• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 46
  • Tagged with
  • 46
  • 15
  • 13
  • 13
  • 12
  • 11
  • 11
  • 10
  • 10
  • 9
  • 9
  • 8
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

[en] DYNAMIC BEHAVIOR OF BURIED PIPES: METHODOLOGY AND COMPUTATIONAL IMPLEMENTATION / [pt] COMPORTAMENTO DINÂMICO DE DUTOS ENTERRADOS: METODOLOGIA E IMPLEMENTAÇÃO COMPUTACIONAL

IGOR EDUARDO OTINIANO MEJIA 31 March 2009 (has links)
[pt] Neste trabalho apresenta-se uma metodologia de análise do comportamento mecânico de dutos enterrados usados no transporte de gás e outros fluidos sujeitos a cargas dinâmicas. Em especial são considerados carregamentos provocados por sismos. Emprega-se uma modelagem em elementos finitos com base em uma discretização com elementos especiais de viga para modelar o duto. Não linearidades geométricas e do material são consideradas numa formulação Lagrangeana total. As equações de equilíbrio são formuladas a partir do principio dos trabalhos virtuais, segundo as componentes de tensão e deformação no elemento viga-duto. A técnica do Módulo Reduzido de Integração Direta (RMDI) é empregada na qual se incorpora o comportamento elasto-plástico do material. Esta abordagem exclui da análise os efeitos do enrugamento nas paredes do duto. As matrizes para resolução por elementos finitos dessas equações são derivadas. Nessa metodologia os efeitos da interação solo-duto são incorporados. O solo é modelado através de elementos bidimensionais considerando um modelo constitutivo Linear- Equivalente, acoplados ao duto por meio de elementos de interface localizados entre o duto e o solo. Finalmente são considerados contornos artificiais amortecidos para possibilitar a representação do problema através de um trecho finito. Foram usados para as análises históricos de acelerações do tipo sismo, entre estes o sismo ocorrido em Pisco-Perú no ano 2007. Desenvolve-se um programa para computador segundo a metodologia apresentada. Finalmente são estudados alguns exemplos com o objetivo de avaliar numericamente os resultados da análise obtidos e formular algumas conclusões sobre o comportamento de dutos enterrados sujeitos a cargas dinâmicas. / [en] This work presents a numerical methodology for the analysis of buried pipes employed by the transport of oil and gas subject to dynamic loads. Emphasis is given to seismic loads. A finite element model based on a special class of beam element for the pipe representation is employed. Both geometric and material nonlinearities are considered in a total Lagrangean formulation. The equilibrium equations are formulated based on the virtual work principle considering the stress and deformation components of the beam-pipe element. The Reduced Modulus Direct Integration (RMDI) technique is employed by which the elasto-plastic material behavior is incorporated. This technique excludes from the analysis the local buckling effects of the pipe walls. The corresponding finite element matrices for this element are obtained. In this methodology the effects of the constant internal pressure as well as the soil-pipe interaction are included. The soil is modeled through two-dimensional elements with material behavior described through a linear equivalent model. Interface elements couple beam-pipe elements with soil elements and account for soil-pipe interaction. Finally silent boundary elements are incorporated to the model to reproduce the semi-infinite boundary conditions in the finite size model. Distributed loads are considered constant with respect to the global axis. Acceleration histories are applied to simulate seismic dynamic loads among which the acceleration histories of the earthquake which occurred in Pisco-Perú in 2007. A finite element computer code is developed according to the methodology presented. Some examples are studied with the objective to evaluate numerically the analysis results and to formulate some conclusions to the behavior of buried pipes subject to seismic loads.
22

Modelagem física de condutos enterrados sujeitos a perda de apoio ou elevação localizada / Physical modeling of buried pipes subjected to localized loss of support or elevation

Costa, Yuri Daniel Jatobá 24 May 2005 (has links)
Este trabalho apresenta um estudo experimental sobre o comportamento de dutos enterrados sofrendo perda de apoio ou elevação em uma determinada região ao longo do comprimento. Foram realizados ensaios com modelos físicos compostos por um maciço de areia pura contendo um tubo repousando sobre um alçapão localizado no centro do vão. A pesquisa envolveu dois programas experimentais distintos. O primeiro foi desenvolvido na Escola de Engenharia de São Carlos/USP e contou com o desenvolvimento e a construção de um equipamento de ensaios possuindo um sistema de alçapão. Os modelos eram dotados de instrumental capaz de medir as deflexões e as deformações específicas ao longo do duto, além das tensões totais no maciço de solo circundante e na base do equipamento. O segundo programa experimental foi conduzido na Universidade do Colorado em Boulder, EUA, e envolveu ensaios em centrífuga. Essa fase da pesquisa teve por finalidade realizar uma investigação visual dos mecanismos de ruptura do sistema composto pelo solo e pelo duto sujeito à perda de apoio. Ambas as etapas do trabalho contaram com a execução de testes com modelos sem tubo. Os ensaios realizados revelaram aspectos importantes do problema investigado. A movimentação ativa ou passiva do alçapão exerceu uma forte influência na redistribuição das tensões no maciço de solo exterior à estrutura, a qual abrangeu distâncias horizontais superiores a 5 B e verticais superiores a 4 B. Após a perda de apoio ou a elevação, o topo, a base e as demais partes do conduto assumiram perfis de deflexão distintos ao longo do comprimento, os quais foram consideravelmente influenciados pela densidade relativa do solo e pela sobrecarga aplicada. A movimentação ativa do alçapão revelou ainda padrões de ruptura incluindo localizações de deformação propagando-se para a região do maciço de solo fora do alçapão / This thesis presents an experimental study on the behavior of buried pipes undergoing a loss of support or elevation in a localized region along its length. Tests with physical models comprising a pure dry sand and a tube resting on a rigid trapdoor base located at the center of its length were performed. The research included two distinct testing programs. The first testing program was carried out at the School of Engineering of Sao Carlos/USP, and included the construction of a laboratory facility containing a trapdoor system. The models were equipped with devices for measuring deflections and strains in the pipe, and total stresses in the soil mass and in the lower boundary of the model. The second phase of this investigation was conducted at the University of Colorado at Boulder, USA, and involved centrifuge testing. The main goal of this part of the research was to assess the failure mechanisms that take place when the pipe experiences loss of support. Models without the pipe were also tested in both phases. Important aspects of the soil-structure interaction were verified with the testing programs carried out in this study. A strong influence on the stress redistribution within the soil mass in the vicinity of the structure was achieved after the active or passive conditions were established, encompassing horizontal distances greater than 5 B and vertical distances greater than 4 B. The crown, the base, and the other parts of the pipe assumed distinct deflection profiles after the loss of support or elevation, which were strongly influenced by the relative density of the surrounding soil and by the surficial applied surcharge. The imposed downward boundary movement included the formation of shear bands initiating at the edge of the void and propagating towards the soil mass in the vicinity of the trapdoor
23

Estudo experimental de escoamento multifásico em duto anular de grande diâmetro / Experimental study of multiphase flow in large annular duct

Colmanetti, Alex Roger Almeida 29 September 2016 (has links)
Escoamentos gás-líquido assim como escoamento líquido-líquido-gás em duto de geometria anular estão presentes em muitas aplicações industriais, por exemplo, em poços de petróleo direcionais. No entanto, até mesmo características globais de escoamento gás-líquido nessa geometria, como os padrões de escoamento ou gradiente de pressão, não são ainda totalmente compreendidas. E ainda, informações são escassas quando se refere a escoamento trifásico nessa geometria, cuja aplicação está relacionada ao fenômeno de inversão de fase, que é de extrema importância não apenas para ao setor petrolífero, como para a indústria alimentícia. O presente estudo experimental tem como objetivo avaliar o escoamento líquido-gás, apresentar dados inéditos de escoamento gás-líquido para três viscosidades de óleo, além de avaliar o fenômeno de inversão de fase em escoamento ascendente vertical em duto anular de grande diâmetro. Um aparato experimental inclinável com 10,5 m de comprimento foi projetado e construído para este trabalho. As dimensões radiais do duto anular estão em escala real, conforme se verifica em poços de petróleo e gás. A investigação em escoamento gás-líquido foi conduzida utilizando água, óleo e ar comprimido como fluidos de trabalho em escoamento ascendente vertical em duas geometrias: (i) um tubo com diâmetro de 95 mm e (ii) um duto de configuração anular e concêntrico, com diâmetro hidráulico de valor igual ao diâmetro do tubo. A avaliação do fenômeno de inversão de fase em escoamento trifásico foi conduzida em condições equivalentes em três geometrias: (i) tubo vertical menor com diâmetro de 50 mm, (ii) tubo com diâmetro de 95 mm e (iii) um duto anular concêntrico. Padrões de escoamento, queda de pressão e fração volumétrica de fase foram obtidos para ambos os escoamentos gás-líquido e líquido-líquido-gás. Os dados coletados nesse trabalho são de grande importância para o desenvolvimento de novas correlações de fechamento, que são essenciais para o projeto otimizado de poços de petróleo. Dados inéditos de escoamento bifásico óleo-gás são apresentados, bem como um estudo pioneiro em inversão de fase em escoamento trifásico com velocidade superficial de gás e viscosidade do óleo elevadas. / Two-phase flows as well as three-phase flow in annular geometry are present in many industrial applications, for example in oil directional wells. However, even global characteristics of gas-liquid flow in this geometry, such as flow patterns and pressure gradient are not fully understood. Moreover, information is scarce when it refers to three-phase flow in this geometry, which application is related to the phase inversion phenomenon, which is of extreme importance and not only for the oil industry. This experimental study aims to evaluate the liquid-gas flow, present new data from gas-liquid flow for three oil viscosities and evaluate the phase inversion phenomenon in vertical upward flow in large diameter annular duct. An experimental apparatus with 10.5 m length was designed and built for this work. The radial dimensions of the annular duct are similar to full scale, as observed in oil and gas wells. The investigation into gas-liquid flow was conducted using water, oil and compressed air as working fluids in an ascending vertical flow in two geometries: (i) a tube with 95 mm diameter and (ii) a concentric annular duct with hydraulic diameter equivalent to the tube internal diameter. The evaluation of the phase inversion phenomenon in three-phase flow was conducted under equivalent conditions for three geometries: (i) smaller vertical tube with 50 mm of internal diameter, (ii) tube with 95 mm of internal diameter and (iii) concentric annular duct with hydraulic diameter of 95 mm. Flow patterns, pressure drop and volumetric phase fraction were obtained for both gas-liquid and gas-liquid-liquid flows. The data collected in this study are of great importance for the development of new closing correlations, which are essential for the optimized design of oil wells. New two-phase flow data for three oil viscosities, not found in the literature, are presented as well as a pioneer study in three-phase-flow phase inversion with high oil viscosity and high superficial gas velocity.
24

Aspectos metalúrgicos de revestimentos em dutos depositados com a superliga de níquel ERNiCrMo-4 pelos processos MIG convencional e MIG com adição de arame frio

SANTOS, Marcio Wagner Batista dos 02 August 2012 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-04-07T16:26:32Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AspectosMetalurgicosRevestimentos.pdf: 5320680 bytes, checksum: 75f9c2d40f9a30c809779506ac9808b0 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-06-17T14:59:39Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AspectosMetalurgicosRevestimentos.pdf: 5320680 bytes, checksum: 75f9c2d40f9a30c809779506ac9808b0 (MD5) / Made available in DSpace on 2014-06-17T14:59:39Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AspectosMetalurgicosRevestimentos.pdf: 5320680 bytes, checksum: 75f9c2d40f9a30c809779506ac9808b0 (MD5) Previous issue date: 2012 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho estuda o perfil metalúrgico de revestimentos em dutos depositados pelos processos MIG C e MIG AF. A indústria petroquímica, e outras que utilizam dutos como meio de transporte de seus insumos, depara-se com um grande desafio: como aumentar a vida útil desses dutos em um ambiente severo de trabalho. No caso específico da petroquímica, os dutos servem como meio de transporte para petróleo e gás, que são produtos extremamente agressivos às paredes internas desses tubos que sofrem degradação por corrosão causada, principalmente, pela composição química, pressão e temperatura desses produtos. Nesse contexto a soldagem de revestimentos realizada com ligas à base de Níquel, torna-se uma excelente opção para a construção, reparo e manutenção de equipamentos cuja aplicação seja voltada a ambientes severos de trabalho, tornando possível aperfeiçoar as características requeridas, como por exemplo, a resistência à corrosão. É nesse cenário que surge o mote para a realização desta pesquisa, baseada em trabalhos que indicam que o processo de soldagem MIG/MAG com o da adição de arame frio possui a finalidade de avaliar as características metalúrgicas do revestimento em dutos depositados pelo processo derivativo MIG convencional – MIG-C e MIG com adição de arame frio – MIG AF – utilizando a liga de Níquel ERNiCrMo-4 em dutos de aço carbono. As soldas foram depositadas em dutos de diâmetro de 228,6 mm, formando uma camada de revestimento interno de quatro passes, divididos em três segmentos da circunferência do duto, em três diferentes energias de soldagem: 1,1; 0,9 e 0,7 kJ/mm. Desses segmentos retiraram-se corpos de prova dos dutos para a produção das amostras. Após a metalografia, realizada nas amostras, seguiu-se com a análise e caracterização ao microscópio óptico, microscópio eletrônico de varredura e ensaio de microdureza. Os revestimentos apresentaram excelente qualidade superficial para todos os pacotes operacionais aplicados na obtenção das soldas. As análises das regiões estudadas: metal de base; zona parcialmente misturada e zona termicamente afetada, mostraram-se compatíveis com os da literatura estudada, tanto para o MIG com adição de arame frio, quanto para o convencional. Na ZTA, foram observados valores de Tungstênio em torno de 1,0%, o aumento dos níveis de dureza foi creditado a esse fato. Os resultados de microdureza indicaram que para ambos os casos, MIG C e MIG AF, nas 4 regiões analisadas ocorreram de maneira semelhante, sendo a região da ZTA a que apresentou maiores valores na faixa de 400 a 500 HV, enquanto que nas demais regiões a faixa ficou entre 250 a 350 HV. Os resultados indicam que o processo com arame frio, MIG AF, mostrou-se tão eficiente quanto o convencional, MIG C. A energia de soldagem aumentou a diluição de Fe no metal de solda. Precipitados ricos em Mo e Cr foram encontrados no metal de solda. / This work is a metallurgical analysis of the inner lining layer of pipeline used in welding process MIG C and MIG AF. The petrochemical industry, and others that use pipelines for transportation of their raw materials, faces a major challenge: how to increase the useful life of these products in a harsh environment work? In the specific case of the petrochemical industry, whom this research is directed, the pipes serve as means of transportation for oil and gas, products that are extremely aggressive to the internal walls of these tubes that are degraded by corrosion, caused mainly, by chemical composition, pressure and temperature these products. In this context the welding of lining made with nickel-based alloys becomes an excellent option for the construction, repair and maintenance of equipment whose application be returned in harsh environments of work, allowing the improvement of characteristics required, such as the resistance to corrosion. It is this scenario that emerges the theme for this research, based on studies that indicate that the process of welding MIG / MAG with the addition of cold wire, has to evaluate the metallurgical characteristics of the pipeline coating deposited by the derivative process MIG conventional – MIG-C and MIG with the addition of cold wire - MIG AF - using Nickel alloy ERNiCrMo-4 in carbon steel pipelines. The welds were deposited in pipes of 228.6 mm of diameter, forming a layer of internal lining of four passes, divided into three segments of the circumference of the duct, in three different welding energy: 1.1, 0.9 and 0.7 kJ / mm. These segments are removed specimens of the ducts, for the production of the samples. After metallography, performed on the samples, followed with the analysis and characterization by optical microscope, scanning electron microscope and testing of microhardness. The coatings exhibited excellent surface quality for all operational packages used in obtaining the welds. The results of the analysis of the regions studied: metal base, partially mixed zone and heat affected zone, were compatible with the literature studied for both the MIG with the addition of cold wire, as for the conventional. In HAZ were observed values of Tungsten around 1.0%, the increased levels of hardness was credited to this fact. The microhardness results indicated that in both cases, MIG C and MIG AF, in 4 regions analyzed occurred similarly, and the HAZ region which showed the highest values in the range 400-500 HV, while in the other regions range was between 250-350 HV. The results indicate that the process with cold wire, MIG AF, was as efficient as the conventional MIG C. The welding power increased the dilution of Fe in the weld metal. Precipitates rich in Mo and Cr were found in the weld metal.
25

A hipótese da reparação civil por abandono afetivo do idoso que decorre da infração ao dever de cuidado

Faraco, Luciane Lovato January 2018 (has links)
Este trabalho versa sobre a hipótese de reparação civil por abandono afetivo que decorre da infração ao dever de cuidado do idoso. Analisa-se a tutela dos direitos dos idosos no ordenamento jurídico brasileiro através de um retrospecto legal com sutil referência ao contexto histórico mundial e ao Direito Comparado. Contextualiza-se a interpretação dos direitos dos idosos em face do fundamento do Direito pátrio na dignidade da pessoa humana a partir da Constituição Federal de 1988 e a transposição desta no Direito Civil e no Direito de Família. Adiante é apreciado o abandono afetivo, seu conceito e expansão pela a adoção do modelo atual eudemonista da família que importou na inclusão do dever de cuidado como elemento do afeto. A seguir o cuidado é abordado enquanto infração ao dever que dele decorre para identificação da conduta omissiva. Por fim, é explorado o instituto da responsabilidade civil, através do estudo de cada um dos seus requisitos, para conclusão quanto ao cabimento do dever de reparação pela constatação da ocorrência do ato ilícito de infração ao dever de cuidado que implica abandono afetivo em razão do dano que dele resulta e da extensão deste, isto valorado no caso concreto. / This paper deals with the hypothesis of civil reparation for affective abandonment of the elderly that results from the violation of the duty of care of the elderly. It analyzes the protection of the rights of the elderly in the Brazilian legal system through a legal retrospect with subtle reference to the world historical context and Comparative Law. The interpretation of the rights of the elderly in the face of the foundation of the patrimony right in the dignity of the human being is contextualized from the Federal Constitution of 1988 and the transposition of this one in the Civil Law and in the Right of Family. Above, affection abandonment, its concept and its expansion are appreciated by the adoption of the current eudemonist model of the family that has imported the inclusion of the duty of care as an element of affection. Care is then approached as an infraction of the duty derived from it to identify the omissive conduct. Finally, the institute of civil responsibility is explored, through the study of each one of its requirements, to conclude on the compliance of the duty to make reparation for the finding of the occurrence of the illicit act of infraction to the duty of care that implies affective abandonment due to the damage that results from it and the extent of it, that is valued in the concrete case.
26

A hipótese da reparação civil por abandono afetivo do idoso que decorre da infração ao dever de cuidado

Faraco, Luciane Lovato January 2018 (has links)
Este trabalho versa sobre a hipótese de reparação civil por abandono afetivo que decorre da infração ao dever de cuidado do idoso. Analisa-se a tutela dos direitos dos idosos no ordenamento jurídico brasileiro através de um retrospecto legal com sutil referência ao contexto histórico mundial e ao Direito Comparado. Contextualiza-se a interpretação dos direitos dos idosos em face do fundamento do Direito pátrio na dignidade da pessoa humana a partir da Constituição Federal de 1988 e a transposição desta no Direito Civil e no Direito de Família. Adiante é apreciado o abandono afetivo, seu conceito e expansão pela a adoção do modelo atual eudemonista da família que importou na inclusão do dever de cuidado como elemento do afeto. A seguir o cuidado é abordado enquanto infração ao dever que dele decorre para identificação da conduta omissiva. Por fim, é explorado o instituto da responsabilidade civil, através do estudo de cada um dos seus requisitos, para conclusão quanto ao cabimento do dever de reparação pela constatação da ocorrência do ato ilícito de infração ao dever de cuidado que implica abandono afetivo em razão do dano que dele resulta e da extensão deste, isto valorado no caso concreto. / This paper deals with the hypothesis of civil reparation for affective abandonment of the elderly that results from the violation of the duty of care of the elderly. It analyzes the protection of the rights of the elderly in the Brazilian legal system through a legal retrospect with subtle reference to the world historical context and Comparative Law. The interpretation of the rights of the elderly in the face of the foundation of the patrimony right in the dignity of the human being is contextualized from the Federal Constitution of 1988 and the transposition of this one in the Civil Law and in the Right of Family. Above, affection abandonment, its concept and its expansion are appreciated by the adoption of the current eudemonist model of the family that has imported the inclusion of the duty of care as an element of affection. Care is then approached as an infraction of the duty derived from it to identify the omissive conduct. Finally, the institute of civil responsibility is explored, through the study of each one of its requirements, to conclude on the compliance of the duty to make reparation for the finding of the occurrence of the illicit act of infraction to the duty of care that implies affective abandonment due to the damage that results from it and the extent of it, that is valued in the concrete case.
27

Estudo experimental de escoamento multifásico em duto anular de grande diâmetro / Experimental study of multiphase flow in large annular duct

Alex Roger Almeida Colmanetti 29 September 2016 (has links)
Escoamentos gás-líquido assim como escoamento líquido-líquido-gás em duto de geometria anular estão presentes em muitas aplicações industriais, por exemplo, em poços de petróleo direcionais. No entanto, até mesmo características globais de escoamento gás-líquido nessa geometria, como os padrões de escoamento ou gradiente de pressão, não são ainda totalmente compreendidas. E ainda, informações são escassas quando se refere a escoamento trifásico nessa geometria, cuja aplicação está relacionada ao fenômeno de inversão de fase, que é de extrema importância não apenas para ao setor petrolífero, como para a indústria alimentícia. O presente estudo experimental tem como objetivo avaliar o escoamento líquido-gás, apresentar dados inéditos de escoamento gás-líquido para três viscosidades de óleo, além de avaliar o fenômeno de inversão de fase em escoamento ascendente vertical em duto anular de grande diâmetro. Um aparato experimental inclinável com 10,5 m de comprimento foi projetado e construído para este trabalho. As dimensões radiais do duto anular estão em escala real, conforme se verifica em poços de petróleo e gás. A investigação em escoamento gás-líquido foi conduzida utilizando água, óleo e ar comprimido como fluidos de trabalho em escoamento ascendente vertical em duas geometrias: (i) um tubo com diâmetro de 95 mm e (ii) um duto de configuração anular e concêntrico, com diâmetro hidráulico de valor igual ao diâmetro do tubo. A avaliação do fenômeno de inversão de fase em escoamento trifásico foi conduzida em condições equivalentes em três geometrias: (i) tubo vertical menor com diâmetro de 50 mm, (ii) tubo com diâmetro de 95 mm e (iii) um duto anular concêntrico. Padrões de escoamento, queda de pressão e fração volumétrica de fase foram obtidos para ambos os escoamentos gás-líquido e líquido-líquido-gás. Os dados coletados nesse trabalho são de grande importância para o desenvolvimento de novas correlações de fechamento, que são essenciais para o projeto otimizado de poços de petróleo. Dados inéditos de escoamento bifásico óleo-gás são apresentados, bem como um estudo pioneiro em inversão de fase em escoamento trifásico com velocidade superficial de gás e viscosidade do óleo elevadas. / Two-phase flows as well as three-phase flow in annular geometry are present in many industrial applications, for example in oil directional wells. However, even global characteristics of gas-liquid flow in this geometry, such as flow patterns and pressure gradient are not fully understood. Moreover, information is scarce when it refers to three-phase flow in this geometry, which application is related to the phase inversion phenomenon, which is of extreme importance and not only for the oil industry. This experimental study aims to evaluate the liquid-gas flow, present new data from gas-liquid flow for three oil viscosities and evaluate the phase inversion phenomenon in vertical upward flow in large diameter annular duct. An experimental apparatus with 10.5 m length was designed and built for this work. The radial dimensions of the annular duct are similar to full scale, as observed in oil and gas wells. The investigation into gas-liquid flow was conducted using water, oil and compressed air as working fluids in an ascending vertical flow in two geometries: (i) a tube with 95 mm diameter and (ii) a concentric annular duct with hydraulic diameter equivalent to the tube internal diameter. The evaluation of the phase inversion phenomenon in three-phase flow was conducted under equivalent conditions for three geometries: (i) smaller vertical tube with 50 mm of internal diameter, (ii) tube with 95 mm of internal diameter and (iii) concentric annular duct with hydraulic diameter of 95 mm. Flow patterns, pressure drop and volumetric phase fraction were obtained for both gas-liquid and gas-liquid-liquid flows. The data collected in this study are of great importance for the development of new closing correlations, which are essential for the optimized design of oil wells. New two-phase flow data for three oil viscosities, not found in the literature, are presented as well as a pioneer study in three-phase-flow phase inversion with high oil viscosity and high superficial gas velocity.
28

Modelagem física de condutos enterrados sujeitos a perda de apoio ou elevação localizada / Physical modeling of buried pipes subjected to localized loss of support or elevation

Yuri Daniel Jatobá Costa 24 May 2005 (has links)
Este trabalho apresenta um estudo experimental sobre o comportamento de dutos enterrados sofrendo perda de apoio ou elevação em uma determinada região ao longo do comprimento. Foram realizados ensaios com modelos físicos compostos por um maciço de areia pura contendo um tubo repousando sobre um alçapão localizado no centro do vão. A pesquisa envolveu dois programas experimentais distintos. O primeiro foi desenvolvido na Escola de Engenharia de São Carlos/USP e contou com o desenvolvimento e a construção de um equipamento de ensaios possuindo um sistema de alçapão. Os modelos eram dotados de instrumental capaz de medir as deflexões e as deformações específicas ao longo do duto, além das tensões totais no maciço de solo circundante e na base do equipamento. O segundo programa experimental foi conduzido na Universidade do Colorado em Boulder, EUA, e envolveu ensaios em centrífuga. Essa fase da pesquisa teve por finalidade realizar uma investigação visual dos mecanismos de ruptura do sistema composto pelo solo e pelo duto sujeito à perda de apoio. Ambas as etapas do trabalho contaram com a execução de testes com modelos sem tubo. Os ensaios realizados revelaram aspectos importantes do problema investigado. A movimentação ativa ou passiva do alçapão exerceu uma forte influência na redistribuição das tensões no maciço de solo exterior à estrutura, a qual abrangeu distâncias horizontais superiores a 5 B e verticais superiores a 4 B. Após a perda de apoio ou a elevação, o topo, a base e as demais partes do conduto assumiram perfis de deflexão distintos ao longo do comprimento, os quais foram consideravelmente influenciados pela densidade relativa do solo e pela sobrecarga aplicada. A movimentação ativa do alçapão revelou ainda padrões de ruptura incluindo localizações de deformação propagando-se para a região do maciço de solo fora do alçapão / This thesis presents an experimental study on the behavior of buried pipes undergoing a loss of support or elevation in a localized region along its length. Tests with physical models comprising a pure dry sand and a tube resting on a rigid trapdoor base located at the center of its length were performed. The research included two distinct testing programs. The first testing program was carried out at the School of Engineering of Sao Carlos/USP, and included the construction of a laboratory facility containing a trapdoor system. The models were equipped with devices for measuring deflections and strains in the pipe, and total stresses in the soil mass and in the lower boundary of the model. The second phase of this investigation was conducted at the University of Colorado at Boulder, USA, and involved centrifuge testing. The main goal of this part of the research was to assess the failure mechanisms that take place when the pipe experiences loss of support. Models without the pipe were also tested in both phases. Important aspects of the soil-structure interaction were verified with the testing programs carried out in this study. A strong influence on the stress redistribution within the soil mass in the vicinity of the structure was achieved after the active or passive conditions were established, encompassing horizontal distances greater than 5 B and vertical distances greater than 4 B. The crown, the base, and the other parts of the pipe assumed distinct deflection profiles after the loss of support or elevation, which were strongly influenced by the relative density of the surrounding soil and by the surficial applied surcharge. The imposed downward boundary movement included the formation of shear bands initiating at the edge of the void and propagating towards the soil mass in the vicinity of the trapdoor
29

A hipótese da reparação civil por abandono afetivo do idoso que decorre da infração ao dever de cuidado

Faraco, Luciane Lovato January 2018 (has links)
Este trabalho versa sobre a hipótese de reparação civil por abandono afetivo que decorre da infração ao dever de cuidado do idoso. Analisa-se a tutela dos direitos dos idosos no ordenamento jurídico brasileiro através de um retrospecto legal com sutil referência ao contexto histórico mundial e ao Direito Comparado. Contextualiza-se a interpretação dos direitos dos idosos em face do fundamento do Direito pátrio na dignidade da pessoa humana a partir da Constituição Federal de 1988 e a transposição desta no Direito Civil e no Direito de Família. Adiante é apreciado o abandono afetivo, seu conceito e expansão pela a adoção do modelo atual eudemonista da família que importou na inclusão do dever de cuidado como elemento do afeto. A seguir o cuidado é abordado enquanto infração ao dever que dele decorre para identificação da conduta omissiva. Por fim, é explorado o instituto da responsabilidade civil, através do estudo de cada um dos seus requisitos, para conclusão quanto ao cabimento do dever de reparação pela constatação da ocorrência do ato ilícito de infração ao dever de cuidado que implica abandono afetivo em razão do dano que dele resulta e da extensão deste, isto valorado no caso concreto. / This paper deals with the hypothesis of civil reparation for affective abandonment of the elderly that results from the violation of the duty of care of the elderly. It analyzes the protection of the rights of the elderly in the Brazilian legal system through a legal retrospect with subtle reference to the world historical context and Comparative Law. The interpretation of the rights of the elderly in the face of the foundation of the patrimony right in the dignity of the human being is contextualized from the Federal Constitution of 1988 and the transposition of this one in the Civil Law and in the Right of Family. Above, affection abandonment, its concept and its expansion are appreciated by the adoption of the current eudemonist model of the family that has imported the inclusion of the duty of care as an element of affection. Care is then approached as an infraction of the duty derived from it to identify the omissive conduct. Finally, the institute of civil responsibility is explored, through the study of each one of its requirements, to conclude on the compliance of the duty to make reparation for the finding of the occurrence of the illicit act of infraction to the duty of care that implies affective abandonment due to the damage that results from it and the extent of it, that is valued in the concrete case.
30

[pt] ANÁLISE DE PROBLEMAS TRIDIMENSIONAIS SOLO-ESTRUTURA PELO MÉTODO DOS ELEMENTOS FINITOS NO DOMÍNIO DE FOURIER / [es] ANÁLISIS DE PROBLEMAS TRIDIMENSIONALES SUELO-EXTRUCTURA POR EL MÉTODO DE LOS ELEMENTOS FINITOS EN EL DOMINIO DE FOURIER / [en] THREE-DIMENSIONAL ANALYSIS OF SOIL-STRUCTURE PROBLEMS USING THE FINITE ELEMENT METHOD IN THE FOURIER DOMAIN

JANAINA VEIGA CARVALHO 03 August 2001 (has links)
[pt] Este trabalho estuda problemas geotécnicos e de interação solo-estrutura utilizando o método dos elementos finitos acoplado com a transformada de Fourier. Pela aplicação da transformada de Fourier, as equações diferenciais que governam o problema elástico linear, com as correspondentes condições de contorno, são reescritas no plano de Fourier, permitindo que um problema de natureza tridimensional possa ser numericamente analisado por uma discretização bidimensional. Esta técnica foi empregada neste trabalho para certos problemas de engenharia, como dutovias, túneis e fundações tipo radier, onde a geometria e os parâmetros dos materiais mantêm-se constantes ao longo do eixo longitudinal do corpo, porém admitindo-se variações espaciais no carregamento imposto ao sistema, gerando , assim, um estado tridimensional de tensões. Alguns elementos de interface, com formulação publicada na literatura, foram também considerados na implementação computacional, visto que em problemas de interação solo- estrutura o comportamento do sistema é bastante influenciado pelas propriedades e características mecânicas do solo imediatamente vizinho à estrutura. Os exemplos numéricos apresentados são comparados, sempre que possível, com os resultados obtidos por outra solução analítica ou numérica, procurando discutir as vantagens e limitações do acoplamento da transformada de Fourier com o método dos elementos finitos para a análise de determinada classe de problemas geotécnicos tridimensionais. / [en] In this work some geotechnical and soil-structure interaction problems are studied using the finite element method coupled with a Fourier transform technique. For linear elastic problems, Fourier transforms are applied to the governing field equations, thus enabling that some specific tridimensional problems can be analyzed using a 2D finite element mesh. In conventional finite element applications, a 3D discretization is usually required, but difficulties associated with the preparation of the finite element mesh and the involved computational efforts prevent, in general, the use of a true 3D model. The integral transform method is used in this research for the analysis of some very common problems in geotechnical engineering, such as piping systems, raft foundations and tunnels, where the geometry and the soil profile may be considered constant along a coordinate direction. The applied loading, however, can assume any possible surface distribution, which does not allow to treat the problem under the plane strain assumptions. Some special finite elements presented in the literature, called joint or interface elements, are also incorporated into the finite element computational program written in this research, given that for soil-structure interaction problems the material behavior at the common interface may greatly affect the entire system results. Some numerical examples are presented, and their numerical results are compared, whenever possible, with other solutions obtained using analytical or other numerical technique. Advantages and limitations of the integral transform method to solve tridimensional geomechanics problems are also discussed in this work. / [es] Este trabajo estudia problemas geotécnicos y de interacción suelo-extructura utilizando el método de los elementos finitos acoplado con la transformada de Fourier. Por la aplicación de la transformada de Fourier, las ecuaciones diferenciales que goviernan el problema elástico lineal, con las correspondentes condiciones de contorno, son reescritas en el plano de Fourier, permitiendo que un problema de naturaleza tridimensional pueda ser numericamente analizado por una discretización bidimensional. Esta técnica fue utilizada en este trabajo para ciertos problemas de Ingeniería, como canales, túneles y fundaciones tipo radier, donde la geometría y los parámetros de los materiales se mantienen constantes a lo largo del eje longitudinal del cuerpo, aunque se admiten variaciones espaciales en la carga impuesta al sistema, generando , así, un estado tridimensional de tensiones. En la implementación computacional fueron considerados algunos elementos de la interfaz, con formulación publicada en la literatura, ya que en problemas de interacción suelo-extructura, el comportamiento del sistema está bastante influenciado por las propiedades y características mecánicas del suelo imediatamente vecino a la extructura. Los ejemplos numéricos presentados se compararon, siempre que fue posible, con los resultados obtenidos por otra solución analítica o numérica, discutiendo las ventajas y limitaciones del acoplamiento de la transformada de Fourier con el método de los elementos finitos para el análisis de determinada clase de problemas geotécnicos tridimensionales.

Page generated in 0.0609 seconds