• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • Tagged with
  • 17
  • 17
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo do comportamento em fluência de juntas metálicas coladas / Study on creep behavior of bonded metal joints

Rodrigo Albani Queiroz 28 June 2013 (has links)
Fundação Carlos Chagas Filho de Amparo a Pesquisa do Estado do Rio de Janeiro / Juntas coladas têm se mostrado como a principal alternativa de união entre componentes fabricados em materiais distintos ou não, tendo como vantagem principal a ausência de aporte de calor e melhor distribuição de tensões. A literatura mostra que estudos anteriores foram realizados com o objetivo de caracterizar diversas propriedades associados às juntas, porém, pouco ainda se conhece sobre o comportamento dessas uniões relacionado à fluência. Os ensaios de fluência têm como principal desvantagem a baixa produtividade de resultados visto que, na maioria dos casos, os equipamentos aptos a realizarem este tipo de teste ensaiam apenas um corpo de prova por vez. Neste caso, o tratamento estatístico é baseado em uma pequena quantidade de resultados, reduzindo a confiabilidade na predição do comportamento em fluência. O Laboratório de Adesão e Aderência (LAA/UERJ/IPRJ) desenvolveu o equipamento pneumático de fluência (EPF) capaz de realizar dez ensaios simultâneos com parâmetros distintos. Este trabalho investiga o comportamento de juntas de cisalhamento simples (SLJ) compostas por substratos metálicos colados com adesivo epóxi e poliuretano. As juntas foram fabricadas em conformidade a norma ASTM D 1002, seguindo procedimento de preparo RT-003/08 TMC/CENPES/PETROBRAS. Os resultados mostram que, para projetos onde esteja prevista utilização das juntas durante longos períodos de tempo sob carregamento, conhecer apenas suas tensões médias de ruptura não é o suficiente para garantir a segurança do empreendimento. É proposto um modelo inicial do comportamento sob fluência de juntas coladas. / Bonded joints have been used as the main alternative to join components made of different materials, especially because high temperatures, like in welding process, are not required and because tensions are better distributed. Literature shows that although prior studies focused on the evolution of several mechanical properties related to joints, little is known about the creep behavior of bonded joints. Creep testings main disadvantage is the low productivity of results, since that, in most cases, testing machines capable of performing these tests only test one joint at a time. In this case, statistical treatment is made based on a small amount of results, reducing the reliability of the predictions. Thus, the Laboratory of Adhesion and Adherence (LAA/UERJ/IPRJ) developed a pneumatic creep equipment (PCE), capable of testing ten specimens simultaneously, under distinct scenario. This work looks into the behavior of single-lap joints (SLJ) made of metallic substrate and bonded with epoxy and polyurethane adhesives. The joints were produced according to ASTM D 1002 standard, following the RT-003/08 TMC/CENPES/PETROBRAS repair procedure. Results show that, for long term applications, knowing the average tensile strength of the joints isnt enough to guarantee project safety. An initial model for the creep behavior of bonded joints is proposed.
12

Análise in vitro da estabilidade de próteses totais superiores implantossuportadas e implantorretidas / Analisys of the stability of maxillary overdentures An in vitro study

Aline Tany Posch 25 February 2014 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / Os sistemas de retenção utilizados em próteses totais sobre implante (sobredentaduras) tem sido discutidos ao longo das últimas décadas a fim de se obter uma padronização a respeito do tratamento clínico desses pacientes. Considerando o importante papel da estabilidade das próteses para a eficiência mastigatória, bem como para elaboração do plano de tratamento adequado, o objetivo deste estudo foi avaliar a estabilidade das próteses implantossuportadas e/ou implantorretidas, utilizando para isso um estudo in vitro que simulou a força de mordida. Materiais e Métodos: Foram testadas quatro tipo diferentes de próteses totais: 1) G1 Prótese Total Removível Convencional; 2) G2 - Próteses Total Removível sobre Implantes (Overdenture), retida pelo sistema ERA; 3) G3 Prótese Total Removível sobre Implantes (Overdenture), retida pelo sistema de Barra com clipes e Encaixes - ORCE; e 4) G4 - Prótese Total Fixa sobre Implantes, seguindo o protocolo Brånemark e utilizando o sistema de barras-distais da marca Neodent. Cada grupo foi submetido ao carregamento em pontos específicos, localizados sobre os elementos 16 (F=300N), 26 (F=300N) e na região anterior 11/21(F=100N). A aferição da estabilidade foi feita através da mensuração do deslocamento vertical da prótese durante o a aplicação da força e a distância do local do carregamento, sobre os elementos 16, 26 e na região anterior, nos elementos 11 e 21. Os dados passaram no teste de normalidade de Shapiro-Wilk e foram submetidos à análise de variância ANOVA e à comparação múltipla através do teste de Bonferroni (p<0.05) Resultados: O tipo de sistema utilizado influenciou na movimentação vertical da prótese na região posterior contralateral à aplicação de força, sendo a movimentação vertical G1 > G2 > G3 &#8805; G4. Na movimentação vertical da prótese nos dentes anteriores, quando a força foi aplicada nos dentes posteriores (rotação para posterior), a movimentação vertical foi de G1 > G2 > G3 &#8805; G4. Durante a rotação para posterior, quando a força foi aplicada nos dentes anteriores (rotação para anterior) e a movimentação medida nos dentes posteriores, o comportamento foi de G1 > G2 > G3 > G4. Conclusão: Em duas das três situações testadas não houve diferença estatística entre a movimentação vertical entre o G3 e o G4, sugerindo que a estabilidade da overdenture retida por barra com clipes e encaixes se comportou, em relação a estabilidade, semelhante a prótese fixa sobre implantes. / The retain systems used by the complete dentures have been discussed over the past decades in order to achieve a standardization regarding to the clinical treatment of the patients. Considering the important meaning of the stability of dentures for chewing efficiency and for planning appropriate treatment, the aim of this study was to evaluate the stability of the implant-supported and implant-retained prosthesis, using an in vitro study that simulated the bite force. Materials and Methods: Four different types of dentures were tested: 1) G1 - Conventional Denture; 2) G2 Overdenture retained by the ERA system ; 3) G3 - Overdenture retained by bar system using clipes and fittings; and 4) G4 - Total implant-supported Prosthesis, following the Brånemark protocol and using Neodent`s distal bar. Each group was subjected to loading at specific points, located on the elements 16, 26 (F = 300Ncm) and at the anterior region 11/21 (F = 100Ncm). The measurement of vertical displacement during the test was taken out-lying from the loading area and at the elements 16, 26 and in the anterior region, at the element 11/21. Results: The data was analyzed by Shapiro -Wilk normality Test and than by ANOVA and multiple comparisons using the Bonferroni test. Conclusions: The retention system have influenced the vertical movement of the prosthesis in the posterior region contralateral to force application point, with the vertical movement as G1 > G2 > G3 > G4. In the vertical movement of the prosthesis at anterior point, when the force was applied to the posterior teeth, the vertical movement was G1 > G2 > G3 > G4. When the load was applied to the anterior teeth and movement was measured ate the posterior teeth, the behavior was G1 > G2 > G3 > G4. In two of the three situations simulated, there was no statistical difference between the vertical movement between the G3 and G4, suggesting that the stability of overdentures retained by bar with clips and fittings performed like fixed prosthesis.
13

Análise in vitro da estabilidade de próteses totais superiores implantossuportadas e implantorretidas / Analisys of the stability of maxillary overdentures An in vitro study

Aline Tany Posch 25 February 2014 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / Os sistemas de retenção utilizados em próteses totais sobre implante (sobredentaduras) tem sido discutidos ao longo das últimas décadas a fim de se obter uma padronização a respeito do tratamento clínico desses pacientes. Considerando o importante papel da estabilidade das próteses para a eficiência mastigatória, bem como para elaboração do plano de tratamento adequado, o objetivo deste estudo foi avaliar a estabilidade das próteses implantossuportadas e/ou implantorretidas, utilizando para isso um estudo in vitro que simulou a força de mordida. Materiais e Métodos: Foram testadas quatro tipo diferentes de próteses totais: 1) G1 Prótese Total Removível Convencional; 2) G2 - Próteses Total Removível sobre Implantes (Overdenture), retida pelo sistema ERA; 3) G3 Prótese Total Removível sobre Implantes (Overdenture), retida pelo sistema de Barra com clipes e Encaixes - ORCE; e 4) G4 - Prótese Total Fixa sobre Implantes, seguindo o protocolo Brånemark e utilizando o sistema de barras-distais da marca Neodent. Cada grupo foi submetido ao carregamento em pontos específicos, localizados sobre os elementos 16 (F=300N), 26 (F=300N) e na região anterior 11/21(F=100N). A aferição da estabilidade foi feita através da mensuração do deslocamento vertical da prótese durante o a aplicação da força e a distância do local do carregamento, sobre os elementos 16, 26 e na região anterior, nos elementos 11 e 21. Os dados passaram no teste de normalidade de Shapiro-Wilk e foram submetidos à análise de variância ANOVA e à comparação múltipla através do teste de Bonferroni (p<0.05) Resultados: O tipo de sistema utilizado influenciou na movimentação vertical da prótese na região posterior contralateral à aplicação de força, sendo a movimentação vertical G1 > G2 > G3 &#8805; G4. Na movimentação vertical da prótese nos dentes anteriores, quando a força foi aplicada nos dentes posteriores (rotação para posterior), a movimentação vertical foi de G1 > G2 > G3 &#8805; G4. Durante a rotação para posterior, quando a força foi aplicada nos dentes anteriores (rotação para anterior) e a movimentação medida nos dentes posteriores, o comportamento foi de G1 > G2 > G3 > G4. Conclusão: Em duas das três situações testadas não houve diferença estatística entre a movimentação vertical entre o G3 e o G4, sugerindo que a estabilidade da overdenture retida por barra com clipes e encaixes se comportou, em relação a estabilidade, semelhante a prótese fixa sobre implantes. / The retain systems used by the complete dentures have been discussed over the past decades in order to achieve a standardization regarding to the clinical treatment of the patients. Considering the important meaning of the stability of dentures for chewing efficiency and for planning appropriate treatment, the aim of this study was to evaluate the stability of the implant-supported and implant-retained prosthesis, using an in vitro study that simulated the bite force. Materials and Methods: Four different types of dentures were tested: 1) G1 - Conventional Denture; 2) G2 Overdenture retained by the ERA system ; 3) G3 - Overdenture retained by bar system using clipes and fittings; and 4) G4 - Total implant-supported Prosthesis, following the Brånemark protocol and using Neodent`s distal bar. Each group was subjected to loading at specific points, located on the elements 16, 26 (F = 300Ncm) and at the anterior region 11/21 (F = 100Ncm). The measurement of vertical displacement during the test was taken out-lying from the loading area and at the elements 16, 26 and in the anterior region, at the element 11/21. Results: The data was analyzed by Shapiro -Wilk normality Test and than by ANOVA and multiple comparisons using the Bonferroni test. Conclusions: The retention system have influenced the vertical movement of the prosthesis in the posterior region contralateral to force application point, with the vertical movement as G1 > G2 > G3 > G4. In the vertical movement of the prosthesis at anterior point, when the force was applied to the posterior teeth, the vertical movement was G1 > G2 > G3 > G4. When the load was applied to the anterior teeth and movement was measured ate the posterior teeth, the behavior was G1 > G2 > G3 > G4. In two of the three situations simulated, there was no statistical difference between the vertical movement between the G3 and G4, suggesting that the stability of overdentures retained by bar with clips and fittings performed like fixed prosthesis.
14

Comportamento biomecânico do reparo ósseo nos biomateriais de origem bovina / Biomechanical behavior of bone healing in biomaterials of bovine matter

Martins, Cesar Antonio de Quadros 21 December 2001 (has links)
Made available in DSpace on 2016-12-06T17:07:09Z (GMT). No. of bitstreams: 1 CesarMartins.pdf: 970860 bytes, checksum: 6ad6b24dacadddaad307316c6a4edb43 (MD5) Previous issue date: 2001-12-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The purpose of this study was to analyze the ultimate strength and displacement behavior of healed 3.5-mm segmental radius defects in seventeen adult male rabbits in a fourty-two days follow-up. The defect was filled out with biomaterials (ten radius) such as bone morphogenetic protein, inorganic bovine bone matrix, organic bovine bone matrix and bovine collagen in one group (group I). Group II (seven radius) received fresh-frozen allograft bone obtained from a rabbit bone-banking created for this study. The opposite limbs were the control group (group III) with seventeen radius. The three point bending and the displacement were recorded in all specimens studied. The one-way analysis of variance (p£ 0.05) and the variation coefficient in the whole three groups. Significant difference in the ultimate strengh were found between group I and III (p= 0.0009). The variable ultimate strength of group I has presented a coefficient of variation of 87%, group II has presented a oefficient of variation of 66% and the control group a coefficient of variation of 31%. Group I in the variable displacement has presented a coefficient do variation of 70%, group II has presented a coefficient of variation of 60% and group III 33%. Beetwen groups I and II the least variated group was group II in both variables. However, four in ten non-unions were recorded in the biomaterial group. All allograft group specimens have shown bone healing in the follow-up period. This study do not demonstrate the effectiveness of bovine origin biomaterials as suitable on bone formation. Clinical Relevance: Segmental Bone loss due to trauma, tumor resection or other causes are one of the most challenging problems in orthopaedic surgery. Several materials have been used as bone regenerator, even thou bone tissue has a very known potential of healing. Allograft bone tissue is very attractive possibility but presents a high disease transmission risk. Although autograft tissue has a short stock tissue for some situations in the daily orthopaedic activity, it remains the gold standard for most surgeons. In some cases, bovine origin biomaterials are the only choice available to solve the bone loss situations. / O presente estudo tem como objetivo identificar a resistência mecânica óssea e o deslocamento do osso neoformado utilizando-se biomateriais de origem bovina e enxerto homólogo no preenchimento de uma falha de 3,5 mm no rádio em 17 dos 19 coelhos adultos machos da raça nova zelândia, com massa de 3,5 a 5,0 Kg. Os biomateriais são substâncias biologicamente ativas, que apresentam efeito osteogênico, isto é, ativam a formação de osso novo nos organismos vivos. Neste estudo foram utilizados três grupos: grupo I com enxerto ósseo orgânico e inorgânico bovino, pool de proteína morfogenética bovina e colágeno bovino, como biomateriais em dez animais. Dois animais foram submetidos à retirada das asas ilíacas para posterior congelamento e implantação em sete animais formando o grupo II, ou enxerto homólogo. O grupo III ou controle consistiu nos rádios não operados dos 17 animais. Após 42 dias, os animais foram sacrificados e os rádios foram submetidos ao teste de flexão em três pontos, com a aplicação da carga no sítio da regeneração, sendo avaliados a carga máxima e o deslocamento neste ensaio mecânico. O teste estatístico realizado foi ANOVA - um caminho, com p£0,05 para três amostras, post-hoc de Scheffé e o coeficiente de variação. Quanto à carga máxima para a ruptura, o grupo I (biomateriais) apresentou uma média de 77,1 N ± 67,2N e um CV (coeficiente de variação) de 87%, o grupo II (enxerto homólogo) apresentou uma média de 154,8 N ±103,2 N, com um CV de 66%, já o grupo controle obteve uma média de 201,8 N ± 63,0N e um CV de 31%, que caracterizou uma diferença estatisticamente significante entre o grupo I com o grupo controle (p=0,0009). Quanto a variável deslocamento, o grupo I apresentou uma média de 1,0 mm ± 0,7mm com um CV de 70%, o grupo do II apresentou uma média de 1,0 mm ± 0,6 mm com um CV de 60% e o grupo III uma média de 0,9 mm ± 0,3 mm e CV de 33%, não demonstrando diferença estatisticamente significante (p=0,49). Quatro espécimes do grupo dos biomateriais que fizeram parte do estudo estatístico apresentaram não consolidação na falha criada, por outro lado os espécimes preenchidos com enxerto homólogo consolidaram em todos os casos. Em conclusão, os enxertos homólogos apresentaram consolidação satisfatória demonstrando um pico de carga máxima com valores próximos aos do grupo controle. Porém, os biomateriais demonstraram uma variação intragrupo muito alta devido às não consolidações, com média de carga máxima muito baixa.
15

Estudo do comportamento em fluência de juntas metálicas coladas / Study on creep behavior of bonded metal joints

Rodrigo Albani Queiroz 28 June 2013 (has links)
Fundação Carlos Chagas Filho de Amparo a Pesquisa do Estado do Rio de Janeiro / Juntas coladas têm se mostrado como a principal alternativa de união entre componentes fabricados em materiais distintos ou não, tendo como vantagem principal a ausência de aporte de calor e melhor distribuição de tensões. A literatura mostra que estudos anteriores foram realizados com o objetivo de caracterizar diversas propriedades associados às juntas, porém, pouco ainda se conhece sobre o comportamento dessas uniões relacionado à fluência. Os ensaios de fluência têm como principal desvantagem a baixa produtividade de resultados visto que, na maioria dos casos, os equipamentos aptos a realizarem este tipo de teste ensaiam apenas um corpo de prova por vez. Neste caso, o tratamento estatístico é baseado em uma pequena quantidade de resultados, reduzindo a confiabilidade na predição do comportamento em fluência. O Laboratório de Adesão e Aderência (LAA/UERJ/IPRJ) desenvolveu o equipamento pneumático de fluência (EPF) capaz de realizar dez ensaios simultâneos com parâmetros distintos. Este trabalho investiga o comportamento de juntas de cisalhamento simples (SLJ) compostas por substratos metálicos colados com adesivo epóxi e poliuretano. As juntas foram fabricadas em conformidade a norma ASTM D 1002, seguindo procedimento de preparo RT-003/08 TMC/CENPES/PETROBRAS. Os resultados mostram que, para projetos onde esteja prevista utilização das juntas durante longos períodos de tempo sob carregamento, conhecer apenas suas tensões médias de ruptura não é o suficiente para garantir a segurança do empreendimento. É proposto um modelo inicial do comportamento sob fluência de juntas coladas. / Bonded joints have been used as the main alternative to join components made of different materials, especially because high temperatures, like in welding process, are not required and because tensions are better distributed. Literature shows that although prior studies focused on the evolution of several mechanical properties related to joints, little is known about the creep behavior of bonded joints. Creep testings main disadvantage is the low productivity of results, since that, in most cases, testing machines capable of performing these tests only test one joint at a time. In this case, statistical treatment is made based on a small amount of results, reducing the reliability of the predictions. Thus, the Laboratory of Adhesion and Adherence (LAA/UERJ/IPRJ) developed a pneumatic creep equipment (PCE), capable of testing ten specimens simultaneously, under distinct scenario. This work looks into the behavior of single-lap joints (SLJ) made of metallic substrate and bonded with epoxy and polyurethane adhesives. The joints were produced according to ASTM D 1002 standard, following the RT-003/08 TMC/CENPES/PETROBRAS repair procedure. Results show that, for long term applications, knowing the average tensile strength of the joints isnt enough to guarantee project safety. An initial model for the creep behavior of bonded joints is proposed.
16

Estudo comparativo dos efeitos do ultra-som e do laser de baixa intensidade no reparo ósseo de tíbia de rato / Comparative study of ultra-sound and low intensity laser therapy effects on bone healing in rats tibia

Ana Paula Rebucci Lirani 24 March 2004 (has links)
Vários estudos têm avaliado os efeitos do ultra-som e da radiação laser de baixa intensidade separadamente no reparo ósseo. No entanto, são escassas as comparações entre estas duas modalidades terapêuticas. Este estudo teve por objetivo avaliar e comparar, através de análise histomorfométrica e ensaio mecânico de flexão em três pontos, as conseqüências que estes agentes físicos podem trazer ao reparo do tecido ósseo em osteotomias transversais experimentais em tíbias de ratos. Foram utilizados 48 ratos com fratura cirúrgica unilateral parcial do terço superior de tíbia. Os animais foram divididos em três grupos de 16 animais. Em um grupo, o membro fraturado foi tratado com ultra-som pulsado de baixa intensidade (freqüência de 1,5 MHz, ciclo de trabalho 1:4, intensidade SATA 30 mW/centímetro quadrado) em sessões de 20 minutos, 5 vezes por semana, em 12 dias de tratamento. Em um segundo grupo, o membro fraturado foi tratado com laser As-Ga-Al (112,5 J/centímetro quadrado, 780 nm, 30 mW) em sessões de 2,5 minutos, 5 vezes por semana, em 12 dias de tratamento. O terceiro grupo serviu de controle, sendo submetido à mesma cirurgia na tíbia direita mas não recebeu qualquer tratamento. No ensaio mecânico, a carga no limite máximo suportada pelo grupo tratado com laser foi significantemente maior (p < 0,05) que os grupos tratado com ultra-som e controle. Na análise histomorfométrica, o grupo tratado com laser apresentou significância estatística quanto ao número e superfície de osteoblastos e volume e superfície de osteóide e o grupo ultra-som obteve significância para as superfícies de reabsorção e de osteoclastos. Pode-se concluir que o ultra-som acelerou o reparo ósseo (em relação ao grupo controle) por viabilizar mais rapidamente a fase de reabsorção, enquanto que a terapia laser foi capaz de acelerar ainda mais este processo por já promover predomínio de formação óssea no décimo nono dia pós-cirúrgico no modelo experimental utilizado neste estudo / Many studies have assessed the effects of ultra-sound and low intensity laser therapy separatedly in bone repair. However, the comparison between these two therapeutic modalities is rare. The objective of this study was to verify and compare, through histomorphometrical analysis and a three-point bending test, the consequences of these physical agents on bone healing in animals. 48 male Wistar rats were used with tibial bone partial osteotomy, divided into 3 groups of 16. In one group, rats had their fractured limb treated with GaAIAs laser (780 nm, 30 mW, 112,5 J/square contimeter) in 12 five times-a-week sections. In another group, rats were treated with low intensity pulsed ultra-sound (1,5 MHz, 30 mW/square centimeter) in 12 five times-a-week sections too. In a third group, animals were taken as control, being submitted to the same osteotomy but receiving no treatment. After 19 days the tibias were extracted and half of them were submitted to a three-point bending test and the other half to histomorphometric analysis. During the bending test, the maximum load at failure of the tibia in the laser group was significantly higher (p<0.05). Histomorphometry showed statistical significance in osteoblasts number and surface and osteoid volume and surface for the laser group, and eroded and osteoclasts surfaces for the ultra-sound group. Ultra-sound was able to enhance bone healing (compared to control group) by speeding up the reabsorption phase, while low intensity laser therapy could accelerate this process even more by promoting mostly new bone formation 19 days after osteotomy in this experimental model
17

Estudo da resistência mecânica do ligamento cruzado anterior de ratos submetidos à imobilização / Immobilization effects on strength of the rat anterior cruciate ligament

Cristiane Spolador Pátaro Domingos 14 August 1998 (has links)
O efeito da imobilização no ligamento cruzado anterior, através de atadura gessada por um período de 6 semanas, foi estudado em ratos machos, adultos da raça Wistar. Para esta análise foram desenvolvidos dispositivos que permitiram a fixação do espécime à Máquina de Ensaio Universal e a realização de ensaio mecânico de tração. Através desta metodologia a tração foi aplicada na interlinha articular, somente na junção osso-ligamento-osso. Os dados obtidos foram analisados, quanto à carga máxima, deformação máxima, e energia absorvida pelo ligamento até o momento da ruptura. Nos resultados obtidos não foi observado diferença estatisticamente significativa na resistência do ligamento cruzado anterior, do membro imobilizado em relação ao membro não imobilizado, o que nos indica que provavelmente um período de 6 semanas de imobilização o qual permite pequeno grau de movimento como é o caso da imobilização gessada, não foram suficientes para produzir alterações na resistência ligamentar. / The effects of immobilization through plaster cast for 6 weeks on the mechanical properties of the anterior cruciate ligament (ACL) of Wistar adult mate rats were analysed. Special grips for retaining the specimens during traction tests in a universal test machine were developed. In this way, traction forces could be applied directly to bone-ligament-bone complex. Maximal load, maximal deformation, stiffness and absorbed energy up to the rupture point were considered, compared to the contralateral (normal) ACL. No significant difference could be demonstrated leading us to the conclusion that, at least for the considered lenght of time of immobilization (6 weeks), no important changing in the mechanical properties of the LCA occurred. This contradictory result compared to others in the literature was imputed to the different methodology here employed, where the forces could be applied directly to bone-ligament-bone complex, instead of the femur, anterior cruciate ligament and part of tibia. In addition, the relativily short period by immobilization and the movement permited by the slack immobilization could also be responsabilite for the results.

Page generated in 0.3201 seconds