11 |
Elektros įrenginių patikimumo ir nelaimingų atsitikimų priežastinio ryšio tyrimai / Research of causality between reability of elektric devices accidents with themBudzevičius, Gediminas 14 June 2004 (has links)
Reability of electric device is examined in diploma work engineer’s degree. It is written about classification in reability, in incorruptibility rate. It is researched in accidents, causability of accidents in Lithuania. One question – what should we do to make less accidents. One of solution is to use safety and reability electric devices. Data of accident in Lithuania is used, which happened till the 5th of may 2003 year. Conclusion and recommendation – do not economize to safety and reability electrical device.
|
12 |
Elektros įrenginių saugos parametrų tyrimas / The investigation of security parameters of electrical equipmentKneižys, Nerijus 20 June 2006 (has links)
In the present study, there was performed a research of safety parameters of electrical devices, there were performed various measurements and calculations, comparisons of received results, considered problems, associated with these parameters. There was considered condition of equipment before and after repairs.. Proposed suggestions regarding installation of unconventional devices as well as calculating during the process of design, there was described a research of dependence of resistances of grounders on deepening in earth, performing measurements. Also, upon selection of calculation methodology, there were performed calculations of grounded resistances. The results of calculations were compared with the measured ones.
There was touched on a subject of solution of some problems of grounder installation - i.e. installation of unconventional grounder. There was provided the method of installation of such grounder, peculiarities of its equipment. There were analysed results of measurement of screws, they were compared with the results of conventional grounders. There was developed the methodology of calculations of grounders and there was provided data of calculations as well as comparison with the measured ones. There was described application of this method as well as its benefit and advantages.
There were considered peculiarities of results of measurement of resistances of transitive contacts, positioned in chemically aggressive environment. There was analysed the... [to full text]
|
13 |
Elektros energijos naudojimo tyrimas medienos apdirbimo pramonėje / The reasearch of electricity energy consume at wood processing industryIgnatavičius, Edgaras 29 September 2008 (has links)
Didžiulės elektros energijos vartojimo sąnaudos karkasinių namų gamyboje ganėtinai ženkliai didina gamybos savikainos kaštus, kas tiesiogiai atsiliepia įmonės pelnui. Medienos apdorojimo pramonės produkcijos galima pagaminti gerokai daugiau (arba pagaminant tą patį kiekį suvartoti mažiau elektros energijos), ne vien tik kuriant naujus didesnio našumo medienos apdirbimo įrenginius, bet ir racionaliai naudojant esamus, bei nuolat juos modernizuojant. Šiame darbe tiriamas karkasinius namus gaminančios ir statančios įmonės UAB „Namų statyba“ elektros energijos suvartojimas. Buvo siekiama nustatyti elektros energijos taupymo galimybes, iš įmonės elektros energijos suvartojimo pereiti prie energijos sunaudojimo normos vienam karkasiniam namui pagaminti. Atlikus tyrimą nustatyta, kurioje medienos apdirbimo operacijoje galima būtų sumažinti elektros energijos suvartojimą. Taip pat pateikiami pagrįsti elektros energijos efektyvumo didinimo būdai. / Engineering prime costs increase because of a great consumption input of electricity energy at framework house manufacture, which directly influence company profit. It is possible to produce much more wood processing industry output (or to consume less electricity energy while producing the same quantity), not only by creating new mechanisms of greater wood processing productivity, but also by racionally using the present ones and constantly modernizing them. The consume of electricity energy of the JSC „Namų statyba“ which specializes at manufacturing and building framework houses is being researched at this work. The target was to estimate the saving potencial of electricity energy and to come from company electricity energy consume to the norm of electricity energy that is necessary to build a single framework house. Wood processing operation at which it is possible to reduce electricity energy consumtion was estimated after the research. The reasoned methods how to increase the effectiveness of electricity energy are presented as well.
|
14 |
Asinchroninio variklio ir dažnio keitiklio pavaros energetinių rodiklių tyrimas / The research on power paremeters of variable speed AC driveAstrauskas, Tomas 17 June 2005 (has links)
The theme of Master project of Energetics engineer is to analyze the power paremeters of noncontrollable speed AC drive. Is to analyze the power paremeters of variable speed AC drive. Is to accomplish the power paremeters of variable and noncontrollable speed AC drive. Describe the results of investigate and render the respective findigs.
|
15 |
Atsinaujinančių elektros energijos išteklių efetyvumo ir poveikio aplinkai palyginimas / Comparison of renewable electric energy resource efficiency and environmental impactPaužaitė, Giedrė 14 June 2010 (has links)
Darbe analizuojami atsinaujinančios elektros energijos ištekliai, pasirinkti remiantis atsinaujinančių išteklių energetikos įstatyme plačiausiai analizuojamais ir didžiausias perspektyvas turinčiais energijos ištekliais Lietuvoje. Išskirti trys pagrindiniai atsinaujinančios energetikos šaltiniai: vėjo energetika, biomasės deginimo metu gaunama elektros energija, bei hidroenergetika, pastarąją skirstome į didžiąsias hidroelektrines ir mažąsias hidroelektrines. Naujuoju atsinaujinančių išteklių energetikos įstatymu tikimasi elektros energijos dalį bendrajame šalies elektros energijos sunaudojime (pagamintos iš atsinaujinančių energijos išteklių), padidinti iki 20 procentų, kas reikštų sparčias AEI elektrinių statybas. Investicijų į atsinaujinančią energiją, taupų jos naudojimą ir naujas technologijas stiprinimas prisideda prie darnaus vystymosi ir padeda kurti naujas darbo vietas, skatinti ekonomikos augimą, stiprinti konkurencingumą ir plėtrą, kad Lietuva galėtų žengti į saugesnę, švaresnę ir konkurencingesnę ateitį. Todėl aplinkosauginiu požiūriu svarbu palyginti AEI elektrinių efektyvumo rodiklius bei atlikti poveikio aplinkai vertinimą, palyginant jų poveikį aplinkos komponentams. / This work analyzes the use of renewable energy resources (wind, hydro and biomass burning) and the effectiveness of their environmental impact. From the pending renewable energy sources in Lithuania we have the highest prospects for wind energy, especially offshore, and biomass burning. Hydropower development opportunities in Lithuania, the typical plains region, where the energy potential of rivers is small and flooding areas causes’ significant ecological damage, prospects are limited. Renewable energy resources impact to the environment is very different. The biggest environmental impacts of hydropower, the smallest - biomass burning derived electricity.
|
16 |
Skirstomojo elektros tinklo informacinės sistemos apimties ir struktūros tyrimas / The research on extent and structure of information system of Distributing electricity networkŠlikas, Ričardas 13 June 2005 (has links)
The theme of Master project of Energetics engineer is to analyze the information equipment. Is to analyze the utilitarian systems limitation at present. Describe the rising problems and benefit of successful solutions. Is to analyze extent and structure of distributing electricity network information system , to find the ways of why improve receiving of required information. Present the draft and vision of the information system. Present the attitudes to making information system, constitutional culture and ways to get information system. Describe the goals of information system and the characteristic of results.
|
17 |
Daugiafunkcinių dvikoordinačių vykdymo sistemų valdymas / Control of multifunctional two-coordinate drive systemsBlažiūnas, Giedrius 19 July 2005 (has links)
The research object is to develop and investigate methods and algorithms for fmleexthiboldes ,c othnetr oplr oobfl etmwso -ocfo osradviinnagt ea nddri vrea tisoynsatel mhas.n dAlipnpgl inogf edneevreglyo,p eeqdu cipomnternotl and global material resources have to be investigated in cases of two dimensional positioning and scanning processes under circumstances omaximal.
|
18 |
Aktyviosios ir reaktyviosios galių režimų valdymas restruktūrizuotoje elektros energetikos sistemoje / Active and reactive power control in restructured electrical energy systemŠulga, Dalius 25 July 2005 (has links)
The main objective of the Thesis is to work out the methodology aimed to develop a closely integrated electricity network model to be used for real time calculations, and afterwards, based on this methodology, to develop a model of a closely integrated electricity network, which would be applicable in real time calculations of active and reactive power.
|
19 |
ELEKTROS KOKYBĖS IR DARBO SĄLYGŲ PRAMONĖS ĮMONĖJE TYRIMAS / The electric energy is the main rate influencing the activity of the companyAnglickas, Kęstutis 29 September 2008 (has links)
Naujas LST EN 50160 standartas skatina vartotojus domėtis elektros energijos kokybe. Įtampos charakteristikų matavimai buvo atliekami mažos galios įmonės tinkluose: įmonės gamybos bare ir automatizuotoje garo gamybos katilinėje. Šiuose objektuose gausu naujos valdymo įrangos, daugiau kaip 30% galingumo sudaro netiesinės apkrovos, sukeltos puslaidininkinių prietaisų. Matavimai buvo atliekami su energijos kokybei skirtu matuoti prietaisu MEMOBOX. Buvo išmatuotos sekančios elektros energijos kokybės charakteristikos: dažnis, įtampos kitimo vertės, įtampos mirgėjimo aštrumas, tiekiamos įtampos pertrūkiai, viršįtampiai, nesimetrija, harmoninės įtampos.
Atlikti matavimai rodo, kad standarto LST EN 50160 įtampos charakteristikų nustatytos vertės yra realios, ir dėl jų nesilaikymo dažniausiai kaltas pats vartotojas. Viršytos mirgėjimo aštrumo vertės yra sukeliamos pačių vartotojų. Harmoninių įtampų vertės mažos galios vartotojų tinkluose yra pakankamai aukštos. Vyraujančios harmonikos - 3, 5, 7 ir 9 eilės. Harmoninių įtampų matavimai įmonės gamybos bare įrodė duomenys rodo, kad įmonėje netiesinių iškreipių faktorius NIF nesiekia 2% , nežiūrint į aukštą netiesinių apkrovų lygį. Matavimai garo katilinėje parodė, kad ne visada netiesinių iškreipių faktorius NIF gali parodyti tikrąjį netiesinių iškraipymų lygį, todėl vykdant svarbius matavimus reikia peržiūrėti visas harmoninių dedamųjų vertes ir įsitikinti ar jos neviršija leistino lygio. Ekonominiai skaičiavimai rodo, kad aukštas... [toliau žr. visą tekstą] / The theme of master work is actual because quality of electric energy is the main rate influencing the activity of the company and the quality of its work conditions. Standard LST EN 50160 at this moment is the essential document which describes the main characteristics of voltage and to keep to them electric energy could be called qualitative. Voltage characteristics were measured at the company in the system of low voltage using the device which helps to fix the main electric energy characteristics that is frequency, size of voltage, blinking, downfalls, intermissions, dissymmetric, harmonic voltage. Done measurements show that there are enlarged harmonic levels, especially of the third, fifth, seventh and eleventh harmonics. It is recommendable in the system of the company to perform periodically electric energy quality tests. The survey shows, that high THD worsens the activity of the company, increases losses of the energy, exacerbates work conditions in the company. On purpose to avoid increased levels of harmonics it is recommended to mount filters of harmonics.
|
20 |
Elektros energijos apskaitos priemonių tikslumo tyrimas / Investigation on the accuracy of electricity metersPimanov, Vadim 21 June 2013 (has links)
Tyrime buvo ištirta elektroninio ir indukcinio elektros energijos skaitiklių paklaidų priklausomybė nuo apkrovos stiprio, galios koeficiento ir tinklo įtampos. Tyrimui atlikti buvo naudojamas elektros energijos skaitiklių analizatorius CALPORT 100, kurio tikslumo klasė 0,2. Nustatyta, kad padidėjus tinklo įtampai 10-čia voltų elektroninio elektros energijos skaitiklio paklaida padidėja apie 0,1 %, o indukcinio sumažėja apie 0,065 %. Didžiausi paklaidų pokyčiai abiejų tipų skaitikliuose pastebėti palaikant mažiausias nuo 0,25 A iki 3 A apkrovas. Apkrovos galios koeficiento sumažėjimas nuo 1,0 iki 0,7, esant standartiniai 230 V tinklo įtampai, sukėlė ženklų abiejų tipų skaitiklių neigiamų paklaidų padidėjimą iki -3,48 % elektroniniam skaitikliui ir -3,85 % indukciniam skaitikliui. Didžiausios paklaidos buvo užfiksuotos esant didžiausiai tinklo įtampai 260 V ir mažiausiai galios koeficiento reikšmei 0,7, tuo metu elektroninio skaitiklio santykinė paklaida siekė -4,55 %, o indukcinio -5,32 %. / The aim of this study - to investigate the relation between accuracy of electrical meters and voltage, load and power factor variations. Experiments were performed with electronic and induction type electrometers. Examinations were carried out with electricity meter analyzer CALPORT100. It was found that the increase in voltage of 10 volts here an electricity meter error increases to about 0.1%, while induction by about 0,065%. The largest variations in the two types of meters observed in maintaining the minimum from 0.25 A to 3 A loads. The load power factor decreased from 1.0 to 0.7, with standard 230 V mains voltage, confounding both counters negative bias increases to -3.48% for the electronic meter and meter induction -3,85%. Maximum error was recorded at the maximum voltage of 260 V and a minimum power factor 0.7, while the electronic meter relative error was -4.55% and -5.32% induction.
|
Page generated in 0.0778 seconds