de médias não-locais (NLM - Non-Local Means) para a filtragem do ruído quântico de imagens mamográficas digitais adquiridas com dose de radiação reduzida. A redução nas doses de radiação tem como objetivo principal minimizar os riscos de indução ao câncer de mama causado pela exposição do paciente à radiação ionizante no momento do exame. No entanto, a qualidade da imagem mamográfica diminui com a redução da dose de radiação e o ruído predominante nesse caso é o ruído quântico, que segue a distribuição de Poisson e é dependente do sinal. Como o algoritmo NLM foi originalmente desenvolvido para filtragem de ruído Gaussiano independente do sinal, a proposta desse trabalho foi de adaptar o algoritmo NLM original de modo que ele se tornasse mais adequado para filtragem do ruído encontrado nas imagens mamográficas digitais. Nessa nova abordagem, chamada de Variance Map Non-local Means (VM-NLM), a filtragem do ruído quântico é realizada no próprio domínio da imagem, levando-se em conta a variância do ruído em cada pixel da imagem, já que o ruído é dependente do sinal. Com isso, elimina-se a necessidade de realizar uma estimativa precisa dos parâmetros do ruído para o uso de uma transformada de estabilização de variância (como a transformada generalizada de Anscombe), antes do processo de filtragem. Essa estimativa normalmente requer medidas preliminares no equipamento mamográfico, cujo acesso nem sempre é viável na prática. A proposta foi avaliada em três bancos de imagens mamográficas adquiridas com diferentes doses de radiação. As avaliações de desempenho foram realizadas comparando objetivamente a qualidade das imagens mamográficas obtidas com a dose padrão de radiação com as adquiridas com doses reduzidas, após a filtragem do ruído. Os resultados obtidos com o algoritmo proposto mostraram que ele produz imagens mamográficas mais nítidas e com melhor preservação de bordas e pequenos detalhes do que o algoritmo NLM original. / This work presents a new proposal from the non-local means algorithm (NLM - Non-Local Means) for filtering the quantum noise of digital mammography images acquired with reduced radiation dose. The reduction in radiation doses aims to minimize the risk of inducing breast cancer caused by patient exposure to ionizing radiation during the examination. However, the mammographic image quality decreases with the reduction of the radiation dose and the predominant noise in this case is the quantum noise, which follows the Poisson distribution and it is dependent of the signal. As the NLM algorithm was originally developed for filtering additive Gaussian noise, the purpose of this study was to adapt the original NLM algorithm so that it becomes more suitable for filtering the noise found in digital mammographic images. In this new approach, called Variance Map Non-local Means (VM-NLM), the filtering of the quantum noise is performed in the image domain, considering the noise variance in each pixel of the image, since the noise depends on the pixel value. Thus, it eliminates the need for an accurate estimate of the noise parameters for the use of a variance stabilization transform (such as generalized Anscombe Transformation) before the filtering process. This estimate typically requires preliminary measurements in the mammographic equipment, which is not always viable in clinical practice. The proposal was evaluated in three databases of mammographic images acquired with different radiation doses. Performance evaluations were conducted comparing objectively the quality of mammographic images acquired with standard radiation dose and with reduced doses, after filtering the noise. The results obtained with the proposed algorithm showed that it produces sharper mammographic images with better preservation of edges and small details than the original NLM algorithm.
|
Page generated in 0.1039 seconds