• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 66
  • 3
  • 2
  • 1
  • Tagged with
  • 81
  • 81
  • 65
  • 56
  • 15
  • 12
  • 12
  • 11
  • 9
  • 9
  • 8
  • 8
  • 8
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Neutralização de drenagem ácida de minas com escória de aciaria elétrica do forno-panela

Amaral, Fábio Augusto Dornelles do January 2007 (has links)
A drenagem ácida de minas (DAM) é formada quando certos minerais sulfetados são expostos a condições de oxidação. A DAM é normalmente associada com a mineração de carvão, principalmente de depósitos de rejeitos de carvão, que possuem alta concentração de pirita (FeS2). A neutralização da DAM usando materiais alcalinos, como calcário e escórias de aciaria é uma das técnicas utilizadas para remediação deste problema. Assim, o objetivo deste trabalho foi estudar o desempenho da escória de aciaria elétrica do forno-panela na neutralização da DAM em leitos de percolação em comparação com calcário, material tradicionalmente empregado para tal fim. A metodologia de trabalho consistiu na construção de dois sistemas em escala de laboratório, um leito em canal aberto e um reator de leito empacotado. Estudos foram conduzidos para avaliar a capacidade de neutralização e a qualidade do efluente tratado, considerando os seguintes parâmetros: pH, Fe, Al, Cr, Mn, Zn, Ca, Mg, dureza, sulfatos, condutividade e efeitos toxicológicos para microcrustáceos e peixes. Adicionalmente, foram conduzidos estudos de caracterização da escória antes e após aplicação na neutralização da DAM, visando sua futura destinação. O uso de reator de leito empacotado para tratamento da DAM obteve melhores resultados do que o sistema de canal aberto. O reator evita a percolação do efluente por caminhos preferenciais, aumentando a relação volume tratado/volume de leito. Os ensaios realizados com a escória do forno-panela no reator de leito empacotado demonstraram que esse material apresenta uma alta basicidade, permitindo equalização do efluente de saída para que seja descartado na faixa neutra de pH com a remoção dos metais, enquanto com calcário a remoção dos metais foi parcial, ficando o Fe e Mn com valores acima do permitido pela legislação para o descartes de efluentes. Em ambos os casos, o efluente tratado não apresentou toxicidade. Um dos problemas identificados, para ambos os materiais, foi o recobrimento das partículas pelos hidróxidos metálicos na superfície dos materiais, que reduziu a vida útil dos sistemas e o volume de efluente tratado. O ensaio de expansibilidade demonstra que a escória do forno-panela, na sua forma original, apresenta característica expansiva. Após a neutralização do efluente, a escória apresentou expansão menor que o limite estabelecido na norma ASTM C1260, o que poderia viabilizar sua utilização como agregado na construção civil. Os estudos realizados neste trabalho permitiram concluir que o uso de escórias do forno-panela para neutralização de DAM é uma solução, no sentido de melhorar a qualidade da água em depósitos de rejeitos de carvão, possibilitando um destino para a escória de aciaria elétrica após o tratamento da DAM. / The acid mine drainage (AMD) is formed when certain sulfide minerals are exposed to oxidizing conditions. The AMD is commonly associated with coal mining, especially in coal waste deposits that contain high pyrite (FeS2) concentration. The neutralization of AMD using alkaline materials, like limestone and steel slag is one of the useful remediation techniques. The aim of this work was to study the performance of an electric steel slag of a ladle furnace in the neutralization of the AMD in a percolation bed in a comparative way with limestone, material normaly used for this purpose. The methodology of this work is based in the set up of two systems at labotatory scale, one with open channel bed and the other with bed packed reactor. The studies were directed in order to evaluate the neutralization capacity and the quality of the treated effluent, considering the following parameters: pH, Fe, Al, Cr, Mn, Zn, Ca, Mg, hardness, sulphate, conductivity, and toxicological efects to microcrustacean and fish. Addicionaly, some studies was carried out to caracterize the slag before and after application in the neutralization of the AMD, looking for a future destination. The use of the packed bed reactor for the AMD treatment showed better results than the open channels. The reactor avoids the percolation of the effluent to preferential ways, increasing the volume treated/volume of the bed ratio. The tests carried out with slag of the ladle furnace in the packed bed reactor proves that this material have great basicity allowing the equalization of the effluent output to be discharged in a neutral pH degree with metals removal, while with limestone the metals upstake is partial, remainig Fe and Mn with values above than the allowed by the legislation to effluent discharge. In both cases, the efluent didn’t show toxicity. One of the identified problems to both materials was the metalic hidroxid recovering in the surface, reducing the useful life of the system and the volume of treated effluent. The expansibility tests showed that the ladle furnace slag in the original form have expansive characterists. After the neutralization of the effluent, the slag expansion remains below of the standard border ASTM C1260, and could be possible the use as an aggregate in the civil construction. The results showed in this work allows the conclusion that the use of the ladle furnace slag for neutralization of the AMD is a possible solution to improve the water quality in coal waste deposits.
32

Substituição de lubrificantes grafíticos oleosos por aquosos em forjaria e seus impactos no efluente industrial

Reckziegel, Viviana Nedel January 2017 (has links)
Dentre as atividades realizadas pelas indústrias metalúrgicas, destaca-se o forjamento, onde o aço é processado em prensas sob altas temperaturas, resultando na conformação do mesmo no formato desejado. Durante o forjamento, é necessária a aplicação de um lubrificante sobre a peça a fim de reduzir o atrito metal-metal, possibilitando a remoção da peça forjada do interior da matriz. O lubrificante também tem a função de arrefecer, proteger e prolongar a vida útil das matrizes. O lubrificante à base de grafite, por possuir baixo custo, é o mais comum, sendo empregado em cerca de 80% das forjarias. Esses lubrificantes são, historicamente, produzidos em base óleo e, atualmente, também em base água. Após alguns ciclos no processo de conformação, esses lubrificantes são descartados e se juntam à água de lavagem de máquinas, matrizes, pisos e demais águas residuais, gerando um efluente de considerável complexidade que precisa ser tratado a fim de que sejam atendidos os parâmetros de emissões estabelecidos pela legislação. Neste contexto, o objetivo geral desta pesquisa foi desenvolver um tratamento para efluente oriundo da forjaria empregando lubrificantes grafíticos em base água. Amostras de efluentes foram coletadas e caracterizadas em relação aos parâmetros previstos na licença de operação (LO) - pH, sólidos suspensos, sulfetos, DQO, DBO, P, N, Al, B, Pb, Cu, Fe, Ni, Zn e óleos e graxas. Estudos mais detalhados foram realizados em uma amostra, onde se mediram a tensão superficial, a distribuição granulométrica, o potencial zeta e o ângulo de contato entre as fases grafite/água/ar. Essa amostra foi submetida a estudos de tratamento de efluentes por coagulação-floculação seguido de sedimentação ou flotação por ar dissolvido para a remoção dos sólidos suspensos. O lodo gerado foi caracterizado em termos do teor de água e a fase sólida em relação a análise imediata, composição elementar, composição cristalina e poder calorífico. Os resultados demonstraram que o efluente de forjaria base água apresenta uma alta concentração de sólidos suspensos, basicamente partículas de grafite na faixa granulométrica de 1,9 a 13,6 μm. O processo de tratamento do efluente deve iniciar pela remoção do material suspenso, que pode ser realizado por coagulação-floculação. A coagulação foi realizada com sucesso empregando uma concentração de 360 mg Al/L na forma de PAC e 25 mg/L de polímero floculante (poliacrilamida catiônica). Testes com coagulantes a base de ferro também foram realizados com resultados satisfatórios, mas apresentando coloração ao final do tratamento. A separação dos flocos pode ser realizada tanto por sedimentação como por FAD, entretanto a alta concentração de sólidos exige deste último uma alta taxa de reciclo e uma pressão de saturação elevada. O lodo gerado do tratamento em laboratório, tanto PAC quanto cloreto férrico, apresenta teores de carbono acima de 70%. O material é enriquecido em grafite, o que abre um leque de possibilidades para sua destinação, que pode ser em: lubrificantes, eletrodos, material energético para cimenteiras e termoelétricas e síntese de diamantes. A análise elementar demonstrou um teor de cinzas de 20%, teor de matéria volátil de 8% e carbono fixo de 72%. O poder calorífico é da ordem de 6200 cal/g. Testes em escala industrial comprovaram a eficiência do tratamento por coagulação-floculação com PAC e polímero catiônico, seguido das etapas de sedimentação e filtração, com valores de eficiência de tratamento superiores a 90% para a maioria dos parâmetros previstos na licença de operação. Conclui-se que há benefícios operacionais, ambientais e econômicos na substituição do lubrificante de grafite base óleo pelo lubrificante base água, pois há a redução da carga poluidora, simplificação do processo de tratamento, economia em reagentes e a possibilidade de obtenção de um lodo rico em grafite. / Among the activities performed by metallurgical industries, forging excels, where the steel is processed in presses using high temperatures, resulting in a conformation of the desired format. During forging, it is necessary to apply a lubricant over the part in order to reduce metal-to-metal friction, making it possible to remove the forged part from the inner die. Lubricant also has the function of cooling, protecting and prolonging the life of the dies. Because graphite based lubricant has the lowest cost, it is the most common lubricant, being used in about 80% of the forging. Historically, these lubricants have been produced on an oil-based basis and are now also produced in based water. After a few cycles in the forming process, these lubricants are disposed and are mixed to the water of washing the machines, dies, floors and other waste water. It generates an effluent of considerable complexity that needs to be treated in order to meet the emission parameters established by the agency laws. In this context, the objective of this research was to develop a treatment for the effluent from the forging using graphite water based lubricants. Samples of the effluent were collected and characterized in the parameters of the operating license (LO) - pH, suspended solids, sulfides, COD, BOD, P, N, Al, B, Pb, Cu, Fe, Ni, Zn and oils and greases. More detailed studies were carried out in one sample, where were measured surface tension, particle size distribution, the zeta potential and contact angle between the graphite / water / air phases. This sample was submitted to effluent treatment by coagulation-flocculation followed by sedimentation or flotation by dissolved air for the removal of suspended solids. The sludge generated was characterized in terms of the water content and the solid phase in immediate analysis, elemental composition, crystalline composition and calorific value. The results showed that the water based forging effluent presents a high concentration of suspended solids, basically graphite particles in the size range of 1.9 to 13.6 μm. The treatment of the effluent should begin by the removal of the suspended material, which can be carried out by coagulation-flocculation. Coagulation was successfully performed using a concentration of 360 mg Al / L in PAC (aluminum polychloride) and 25 mg / L of flocculating polymer (cationic polyacrylamide). Tests with iron-based coagulants were also performed with satisfactory results, but presented coloration at the end of treatment. The separation of the suspension can be achieved either by sedimentation or by DAF (Dissolved Air Flotation). However the high concentration of solids requires a high recycle rate and a high saturation pressure. The sludge generated from the laboratory treatment, both PAC and ferric chloride, contained carbon above 70%. The material is enriched in graphite, which opens a range of possibilities for its destination, which can be in: lubricants, electrodes, energy material for cement and thermoelectric and diamond synthesis. The elemental analysis showed an ash content of 20%, volatile material content of 8% and fixed carbon of 72%. The calorific value is of the order of 6200 cal/g. Industrial scale tests proved the efficiency of the coagulation-flocculation treatment with PAC and cationic polymer, followed by sedimentation and filtration steps, with efficiency values above 90% for most of the parameters provided in the operating license. It is concluded that there are operational, environmental and economic benefits in the substitution of oil-based graphite lubricant for water-based lubricant, as there is a reduction of the pollutant load, simplification of the treatment process, savings in reagents and the possibility of obtaining a graphite rich sludge.
33

Estudo para otimização do projeto de um sistema de reatores para o tratamento fotoquímico de efluentes industriais. / Study for design optimization of a system of reactors for the photochemical treatment of industrial effluents.

Débora Pereira Coutinho da Silva 09 August 2012 (has links)
O presente trabalho objetivou estudar aspectos relacionados ao projeto de processos de tratamento de águas efluentes industriais baseados em reatores fotoquímicos. Estudou-se uma unidade de tratamento constituída por um reator solar tubular com coletores parabólicos compostos, o qual opera acoplado a um reator com lâmpadas do tipo tanque. O modelo matemático para simulação do processo foi adaptado a partir dos resultados experimentais obtidos em trabalhos anteriores da equipe de pesquisa deste Departamento, principalmente por Ribeiro (2009). O modelo matemático foi validado por meio de simulações para o sistema operando em regime transiente. O modelo matemático foi adaptado à configuração aqui estudada, de modo a poder ser aplicado ao sistema de reatores operando em regime contínuo, isto é, com alimentação e retirada de material constantes ao longo do tempo. Foi realizado, inicialmente, um estudo de sensibilidade desse modelo em relação às variáveis de processo, baseado em simulações para volumes diferentes do reator solar e reator multi-lâmpadas. A otimização do sistema teve o objetivo de selecionar as configurações do sistema que representam mínimo custo, para os diferentes cenários estudados, para uma concentração especificada de contaminante na corrente de saída. O problema de otimização foi baseado no método da função de penalidade, em que a função de restrição é inserida na função objetivo, transformando assim o problema de otimização num problema irrestrito. O procedimento de busca utiliza o Método Simplex modificado de Nelder e Mead. Para os diferentes cenários estudados, foi comprovado que o fator determinante do custo horário de tratamento fotoquímico é o custo do reagente peróxido de hidrogênio, seguido pelo custo de energia elétrica, custo de investimento do reator de lâmpadas, custo de investimento do reator e das bombas e, por último, o custo de investimento do reator solar. A imposição de limites mais rigorosos para a concentração de saída do efluente faz com que o custo de tratamento seja proibitivo. Portanto, nestes casos é mais interessante, do ponto de vista econômico, utilizar primeiro o processo foto-Fenton até o efluente atingir o limite de biodegradabilidade de 300 mgC/L e, em seguida, submeter este efluente ao tratamento biológico (de menor custo). / The aim of the present study was to investigate aspects related to the design of processes for treating industrial wastewater based on photochemical reactors. The system consisted of a solar tubular reactor with compound parabolic collectors, which operates connected to a multi-lamp stirred tank reactor. The mathematical model for simulating the process was adapted from previous results obtained by the research team of this Department, mainly by Ribeiro (2009). The model was validated by comparing simulation and experimental results obtained with a pilot plant operating in transient regime. The mathematical model was adapted to the configuration in this paper, so that it could be applied to the reactor system operating in continuous regime, i.e., with constant flow rate of the input and output streams. A sensitivity analysis of this model was carried out in relation to process variables, based on simulations for different volumes of the solar reactor and multi-lamp reactor. The optimization of the system aimed to select configurations that represent minimum cost for different scenarios studied for a specified output contaminant concentration. The optimization was based on the penalty function method, in which the restriction function was inserted in the objective function, so as to transform the optimization problem into an unconstrained one. The search procedure was based on the modified Simplex method of Nelder and Mead. For the different scenarios studied, it was verified that the determining factor affecting the treatment cost is the cost of hydrogen peroxide, followed by the electricity cost, investment cost of the lamp reactor, investment cost of pumps and of the solar reactor. The treatment cost increases significantly when lower concentration limits are specified for the output stream. Therefore, as a general recommendation, it is more advantageous from the economic point of view to use the photo-Fenton process until the pollutant concentration is decreased to the threshold of biodegradability (adopted as 300mgC/L in the present study) and then submitting it to a biological treatment.
34

Estudo de equilíbrio e cinética da biossorção de cobre (II) por Rhizopus Microsporus. / Equilibrium and kinetics studies of copper (II) biosorption by rhizopus microsporus.

Lucas Makrakis Policarpo 04 August 2015 (has links)
A poluição relacionada a metais pesados tem recebido uma atenção especial devido a sua alta toxicidade, não biodegradabilidade e tendência de acumular-se na cadeia alimentar. Apesar disso, metais pesados também são considerados recursos valiosos, portanto a sua remoção em conjunto com a sua recuperação torna-se ainda mais importante. Este caso aplica-se aos rejeitos de mineração de cobre, os quais oferecem a possibilidade de recuperação do metal e de sua contenção de maneira segura do meio ambiente. Tais rejeitos se caracterizam por ocuparem enormes áreas inundadas e abrigarem soluções diluídas de cobre (II), porém, muitas vezes, acima dos limites seguros. Diversos processos tradicionais de tratamento mostram-se disponíveis para remover o cobre de tais soluções, no entanto, em certas aplicações eles podem ser ineficientes ou muito onerosos. Nesse contexto, a biossorção é uma alternativa interessante. Nesse processo, certos microrganismos, como fungos, bactérias e algas, ligam-se passivamente ao cobre na forma íons ou outras moléculas em soluções. No presente trabalho foi avaliado o potencial de biossorção de íons cobre (II) pela biomassa do fungo Rhizopus microsporus, coletado e isolado da área de rejeitos da Mina do Sossego, na região norte do Brasil. Isotermas de biossorção foram determinadas experimentalmente em bateladas sob temperatura de 25°C, agitação de 150 rpm, concentração de biomassa de 2,0 a 2,5 g/L e tempo de contato mínimo de 4 horas. O pH mostrou ser um fator importante no equilíbrio da biossorção, sendo o valor máximo da capacidade de biossorção de 33,12 mg de cobre / g biomassa encontrado em pH 6. Valores sucessivamente menores são encontrados pela acidificação da solução, sendo o pH 1 considerado adequado para o processo de dessorção, correspondendo a uma capacidade de biossorção de 1,95 mg/g. Modelos de adsorção de Langmuir e de Freundlich ajustaram-se adequadamente às isotermas tanto com pH controlado quanto não controlado. Foi constatado que a troca iônica é um dos mecanismos envolvidos na biossorção do cobre com Rhizopus microsporus. Tanto o modelo de pseudo-primeira ordem quanto o de pseudo-segunda ordem ajustaram-se aos dados cinéticos da biossorção, sendo que o equilíbrio ocorre em aproximadamente 4 horas. A biomassa conservou a capacidade de biossorção ao operar repetidamente em três ciclos de sorção-dessorção. A biomassa viável e a morta não apresentaram diferença estatisticamente significativa na capacidade de biossorção. / Heavy metal pollution has been receiving a special attention because of the high toxicity of these metals, by their non-biodegradability and by their tendency to accumulate throughout the food chain. Nevertheless, heavy metals are also considered valuable resources, hence their recovery and recycle assumes even greater significance. This is the case of copper mining tailings, which offer the possibility of metal recovery while it must be safely contained from the environment. These wastes are characterized by occupying huge flooded areas with very dilute copper (II) solutions, however, in many cases above safe limits. Various traditional treatment methods are available to remove copper from such solutions; however, for certain applications they may be either ineffective or too costly. In this context, biosorption becomes an interesting alternative. In this process, certain microorganisms such as fungi, bacteria and algae, passively bind to the copper ion or other molecules in solution. In the present study the biosorption potential of copper (II) by the fungal biomass of Rhizopus microsporus, collected and isolated from the tailings area of Sossego mine, located in the northern region of Brazil, has been evaluated. Biosorption isotherms have been experimentally determined by batch experiments at a temperature of 25C, agitation speed of 150 rpm, biosorbent concentration in the range of 2.0 to 2.5 mg/L, and contact time of at least 4 hours. The pH has been found to be a determining factor for the sorption equilibrium, a maximum sorption capacity of 33.12 mg copper / g biomass being found at pH 6. Successively smaller values have been found by the acidification of the solution. A pH value of 1 has been considered adequate for the desorption process, which correspond to a biosorption capacity of 1,95 mg/g. Both Langmuir and Freundlich adsorption models fitted well to equilibrium data using both pH methodologies, however the determination coefficient is slightly higher for the former model. It has been found that ion exchange is one of the mechanisms involved in copper (II) biosorption by Rhizopus microsporus. Both pseudo-first and pseudo-second order models have fitted well to biosorption kinetic data. Equilibrium approaches within approximately 4 hours. The biosorbent has proved to maintain its sorption efficiency after three regeneration cycles. Viable and dead biomasses have not exhibited statistically significant difference in sorption behavior.
35

Neutralização de drenagem ácida de minas com escória de aciaria elétrica do forno-panela

Amaral, Fábio Augusto Dornelles do January 2007 (has links)
A drenagem ácida de minas (DAM) é formada quando certos minerais sulfetados são expostos a condições de oxidação. A DAM é normalmente associada com a mineração de carvão, principalmente de depósitos de rejeitos de carvão, que possuem alta concentração de pirita (FeS2). A neutralização da DAM usando materiais alcalinos, como calcário e escórias de aciaria é uma das técnicas utilizadas para remediação deste problema. Assim, o objetivo deste trabalho foi estudar o desempenho da escória de aciaria elétrica do forno-panela na neutralização da DAM em leitos de percolação em comparação com calcário, material tradicionalmente empregado para tal fim. A metodologia de trabalho consistiu na construção de dois sistemas em escala de laboratório, um leito em canal aberto e um reator de leito empacotado. Estudos foram conduzidos para avaliar a capacidade de neutralização e a qualidade do efluente tratado, considerando os seguintes parâmetros: pH, Fe, Al, Cr, Mn, Zn, Ca, Mg, dureza, sulfatos, condutividade e efeitos toxicológicos para microcrustáceos e peixes. Adicionalmente, foram conduzidos estudos de caracterização da escória antes e após aplicação na neutralização da DAM, visando sua futura destinação. O uso de reator de leito empacotado para tratamento da DAM obteve melhores resultados do que o sistema de canal aberto. O reator evita a percolação do efluente por caminhos preferenciais, aumentando a relação volume tratado/volume de leito. Os ensaios realizados com a escória do forno-panela no reator de leito empacotado demonstraram que esse material apresenta uma alta basicidade, permitindo equalização do efluente de saída para que seja descartado na faixa neutra de pH com a remoção dos metais, enquanto com calcário a remoção dos metais foi parcial, ficando o Fe e Mn com valores acima do permitido pela legislação para o descartes de efluentes. Em ambos os casos, o efluente tratado não apresentou toxicidade. Um dos problemas identificados, para ambos os materiais, foi o recobrimento das partículas pelos hidróxidos metálicos na superfície dos materiais, que reduziu a vida útil dos sistemas e o volume de efluente tratado. O ensaio de expansibilidade demonstra que a escória do forno-panela, na sua forma original, apresenta característica expansiva. Após a neutralização do efluente, a escória apresentou expansão menor que o limite estabelecido na norma ASTM C1260, o que poderia viabilizar sua utilização como agregado na construção civil. Os estudos realizados neste trabalho permitiram concluir que o uso de escórias do forno-panela para neutralização de DAM é uma solução, no sentido de melhorar a qualidade da água em depósitos de rejeitos de carvão, possibilitando um destino para a escória de aciaria elétrica após o tratamento da DAM. / The acid mine drainage (AMD) is formed when certain sulfide minerals are exposed to oxidizing conditions. The AMD is commonly associated with coal mining, especially in coal waste deposits that contain high pyrite (FeS2) concentration. The neutralization of AMD using alkaline materials, like limestone and steel slag is one of the useful remediation techniques. The aim of this work was to study the performance of an electric steel slag of a ladle furnace in the neutralization of the AMD in a percolation bed in a comparative way with limestone, material normaly used for this purpose. The methodology of this work is based in the set up of two systems at labotatory scale, one with open channel bed and the other with bed packed reactor. The studies were directed in order to evaluate the neutralization capacity and the quality of the treated effluent, considering the following parameters: pH, Fe, Al, Cr, Mn, Zn, Ca, Mg, hardness, sulphate, conductivity, and toxicological efects to microcrustacean and fish. Addicionaly, some studies was carried out to caracterize the slag before and after application in the neutralization of the AMD, looking for a future destination. The use of the packed bed reactor for the AMD treatment showed better results than the open channels. The reactor avoids the percolation of the effluent to preferential ways, increasing the volume treated/volume of the bed ratio. The tests carried out with slag of the ladle furnace in the packed bed reactor proves that this material have great basicity allowing the equalization of the effluent output to be discharged in a neutral pH degree with metals removal, while with limestone the metals upstake is partial, remainig Fe and Mn with values above than the allowed by the legislation to effluent discharge. In both cases, the efluent didn’t show toxicity. One of the identified problems to both materials was the metalic hidroxid recovering in the surface, reducing the useful life of the system and the volume of treated effluent. The expansibility tests showed that the ladle furnace slag in the original form have expansive characterists. After the neutralization of the effluent, the slag expansion remains below of the standard border ASTM C1260, and could be possible the use as an aggregate in the civil construction. The results showed in this work allows the conclusion that the use of the ladle furnace slag for neutralization of the AMD is a possible solution to improve the water quality in coal waste deposits.
36

Remoção de CO2 em fotobiorreatores utilizando efluentes petroquímicos / CO2 removal in photobioreactors using petrochemical effluents

Scoparo, Carlos Henrique Gimenes 17 August 2018 (has links)
Orientador: Telma Teixeira Franco / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-17T01:46:13Z (GMT). No. of bitstreams: 1 Scoparo_CarlosHenriqueGimenes_M.pdf: 8721395 bytes, checksum: f551ca0f4783c7c7d5825095f8583c89 (MD5) Previous issue date: 2010 / Resumo: Este trabalho é uma contribuição ao desenvolvimento da tecnologia de sequestro de dióxido de carbono através do cultivo de microrganismos unicelulares fotossintetizantes (microalgas e cianobactérias). O aumento da concentração de gases de efeito estufa na atmosfera terrestre, principalmente CO2 formado na queima de combustíveis fósseis, e os temores relativos ao impacto do aquecimento global sobre o equilíbrio climático do planeta têm levado ao desenvolvimento de tecnologias que promovam o sequestro do CO2 emitido e a substituição de combustíveis fósseis por fontes sustentáveis e mais limpas como os biocombustíveis. As microalgas podem ser usadas simultaneamente para promover o sequestro de CO2 durante o crescimento fotossintético e ser a matéria-prima de diversos biocombustíveis, principalmente biodiesel e biogás. Neste sentido, este trabalho objetivou (1) quantificar as taxas de sequestro de CO2 nas fases líquida e gasosa durante o cultivo fotossintético da cianobactéria Aphanothece microscopica Nägeli em fotobiorreator tubular de coluna de bolhas usando como meio de cultura efluente líquido da indústria petroquímica enriquecido com sais; (2) determinar quanto do CO2 sequestrado é efetivamente fixado na biomassa das microalgas; (3) quantificar o impacto do fotoperíodo de 12 horas de luminosidade sobre o desempenho do sistema de cultivo; (4) discutir a viabilidade energética e ambiental do processo. Os resultados experimentais demonstraram equivalência entre as taxas de sequestro de CO2 medidas nas fases líquida e gasosa do sistema, atingindo uma taxa máxima de sequestro de CO2 de 18,7 ± 0,5 mg/L/min em 96 horas de cultivo em batelada sob luminosidade constante. A operação em fotoperíodo de 12 horas de luminosidade levou a uma diminuição de 78% do total de CO2 sequestrado pelo sistema. O balanço parcial das rotas de conversão de carbono demonstrou que aproximadamente apenas 3% do CO2 sequestrado pelo sistema é efetivamente fixado na biomassa formada e que rotas biológicas de fixação de carbono, como a excreção de biopolímeros e liberação de compostos orgânicos voláteis, são predominantes durante o cultivo em detrimento de rotas físico-químicas. A análise de viabilidade energético-ambiental do processo em escala industrial demonstrou que o sistema é capaz de produzir mais energia do que consome durante o processo produtivo / Abstract: This work is a contribution to the development of the technology of carbon dioxide biofixation through the cultivation of unicellular photosynthesizing microorganisms (microalgae and cyanobacteria). The increase of greenhouse gases concentration in the earth atmosphere, mainly CO2 released through the burning of fossil fuels, and the worries about the impact of global warming on the planetary climate equilibrium has taken to the development of CO2 sequestration technologies and the replacement of fossil fuels for cleaner and sustainable fuels such as biofuels. Microalgae can be used simultaneously to promote CO2 sequestration during its photosynthetic growth and be a source of various types of biofuels, mainly biodiesel and biogas. In this regard, this work aimed to (1) quantify CO2 sequestration rates in both liquid and gaseous phases during the photosynthetic cultivation of the cyanobacteria Aphanothece microscopica Nägeli in bubble column photobioreactor using supplemented refinery wastewater as culture medium; (2) determine the percentage of carbon dioxide sequestered that is effectively fixed as microalgal biomass; (3) quantify the impact of intermittent illumination (light cycle of 12 hours) on the culture performance; (4) discuss the energetic and environmental viability of the process. The experimental results showed equivalence between CO2 sequestration rates measured on liquid and gaseous phases of the system. Maximum CO2 sequestration rates of 18.7 ± 0.5 mg/L/min were achieved at 96 hours of cultivation during the continuous illumination experiment. The cultivation in intermittent light regime resulted in a loss of 78% on the CO2 sequestration capacity. The partial balance of the carbon conversion routes showed that only a small fraction (about 3%) of the sequestered CO2 was effectively fixed as microalgae biomass. Additionally, biological conversion routes, as the excretion of biopolymers and the release of volatile organic compounds, seemed to be predominant in the bioreactor rather than physicochemical routes. The energetic and environmental viability analysis of the industrial process showed that the system is able to produce more energy than the amount that is consumed during the production process / Mestrado / Desenvolvimento de Processos Químicos / Mestre em Engenharia Química
37

Filtro anaeróbio seguido de biofiltro aerado submerso = produção de biomassa, conversão de matéria orgânica e de nitrogênio / Anaerobic filter followed submerged aerated biofilter : biomass production, conversion of organic matter and nitrogen

Foco, Mário Luiz Rodrigues, 1981- 12 February 2010 (has links)
Orientador: Edson Aparecido Abdul Nour / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-17T07:54:12Z (GMT). No. of bitstreams: 1 Foco_MarioLuizRodrigues_M.pdf: 3471759 bytes, checksum: 1643f91209e0cdb8cb1ba9502091e4a1 (MD5) Previous issue date: 2010 / Resumo: Sistemas de tratamento concebidos a promover a diminuição das concentrações: de amônia por meio da nitrificação e de Nitrogênio Total (NT) utilizando desnitrificação, são necessidades cada vez maiores para diminuir os impactos causados nos ecossistemas aquáticos quando do aporte de espécies nitrogenadas. Estudou-se o desempenho de um sistema combinado anaeróbio/aeróbio, tratando esgoto sanitário, do complexo hospitalar, da Unicamp, constituído por filtro anaeróbio (FA) seguido de biofiltro aerado submerso (BAS), empregados para a conversão de matéria orgânica e nitrogênio amoniacal, sem a recirculação de biomassa das unidades. A desnitrificação foi avaliada pelo encaminhamento do efluente formado no BAS para o FA, onde em ambiente redutor os doadores de elétrons utilizados foram os compostos orgânicos de rápida biodegradação presentes no esgoto bruto e os ácidos orgânicos formados no processo anaeróbio. O estudo foi dividido em 3 etapas experimentais: 1ª etapa, avaliou-se a conversão de matéria orgânica em dois regimes hidráulicos (TDH total de 23,2 e 20,9 h); 2ª etapa, buscou-se estabelecer o processo e a biomassa relacionada a nitrificação, em dois regimes hidráulicos (TDH total de 18,6 e 13,9 h); 3° etapa, avaliou-se a possibilidade de desnitrificação em dois regimes hidráulicos diferenciados pela ausência e presença de recirculação do efluente tratado pelo BAS, a razão de 0,5 (ambos com TDH total de 18,6 h) A melhor condição operacional (12,1 h no FA e 6,5 h no BAS), apresentou redução das concentrações de DQO, DBO e SST, respectivamente, de 93 ± 3 %, 99 ± 1 % e 98 ± 2 %, com concentrações médias efluentes de 48 ± 9 mg DQO L-1, 5 ± 1 mg DBO L-1 e 3 ± 2 mg SST L-1 (2° etapa), não havendo diferenças significativas (p>0,05) com o desempenho da 3° etapa. Nesta sem recirculação, com TCN de 0,22 ± 0,02 kg N-NH3 m-3 d-1 e TCO de 0,91± 0,31 kg DQO m-3 d-1, alcançou-se nitrificação no BAS de 0,10 ± 0,05 kg N-NO3- m-3 d-1, relação C/N de 4 ± 1,5 e conversão de NH3 de 54 ± 20 %; na 3° etapa com recirculação, com TCN de 0,34 ± 0,05 kg N-NH3 m-3 d-1 e TCO de 0,81 ± 0,16 kg DQO m-3 d-1, alcançou-se nitrificação no BAS de 0,17 ± 0,02 kg N-NO3- m-3 d-1, C/N de 3,4 ± 0,6, conversão de NH3 de 61 ± 20 % e de NT de 43 ± 10 %. No FA em virtude da recirculação de efluente a uma razão de 0,5 a taxa de carregamento de nitrato aplicada foi de 0,024 ± 0,011 kg N-NO3- m-3 d-1 com 89 ± 3 % de conversão. A recirculação do efluente não interferiu na conversão de matéria orgânica, indicando que a configuração e operação proposta está adequada a atender as expectativas sobre sua robustez e possibilidade de reduzir a concentração de carbono orgânico e compostos de nitrogênio, influenciou positivamente em relação a regulação da relação C/N no BAS, porém a recirculação foi insuficiente para promover a regulação da relação C/N-NOx no FA e possibilitar o aumento da conversão de nitrato / Abstract: Treatment systems designed to reduced concentrations ammonia through nitrification and Total Nitrogen (TN) using denitrification, are growing needs to reduce to the impacts on aquatic ecosystems by discharge of nutrients. Evaluated the performance combined anaerobic/aerobic system to treat sewage of the hospital complex, Unicamp, consisting of anaerobic filter (AF) followed by aerated submerged biofilter (ASB) used for the conversion of organic matter and ammonia nitrogen without recirculation of biomass between reactors. Denitrification was evaluated by recirculating part of the effluent formed in the ASB for the AF, in environment reducing where the electron donors used were those organic compounds of rapid biodegradation present in raw sewage and organic acids formed in the anaerobic process. The study was divided into three experimental steps. Step 1, evaluated the conversion of organic matter in two hydraulic regimes (total HRT of 23.2 and 20.9h), step 2, tried to establish the process and biomass related to nitrification in two HRT (18.6 and 13.9h), step 3, evaluated the possibility of denitrification in two HRT distinguished by the absence and presence of recirculation of treated effluent by ASB, ratio of 0.5 (both with HRT of 18.6h) The best operating condition (12.1h in AF and 6.5h in ASB) showed conversion efficiencies of COD, BOD and TSS, respectively, 93 ± 3% 99 ± 1% and 98 ± 2%, with average effluent concentrations of 48 ± 9 mg COD L-1, 5 ± 1 mg L-1 BOD and TSS 3 ± 2 mg L-1 (2nd stage), no differences significant (p>0.05) with the performance of the 3rd step. In this without recirculation, with NLR to 0.22 ± 0.02 kg NH3 m-3 d-1 and OLR 0.91 ± 0.31 kg COD m-3 d-1, was reached in nitrification ASB 0.10 ± 0.05 kg NO3- m-3 d-1, C/N of 1.5 ± 4, and NH3 conversion of 54 ± 20%, while on the 3rd stage with recirculation, with the NLR 0.34 ± 0.05 kg NH3 m-3 d-1 and OLR 0.81 ± 0.16 kg COD m-3 d-1, was reached in ASB nitrification of 0.17 ± 0.02 kg NO3- m-3 d-1, C/N of 3.4 ± 0.6, NH3 conversion of 61% ± 20 and NT 43 ± 10%. In the AF due to the effluent recycle ratio of 0.5 to nitrate loading rate applied was 0.024 ± 0.011 kg NO3- m-3 d-1 with 89 ± 3% conversion. The recirculation did not affect the conversion of organic matter and indicated that the proposed configuration and operation is adequate to meet the expectations of its robustness and ability to reduce the concentration of organic carbon and nitrogen compounds, positively influenced regarding the regulation of C/N ratio in ASB, but this was insufficient to promote the regulation of the C/N-NOx ratio in AF and to increase the conversion of nitrate / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
38

Degradação de fenol por processos eletroquimico foto-assistido em escala piloto / Degradation of fenol using photo-assisted electrochemical process in pilot scale

Baroni, Paula 15 August 2018 (has links)
Orientador: Edson Tomaz / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-15T13:26:06Z (GMT). No. of bitstreams: 1 Baroni_Paula_M.pdf: 2153923 bytes, checksum: 0d73b228cc0146200966eb10e60b81f4 (MD5) Previous issue date: 2010 / Resumo: A degradação de poluentes por biodegradação é um dos processos mais econômicos para o tratamento de compostos orgânicos. Na presença de substâncias tóxicas e recalcitrantes, entretanto, o processo biológico não é capaz de promover a degradação ou pode despender um tempo considerável para que a concentração requerida de um poluente seja alcançada. Os processos eletroquímicos foto-assistidos são uma alternativa ao tratamento de poluentes persistentes, possibilitando inclusive sua completa mineralização, devido à formação de radicais com alto poder de oxidação. O resultado positivo deste processo em diversos estudos levou à realização este trabalho, que tem como objetivo verificar a degradação de fenol em uma escala piloto. Foram utilizados quatro reatores tubulares em série, com área superficial interna de 0,18 m2 cada, revestidos com TiO2/RuO2 (70 %/30 %), que é o catalisador e anodo do sistema. No interior do reator apresenta-se o catodo, uma rede cilíndrica de titânio expandido a uma distância de 3 mm do anodo. Concentricamente ao catodo há um tubo de quartzo, dentro do qual a lâmpada ultravioleta permanece protegida. Os ensaios foram realizados em um volume de 80 L de uma solução de fenol de 100 mg.L-1 e 0,08 mol.L-1 de eletrólito suporte (K2SO4), avaliando-se a degradação de fenol, de carbono orgânico total e a formação dos intermediários de oxidação hidroquinona e benzoquinona, tendo como variáveis independentes no planejamento experimental a densidade de corrente, a vazão e o pH inicial. A densidade de corrente foi a variável mais significativa, sendo que a maior densidade utilizada (95 mA.cm-2) promoveu a melhor degradação, reduzindo 73 % da carga orgânica total e 99 % de fenol. Entretanto, a menor densidade de corrente garantiu maior eficiência energética ao processo. O ensaio com melhor desempenho (40 mA.cm-2; pH = 4,21; vazão = 3650 L.h-1) degradou 61 % de carbono orgânico total e 99 % de fenol, consumindo 2072 kWh por quilograma de carbono orgânico degradado e 1047 kWh por quilograma de fenol degradado, evidenciando a necessidade de otimização do processo. Alguns ensaios utilizando cloreto de sódio como eletrólito para a geração de cloro ativo no meio reacional não mostraram vantagens em relação ao uso de sulfato de potássio (K2SO4) / Abstract: The biodegradation of pollutants is one of the most economical types of treatment of organic wastewater. In the presence of toxic and recalcitrant compounds, however, the biological processes don't promote degradation or may spend considerable time to reach the required concentration of a pollutant. The photo-assisted electrochemical processes are an alternative treatment for recalcitrant pollutants, enabling their complete mineralization, due to the formation of radicals with high oxidation power. This process showed positive outcome for phenol degradation in several studies on laboratory scale, so this work aims to verify its efficiency in a pilot scale. It was used four tubular reactors in series, with inner surface area of 0.18 m2 each one, coated with an oxide layer composed of TiO2 / RuO2 (70% / 30%), which are the system's catalyst and also anode. Inside the reactor is the cathode, a cylindrical screen of expanded titanium, in a distance of 3 mm from the anode. Concentrically to the cathode is a quartz tube, within which the ultraviolet lamp remains protected. The experiments were carried out in 80 L of a 100 mg.L-1 phenol solution and 0.08 mol.L-1 of supporting electrolyte (K2SO4). In the experimental design, the dependent variables were the degradation of phenol, total organic carbon and the formation of the intermediates, hydroquinone and benzoquinone. The effects of current density, flow rate and initial pH on the degradation rate were investigated. The current density was the most significant variable and the highest density used (95 mA.cm-2) provided better degradation, reducing 73% of total organic carbon and 99% of phenol. However, the lower current density brought greater energy efficiency to the process. The best performance (40 mA.cm-2, pH = 4.21, F = 3650 L.h-1) degraded 61% of total organic carbon and 99% of phenol, consuming 2072 kWh per kilogram of organic carbon degraded and 1047 kWh per kilogram of phenol degraded, indicating the need for process optimization. Some tests using sodium chloride as electrolyte for the generation of active chlorine in the reaction, showed no advantages over the use of potassium sulphate (K2SO4) / Mestrado / Desenvolvimento de Processos Químicos / Mestre em Engenharia Química
39

Degradação do herbicida Atrazina utilizando os processos foto-Fenton solar e Fenton / Atrazine degradation by photo-Fenton solar and Fenton processes

Corrêa, Camila Fittipaldi 17 July 2017 (has links)
Submitted by Neusa Fagundes (neusa.fagundes@unioeste.br) on 2018-06-18T13:49:14Z No. of bitstreams: 2 Camila_Correa2017.pdf: 1275223 bytes, checksum: 77569c2521068112f0523744356a06c7 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-06-18T13:49:14Z (GMT). No. of bitstreams: 2 Camila_Correa2017.pdf: 1275223 bytes, checksum: 77569c2521068112f0523744356a06c7 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-07-17 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The population development has affected the consumption increase in agricultural products, which leads to higher agrochemicals consumption. Thus, sprayers washing used in crops during agrochemicals applications has generated highly toxic effluents, consequently there is a great treatment need. Therefore, this research aims at investigating the effects of Fenton process parameters and the efficiency of photo-Fenton and Fenton processes on atrazine herbicide degradation. During this trial two steps were carried out. In the first step, a 2² central composite rotational design (CCRD) containing 3 central and 4 axial points for the Fenton process was proposed, with two factors: concentrations of Fe2+ (2.95, 5, 10, 15, 17.05 mg L-1) and H2O2 (29.5, 50, 100, 150 and 170.5 mg L-1), whose response factor was atrazine degradation. The obtained optimum conditions were Fe2+ = 17.05 mg L-1 and H2O2 = 128 mg L-1, and the maximum degradation was 91.00% in the validation tests. In the second step, kinetic tests were carried out using the best optimum operation conditions obtained at CCRD. The kinetics was investigated, and it reached reductions of 91.76 and 99.14%, respectively, in the Fenton and solar photo-Fenton processes, for a reaction times of 30 and 6 minutes. The behavior of pseudo-first order was observed. Although of the efficient degradation of atrazine, the results have indicated that the established values such as 2.0 μg L-1 of maximum allowed atrazine were not reached by CONAMA 357/2005 (the current Brazilian legislation). Finally, it can be concluded that the processes are promising in atrazine degradation and should be incorporated by farmers as part of the systems for the treatment of their contaminated effluents. / O crescimento populacional vem influenciando o aumento do consumo dos produtos agrícolas e, portanto, há maior consumo de agroquímicos. A lavagem dos pulverizadores utilizados nas aplicações de agroquímicos ocasiona a geração de efluentes altamente tóxicos, os quais necessitam de tratamento. Assim esta pesquisa teve como objetivos investigar os efeitos dos parâmetros operacionais do processo Fenton e a eficiência dos processos foto-Fenton solar e Fenton na degradação do herbicida atrazina. A pesquisa foi realizada em duas etapas. Na primeira etapa, foi proposto um delineamento composto central rotacional (DCCR) 2² contendo 3 pontos centrais e 4 axiais para o processo Fenton, com dois fatores: as concentrações de Fe2+ (2,95; 5; 10; 15; 17,05 mg L-1) e de H2O2 (29,5; 50; 100; 150 e 170,5 mg L-1), cujo fator resposta foi a degradação da atrazina. As condições ótimas encontradas foram de Fe2+ = 17,05 mg L-1 e de H2O2 = 128 mg L-1, e a máxima degradação encontrada foi de 91,00% nos testes de validação. Na segunda etapa, foram realizados testes cinéticos utilizando as melhores condições operacionais obtidas no DCCR. A cinética foi investigada e alcançou reduções de 91,76 e 99,14%, respectivamente, nos processos Fenton e foto-Fenton solar, para os tempos reacionais de 30 e de 6 minutos. Foi também observado comportamento de pseudo-primeira ordem. Apesar da eficiente degradação da atrazina, os resultados indicaram que não foram atingidos os valores estabelecidos como máximo permitido de 2,0 μg L-1 de atrazina pela resolução Conama 357/2005 (legislação brasileira vigente). Portanto, pode-se concluir que os processos são promissores na degradação da atrazina e poderão ser incorporados pelos agricultores como processos de polimento, como parte dos sistemas para o tratamento dos seus efluentes contaminados.
40

Qualidade da água residuária em sistemas de produção e de tratamento de efluentes de suínos e seu reuso no ambiente agrícola / Residual water quality in systems for production and treatment of swine manure and its re-utilization in agricultural environments

Edilaine Regina Pereira 13 March 2006 (has links)
O presente trabalho teve por objetivo avaliar quanti/qualitativamente a água residuária do efluente suinícola no sistema de produção, no sistema de tratamento, e ainda, a reutilização do efluente em cultivo de pastagem do gênero Brachiária decumbens. A pesquisa desenvolveu-se em quatro etapas onde a primeira etapa foi um levantamento das propriedades suinícolas do Estado de São Paulo e suas condições de operacionalidade. Em seguida, escolheu-se uma determinada propriedade a fim de que as próximas etapas pudessem ser conduzidas. Sendo assim, analisou-se a água residuária de todas as fases do sistema criatório de suínos considerando os parâmetros químicos (pH, Al, B, Ba, B, Ca, Cd, Co, Cr, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, Sr e Zn), físicos (sólidos totais, dureza, turbidez e condutividade elétrica), bioquímicos (DBO e DQO) e microbiológicos (coliformes totais e E.coli). Logo após esta etapa, considerouse as mesmas análises para o sistema de tratamento presente na propriedade escolhida. Dos resultados obtidos pode-se concluir a existência de uma situação agravante ao qual se encontra as propriedades suinícolas do Estado de São Paulo frente ao descaso pelo problema ambiental provocada pelo efluente animal. Pelos parâmetros analisados, conclui-se pela segunda etapa desta pesquisa que, pelo elevado fator poluente do efluente de suínos, a aplicação deste na agricultura de forma bruta fica completamente comprometida. Como observado na fase III, há eficiência de remoção dos elementos tóxicos no decorrer do sistema de tratamento, podendo este efluente ser aplicável ao solo e a planta com o devido cuidado de manejo. Para a produtividade, resultados da fase IV comprovam o elevado incremento de massa verde e massa seca obtido nas amostras irrigadas com efluente das lagoas de tratamento, com destaque para a lagoa 2 que apresentaram maior produtividade. / This work aimed to evaluate quantitative and qualitative traits of residual water of swine effluents from pork production system and in treatment system, and also, the effluent reutilization in Brachiaria decumbens pasture. This investigation can be sheared in four steps. First, the management conditions of swine farms in São Paulo State were registered. Following, one farm was chosen in order to carry out the further steps. Thus, residual water from all phases of swine breeding system was analyzed considering chemical (pH, Al, B, Ba, B, Ca, Cd, Co, Cr, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, Sr e Zn); physicals (total solids, hardness, electrical conductivity); biochemical (DBO and DQO) and microbiological parameters (total coliforms and E. coli). Our results showed the worsening situation of swine farms in São Paulo State as a consequence of lacking attention to the environmental problem caused by hog pollution. Throughout the results found in second step of our study, we conclude that the high pollution potential of swine effluents prejudices its agricultural application in large scale. In the third step, we found the efficiency of removing toxic elements from treatment system, which become possible to use (with management cares) this cleaned effluent on soil and plants. For the productivity, in phase IV proved the increase in growth of green matter and dry matter in sample that were irrigated mainly with effluents from lagoon 2 did have increase of productivity.

Page generated in 0.0891 seconds