Spelling suggestions: "subject:"estação dde tratamento dde esgoto"" "subject:"estação dde tratamento dee esgoto""
41 |
Projeto de um controlador Fuzzy Takagi-Sugeno para uma estação de tratamento de esgoto por lodos ativadosOLIVEIRA FILHO, José Haroldo Sena de 24 January 2013 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-03-07T15:37:09Z
No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_ProjetoControladorFuzzy.pdf: 1593015 bytes, checksum: 724013024cfa0539e49ad1f252cc7559 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-05-13T17:01:18Z (GMT) No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_ProjetoControladorFuzzy.pdf: 1593015 bytes, checksum: 724013024cfa0539e49ad1f252cc7559 (MD5) / Made available in DSpace on 2014-05-13T17:01:18Z (GMT). No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_ProjetoControladorFuzzy.pdf: 1593015 bytes, checksum: 724013024cfa0539e49ad1f252cc7559 (MD5)
Previous issue date: 2013 / Este trabalho propõe o projeto de um controlador Fuzzy do tipo Takagi-Sugeno em uma estação de tratamento de esgoto por lodos ativados. Este tipo de tratamento ocorre na presença de oxigênio, pois microorganismos aeróbios presentes no licor misto irão proporcionar a remoção tanto da matéria carbonácea quanto nutrientes formados por compostos à base de nitrogênio. O controlador atua via mecanismo de aeração e foi projetado para interpolar os ganhos proporcionais e integrativos de três controladores fixos locais que, por sua vez, foram projetados a partir da linearização de um modelo contínuo de balanço de massa de oxigênio. O controlador auxiliará manter a concentração de oxigênio dissolvido desejável na faixa de operação do processo para que ocorra a nitrificação, reação química de oxiredução que
transforma amônio em nitrito, que é fundamental para o sucesso do processo, e poderá também economizar energia elétrica utilizada pelo mecanismo de aeração. Os ensaios foram realizados via simulação computacional em quatro cenários idealizados comparando o desempenho do controlador fuzzy e o desempenho de um controlador fixo projetado em um ponto de operação diferente do qual se utilizou como valor de referência na planta. Ao aplicar
um degrau no valor de referência estabelecido no cenário de análise, observou-se o tempo de
subida, o tempo de acomodação e o erro em regime. Após os ensaios, observou-se que o
desempenho do controlador fuzzy nos quesitos tempo de subida e tempo de acomodação em
relação ao controlador fixo foi melhor, enquanto nos quesitos sobressinal e erro em regime foi
semelhante. Após as análises, concluiu-se que a estratégia de controle escolhida neste trabalho
é viável, pois de acordo com o valor auferido de oxigênio dissolvido na entrada da planta, o
controlador fuzzy irá interpolar os ganhos proporcionais e integrativos de um controlador fixo
projetado na vizinhança deste valor e assim, atuar de forma bastante satisfatória. / The mean goal of this work is the design of a Takagi-Sugeno fuzzy controller on an activated
sludge wastewater treatment plant. This kind of process requires oxygen and aerobic
microorganisms in the mixed liquor that are necessary to remove the carbonaceous matter and
the nutrients based on nitrogen compounds. The controller acts on the aeration valve engine
and has been designed to interpolate the proportional and integrative gain of three fixes
controllers designed from the linearization of a continuous model of oxygen mass balance.
The controller assists to keep the desirable dissolved oxygen concentration necessary to the
nitrification, an oxi-reduction chemical reaction that transforms ammonia into nitrite and it is
also possible to save electric energy used by the aeration engine. It is imperative the
nitrification occurs for the success of the whole process. The Assays were performed by
computerized simulation in four idealized scenarios analyzing the performances of the fuzzy
controller and the fix controller designed to a different operation point of the set point defined
in the plant. Applying a degree in the set point established in the scenario it was analyzed the
rise time, settling time, overshoot and steady-state error. After the assays, the fuzzy controller
performed better than the fix one at rise time and settling time criteria and equivalent
performance at overshoot and steady-state error. After analysis, it was conclude that the
control strategy chosen in the work is viable, according the dissolved oxygen measure at the
plant entrance, the fuzzy controller interpolate the proportional and integrative gains of a fix
controller designed near this value and thus act quite satisfactory.
|
42 |
Análise da produção de lodo de esgoto e da capacidade de disposição do aterro sanitário do Aurá na região metropolitana de Belém para os próximos 20 anosCUNHA, Débora Suely Anjos 01 July 2009 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-16T12:29:01Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AnaliseProducaoLodo.pdf: 4416450 bytes, checksum: 55ede069de533de6e6b7cf44b8a528d3 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-20T11:13:19Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AnaliseProducaoLodo.pdf: 4416450 bytes, checksum: 55ede069de533de6e6b7cf44b8a528d3 (MD5) / Made available in DSpace on 2017-03-20T11:13:19Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AnaliseProducaoLodo.pdf: 4416450 bytes, checksum: 55ede069de533de6e6b7cf44b8a528d3 (MD5)
Previous issue date: 2009-07-01 / FAPESPA - Fundação Amazônia de Amparo a Estudos e Pesquisas / A Região Metropolitana de Belém possui poucas e incompletas informações sobre a produção e destino final de lodo de esgoto, pois apenas pequena parte do lodo gerado nos tanques sépticos e nas ETEs coletivas é desaguado e disposto sem controle no Aterro Sanitário do Aurá, portanto, é muito comum o lançamento indevido de lodo em corpos d`água e no solo, o que agrava os problemas de poluição/contaminação na área urbana. Sendo assim, esse trabalho tem como objetivo analisar o aumento da produção de lodo e avaliar o seu impacto no Aterro Sanitário do Aurá. A pesquisa foi desenvolvida na Região Metropolitana de Belém, que é composta pelos municípios de Belém, Ananindeua, Benevides, Marituba e Santa Bárbara do Pará. Tendo sido dividida em duas fases. Na Fase I foram estimados os volumes de lodo de esgoto (bruto e desaguado) de tanques sépticos e de ETEs na RMB no período de 2009 a 2030, sendo a Fase II destinada à análise da capacidade do aterro sanitário do Aurá como local de disposição deste lodo. Durante a mesma foi constatado que apesar do aumento do volume de lodo desaguado não ter grande impacto no volume de resíduos sólidos domiciliares no período estudado, a falta de áreas disponíveis no Aterro Sanitário do Aurá é um problema que deve ser resolvido com a máxima brevidade, pois, caso contrário, os resíduos sólidos domiciliares e o lodo de esgoto gerados na Região Metropolitana de Belém, não serão dispostos adequadamente, já que a previsão é o rápido comprometimento do volume livre do Aterro Sanitário do Aurá. / Belém Metropolitan Region has few and incomplete informations about production and destination of sewage sludge, because just little part of the sludge generated in septic tank and collective Sewage Works is throwed away without control in Aurá Sanitary Landfill. Because of this, is usual to throw the sludge in water bodies and in the ground, worsen the problems of pollution/contamination in the urban areas. Therefore, this work has the objective of analyzing the increase of production of sludge and evaluate the impact in the Aurá Sanitary Landfill. The search was developed in Belém Metropolitan Region, composed by Belém, Ananindeua, Benevides, Marituba and Santa Bárbara do Pará. It was divided in 2 stages. In the first stage it was estimated the production of the sludge (brute and drained) of septic tanks and in the collective Sewage Works during 2009 to 2030, and the second one was the availability of an area to disposal in the Aurá Sanitary Landfill. In the period studied, it was verified that by the way of the increase of the content of sludge drainage doesn’t has too many impact in the content of the residence solid waste, the deficiency of the available areas in the Aurá Sanitary Landfill is a problem that has to be solved as soon as possible, otherwise residence solid waste and sewage sludge produced in Belém Metopolitan Region won’t be well disposal, as a matter of fact that the prevision is the fast implicate of the free content of Aurá Sanitary Landfill.
|
43 |
Contaminantes emergentes: ocorrência e distribuição espaço-temporal no rio do Monjolinho e avaliação da remoção pela estação de tratamento de esgotos de São Carlos / Emerging contaminants: occurrence and spatiotemporal distribution in the Monjolinho river and evaluation of removal rate by the sewage treatment plant of São Carlos city.Campanha, Mariele Barboni 27 March 2015 (has links)
Made available in DSpace on 2016-06-02T20:35:03Z (GMT). No. of bitstreams: 1
6749.pdf: 21604971 bytes, checksum: ea6b5030f47becaef3fc6875b8d6bc0e (MD5)
Previous issue date: 2015-03-27 / Universidade Federal de Minas Gerais / This work aimed to investigate the occurrence of 12 emerging contaminants (pharmaceuticals, hormones and triclosan) in samples of influents and effluents, as well the removal in the sewage treatment plant (STP) of São Carlos. It was also investigated the occurrence and spatiotemporal distribution of emerging contaminants in surface waters and sediments from the Monjolinho River, the receptor of effluents, and one of its tributaries, the Água Quente Stream (AQS), which receives the discharge of non treated sewage. Influent and effluent samples were collected weekly. Surface water and sediment samples were obtained every two and four months, respectively, in points since the source until the mouth of the Monjolinho River. The target compounds in dissolved fraction of aquous samples were extracted by solid phase extraction (SPE), while for sediments it was performed ultrassonic extrations with solvents followed by SPE. The analytical determinations were made by ultra high pressure liquid chromatography coupled to mass spectrometer equipped with triplequadrupole analyser (LC-MS/MS). The hormone 17-α-ethynilestradiol was not detected in any sample. However, all the pharmaceuticals evaluated and triclosan were detected in influent samples. The STP with upflow anaerobic sludge blancket (UASB) and air dissolved flotation in São Carlos presented low removal for carbamazepine, diclofenac, propranolol and ibuprofen. On the other hand, triclosan presented the highest removal (91.2%). In surface waters and sediments from Monjolinho river the concentration of contaminants presented an increasing trend since the source of the river to the downstream of the STP effluent discharge and after the confluence of the AQS (which flows into the river at the same place), where it was observed the highest concentrations in the Monjolinho River. The AQS, in its turn, presented higher concentrations of pharmaceuticals and triclosan than the Monjolinho River, due to the discharge of non treated sewage. Carbamazepine and diclofenac were persistent in both STP and aquatic body. The strong correlations between this compounds and electrical conductivity (considered a conservative parameter) sugests that CMZ and DCF can be tracers of both treated and non treated sewage release in the study area. Ee conclude that the main sources of phamaceuticals and triclosan to the Monjolinho River are the discharge of non treated sewage (from the AQS) and effluent from STP, since their removal is very low. Unlike the studies involving endocrine disruptors, the effects of other classes of emerging contaminants have been yet little explained in literature. Therefore, more surveys on the occurrence of these compounds combined with ecotoxicological studies must be conducted to make clear the magnitude of the impact that these substances can cause in the environment. Based on this information, adjustments in the effluent treatment may be investigated in the future, if there is interest in effectively removing this compounds in STP. / Neste trabalho foi investigada a ocorrência de 12 contaminantes emergentes (fármacos, hormônios e triclosan) em amostras de esgoto bruto e tratado, bem como foi avaliada a remoção dos mesmos pela estação de tratamento de esgoto (ETE) de São Carlos. Também investigou-se a ocorrência e distribuição espaço-temporal desses compostos em águas superficiais e sedimentos do rio do Monjolinho, o corpo aquático receptor, e em um de seus afluentes, o Córrego da Água Quente (CAQ), o qual recebe esgoto sanitário não tratado. Amostras de esgoto, águas e sedimentos foram coletadas semanalmente, bimestralmente e a cada quatro meses, respectivamente. No rio do Monjolinho, os pontos de amostragem abrangeram desde a nascente até a foz. Os compostos alvo na fração dissolvida das amostras aquosas foram extraídos por extração em fase sólida (SPE), enquanto que para sedimentos foi realizada extração ultrassônica com solventes, seguida de SPE. As determinações analíticas foram feitas por cromatografia de ultra eficiência acoplada à espectrometria de massas com analisador triplo quadrupolo (UPLC-MS/MS). O hormônio 17-α-etinilestradiol não foi detectado em nenhuma das matrizes avaliadas. Porém, todos os fármacos avaliados e triclosan foram detectados nas amostras de esgoto bruto. O tratamento de esgoto empregando reator anaeróbio de fluxo ascendente (UASB) seguido de flotação por ar dissolvido (FAD) na ETE de São Carlos apresentou baixa remoção para carbamazepina, diclofenaco, propranolol e ibuprofeno, enquanto o triclosan apresentou a maior remoção (91,2%). Nas águas superficiais e sedimentos do rio do Monjolinho as concentrações dos contaminantes foram crescentes desde a nascente até após a confluência do CAQ e o lançamento do efluente da ETE (os quais ocorrem no mesmo local), onde ocorreram as maiores concentrações encontradas no rio do Monjolinho. O CAQ apresentou concentrações mais elevadas de fármacos e triclosan do que o rio do Monjolinho, devido ao aporte de esgoto não tratado. Carbamazepina e diclofenaco foram persistentes tanto em amostras de esgoto quanto no corpo aquático. Fortes correlações entre ambos os compostos e condutividade elétrica (este considerado um parâmetro conservativo) sugerem que os dois fármacos são bons traçadores do aporte de esgoto sanitário tratado e/ou não tratado na área de estudo. Conclui-se que as principais fontes de fármacos e triclosan no rio do Monjolinho são o lançamento de esgoto não tratado (por meio do CAQ) e esgoto tratado, uma vez que a remoção dos mesmos na ETE, é bastante baixa. Ao contrário dos estudos envolvendo desreguladores endócrinos, os efeitos adversos de outras classes de contaminantes emergentes ainda têm sido pouco elucidados na literatura. Portanto, mais pesquisas sobre a ocorrência desses compostos aliados a análises ecotoxicológicas devem ser realizados para que se dimensione a magnitude do impacto que essas substâncias podem causar ao ambiente. Com base em tais informações, adequações no tratamento de esgoto podem ser investigadas, no futuro, caso haja interesse em remover efetivamente esses compostos na ETE.
|
44 |
Avaliação de parâmetros operacionais na cinética de degradação do antibiótico ciprofloxacino pelo processo foto-fentonSantos, Lucilene Cândida dos 29 August 2014 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / In this work the degradation of the antibiotic ciprofloxacin CIP (33.1 mg L-1) by photo-
Fenton process using artificial radiation was evaluated. First, the effect of different
concentrations of Fe 3+ (1.4, 5.6, 11.2 and 16.8 mg L -1) on the kinetics of CIP and dissolved
organic carbon DOC (mineralization), as well as the consumption of H2O2 using 510 mg L-1
of H2O2and pH 2.5-2.8 was studied. The CIP concentration was below of the quantitation
limit of the equipment - LQ (<0.163 mg L-1) in just 2 minutes, for all concentration of Fe3+
evaluated, it was not possible to verify the effect of this operating parameter for the removal
of CIP. Regarding the results of mineralization and consumption of H2O2, the best fit
mathematical observed for all the experimental data obtained at different concentrations of
Fe3+ evaluated, was first order. Furthermore, it was observed that the concentration of Fe3+
resulted in a proportional increase in the rate of mineralization and consumption of H2O2,
being the concentration of 11.2 mg L-1 of Fe3+ chosen for the subsequent experiments. Next,
the effect of different concentrations of H2O2 (85, 170, 340, 510 and 680 mg L-1) on kinetics
of CIP mineralization and consumption of H2O2 using the best concentration of Fe3+ (11.2
mg L-1), and at pH 2.5-2.8 was evaluated. Similar behavior observed for the different
concentrations of Fe3+ was obtained, the best mathematical fit for CIP mineralization and
H2O2 consumption was of first order. The rate of CIP mineralization also increased
proportionally with H2O2 concentration, but up to a certain amount of H2O2 (340 mg L-1).
Above of this concentration, there was a decrease in the rate of mineralization due to the
occurrence of inefficient reactions. These results demonstrate the importance of evaluating the
operational parameters, such as the concentrations of Fenton´s reagents, in order to optimize
the efficiency of the photodegradation process, as well as reduce the costs of processes with
chemical reagents. Thus, the best concentrations obtained experimentally in deionized water
(DW) in relation to the operational parameters evaluated considering the CIP mineralization
using artificial radiation were: [Fe3+] = 11.2 mg L-1 and [H2O2] = 340 mg L-1. Under these
experimental conditions, the influence of different aqueous matrices (simulated seawater -
SW and treated effluent from sewage treatment plant - STP) in the CIP degradation was
evaluated, and the results were compared to those obtained in DW. Complete removal of CIP
(considering the LQ equipment) was influenced by the composition of the matrices, since in
DW occurred after 2 minutes of the photo-Fenton process, while 10 minutes were required in
SW and STP effluent. This is probably due to the presence of inorganic anions (chloride and
sulphate) in SW, which form stable complexes with iron, and also act as scavengers of
hydroxyl radicals, as well as by the presence of natural organic matter present in the effluent
of STP, which also competes with the target-compound by hydroxyl radicals, influencing the
degradation process. Based on the results obtained in this work, it was observed that the
photo-Fenton process can be an alternative of treatment to waters containing CIP, since there
was complete removal of CIP (considering the LQ equipment) after only 2 minutes, followed
by 75% of DOC removal and reduction of acute toxicity to A. saline from 76.7% ± 4.7% to
20.0% ± 10.0% after 60 minutes. Since several ecotoxicological effects are associated with
waste pharmaceuticals, in specific antibiotics, in aquatic environments and conventional
processes fail to remove them efficiently, the application of this process appears quite
feasible. / Neste trabalho foi avaliada a degradação do antibiótico ciprofloxacino CIP (33,1mg L-1)pelo
processo foto-Fenton utilizando radiação artificial. Primeiramente avaliou-se diferentes
concentrações de Fe3+ (1,4, 5,6, 11,2 e 16,8 mg L-1) na cinética de remoção de CIP e carbono
orgânico dissolvido - COD (mineralização), bem como no consumo de H2O2 utilizando-se 510
mg L-1 de H2O2 e pH 2,5-2,8. A concentração de CIP ficou abaixo do limite de quantificação
do equipamento - LQ (< 0,163 mg L-1) em apenas 2 minutos, para todas as concentrações de
Fe3+ avaliadas, não sendo possível verificar o efeito deste parâmetro operacional para a
remoção de CIP. Em relação aos resultados de mineralização e consumo de H2O2, o melhor
ajuste matemático observado para todos os dados experimentais obtidos nos diferentes níveis
de concentração de Fe3+ avaliados foi de primeira ordem. Além disso, foi observado que o
aumento da concentração de Fe3+ resultou num aumento proporcional na velocidade de
mineralização e de consumo de H2O2, sendo a concentração de 11,2 mg L-1 de Fe3+ escolhida
para os experimentos posteriores. A seguir, foi avaliado o efeito de diferentes concentrações
de H2O2 (85, 170, 340, 510 e 680 mg L-1) na cinética de mineralização de CIP e consumo de
H2O2 utilizando a melhor concentração de Fe3+ (11,2 mg L-1), e, em pH 2,5-2,8.
Comportamento semelhante ao observado para as diferentes concentrações de Fe3+ foi obtido,
melhor ajuste matemático para a mineralização de CIP e consumo de H2O2 sendo de primeira
ordem. A velocidade de mineralização de CIP também aumentou proporcionalmente com a
concentração de H2O2, contudo até um determinado valor de H2O2 (340 mg L-1). Acima desta
concentração, houve um decréscimo na velocidade de mineralização devido à ocorrência de
reações ineficientes. Estes resultados, demonstram a importância de avaliar os parâmetros
operacionais, tais como as concentrações dos reagentes de Fenton, a fim de otimizar a
eficiência do processo de fotodegradação, bem como reduzir os custos dos processos com
reagentes químicos. Assim, as melhores concentrações obtidas experimentalmente em água
deionizada (AD) em relação aos parâmetros operacionais avaliados considerando a
mineralização de CIP utilizando radiação artificial foram: [Fe3+] = 11,2 mg L-1 e [H2O2] = 340
mg L-1. Sob tais condições experimentais, a influência de diferentes matrizes aquosas (água de
mar simulada AM, e, efluente tratado de estação de tratamento de esgoto - ETE) na
degradação de CIP foi avaliada, e os resultados foram comparados aos obtidos em AD. A
completa remoção de CIP (considerando o LQ do equipamento) foi influenciada pela
composição da matriz, uma vez que em AD ocorreu após 2 minutos do processo foto-Fenton,
enquanto que 10 minutos foram necessários para a AM e efluente de ETE. Isto ocorreu
provavelmente devido à presença de ânions inorgânicos (cloreto e sulfato) em AM, os quais
formam complexos estáveis com ferro, e que também atuam como sequestradores de radicais
hidroxilas, assim como pela presença de matéria orgânica natural presente no efluente de
ETE, a qual também compete com o composto-alvo pelos radicais hidroxila, influenciando
assim o processo de degradação. Baseado nos resultados obtidos neste trabalho pode ser
observado que o processo foto-Fenton pode ser uma alternativa de tratamento de águas
contendo CIP, pois houve completa remoção de CIP (considerando o LQ do equipamento)
após apenas 2 minutos, seguido de 75% de remoção de COD e redução da toxicidade aguda
para A. salina de 76,7% ± 4,7% para 20,0% ± 10,0% após 60 minutos. Visto que vários
efeitos ecotoxicológicos estão associados aos resíduos de fármacos, em específico
antibióticos, presentes nos ambientes aquáticos e que os processos convencionais não
conseguem removê-los eficientemente, a aplicação deste processo se mostra bastante viável. / Mestre em Química
|
45 |
Composição e estrutura da comunidade fitoplanctônica em lagoas de estabilização da Estação de Tratamento de Esgoto (ETE), Cascavel, Paraná, Brasil / Composition and structure of the phytoplankton community in stabilization ponds of Sewage Treatment Station (ETE), Cascavel, Parana, BrazilRiediger, Wiviany 20 March 2013 (has links)
Made available in DSpace on 2017-07-10T18:13:12Z (GMT). No. of bitstreams: 1
Wiviany Riediger.pdf: 691679 bytes, checksum: 6d7fdb6b83b7be5f6e9c2818bcd38edc (MD5)
Previous issue date: 2013-03-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work aimed to analyze the composition variation seasonal and structure of phytoplankton community in stabilization ponds in Sewage Treatment Station Rio das Antas in the city of Cascavel, noting the influence of environmental variables on this community. The collections of phytoplankton were carried in two points collection between March 2011 and February 2012. A total of 39 taxa were identified, being the most representative class Cyanobacteria both in richness and density. There was a low spatial and temporal variability in phytoplankton composition during the study period. The phytoplankton community showed up with low wealth but high density of species and was represented mainly by classes Cyanobacteria, Chlorophyceae. The Shannon diversity was classified as very low to low, and the equitability, in general, was high. The analysis of permutation of multivariate data showed that statistically the data density of affluence and phytoplankton between periods and sampling sites, to behave similarly. The variation distribution observed throughout the period of study, characterized by replacing, in proportions of Cyanobacteria by Chlorophyceae. The homogeneity of the distribution this species throughout the period of study between sampling sites, probably due to the similar characteristics of sites, comprising high concentration of organic matter, low energy hydrodynamic shallow and restricted circulation of water. / Este trabalho objetivou analisar a variação sazonal da composição e estrutura da comunidade fitoplanctônica em lagoas de estabilização da Estação de Tratamento de Esgotos Rio das Antas do município de Cascavel, observando a influência das variáveis ambientais sobre esta comunidade. As coletas do material fitoplanctônico foram realizadas em dois pontos de amostragem entre março de 2011 e fevereiro de 2012. No total foram identificados 39 táxons, sendo a classe Cianobactéria a mais representativa tanto na riqueza como na densidade. Observou-se uma baixa variabilidade espacial e temporal na composição do fitoplâncton no período de estudo. A comunidade fitoplanctônica apresentou-se com baixa riqueza, porém alta densidade das espécies e esteve representado principalmente pelas classes Cyanobacteria, Chlorophyceae. A diversidade de Shannon foi classificada como muito baixa à baixa e a equitabilidade, de uma maneira geral, foi alta. A análise de permutação dos dados multivariados mostrou que estatisticamente os dados de riqueza e densidade fitoplanctônica entre os períodos e locais amostrados, comporto-se de forma semelhante. A variação de distribuição verificada em todo o período de estudo, é caracterizado com a substituição, das cianobactérias por clorofíceas. A homogeneidade da distribuição das espécies em todo o período de estudo entre os locais amostrados deve-se, provavelmente pelas características similares dos locais, sendo composto por altas concentrações de matéria orgânica, baixa energia hidrodinâmica, baixa profundidade e restrita circulação da água.
|
46 |
Ocorrência de rotavírus, adenovírus, norovírus e vírus da hepatite A em estações de tratamento de esgoto no Rio de Janeiro e avaliação de metodologias de recuperação viral em lodo de esgotoPrado, Tatiana January 2011 (has links)
Submitted by Anderson Silva (avargas@icict.fiocruz.br) on 2012-12-27T16:54:47Z
No. of bitstreams: 1
Tese completa Tatiana Prado doutorado BP pdf.pdf: 8757483 bytes, checksum: 8a4d7a0b6c6b6d917034f958c665cd1a (MD5) / Made available in DSpace on 2012-12-27T16:54:47Z (GMT). No. of bitstreams: 1
Tese completa Tatiana Prado doutorado BP pdf.pdf: 8757483 bytes, checksum: 8a4d7a0b6c6b6d917034f958c665cd1a (MD5)
Previous issue date: 2011 / Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Rio de Janeiro, RJ, Brasil. / Este estudo teve como objetivo avaliar a presença de rotavírus (RVA), adenovírus (AdV),
norovírus (NoV) e vírus da hepatite A (HAV) em amostras ambientais (esgoto e lodo de esgoto
primário e tratado) geradas e obtidas em diferentes Estações de Tratamento de Esgoto (ETEs) da
cidade do Rio de Janeiro pela detecção, quantificação e caracterização molecular, assim como
determinar a eficiência de diferentes metodologias de recuperação viral em lodo de esgoto. A
concentração destes vírus foi determinada em ETEs hospitalares que operam por processos
anaeróbios (reator UASB e filtros anaeróbios) e aeróbio (lodo ativado de aeração prolongada) e
em uma ETE urbana de grande porte (Alegria, Caju) que utiliza processo de lodo ativado
convencional. Os resultados demonstraram que os efluentes hospitalares são contaminados com
elevadas cargas virais, especialmente RVA, apontando para o risco da disseminação ambiental
quando processos de tratamento biológicos convencionais (aeróbios e anaeróbios) não são
adequados para a remoção viral. Uma grande variabilidade de genótipos virais foi encontrada nos
efluentes hospitalares, particularmente para AdV, para os quais foram detectadas espécies C e D,
comumente envolvidas em casos de infecções respiratórias e conjuntivite nosocomial. Apenas
genótipo GII.4 de NoV foi detectado nos efluentes hospitalares, confirmando a prevalência desse
genótipo no Brasil. No estudo que avaliou a detecção de HAV nas águas residuárias urbanas foi
constatado que 58% das amostras de esgoto bruto foram positivas para HAV e as cargas de
genomas virais não foram detectadas nos efluentes tratados do processo de lodo ativado
convencional. A análise filogenética baseada na região do genoma VP1/2A de HAV detectados
em 2009-2010 demonstrou a prevalência do subgenótipo IA e os isolados apresentaram maior
identidade de nucleotídeos com isolados de HAV do Brasil e Argentina. A detecção viral obtida
em diversas etapas da ETE de grande porte demonstrou a predominância de RVA e AdV e o
sistema de lodo ativado convencional reduziu as cargas de genomas virais em 1 – 1,5 unidades
log10 no efluente final tratado. A análise da eficiência dos métodos de detecção viral em lodo de
esgoto demonstrou que a presença de inibidores nas amostras afeta o desempenho da amplificação
de ácidos nucléicos e o uso do controle interno (bacteriófago PP7) pode ser adequado para
monitorar as etapas de detecção viral. O método baseado na eluição utilizando extrato de carne foi
o mais viável para recuperar os vírus pesquisados, sobretudo AdV em lodo de esgoto. Os AdV
foram predominantes nas amostras de lodo de esgoto tratado e, portanto, poderiam ser
considerados bons indicadores para a presença de vírus de disseminação entérica nesses resíduos.
Esse é o primeiro estudo demonstrando a ocorrência de RVA e NoV GII em lodo de esgoto
digerido anaerobicamente no Brasil, e espera-se que esse trabalho contribua para expandir essa
linha de investigação, incluindo a análise de biossólidos produzidos por outros processos de
estabilização. / The aim of this study was to evaluate the presence of rotavirus (RVA), adenovirus (AdV),
norovirus (NoV) and hepatitis A virus (HAV) in environmental samples (sewage and primary and
treated sewage sludge) produced in different wastewater treatment plants (WWTPs) in Rio de
Janeiro city through the detection, quantification and molecular characterization, as well as,
determining the efficiency of different viral recovery methods in sewage sludge. Viral
concentrations were determined in hospital WWTPs that operates by anaerobic processes (UASB
reactor and anaerobic filters) and aerobic (activated sludge process with prolonged aeration) and
in a great urban WWTP (Alegria, Caju) that operates by conventional activated sludge process.
The results demonstrate that hospital wastewaters and treated effluents by anaerobic and aerobic
processes are contaminated with high viral loads, especially RV-A, pointing environmental
dissemination risks when conventional biological treatment processes are not suitable for virus
removal. A great variability of viral genotypes was found, mainly for AdV, which species C and
D involved in respiratory infectious diseases and nosocomial keratoconjuctivites cases were
detected. Only NoV GII.4 was obtained in hospital wastewaters, confirming the prevalence of this
genotype in Brazil. In the study that evaluated HAV detection in urban wastewaters was
demonstrated that 58% of the raw sewage samples were positive for HAV and the viral genome
loads were not detected in the treated effluents from activated sludge process. Phylogenetic
analysis based on VP1/2A genome region of HAV detected in 2009-2010 demonstrated the
prevalence of subgenotype IA and the isolates showed higher nucleotide identity with HAV
isolates from Brazil and Argentina. Virus detection determined in distinct stages of the
conventional activated sludge process demonstrated the predominance of RVA and AdV and viral
genome loads were reduced in 1 – 1,5 log10 units in the treated effluent. Analysis of the virus
recovery methods efficiency in sewage sludge demonstrated that the presence of inhibitors affect
the performance of the nucleic acid amplification reactions and the use of an internal control (PP7
bacteriophage) can be suitable to monitoring viral detection stages. The method based on beef
extract elution was more viable for recovering viruses, mainly AdV in sewage sludge.
Adenoviruses are predominant in these samples and, therefore, could be considered good
indicators to evaluate the viral contamination in these residues. This is the first Brazilian report on
the occurrence of RV-A and NoV GII in sewage sludge treated by anaerobic digestion and is
expected that the present study contributes for the investigation of the enterically disseminated
viruses in biosolids treated by other stabilization processes.
|
Page generated in 0.1029 seconds