• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1048
  • 28
  • 27
  • 27
  • 23
  • 17
  • 12
  • 12
  • 9
  • 9
  • 7
  • 7
  • 5
  • 1
  • 1
  • Tagged with
  • 1089
  • 599
  • 180
  • 148
  • 111
  • 110
  • 109
  • 108
  • 107
  • 104
  • 100
  • 99
  • 89
  • 86
  • 81
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Estudo eletromiografico pre e pos utilização de placa oclusal compressivel de silicone em bruxistas e não bruxistas

Salles, Rubens Frota de Moraes 27 February 2003 (has links)
Orientador: Fausto Berzin / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T15:17:46Z (GMT). No. of bitstreams: 1 Salles_RubensFrotadeMoraes_M.pdf: 3512870 bytes, checksum: c0653e801ef874060f9114d12d350107 (MD5) Previous issue date: 2003 / Resumo: O propósito desta pesquisa foi avaliar os achados eletromiográficos dos músculos temporal - feixe anterior, e masseter, bilaterais, de pacientes com hábito de bruxismo, antes e após o uso de placas compressíveis de silicone de 3mm de espessura. Foram avaliados dois grupos de voluntários, sendo um grupo de bruxistas (experimental) composto de dez indivíduos, todos do sexo feminino, com idade média de 22,25 anos (DP = 1,96), e outro grupo de não bruxistas (controle), composto de dez indivíduos, também todos do sexo feminino, com idade média de 22,0 anos (DP = 1,72). Todos os integrantes dos dois grupos fizeram uso da placa oclusal, além de que, todos os indivíduos realizaram exame eletromiográfico, pré e pós-tratamento. Os exames eletromiográficos foram realizados em todos os voluntários por meio de um sistema de aquisição de sinais, com eletrodos diferenciais ativos de prata pura de superfície. Para a análise dos dados utilizou-se o teste t para dados pareados (para comparar a amplitude nos diferentes músculos e nos diferentes tempos) e o teste de intervalo de confiança das diferenças entre os grupos dos bruxistas e dos não bruxistas. Os resultados mostraram que há uma diminuição na atividade elétrica no grupo dos bruxistas pós-tratamento realizado através do uso da placa compressível de silicone de 3mm de espessura. Portanto, a partir dos resultados concluiu-se que se a placa compressível de silicone promoveu uma significativa diminuição da amplitude do sinal eletromiográfico nos músculos mastigatórios após seu uso, evidenciou-se desta maneira uma significativa redução da hiperfunção muscular destes músculos dos indivíduos bruxistas, mostrando desta maneira o seu efeito benéfico / Abstract: The objective of this research was to evaluate the electromyographic findings of the bilateral anterior temporal and masseter muscle activity of patients who had the habit of bruxism, before and after the use of 3mm compressed silicone splints. Two groups of volunteers were evaluated: one, the experimental group, consisting of ten people who suffered from bruxism, ali of them female, with an average age of 22.25 years (SD=1.96); the other, the control group, also consisting of ten females, with an average age of 22.0 years (SD=1.72). All of the participants, in both groups, made use of the occlusal splint and ali of them underwent electromyographic examinations, before and after the treament. Electromyographic examinations were performed in ali the volunteers through a signal acquisition system, with active differential electrodes with apure silver surface. For the analysis of the data the following tests were used: t test for paired data, to compare the amplitude of the different muscles at different times, and test of confidence intervals for the differences between the two groups (bruxists and non-bruxists). The results showed that there was a reduction in the electrical activity in the bruxist group after the treatment made with the 3mm compressed silicone splint. Therefore, on the basis of these findings, the conclusion was drawn that the compressed silicone splint produced a significant reduction in the amplitude of the electromyographic signal of the masticatory muscles, causing a significant reduction of muscular hyperfunction in these muscles for the bruxist subjects, fact that shows its beneficial effect / Mestrado / Anatomia / Mestre em Biologia Buco-Dental
162

Estudo eletromiografico dos musculos orbicularis da boca, segmentos superior e inferior (região medial), em jovens com maloclusão classe I de Angle

Zilli, Angela Sorgi 19 July 2018 (has links)
Orientador: Mathias Vitti / Dissertação (mestrado) - Universidade Estadual de campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-19T15:52:26Z (GMT). No. of bitstreams: 1 Zilli_AngelaSorgi_M.pdf: 2308425 bytes, checksum: 0ee580ad4a948806c2229910ee76837b (MD5) Previous issue date: 1994 / Resumo: A atividade dos músculos orbiculares superior e inferior da boca (região medial), foi estudada eletromiograficamente em jovens portadores de maloclusão Classe I de Angle, durante uma série de movimentos lábio-mandibulares. Utilizou-se eletrodos de superfície, onde os potenciais elétricos foram registrados em um eletromiógrafo TECA, modelo TE-4 de duplo canal e em outro eletromiógrafo NICOLET VIKING II de oito canais. Os resultados mostraram que: 1) existe diferença no funcionamento dos músculos orbiculares superior e inferior da boca entre indivíduos com maloclusão Classe I e aqueles com oclusão clinicamente normal; 2) os indivíduos com maloclusão Classe I apresentaram contração mais acentuada do músculo orbicular inferior em relação ao superior; 3) os movimentos de abertura-máxima da boca e sorrir espontaneamente foram os que apresentaram diferença altamente significativa quando comparados à posição de repouso;4) os músculos orbiculares suçerior e inferior da boca funcionam independentemente durante os movimentos lábio-mandibulares / Abstract: The muscular activity of orbicularis oris muscles (middle region) was studied electromyographically in normal occlusion; 2- the activity of inferior oris muscle was more accentuated than the superior in Class I malocclusion; 3- maximum mouth opening and smile youngsters with Class I malocclusion during mandibular movements. Action potentials were recorded and analysed with a TECA electromyograph TE-4 and another NICOLET VIKING II, using a pair of Beckman electrodes fixed over each muscle in middle region. The results showed that: 1- there is a difference of activity of superior and inferior orbicularis oris muscles between youngsters with Class I malocclusion and those with orbicularis were the movements that showed a great difference in muscles' activity when compared with the rest position; 4- the orbicularis oris muscles work independently during several movements studied. / Mestrado / Ortodontia / Mestre em Odontologia
163

Biofeedback por eletromiografia no controle do bruxismo em vigília associado ou não à mialgia

MONTEIRO, Ubirakitan Maciel 28 July 2017 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-09-27T22:48:00Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Ubirakitan Maciel Monteiro.pdf: 1878037 bytes, checksum: 71988376aac180278650224f18a6e8c4 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-11-19T20:53:14Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Ubirakitan Maciel Monteiro.pdf: 1878037 bytes, checksum: 71988376aac180278650224f18a6e8c4 (MD5) / Made available in DSpace on 2018-11-19T20:53:14Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Ubirakitan Maciel Monteiro.pdf: 1878037 bytes, checksum: 71988376aac180278650224f18a6e8c4 (MD5) Previous issue date: 2017-07-28 / INTRODUÇÃO: O bruxismo em vigília é um comportamento parafuncional que pode levar à mialgia dos músculos mastigatórios. O Biofeedback por eletromiografia (EMG) é uma técnica com potencial para reduzir estes sintomas, porém ainda não se sabe se participantes com e sem mialgia apresentam evoluções diferentes durante este treinamento. O objetivo deste estudo foi avaliar a eficácia do Biofeedback por eletromiografia no controle do Bruxismo em vigília associado ou não à Mialgia. MATERIAIS E MÉTODOS: Vinte e dois pacientes com diagnóstico clínico de Bruxismo em vigília foram divididos em dois grupos de acordo com critérios clínicos: com mialgia (grupo experimental, n= 15) e sem mialgia (grupo controle, n=8). Os participantes foram submetidos a cinco sessões de Biofeedback no músculo temporal anterior, com vinte minutos de duração cada. A potência elétrica muscular média foi calculada em cada uma das sessões. Além disso, os participantes foram avaliados com a Escala Visual Analógica (EVA) para dor antes e depois deste tratamento. RESULTADOS: no primeiro dia o grupo experimental apresentou maior potência elétrica em repouso (p=0,002), e maior pontuação na EVA (p<0,0001), em relação ao grupo controle. Houve correlação positiva significante entre estas duas variáveis em todos os participantes no primeiro dia (p = 0,002; spearman r= 0.62). Ao final da intervenção, não houve diferença significativa entre os grupos na EVA (0,1499), bem como entre a potência muscular de repouso (p=0,9716). CONCLUSÕES: O Biofeedback por EMG é capaz de reduzir a tensão muscular de repouso e a dor em pessoas com Bruxismo em Vigília associada com mialgia a valores semelhantes aos de participantes sem mialgia. Este estudo também apresentou a primeira evidência de que a mialgia está relacionada com o aumento da tensão de repouso nesta população. / INTRODUCTION: Awake bruxism is a parafunctional behavior that can lead to myalgia in masticatory muscles. Electromyography (EMG) Biofeedback is a potential technique to reduce these symptoms, but it is not known yet if the treatment results differ in participants with and without myalgia MATERIALS AND METHODS: It was developed a new biofeedback system for this experiment. Twenty-two patients with clinical diagnosis of Awake Bruxism were divided into two groups according to clinical criteria: myalgia-related (experimental group, n = 15) and without myalgia (control group, n = 8). The participants were submitted to five sessions of Biofeedback in anterior temporalis muscle, with a duration of twenty minutes each. Resting muscle electric power was calculated during each session. In addition, they were evaluated with Visual Analogue Scale (EVA) for pain before and after this treatment. RESULTS: The experimental group presented higher electrical power at rest (p = 0.002), and higher VAS score (p <0.0001), in relation to the control group at the first day. There was a positive correlation between these two variables in all participants in the first day (p = 0.002, spearman r = 0.62). At the end of the intervention, there was no significant difference between the groups on VAS (0.1499) and resting muscle power (p = 0.9716). CONCLUSIONS: EMG Biofeedback can reduce resting muscle tension and pain in people with Awake bruxism associated with myalgia. This study also presents a preliminar evidence that muscle pain is related to increased resting tension in this population.
164

Análise de variáveis biomecânicas e do risco de quedas de indivíduos idosos submetidos a diferentes condições de marcha

Hallal, Camilla Zamfolini. January 2011 (has links)
Orientador: Mauro Gonçalves / Banca: Adalgiso Coscrato Cardozo / Banca: Marcelo Tavella Navega / Resumo: O objetivo deste estudo foi investigar a influência do medo de cair sobre a ativação muscular e a co-contração de músculos dos membros inferiores de idosas e jovens ativas durante a marcha. Participaram do estudo 17 jovens fisicamente ativas e 18 idosas ativas, com baixo risco de quedas. As voluntárias foram solicitadas a andar sobre a esteira em duas condições distintas: marcha normal e marcha com medo de cair. Os sinais eletromiográficos foram coletados durante todo o teste de marcha dos músculos reto femoral (RF), vasto medial (VM), vasto lateral (VL), bíceps femoral (BF), tibial anterior (TA), gastrocnêmio lateral (GL) e sóleo (SO). Para a análise dos dados eletromiográficos foram usados os 10 ciclos de marcha iniciais de cada condição de marcha e os valores de envelope linear para cada sujeito foram normalizados pela média dos valores da condição de marcha normal para cada músculo. Para a análise dos dados de ativação muscular, foi usado o teste de Wilcoxon e o teste de Mann-Whitney. Para a análise dos dados de co-contração, foi usado o teste T student e o teste T student para amostras independentes. Os músculos RF, VM, VL e TA apresentaram ativação muscular significativamente maior na condição de marcha com medo de cair em relação à condição de marcha normal para jovens e idosos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Not avalaible / Mestre
165

Análise da confiabilidade do posicionamento dos eletrodos na aquisição do sinal eletromiográfico dos músculos do antebraço na tarefa de preensão palmar / Reliability of the positioning of the electrodes in the acquisition of electromyography activity in forearm muscles in the hand grip task

Tamanini, Guilherme 29 April 2015 (has links)
O objetivo deste estudo foi de analisar a confiabilidade teste reteste do posicionamento dos eletrodos na aquisição do sinal eletromiográfico dos músculos do antebraço na tarefa de preensão palmar, por meio de dois posicionamentos. O primeiro posicionamento proposto por Cram; Durie e o segundo proposto por Mogk; Keir. Foram recrutados 30 voluntários sendo divididos em 2 grupos com 15 indivíduos cada. O primeiro grupo era formado por indivíduos saudáveis, isto é, que não apresentavam qualquer patologia, trauma ou dor no membro superior. Este grupo era composto por 13 mulheres e 2 homens com idade média de 23,4 anos, sendo 13 destros e 2 canhotos. O segundo grupo era formado por indivíduos que apresentavam algum trauma no antebraço, punho ou mão, recrutados no centro de reabilitação e no ambulatório de cirurgia do membro superior do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo. A amostra era composta por 13 homens e 2 mulheres com idade média de 34,6 anos, sendo 14 destros e 1 canhoto. Todos os participantes assinaram o Termo de Consentimento Livre e Esclarecido. O procedimento foi realizado em dois dias com diferença de 24h entre as avaliações. A avaliação consistia em realizar a tarefa de preensão palmar com o dinamômetro analógico da marca Jamar® , realizando a máxima contração voluntária pelo período de 10 segundos com repouso de 3 minutos entre cada preensão, sendo coletados o sinal eletromiográfico de sete canais dos músculos do antebraço volar e dorsal, segundo cada método. Foi analisada a confiabilidade pelo índice de ICC e o SEM (Standard Error of Measurement). Os resultados obtidos mostram excelente correlação entre os dois posicionamentos em ambos os grupos. Quando verificado o valor de ICC do grupo de saudáveis verificou valores acima de 0.75 em todos os canais, o que demonstrou uma alta correlação entre as medidas em ambos os posicionamentos, com pequeno SEM. No grupo pacientes foi observado que nos músculos FUC, FSD e ERC uma correlação moderada para o posicionamento Mogk; Keir e somente no músculo FRC apresentou correlação moderada no posicionamento Cram; Durie. Os gráficos de Bland e Altman mostraram alta concordância entre as medidas, visto que, em ambos os posicionamentos, os valores ficaram entre o intervalo de confiança de 95% e próximos da linha média. Como conclusão pode-se inferir que ambos os posicionamentos apresentaram alta confiabilidade e alta correlação quando avaliado por meio do teste e re-teste, podendo ser utilizados para medida eletromiográfica dos músculos do antebraço / The objective of this study was to analyze test retest reliability of the electrodes placement in the acquisition of electromyography forearm muscles during a isometric hand grip task, through two different methods. The first method was proposed by Cram; Durie and the second by Mogk; Keir. We recruited 30 volunteers divided into 2 groups with 15 subjects each. The first group consisted of healthy subjects, who did not show any pathology, trauma or pain in the upper extremity. This group consisted of 13 women and 2 men with a mean age of 23.4 years, and 13 right-handed and 2 left-handed. The second group consisted of individuals who had previous trauma on the forearm, wrist or hand. They were recruited from the rehabilitation center and upper limb surgery clinic of the Medical School of Ribeirão Preto Clinical Hospital. The sample consisted of 13 men and 2 women with a mean age of 34.6 years, 14 right-handed and left-handed one. All participants signed the consent form. The procedure was performed in two days with 24 hours difference between assessments. The evaluation was to carry by a isometric handgrip task with a analog dynamometer Jamar®, with maximum voluntary contraction for 10 seconds with 3 minutes of rest and analised by CCI and SEM (Standard Error of Measurement) . The results obtained have a high correlation between the two methods in both groups. Analyzing the ICC value of the healthy group value noted above 0.75 in all channels, demonstrating a excelent correlation between the measurements in both positions and low SEM. Checking in group patients realize that the FUC, FSD and ERC muscles has a moderate correlation for Mogk; Keir positioning and only on FRC showed moderate correlation in Cram; Durie electrode placement method. Analyzing Bland and Altman method a high concordance was found between the measures, since in both positions, the values were between the confidence interval of 95% and close to the midline. Through this we can infer that both positions have high reliability and high correlation when measured by the test and retest
166

Influência da idade e do gênero na atividade eletromiográfica do sistema estomatognático / The influence of age and Generon electromyographic activity of the stomatognathic system

Cecilio, Flávia Argentato 28 September 2010 (has links)
O sistema estomatognático constitui um conjunto de estruturas bucais, órgãos e tecidos, que desenvolvem funções comuns, interdependentes, tendo como característica fundamental para o desenvolvimento morfológico e funcional, principalmente o mastigatório, dois fatores importantes: o desenvolvimento craniofacial e muscular. Como todo sistema, tem características que lhe são próprias, mas está intimamente ligado à função de outros sistemas como o nervoso, o circulatório, o endócrino, e todos em geral, porque não constitui uma unidade separada do resto do organismo, mas se integra a ele. Vários são os estudos a respeito do crescimento do esqueleto facial, no entanto, pouco se conhece sobre o desenvolvimento do sistema muscular da cabeça, tendo em vista a dificuldade relacionada, principalmente, com métodos de estudo. Os músculos desenvolvem-se, morfológica e funcionalmente, de forma planejada e organizada, mas ainda existem muitas dúvidas e questionamentos de que maneira que isso ocorre particularmente durante o envelhecer do ser humano. Este trabalho busca indícios da interação muscular no desenvolvimento craniofacial com o passar dos anos e tem como objetivo analisar a atividade eletromiográfica dos músculos masseter e temporal de crianças, jovens, adultos e idosos, com intuito de traçar critérios e parâmetros que possam ser considerados normais no desenvolvimento muscular mastigatório em função da idade e do gênero. Os aspectos investigados objetivam facilitar diagnósticos e prognósticos, trazendo contribuições para a comprovação da qualidade e estabilidade dos tratamentos, assim como estabelecendo padrões de normalidade. / The stomatognathic system is a set of oral structures, organs and tissues that develop common functions, interdependent, and as a fundamental characteristic for the morphologic and functional development, especially the chewing, two important factors: the development and craniofacial muscle. Like any system, has features of its own, but is closely linked to the function of other systems like the nervous, circulatory, endocrine, and everyone in general because it is a separate unit from the rest of the body, but integrates the him. Several studies about the growth of the facial skeleton, however, little is known about the development of the muscular system of the head, in view of the difficulty associated mainly with methods of study. The muscles are developed, morphologically and functionally, in a planned and organized, but there are still many doubts and questions how that occur, particularly during the aging of the human being. This paper seeks evidence of muscle interaction in craniofacial development over the years and aims to analyze the electromyographic activity of masseter and temporal muscles of children, youth, adults and seniors, aiming to draw up criteria and parameters that can be considered normal in masticatory muscle development in relation to age and gender. The study focused aim to facilitate diagnostic and prognostic, bringing contributions to the quality and stability of treatments, as well as establishing patterns of normality.
167

Efeitos de exercícios do método pilates e do treinamento resistido sobre o equilíbrio de adultos jovens sedentários: um ensaio clínico randomizado controlado

MORAIS, Priscilla Alencar de Oliveira 29 September 2016 (has links)
Submitted by Alice Araujo (alice.caraujo@ufpe.br) on 2018-06-13T18:18:48Z No. of bitstreams: 1 DISSERTAÇÃO Priscilla Alencar de Oliveira Morais.pdf: 2523242 bytes, checksum: c7b298cd259a1098c9ac103594f6e4bc (MD5) / Made available in DSpace on 2018-06-13T18:18:48Z (GMT). No. of bitstreams: 1 DISSERTAÇÃO Priscilla Alencar de Oliveira Morais.pdf: 2523242 bytes, checksum: c7b298cd259a1098c9ac103594f6e4bc (MD5) Previous issue date: 2016-09-29 / CAPES / O equilíbrio postural é essencial para as atividades funcionais e, para a sua manutenção, requer a organização de diversas estratégias do controle motor, as quais podem estar prejudicadas em indivíduos com comportamento sedentário. Alguns métodos de exercícios, como o Pilates e o treinamento resistido, prometem melhorar o equilíbrio a partir do fortalecimento muscular, porém seus efeitos necessitam ser quantificados e melhor compreendidos. Objetivo: Avaliar o efeito de protocolos de exercícios do método Pilates e de treinamento de força no equilíbrio estático de adultos jovens sedentários. Métodos: Estudo piloto controlado e randomizado envolvendo 12 adultos de 18 a 30 anos, sedentários, com peso normal, saudáveis e sem experiência com exercícios do método Pilates. Os voluntários foram triados e realizaram um teste de equilíbrio estático, tanto com os olhos abertos como com os olhos fechados, utilizando um equipamento com dois acelerômetros triaxiais e dois sensores de eletromiografia de superfície (EMG) cujos sinais foram sincronizados com uma captura de vídeo. O acelerômetro 1 foi acoplado sobre o esterno e o acelerômetro 2 sobre a quinta vértebra lombar. Os sensores de EMG foram posicionados sobre os músculos transverso do abdome/oblíquo interno e multífidos/paravertebrais. Após a avaliação os voluntários foram randomizados em um grupo experimental (GE) e um controle (GC), cada um contendo 6 voluntários. Os grupos foram submetidos a um treinamento de 6 semanas, com sessões de 1h de duração duas vezes por semana. O GE utilizou exercícios do método Pilates no solo e o GC utilizou exercícios de fortalecimento com pesos livres. Todos os voluntários foram reavaliados após as 6 semanas. Os dados adquiridos com os acelerômetros foram tratados para o cálculo da área da elipse de predição de 95% contendo os pontos do deslocamento dos sensores. Os valores de EMG obtidos durante as posturas foram normalizados em forma de percentual do maior valor obtido com a contração isométrica voluntária máxima. Os dados obtidos foram comparados com os testes de Mann-Whitney e Wilcoxon. Foi utilizado um nível de significância de 0,05 para todos os testes. Resultados: Não foram encontradas diferenças estatisticamente significativas na comparação intragrupos das variáveis analisadas. Houve uma redução média na área de deslocamento do acelerômetro 1 de 2,54±1,3cm2 para o GE e 1,0±0,8cm2 para o GC nos testes com os olhos abertos, e de 8,0±8,7cm2 para o GE e 9,0±7,5cm2 para o GC nos testes com os olhos fechados. Na avaliação com o acelerômetro 2, a redução média foi de 5,7±4,1cm2 para o GE e 9,7±9,2cm2 para o GC nos testes com os olhos abertos, e de 9,6±7,2cm2 para o GE e 9,9±5,6cm2 para o GC nos testes com os olhos fechados. A atividade dos músculos abdominais reduziu uma média de 0,7±0,5% no GE e aumentou 1,5±0,2% no GC. Conclusão: Tanto o Pilates como o treinamento de força promovem melhora no equilíbrio estático com redução da oscilação do centro de massa corporal, porém com o método Pilates a ativação da musculatura abdominal reduz sutilmente, o que pode ser em decorrência do uso de outros músculos sinergistas na tarefa de estabilização. / Postural balance is essential for functional activities and its maintenance requires the organization of various motor control strategies, which may be impaired in subjects with sedentary behavior. Some methods of exercises like Pilates and resistance training, promise to improve balance from muscle strengthening, but their effects need to be quantified and better understood. Purpose: To verify the effect of exercise protocols of the Pilates method and of resistance training on the static balance of sedentary young adults. Methods: Randomized controlled pilot study, involving12 adults aged between 18 and 30 years, sedentary, normal weight, without conditions and without experience with Pilates exercises. The volunteers performed a static balance test, with both eyes open and eyes closed, wearing an equipment with two triaxial accelerometers and two surface electromyography sensors (EMG) whose signals were synchronized with a video capture. The accelerometer 1 was coupled on the sternum and the accelerometer 2 on the fifth lumbar vertebra. The EMG sensors were positioned on the muscles transversus abdominis/internal oblique and multifidus/paraspinal. After the baseline assessment, the volunteers were randomized into an experimental group (EG) and a control group (CG), each containing 6 volunteers. The groups were submitted to a 6-week training with 1hr duration twice a week. EG performed Pilates exercises on the floor and CG performed strengthening exercises with free weights. All volunteers were reassessed after 6 weeks. The data acquired by the accelerometers were treated and the area of the 95% prediction ellipse containing the sensor displacement points was calculated. The EMG values obtained during the postures were normalized as a percentage of the highest value obtained with the maximal voluntary isometric contraction. Data were comparedusing Mann-Whitney and Wilcoxon tests.A 0.05 significance level was used for all tests. Results: No statistically significant differences were found in the betweengroup comparison of the variables analyzed. There was a mean reduction in the area of displacement of the accelerometer 1 of 2.54 ± 1.3 cm2 for the EG and 1.0 ± 0.8 cm2 for the CG in the tests with eyes open, and of 8.0 ± 8.7 cm2 for the EG and 9.0 ± 7.5 cm2 for the CG in the tests with eyes closed. In the evaluation with accelerometer 2, the mean reduction was 5.7 ± 4.1 cm2 for the EG and 9.7 ± 9.2 cm2 for the CG in the tests with eyes open, and 9.6 ± 7.2 cm2 for the the EG and 9.9 ± 5.6 cm2 for the CG in the tests with eyes closed. The activity of the abdominal muscles reduced an average of 0.7 ± 0.5% in the EG and increased 1.5 ± 0.2 % in the CG. Conclusion: Both Pilates and strength training promote improvement in static balance with reduction of body mass center oscillation, but with the Pilates method exercises, the activation of the abdominal muscles reduces subtly, which may be due to the use of other synergistic muscles in the stabilization task.
168

Confiabilidade dos valores de amplitude da eletromiografia de superfície durante exercícios para membro superior com carga axial e superfície estável e instável / Reliability of surface electromyography amplitude values during exercises for the upper limb with axial load and stable and unstable surfaces

Araujo, Rodrigo Cappato de 28 July 2006 (has links)
O objetivo deste estudo foi avaliar a confiabilidade intradia e interdias dos valores de amplitude da eletromiografia de superfície, dos músculos da cintura escapular e membro superior, durante a realização de 3 exercícios isométrico com a extremidade distal do segmento fixa em uma superfície estável e outra superfície instável, com descarga de peso axial controlada para o membro superior. Para tanto, 20 adultos saudáveis realizaram os exercícios push-up, bench-press e wall-press em diferentes níveis de carga (80 e 100% da carga máxima). Os valores de carga produzida por cada um dos exercícios foram registrados de maneira simultânea à eletromiografia. Os sujeitos realizaram três contrações voluntárias máximas (CVM) na posição de prova de função muscular de cada músculo, para obtenção do valor de referência para normalização dos valores de root mean square (RMS) e da integral do envoltório linear (?env). Os sujeitos foram instruídos, a realizarem de forma aleatória, 3 séries de contrações isométricas por 6 segundos em cada exercício, com intervalo de 2 minutos entre as séries e exercícios.Os sinais eletromiográficos dos músculos deltóide porção anterior e posterior, trapézio fibras superiores, serrátil anterior, peitoral maior porção clavicular, bíceps braquial porção longa e tríceps braquial porção longa foram captados por eletrodos de superfície ativos simples diferenciais, realizados em dois testes com intervalo de sete dias. Os dados foram coletados com freqüência de amostragem de 4000Hz e aplicados filtros digitais de passa baixa de 500Hz e passa alta de 20Hz. Os valores de RMS e ?env foram normalizados pelo valor máximo da amplitude eletromiográfica obtida em 1 das 3 CVM do músculo correspondente. As confiabilidades intradia e interdias foram calculadas através do coeficiente de correlação intraclasse (ICC), erro padrão da medida (SEM) e coeficiente de variação (CV). Os resultados indicaram excelente confiabilidade intradia dos valores de amplitude eletromiográfica (ICC ?0,75). A confiabilidade interdias dos valores normalizados de RMS apresentou valores variando entre bom e excelente (ICC 0,52-0,98), já os valores normalizados de ?env apresentaram valores pobres a excelente de confiabilidade (ICC 0,06-0,93). Os valores de carga produzidos durante os exercícios apresentaram excelente confiabilidade intradia e interdias (ICC ?0,97). Por fim, os resultados do presente estudo sugerem que a confiabilidade dos valores normalizados de amplitude eletromiográfica dos músculos analisados apresentam valores mais confiáveis durante os exercícios realizados com superfície estável. Já os níveis de carga empregados (80 e 100%) durante os exercícios parecem não ter influenciado nos níveis de variabilidade, talvez por serem cargas muito próximas. / The objective of the present study was to evaluate the intra and interday reliability of surface electromyography amplitude values of the scapular girdle muscles and upper limbs during the performance of 3 isometric exercises of closed kinetic chain regarding the upper limbs with the fix distal segment extremity on one stable surface and the other one on one unstable surface. In this regard, 20 healthy adults realized the exercises push-up, bench-press and wall-press with different load levels (80 and 100% maximal load). The load values produced for each exercise were recorded simultaneously to the electromyography. The individuals performed three maximal voluntary contractions (MVC) in the muscular testing position of each muscle for the obtainment of the reference value for the root mean square (RMS) normalization values and for the integrated of the linear envelope (?env). The individuals were instructed to realize at random, 3 isometric contraction series taking each exercise 6 seconds with a rest of 2 minutes between the series and the exercises. The electromyographic signals of the anterior and posterior deltoid, upper trapezius, anterior serratus, pectoralis major, biceps and triceps brachial muscle were captured by simple active differential surface electrodes, in two tests with a 7-day interval. Data were collected with a sampling frequency of 4000Hz and 500Hz low and 20Hz high passage digital filters. The RMS and ?env values were normalized by the maximal electromyographic amplitude value obtained in 1 of the 3 MVC of the corresponding muscle. The intra and interday reliabilities were calculated through the intraclass correlation coefficient (ICC), standard error measure (SEM) and coefficient of variation (CV). The results indicated an excellent intraday reliability of the electromyographic amplitude values (ICC ?0.75). The interday reliability of the RMS normalized values presented values varying between good and excellent (ICC 0.52-0.98), whereas the ?env normalized values presented poor to excellent reliability values (ICC 0.06-0.93). The load values produced during the exercises presented excellent intra and interdays reliability. Finally, the results of the present study suggest that the reliability of the electromyographic amplitude normalized values of the analyzed muscles present better values during the performance of the exercises with stable surface. However the load levels utilized during the exercises do not seem to have influenced the variability levels, eventually in view of being very close levels
169

Avaliação biomecânica da atividade dos músculos masseter e temporal usando novo dispositivo intrabucal em pacientes com síndrome de down /

Tenguan, Vera Lúcia Sizue. January 2018 (has links)
Orientador: Mônica Fernandes Gomes / Banca: José Elias Matieli / Banca: José Benedito Oliveira Amorim / Resumo: Esta pesquisa avaliou por meio de análise eletromiográfica de superfície (EMGs)os efeitos terapêuticos de um dispositivo intrabucalsobre as atividades elétricas dos músculos masseter (porção superficial) e temporal (porção anterior), bilateralmente, em pacientes com síndrome de Down. A amplitude de abertura bucal, a intensidade de força mastigatória total (FMT) foram, também, investigadas por meio de paquímetro e transdutor de força. Adicionalmente, medidas antropométricas, incluindo índice de massa corporal (IMC), circunferências do pescoço (P) e abdominal (A) e relação cintura e quadril (RCQ) foram analisadas antes e após dois meses de terapia com DM. Dez pacientes com síndrome de Down, adultos, de ambos os gêneros, foram submetidos a uma terapia com um dispositivo mastigatório (DM). Os registros eletromiográficos foram realizados para avaliar a atividade elétrica dos músculos masseter e temporal, antes e após a terapia preconizada.Diante dos resultados obtidos, conclui-se que o DM promoveu diminuição das atividades elétricas do músculo temporal em condição de repouso da mandíbula e aumento da abertura bucal, conferindo um possível equilíbrio no sistema muscular mastigatório. A atividade elétrica na contração isométrica do músculo masseter e temporal foi aumentada, sugerindo uma maximização nas unidades motoras. A discreta redução do IMC e da RCQ indica, provavelmente, uma melhoria na distribuição de gordura corporal dos pacientes.Portanto, o DM colaborou para a melhoria do... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This research evaluated the therapeutic effects of an intrabuccal device on the electrical activities of the masseter (superficial portion) and temporal (anterior portion) muscles, bilaterally, in patients with Down syndrome by means of surface electromyographic analysis (EMGs). The mouth opening amplitude and the total masticatory force intensity (FMT) were also investigated by means of a pachymeter and force transducer. In addition, anthropometric measurements, including body mass index (BMI), neck (P) and abdominal (A) circumference and waist and hip ratio (WHR) were analyzed before and after two months of DM therapy. Ten patients with Down syndrome, adults of both genders, underwent masticatory (DM) therapy. The electromyographic records were performed to evaluate the electrical activity of the masseter and temporal muscles, before and after the recommended therapy. In view of the obtained results, it was concluded that DM promoted a decrease in the electrical activities of the temporal muscle in a condition of rest of the mandible and increase of the buccal opening, conferring a possible balance in the muscular masticatory system. The electrical activity in the isometric contraction of the masseter and temporal muscle was increased, suggesting a maximization in the motor units. The discrete reduction in BMI and WHR probably indicates an improvement in patients' body fat distribution. Therefore, DM collaborated to improve the biomechanical performance of mastication / Mestre
170

A influência da fadiga nos músculos eversores durante a entorse lateral do tornozelo /

Rodrigues, Karina Aparecida. January 2016 (has links)
Orientador: José Elias Tomazini / Coorientador: Renato José Soares / Banca: Luiz Fernando Costa Nascimento / Banca: Eugênia Casella Tavares de Mattos / Resumo: A entorse do tornozelo em inversão e flexão plantar é uma das lesões mais comuns que ocorrem nas atividades de vida diária e no esporte. Embora os sintomas agudos possam se resolver rapidamente, muitos indivíduos relatam persistência de dor e instabilidade. Este tipo de lesão frequentemente acontece na fase final de um treino ou competição, e mesmo sabendo que a entorse é multifatorial, tal particularidade propicia estabelecer uma relação entre o evento da entorse e a fadiga. Diante disto, o presente estudo propõe analisar a latência e a intensidade de ativação dos músculos fibulares curto e longo em condições de fadiga, e ainda comparar indivíduos com estabilidade e instabilidade do tornozelo. Para esse fim, inicialmente foi desenvolvida uma plataforma simuladora da entorse em inversão e flexão plantar, na qual ambos os pés das voluntárias foram fixados e abaixo de onde se apoiava os pés foram acoplados transdutores de força, um de cada lado. Participaram do estudo 23 voluntárias do sexo feminino, fisicamente ativas, separadas em dois grupos: 11 fizeram parte do grupo estabilidade, não apresentavam histórico de lesão no complexo articular do tornozelo nos últimos 12 meses e outras 12 no grupo instabilidade funcional, classificadas pelo Questionário Cumberland Ankle Instability Tool. Para indução da fadiga, inicialmente foi registrada a Contração Isométrica Voluntária Máxima (CIVM) em eversão e flexão plantar. Durante a indução as voluntárias foram orientadas a manter 70% da CIVM. No momento em que a força aplicada fosse menor que 60% da CIVM o protocolo era interrompido e as voluntárias posicionadas em ortostatismo sobre a plataforma simuladora. Antes e após a fadiga foram realizadas dez simulações da entorse bilateralmente de forma randomizada e simultaneamente com o registro do sinal ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The inversion and plantar flexion ankle sprain is one of the most common injuries that occur in daily life activities and sports. Although acute symptoms can be resolved quickly, many people report persistent pain and instability. This type of injury often occurs in the final phase of a training or competition, and even though the sprain is multifactorial, such particularity provides the establishment of a relationship between the event sprain and fatigue. In this view, the present study aims to analyze the latency and activation intensity of the brevis and longus peroneus muscles in conditions of fatigue and also compare individuals with stability and instability of the ankle. For this purpose it was initially developed a simulated platform sprains in inversion and plantar flexion, in which both feet of the volunteers were fixed and below where rested his feet were coupled force transducers, one on each side. The study included 23 female volunteers, physically active, separated into two groups: 11 were part of the group stability, had no injury history in the joint complex of the ankle in the last 12 months and another 12 in functional instability group, classified by Cumberland Questionnaire Ankle Instability Tool. To induce fatigue, it was initially recorded a Contraction Isometric Maximal Voluntary (MVIC) in eversion and plantar flexion. During the induction, the participants were instructed to maintain 70% of the MVIC. At the time the force applied was below 60% of the MVIC the protocol was interrupted and the volunteers placed in standing position on the simulator platform. Before and after fatigue were held ten simulations sprain bilaterally randomly and simultaneously to record the electromyographic signal. Thus, it was observed that after the fatigue did not change the latency, but there was a reduction of muscle contraction level, ... (Complete abstract click electronic access below) / Mestre

Page generated in 0.0703 seconds