• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 192
  • 1
  • Tagged with
  • 194
  • 194
  • 108
  • 95
  • 95
  • 72
  • 68
  • 59
  • 49
  • 47
  • 40
  • 40
  • 35
  • 31
  • 28
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Avaliação da remoção de nitrogênio e fósforo em banhados construídos para o tratamento combinado de esgoto sanitário e lixiviado de aterro sanitário estabilizado

Ospitia Thola, Beatriz Eugenia January 2015 (has links)
O lixiviado, líquido complexo gerado nos aterros sanitários e depósitos de lixo a céu aberto, apresenta características de um poluidor em potencial, de difícil tratamento, devido a processos físico-químicos e de decomposição biológica dos resíduos sólidos no aterro sanitário, somado à infiltração de água de chuva. Formas de atenuar e tratar esse tipo de efluente vão desde tratamentos biológicos até técnicas avançadas de oxidação, sendo estes últimos de alto custo em sua infraestrutura, operação e manutenção. Uma alternativa adotada nos últimos tempos por muitas cidades de Brasil e o mundo inteiro é o tratamento combinado de lixiviado de aterro sanitário com esgoto sanitário, por ter vantagens custo-benefício viáveis. Na presente pesquisa foi avaliada a remoção de nutrientes, como nitrogênio e fósforo, em três sistemas de banhados construídos em escala piloto operados em paralelo (sistemas B1, B2, e B3), sendo cada um deles composto por duas unidades em série de fluxo vertical seguidos por duas unidades em série de fluxo horizontal de escoamento subsuperficial, plantados com macrófitas emergentes L. Peruviana e Typha sp., respectivamente, para tratar a combinação de 10 % de lixiviado de aterro sanitário estabilizado com 90 % de esgoto sanitário afluente à ETE Canoas, com tratamento prévio (B1: UASB+CBR e B2: UASB) e sem tratamento prévio (B3: esgoto bruto/lixiviado), com taxa de aplicação superficial de 400L/m2.dia e aplicação em bateladas com períodos de aproximadamente 15 minutos. O estudo foi desenvolvido na estação climática de inverno da região Sul do Brasil, no qual a remoção média de amônio (N-NH4+) foi maior que 95 % nos três banhados não sendo observada diferença significativa para p> 0,05, entre eles, enquanto que a remoção de nitrato (NO3-) foi provavelmente limitada pela baixa relação carbono/nitrogênio (C/N). O fósforo total (PT) apresentou remoções maiores que 45 % nos três sistemas sem diferença significativa, porém foi observada diferença significativa para a remoção de ortofosfato (P-PO4-) (p> 0,05) no banhado B3, quando este mostrou remoção negativa. A remoção de N e P pela absorção das plantas (L. Peruviana e Typha sp.) foi de aproximadamente 1 % e 2 % respectivamente, comparado com a remoção destes nutrientes na fase líquida. A precipitação e evapotranspiração não apresentaram influência na remoção de nutrientes. / The leachate, complex liquid generated in landfills and open dumps, has characteristics of a potential polluter, difficult to treat due to physical and chemical processes and biological decomposition of solid waste in landfills, added to rainwater infiltration. Ways to mitigate and treat this type of effluent range from biological treatments to advanced oxidation techniques, the latter being of high cost in its infrastructure, operation and maintenance. An alternative adopted recently by many cities of Brazil and the whole world is the combined treatment of landfill leachate with sanitary sewer, having advantages viable cost-effective. In the present study the removal of nutrients such as nitrogen and phosphorus were evaluated, in three pilot scale constructed wetlands systems, operated in parallel, (systems B1, B2 and B3) consisting each one of two vertical flow units in series followed by two horizontal flow units of subsurface flow, planted with emerging macrophytes L. peruviana and Typha sp., respectively, to treat the combination of 10% of stabilized landfill leachate with 90% of urban raw wastewater from ETE Canoas, with previous treatment (B1: UASB+CBR and B2: UASB) and untreated (B3: raw sewage / leachate), with superficial application rate of 400 L / m2.day, fed in batch periods of approximately 15 minutes. The study was conducted during the winter season in the southern region of Brazil, in which the average removal of ammonium (N-NH4+) was higher than 95 % in the three systems without significant difference among them (p> 0.001) and the removal of nitrate (NO3-) was probably limited by the low ratio carbon / nitrogen (C / N). The total phosphorus (PT) removal was greater than 45 % without significant difference among the three systems however a significant difference was observed for orthophosphate (P-PO4-) (p> 0.05) removal at B3 system, when it showed a negative removal. The nitrogen and phosphorous removal due to the absorption by the plants (L. peruviana and Typha sp.) was approximately 1 % and 2 % respectively, compared to the removal of the nutrients in the liquid phase. The precipitation and evapotranspiration did not caused influence upon the nutrients removal.
172

Modelagem empírica para ajuste, correção e análise de confiabilidade de parâmetros de reatores UASB /

Serra, Antonio Marcos Galvez January 2019 (has links)
Orientador: Rodrigo Braga Moruzzi / Resumo: A falha humana é um evento indesejado para os engenheiros, e a população que se vê refém destes empreendimentos, (visto os diversos incidentes que ocorrem no Brasil) por fatores como omissão de informações, medições equivocadas ou mesmo erros técnicos, passam despercebidos durante as vistorias. Na área de Saneamento, em se tratando de esgoto sanitário, os riscos não são menores e também devem ser evitados considerando o número de doenças que são proliferadas por falhas no saneamento de esgoto. A partir deste pressuposto, a presente pesquisa visou desenvolver um modelo preditor, usando ferramentas matemáticas que viabilizassem identificar e corrigir erros técnicos no registro e medições realizadas em parâmetros físicos, químicos e biológicos de dois reatores UASB da Estação Candeia da cidade de Bauru- SP. Para isto, após uma revisão sobre a tecnologia de reatores UASB e de estudos probabilísticos baseados no conceito de confiabilidade aplicado a ETEs (Estações de Tratamento de Esgotos), definiu-se, por meio de análise de regressão, um modelo multilinear, acoplado a um algoritmo de otimização, capaz de prever e corrigir parâmetros de entrada e saídas (inconsistentes ou ausentes) no registro do monitoramento da estação referentes ao tratamento de reatores UASB. Com este procedimento matemático, através de uma análise estatística conceitual de confiabilidade do sistema, foi possível corrigir dados e estimar informações de parâmetros ausentes, em 22% das coletas de medidas e regis... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Human failure is an unwanted event for engineers, and the population that is hostage to these endeavors, (due to the various incidents that occur in Brazil) due to factors such as omission of information, wrong measurements or even technical errors, go unnoticed during surveys. . In the Sanitation area, when it comes to sanitary sewage, the risks are no less and should also be avoided considering the number of diseases that are proliferated by sewage sanitation failures. From this assumption, the present research aimed to develop a predictor model, using mathematical tools that could identify and correct technical errors in the recording and measurements performed on physical, chemical and biological parameters of two UASB reactors at Candeia Station of Bauru- SP. For this, after a review of UASB reactor technology and probabilistic studies based on the concept of reliability applied to sewage treatment plants (SEP), a multilinear model coupled to a optimization algorithm, capable of predicting and correcting input and output parameters (inconsistent or absent) in the station monitoring register for the treatment of UASB reactors. With this mathematical procedure, through a conceptual statistical analysis of system reliability, it was possible to correct data and estimate missing parameter information in 22% of the measurement collections and records in the technical reports that were made available for this study. / Mestre
173

Estação de tratamento de esgotos: uma análise da correlação entre a aeração e a emissão de óxido nitroso / Sewage treatment plant: an analysis of the correlation between the aeration and the emission of nitrous oxide

Piccoli, Andrezza de Souza January 2010 (has links)
Made available in DSpace on 2011-05-04T12:36:15Z (GMT). No. of bitstreams: 0 Previous issue date: 2010 / Em inúmeras ações humanas ocorrem emissões de gases que podem contribuir sobre maneira para o aumento na concentração dos gases estufa, dentre eles o óxido nitroso, acarretando danos ambientais locais e globais. Na busca de contribuir para o entendimento das causas para as mudanças climáticas globais há necessidade de compreender e conhecer os fluxos de óxido nitroso emitidos por diversos setores da atividade humana, inclusive em Estações de Tratamento de Esgoto. Aliando à técnica aspectos ambientais importantes a serem considerados no planejamento para implantação de uma tecnologia de tratamento de esgotos e proporcionando uma integração de campos de conhecimento, o estudo tem como objetivo analisar a correlação entre a aeração e a emissão de óxido nitroso em sistema de tratamento de esgotos. Tendo como metodologia o estudo de caso em Estação de Tratamento de Esgotos na Região Serrana do Estado do RJ, a pesquisa é caracterizada como pesquisa bibliográfica documental, exploratória e descritiva, com análises realizadas em laboratório. Este estudo é original em países tropicais, sendo o único estudo anterior feito na Universidade de New Hampshire / EUA em 1995. Visa, portanto, contribuir com a atualização de dados referentes às Mudanças Climáticas, possibilitando o aprofundamento futuro do tema. / In many human actions occurring gas emissions that can contribute significantly to the increased concentration of greenhouse gases, among them the oxide, causing environmental damage locally and globally. In seeking to contribute to the understanding of the causes of global climate change need to know and understand the flow of nitrous oxide emitted by various sectors of human activity, including waste treatment stations. Combining the technical environmental aspects to be considered in planning for deployment of a technology for treating wastewater and providing an integration of fields of knowledge, the study aims to analyze the correlation between the aeration and the emission of nitrous oxide system in wastewater treatment. Since the methodology as a case study in Station Sewage Treatment in the mountainous region of the state of RJ, the search is characterized as documentary literature, exploratory and descriptive, with analysis performed in the laboratory. This study is unique in tropical countries, the only previous study of the University of New Hampshire / USA in 1995. Aim, therefore contribute to the updating of data to climate change, enabling the further development of the theme.
174

Remoção de DQO e de nitrogênio, e estudo dos consórcios microbianos em sistema com três reatores sobrepostos, em série, alimentado com esgoto sanitário / COD and nitrogen removal, and microbial associations study on a three superposed, in series, reactors system, fed with domestic wastewater

Santos, Pedro Ivo de Almeida 17 December 2004 (has links)
Esta pesquisa enfoca a avaliação do desempenho de nova configuração de unidade para tratamento biológico de esgoto sanitário por processo combinado, visando à remoção de nutrientes, especialmente nitrogênio. O sistema construído em escala piloto tem volume útil igual a 71,48 litros. Nesta nova configuração de reatores para tratamento terciário de esgoto sanitário, utilizaram-se três reatores sobrepostos, sendo: um reator UASB - “Upflow Anaerobic Sludge Blanket"; um reator de leito móvel e filme fixo aeróbio (com aplicação de oxigênio puro); e, um reator de leito móvel e filme fixo com ambiente anóxico. O material suporte utilizado nos reatores de leito móvel e filme fixo constituiu alternativa inédita no tratamento de efluentes líquidos. Foram utilizadas cavilhas “ranhuradas" de madeira, de dimensões aproximadas de 8,0 mm de diâmetro por 8,0 mm de comprimento. O desempenho geral do sistema quanto à remoção de matéria carbonácea e compostos nitrogenados, e as associações microbianas formadas nos três reatores são objetos principais de estudo deste trabalho. Foram obtidos resultados de remoção de DQO e de nitrogênio bastante satisfatórios, sobretudo quando o tempo de detenção hidráulica total esteve próximo a 20 horas, incluindo o compartimento de decantação (94,6 % para DQO; e 96,7 % para N-NTK, com formação de nitrato em concentrações inferiores a 10,0 mgN-NO3-/l). O TDH estudado variou entre 5 e 24 horas para os sistema completo. O estudo dos consórcios de microrganismos forneceu excelentes resultados quanto à quantidade, diversidade, e atividade das populações desenvolvidas nos diferentes ambientes, confirmando o bom desempenho do sistema e o fornecimento de ambiente adequado para o desenvolvimento das diferentes populações nos três reatores. A idealização desta configuração tem como finalidade realização de tratamento de esgoto sanitário até nível terciário em planta compacta, podendo ser utilizada por pequenas e grandes comunidades, devido à possibilidade de se construir diversos módulos do sistema proposto. / This research is focused on the performance evaluation of a new system configuration of combined biological reactors, treating domestic wastewater till tertiary level. The pilot scale proposed system had a total useful volume of 71,48 liters. This new configuration involves three types of superposed reactors: an Upflow Anaerobic Sludge Blanket reactor; an aerobic fixed film mobile bed reactor (fed with pure oxygen); and a fixed film mobile bed reactor at anoxic environment. The support material used inside the fixed film mobile bed reactors was wood made grooved dowels. The main purposes of this work are to evaluate the systems general performance regarding COD and nitrogen removal, and the microbial associations inside the reactors. It reached quite satisfactory results regarding COD and nitrogen removal when the total hydraulic retention time (HRT) was around 20 hours, including the clarification zone volume (94,6 % for the COD; and 96,7 % for the TKN-N, whit nitrate formation below 10,0 mgN-NO3-/l). HRTs from 5 to 20 hours were studied. The microbial associations were present in large number, with a great diversity and high specific activities at the different environments, confirming the good results obtained and the suitable environment provided for the growth of the different populations inside the three reactors. The idealization of this treatment system has the goal to treat domestic wastewater from small to large communities till tertiary level, in compact treatment plants, due to the possibility of constructing several modules of the system.
175

Avaliação da remoção de Giardia spp. e Cryptosporidium spp. em processos de tratamento de esgoto sanitário / Assessment of removal of Giardia spp. and Cryptosporidium spp. from wastewater treatment processes

Medeiros, Raphael Corrêa 27 September 2013 (has links)
Este trabalho teve o intuito de avaliar a eficiência de remoção de protozoários patogênicos - Giardia spp. e Cryptosporidium spp. - em processos de tratamento de esgoto sanitário por reator UASB, lodos ativados, filtro lento em areia e diferentes desinfetantes. A recuperação de cistos de Giardia e de oocistos de Cryptosporidium, realizada por diferentes metodologias e utilizando ColorSeed®, foi de, respectivamente, 85 e 20% em esgoto bruto, e 62,5 e 17,5% em efluente tratado, quando foi utilizado o método de tripla centrifugação. Cistos de Giardia foram encontrados em 100% as amostras de esgoto pesquisadas, com média de 1,5 x 104 cistos por litro e oocistos de Cryptosporidium em 31,4% com média 3,1 x 10² oocistos por litro, em esgoto bruto. No tratamento biológico por reator UASB seguido de Lodos Ativados, a remoção de cisto de Giardia e esporos de Clostridium perfringens foram estatisticamente menores que as remoções de E. coli e coliformes totais. Não foram encontrados (oo)cistos após o tratamento terciário realizado através da filtração lenta em areia. Houve remoção estatisticamente maior na ETE em escala plena para coliformes totais e Clostridium perfringens. E. coli e cistos de Giardia, em ambas ETEs, apresentaram remoções similares. Elevadas concentrações de (oo)cistos foram encontradas no lodo de esgoto, com grande porcentagem ainda viável. Com relação à desinfecção, entre as bactérias indicadoras, Clostridium perfringens foram mais resistentes ao cloro, ozônio e radiação ultravioleta. O efeito sinérgico, promovido pelas desinfecções sequenciais (clororadiação ultravioleta e ozônio-radiação ultravioleta), foi evidenciado em alguns experimentos para todas as bactérias estudadas. O cloro alterou a fluorescência dos cistos de Giardia e o ozônio, além de alterar a fluorescência, foi capaz de diminuir a concentração de cistos desse microrganismo. Pode-se concluir que as concentrações tanto de microrganismos indicadores como de protozoários patogênicos é bastante elevada, qualquer que seja o tipo de esgoto: bruto, efluente do reator UASB ou efluente do lodos ativados. Isso evidencia o extremo cuidado com que estes efluentes devem ser tratados, para posteriores usos ou lançamento em corpo receptor, em especial devido à presença de (oo)cistos ainda viáveis de Giardia spp. e Cryptosporidium spp. mesmo após o tratamento biológico por lodos ativados, e a necessidade de desinfecção do efluente. / This work aimed to evaluate the efficiency of removal of pathogenic protozoa - Giardia spp. and Cryptosporidium spp. - during wastewater treatment by UASB reactor, activated sludge, slow sand filter and different disinfectants. The recovery of Giardia cysts and of Cryptosporidium oocysts, performed by different methodologies and using ColorSeed®, was respectively of 85 and 20%, in raw wastewater and 62.5 and 17.5% in treated effluent, applying triple centrifugation method. Giardia cysts were found in 100% of the the sewage samples surveyed, with average of 1.5 x 104 cysts per liter and Cryptosporidium oocysts were found in 31.4% with average of 3.1 x 10² oocysts per liter, in raw wastewater. Giardia cyst and Clostridium perfringens spores removals were statistically lower than E. coli and total coliforms removal when applying the biological treatment by UASB reactor followed by Activated Sludge. There were no (oo) cysts after treatment tertiary accomplished by slow sand filtration. There was a statistically higher removal in the full scale WWTP for total coliforms and Clostridium perfringens; however, E. coli and Giardia cysts, in both WWTPs, presented the same removal efficiency. High concentrations of (oo)cysts were found in the sludge sludge, with a high percentage still viable. Regarding disinfection, among the indicating bacteria, Clostridium perfringens was more resistant to chlorine, ozone and ultraviolet radiation. The synergic effect promoted by sequential disinfections (chlorine-ultraviolet radiation and ozone-ultraviolet radiation) was evidenced in some experiments for all the bacteria studied. Chlorine altered the fluorescence of Giardia cysts and ozone, as well as change in fluorescence was able to decrease the concentration of this microorganism. It can be concluded that the concentrations of indicator microorganisms as well as of pathogenic protozoa is very high, regardless the kind of wastewater: raw, UASB reactor effluent or activated sludge effluent. This shows the extreme care that must be taken towards these effluents, for future reuse or simply release in the environment, mainly due to the presence of viable Giardia spp. and Cryptosporidium spp. (oo)cysts even after the activated sludge treatment, and the need of disinfection of the effluent.
176

Avaliação da recirculação da fase líquida e do regime de alimentação no reator anaeróbio, em escala piloto, operado em bateladas seqüenciais contendo biomassa imobilizada (ASBBR), no tratamento de esgoto sanitário / Influence of the liquid phase recirculation and the feeding regimen on a pilot anaerobic immobilized biomass sequencing batch reactor treating domestic sewage

Lapa, Katt Regina 19 December 2006 (has links)
Avaliou-se a influência da recirculação da fase líquida e do regime de alimentação em reator anaeróbio no tratamento de esgoto sanitário. Utilizou-se um reator anaeróbio operado em bateladas seqüenciais, contendo biomassa imobilizada (ASBBR), em escala piloto, com volume total de 1,2 \'M POT.3\' (\'fi\' 1,0 m e altura 1,53 m). O leito suporte para a imobilização da biomassa era constituído por matrizes cúbicas de espuma de poliuretano, com 5 cm de aresta, confinadas em cesto de aço inox 304, colocado no interior do reator. A influência da recirculação da fase líquida sobre o desempenho do ASBBR quanto à remoção de matéria orgânica e quanto ao arraste de sólidos foi avaliada submetendo-se o reator às velocidades ascensionais de 1,27; 3,82; 7,64 e 10,18 m/h resultantes das diferentes vazões de recirculação impostas. Contrariamente ao observado em pesquisas anteriores em reatores operados em escala de bancada e alimentados com água residuária sintética, não houve aumento significativo da eficiência do reator com o aumento da velocidade ascensional no tratamento de esgoto sanitário. A influência do regime de alimentação de esgoto sanitário no desempenho do ASBBR foi avaliada submetendo-se o reator a tempos de enchimento correspondentes a 0,25 e 0,5 do tempo total de ciclo, utilizando-se a vazão de recirculação de 6 \'M POT.3\'/h, que foi a que apresentou os melhores resultados nos ensaios anteriores. Concluiu-se que o reator pode ser operado sob batelada alimentada com duração de até 0,5 tempo de ciclo, sem que seu desempenho seja significativamente alterado. Esse resultado é importante, pois representa que o sistema de tratamento composto por reatores ASBBR pode ser projetado com número menor de reatores. A fim de esclarecer dúvidas sobre o desempenho do ASBBR observado no tratamento de água residuária de composição complexa (esgoto sanitário), o reator foi alimentado com água residuária facilmente degradável (etanol). O desempenho do reator foi aquém do esperado, mesmo quando alimentado com composto de fácil degradação. Os ensaios de atividade metanogênica específica (AME) demonstraram que houve decréscimo dos valores de AME com o aumento da velocidade ascensional. Os valores obtidos foram 0,0632; 0,0509; 0,0248 e 0,0299 g DQO-CH4/(g STV.d), respectivamente, para os valores de Va de 1,27; 3,82; 7,64 e 10,19 m/h. Concluiu-se que a baixa eficiência de remoção de matéria orgânica deveu-se ao abaixamento progressivo da atividade metanogênica do lodo, cujas causas não puderam ser completamente esclarecidas nesta pesquisa. / The influence of the liquid phase recirculation and the feeding regimen on the performance of an anaerobic sequencing batch reactor containing immobilized biomass (ASBBR) applied for the treatment of domestic sewage was evaluated. Biomass immobilization was provided by a basket containing cubic polyurethane foam matrices (5 cm side) inside the 1.2 \'M POT.3\' (1.0 m diameter and 1.53 m height) pilot-scale reactor. The influence of the liquid phase recirculation on the reactor performance in respect to organic matter and solids wash-out was verified by subjecting the reactor to a wide range of up flow velocities (1.27; 3.82; 7.64 and 10.18 m/h) resulting from different recirculation flow rates imposed. The increase of the up flow velocity did not increase the efficiency of the pilot reactor as expected. This result contradicts those obtained with bench-scale ASBBR experiments treating synthetic wastewaters. The influence of the feeding regimen was verified by subjecting the reactor to feeding times correspondent to 0.25 and 0.50 of the total cycle time, at the recirculation flow rate of 6 \'M POT.3\'/h. It could be concluded that the reactor can be operated at the feeding batch mode up to 0.5 of the cycle time. This result is important for full scale applications considering that a treatment system composed of ASBBR reactors can be designed using a lower number of units. In order to clear some aspects related to the limited performance of the ASBBR reactor treating a complex wastewater (sewage), the reactor was subjected to an easily degradable wastewater (ethanol). However, the performance was not improved even when the reactor was treating an easily degradable compound. The results from the specific methanogenic activity (SMA) demonstrated a decrease on the values of SMA with the increase of the up flow velocity. The values of SMA were 0.0632; 0.0509; 0.0248 and 0.0299 g DQO-CH4/(g STV.d) for the Va of 1.27; 3.82; 7.64 and 10.19 m/h respectively. It could be concluded that the low efficiency obtained for organic matter removal was due mainly to the progressive decrease of the sludge methanogenic activity. The causes for that behaviour could not be completely explained in this research. It could be concluded that the reactor performance was iv clearly limited by the low productivity of the methanogenic populations present in the biomass.
177

Emprego de coagulante à base de tanino em sistema de pós-tratamento de efluente de reator UASB por flotação / Use of tannin-based coagulant in exhaust post-treatment of UASB reactor effluent by flotation

Pelegrino, Eloá Cristina Figueirinha 03 June 2011 (has links)
O presente trabalho teve como objetivo principal a avaliação da eficiência de remoção de carga orgânica, fósforo e sólidos em suspensão de sistema de flotação tratando esgoto sanitário pré-tratado em reatores UASB, da ETE Monjolinho da cidade de São Carlos/SP, e coagulado com tanino associado ou não a polímeros sintéticos. Os ensaios com variação de dosagem de coagulante Tanino e polímeros (polímero catiônico, polímero não-iônico e polímero aniônico) foram realizados em escala de laboratório, com o uso do equipamento flotateste. Em todos os ensaios foram fixados os valores de gradiente de velocidade na mistura rápida (800/s) e na floculação (90/s), ao tempos de detenção na mistura rápida (20 s) e na floculação (15 min) e, a pressão de saturação 5 Bar e a razão de recirculação (17%). Durante os ensaios com unidade de flotação em escala de bancada foram avaliados três valores de velocidades de flotação: 12,0 cm/min, 16,0 cm/min e 20,0 cm/min. Os ensaios foram divididos em duas fases: a fase 1 teve como objetivo analisar a resposta do sistema de flotação com o emprego do coagulante Tanino no tratamento do efluente do reator UASB da ETE Monjolinho (fase 1A) e também determinar as duas dosagens do coagulante Tanino mais adequadas para o tratamento do efluente de UASB da ETE Monjolinho para cada polímero testado (fase 1B). As fases 1A e 1B foram realizadas com efluente coletado às 8:00 h e 14:00 h, respectivamente. A fase 2 teve como objetivo a busca da dosagem ótima de tanino dentro de uma faixa mais estreita de valores, assim como a verificação do melhor tipo e dosagem de polímero sintético (não-iônico, aniônico e catiônico) para ser associado ao coagulante tanino. Na fase 1A, verificou-se que a flotação foi efetiva para remoção de cor aparente mesmo para dosagem nula de coagulante Tanino. Quanto à turbidez, verificou-se efeito marcante da adição de dosagem crescente de coagulante no aumento da eficiência de remoção desse parâmetro. Após a obtenção dos resultados da fase 1B, foram escolhidas para a fase 2 as duas menores dosagens de coagulante capazes de promover redução da turbidez em pelo menos 85%. Além destas duas dosagens, foram avaliados na fase 2 outras 3 dosagens compreendidas entre elas. Sendo assim, na fase 2 foram estudadas as doses de 65, 75, 85, 95 e 105 mg/L de coagulante, cada qual associada a seis dosagens de cada um dos polímeros estudados. Entre os tratamentos empregados, pôde-se verificar maior eficácia do polímero não-iônico e do polímero catiônico para o tratamento por flotação, associado ao coagulante tanino. O conjunto de dosagem de coagulante tanino e polímero mais vantajoso, ou seja, menor dosagem de tanino que, associada a polímero, apresentou remoção satisfatória dos parâmetros estudados, foi 65 mg/L de Tanino e 2,0 mg/L de polímero catiônico, atingindo remoções de 95,2% de turbidez (Residual de 3,65 NTU), 82,1% de cor aparente (Residual de 98 mgPT/L), 49,2% de fósforo total (Residual de 3,2 mg/L), 80,7% de DQO (Residual de 25 mg/L) e 87,9 % de SST (Residual de 13 mg/L) nas condições encontradas na época dos ensaios, para o pós-tratamento por flotação de efluente de reator UASB da ETE Monjolinho, São Carlos/SP. / The main objective of this work is the evaluation of the efficiency of removal of organic load, phosphorus and suspended solids in the flotation system treating domestic wastewater pretreated in UASB reactors, of the Monjolinho Wastewater Treatment Plant (WWTP) of Sao Carlos, SP and clotted with tannin alone or combined with synthetic polymers. Tests varying tannin dosage of coagulant and polymer (cationic polymer, nonionic polymer and anionic polymer) were performed on a batch scale, using flotatest. In all the tests were fixed the values of rapid mix (800/s) and flocculation (90/s) velocity gradients, the rapid mix (20 s) and flocculation (15 min) times, saturation pressure (5 Bar) and recycle rate (17%). During the test in the flotation bench scale unity three values of flotation velocities were evaluated: 12.0 cm/min, 16.0 cm/min and 20.0 cm/min. The tests were divided in two phases: the objective of phase 1 was to examine the response of the flotation system with the use of tannin coagulant in the treatment of Monjolinho WWTP UASB effluent (Phase 1A) and also determine the two most suitable dosages of tannin coagulant for the treatment of wastewater from the Monjolinho WWTP UASB tested for each polymer (phase 1B). Phases 1A and 1B were performed with wastewater collected at 8:00 h and 14:00 h, respectively. The objective of phase 2 was to find the optimum dosage of tannin within a narrower range of values, as well as verification of the optimal type and dosage of synthetic polymer (non-ionic, anionic and cationic) to be associated with the tannin coagulant. In phase 1A, it was found that flotation was effective for apparent color removal even to zero coagulant dosage tannin. As for turbidity, there is a marked effect when increasing the coagulant dose, which increased the removal efficiency of this parameter. After obtaining the results of Phase 1B, were chosen for phase 2 two low coagulant dosages which can promote reduction of turbidity by 85%. Besides the two dosages obtained in phase 1B, in phase 2 were evaluated other three between them. Thus, in phase 2 were studied coagulant doses of 65, 75, 85, 95 and 105 mg/L, each one associated with six doses of each one of the studied polymers. Among the treatments employed, it could be seen that the non-ionic polymer and the cationic polymer were the most efficient for treatment by coagulation associated with tannin in flotation. The set of tannin coagulant dosage and polymer which showed satisfactory removal of parameters was 65 mg/L of Tannin with 2.0 mg/L of cationic polymer, reaching 95.2% removal of turbidity, 83% of color apparent, 49.2% of total phosphorus, COD 80.7% and 87.9% of TSS under the conditions found at the time of testing, for post-treatment of Monjolinho WWTP UASB effluent by flotation.
178

Avaliação da remoção de Giardia spp. e Cryptosporidium spp. em processos de tratamento de esgoto sanitário / Assessment of removal of Giardia spp. and Cryptosporidium spp. from wastewater treatment processes

Raphael Corrêa Medeiros 27 September 2013 (has links)
Este trabalho teve o intuito de avaliar a eficiência de remoção de protozoários patogênicos - Giardia spp. e Cryptosporidium spp. - em processos de tratamento de esgoto sanitário por reator UASB, lodos ativados, filtro lento em areia e diferentes desinfetantes. A recuperação de cistos de Giardia e de oocistos de Cryptosporidium, realizada por diferentes metodologias e utilizando ColorSeed®, foi de, respectivamente, 85 e 20% em esgoto bruto, e 62,5 e 17,5% em efluente tratado, quando foi utilizado o método de tripla centrifugação. Cistos de Giardia foram encontrados em 100% as amostras de esgoto pesquisadas, com média de 1,5 x 104 cistos por litro e oocistos de Cryptosporidium em 31,4% com média 3,1 x 10² oocistos por litro, em esgoto bruto. No tratamento biológico por reator UASB seguido de Lodos Ativados, a remoção de cisto de Giardia e esporos de Clostridium perfringens foram estatisticamente menores que as remoções de E. coli e coliformes totais. Não foram encontrados (oo)cistos após o tratamento terciário realizado através da filtração lenta em areia. Houve remoção estatisticamente maior na ETE em escala plena para coliformes totais e Clostridium perfringens. E. coli e cistos de Giardia, em ambas ETEs, apresentaram remoções similares. Elevadas concentrações de (oo)cistos foram encontradas no lodo de esgoto, com grande porcentagem ainda viável. Com relação à desinfecção, entre as bactérias indicadoras, Clostridium perfringens foram mais resistentes ao cloro, ozônio e radiação ultravioleta. O efeito sinérgico, promovido pelas desinfecções sequenciais (clororadiação ultravioleta e ozônio-radiação ultravioleta), foi evidenciado em alguns experimentos para todas as bactérias estudadas. O cloro alterou a fluorescência dos cistos de Giardia e o ozônio, além de alterar a fluorescência, foi capaz de diminuir a concentração de cistos desse microrganismo. Pode-se concluir que as concentrações tanto de microrganismos indicadores como de protozoários patogênicos é bastante elevada, qualquer que seja o tipo de esgoto: bruto, efluente do reator UASB ou efluente do lodos ativados. Isso evidencia o extremo cuidado com que estes efluentes devem ser tratados, para posteriores usos ou lançamento em corpo receptor, em especial devido à presença de (oo)cistos ainda viáveis de Giardia spp. e Cryptosporidium spp. mesmo após o tratamento biológico por lodos ativados, e a necessidade de desinfecção do efluente. / This work aimed to evaluate the efficiency of removal of pathogenic protozoa - Giardia spp. and Cryptosporidium spp. - during wastewater treatment by UASB reactor, activated sludge, slow sand filter and different disinfectants. The recovery of Giardia cysts and of Cryptosporidium oocysts, performed by different methodologies and using ColorSeed®, was respectively of 85 and 20%, in raw wastewater and 62.5 and 17.5% in treated effluent, applying triple centrifugation method. Giardia cysts were found in 100% of the the sewage samples surveyed, with average of 1.5 x 104 cysts per liter and Cryptosporidium oocysts were found in 31.4% with average of 3.1 x 10² oocysts per liter, in raw wastewater. Giardia cyst and Clostridium perfringens spores removals were statistically lower than E. coli and total coliforms removal when applying the biological treatment by UASB reactor followed by Activated Sludge. There were no (oo) cysts after treatment tertiary accomplished by slow sand filtration. There was a statistically higher removal in the full scale WWTP for total coliforms and Clostridium perfringens; however, E. coli and Giardia cysts, in both WWTPs, presented the same removal efficiency. High concentrations of (oo)cysts were found in the sludge sludge, with a high percentage still viable. Regarding disinfection, among the indicating bacteria, Clostridium perfringens was more resistant to chlorine, ozone and ultraviolet radiation. The synergic effect promoted by sequential disinfections (chlorine-ultraviolet radiation and ozone-ultraviolet radiation) was evidenced in some experiments for all the bacteria studied. Chlorine altered the fluorescence of Giardia cysts and ozone, as well as change in fluorescence was able to decrease the concentration of this microorganism. It can be concluded that the concentrations of indicator microorganisms as well as of pathogenic protozoa is very high, regardless the kind of wastewater: raw, UASB reactor effluent or activated sludge effluent. This shows the extreme care that must be taken towards these effluents, for future reuse or simply release in the environment, mainly due to the presence of viable Giardia spp. and Cryptosporidium spp. (oo)cysts even after the activated sludge treatment, and the need of disinfection of the effluent.
179

Inativação de indicadores patogênicos em sistemas combinados de tratamento e pré-desinfecção de esgoto sanitário / Inactivation of pathogens tracers in combined systems for sanitary sewer treatment and pre-disinfection

Monaco, Patrícia Bilotta 07 April 2006 (has links)
A proposta apresentada se baseia na introdução de um estágio intermediário de desinfecção previamento ao tratamento biológico visando intensificar os efeitos do estágio seguinte destinado à desinfecção convencional. Para estudo de caso foram aplicadas as técnicas de ozonização e radiação UV combinadas em instalações piloto que simulam duas condições seqüenciais de desinfecção. O desempenho do método proposto foi avaliado através de exames microbiológicos de amostras do efluente anaeróbio previa e posteriormente à desinfecção, utilizando indicadores de contaminação por bactérias (Escherichia coli e coliformes totais), vírus (colifagos) e protozoário (Clostridium perfringens). Os resultados obtidos no sistema combinado pré-desinfecção/desinfecção revelaram eficiência de inativação superior quando comparada ao procedimento convencional. Nas análises de E.coli, por exemplo, a aplicação de apenas 1 mg de ozônio/L ou 51 mW de radiação/'CM POT.2', na primeira etapa de desinfecção, foi suficiente para se alcançar 1 log acima do valor correspondente ao método convencional. Mesmo indicadores mais resistentes como C. perfringens apresentaram redução da fração N/No da ordem de 1 log em relação ao método proposto. Além disso, estes níveis de inativação foram alcançados mesmo sob a influência de elevada concentração de SST, SSV e DQO na entrada na unidade piloto destinada à pré-desinfecção. Entre as seqüências de experimentação investigadas ('O IND.3'/'O IND.3', 'O IND.3'/UV, UV/'O IND.3' e UV/UV) não foram observadas grandes variações. De modo semelhante, os resultados revelaram que a relação N/No, para os indivíduos submetidos ao sistema combinado, não foi afetada pelo aumento no tempo de exposição ao agente inativante ('O IND.3': 5, 7, 10 min; UV: 30, 60, 120s). Considerando as baixas dosagens de 'O IND.3' e UV aplicadas na primeira etapa, somada às condições limitadas de desempenho do sistema real examinado, os níveis de inativação alcançados sugerem grande potencialidade de utilização do método alternativo proposto, comprovando sua viabilidade técnica / The present proposition is based on the introduction of an intermediate disinfection stage before the biological treatment, in order to intensify the effects of the next stage employed in conventional disinfection. Studies were performed using combined ozonization and UV radiation techniques, in a model installation that simulates two sequential disinfection conditions. The performance of the method was evaluated using microbiological exams of samples taken from the anaerobic effluent before and after the disinfection. Bacterial (Escherichia coli and total coliforms), viral (coliphages) and protozoan (Clostridium perfringens contamination tracers were used in such exams. Results obtained by combining pre-disinfection and disinfection reveal superior inactivation efficiency as compared to the conventional procedure. For example, in the E. coli analysis the application of only 1 mg of ozone/L or 51 mW/'CM POT.2' of radiation in the first disinfection stage was enough for achieving 1 log above the convention method. Even more resistant tracers, such as C. perfringens, showed aproximatelly 1 log of reduction in the N/No fraction in the proposed method. Besides, these inactivation levels were achieved even for high concentrations of SST, SSV and DQO in the entrance of the pre-disinfection unit. No significant variations were observed among the disinfection sequences ('O IND.3'/'O IND.3','O IND.3'/UV,UV/'O IND.3', and UV/UV). Similarly, the results showed that the N/No relation, for individuals submitted to the combined system, was not affected by the increase of the exposition time to the inactivation agent ('O IND.3': 5, 7, 10 min; UV: 30, 60, 120 s). Taking into account the low dosages of 'O IND.3' and UV applied in the first stage and the limited performance conditions of the real system, the achieved inactivation levels suggest a great potential for the alternative method proposed, demonstrating its technical viability
180

Estratégia operacional de sistema formado por reator não compartimentado com setores com aeração/sem aeração precedido por reator anaeróbio / Operational strategies of system consisting of non-compartmentalized aerated reactor with sectors with aeration/without aeration preceded by an anaerobic reactor

Almeida, Aurélia de Oliveira 10 October 2014 (has links)
A opção por sistemas biológicos prevalece para o tratamento do esgoto sanitário. Nas décadas recentes, sistemas que possuem regiões e/ou zonas anaeróbia, anóxica e aeróbia têm-se mostrado como alternativas atraentes para remoção simultânea de matéria orgânica, nitrogênio e fósforo. No entanto, os aspectos operacionais ainda merecem ser objeto de estudo para alcançar desempenho otimizado. Nesse cenário, com intuito de comparar alternativas para a operação das unidades de tratamento de esgoto, o presente trabalho propôs-se a estudar estratégias operacionais associadas ao monitoramento, em tempo real, sem adição de fonte externa de carbono, para um reator aerado não compartimentado com crescimento suspenso e fluxo contínuo precedido de reator anaeróbio. O sistema experimental, em escala de bancada, era constituído de um reator anaeróbio, com volume útil de 43,54 L, e reator aerado, com volume útil de 68,07 L; sendo que este era formado por sete setores, em série, sem separação física. O estudo foi dividido em duas etapas: I - estudo da variação dos volumes da região aerada e da não aerada; II - estudo da aeração intermitente com ciclo de aeração/agitação pré-fixado e controlado em tempo real por sistema informatizado. Em todas as Etapas do estudo ocorreu elevada remoção de DBO e conversão de NTK para nitrato, contudo não se conseguiu obter desnitrificação em nível desejado. O uso de reatores com setores sequenciais sem divisão física (Etapa I) dificultou a obtenção de regiões distintas predominantemente anóxica e aeróbia, comprometendo a remoção de nitrogênio (principalmente a desnitrificação). A maior eficiência média de remoção de nitrogênio alcançada no reator aerado foi de 35,6% (Etapa II), quando o reator era operado com aeração intermitente sendo o ciclo de aeração/agitação controlado em tempo real. A estratégia de operação com aeração intermitente, estudada na Etapa II, favoreceu a remoção de nitrogênio. A aeração intermitente demonstrou ser uma opção promissora comparada à aeração contínua em setores específicos do reator. O controle automatizado e informatizado em tempo real dos ciclos de aeração/agitação pode ser aplicado no aperfeiçoamento da operação dos sistemas de tratamento de esgoto sanitário. / The option of biological systems prevails for the treatment of sewage waste and in recent decades, systems that have anaerobic, anoxic, aerobic regions and / or zones have proven attractive for simultaneous removal of organic matter, nitrogen and phosphorus. However, the operational aspects still deserve to be studied in order to achieve the optimized performance of these systems. In this scenario, in order to compare alternatives for the operation of sewage treatment plants, the present work aimed to study operational strategies associated with monitoring, in real time, without the addition of external carbon source, for a non-compartmentalized aerated reactor with growth suspended and continuous flow preceded by anaerobic reactor. The experimental system in bench scale consisted of an anaerobic reactor, with a volume of 43.54 L and an aerated reactor, with a volume of 68.07 L; consisting of seven sectors, in series, without physical separation. The study was divided into two stages: I - study of the variation of the volume of the aerated and non-aerated regions; II - study of intermittent aeration with cycle of aeration/agitation controlled by a pre-fixed time interval; and controlled in real time by a computerized system. In all Stages of the study high BOD removal and conversion of TKN to nitrate occurred, but were unable to obtain denitrification at desired level. The use of reactors with sequential sectors without physical division (Stage I) made it difficult to obtain predominantly distinct anoxic and aerobic regions, compromising the removal of nitrogen (mainly the denitrification). The highest average removal efficiency of nitrogen attained in aerated reactor was 35.6% when the reactor was operated with intermittent aeration with aeration cycle controlled in real time. The operation strategy with intermittent aeration, studied in Stage II, favored the removal of nitrogen. The intermittent aeration proved to be a promising option compared to continuous aeration in specific sectors of the reactor. The automated and computerized control in real-time of the aeration / agitation cycles can be applied in improving the operation of sewage waste treatment systems.

Page generated in 0.0617 seconds