• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • 2
  • 1
  • Tagged with
  • 34
  • 18
  • 15
  • 14
  • 13
  • 11
  • 9
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Análise teórica e experimental do comportamento de modelos de pilares esbeltos de concreto de alta resistência, considerando a ductilidade / Theoretical and experimental analysis of slender high-strength concrete columns, considering the ductility

Francisco Aguirre Torrico 22 February 2010 (has links)
Esta tese discute as análises teórica e experimental de pilares de seção retangular, esbeltos, confinados por estribos, de concreto de alta resistência, sujeitos à flexo-compressão, considerando os estados limites últimos de ruptura do concreto ou por deformação excessiva das barras da armadura ou por instabilidade. Foram ensaiados 12 modelos de pilares com esbeltez mecânica igual a 92, compondo três séries de 4 pilares cada uma; os parâmetros estudados foram a excentricidade da força, a taxa volumétrica de armadura transversal e a resistência do concreto. Em uma segunda fase, foram analisados 9 pilares curtos de seção quadrada à compressão concêntrica com o objetivo de avaliar a ductilidade e obter as propriedades do concreto confinado. Para a realização dos ensaios foram empregadas rótulas unidirecionais, que permitiram transferir a força excêntrica ao pilar. Para a obtenção das resistências dos concretos, foram realizados ensaios para a determinação da composição dos materiais e foram traçadas curvas de dosagem. Os resultados experimentais foram comparados com os obtidos com o método exato que considera a não linearidade física e geométrica por meio de programas computacionais elaborados pelo autor. Observou-se que os resultados experimentais se aproximaram dos resultados teóricos. As ruínas dos pilares esbeltos foram por instabilidade, sendo que todos eles atingiram o ponto limite. Foi verificado que a capacidade resistente dos pilares é muito sensível para pequenas variações da excentricidade da força. Nos modelos analíticos foram incorporadas formulações de várias normas que contemplam concretos de alta resistência e o critério de confinamento indicadas pela literatura técnica com algumas modificações. Foi verificada uma pequena melhora na ductilidade ao incrementar a taxa de armadura transversal dos modelos ensaiados. Com os resultados obtidos e com as formulações analisadas, sugere-se uma forma alternativa de projeto de pilares esbeltos. / This thesis discusses the theoretical and experimental analyses of slender high-strength concrete rectangular columns confinement by lateral reinforcement, subjected to combined axial load and bending, considering the ultimate limit states of concrete crushing at the compressive face or the longitudinal bars excessive deformation or the column instability. Twelve column models were tested with 92 mechanical slenderness. These models included three series of four columns each; the parameters studied were axial load eccentricity, volumetric lateral reinforcement ratio and concrete strength. In a second step, nine square cross section short columns under concentric compression were tested to evaluate ductility and to obtain the confined concrete properties. A pair of unidirectional hinges was used to transfer the eccentric load to the columns. Tests were carried out for material\'s composition determination and dosage curves were drawn to obtain concrete strengths. The experimental results were compared with those obtained using the exact method that considers physical and geometrical nonlinearities through computational programs prepared by the author. There is not a significant difference between experimental and theoretical results. The instability failure was reach in all columns because of high slenderness, all of they reached the limit point. It was observed that the column ultimate strength is very sensitive for small axial load eccentricity variations. The formulations of several standards codes that consider the high-strength concrete and technical literature confinement criterion with some modifications have been incorporated in the analytical models. A small ductility improvement was observed considering the tests volumetric lateral reinforcement ratio increase. There is an alternative method suggested for slender columns design, based on the obtained results.
22

[en] EXPERIMENTAL STUDY ON DUCTILITY OF REINFORCED CONCRETE BEAMS STRENGTHENED IN FLEXURE WITH CARBON FIBER COMPOSITES / [pt] ESTUDO EXPERIMENTAL DA DUCTILIDADE DE VIGAS EM CONCRETO ARMADO REFORÇADAS À FLEXÃO UTILIZANDO COMPÓSITOS COM TECIDO DE FIBRAS DE CARBONO

MARCELIA GOMES MACHADO 12 January 2005 (has links)
[pt] Este trabalho experimental tem como objetivo estudar a ductilidade de vigas retangulares de concreto armado reforçadas à flexão utilizando compósitos com tecido de fibras de carbono. No estudo realizado são apresentados os conceitos clássicos de ductilidade e é proposta uma nova sistemática para obtenção do índice de ductilidade, baseada nas considerações da energia elástica e da energia inelástica. A ductilidade é determinada por meio de um índice energético, que se caracteriza como uma forma mais eficiente para a determinação e análise da ductilidade em elementos estruturais. O programa experimental consistiu no ensaio de sete vigas bi-apoiadas, sendo uma viga de referência e as demais reforçadas à flexão com tecido de fibras de carbono. Todas as vigas possuem as mesmas características mecânicas e geométricas e foram dimensionadas de modo a garantir a ruptura por flexão. A viga de referência, a primeira ensaiada, não foi reforçada e serviu para comparações de incremento de rigidez e resistência após a aplicação do reforço. As vigas reforçadas foram divididas em dois grupos. O grupo A é constituído de duas vigas, reforçadas inicialmente com uma e duas camadas de tecido de fibra de carbono. O grupo B é constituído por quatro vigas que foram reforçadas após um carregamento inicial. Neste grupo, duas vigas foram reforçadas com uma camada de tecido de fibra de carbono e as outras duas foram reforçadas com duas camadas de tecido de fibras de carbono, correspondendo à mesma área total de reforço das anteriores. Todas as vigas foram concretadas, instrumentadas e ensaiadas no Laboratório de Estruturas e Materiais da PUC-Rio. Os ensaios das vigas do grupo B foram realizados com as vigas pré-ensaiadas, reforçadas sob deformação constante e em seguida levadas à ruptura. A deformação foi mantida constante durante a aplicação e o período de cura do reforço. Os resultados obtidos em termos de carga, flecha, momento, curvatura, ductilidade energética e rotação plástica foram analisados. Os estudos realizados mostraram que o reforço com compósitos de fibras de carbono é uma técnica eficaz, que as vigas apresentam ductilidade adequada e que os índices energéticos propostos são adequados para este tipo de estudo. / [en] The objective of this experimental work is to study the ductility of reinforced concrete beams strengthened in flexure using externally bonded carbon fiber fabric composites. This study presents the classic concepts of ductility and proposes a new systematic to obtain the ductility index, which is based on the considerations of elastic and inelastic energy. The ductility was determined by an energetic index, which has seen to be a more efficient method to establish and analyze the ductility of structural elements. The experimental program consisted of seven beams tests. One was used as a control beam without external reinforcement and the others were strengthened with carbon fibers in order to resist flexural load. All the beams had the same mechanical and geometrical characteristics and were designed to fail in flexure. The control beam was not strengthened and its purpose was to compare the stiffness increase and resistance after the strength. The strengthened beams were divided in two groups. Group A was constituted by two beams, initially strengthened by one and two layers of carbon fiber fabric. Group B was formed by four beams which were strengthened after the application of an initial load. In this group, two beams were strengthened by one layer of carbon fiber fabric and the other two were strengthened by two layers, which corresponded to the same area of the others. All the beams were cast, instrumented and tested in the Structural and Materials Laboratory at PUC-Rio. Group B tests were performed with the pretested beams strengthened under constant strain, and then loaded up to rupture. The strain was kept constant during the application and cure of the external reinforcement. The results obtained in terms of load, deflection, resistant moment, curvature, energetic ductility indexes and plastic rotation were analyzed. The study showed that the reinforcement using carbon fiber fabric composites is an efficient technique, the beams presented adequate ductility and the proposed energetic ductility indexes are consistent formulae for this kind of study.
23

Influência do confinamento na resistência e ductilidade de pilares curtos de concreto de ultra alta resistência submetidos à compressão centrada / Influence of confinement on strength and ductility of short ultra high strength concrete columns subjected to compressive force

Viapiana, Lincoln Grass 17 March 2016 (has links)
Neste estudo foram analisados experimentalmente o comportamento de 24 pilares curtos de Concreto de Ultra Alta Resistência - CUAR, confinados por armaduras helicoidais, avaliando especificamente os acréscimos de resistência e ductilidade obtidos com diferentes níveis de pressão lateral de confinamento. Na etapa experimental foram realizados ensaios de pilares curtos de CUAR com as seguintes características: - seção circular de 7,2 cm de diâmetro e comprimento de 23 cm, e quatro níveis de resistência à compressão do concreto sendo eles, 165, 175, 200 e 229 MPa, dosados sem e com adição de fibras metálicas; - diferentes espaçamentos das armaduras helicoidais, de modo que fossem obtidas situações com baixo, médio e alto índice de confinamento e taxa de armadura longitudinal fixa. Os ensaios de compressão centrada foram realizados com controle de deslocamento, de modo que foram obtidas as curvas força x deslocamento completas. Constatou-se que a seção resistente dos pilares de CUAR é a formada pelo núcleo de concreto confinado, área delimitada pelo eixo da armadura transversal. Observou-se que o CUAR com fibras metálicas apresenta maior deformação do núcleo de concreto confinado em relação ao núcleo de concreto confinado de CUAR sem adição de fibras metálicas, indicando dessa forma, que os pilares de CUAR com fibras metálicas apresentam comportamento mais dúctil. Para as situações de alto confinamento foram gerados ao concreto do núcleo confinado significativos acréscimos de resistência e deformação axial, aumentando a resistência do concreto confinado em relação a resistência do concreto não confinado em: 82,26%, 75,34%, 90,46% e 70,51%, respectivamente, e as deformações axiais do concreto confinado em relação a deformação axial do concreto não confinado em: 433%, 474%, 647% e 550%. Finalmente, acredita-se que os resultados obtidos poderão trazer subsídios para aplicações futuras desta técnica de confinamento na construção de novos elementos estruturais e no reforço de pilares submetidos a elevados níveis de solicitação axial. / This study evaluated experimentally the behavior of 24 short columns of Ultra High Strength Concrete - UHSC confined by helical transverse reinforcement, specifically evaluating strength increases and ductility obtained with different levels of lateral pressure of confinement. In the experimental phase short UHSC columns with the following characteristics were tested: - circular cross section of 7.2 cm diameter and 23 cm length, four levels of concrete strength (165, 175, 200 and 229 MPa), with and without addition of metallic fibers; - different spacing of transverse reinforcement, so that situations were obtained with low, medium and high level of confinement, while the longitudinal reinforcement ratio was fixed. The centered compression tests were conducted with displacement control, so that complete force x displacement curves were obtained. It was found that the resistant section of UHSC columns is formed by the confined concrete core delimited by the axis of the transverse reinforcement. It was observed that the axial displacement reached in columns with steel fibers was higher than without fibers, indicating that columns with steel fibers exhibit more ductile behavior. For high confinement levels significant axial strength and displacement increases were observed. Increases of axial strength of confined concrete in comparison to unconfined concrete were 82.26%, 75.34%, 90, 46% and 70.51%. Axial displacements were increased by 433%, 474%, 647% and 550%. Finally, it is believed that the results could provide information for future applications of this technique in construction of a new type of columns or in strengthening of columns subjected to high levels of axial force.
24

Estudo teórico-experimental de pilares mistos compostos por tubos de aço preenchidos com concreto de alta resistência. / Theoretical and experimental study of high strength concrete filled steel tubes

De Nardin, Silvana 25 March 1999 (has links)
O emprego de pilares mistos formados por tubos de aço preenchidos com concreto de alta resistência, sobretudo em edifícios altos, é uma tendência em diversos países europeus, americanos e asiáticos. A tais elementos são atribuídas vantagens como: alta resistência e ductilidade, economia de materiais e mão-de-obra, redução das dimensões da seção transversal e melhoria no comportamento dos materiais aço e concreto, devido ao efeito de confinamento. Buscando suprir algumas carências de conhecimento, procura-se obter dados experimentais sobre o comportamento de pilares mistos axialmente comprimidos, possibilitando desta forma avaliar parâmetros como influência da forma da seção transversal e da espessura do perfil tubular no seu comportamento. Foram analisadas seções quadradas, circulares e retangulares, preenchidas por concreto com resistência média de 50MPa. A ruína destes elementos caracterizou-se pelo esmagamento do concreto, ocorrendo posteriormente a flambagem local do perfil em diversos pontos. A capacidade resistente prevista por diversas normas resultou em valores muito próximos dos experimentais, embora várias destas normas não considerem o efeito de confinamento. Os ensaios mostraram que o efeito de confinamento contribui de forma decisiva na melhoria do comportamento dos materiais, sobretudo ductilizando o concreto de alta resistência, entretanto seus efeitos não são significativos no aumento da capacidade resistente da seção mista. Alguns critérios para avaliação da ductilidade à compressão foram adaptados e mostraram bons resultados, possibilitando o cálculo do índice de ductilidade. / The use of concrete filled steel tubes especially in tall buildings is a tendency in several european, american and asian countries. The use of these members has several advantages: high resistance and ductility, saving of materials and labour, reduction of cross section dimensions and improvement in behaviour of the materials steel and concrete due the confinement. The main purpose of this study is provide some experimental results of the behaviour of concrete filled steel tubes concentrically loaded. The main experimental parameters considered were the influence of the cross-section shape and thickness of steel tube. Square, circular and rectangular cross-section shapes infilling with concrete of the 50MPa of strength were analyzed. The failure was characterized for crushing of the concrete and later local buckling of the steel section in several points. The strength capacity predicted for several standards showed good agreement with the experimental failure values although this does not consider the confinement of the concrete. The results of tests showed that the confinement effect contributes for improvement behaviour of materials, especially increasing the ductility of the high strength concrete. However the results showed that the triaxial confinement does not increase the axial capacity of the concrete filled steel tubes. Some methods to estimate the ductility of axially compressed concrete columns were adapted and showed good results permitting the calculation of the ductility index of short columns.
25

Influência da forma de seção transversal no confinamento de pilares de concreto armado encamisados com PRFC (polímero reforçado com fibras) / Influence of the cross section shape in the confinement of jacketed reinforced concrete columns with CFRP (carbon fiber reinforced polymer)

Sudano, Alexandre Luis 31 May 2005 (has links)
O efeito de confinamento do concreto em pilares submetidos à compressão axial traz diversos benefícios ao seu comportamento estrutural, dentre os quais destacam-se o aumento na resistência à compressão axial do concreto pela ação das pressões laterais, e a melhoria da ductilidade do elemento estrutural. Em função destas vantagens, o confinamento é uma das principais técnicas de reforço de pilares de concreto. Porém, dependendo da forma da seção transversal, a eficiência do reforço pode ficar comprometida em função da distribuição da pressão de confinamento. No caso de pilares de seção circular, esta distribuição é uniforme. Já em pilares de seção quadrada e retangular, existe concentração de tensão nos cantos da seção transversal, o que, no caso de reforço por encamisamento com PRFC, pode causar a ruptura prematura da camisa, resultando num reforço ineficiente. Com o intuito de considerar as diferentes configurações da distribuição da pressão de confinamento, utiliza-se um coeficiente de forma, que em seções diferentes da circular (para a qual este coeficiente é igual à unidade), minora o valor da pressão de confinamento, o qual é utilizado na previsão da carga de ruptura do pilar reforçado. Este trabalho tem como objetivo central o estudo de vários tipos de seção transversal com o intuito de avaliar a sua influência na eficiência do reforço e da ductilidade do elemento estrutural. Para tal, foram realizadas simulações experimentais com pilares de seção transversal circular, quadrada e retangular com os cantos arredondados, elíptica e uma seção composta por semicírculos. Os resultados demonstram que uma forma de seção transversal adequada é essencial para um bom desempenho do pilar reforçado, sendo assim, as seções transversais que apresentaram os melhores resultados foram a circular, a elíptica e a composta por semicírculos / The effect of the concrete confinement in columns submitted to the axial compression brings many benefits to its structural behavior, amongst them the increase of the axial compressive strength due to the action of the lateral pressures and the improvement of the ductility. In function of these advantages, the confinement is one of the main techniques for strengthening of concrete columns. However, depending on the shape of the cross section, the efficiency of the reinforcement can be impaired by the non-uniformity of the confinement pressure distribution. In the case of circular cross section columns, this distribution is uniform. Otherwise, in square and rectangular cross section columns, there is a pressure concentration at the cross section corners. In case of CFRP jackets, the pressure concentration leads to a premature rupture of the jacket, resulting in an inefficient reinforcement. Intending to consider the different confinement pressure distributions, a shape coefficient is applied to cross sections with distinguished shape from the circular one (for which this coefficient is equal to the unit), to correct the confinement pressure value. The corrected pressure is applied in theoretical evaluations of the column’s load carrying capacity. The main objective of work is to analyze the structural behavior of strengthened concrete columns with different shape cross-sections, evaluating the influences in the efficiency of the jacketing and in the ductility of the structural element. Experimental simulations were made in columns with the following cross section shapes: circular, square and rectangular with rounded corners, elliptical and a section composed by semicircles. The results demonstrated that an adequate shape of the cross-section is essential for a good performance of the strengthened columns. The cross sections that presented the best results were the circular, the elliptical and the one composed by semicircles
26

Resistência e ductilidade das ligações laje-pilar em lajes-cogumelo de concreto de alta resistência armado com fibras de aço e armadura transversal de pinos / Resistance and ductiliy of slab-column connections on high strength concrete flat slabs with steel fibers and shear reinforcement

Azevedo, Aline Passos de 22 April 1999 (has links)
Neste trabalho analisa-se a resistência à punção e a ductilidade das ligações laje-pilar em doze modelos de lajes-cogumelo de concreto armado, nas quais se efetuam combinações de emprego de concreto de alta resistência, diferentes volumes de fibras de aço e uso de armadura transversal na forma de conectores de aço tipo pino. Todas as lajes são quadradas com 1160 mm de lado e 100 mm de espessura. A armadura de flexão foi composta de barras de aço de 10 mm espaçadas de tal forma a resistir a um momento fletor único em ambas direções. Os conectores, quando utilizados, foram dispostos radialmente e compostos de barras de aço de 6.6 mm soldadas a segmentos de ferro chato nas duas extremidades. Para avaliar a capacidade resistente dos modelos de ligação laje-pilar e observar o ganho de ductilidade que as fibras proporcionam, foram ensaiados segmentos-de-laje, os quais representam uma faixa destes modelos de ligação laje-pilar. Foi utilizado um sistema de ensaio dotado de atuador hidráulico servo-controlado, programado para ensaio com deformação controlada e aquisição contínua dos dados, o que permitiu a avaliação do comportamento pós-pico de resistência e a realização de medições de resistência residual. Várias hipóteses de cálculo foram utilizadas para avaliar a resistência última das ligações laje-pilar. Empregou-se um critério de classificação para caracterizar o tipo de ruptura em: punção ou flexão predominante ou uma combinação de punção-flexão. Constatou-se que o emprego de concreto de alta resistência, juntamente com armadura transversal, aumenta substancialmente a resistência da ligação laje-pilar, e quando combinado com fibras de aço, consegue-se um considerável aumento da ductilidade. / This work analyses the punching shear resistance and ductility of slab-column connections on twelve concrete flat slab models. The model characteristics resulted from combinations of the application of high or ordinary strength concrete, different steel fiber volume fractions and use or not of shear reinforcement. All the slabs are square with 1,160 mm of side and 100 mm of thickness. The main flexural reinforcement was composed of 10 mm steel bars spaced in such a way to resist to the same bending moment in both directions. When used, the shear reinforcement of steel studs were disposed in radial directions and consisted of 6.6 mm steel bars welded to flat steel segments in their ends. To evaluate the resistant capacity of slab-column connection models and to observe the ductility that the fibers provide, they were rehearsed segments-of-slab, which represents a strip of these slab-column connection models. A testing system with a servo-controlled hydraulic jack was used and it was programmed for a controlled deformation test and continuous data acquisition. This method allowed the evaluation of the post-peak strength behavior and the measurement of residual resistance forces. Several calculations hypotheses were used to evaluate the ultimate strength of the slab-column connections. A classification criterium was applied to characterize the failure type as: predominant punching or flexure or a combination of punching-flexure. It was verified that the application of high strength concrete, together with shear reinforcement, increases substantially the slab-column connection strength, and, when combined with steel fibers, a considerable ductility increase is achieved.
27

Análise crítica do ensaio de determinação da curva mestre (ASTM E 1921) aplicado a um aço da classe API 5L X80. / Critique analyse of essay of determination of master curve (ASTM E 1921) applied the an API 5L X80 steel.

Passagem, Fernando Cesar Loss 20 January 2011 (has links)
Um dos aspectos cruciais do projeto estrutural é a consideração dos efeitos de escala para os materiais que apresentam comportamento quase frágil (quase-brittle). Para tanto se desenvolveu na engenharia o método da curva mestre (upper shelf), aplicável a aços ferríticos operando em temperaturas contidas no intervalo característico da transição dúctil frágil. Este método combina ensaio de impacto e ensaios de tenacidade à fratura em corpos de prova padronizados, propondo-se a descrever o comportamento da tenacidade à fratura em todo o intervalo de temperatura da região de transição dúctil-frágil, para qualquer dimensão característica da estrutura. Este método tem como hipótese básica que a fratura se inicia por clivagem no microconstituinte mais frágil (geralmente a ferrita). Este trabalho se propõe a investigar esta hipótese, comparando análises das superfícies de fratura nas diferentes condições de carregamento dos diferentes ensaios mecânicos (tração, impacto e curva J-R) obtidos no âmbito de um ensaio de determinação da curva mestre em um aço da classe API 5L X80. Os resultados mostram que as superfícies de fratura indicam a ação de diversos micros mecanismos em função das diferentes taxas de carregamento, que levantam questão sobre os fundamentos do ensaio de determinação da curva mestre. / One of the key aspects of structural integrity is the consideration of scale effects characteristic of materials wich present quase-brittle behavior. The Master curve method, designed for ferritic steels operating at temperatures in the materials corresponding to the ductile-brittle transition. This method combine charpy impact testing and a few fracture toughness tests in standard specimens and is supposedly able to reproduce the materials fracture toughness in the whole ductile-to-brittle transition temperature interval for any characteristic size of the structure. This method relies on the basic hypothesis that fracture is initiated by cleavage the most brittle micro constituent (generally ferrite). This work investigates this hypothesis by comparing the fracture surfaces obtained under the loading conditions of the different mechanical tests used in the method (tensile, impact and J.R. curve) for the determination of the master curve of an API 5L X80 steel. The results show that these fracture surfaces indicate the action of different fracture micro mechanisms raising doubts on the applicability of the method.
28

Estudo das variáveis que afetam a tenacidade e a ductilidade do aço PH13-8Mo utilizado na indústria aeronáutica

Moreno, Rômulo Fernandes 27 October 2012 (has links)
Made available in DSpace on 2016-06-02T19:12:30Z (GMT). No. of bitstreams: 1 5457.pdf: 7456737 bytes, checksum: 1d18f487e08219cebbd323e719bd80ff (MD5) Previous issue date: 2012-10-27 / Precipitation Hardening Stainless Steel PH13-8Mo is a high strength steel used in the aerospace industry. Beyond the high strength, this grade has relatively high toughness and ductility for the strength achieved. The aerospace industry is increasingly asking for high strength materials with higher toughness and ductility than the actual limits required. Villares Metals, manufacturer of specialty steels and alloys, supplies the 13-8 steel (Villares grade N4534QA) for the aerospace industry like Embraer and ELEB (landing gear manufacturer of Embraer aircrafts). Although Villares 13-8 steel meets the international and the aerospace specifications, is characteristic of this company to improve its products and follow the new requirements of the customers and the market. Thus, is of its interest to produce the 13-8 steel with higher toughness and ductility. Therefore, the objective of this work is to study the variables which affect the 13-8 steel toughness and ductility aiming to produce it with improved properties. It were studied the effect of the alloying and residual elements, steelmaking process (remelting), hot forming process (forging and rolling) and heat treatment process. The verification of these effects was verified through tensile and impact Charpy V tests. / O aço inoxidável endurecível por precipitação PH13-8Mo (13-8) é um aço de elevada resistência mecânica utilizado na indústria aeronáutica. Além da elevada resistência mecânica, este aço possui ductilidade e tenacidade relativamente elevadas para o nível de resistência atingido. A indústria aeronáutica vem, cada vez mais, solicitando materiais de alta resistência mecânica com tenacidade e ductilidade mais elevadas em relação às solicitações atuais. A Villares Metals, usina siderúrgica produtora de aços e ligas especiais, é fornecedora do aço 13-8 (marca Villares N4534QA) para as indústrias do segmento aeronáutico, como Embraer e ELEB (fabricante dos trens de pouso dos aviões da Embraer). Apesar do aço 13-8 da Villares Metals atender as principais normas internacionais e do segmento aeronáutico, é prática desta empresa estar sempre buscando melhorar os seus produtos e acompanhar as novas solicitações dos clientes e do mercado. Sendo assim, é de seu interesse produzir o aço 13-8 com tenacidade e ductilidade mais elevadas. Portanto, o objetivo deste trabalho é estudar as variáveis que afetam a tenacidade e a ductilidade do aço 13-8 com o objetivo de se obtê-lo com estas propriedades otimizadas. Foram estudados os efeitos de elementos de liga, de elementos residuais, do processo de elaboração (refusão), dos processos de conformação a quente (forjamento e laminação) e do processo de tratamento térmico. A verificação desses efeitos foi realizada através de ensaios mecânicos de tração e de impacto Charpy V.
29

Estudo teórico-experimental de pilares mistos compostos por tubos de aço preenchidos com concreto de alta resistência. / Theoretical and experimental study of high strength concrete filled steel tubes

Silvana De Nardin 25 March 1999 (has links)
O emprego de pilares mistos formados por tubos de aço preenchidos com concreto de alta resistência, sobretudo em edifícios altos, é uma tendência em diversos países europeus, americanos e asiáticos. A tais elementos são atribuídas vantagens como: alta resistência e ductilidade, economia de materiais e mão-de-obra, redução das dimensões da seção transversal e melhoria no comportamento dos materiais aço e concreto, devido ao efeito de confinamento. Buscando suprir algumas carências de conhecimento, procura-se obter dados experimentais sobre o comportamento de pilares mistos axialmente comprimidos, possibilitando desta forma avaliar parâmetros como influência da forma da seção transversal e da espessura do perfil tubular no seu comportamento. Foram analisadas seções quadradas, circulares e retangulares, preenchidas por concreto com resistência média de 50MPa. A ruína destes elementos caracterizou-se pelo esmagamento do concreto, ocorrendo posteriormente a flambagem local do perfil em diversos pontos. A capacidade resistente prevista por diversas normas resultou em valores muito próximos dos experimentais, embora várias destas normas não considerem o efeito de confinamento. Os ensaios mostraram que o efeito de confinamento contribui de forma decisiva na melhoria do comportamento dos materiais, sobretudo ductilizando o concreto de alta resistência, entretanto seus efeitos não são significativos no aumento da capacidade resistente da seção mista. Alguns critérios para avaliação da ductilidade à compressão foram adaptados e mostraram bons resultados, possibilitando o cálculo do índice de ductilidade. / The use of concrete filled steel tubes especially in tall buildings is a tendency in several european, american and asian countries. The use of these members has several advantages: high resistance and ductility, saving of materials and labour, reduction of cross section dimensions and improvement in behaviour of the materials steel and concrete due the confinement. The main purpose of this study is provide some experimental results of the behaviour of concrete filled steel tubes concentrically loaded. The main experimental parameters considered were the influence of the cross-section shape and thickness of steel tube. Square, circular and rectangular cross-section shapes infilling with concrete of the 50MPa of strength were analyzed. The failure was characterized for crushing of the concrete and later local buckling of the steel section in several points. The strength capacity predicted for several standards showed good agreement with the experimental failure values although this does not consider the confinement of the concrete. The results of tests showed that the confinement effect contributes for improvement behaviour of materials, especially increasing the ductility of the high strength concrete. However the results showed that the triaxial confinement does not increase the axial capacity of the concrete filled steel tubes. Some methods to estimate the ductility of axially compressed concrete columns were adapted and showed good results permitting the calculation of the ductility index of short columns.
30

Influência da forma de seção transversal no confinamento de pilares de concreto armado encamisados com PRFC (polímero reforçado com fibras) / Influence of the cross section shape in the confinement of jacketed reinforced concrete columns with CFRP (carbon fiber reinforced polymer)

Alexandre Luis Sudano 31 May 2005 (has links)
O efeito de confinamento do concreto em pilares submetidos à compressão axial traz diversos benefícios ao seu comportamento estrutural, dentre os quais destacam-se o aumento na resistência à compressão axial do concreto pela ação das pressões laterais, e a melhoria da ductilidade do elemento estrutural. Em função destas vantagens, o confinamento é uma das principais técnicas de reforço de pilares de concreto. Porém, dependendo da forma da seção transversal, a eficiência do reforço pode ficar comprometida em função da distribuição da pressão de confinamento. No caso de pilares de seção circular, esta distribuição é uniforme. Já em pilares de seção quadrada e retangular, existe concentração de tensão nos cantos da seção transversal, o que, no caso de reforço por encamisamento com PRFC, pode causar a ruptura prematura da camisa, resultando num reforço ineficiente. Com o intuito de considerar as diferentes configurações da distribuição da pressão de confinamento, utiliza-se um coeficiente de forma, que em seções diferentes da circular (para a qual este coeficiente é igual à unidade), minora o valor da pressão de confinamento, o qual é utilizado na previsão da carga de ruptura do pilar reforçado. Este trabalho tem como objetivo central o estudo de vários tipos de seção transversal com o intuito de avaliar a sua influência na eficiência do reforço e da ductilidade do elemento estrutural. Para tal, foram realizadas simulações experimentais com pilares de seção transversal circular, quadrada e retangular com os cantos arredondados, elíptica e uma seção composta por semicírculos. Os resultados demonstram que uma forma de seção transversal adequada é essencial para um bom desempenho do pilar reforçado, sendo assim, as seções transversais que apresentaram os melhores resultados foram a circular, a elíptica e a composta por semicírculos / The effect of the concrete confinement in columns submitted to the axial compression brings many benefits to its structural behavior, amongst them the increase of the axial compressive strength due to the action of the lateral pressures and the improvement of the ductility. In function of these advantages, the confinement is one of the main techniques for strengthening of concrete columns. However, depending on the shape of the cross section, the efficiency of the reinforcement can be impaired by the non-uniformity of the confinement pressure distribution. In the case of circular cross section columns, this distribution is uniform. Otherwise, in square and rectangular cross section columns, there is a pressure concentration at the cross section corners. In case of CFRP jackets, the pressure concentration leads to a premature rupture of the jacket, resulting in an inefficient reinforcement. Intending to consider the different confinement pressure distributions, a shape coefficient is applied to cross sections with distinguished shape from the circular one (for which this coefficient is equal to the unit), to correct the confinement pressure value. The corrected pressure is applied in theoretical evaluations of the column’s load carrying capacity. The main objective of work is to analyze the structural behavior of strengthened concrete columns with different shape cross-sections, evaluating the influences in the efficiency of the jacketing and in the ductility of the structural element. Experimental simulations were made in columns with the following cross section shapes: circular, square and rectangular with rounded corners, elliptical and a section composed by semicircles. The results demonstrated that an adequate shape of the cross-section is essential for a good performance of the strengthened columns. The cross sections that presented the best results were the circular, the elliptical and the one composed by semicircles

Page generated in 0.0601 seconds