• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Energeticky úsporný dům / Energy-saving house

Lepš, Jiří January 2016 (has links)
The subject of the diploma theses is a energy-saving house. The building is designed in the Náchod cadastral, U Vodojemu street. The building is designed for the permanent housing. There is an 11 residential units. The building is designed of brick construction system ceramic blocks Porotherm. Ceiling structure is made of Porotherm Ceiling. The building is coverd with flat roof.
2

Fuktrelaterade risker vid lågenergikonstruktion i lättbetong : En studie av ett nyproducerat passivhus / Moisture related risks with aerated concrete in low energy constructions : A study of a newly produced passive house

Jansson, Sebastian, Niklasson, Erik January 2014 (has links)
Trenden i byggbranschen är att efterfrågan på täta, energisnåla byggnader ökar. Passivhus och andra lågenergikonstruktioner blir vanligare och vanligare. Riskerna med att bygga in organiskt material som trä i dessa konstruktioner har fått branschen att börja titta på alternativa material. Lättbetong är ett material som både har bärande och isolerande egenskaper. Dessutom är det inte organiskt vilket gör det okänsligt för mikrobiell påväxt. Det som är intressant med lättbetong, ur fuktsynpunkt, är att materialet levereras från tillverkare med en stor mängd byggfukt. Våren 2014 färdigställde Bollnäs Bostäder passivhus- projektet Sundsbro i Bollnäs, där lättbetong ingår i utfackningsväggarna. Sett inifrån består väggen av ett tunt lager kc-puts, lättbetong, cellplast, mineralull, kc-baserad grovputs och ytputs. I detta arbete användes projektet i Bollnäs som referensobjekt och en risk- och känslighetsanalys av väggkonstruktionen utfördes. Arbetet utreder risken för fuktrelaterade problem med väggen vid de extra uttorkningsinsatser som vidtogs i referensobjektet och vid normala uttorkningsbetingelser. Vidare utreds vilka parametrar som är viktiga för väggens fuktfunktion och vad man behöver tänka på när man projekterar och bygger i lättbetong. Arbetet har genomförts i samarbete med AK-Konsult Indoor Air AB och deras senior konsult Anders Kumlin. Fuktberäkningsprogrammet WUFI Pro 5.3 har använts för simuleringar. Beräkningarna gjordes endimensionellt på väggkonstruktionen. Resultaten med den ökade uttorkning som utfördes i referensobjektet visar inget högre fuktinnehåll längst ut i väggen på grund av byggfukt från lättbetongen som vandrar utåt. Farhågan var att så skulle kunna ske och att det skulle kunna leda till mögelproblem. Däremot visar resultaten att bygg-fukt från putsen kan fukta upp mineralullen. Det finns dock inga kända skadefall av detta slag och därför dras ändå slutsatsen att konstruktionen är riskfri. Tack vare en förutseende fukt-projektering och väl utförd uttorkning eliminerades risken för mögel. Hade inte dessa åtgärder vidtagits så visar resultaten att en liten mängd byggfukt hade kunnat vandra utåt och kondensera i mineralullen under första vintern. Då hade det funnits risk för mikrobiell påväxt. Detta visar att det är av största vikt att utföra en noggrann fuktprojektering vid byggnation av välisolerade hus i allmänhet och i synnerhet när lättbetong används. Lyckligtvis gjordes detta på ett bra sätt i referensprojektet. Känslighetsanalysen visar att isoleringens diffusionstäthet är avgörande för hur stor del av bygg-fukten som kan vandra utåt och därmed hur stor risken för problem blir. Lägre täthet ger större risk och högre täthet reducerar risken. Resultaten visar också att det är viktigt att inte montera täta skikt på insidan för tidigt. Den allmänna rekommendationen från leverantör är att lättbetongen skall torkas till 15 % fuktkvot på 50 millimeters djup innan målning och tapetsering på insida vägg får ske. Studien visar att detta är ett för högt fukttillstånd om det skikt som appliceras på insida vägg är tätt. Lättbetongen bör torkas till 5 % på 50 millimeters djup innan helt täta skikt kan monteras utan mögelrisk. / The trend in the construction industry is that the demand for tight, energy-saving buildings is rising. Passive houses and low energy constructions are becoming more and more common. The risk with using organic material in this type of constructions has made the industry look at alternative materials. Aerated concrete is a material that has both load-bearing and insulating properties. In addition to that it is not organic, which makes it insensitive to microbial growth. What is interesting with aerated concrete, from a moisture point of view, is that the material is delivered from the producer with a large amount of construction moisture. In the spring of 2014, the passive-house project Sundsbro in Bollnäs with aerated concrete in the wall construction, was finished by Bollnäs Bostäder. In this study the project in Bollnäs was used as reference object and a risk- and sensitivity analysis was made. The study examines the risk of moisture related problems with the wall construction during normal dehydration conditions and after the increased dehydration efforts that were taken in the reference project. The study also examines which parameters are important for the moisture function of the wall construction and what you need to think about when you project and build with aerated concrete. The job has been done in cooperation with AK-Konsult Indoor Air AB and their senior consultant Anders Kumlin. The moisture calculation program WUFI Pro 5.3 has been used for simulations. The results with the increased dehydration that was used in the reference project show no increased moisture content in the outer parts of the construction due to construction moisture from the concrete that wanders outwards. The concern was that so could happen and that it would lead to mould problems. However the results show that construction moisture from the exterior plaster can moisten the mineral wool. There are no known damage cases of this sort and therefore the conclusion is that the construction is free of risk. Thanks to a foreseeing moisture projection and a well performed dehydration the risk of mould was eliminated. If these measures would not have been taken, the results show that a small amount of construction moisture could have wandered outwards and condensed inside the mineral wool during the first winter. Then there would have been a risk of microbial growth. This shows that it is very important to carry out a detailed moisture projection when constructing well insulated houses in general and when using aerated concrete in particular. Fortunately this was properly done in the reference project. The sensitivity analysis shows that the diffusion resistance of the insulation decides how much of the construction moisture that can wander outwards and consequently the size of the problem risk. Results also show that it is crucial not to apply sealing layers on the inside of the wall too early. The general recommendation from the supplier is that the aerated concrete should be dried to 15 % moisture ratio on 50 millimeter depth before painting and paper hanging on the interior surface of the wall can be done. The study shows that the concrete still is too damp at that stage if the layer applied on the inside of the wall is impermeable. The concrete should be dried down to 5 % moisture ratio before sealing layers can be applied without mould risk.

Page generated in 0.0876 seconds