• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5783
  • 109
  • 97
  • 84
  • 84
  • 83
  • 55
  • 37
  • 29
  • 21
  • 21
  • 18
  • 3
  • 3
  • 1
  • Tagged with
  • 6029
  • 3373
  • 2538
  • 1559
  • 1414
  • 1184
  • 959
  • 777
  • 749
  • 729
  • 672
  • 662
  • 615
  • 611
  • 525
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
921

Mecanismos de reconfiguração dinâmica aplicados ao projeto de um processador de imagens reconfigurável

Boschetti, Marcos Rafael January 2004 (has links)
As modernas aplicações em diversas áreas como multimídia e telecomunicações exigem arquiteturas que ofereçam altas taxas de processamento. Entretanto, os padrões e algoritmos mudam com incrível rapidez o que gera a necessidade de que esses sistemas digitais tenham também por característica uma grande flexibilidade. Dentro desse contexto, tem-se as arquiteturas reconfiguráveis em geral e, mais recentemente, os sistemas reconfiguráveis em um único chip como soluções adequadas que podem oferecer desempenho, sendo, ao mesmo tempo, adaptáveis a novos problemas e a classes mais amplas de algoritmos dentro de um dado escopo de aplicação. Este trabalho apresenta o estado-da-arte em relação a arquiteturas reconfiguráveis nos meios acadêmcio e industrial e descreve todas as etapas de desenvolvimento do processador de imagens reconfigurável DRIP (Dynamically Reconfigurable Image Processor), desde suas origens como um processador estático até sua última versão reconfigurável em tempo de execução. O DRIP possui um pipeline composto por 81 processadores elementares. Esses processadores constituem a chave do processo de reconfiguração e possuem a capacidade de computar um grande número de algoritmos de processamento de imagens, mais específicamente dentro do domínio da filtragem digital de imagens. Durante o projeto, foram desenvolvidos uma série de modelos em linguagem de descrição de hardware da arquitetura e também ferramentas de software para auxiliar nos processos de implementação de novos algorimos, geração automática de modelos VHDL e validação das implementações. O desenvolvimento de mecanismos com o objetivo de incluir a possibilidade de reconfiguração dinâmica, naturalmente, introduz overheads na arquitetura. Contudo, o processo de reconfiguração do DRIP-RTR é da ordem de milhões de vezes mais rápido do que na versão estaticamente reconfigurável implementada em FPGAs Altera. Finalizando este trabalho, é apresentado o projeto lógico e elétrico do processador elementar do DRIP, visando uma futura implementação do sistema diretamente como um circuito VLSI.
922

Modelagem e análise de um dispositivo mitigador de flecha para linhas de transmissão de energia elétrica baseado em ligas com memória de forma

Niemeyer, Rômulo Castro 26 February 2016 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2016. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2016-06-20T15:41:05Z No. of bitstreams: 1 2016_RomuloCastroNiemeyer.pdf: 3666054 bytes, checksum: 677e874d2007f0914f511a0fd84c0027 (MD5) / Approved for entry into archive by Marília Freitas(marilia@bce.unb.br) on 2016-07-30T11:50:46Z (GMT) No. of bitstreams: 1 2016_RomuloCastroNiemeyer.pdf: 3666054 bytes, checksum: 677e874d2007f0914f511a0fd84c0027 (MD5) / Made available in DSpace on 2016-07-30T11:50:46Z (GMT). No. of bitstreams: 1 2016_RomuloCastroNiemeyer.pdf: 3666054 bytes, checksum: 677e874d2007f0914f511a0fd84c0027 (MD5) / Os cabos de transmissão de energia elétrica, em determinadas condições operacionais, sofrem deformações associadas à dilatação térmica e fluência que podem levar a flechas excessivas que infringem as distâncias mínimas estabelecidas por normas de segurança. O objetivo do presente trabalho é explorar a capacidade termomecânica das Ligas com Memória de Forma (Shape Memory Alloys – SMA) para modelar e realizar a análise de um mitigador de flecha para linhas de transmissão de energia elétrica. A SMA se inserem na área de aplicação de materiais inteligentes e sua característica mais marcante é sua capacidade de recuperar uma forma previamente estabelecida quando aquecidos acima de uma determinada temperatura ou quando submetidos a determinados ciclos de carga. A partir de uma concepção já existente foi desenvolvido um modelo para análise e projeto de um dispositivo de mitigação de flecha. O modelo foi aplicado a um estudo de caso. Os resultados mostram que o dispositivo mitigador dimensionado a partir do modelo proposto mostra-se capaz de promover redução de flecha que mantem a distância de segurança prevista pela norma. _________________________________________________________________________________________ ABSTRACT / The electric power transmission cables, under certain operating conditions, suffer deformations associated with thermal expansion and creep that can lead to excessive sags that violate the criteria required by safety standards. The objective of this study is to explore the thermomechanical capacity of alloys with shape memory - SMA - to perform an model and analysis of a sag mitigator for power transmission lines. The SMAs fall into the area of application of smart materials and their most striking feature is its ability to recover a previously established form when heated above a certain temperature or when subjected to certain load cycles. From an existing design was developed a model for analysis and design of an sag mitigation device. This model was applied to a case study. The results show that the mitigating device dimensioned effected a sag reduction thereby maintaining the required safety distance.
923

Estudo experimental e de modelagem matemática do escoamento subterrâneo em uma vertente de zona ripária no bioma Cerrado

Almeida, Andréia de 11 August 2016 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2016. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2016-08-29T15:38:02Z No. of bitstreams: 1 2016_AndréiadeAlmeida.pdf: 10836840 bytes, checksum: e19edfc2959cacefa0a384474d13236c (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-09-02T20:25:33Z (GMT) No. of bitstreams: 1 2016_AndréiadeAlmeida.pdf: 10836840 bytes, checksum: e19edfc2959cacefa0a384474d13236c (MD5) / Made available in DSpace on 2016-09-02T20:25:33Z (GMT). No. of bitstreams: 1 2016_AndréiadeAlmeida.pdf: 10836840 bytes, checksum: e19edfc2959cacefa0a384474d13236c (MD5) / Zonas ripárias possuem papel essencial de conectividade hidrológica entre a vertente e os corpos hídricos, ressaltando a importância da compreensão dos processos hidrológicos que nelas se estabelecem. Diante disso, este trabalho consiste na aquisição de dados geofísicos para caracterização indireta do comportamento da água no solo e a resolução de um modelo numérico bidimensional vertical voltado à simulação do fluxo de água em ambiente de zona ripária. A bacia do córrego Capetinga, localizada na porção sul do Distrito Federal, foi utilizada como área experimental para coleta de dados geofísicos e monitoramento da umidade do solo no período de agosto de 2015 a fevereiro de 2016. Os levantamentos geofísicos foram realizados pelo método elétrico de corrente contínua, com técnica de caminhamento elétrico e arranjo de Wenner, considerando a variação espacial num trecho de 200 m de vertente, totalizando seis linhas de monitoramento (cinco paralelas e uma horizontal ao córrego Capetinga). A equação diferencial que rege o fluxo de água em superfícies de saturação variável foi solucionada por aproximação numérica pelo método de elementos finitos. O imageamento elétrico possibilitou acompanhar a variação espacial e temporal nos valores de resistividade elétrica do solo, como um indicativo do comportamento da água, especialmente no que diz respeito à identificação da zona saturada na vertente. Desse modo, as informações geofísicas permitiram a caracterização das condições iniciais e a verificação dos resultados de carga hidráulica simulados. Com relação à umidade do solo, os métodos gravimétrico, sonda TDR e de blocos de gesso foram aplicados com o intuito de instrumentalizar a obtenção de dados diretos e indiretos e ampliar a escala temporal e espacial de monitoramento do teor de água na zona não saturada. O modelo numérico, por sua vez, apresentou convergência para condutividade hidráulica equivalente a 0,04 m/dia. Nesse caso, os valores de escoamento de base simulados resultaram em ordem de grandeza equivalente àqueles decorrentes do filtro automático de Arnold e Allen (1999). De modo geral, este trabalho contribuiu para a análise do comportamento da água no solo, sendo um passo inicial para compreensão da complexidade dos processos hidrológicos estabelecidos em ambientes de vertente. ________________________________________________________________________________________________ ABSTRACT / Riparian zones have essential role of hydrological connectivity between the hillslope and the streams, emphasizing the importance of understanding the hydrological processes that are established in them. Therefore, this paper presents the development of an experimental design with the acquisition of geophysical data for the indirect characterization of soil water behavior as well as from the resolution of a two-dimensional vertical numerical model focused on the simulation of water flow in the soil environment riparian zone. The watershed of the Capetinga stream, located in the southern part of the Federal District, was used as an experimental area with collection of geophysical data and monitoring of soil moisture during the period from August 2015 to February 2016. Geophysical surveys were conducted through electrical method of direct current resistivity technique and Wenner arrangement, considering the spatial variation in 200 meters of hillslope, totaling six lines monitoring (five parallel and one orthogonal to the Capetinga stream). Differential equation that governs the flow of water in the saturation of surfaces was solved by numerical approximation by finite element method. The electrical resistivity traversing possible to monitor the spatial and temporal variations in the values of electrical resistivity soil, as an indication of the behavior of water, especially identifying the saturated zone along the hillslope. Thus, the information obtained from the geophysical surveys allowed the characterization of the initial conditions and verification of the results of head hydraulic resulting from the simulation of water flow in the model domain. Regarding the soil moisture, the application of gravimetric methods, TDR probe and gypsum blocks was carried out in order to instrumentalize obtaining direct and indirect data and expand the temporal and spatial scale of the water content monitoring in the unsaturated zone. The numerical model, in turn, results had converged by adopting hydraulic conductivity equal to 0.04 m/d. In this case, the simulators base flow values presented order of magnitude equivalent to those resulting from recursive filter Arnold and Allen (1999). Overall, this work contributed to the water of behavior analysis on soil hillslope, being an initial step in understanding the complexity of hydrological processes established in this environment that is a unit of essential landscape at the watershed scale.
924

Estudo das interações intermoleculares de líquido iônicos sob a ótica da química quântica

Oliveira, Ana Gabriela Coelho 05 August 2016 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Química, Programa de Pós-Graduação em Química, 2016. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-09-15T19:00:51Z No. of bitstreams: 1 2016_AnaGabrielaCoelhoOliveira.pdf: 8589095 bytes, checksum: 784128f7152ddd041cb91431101ccb9e (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-11-08T13:55:54Z (GMT) No. of bitstreams: 1 2016_AnaGabrielaCoelhoOliveira.pdf: 8589095 bytes, checksum: 784128f7152ddd041cb91431101ccb9e (MD5) / Made available in DSpace on 2016-11-08T13:55:54Z (GMT). No. of bitstreams: 1 2016_AnaGabrielaCoelhoOliveira.pdf: 8589095 bytes, checksum: 784128f7152ddd041cb91431101ccb9e (MD5) / Líquidos iônicos são sais orgânicos no estado líquido, a temperatura abaixo de 100°C, que apresentam uma série de propriedades características de grande interesse na química e outras áreas afins. Essas propriedades dependem da natureza dos íons pertencentes ao par iônico, resultando em diferentes tipos de interações intermoleculares na estrutura molecular destes compostos, como ligações de hidrogênio e outras forças dispersivas. Neste trabalho foram realizados estudos teóricos acerca do empacotamento de seis líquidos iônicos da classe imidazólio pela aplicação de métodos quantum-mecânicos utilizando a Teoria do Funcional de Densidade (DFT) em conjunto com as técnicas baseadas em modelo de Orbitais Naturais de Ligação (NBO) e Teoria Quântica de Átomos e Moléculas (QTAIM). Dessa forma, a partir das coordenadas cristalográficas dos líquidos iônicos, foram analisados os efeitos da vizinhança molecular, e interpretações do efeito do ânion e da variação do tamanho da cadeia alquila, a partir de propriedades obtidas das estruturas eletrônicas destes compostos, como polarizabilidade, momento de dipolo e deslocalização eletrônicas, relacionando-as com propriedades macroscópicas experimentalmente conhecidas. Por fim, foi constatado um comportamento não-aditivo das polarizabilidades nos sistemas aqui descritos, reforçando ainda mais o papel fundamental que a vizinhança molecular desempenha. _________________________________________________________________________________________________ ABSTRACT / Ionic liquids are organic salts in liquid state, at temperatures below 100°C, that presents a series of characteristic properties of great interest in chemistry and related fields. These properties depend on the nature of the ions associated in the ionic pair resulting in different types of intermolecular interactions in the molecular structure of these compounds, like hydrogen bonds and other dispersive forces. This work carried out theoretical studies about the packing of six ionic liquids of imidazolium class by application of quantum-mechanical method using Density Functional Theory (DFT) in conjunction with techniques based on the model of Natural Bond Orbital (NBO) and Quantum Theory of Atoms in Molecules (QTAIM). Thus, from the ionic liquids crystallographic coordinates, molecular vicinity effects were analyzed and interpretations of the anion effect and the variation of alkyl chain length, the properties acquired from the electronic structures of these compounds, such as polarizability, dipole moment and electronic delocalization, relating to known experimental macroscopic properties. Lastly, it was found that the non-additive behavior of the polarizability in the molecular system depicted in this work, stressing the fundamental role played by the molecular vicinity.
925

Análise de custo-benefício da implantação das redes elétricas inteligentes nas concessionárias de distribuição de energia elétrica do Brasil / Cost-benefit analysis of smart grids implementation in the Brazilan electricity distribution utilities

Vasconcelos, Marcos Venicius Leite 09 December 2016 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2016. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2017-03-23T18:07:41Z No. of bitstreams: 1 2016_MarcosVeniciusLeiteVasconcelos.pdf: 2864727 bytes, checksum: 7743bd46e61d57a8207ecf4b151b4929 (MD5) / Approved for entry into archive by Ruthléa Nascimento(ruthleanascimento@bce.unb.br) on 2017-03-24T18:19:26Z (GMT) No. of bitstreams: 1 2016_MarcosVeniciusLeiteVasconcelos.pdf: 2864727 bytes, checksum: 7743bd46e61d57a8207ecf4b151b4929 (MD5) / Made available in DSpace on 2017-03-24T18:19:26Z (GMT). No. of bitstreams: 1 2016_MarcosVeniciusLeiteVasconcelos.pdf: 2864727 bytes, checksum: 7743bd46e61d57a8207ecf4b151b4929 (MD5) / A implantação das Redes Elétricas Inteligentes (REI) tem resultado em significativos benefícios ao setor de distribuição de energia elétrica em diferentes países. Todavia, os investimentos associados a esta empreitada são volumosos, o que indica a necessidade de uma avaliação de sua viabilidade econômica e, consequentemente, de seus motivadores. Alguns estudos já responderam a essa demanda em nível nacional. Entretanto, ainda não há no Brasil uma análise que incorpore as características específicas das diferentes empresas de distribuição. Nesse contexto, o presente trabalho tem como objetivo executar uma análise do custobenefício da implantação das REI nas diversas concessionárias brasileiras de distribuição. Para tanto, estima-se o Valor Presente (VP) de 3 categorias de custos e 8 de benefícios e, por meio de processos de clusterização e técnica de correlação, identificam-se os motivadores para as novas tecnologias. Os resultados apontam, considerando-se as condições ora adotadas, que das 62 distribuidoras avaliadas, em 25 não há viabilidade para a implantação das REI, ou seja, em 37 empresas percebe-se atratividade econômica. Ademais, constatou-se que os motivadores para essas redes no país são a redução de perdas não técnicas, o aumento da eficiência energética e a melhoria da qualidade do serviço. Com base nesses resultados, o trabalho oferece subsídios para elaboradores de políticas públicas em nível nacional e regional, para a agência reguladora e para as distribuidoras. / The implementation of Smart Grids has resulted in significant benefits in the electricity distribution sector of different countries. However, the associated investments are huge, which indicates the need for an assessment of their economic viability and, consequently, of their motivators. Some studies have already addressed this need at a national level. However, there is still no analysis in Brazil that incorporates the specific characteristics of the different distribution utilities. In this context, the present study aims to perform a cost-benefit analysis of Smart Grids implementation in the Brazilian electricity distribution companies. In order to accomplish this, the Present Value (PV) of 3 cost and 8 benefit categories is estimated and, through clustering processes and correlation techniques, the motivators for the new technologies are identified. The results indicate that, under the conditions adopted, in 37 out of the 62 assessed utilities, economic viability for the implementation of Smart Grids is already observed. In addition, it was verified that the motivators for intelligent networks in the country are non-technical losses reduction, energy efficiency increase and service quality improvement. Based on these results, the study offers subsidies for, public policy makers at regional and national level, for the regulatory agency and for the distribution utilities.
926

Projeto de plataforma de análise de conversão de tração de veículos com motor a combustão interna para tração elétrica / Development of a analysis platform to analyze the transformation of the traction of a vehicle with internal combustion engines to electric traction

Costa, Marcos de Oliveira 12 February 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2015. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2015-11-04T12:10:32Z No. of bitstreams: 1 2015_MarcosOliveiraCosta.pdf: 3231771 bytes, checksum: a5f8ae867c6961cdaba96ec3569d7131 (MD5) / Approved for entry into archive by Marília Freitas(marilia@bce.unb.br) on 2016-01-25T15:46:42Z (GMT) No. of bitstreams: 1 2015_MarcosOliveiraCosta.pdf: 3231771 bytes, checksum: a5f8ae867c6961cdaba96ec3569d7131 (MD5) / Made available in DSpace on 2016-01-25T15:46:42Z (GMT). No. of bitstreams: 1 2015_MarcosOliveiraCosta.pdf: 3231771 bytes, checksum: a5f8ae867c6961cdaba96ec3569d7131 (MD5) / Este trabalho demonstra o projeto e a execução da plataforma de análise de conversão de veículos, dotados originalmente com motores a combustão interna, para tração elétrica. A metodologia consistiu de uma revisão bibliográfica de aspectos teóricos pertinentes para embasar a conversão da tração de um veículo, seguida do projeto e da execução de uma bancada como fonte de energia elétrica e estrutura de controle para o motor elétrico. Posteriormente, um dinamômetro de rolos foi associado. Diversos equipamentos para quantificação e análise das grandezas torque, potência, rendimento e consumo, foram integrados à bancada e ao dinamômetro, compondo assim, uma plataforma de análise. Um veículo Fiat Palio, convertido com um motor elétrico trifásico de indução refrigerado a água foi analisado na plataforma através do ciclo da SAE J227a. Concluiu-se então, que a plataforma insere-se em um ambiente altamente propício, pois permite avaliar, sob diversos aspectos, os veículos elétricos convertidos. Essa funcionalidade terá papel fundamental na formação de estudantes de engenharia e no desenvolvimento de projetos acadêmicos para mobilidade elétrica. / This work demonstrates the design and implementation of vehicle conversion analysis platform, equipped originally with internal combustion engines to electric traction. The methodology consisted of a literature review of relevant theoretical aspects to support the conversion of traction of a vehicle, then the design and implementation of a bench as a source of power and control structure for the electric motor. Later, a dynamometer rollers was associated. Miscellaneous equipment for measurement and analysis of magnitudes torque, power, income and consumption, were integrated into the bench and dynamometer, making thus an analysis platform. A vehicle Fiat Palio, converted a three-phase electric induction motor cooled water was analyzed on the platform through the SAE J227a cycles. It was therefore concluded that the platform is inserted in a highly supportive environment because it allows evaluating, in many ways, the converted electric vehicles. This functionality will have a key role in training of engineering students and developing academic projects for electric mobility.
927

Instrumentação e controle em ciclismo assistido por estimulação elétrica para indivíduos com lesão medular

Fonseca, Lucas Oliveira da 14 December 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2015. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-03-15T19:58:44Z No. of bitstreams: 1 2015_LucasOliveiradaFonseca.pdf: 15747878 bytes, checksum: c40ee76515cdc4a54caf4264967bcbcf (MD5) / Approved for entry into archive by Marília Freitas(marilia@bce.unb.br) on 2016-05-04T13:08:53Z (GMT) No. of bitstreams: 1 2015_LucasOliveiradaFonseca.pdf: 15747878 bytes, checksum: c40ee76515cdc4a54caf4264967bcbcf (MD5) / Made available in DSpace on 2016-05-04T13:08:53Z (GMT). No. of bitstreams: 1 2015_LucasOliveiradaFonseca.pdf: 15747878 bytes, checksum: c40ee76515cdc4a54caf4264967bcbcf (MD5) / O sistema nervoso é responsável por grande parte das funções do corpo humano. Ele pode ser dividido em sistema nervoso central e sistema nervoso periférico. O sistema nervoso central compreende o encéfalo e a medula espinhal. Uma lesão na medula espinhal, seja ela traumática ou não, pode causar rompimento dos nervos e interrupção dos caminhos neurais. Se isso acontecer, todas as funções abaixo do nível da lesão serão parcial ou totalmente comprometidas. Uma das consequências mais evidentes de lesão medular é a perda da função motora. Uma lesão de nível torácica ou mais baixa torna a pessoa paraplégica, e uma lesão de nível cervical torna a pessoa tetraplégica. Além disso, essa condição pode acarretar incontinência urinária, perda de densidade óssea, disfunções sexuais e depressão. Além de fisioterapia tradicional, existem outras técnicas utilizadas na reabilitação. Entre elas, estimulação elétrica funcional possui a vantagem de potencializar a plasticidade do sistema nervoso ao estimular, simultaneamente, fibras nervosas aferentes e eferentes. Este trabalho estuda o uso dessa técnica para estimular membros inferiores de indivíduos para ciclismo em um contexto de reabilitação e esporte. São realizado testes com diferentes estratégias de controle e seus resultados são comparados entre si e com a literatura. Os resultados dos testes mostram que o controle em malha fechada com um controlador PI e uma segunda malha de controle que se adequa à cadência da pedalada proporciona um exercício que pode demorar mais de 5 minutos. Conclui-se que a estimulação elétrica, aliada à estratégias de controle em malha fechada, é uma tecnologia promissora para a reabilitação e prática de ciclismo em indivíduos com lesão medular. / The nervous system is responsible for many of the human body functions. It can be divided in central nervous system and peripheral nervous system. The central nervous system is the the brain and the spinal cord. A spinal cord injury, traumatic or not, can cause nerve’s ruptures and neural pathway’s disruptions. Were it to happen, all body functions below the injury level would be partially or completely compromised. One of the most apparent consequence is the loss of motor function. A thoracic or lower level injury will make the person paraplegic, and a cervical level injury will make the person quadriplegic. Furthermore, this condition can cause urinary incontinence, loss of bone density, sexual dysfunction and depression. Besides traditional physiotherapy, there are other techniques used in rehabilitation. Among them, functional electrical stimulation has the advantage of induce the nervous system’s plasticity as it stimulates, at the same time, efferent and afferent neural fibers. This work investigates this technique to stimulate individual’s lower limbs for cycling in the context of rehabilitation and sport. Test with different control strategies are performed and the results are compared to each other and to the literature. The test’s results show that closed loop control with a PI controller and a second loop that adapts to the cadence provides a longer than 5 minutes exercise session. It is concluded that electrical stimulation, along closed loop strategies, is a promising technology for rehabilitation and cycling for spinal cord injury individuals.
928

Análise comparativa entre as demonstrações contábeis societárias e regulatórias das distribuidoras de energia elétrica brasileiras : efeitos na estrutura de capital

Rocha, Leila Conceição Novais 01 February 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Economia, Administração e Contabilidade e Gestão de Políticas Públicas, Programa de Pós-Graduação em Ciências Contábeis, 2017. / Submitted by Raquel Viana (raquelviana@bce.unb.br) on 2018-06-22T17:43:54Z No. of bitstreams: 1 2017_LeilaConceiçãoNovaisRocha.pdf: 1484567 bytes, checksum: 83b33d7eaeb7e5c79829340691f2767d (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-06-29T16:39:26Z (GMT) No. of bitstreams: 1 2017_LeilaConceiçãoNovaisRocha.pdf: 1484567 bytes, checksum: 83b33d7eaeb7e5c79829340691f2767d (MD5) / Made available in DSpace on 2018-06-29T16:39:26Z (GMT). No. of bitstreams: 1 2017_LeilaConceiçãoNovaisRocha.pdf: 1484567 bytes, checksum: 83b33d7eaeb7e5c79829340691f2767d (MD5) Previous issue date: 2018-06-22 / O célebre artigo de Modigliani e Miller (1958) encadeou as discussões sobre política de financiamento das empresas. Naquele estudo seminal, os autores, com base nos pressupostos dos mercados de capitais perfeitos, concluíram pela irrelevância da estrutura de capital como fator de valorização das empresas. A partir de então, duas correntes teóricas dominam esse debate – teoria do Trade Off, que considera a existência de uma estrutura ótima de capital, e a Teoria do Pecking Order, que sugere a existência de uma hierarquia no uso das fontes de financiamento. Da quantidade de pesquisas que examinaram as escolhas financeiras das empresas, percebe-se que essas discussões se estendem a todos os segmentos da economia, e com o setor elétrico não poderia ser diferente. Diante disso, este estudo tem por objetivo analisar as estruturas de capital das distribuidoras de energia elétrica do Brasil. Entretanto, há uma singularidade a ser observada nessas empresas, a estrutura de capital das distribuidoras pode ser analisada sob dois resultados contábeis – o resultado societário e o resultado regulatório, e é sobre essas diferenças de práticas contábeis que esse estudo se assenta. Para tanto, a pesquisa coletou dados anuais das 61 concessionárias brasileiras de energia elétricas, no período de 2011 a 2015, e empregou um modelo adaptado de Fama e French (2002), a fim de investigar a significância dessas divergências na estrutura de capital dessas concessionárias. Os resultados demonstram que a diferença entre as médias encontradas para as estruturas de capital sob o enfoque societário e regulatório são estatisticamente significantes. Na sequência a pesquisou identificou que, na média, o percentual de endividamento das distribuidoras, tanto societário, quanto regulatório, está acima do percentual sugerido pelo regulador. Os resultados também permitem afirmar que há diferença nos determinantes de capital quando da comparação entre as duas contabilidades, e que no cenário regulatório as variáveis: lucratividade, rentabilidade, tamanho da empresa e investimento apresentaram significância estatística, e em linha de proposta com a teoria Pecking Order. A pesquisa concluiu ainda que, os resultados regulatórios refletem de maneira mais satisfatória a estrutura de capital das distribuidoras de energia elétrica do Brasil. Esse trabalho contribui para a discussão a respeito dos determinantes das estruturas de capital e os efeitos das diferenças de práticas contábeis societárias e regulatórias no setor elétrico brasileiro. / The renowned study by Modigliani and Miller (1958) ignited the discussions on the coporate finance policy. In that seminal study, the authors, based on the assumptions of the perfect capital markets, concluded that the value of a firm is unaffected by the capital structure. From then onwards, two theoretical approaches dominate the debate – Trade-Off Theory, which endorses the existence of an optimal capital structure, and the Pecking Order Theory, which establishes a hierarchy in the use of financing sources. From several researches that explored the financial choices of the companies, it can be seen that these discussions extend to all sector of economy, including the electrical sector. This study aims to analyze the capital structures of Brazilian electricity distributors. However, there is a singularity to be noticed in those companies, the capital structure of the distributors can be assessed under two accounting systems - the corporate accounting system and the regulatory accounting system. This paper is based on the differences of those accounting practices. The research collected annual data of 61 Brazilian electricity distributors between 2011 and 2015. It used a model adapted from Fama and French (2002), in order to investigate the significance of these divergences in the capital structure of these companies. The results show that the difference between the averages found for capital structures under the corporate and regulatory approaches are statistically significant. Then, the survey found that the electricity distributors´ percentage of indebtedness, using both corporate and regulatory accounting systems, is above the percentage suggested by the regulator. The results imply that there are different capital determinants that depends on the accounting systems. Another conclusion is that in the regulatory accounting system, the variables profitability, company size and investment have statistical significance and in accordance to the Pecking Order Theory. The study also concluded that the regulatory accounting system expresses, in a more satisfactory way, the capital structure of Brazilian electricity distributors. This paper contributes to the discussion about the determinants of capital structures and the effects of differences on corporate and regulatory accounting systems practices in Brazilian electricity sector.
929

Influência da corrente capacitiva de linhas de transmissão no desempenho da função de proteção de distância

Silva, Suellen Paula de Oliveira 13 April 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2018. / Submitted by Fabiana Santos (fabianacamargo@bce.unb.br) on 2018-08-28T18:05:26Z No. of bitstreams: 1 2018_SuellenPauladeOliveiraSilva.pdf: 4269013 bytes, checksum: 52b77fa5ead03964d6ede229146eb8b8 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-08-31T19:42:15Z (GMT) No. of bitstreams: 1 2018_SuellenPauladeOliveiraSilva.pdf: 4269013 bytes, checksum: 52b77fa5ead03964d6ede229146eb8b8 (MD5) / Made available in DSpace on 2018-08-31T19:42:15Z (GMT). No. of bitstreams: 1 2018_SuellenPauladeOliveiraSilva.pdf: 4269013 bytes, checksum: 52b77fa5ead03964d6ede229146eb8b8 (MD5) Previous issue date: 2018-08-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES). / Esta dissertação apresenta a avaliação do desempenho de estratégias de mitigação do efeito da corrente capacitiva de linhas de transmissão no desempenho da proteção de distância. Para tanto, foram avaliados dois algoritmos propostos na literatura sobre o assunto. O primeiro é baseado no modelo de linha longa, também denominado de modelo π equivalente ou π exato, enquanto o segundo baseia-se em capacitâncias concentradas nos terminais da linha (modelo π nominal). Seus desempenhos foram comparados com o da tradicional formulação de proteção de distância. O Programa de Alternative Transients Program (ATP) foi utilizado para modelar uma linha de transmissão de 60 Hz / 500 kV de 200 km de comprimento, em que foram simuladas uma grande variedade de faltas. Os desempenhos dos algoritmos são avaliados utilizando a análise de sensibilidade paramétrica, na qual apenas parâmetro muda o valor a cada vez, proporcionando uma compreensão mais ampla da relação entre cada parâmetro e o desempenho dos algoritmos. Para fazer isso, a análise foi realizada usando a resposta dos algoritmos durante o regime permanente de curto-circuito. Os resultados obtidos revelam que as estratégias alternativas não levam a melhorias significativas para o cenário avaliado neste trabalho, de modo que a formulação tradicional ainda é a solução mais simples e robusta para a proteção de distância de linhas de transmissão. / This master thesis presents the performance evaluation of alternative strategies to mitigate the capacitive current effect of transmission lines on distance protection. In order to do so, two algorithms reported in the literature on the subject were evaluated. The first one is based on the π -equivalent line model, whereas the second one uses lumped capacitance (πnominal model). Their performances have been compared with the one of traditional distance protection formulation. The Alternative Transients Program (ATP) was used to model a 60 Hz/500 kV transmission line 200 km long, in which a wide variety of faults were simulated. The performances of the algorithms are evaluated by using parametric sensitivity analysis, thereby only one parameter value changes at a time, providing a more comprehensive understanding of the relationship between each parameter and the performance of the algorithms. In order to do so, the analysis was carried out using the response of the algorithms during the fault steady-state regime. The obtained results reveal that the alternative strategies do not lead to significant improvements for the scenario evaluated in this work, such that the traditional formulation is still the simpler and more robust solution to distance protection of transmission lines.
930

Avaliação da utilização do modo standby em eletrodomésticos e de propostas de soluções mitigadoras para redução do seu consumo energético

Rodrigues, Jean Ronir Ferraz 27 April 2010 (has links)
No description available.

Page generated in 0.0984 seconds