Spelling suggestions: "subject:"etching"" "subject:"fetching""
301 |
Estudo aleatório e controlado do uso clínico de um primer autocondicionante na colagem de bráquetes ortodônticos / Bond failure rates with a self-etching primer: a randomized controlled trialJulio Orrico de Aragão Pedra e Cal Neto 27 January 2009 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O uso de primers autocondicionantes tem sido proposto como uma alternativa para a redução de passos clínicos. O objetivo deste estudo clínico aleatório e controlado foi avaliar a performance de um sistema autocondicionante (Transbond Plus Self-Etching Primer, 3M Unitek - SEP) comparado a um sistema multipasso convencional (Transbond XT, 3M Unitek - TBXT) de colagem ortodôntica, durante um período de 12 meses. Vinte e oito pacientes participaram deste estudo, sendo estes alocados aos grupos SEP ou TBXT de forma aleatória, através de randomização em bloco. Um total de 548 bráquetes metálicos (Micro-Arch, prescrição Alexander, GAC International, Bohemia, NY) foram colados com uso da pasta adesiva Transbond XT (3M Unitek), sendo todos os produtos manuseados de acordo com as recomendações dos fabricantes. Foram totalizados 276 bráquetes no grupo controle e 272 no segundo. Curvas de sobrevivência Kaplan-Meier e o teste log-rank (p<0,05) foram utilizados para comparar o percentual de falhas adesivas para as duas técnicas. Ao final do período foram verificadas trinta e duas falhas adesivas (bráquetes descolados), sendo 19 (6,98%) falhas quando utilizado o primer autocondicionante (SEP) e 13 (4,71%) quando usado o primer convencional (TBXT). Não houve diferença significante entre a sobrevivência dos bráquetes entre os dois grupos avaliados (log-rank test, p=0,311). Quando a influência de gênero do paciente, arco dentário e tipo dentário (anterior ou posterior) foram analisados, somente o tipo dentário foi achado significante. Bráquetes de dentes posteriores apresentaram uma maior probabilidade de falha adesiva que os colados em dentes anteriores (p=0,013) Os autores concluem que o primer autocondicionante pode ser utilizado para colagem direta de bráquetes ortodônticos sem que sua sobrevivência clínica seja afetada. / The use of self-etching primers is presented as an alternative to shorten the clinical bonding steps. The purpose of this clinical trial was to evaluate over a 12-month period the performance of a self-etching system (Transbond Plus SEP, 3M Unitek - SEP) compared with a conventional multi-step system (Transbond XT, 3M Unitek - TBXT). Twenty-eight randomly selected patients were included in this study, each being randomly assigned to TBXT or SEP group. A total of 548 brackets were bonded following the manufacturers instructions, using Transbond XT adhesive paste. The survival rate of brackets were estimated with Kaplan-Meier analysis. Bracket survival distributions with respect to bonding procedure, tooth location, dental arch and patient gender were compared with log-rank test. The failure rates of the TBXT and SEP group were 4.71 and 6.98 per cent respectively. No significant differences in the survival rate were observed between the bonding procedures (p=0.311). When the tooth location, dental arch and patient gender were analysed, only the tooth location was found to be significant. Posterior brackets were more likely to fail than the anterior brackets (p=0.013). Both systems had low bonding failure rates and can be considered adequate for orthodontic bonding needs.
|
302 |
Nanowire Specialty Diodes for Integrated ApplicationsJanuary 2014 (has links)
abstract: Semiconductor nanowires are important candidates for highly scaled three dimensional electronic devices. It is very advantageous to combine their scaling capability with the high yield of planar CMOS technology by integrating nanowire devices into planar circuits. The purpose of this research is to identify the challenges associated with the fabrication of vertically oriented Si and Ge nanowire diodes and modeling their electrical behavior so that they can be utilized to create unique three dimensional architectures that can boost the scaling of electronic devices into the next generation. In this study, vertical Ge and Si nanowire Schottky diodes have been fabricated using bottom-up vapor-liquid-solid (VLS) and top-down reactive ion etching (RIE) approaches respectively. VLS growth yields nanowires with atomically smooth sidewalls at sub-50 nm diameters but suffers from the problem that the doping increases radially outwards from the core of the devices. RIE is much faster than VLS and does not suffer from the problem of non-uniform doping. However, it yields nanowires with rougher sidewalls and gets exceedingly inefficient in yielding vertical nanowires for diameters below 50 nm. The I-V characteristics of both Ge and Si nanowire diodes cannot be adequately fit by the thermionic emission model. Annealing in forming gas which passivates dangling bonds on the nanowire surface is shown to have a considerable impact on the current through the Si nanowire diodes indicating that fixed charges and traps on the surface of the devices play a major role in determining their electrical behavior. Also, due to the vertical geometry of the nanowire diodes, electric field lines originating from the metal and terminating on their sidewalls can directly modulate their conductivity. Both these effects have to be included in the model aimed at predicting the current through vertical nanowire diodes. This study shows that the current through vertical nanowire diodes cannot be predicted accurately using the thermionic emission model which is suitable for planar devices and identifies the factors needed to build a comprehensive analytical model for predicting the current through vertically oriented nanowire diodes. / Dissertation/Thesis / Ph.D. Electrical Engineering 2014
|
303 |
Emprego dos policarbonatos makrofol-de e CR-30 em radiografia com neutronsPEREIRA, MARCO A.S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:25:48Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:33Z (GMT). No. of bitstreams: 1
11313.pdf: 4364467 bytes, checksum: 80dca67e716c2de36cf87cbbab397c48 (MD5) / Dissertacao (Mestrado) / IPEN/D / Intituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP
|
304 |
Análise da resistência de união adesiva de retentores intrarradiculares metálicos e estéticos cimentados em condutor irradiado com laser de diodo de alta potência (830mm) / Analisis of bond strength in estectics and metal posts cemented in root canals irradiated with high power diode laser (830mm)STREFEZZA, CLAUDIA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:59Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:51Z (GMT). No. of bitstreams: 0 / O objetivo deste estudo foi avaliar, in vitro, a resistência de união de retentores intrarradiculares previamente irradiada com laser de diodo em alta intensidade (λ= 830 nm), tanto em regime contínuo como pulsado. Foram utilizados retentores intrarradiculares metálicos ou de fibra de vidro, cimentados com fosfato de zinco ou cimento resinoso auto-condicionante. Assim, as variáveis analisadas foram o regime de irradiação, o tipo de retentor intrarradicular e o tipo de agente cimentante na resistência de união. Estas variáveis foram analisadas, in vitro, nos 3 terços radiculares (cervical, médio e apical) de 90 dentes humanos endodonticamente tratados, preparados para receber retentor intrarradicular e irradiados com laser de diodo em alta intensidade (830 nm). Após a irradiação os retentores foram cimentados com cimento de fosfato de zinco ou com cimento resinoso autocondicionante. As raízes foram seccionadas por meio de cortes transversais dos terços cervical, médio e apical, obtendo-se, assim, seis amostras de cada raiz. Cada uma das amostras foi submetida ao ensaio de resistência de união de maneira cega. Conclui-se que a resistência mecânica à compressão de retentores intrarradiculares em dentina previamente irradiada com laser de diodo de alta intensidade (λ= 830 nm) apresentou maiores valores na dentina intrarradicular tanto no regime contínuo como pulsado, sendo ligeiramente superior no regime pulsado. Foi possível verificar que, nos terços médio e cervical, a irradiação com laser de diodo pulsado (Pm = 1 W, I = 994 W/cm2) resultou em maiores valores de resistência de união, com ambos os cimentos e ambos os tipos de núcleo. Houve diferença estatisticamente significante nos valores de união nos diferentes terços dos grupos tratados, sendo superior para o terço cervical (p < 0,05). Assim, a técnica de irradiação do conduto com laser de diodo mostrou-se eficaz no aumento da resistência de união de retentores intrarradiculares. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
305 |
Estudo comparativo do condicionamento do esmalte e dentina para a adesao de resinas compostas com os lasers Er:YAG 2,94 micrometros e com o laser Co sub(2) de 9,6 micrometrosMARRACCINI, TARSO M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:47:10Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:33Z (GMT). No. of bitstreams: 1
08291.pdf: 5207950 bytes, checksum: 64c6335bc7b19848a3ba260e8b738aeb (MD5) / Dissertacao (Mestrado) / IPEN/D / Intituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP
|
306 |
Construção e caracterização de um reator indutivo : ICP para corrosão de materiais / Construction and characterization of an inductive reactor : ICP for corrosion of materialBesseler, Edmilson 29 August 2008 (has links)
Orientadores: Peter Jurgen Tatsch, Stanislav A. Moshkalyov / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-11T19:17:46Z (GMT). No. of bitstreams: 1
Besseler_Edmilson_M.pdf: 3143419 bytes, checksum: 2715af82a31f1728537a14b1764455a6 (MD5)
Previous issue date: 2008 / Resumo: Esta dissertação apresenta as etapas do trabalho de construção de um Reator ICP destinado a processos de micro fabricação, mais precisamente, destinado a corrosões profundas de Silício a taxas de corrosões elevadas. O modelamento e as caracterizações do reator ICP foram feitas através de um protótipo e depois aplicadas a um equipamento da LAM Research que funcionava em modo RIE. Este foi adaptado para trabalhar em modo ICP, de acordo com os parâmetros obtidos no protótipo. Para isso, foi necessário a instalação do Equipamento e fornecer toda a infra-estrutura que este necessitava para seu funcionamento. Foram desenvolvidos casadores de impedância para ligação dos geradores de RF à bobina do ICP e do eletrodo de polarização da amostra, controladores de fluxo de gases, chaveadores manuais para válvulas pneumáticas, sistemas de refrigeração e tubulação de vácuo. O plasma foi caracterizado e alguns processos foram realizados com o intuído de mostrar o comportamento com relação à variação de parâmetros como pressão, potência, polarização da amostra, fluxo de gases, tempo de processo, área da lâmina exposta ao plasma e também o comportamento de diferentes tipos de máscaras. O Equipamento também foi preparado para que seja possível a comutação de gases, que futuramente será automática, de modo que se possa realizar corrosões e polimerizações consecutivas, como ocorre em processos Bosch. / Abstract: This dissertation shows the steps to building an ICP Reactor dedicated to micro fabrication process, further to deep etching of Silicon on high rates. The modeling and characterization of ICP Reactor has been done in a prototype and after applied on an RIE equipment from LAM Research, that was adapted to work in ICP mode like the prototype. To do it was necessary equipment installation and give it the infra structure needed to it works. A network matching was developed to connect the RF generator to ICP coil and to the electrode of wafer polarization, such as gas flow controllers, manual switches for pneumatic valves, cooling systems and vacuum pipes. The plasma was characterized and some processes has been realized in order to show the trends against some parameters variation as pressure, power, sample polarization (bias), gas flow, process time, wafer area exposed to the plasma and also the behavior of different kind of masks. The equipment is ready to switch some gases, which will be automatic in the future, to corrosion and polymerization consecutive process as at a Bosch process. / Mestrado / Eletrônica, Microeletrônica e Optoeletrônica / Mestre em Engenharia Elétrica
|
307 |
Resistência à corrosão de amálgamas e de liga à base de gálio, sem e com adesivos, através do método de perda de peso e análise da rugosidade de superfície.Paulo Humaitá de Abreu 10 May 2002 (has links)
Avaliou-se a resistência à corrosão pelos testes de perda de peso em imersão alternada (solução-ar) e as conseqüentes alterações produzidas nas superfícies dos três materiais restauradores (os amálgamas Dispersalloy e Tytin Plus, ambos de alto conteúdo de cobre, respectivamente do tipo fase dispersa e do tipo partícula única, assim como a liga à base de gálio Galloy), não ou associados a dois sistemas adesivos (All-Bond 2 e PAAMA-2), observadas através da medição da rugosidade de superfície. Confeccionou-se dez corpos-de-prova, para cada condição específica, a partir de uma matriz metálica de aço inoxidável contendo cinco cavidades cilíndricas, com 10,7 mm de diâmetro por 3,0 mm de altura cada uma. Após o polimento, como é feito no caso de análises metalográficas, os espécimes foram pesados e levados ao rugosímetro para realizar as medições imediatamente. Estes foram submetidos à imersão alternada, na solução de sulfeto de sódio a 5 %, por um período de 24 horas e novamente foi realizada a pesagem e obtidos os valores de perda de peso. Depois da pesagem, os corpos-de-prova foram levados novamente ao rugosímetro para obtenção dos valores médios de rugosidade de superfície. Os resultados foram registrados e submetidos à análise de variância, a dois critérios, e ao teste de contrastes de Tukey-Kramer. Dos resultados obtidos, conclui-se que todos os espécimes perderam peso e tiveram sua rugosidade de superfície aumentada após a imersão em solução corrosiva; a liga Galloy mostrou valores maiores, tanto no método de perda de peso como no de rugosidade de superfície, quando comparada aos dois amálgamas; a liga Tytin Plus alcançou os melhores resultados; houve diferença estatisticamente significante entre os materiais restauradores, mas não entre os sistemas adesivos utilizados, mostrando comportamentos diferentes dependendo da combinação desses fatores. / The resistance to the corrosion was evaluated through weight loss to an alternated immersion (solution-air) and its consequent changes on the surface of three restoring materials (them amalgams Dispersalloy and Tytin Plus, both with high copper content, respectively dispersion phase and unique particle, as well as the alloy gallium base Galloy), associated or not to two adhesive systems (All-Bond 2 and PAAMA-2), observed by measuring the surface roughness. Ten bodies-of-test were made, for each specific condition, in a metallic matrix os stainlesss steel with five cilindrical cavities, measuring 10,7 mm in diameter and 3,0 mm thickness each one. After polishing, as in the metalographic anal ysis, the specimens were weighed and submitted to the roughness measurer to measuring inicial. These were submitted to an alternated immersion in 5 % sodium sulfide solution, for 24 hours and then the second weighting was performed and obtained the average values of weight loss. A second measure of the surface roughness was then performed. The results were registered and submitted to the variance analysis, to two approaches, and to the test of contrasts of Tukey-Kramer. From the obtained results, it was concluded that all specimens lost weight and there was an increasing roughness surface after immersion in corrosive solution; Galloy showed higher values, both weight loss test and the rougness surface, compared to two amalgams; the alloy Tytin Plus obtained better results; there was significant statistical difference among the restoring materials, but not among adhesive systems, showing different behaviors according to arrangement of these factors.
|
308 |
Fabricação de nanoestruturas de alumina anódica porosa e suas aplicações na síntese de nanomateriais. / Fabrication of nanostructures of porous anodic alumina and its applications in systhesis of nanomaterials.Rina Huamanrayme Bustamante 23 May 2012 (has links)
Nanoestructuras de alumina anódica porosa (AAP) têm sido tradicionalmente fabricadas por duas etapas de anodização a temperaturas relativamente baixas (de 0 até 5°C), e usadas como máscaras ideais para formação de vários materiais nanoestruturados. Neste sentido, o objetivo do trabalho foi estudar sistematicamente a formação e a fabricação de nanoestruturas de AAP autoorganizadas por uma só etapa de anodização e posterior aplicação na síntese de nanopartículas e nanofios metálicos. As nanoestruturas auto-organizadas de AAP foram obtidas por apenas uma etapa de anodização em ácido oxálico (H2C2O4) a temperatura ambiente; diferentemente dos processos convencionais onde são utilizados duas ou mais etapas de anodização. As características estruturais dos filmes de AAP foram moduladas através do controle dos parâmetros da concentração da solução, temperatura e potencial de polarização. O procedimento principal, para a obtenção de AAP auto-organizadas apenas por uma etapa de anodização, foi o pós-processamento de abertura dos poros através de um processo de corrosão química. Os resultados obtidos neste trabalho mostraram que o diâmetro médio dos poros apresentou uma dependência linear com a temperatura, potencial e tempo de corrosão química e foi constante em relação à concentração da solução eletrolítica. No entanto, a análise estrutural via microscopia eletrônica de varredura (MEV), mostrou que a circularidade e a ordem dos nanoporos sobre a superfície anodizada melhoraram com o aumento da concentração do eletrólito. A estrutura de AAP com um arranjo hexagonal de poros regularmente distribuídos foi obtida quando a anodização foi realizada em 0,3M de H2C2O4, a 45V e 20°C de temperatura seguido de uma corrosão química a temperatura de 17°C por 102 minutos. Adicionalmente foram obtidos nanopartículas e nanofios metálicos utilizando-se as nanoestruturas de AAP como moldes. Como os filmes de AAP são isolantes a obtenção das nanopartículas e nanofios foi realizado através de um processo de eletrodeposição de corrente alternada (CA). Os resultados deste trabalho mostraram que nanoestruturas de AAP autoorganizadas podem ser fabricadas por uma etapa de anodização controlando o tempo de corrosão química. Os resultados apresentados neste trabalho mostram-se vantajosos em relação aos reportados na literatura, já que normalmente as nanoestruturas de AAP são obtidas mediante processos de anodização em duas etapas e tempos longos de anodização. / Nanostructures of porous anodic alumina (PAA) have been traditionally manufactured by two steps anodization at relatively low temperatures (0 to 5°C) and used as templates suitable for the formation of various nanostructured materials. In this sense, the goal of this work was the fabrication of self-organized porous Anodic alumina nanostructures (AAP) by a one anodization step and subsequent application in the synthesis of metal nanowires and nanoparticles. The self-organized nanostructures of PAA were obtained by just one anodization step in oxalic acid (H2C2O4) at ambient temperature unlike to conventional processes where they are used two or more anodization steps. The structural characteristics of PAA films were modulated through control of the solution concentration, temperature and potential of polarization. The key procedure to obtain the periodic organized PAA by only one step anodization was the post-processing of pore opening through a process of corrosion chemistry. The results of this work showed that the average diameter of pores presented a linear dependence with temperature, time of chemical corrosion, polarization potential and it was constant relative to the concentration of the electrolyte solution. However, the structural analysis via scanning electron microscopy (SEM) showed that the roundness and the order of nanoporos over the anodized surface improved with the electrolyte concentration increasing. The PAA structure with a hexagonal arrangement of pores was obtained when the anodization was held in 0.3 M of H2C2O4, 45V, and 20°C of temperature followed by a chemical corrosion at 17°C of temperature for 102 minutes. Additionally it was obtained nano particles and nano metal wires using the PAA structures as molds. Since the PAA films are insulating, the nanoparticles and nanowire were obtained through an electrodeposition process using alternating current. The results of this work have shown that self-organized PAA nanostructures can be fabricated by one anodization step controlling the time of chemical etching process. The results presented in this work are advantageous in relation to reported in the literature, since normally the structures of PAA are obtained by two step anodization and for long anodization time.
|
309 |
Effect of pre-etching to enamel and dentin on bond strength and interfacial morphology of different adhesives systems = Efeito do pré-condicionamento ácido do esmalte da dentina na resistência de união e morfologia de interface de diferentes sistemas adesivos / Efeito do pré-condicionamento ácido do esmalte da dentina na resistência de união e morfologia de interface de diferentes sistemas adesivosFreitas, Marcela Santiago, 1987- 21 August 2018 (has links)
Orientadores: Mirela Sanae Shinohara, Mário Fernando de Góes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T23:51:52Z (GMT). No. of bitstreams: 1
Freitas_MarcelaSantiago_M.pdf: 38797129 bytes, checksum: 16869befa66eba198d1cb13ad5c9ac1d (MD5)
Previous issue date: 2013 / Resumo: Estudos mostram que a resistência de união (RU) alcançada pelos sistemas adesivos autocondicionantes em superfície de esmalte pré-condicionado é significativamente maior se comparada aos valores obtidos em esmalte não condicionado. A partir destas evidências, este estudo teve como objetivo avaliar a RU e a morfologia da interface adesiva (MI) em esmalte e dentina de um adesivo autocondicionante de passo único multi-mode e um adesivo autocondicionante de dois passos com e sem pré-condicionamento ácido da superfície comparado a dois sistemas adesivos de condicionamento total, de dois e três passos. Terceiros molares humanos recém-extraídos foram seccionados para obtenção de superfícies planas em esmalte e dentina, as quais foram desgastadas com lixa SiC #600 para padronização da smear layer. Estas amostras foram divididas aleatoriamente em 6 grupos: (SBU) Scotchbond Universal; (SBUcond) SBU précondicionado; (CSE) Clearfil SE Bond; (CSEcond) CSE pré-condicionado; (SBMP) Scotchbond Multi-Purpose; e (EX) Excite F. Os grupos de condicionamento total e os autocondicionantes a serem avaliados com pré-condicionamento receberam a aplicação do ácido fosfórico por 15s em dentina e 30s em esmalte. Todos os sistemas adesivos foram aplicados de acordo com as recomendações dos fabricantes. Em seguida, um bloco de resina composta (Filtek Supreme Plus) foi construído incrementalmente sobre cada superfície preparada para o teste de RU, e para a MI, as superfícies foram restauradas com resina flow (Filtek Z-350 Flowable Restorative) formando um "sanduíche", de esmalte ou dentina. Após 24h, para avaliação da RU, as amostras foram seccionadas em palitos com área transversal de 0,8mm2 e submetidos ao teste de microtração com velocidade de 1,0mm/min. Os resultados foram analisados estatisticamente pelos testes one-way ANOVA e Fisher's PLSD (?=0.05) e os padrões de fratura analisados em Microscopia Eletrônica de Varredura (MEV). Para análise da MI, duas amostras de cada grupo foram incluídas em resina epóxica, polidas e observadas em MEV. Para esmalte, os resultados de RU mostraram que o SBUcond e CSEcond obtiveram os maiores valores, seguidos dos grupos SBMP, SBU e CSE que não apresentaram diferenças entre si. O grupo EX obteve os menores valores comparados aos outros grupos. Na análise da MI, os grupos SBUcond e CSEcond apresentaram nítidas extensões do adesivo penetrado no esmalte desmineralizado, semelhante aos sistemas de condicionamento total. Já para dentina, os resultados de RU mostraram que o condicionamento ácido prévio diminuiu significativamente os valores de RU dos sistemas autocondicionantes. Os maiores valores foram obtidos pelo SBU, CSE e SBMP, com valores de RU estatisticamente equivalentes entre si. Como em esmalte, o sistema adesivo EX obteve os menores valores. A análise em MEV da MI mostrou que o condicionamento prévio da dentina com adesivos autocondicionantes forma uma camada híbrida mais espessa com formação de tags resinosos, semelhantes aos sistemas adesivos de condicionamento total. Pode-se concluir que em esmalte, o condicionamento prévio aumentou significativamente os valores de RU para os sistemas autocondicionantes. Contudo, estes sistemas adesivos não apresentaram diferença estatística do adesivo convencional SBMP. E para dentina, o pré-condicionamento dos adesivos autocondicionantes diminuiu significativamente os valores de RU, entretanto, os valores de SBUcond não foram diferentes significativamente dos obtidos pelo sistema adesivo convencional SBMP / Abstract: Studies show that the bond strength (BS) achieved by self-etching adhesive systems on pre-etched enamel surface is significantly higher compared with the values obtained on unetched enamel. From this evidence, this study aimed to assess the BS and morphology of the adhesive interface (AI) on enamel and dentin of a one-step self-etching adhesive multi-mode and a two-step selfetching adhesive with and without pre-etching of surface compared with two totaletching adhesive systems, two and three steps. Recently extracted human third molars were sectioned to obtain flat surfaces in enamel and dentin, which were ground with #600 SiC sandpaper to standardize the smear layer. These samples were randomly assigned into 6 groups: (SBU) Scotchbond Universal; (SBU-et) SBU pre-etched; (CSE), Clearfil SE Bond, (CSE-et) CSE pre-etched; (SBMP) Scotchbond Multi-Purpose, and (EX) Excite F. The groups total-etching and selfetching to be evaluated with pre-etching received the application of phosphoric acid for 15s in dentin and 30s in enamel. All adhesive systems were applied according to manufacturers' recommendations. Then, a block of composite resin (Filtek Supreme Plus) was constructed incrementally on each surface prepared for BS testing. For AI, the areas were filled with flowable resin (Filtek Flowable Restorative Z-350) forming a "sandwich" of enamel or dentin. After 24 hours, to review the BS, the specimens were sectioned into sticks with cross-sectional area of 0.8mm² and submitted to microtensile test at a speed of 1.0mm/min. The results were statistically analyzed by one-way ANOVA test and Fisher's PLSD (?=0.05) and fracture patterns were analyzed through Scanning Electron Microscopy (SEM). For analysis of AI, two samples from each group were embedded in epoxy resin, polished and observed through SEM. For enamel, the results of BS showed that SBU-et and CSE-et obtained the highest values, followed by SBMP groups, SBU and CSE with no differences among them. The EX group obtained the lowest values of all other groups. In the analysis of AI, and CSE-et and SBU-et groups showed sharp tag extensions of the adhesive penetrated in the demineralized enamel, similar to total-etching systems. As for dentin, BS results showed that acid etching significantly reduced the BS values of self-etching systems. The highest values were obtained by the SBU, CSE and SBMP with BS values statistically equivalent to each other. As in enamel, the adhesive system EX obtained the lowest values. SEM analysis showed that BS for pre-etched dentin with selfetching adhesive forms a thicker hybrid layer with resin tags formation, similar to total-etching adhesive systems. It can be concluded that on enamel, the preetching significantly increased BS for self-etching systems. However, these adhesive systems showed no statistical difference from conventional adhesive SBMP. And to dentin, pre-etching of sel-etching adhesives significantly reduced BS, however, SBU-et values were not significantly different from those obtained by the conventional adhesive system SBMP / Mestrado / Dentística / Mestra em Materiais Dentários
|
310 |
Corrosion Characteristics of Magnesium under Varying Surface Roughness ConditionsYayoglu, Yahya Efe 03 November 2016 (has links)
The biggest challenge with magnesium alloy biodegradable implants is the rapid corrosion at the earlier stages of the healing process after implantation. In this research, the impact of surface roughness generated by different means on the corrosion rate of AZ31 magnesium alloy in a simulated biologic environment is investigated. In order to perform accurate experimentation, an in vitro setup is assembled that simulates the human body environment accurately has been prepared using Schinhammer’s in vitro immersion testing setup and Kokubo’s Simulated Body Fluid (SBF). For the immersion test of Mg in SBF, several surface texture groups of Mg have been prepared and submerged into the in vitro tank. The Mg samples’ comparative analysis has been made in terms of corrosion rate, total weight loss and hydrogen gas evolution within a span of 7 days for the first experiment to narrow down the scope and 14 days for the follow up experiment. After 14 days of in vitro immersion test with varying roughness and hydrophobic modifications such as Cytop coating and stearic acid modification, it has been observed that the roughness group created by etching in aqueous NaCl solution for three minutes, shows better corrosion resistance compared to the polished control group. Hydrophobic modifications on the surfaces did not affect the corrosion behavior significantly.
|
Page generated in 0.0518 seconds