• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 77
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 77
  • 77
  • 45
  • 25
  • 21
  • 17
  • 16
  • 16
  • 13
  • 13
  • 12
  • 12
  • 11
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação do impacto de dois diferentes métodos de higiene oral com clorexidina na prevenção de pneumonia associada à ventilação mecânica / Two methods of oral hygiene with chlorhexidine in preventing of ventilator-associated pneumonia

Félix, Luan Cartaxo 24 February 2016 (has links)
FÉLIX, L. C. Avaliação do impacto de dois diferentes métodos de higiene oral com clorexidina na prevenção de pneumonia associada à ventilação mecânica. 2016. 59 f. Dissertação (Mestrado em Odontologia) - Faculdade de Farmácia, Odontologia e Enfermagem, Universidade Federal do Ceará, Fortaleza, 2016. / Submitted by Erika Fernandes (erikaleitefernandes@gmail.com) on 2016-04-25T11:42:17Z No. of bitstreams: 1 2016_dis_lcfelix.pdf: 1728372 bytes, checksum: 78f0771f6ac8ef27008f5edc69c05585 (MD5) / Approved for entry into archive by Erika Fernandes (erikaleitefernandes@gmail.com) on 2016-04-25T11:42:26Z (GMT) No. of bitstreams: 1 2016_dis_lcfelix.pdf: 1728372 bytes, checksum: 78f0771f6ac8ef27008f5edc69c05585 (MD5) / Made available in DSpace on 2016-04-25T11:42:26Z (GMT). No. of bitstreams: 1 2016_dis_lcfelix.pdf: 1728372 bytes, checksum: 78f0771f6ac8ef27008f5edc69c05585 (MD5) Previous issue date: 2016-02-24 / Ventilator-associated pneumonia (VAP) is a lung infection that affects patients under mechanical ventilation (MV). The main pathophysiological mechanism of VAP is the aspiration of bacterial pathogens of the oral cavity and pharynx. The reduction of bacterial colonization in the oral cavity is one of the preventive measures for this infection, therefore, this study aimed to evaluate the efficacy of two techniques of oral hygiene in preventing VAP. A prospective, randomized clinical trial was conducted with patients hospitalized in the ICU of Hospital Geral Dr. Waldemar Alcântara (HGWA). The volunteers were divided into two groups: the method performed as hospital routine that used gauze soaked in 0.12% chlorhexidine digluconate every 8 hours (Gauze Group), and another method that was performed with a manual toothbrush imbibed in the same solution every 8 hours (Toothbrush Group). A minimum sample of 23 patients per group was estimated to yield a sample with 90% power and 95% confidence (paired t test). The primary outcome was the occurrence of VAP. This infection was investigated until the end of MV. Secondary outcomes were: [1] assessment of oral health (visible plaque, lingual plate and possible alterations intraoral and perioral normality) and [2] presence / absence of respiratory microorganisms in dental and lingual plate. These secondary outcomes were evaluated in two phases: in the first 24 hours of MV and 72 hours after the first evaluation. The two techniques showed low incidence of ventilator-associated pneumonia (VAP) and there was no statistically significant difference between the two oral hygiene methods in preventing this infection. K. pneumoniae and P. aeruginosa were the bacterial species most often isolated. There was no statistically significant difference between the two oral hygiene methods when comparing the efficacy in reducing the incidence of respiratory microorganisms. In the 2nd assessment, less visible plaque index was observed in the group that used the toothbrush. / Pneumonia associada à ventilação mecânica (PAV) é uma infecção pulmonar que afeta pacientes submetidos à ventilação mecânica (VM). O principal mecanismo fisiopatológico da PAV é a aspiração de patógenos bacterianos da cavidade oral e da faringe. Como a redução da colonização bacteriana na cavidade oral é uma das medidas técnicas de higiene oral na prevenção da PAV, o presente estudo teve como objetivo avaliar a eficácia de duas técnicas de higiene oral na prevenção da PAV. Foi realizado um ensaio clínico prospectivo e randomizado, com pacientes internados nas Unidades de Terapia Intensiva do Hospital Geral Dr. Waldemar Alcântara. Os voluntários foram alocados em dois grupos: Grupo Gaze (n=28), higiene bucal utilizada como padrão no Hospital, sendo esta realizada com gaze embebida em digluconato de clorexidina 0,12%; Grupo Escova (n=30), higiene bucal com escova dental manual embebida na mesma solução. Uma amostra mínima de 23 pacientes, por grupo, foi estimada para se obter uma amostra com 90% de poder e 95% de confiança (teste t pareado). O desfecho primário foi a ocorrência de PAV, sendo esta infecção investigada até o término da VM. Os desfechos secundários foram: [1] avaliação da saúde bucal (placa visível, placa lingual e eventuais alterações da normalidade intraoral e perioral) e [2] presença/ausência de microrganismos respiratórios na placa dental e lingual. Estes desfechos secundários foram avaliados em dois momentos: nas primeiras 24 horas de VM e 72 horas após a primeira avaliação. As duas técnicas apresentaram baixa incidência de PAV, e não houve diferença estatisticamente significativa entre os dois métodos de higiene oral na prevenção desta infecção. K. pneumoniae e P. aeruginosa foram as espécies bacterianas mais frequentemente isoladas. Não houve diferença estatisticamente significativa entre os dois métodos de higiene oral, quando comparando a eficácia na redução da incidência de microrganismos respiratória. Na 2ª avaliação, um menor índice de placa visível foi observado no grupo que utilizou a escova dental.
22

Avaliação do efeito da fumaça do cigarro na translucidez da resina composta: influência do selante da superfície e da escovação

Takeuchi, Cristina Yoshie Garcia [UNESP] 09 February 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-02-09Bitstream added on 2014-06-13T19:10:19Z : No. of bitstreams: 1 takeuchi_cyg_me_arafo.pdf: 548399 bytes, checksum: dc80caffca8640c92d69a902fa0d9a40 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar in vitro a translucidez da resina composta, em função do efeito do selamento superficial; da exposição à fumaça de cigarro e da escovação. Para tanto, 40 corpos-de-prova (10 mm X 1 mm) foram confeccionados com resina composta Filtek Z250 divididos aleatoriamente em 4 grupos (n=10), sendo: G1 - controle (saliva artificial e sem selante); G2 - saliva artificial e com selante (Protect-it!); G3 - cigarro e sem selante e G4 - cigarro e com selante. Os espécimes foram submetidos à avaliação da translucidez em diferentes tempos: T1: imediatamente após a confecção; T2: após o polimento; T3: após o selamento (G2 e G4); T4: após o 1º tratamento (10 dias imersos em saliva artificial ou manchados por 200 cigarros); T5: após serem submetidos a 1ª escovação (850 ciclos); T6: após o 2º tratamento (10 dias imersos em saliva artificial ou manchados por 200 cigarros); T7: após serem submetidos a 2ª escovação (850 ciclos); T8: após o 3º tratamento (10 dias imersos em saliva artificial ou manchados por 200 cigarros); T9: após serem submetidos a 3ª escovação (850 ciclos). Os valores de translucidez foram obtidos no aparelho JOUAN e analisados estatisticamente pelos testes de Mann-Whitney, Kruskal-Wallis, Friedman, seguidos da Análise de Variância e teste de Tukey. Observou-se que o selamento não provocou alteração significativa da translucidez dos espécimes e que após a 1ª escovação ocorreu aumento significativo, mantendo-se constante nos G1 e G2, e para os G3 e G4 o cigarro provocou severo manchamento que foi removido parcialmente pela escovação. Concluindo que o selamento não promoveu melhora na translucidez com o tempo e nem protegeu contra manchamento, sendo que a escovação não restabeleceu a translucidez. / The aim of this study was to assess in vitro the translucency of the composite resin, in function of the effect of the surface sealing; after the exposition to the cigarette smoke and of the toothbrushing. Forty specimens (10mm X 1mm) they were made with composite resin Filtek Z250 divided into 4 groups (n = 10), being: G1 - it controls (it artificial saliva and without sealant); G2 - it artificial saliva and with sealant (Protect-it!); G3 - cigarette and without sealant and G4 - cigarette and with sealant. The specimens were submitted to the evaluation of the translucency in different times: T1: immediately after the making; T2: after the polishing; T3: after the sealing (G2 and G4); T4: after the 1st treatment (10 submerged days in artificial saliva or spotted for 200 cigarettes); T5: after they be submitted to 1st toothbrushing (850 cycles); T6: after the 2nd treatment (10 submerged days in artificial saliva or spotted for 200 cigarettes); T7: after they be submitted to 2nd toothbrushing (850 cycles); T8: after the 3rd treatment (10 submerged days in artificial saliva or spotted for 200 cigarettes); T9: after they be submitted to 3rd toothbrushing (850 cycles). The translucency values were obtained in the JOUAN apparel and analyzed by the tests of Mann-Whitney, Kruskal-Wallis and Friedman, following by the Analysis of Variance and test of Tukey. It was observed that the sealing didn't provoke significant alteration of the translucency of the specimens and that after to 1st toothbrushing it happened significant increase, staying constant in G1 and G2, and for G3 and G4 the cigarette provoked severe staining that was removed partially by the toothbrushing. Concluding that the sealing didn't promote improvement in the translucency with the time and nor it protected against staining, and the toothbrushing didn’t reestablish the translucency.
23

Efeito de diferentes métodos de higienização na remoção de um adesivo para prótese e na redução da microbiota bucal de usuários de prótese total: estudo in vivo

Nunes, Élen Massaro [UNESP] 29 May 2015 (has links) (PDF)
Made available in DSpace on 2016-12-09T13:52:21Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-05-29. Added 1 bitstream(s) on 2016-12-09T13:55:26Z : No. of bitstreams: 1 000867886.pdf: 3099983 bytes, checksum: fa32c79f281a8eb7caeb832bb2e68c95 (MD5) / Esse estudo avaliou in vivo (n=20) a eficácia de diferentes métodos de higienização na remoção de um adesivo para prótese total (Ultra Corega creme) e na redução da carga microbiana oral. Os métodos de higienização foram escovação das próteses com escova de cerdas macias utilizando: A (água em temperatura ambiente), B (água em temperatura ambiente + sabão de coco), C (água em temperatura ambiente + dentifrício) e D (água + imersão em solução de perborato de sódio por 5 minutos). Foi realizada coleta de saliva antes e após a utilização do adesivo e realização dos métodos de higienização. As superfícies internas das próteses totais superiores foram coradas com índigo carmim 0,4% e as áreas cobertas por adesivo foram quantificadas (%) por meio de um método fotográfico e auxílio de um software (Image Tool). Para a análise microbiológica, a saliva coletada foi diluída e plaqueada em um meio de cultura não-seletivo (Mueller Hintön Agar) e em meios de cultura para Candida spp (Sabouraud Dextrose Agar e CHROMagar Candida). Após o período de incubação (48 horas/37ºC), as espécies de Candida foram identificadas e o número de unidades formadoras de colônias (UFC/mL) foram calculados. Conclui-se que a escovação combinada com a imersão das próteses em perborato de sódio foi mais eficaz na remoção do adesivo quando comparado com a escovação com água (Dunn, p=0,004). Para os meios de cultura não seletivo (ANOVA,p>0,05) e seletivos para Candida spp (Friedman, p>0,05), não foi observada influência dos métodos de higienização na carga microbiana oral. / This study evaluated in vivo (n=20) the effectiveness of different cleaning methods in removing an adhesive for dentures (Ultra Corega cream) and the reduction of microorganisms in the oral microbiota. The cleaning methods were brushing the dentures with soft bristle brush using: A (room temperature water), B (water at room temperature + coconut soap), C (room temperature + dentifrice in water) and D (water+immersion in sodium perborate solution for 5 minutes). Saliva samples were taken before and after using the adhesive and realization of cleaning methods. The inner surfaces of the upper dentures were stained with 0.4% indigo carmine and the adhesive-covered areas were quantified (%) by means of a photographic method and assistance for a software (Image Tool). For microbiological analyzes the collected saliva was diluted and plated in a medium non-selective medium (Mueller Hinton Agar) and culture media for Candida spp (Sabouraud Dextrose Agar and CHROMagar Candida). After the incubation period (48 hours / 37°C), Candida species were identified and the number of colony forming units (CFU / ml) were calculated. It was concluded that the brushing combined with the immersion of the prosthesis into sodium perborate was more effective in removing the adhesive as compared with brushing with water (Dunn, p=.004). For the non selective media (ANOVA,p>0,05) and selective for Candida spp (Friedman, p>0,05), there was no influence of the cleaning methods on the oral microbiota.
24

Efeito de diferentes métodos de higienização na remoção de um adesivo para prótese e na redução da microbiota bucal de usuários de prótese total: estudo in vivo /

Nunes, Élen Massaro. January 2015 (has links)
Orientador: Ana Carolina Pero / Co-orientador: / Banca: Marco Antonio Compagnoni / Banca: Claudia Helena Lovato da Silva / Resumo: Esse estudo avaliou in vivo (n=20) a eficácia de diferentes métodos de higienização na remoção de um adesivo para prótese total (Ultra Corega creme) e na redução da carga microbiana oral. Os métodos de higienização foram escovação das próteses com escova de cerdas macias utilizando: A (água em temperatura ambiente), B (água em temperatura ambiente + sabão de coco), C (água em temperatura ambiente + dentifrício) e D (água + imersão em solução de perborato de sódio por 5 minutos). Foi realizada coleta de saliva antes e após a utilização do adesivo e realização dos métodos de higienização. As superfícies internas das próteses totais superiores foram coradas com índigo carmim 0,4% e as áreas cobertas por adesivo foram quantificadas (%) por meio de um método fotográfico e auxílio de um software (Image Tool). Para a análise microbiológica, a saliva coletada foi diluída e plaqueada em um meio de cultura não-seletivo (Mueller Hintön Agar) e em meios de cultura para Candida spp (Sabouraud Dextrose Agar e CHROMagar Candida). Após o período de incubação (48 horas/37ºC), as espécies de Candida foram identificadas e o número de unidades formadoras de colônias (UFC/mL) foram calculados. Conclui-se que a escovação combinada com a imersão das próteses em perborato de sódio foi mais eficaz na remoção do adesivo quando comparado com a escovação com água (Dunn, p=0,004). Para os meios de cultura não seletivo (ANOVA,p>0,05) e seletivos para Candida spp (Friedman, p>0,05), não foi observada influência dos métodos de higienização na carga microbiana oral. / Abstract: This study evaluated in vivo (n=20) the effectiveness of different cleaning methods in removing an adhesive for dentures (Ultra Corega cream) and the reduction of microorganisms in the oral microbiota. The cleaning methods were brushing the dentures with soft bristle brush using: A (room temperature water), B (water at room temperature + coconut soap), C (room temperature + dentifrice in water) and D (water+immersion in sodium perborate solution for 5 minutes). Saliva samples were taken before and after using the adhesive and realization of cleaning methods. The inner surfaces of the upper dentures were stained with 0.4% indigo carmine and the adhesive-covered areas were quantified (%) by means of a photographic method and assistance for a software (Image Tool). For microbiological analyzes the collected saliva was diluted and plated in a medium non-selective medium (Mueller Hinton Agar) and culture media for Candida spp (Sabouraud Dextrose Agar and CHROMagar Candida). After the incubation period (48 hours / 37°C), Candida species were identified and the number of colony forming units (CFU / ml) were calculated. It was concluded that the brushing combined with the immersion of the prosthesis into sodium perborate was more effective in removing the adhesive as compared with brushing with water (Dunn, p=.004). For the non selective media (ANOVA,p>0,05) and selective for Candida spp (Friedman, p>0,05), there was no influence of the cleaning methods on the oral microbiota. / Mestre
25

Avaliação in vitro da rugosidade superficial de resinas compostas após escovação simulada com diferentes dentifrícios

Monteiro, Bruna January 2014 (has links)
Made available in DSpace on 2014-08-12T02:02:42Z (GMT). No. of bitstreams: 1 000460167-Texto+Completo-0.pdf: 3148675 bytes, checksum: 0fca29414ee88deb42284c417ac20415 (MD5) Previous issue date: 2014 / Aim: Evaluate, in vitro, the surface roughness of two composite resins submitted to a simulated wear test with three different dentifrices, applying simulated periods of six months, one year and two years of tooth brushing. Materials and Methods: Thirty-six samples of Z350XT and 36 samples of Empress Direct were built and randomly divided into three groups (n=12) according to the dentifrice used (Colgate Total 12 Clean Mint [CT12] (control), Colgate Sensitive Pro-Alívio [CS], Oral B Pro-saúde Whitening [OBW]). The samples were submitted to 5,000, 10,000 or 20,000 cycles of simulated tooth brushing. After each simulated period, the surface roughness of the samples was measured using a roughness tester. Results: According to three-way ANOVA, dentifrice (p=0. 044) and period (p=0. 000) were significant. There was no significance for the composite resin factor (p=0. 381) and for the interaction (p>0. 05). CT12 presented the lower surface roughness (0. 269 μm), not differing statistically from CS (0. 300 μm). The highest surface roughness was obtained for OBW (0. 390 μm), not differing statistically from CS. The higher value was obtained after 20,000 cycles (0. 584 μm) of simulated tooth brushing, differing statistically from the other two periods. Conclusions: Z350 XT and Empress Direct presented similar surface roughness after all cycles of simulated tooth brushing. The surface roughness of the composites increased with brushing time. The whitening toothpaste OBW caused higher surface roughness in both composite resins. / Objetivo: Avaliar, in vitro, a rugosidade superficial de duas resinas compostas submetidas à escovação simulada com três diferentes dentifrícios, em períodos de seis meses, um ano e dois anos. Materiais e Métodos: Foram confeccionadas 36 amostras da resina composta Z350 XT e 36 da resina Empress Direct, sendo divididas aleatoriamente em três grupos de 12 (n=12), conforme o dentifrício utilizado (Colgate Total 12 Clean Mint [CT12] (controle), Colgate Sensitive Pro-Alívio [CS], Oral B Pro-Saúde Whitening [OBW]). As amostras foram submetidas a 5. 000, 10. 000 e 20. 000 ciclos de escovação. Após cada período simulado, as amostras de resinas compostas tiveram a rugosidade de superfície mensurada por um rugosímetro. Resultados: Segundo a ANOVA de três fatores, os fatores dentifrício (p=0,044) e tempo (p=0,000) foram significativos. Não houve significância para o fator resina composta (p=0,381) e para a interação entre os fatores (p>0,05). O dentifrício CT12 apresentou a menor média de rugosidade superficial (0,269 μm), não diferindo estatisticamente do dentifrício CS (0,300 μm). A maior média de rugosidade superficial foi obtida com o dentifrício OBW (0,390 μm), não diferindo estatisticamente do CS. A maior média de rugosidade superficial foi obtida após 20. 000 ciclos de escovação (0,584 μm), diferindo estatisticamente dos outros tempos. Conclusões: Z350 XT e Empress Direct apresentaram rugosidade superficial semelhante após todos os ciclos de escovação. A rugosidade superficial das resinas compostas aumentou com o tempo de escovação. O dentifrício clareador OBW causou maior rugosidade de superfície em ambas as resinas compostas.
26

Avaliação de massa e rugosidade superficial de pastilhas de Ti-6Al-4V com aplicação de nanopartículas de prata submetidos ao teste de escovação / Evaluation of mass and surface roughness of Ti-6Al-4V tablets with silver nanoparticles application submitted to brushing test

Vinícius Rizzo Marques 09 December 2015 (has links)
Este estudo teve por objetivo avaliar a variação da massa e rugosidade de pastilhas de Ti-6Al-4V com e sem aplicação superficial de nanopartículas de prata coloidal (BSafe®) de dimensões 1,5 cm; 0,5 cm e 0,2 cm, submetidas à teste de escovação e imersão pelo período experimental de 10 anos. No teste de escovação, quinze espécimes de Ti-6Al-4V (TE), quinze com B-Safe® (BE) e quinze de PMMA (PE) como controle foram subdivididos em três condições de escovação: dentifrício comum (DC), dentifrício experimental (DE) e controle com água destilada (H2O) por 200 mil ciclos em máquina de escovação. Os resultados foram submetidos ao teste ANOVA a 2 critérios (condição de escovação e ciclos) e teste de Tukey (α=0,05) para comparações múltiplas. Foi observada variação de massa apenas quando a condição de escovação foi DC nos espécimes do grupo PE e TE. Houve diferença estatisticamente significante nos valores da variação de rugosidade no grupo TE e PE quando a condição de escovação foi DC; no grupo BE, houve diferença quando a condição foi DC e DE, porém em DE houve redução dos valores médios. No teste de imersão, objetivando analisar a ação dos dentifrícios sem o atrito das cerdas, seis espécimes de Ti-6Al-4V (TI) e seis com B-Safe® (BI) foram subdivididos em três condições de imersão: DC, DE e H2O pelo período de 244 horas. Os resultados foram submetidos ao teste t de student pareado. Não foi observada diferença estatística entre as variações de massa e rugosidade de nenhum dos corpos de prova após o teste. Complementar aos ensaios, foi realizado um protocolo de desinfecção com terapia fotodinâmica com azul de metileno pelo período de 4 semanas nos espécimes escovados. Após todos os testes, foi realizada espectrometria de energia dispersiva de raios-X (EDS) para caracterização dos elementos químicos presentes nos espécimes, onde não se observou variações. Os resultados sugerem que o DE é mais indicado para utilização com implantes, enquanto DC apresenta um poder abrasivo capaz de danificar a superfície do Ti-6Al- 4V. Não foi observado nenhum indício de corrosão em nenhum grupo testado. / This study aimed to evaluate the variation of mass and roughness of Ti-6Al-4V tablets with and without superficial application of colloidal silver nanoparticles (BSafe®) with dimensions of 1,5 cm; 0,5 cm and 0,2 cm, submitted to brushing and immersion test for an experimental period of 10 years. For the brushing test, fifteen specimens of Ti-6Al-4V (TE), fifteen with B-Safe® (BE) and fifteen of PMMA (PE) as control were subdivided into three brushing conditions: normal toothpaste (DC), experimental toothpaste (DE) and control with distilled water (H2O) by 200 thousand cycles in brushing machine. The results were submitted to the ANOVA test on 2 criteria (brushing condition and cycles) and the Tukey test ((α= 0,05) for multiple comparisons. Mass variation was observed only when the brushing condition was DC, in PE and TE groups. Statistically significant difference was observed in the values of roughness variation on TE and PE group when the brushing condition was DC; in the BE group, there was difference when the condition was DC and DE, however in DE there was reduction of the average values. In the immersion test, aiming to analyze the action of toothpastes without the friction of the bristles, six specimens of Ti-6Al-4V (TI) and six with B-Safe® (BI) were subdivided into three immersion conditions: DC, DE and H2O for a period of 244 hours. The results were submitted to paired student t-test. No statistical difference was observed between mass and roughness variation for any of the specimens after the test. Additional to the tests, a disinfection protocol with photodynamic therapy with methylene blue was performed for a 4-week period on the brushed specimens. After all tests, Energydispersive X-ray Spectroscopy (EDS) was performed for characterization of the chemical elements present in the specimens, in which no variations were observed. The results suggest that DE is most suitable for use with implants, while DC has a higher abrasive power capable of damaging the Ti-6Al-4V surface. There was no evidence of corrosion in any tested group.
27

Efeito da escovação simulada nas propriedades de zircônias estabilizadas por ítria (Y-TZP) envelhecidas hidrotérmicamente /

Astuti, Stefhany Costa Barbizan. January 2017 (has links)
Orientador: Rubens Nisie Tango / Coorientador: Alberto Noriyuki Kojima / Banca: Anelyse Arata / Banca: Eduardo Bresciani / Resumo: A literatura mostra escassez de informações sobre o envelhecimento de cerâmicas Y-TZP de uso odontológico, quando associado a escovação simulada. Sendo assim, o objetivo deste estudo foi avaliar o efeito da escovação simulada em algumas propriedades de zircônias estabilizadas por ítria (Y-TZP) após envelhecimento hidrotérmico. Foram confeccionados 36 discos da cerâmica (YZ®) - ISO 6872, 36 da cerâmica Cercon®Zirconia (DENTSPLY Ceramco, EUA) e 36 discos da cerâmica (Zirkon Transluzent - ICE Zirkonzahn®) os quais foram separados de acordo com o envelhecimento em reator hidrotérmico (controle e 6 horas de envelhecimento) e submissão à ciclagem de escovação simulada (controle e 72000 ciclos com carga de 350g e solução creme dental/água), resultando em 3 grupos de estudo, de acordo com o tipo de cerâmica utilizada para confecção da amostra e 4 Sub grupos, de acordo com a realização ou não do envelhecimento Hidrotérmico e escovação simulada nas amostras (n=9). Sendo YZ- Amostras realizadas com a cerâmica(YZ®);CZ- Amostras realizadas com a cerâmica-(Cercon®Zirconia);ZT- Amostras realizadas com a cerâmica (Zirkon Transluzent - ICE Zirkonzahn®).Teremos como subgrupos, 0- Grupo controle, amostras não submetidas nem ao envelhecimento, nem a escovação simulada; 1- Amostras submetidas apenas ao envelhecimento por 6 horas; 2- Amostras submetidas somente a escovação simulada; 3- Amostras submetidas ao envelhecimento hidrotérmico por 6 horas e escovação simulada. Os corpos de prova foram ava... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The literature shows a shortage of information about the aging of Y-TZP ceramics for dental use, when associated with simulated brushing. Therefore, the objective of this study was to evaluate the effect of simulated brushing on some properties of yttria stabilized zirconia (Y-TZP) after hydrothermal aging. Sixteen ceramic discs (YZ®) - ISO 6872, 36 Cercon®Zirconia ceramics (DENTSPLY Ceramco, USA) and 36 ceramic discs (Zirkon Transluzent - ICE Zirkonzahn®) were prepared, which were separated according to the aging in the reactor hydrothermal (control and 6 hours of aging) and submission to simulated brushing cycle (control and 72000 cycles with 350g load and toothpaste / water solution), resulting in 3 study groups, according to the type of ceramics used for cooking of the sample and 4 Sub groups, according to whether or not Hydrothermal aging and simulated brushing were performed in the samples (n = 9). (YZ®); CZ- Samples made with ceramics- (Cercon®Zirconia); ZT- Samples made with ceramics (Zirkon Transluzent - ICE Zirkonzahn®) .We will have as subgroups, 0- Control group, samples not submitted neither to aging nor simulated brushing; 1- Samples submitted only to aging for 6 hours; 2 - Samples submitted only to simulated brushing; 3 - Samples submitted to hydrothermal aging for 6 hours and simulated brushing. The specimens were evaluated by X-ray diffraction to verify T-M phase transformation and a sample of each group submitted to scanning electron microscopy (SEM) morphol... (Complete abstract click electronic access below) / Mestre
28

Influência da aplicação de selantes de superfície na rugosidade de resinas compostas / Surface sealant application influence on the resin composite roughness.

Nahsan, Flávia Pardo Salata 27 March 2009 (has links)
Este estudo avaliou, in vitro, a influência da aplicação de quatro selantes de superfície na rugosidade de duas resinas compostas. Cinqüenta espécimes foram confeccionados e divididos em 10 grupos com 5 espécimes cada, em função da combinação entre resina composta e selante de superfície, sendo: G1. Controle Concept; G2. Concept + Fortify; G3. Concept + Biscover; G4. Concept + Lasting Touch; G5. Concept + Fill Glaze; G6. Controle Esthet X; G7. Esthet X + Fortify; G8. Esthet X + Biscover; G9. Esthet X + Lasting Touch; G10. Esthet X + Fill Glaze. Os espécimes foram confeccionados com uma matriz específica, em quatro incrementos, com dimensões internas de 15mmX4mmX5mm, sendo sua polimerização realizada com o aparelho de lâmpada halógena Curing Light 2500 (500mW/cm2) por 20s cada incremento. Em seguida, foram armazenados em água destilada à 37ºC e umidade absoluta de 100% por 24 horas. Após este período, os espécimes foram adaptados em uma Politriz Metalográfica e planificados com lixas de granulometria 320, 600 e a rugosidade inicial foi aferida. Para a mensuração da rugosidade, utilizou-se o rugosímetro Hommel Tester T1000 basic. Numa segunda fase, aplicaram-se os selantes de superfície, conforme recomendações do fabricante, e uma nova aferição da rugosidade superficial foi realizada. Para o teste de abrasão, os espécimes foram submetidos a 100.000 ciclos de escovação, seguido de nova mensuração da rugosidade. Em adição à rugosidade e com o objetivo de avaliar qualitativamente a superfície de alguns espécimes, a leitura em Microscopia Eletrônica de Varredura foi empregada. Os resultados foram submetidos aos testes ANOVA a 3 critérios e Tukey para comparações individuais entre os diferentes grupos (p<0,05). A aplicação do selante de superfície diminuiu a rugosidade superficial das resinas compostas testadas (G2=0,0727, G3=0,0147, G4=0,0307, G5=0,0253, G6=0,0960, G7=0,0173, G8=0,0333, G9=0,0480). A abrasão simulada aumentou a rugosidade superficial para todos os grupos, com exceção do Fortify (G2=0,0740, G7=0,0673) e Biscover (G7=0,0440), sendo os maiores valores apresentados pelo Lasting Touch (G4= 0,1253, G9=0,0980), seguido do Fill Glaze (G5=0,0933, G10= 0,0847). / This in vitro study evaluated the influence of the application of four surface sealers on the surface roughness of composite resins. Fifty specimens were divided into ten groups according to different patterns of composite resin and surface sealers, as follows: G1. Control with Concept resin; G2. Concept + Fortify; G3. Concept + Biscover; G4. Concept + Lasting Touch; G5. Concept + Fill Glaze; G6. Control with Esthet X; G7. Esthet X + Fortify; G8. Esthet X + Biscover; G9. Esthet X + Lasting Touch; G10. Esthet X + Fill Glaze. Specimens were made in four increments using a stainless steel matrix of 15x5x4mm and resin increments were polymerized with halogen lamp Curing Light 2500 (500mW/cm2) for 20 seconds each. After complete polymerization, specimens were stored in 100% humidity in distilled water at 37ºC for 24 hours. Following storage, specimens were polished using ascending grades (320, 600) of abrasive SiC paper under running water and the initial roughness was measured with a perfilometer Hommel Tester T100 basic (Hommelwerke GmbH ref. # 240851 - Schwenningem - Germany). Surface sealers were applied following the manufacturer\'s instructions and a new measurement of roughness was made. For the abrasive resistance test, specimens were submitted to 100.000 cycles of abrasive dentifrice brushing followed by surface roughness.. Qualitative analisys was made by using MEV. Results were submitted to Three-way ANOVA (p<0,05) and Tuckey\'s test to individual comparisons between different groups. Surface sealant application provided smoother surfaces for of composite resins tested (G2=0.0727, G3=0.0147, G4=0.0307, G5=0.0253, G6=0.0960, G7=0.0173, G8=0.0333, G9=0.0480). The abrasion test increased the surface roughness for all tested groups, except Fortify (G2=0,0740, G7=0,0673) and Biscover (G7=0,0440). Lasting Touch presented rougher surfaces (G4= 0,1253, G9=0,0980), followed by Fill Glaze (G5=0,0933, G10= 0,0847).
29

Resistência à abrasão e à pigmentação extrínseca de resinas compostas tipo “bulk fill”

Lopes, Patrick Chaves 08 August 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2018. / Coordenação de Aperfeiçoamento Pessoal de Nível Superior (CAPES). / Este estudo in vitro teve como objetivos: (1) avaliar a rugosidade superficial promovida pela escovação simulada em resinas bulk fill de viscosidade regular, resinas bulk fill fluidas e resinas compostas convencionais; (2) avaliar a pigmentação extrínseca das resinas bulk fill de viscosidade regular, bulk fill fluidas e resinas compostas convencionais; e (3) avaliar se o repolimento das superfícies das resinas submetidas à pigmentação é capaz de devolver a cor próxima à inicial. 22 espécimes de cada resina (Filtek Z350 XT, Vittra APS, IPS Empress Direct, Filtek Bulk Fill, Opus Bulk Fill, Tetric N-Ceram Bulk Fill, Filtek Bulk Fill Flow, Opus Bulk Fill Flow e Surefil SDR Flow) foram confeccionados. Dez espécimes de cada resina sofreram abrasão superficial por escovação simulada (7.320 ciclos; 200g) e foram avaliados em rugosímetro (SJ-310 Mitutoyo). Outros dez espécimes foram submersos em café (7 dias, 37ºC), submetidos a fotografias padronizadas e mensuração de cor usando o sistema de cor CIELAB em três momentos diferentes: inicial, sete dias e pós repolimento. Dois espécimes de cada resina foram separados para análise das características morfológicas das partículas de carga das resinas em MEV. Os dados foram analisados estatisticamente pelos testes ANOVA e Tukey post hoc (α=0,05). Os valores de rugosidade (Ra) das resinas aumentaram após a escovação e houve diferença estatisticamente significativa entre as resinas. A rugosidade pós-escovação e a diferença de rugosidade (ΔRa) foram maiores nas resinas bulk fill fluidas, seguidas pelas resinas bulk fill de viscosidade regular e resinas compostas convencionais. Após o período de 7 dias de imersão no café, todas as resinas apresentaram pigmentação (ΔE ≥ 8). O repolimento reduziu os valores de ΔE para todas as resinas. A análise das partículas de carga por MEV mostrou variações morfológicas entre as resinas compostas. As resinas bulk fill fluidas sofreram mais desgaste superficial promovido pela escovação simulada, seguidas pelas resinas bulk fill de viscosidade regular e resinas compostas convencionais. Todas as resinas sofreram pigmentação e alteração de cor quando submetidas à imersão em café por 7 dias. O repolimento das superfícies das resinas submetidas à pigmentação foi capaz de remover parte dos pigmentos, mas não dentro do limite de aceitação estético. / The objectives of this in vitro study were: (1) to evaluate surface roughness promoted by simulated toothbrushing in bulk fill resins of regular viscosity, flowable bulk fill resins and conventional composite resins; (2) to evaluate extrinsic pigmentation of bulk fill resins of regular viscosity, flowable bulk fill resins and conventional composite resins; and (3) to evaluate if repolishing of resins subjected to pigmentation is able to return color close to initial. 22 specimens of each resin (Filtek Z350 XT, Vittra APS, IPS Empress Direct, Filtek Bulk Fill, Opus Bulk Fill, Tetric N-Ceram Bulk Fill, Filtek Bulk Fill Flow, Opus Bulk Fill Flow and Surefil SDR Flow) were made. Ten specimens of each resin had surface abrasive by simulated toothbrushing (7,320 cycles, 200g) and were evaluated by rugosimeter (SJ-310 Mitutoyo). Ten other specimens were submerged in coffee (7 days, 37ºC), submitted to standardized photographs and color measurement using the CIELAB color system at three different times: baseline, seven days and post-repolishing. Two specimens of each resin were separated for analysis of the morphological characteristics of filler particles in SEM. Data were analyzed statistically by ANOVA and Tukey post hoc tests (α=0.05). The surface roughness (Ra) of all resins increased after the brushing and there was statistically significant difference between them. Post-brush roughness and roughness difference (ΔRa) were higher in flowable bulk fill resins, followed by bulk fill resins of regular viscosity and conventional composite resins. After the 7-day immersion period in coffee, all resins presented pigmentation (ΔE ≥ 8). Repolishing reduced ΔE values for all resins. SEM analysis showed morphological variations among all composite resins. Flowable bulk fill resins suffered more surface wear promoted by simulated brushing, followed by bulk fill resins of regular viscosity and conventional composite resins. All resins underwent pigmentation and color change when submitted to immersion in coffee for 7 days. Repolishing the surface of resins subjected to pigmentation was able to remove some of the pigments, but not within the limit of aesthetic acceptance.
30

AVALIAÇÃO DAS ALTERAÇÕES NO ESMALTE APÓS APLICAÇÃO DE UM AGENTE CLAREADOR E ESCOVAÇÃO COM DENTIFRÍCIOS CLAREADORES / Evaluation of the alterations in enamel after application of a whitening agent and brushing with whitening toothpastes

Hilgenberg, Sérgio Paulo 25 February 2008 (has links)
Made available in DSpace on 2017-07-24T19:22:07Z (GMT). No. of bitstreams: 1 SergioPauloHilgenberg.pdf: 2684659 bytes, checksum: de5f3a51cd07ee516d316afe2e8f805b (MD5) Previous issue date: 2008-02-25 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to evaluate the physical-chemical and microbiology characteristics of 3 whitening toothpastes: Close-up Whitening - G1; Sorriso Branqueador - G2; Sensodyne Branqueador - G3, as well as, the action of the same ones on the dental enamel, when used alone or, after to the application of 16 carbamide peroxide. Firstly, they took place the physical-chemical and microbiologic analyses. Test chemical: Analysis of the pH: was dispersed 5g of toothpaste in 15mL of distilled water, after 24 hours the solution was analyzed in pHmeter. Physical tests: 1 – residue analysis: it was weighed 5g of toothpaste, submitted to the heating (105C/24h) and appraised the mass, after constant weight. 2 - Tenor of ashes: 2g of toothpaste were roasted (500C/30min). 3 - Analysis in MEV and EDX of the ashes. Test microbiologic: was used the kit Newplus, usually employed for microbiologic control of cosmetics. For the evaluation of the effect on the roughness of the enamel, were made 30 specimens, with three enamel segments (4 x 4 mm), obtained using a diamond disk. A perfilometer was used to determine the values of roughness average (Ra), total roughness (Rt) and Ry, initials and after the application of the bleaching agent and brushing with whitening toothpastes. The bleaching was accomplished in the surface of the fragments by 10 hours, and the brushing was accomplished in brushing machine. It was applied in one of the segments, after the bleaching agent, topical fluoride. Significant differences was found in the physiochemical parameters (p <0.05 - ANOVA, pos-test of Bonferroni). pH Test: G1=7.9±0.1; G2=10.1±0.1 and G3=9.1±0.1. Residue analysis: G1=44.7±1.1, G2=65.8±2.2 and G3=39.9±1.1. Tenor of ashes: G1=17.6±1.2, G2=36.6±2.0 and G3=16.0±3.1. The EDX test found chemical elements indicated by manufacturers in the formulation. The SEM demonstrated differences in the morphology of the abrasives. The microbiological test no detected bacterial or fungus contamination. The data initials and final of the three roughness parameters (Ra, Rt and Ry) were submitted to the t-Student test, that demonstrated there to be differences among the applied treatments to the enamel and the interaction with the toothpaste: for G1 - all of the roughness parameters were altered when the brushing was preceded of bleaching agent and, for G2, the use of the toothpaste on the enamel, altered the parameter of roughness average. It was concluded that differences exist in the physical-chemical properties of the tested toothpastes (solid residue, tenor of ashes and pH) taking to different abrasive potential and possibly to different therapeutic functions; there was not microbial contamination in any analyzed toothpaste, demonstrating a good quality control in the production of the same ones; differences exist in the morphology and composition in the abrasive agents of the studied toothpastes, taking to different abrasive potential; the parameter of roughness average was just altered for when Sorriso Branqueador was used on the dental enamel; the use of bleaching agent previously to the brushing with abrasive toothpaste was factor that determined alteration in the three roughness parameters for the group Close-up Whitening and, use of topical fluoride for one minute after the exhibition to bleaching agents went effective to avoid alteration in the roughness parameters in the group Close-up Whitening. / O objetivo deste trabalho foi avaliar as características físico-químicas e microbiológicas de 3 dentifrícios clareadores: Close-Up Whitening- G1; Sorriso Branqueador- G2; Sensodyne Branqueador- G3, como também, a ação dos mesmos sobre o esmalte dental, quando utilizados sozinhos ou, posteriormente à aplicação de peróxido de carbamida 16. Primeiramente, realizaram-se as análises físicoquímicas e microbiológicas. Teste químico: Análise do pH: dispersou-se 5g de dentifrício em 15mL de água destilada, após 24h a solução foi analisada em pHmetro. Testes físicos: 1- Perda por dessecação: foi pesado 5g de dentifrício, submetido ao aquecimento (105C/24h) e avaliada a massa, após peso constante. 2-Teor de cinzas: 2g de dentifrício foram calcinados (500C/30min). 3- Análise em MEV e EDX das cinzas. Teste microbiológico: uso do kit Newplus, empregado para controle microbiológico de cosméticos. Para a avaliação do efeito sobre a rugosidade do esmalte, foram confeccionados 30 corpos-de-prova, com três segmentos de esmalte (4 x 4 mm), obtidos por meio de seccionamento com disco diamantado. Um rugosímetro foi utilizado para determinar os valores de rugosidade média (Ra), rugosidade total (Rt) e Ry, iniciais e após a aplicação do agente clareador e escovação com dentifrícios clareadores. O clareamento foi realizado na superfície dos fragmentos por 10 horas, e a escovação foi realizada em máquina de escovação. Foi aplicado em um dos segmentos, após o agente clareador, flúor tópico, afim de observar o efeito protetor do mesmo. Encontraram-se diferenças significativas nos parâmetros físico-químicos avaliados (p0,05 – ANOVA, pós teste de Bonferroni). Teste de pH: G1=7,9±0,1; G2=10,1±0,1 e G3=9,1±0,1. Perda por dessecação: G1=44,7±1,1, G2=65,8±2,2 e G3=39,9±1,1. Teor de cinzas: G1=17,6±1,2, 2=36,6±2,0 e G3=16,0±3,1. EDX encontrou os elementos químicos indicados pelos fabricantes na formulação. MEV demonstrou diferenças na morfologia dos abrasivos. O teste microbiológico não detectou contaminação bacteriana ou fúngica. Os dados iniciais e finais dos três parâmetros de rugosidade (Ra, Rt e Ry) foram submetidos ao teste t-Student pareado, que demonstrou haver diferenças entre os tratamentos aplicados ao esmalte e a interação com o dentifrício: para G1 – todos os parâmetros de rugosidade foram alterados quando a escovação foi precedida de agente clareador e, para G2, o uso do dentifrício sobre o esmalte, alterou o parâmetro de rugosidade média. Desta forma conclui-se que existem diferenças nas propriedades físico-químicas dos dentifrícios testados (resíduo sólido, teor de cinzas e pH) levando a potencial abrasivo distinto e possivelmente a funções terapêuticas diferentes; não houve contaminação microbiana em nenhum dentifrício analisado, demonstrando um bom controle de qualidade na fabricação dos mesmos; existem diferenças na morfologia e composição nos agentes abrasivos dos dentifrícios estudados, levando a potencial abrasivo distinto; o parâmetro de rugosidade média foi alterado apenas para o uso do dentifrício Sorriso Branqueador sobre o esmalte dental; o uso de agente clareador previamente à escovação com dentifrício abrasivo foi fator que determinou alteração nos três parâmetros de rugosidade para o grupo Close-Up Whitening e, uso de flúor tópico por um minuto após a exposição a agentes clareadores foi efetivo para evitar alteração nos parâmetros de rugosidade no grupo Close-Up Whitening.

Page generated in 0.4769 seconds