• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 103
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 111
  • 111
  • 68
  • 47
  • 42
  • 26
  • 25
  • 25
  • 22
  • 21
  • 19
  • 18
  • 17
  • 16
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Uso racional de água em habitações de interesse social como estratégia para a conservação de energia em Florianópolis, Santa Catarina

Vieira, Abel Silva January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2012. / Made available in DSpace on 2013-06-25T19:31:41Z (GMT). No. of bitstreams: 1 314917.pdf: 2110946 bytes, checksum: 21b02a44a46e1956c395dfe20715dae2 (MD5) / A interdependência entre o consumo de água e o consumo de energia é crescentemente reconhecida como uma das bases para o desenvolvimento sustentável. A escolha das tecnologias para promoção do uso racional de água impacta diretamente a energia incorporada à água. O objetivo geral deste trabalho é avaliar o potencial de economia de energia para operação de sistemas públicos de água e esgoto por meio do uso racional de água em habitações de interesse social em Florianópolis, Santa Catarina. O potencial de economia de energia em escala urbana com o uso racional de água em habitações de interesse social foi verificado para diferentes estratégias, considerando medidas, tais como: (i) instalação de equipamentos economizadores (bacias sanitárias de acionamento duplo e torneiras economizadoras no lavatório e na pia da cozinha); (ii) aproveitamento de água cinza do chuveiro, lavatório, lavadora de roupas e tanque para descarga de bacias sanitárias; e (iii) aproveitamento de água pluvial de coberturas para o abastecimento de lavadoras de roupas, tanques e bacias sanitárias. Para a avaliação do potencial de economia de energia através de estratégias compostas por uma ou mais medidas, estimou-se aparcela dos serviços de água e esgoto atendida por cada medida, bem como suas respectivas intensidades energéticas - unidade de energia por unidade de água ou esgoto. A intensidade energética média das estratégias analisadas variou consideravelmente. A maior intensidade energética média estimada foi para a estratégia que considera o uso de água pluvial sem outra medida para redução do consumo de água da rede pública - 0,86 kWh/m³ -; enquanto, a menor, foi para o uso de equipamentos economizadores combinado com água cinza - 0,41 kWh/m³. Observou-se que quanto maior a redução de efluentes destinados à rede pública de esgoto por uma estratégia, menor é a sua intensidade energética. Por outro lado, a economia de água potável não proporcionou redução significativa da intensidade energética das estratégias em relação aos sistemas públicos. O potencial de economia de energia gerado pelo aproveitamento de água cinza combinado coma instalação de equipamentos economizadores foi igual a 3,9 GWh/ano em escala urbana.<br> / Abstract : The water-energy nexus is increasingly recognized as one of the bases for the sustainable development. The strategies considered into an integrated water management plan have direct implications on the energy embodied into water. The aim of this study is to evaluate the potential for energy savings for operating public water and sewage systems by means of integrated water management strategies in low-income households in Florianópolis, Santa Catarina. The potential for energy savings in urban scale was assessed for different strategies considering water-efficient initiatives, such as: (i) installation of water-saving plumbing fixtures (dual flush toilets and water-efficient taps), (ii) reuse of greywater from shower, washing basin, and laundry for toilet flushing, and (iii) rainwater use for laundry and toilet flushing. In order to assess the potential for energy savings through strategies which encompass the use of one or more initiatives thereof, it was estimated the energy intensity - unit of energy per unit of water or sewage - and the share of water and sewage services met by each initiative. The average energy intensity of the strategies varied considerably. The highest average energy intensity was estimated for the strategy that encompass the use of rainwater without other initiatives to reduce mains water consumption - 0.86 kWh/m³ -; while the lowest was for the use of water-saving plumbing fixtures combined with greywater reuse - 0.41 kWh/m³. It was observed that the strategies which promote the greatest reduction of sewage have the lowest energy intensities (e.g. greywater combined with installing water-saving plumbing fixtures). Therefore, the reduction of sewage is the main factor which underpins the energy efficiency of residential water-efficient strategies. On the other hand, water savings did not give rise to a significant reduction in the energy intensity of the strategies in relation to public systems. The potential for energy savings generated by the reuse of greywater combined with installing water-saving plumbing fixtures was equal to 3.9 kWh/year in an urban scale.
52

Uso de lodo de estações de tratamento de água e de esgoto urbano como condicionador de solo, com ênfase nas propriedades físicas do solo

Colino, Marcelo de Marchi [UNESP] 17 February 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-02-17Bitstream added on 2014-06-13T19:34:37Z : No. of bitstreams: 1 colino_mdm_me_botfca.pdf: 3586052 bytes, checksum: 3142a62e3a58125119c0294a7e6939a3 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Universidade Estadual Paulista (UNESP) / O lodo proveniente das estações de Tratamento de Água e Esgoto Urbano é um material volumoso que sobra nas estações, causando vários transtornos e problemas de ordem ambiental. O emprego deste material, rico em matéria orgânica, na agricultura, é ao que parece a proposta mais viável. O objetivo deste trabalho foi estudar as mudanças nas propriedades físicas de dois tipos de solos, um de textura fina (latossolo roxo) e outro de textura grossa (areia quartzosa), após incorporação de três tipos de lodos provenientes do tratamento de água e de esgoto urbano. As variáveis avaliadas foram os índices físicos (massa específica, massa específica aparente seca, massa específica dos solos, massa específica saturada, massa específica submersa, umidade, porosidade e índices de vazios), condutividade hidráulica de solo saturado e a curva de retenção de água no solo. Adotou-se o delineamento de blocos ao acaso, em esquema fatorial 2 x 3 x 2 x 3 x 3, sendo 2 tipos de solo, 3 tipos de lodo, 2 qualidades de água, 3 épocas de amostragem com 3 repetições de cada amostra. Os resultados mostram que nas condições abordadas, os lodos produzido pelas Estações de Tratamento de Água e Esgoto Urbano, podem ser utilizados na agricultura, como condicionadores de solo, levando a melhoria nas características físicas do solos avaliados neste experimento. / The silt proceeding from the stations of Treatment of Water and Urban Sewer is a voluminous material that surplus in the stations, causing some upheavals and problems of ambient order. The use of this material, rich in organic substance, in the agriculture, is to that seems the proposal most viable. The objective of this work was to study the changes in the physical properties of two types of soil, one of fine texture and another one of thick texture, after incorporation of three types of silts proceeding from the treatment of water and urban sewer. 3 The delineation of blocks to perhaps was adopted, in factorial project 2 x 3 x 2 x 3 x 3, being 2 types of soil, 3 types of silt, 2 qualities of water, 3 times of sampling with 3 repetitions of each sample. The results show that in the boarded conditions, the silt produced per the Stations of Water Treatment and Urban Sewer, can be used in agriculture, as soil conditioning, taking the improvement in the physical characteristics of ground evaluated in this experiment.
53

Automação no controle de perdas e redução de impactos ambientais em sistemas de abastecimento de água

Votre, Rodrigo 22 January 2015 (has links)
Orientadora : Profª. Drª. Daniela Neuffer / CoorientadorA : Profª. Drª. Tânia Mara Pereira Marques / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Mestrado Profissional em Meio Ambiente Urbano e Industrial/ SENAI/ Universität Stuttgart. Defesa: Curitiba, 05/08/2014 / Inclui referências / Resumo: O conhecimento sobre os processos dos sistemas de abastecimento de água (SSA's), dos tipos e perdas existentes no abastecimento de água e das ferramentas de automação, são essenciais para o entendimento das possibilidades de melhorias do desempenho desses sistemas. No saneamento, os principais atrativos para se justificar o investimento em automação residem na melhoria da qualidade do tratamento e distribuição de água, por meio do monitoramento e controle em tempo real, redução de custos operacionais, como produtos químicos e substituição da operação nas unidades por operação remota, além da possibilidade de gerenciamento de energia elétrica consumida, de medições precisas dos volumes de água produzida e distribuída e do controle das variáveis de processo, como pressão, nível e vazão. Entretanto as maiores dificuldades encontradas em um (SSA), residem na quantidade de água perdida e no impacto ambiental gerado, tanto na necessidade de construção de novos sistemas de abastecimento, como nos danos provocados por vazamentos e rompimentos. Para redução destes fatores, foi proposto um estudo de caso avaliativo em um sistema de abastecimento da SANEPAR em Curitiba - PR, Centro de Reservação (CR) Portão, antes e após o advento da automação, visando validar o controle de pressão automatizada via set point de pressão, que possibilitam o controle da variação de velocidade dos conjuntos moto bomba (CMB's) acionados por conversores de frequência. Ao se controlar a pressão num segmento da rede com o uso de conversores de frequência, quando as pressões tendem a aumentar nos pontos críticos, os conversores de frequência se ajustam ao set point de pressão do Controlador Lógico Programável (CLP), variando a velocidade dos CMB's, buscando manter a pressão requerida, ligando ou desligando bombas complementares. Este estudo de caso demonstrou o ganho proporcionado pelo controle de pressão automatizado, tanto na redução de perdas de água, redução de manutenções nas redes de distribuição, como na redução do gasto de energia elétrica e visa a melhoria continua dos processos, colaborando para otimizar o sistema de abastecimento, minimizando possíveis falhas, danos ambientais e financeiros. Palavras-chave:CLP,SSA,CMB,CR,set point,telemetria / Abstract: The knowledge about the processes of water supply systems (WSS's), and types of existing losses in water supply and automation tools are essential for understanding the possibilities for improvement of the performance of these systems. In sanitation, the main attractions to justify the investment in automation reside in improving the quality of treatment and distribution of water, through monitoring and control in real time, reducing operational costs, such as chemicals and replacement of operating units by remote operation, and the possibility of managing electricity consumed, accurate measurements of the volume of water produced and distributed, and control of process variables such as pressure, level and flow. However the greatest difficulties encountered in one (WWS), reside in the amount of water lost and the environmental impact, both in the need to build new supply systems, as the damage from leaks and ruptures. To reduce these factors, we propose an evaluative case study in SANEPAR water suply system, Curitiba - PR, Center Reservation (CR) Portão, before and after the advent of automation, aimed at validating the automated pressure control with set point pressure, enabling control of the speed variation of the motor pump sets (MPS's) driven by frequency converters. By controlling the pressure in a network segment using frequency converters, when pressures tend to increase the critical points, frequency converters adjust the set point pressure of Programmable Logic Controller (PLC), varying the speed of MPS's, seeking to maintain the required pressure by turning on or turning off additional pumps. This case study demonstrated the gain provided by the automated pressure control, either to reduce water losses, reduction of maintenance in distribution networks, such as the reduction of the electric power source and aims at continuous improvement of processes, helping to optimize supply system, minimizing potential failures, environmental and financial damage. Keywords: CLP, WSS, MPS, CR, set point, telemetry
54

Inibição e toxicidade no processo de digestão anaeróbia dos lodos gerados na ETE Brasília Sul : estudo em escala laboratorial / Inhibition and toxicity in anaerobic digestion process of sewage sludge generated at WWTP Brasília Sul : a laboratory-scale study

Vieira, Gabriel Campos 14 July 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2017-10-25T13:42:45Z No. of bitstreams: 1 2017_GabrielCamposVieira.pdf: 826061 bytes, checksum: 40923cf52cea17adb6eb738baed15833 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2017-10-31T13:45:29Z (GMT) No. of bitstreams: 1 2017_GabrielCamposVieira.pdf: 826061 bytes, checksum: 40923cf52cea17adb6eb738baed15833 (MD5) / Made available in DSpace on 2017-10-31T13:45:29Z (GMT). No. of bitstreams: 1 2017_GabrielCamposVieira.pdf: 826061 bytes, checksum: 40923cf52cea17adb6eb738baed15833 (MD5) Previous issue date: 2017-10-31 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES). / A digestão anaeróbia de lodos gerados em Estações da Tratamento de Esgotos (ETE) tem sido amplamente aplicada, principalmente devido ao potencial energético do gás metano gerado. No entanto, processos de inibição/toxicidade na atividadade metanogênica são relatados na presença de lodos gerados por adição de coagulantes à base de alumínio. Nesse sentido, o presente estudo teve como objetivo avaliar a inibição na digestão do lodo misto (LM), mistura na proporção de 1 (v/v) dos lodos primário e biológico (lodos ativados), coletados na ETE Brasília Sul devido ao lodo químico (LQ) (sulfato de alumínio como coagulante) e ao alumínio isoladamente. Os experimentos foram conduzidos em frascos de 1 L e em condições mesofílicas. Proporções de 0, 25, 50, 75 e 100% de LQ (etapa 1) e doses de 0, 0,5, 1,0, 1,5 e 2,0 g/L de Al (OH)3 (etapa 2) foram avaliadas quanto à qualidade do lodo digerido e produção de biogás. Na etapa 1, para as proporções de 50, 75 e 100% de LQ as remoções de SV foram de 10,1, 10,7 e 7,1%, respectivamente. As remoções de DQO também responderam negativamente em presença do LQ, chegando a 35% e praticamente nulas nas proporções de 25, 75 e 100%, respectivamente. Os resultados do teste BMP (Biochemical Methane Potential) mostraram que as proporções de 25, 75 e 100% LQ causaram níveis de inibição na ordem de 30, 38 e 83% na produção de metano em relação ao reator controle ao final de 31 dias, reafirmando os efeitos inibidores causados pelo LQ. Na etapa 2, as doses de Al (OH)3 aplicadas não provocaram maiores efeitos na taxa de remoção de SV em relação ao controle. Para nenhum tratamento houve remoção satisfatória de SV, com máximo de 13% no reator controle. Quanto às remoções de DQO, foram observadas alterações devido à presença do alumínio. A remoção máxima de 52,5% foi observado no reator controle, decrescendo para 42,4, 37,1, 39,2, 39,6% de acordo respectivas doses aplicadas de 0,5, 1,0, 1,5 e 2,0 g/L Al (OH)3. Calculada em relação ao reator com dose de 0,5 g/L e produção máxima de 14,5 NmL CH4/g SV, a inibição para as doses 1,0, 1,5 e 2,0 g/L Al (OH)3 foi de 78,6, 63,4 e 80%, respectivamente ao final de 39 dias. Efeitos de aclimatação também foram observados para as doses de 1,0 e 2,0 g/L, com claras fases de adaptação e recuperação da produção ao nível da atividade do inóculo utilizado no experimento. / Anaerobic digestion of sewage sludge has been widely applied, mainly due to the potential for energy production by methane generation. However, processes of inhibition / toxicity in the methanogenic activity are reported in the presence of sludge generated by the addition of aluminum-based coagulants and polymers. Therefore, the present study had as objective to evaluate the inhibition in the digestion of the mixed sludge (LM), mixing ratio of 1 (v / v) of the primary and biological sludge (activated sludge), coleted in the ETE Brasilia Sul due to chemical sludge (LQ) (aluminum sulphate as coagulant) and the individual effect of aluminum as Al (OH)3. Batch experiments were conducted in 1 L flasks in mesophilic conditions. Proportions of 0, 25, 50, 75 and 100% of LQ (step 1) and doses of 0, 0.5, 1.0, 1.5 and 2.0 g/L of Al (OH)3 (step 2 ) were evaluated for the quality of digested sludge and methane production. In step 1, the proportions of 50, 75 and 100% LQ removed SV for 10.1, 10.7 and 7.1%, respectively. COD removals also responded negatively to LQ, reaching 35% and practically null in proportions of 25, 75 and 100%, respectively. The results of the BMP (Biochemical Methane Potential) test showed that proportions of 25, 75 and 100% LQ caused levels of inhibition for methane production of 30, 38 and 83% compared to the control reactor in 31 days, reaffirming the inhibitory effects caused by LQ on anaerobic digestion. In step 2, aluminum applied doses did not cause greater effects in the SV removal compared to control. For any treatment SV removal was satisfactory, with a maximum of 13% for the control reactor. Regarding the removal of COD, the effect of aluminum was clearly observed. The maximum removal of 52.5% was observed in the control reactor, decreasing to 42.4, 37.1, 39.2, 39.6% for the respective applied doses of 0.5, 1.0, 1.5 and 2.0 g/L Al (OH)3. Compared to the reactor at a dose of 0.5 g / L and maximum production of 14.5 NmL CH4 / g SV, inhibition following the doses of 1.0, 1 , 5 and 2.0 g / L Al (OH)3 were 78,6, 63,4 and 80% respectively at the end of 39 days. Acclimation effects were also observed for the doses of 1.0 and 2.0 g / L, with clear adaptation phases and recovery of the production at the inoculum activity level over the experiment.
55

Estudo de viroma em água de esgoto influente e efluente na estação de tratamento de esgoto norte em Brasília

Moriya, Nataly Mitie Natsume 01 March 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Biologia, Pós-Graduação em Biologia Microbiana, 2018. / Submitted by Raquel Viana (raquelviana@bce.unb.br) on 2018-07-20T17:33:47Z No. of bitstreams: 1 2018_NatalyMitieNatsumeMoriya.pdf: 2644950 bytes, checksum: ea481d769cf8a761af43566c542d198a (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-07-20T19:34:41Z (GMT) No. of bitstreams: 1 2018_NatalyMitieNatsumeMoriya.pdf: 2644950 bytes, checksum: ea481d769cf8a761af43566c542d198a (MD5) / Made available in DSpace on 2018-07-20T19:34:41Z (GMT). No. of bitstreams: 1 2018_NatalyMitieNatsumeMoriya.pdf: 2644950 bytes, checksum: ea481d769cf8a761af43566c542d198a (MD5) Previous issue date: 2018-07-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES). / A contaminação por patógenos humanos na água de esgoto é um assunto importante, principalmente em locais onde as condições de saneamento não são ideais. A tecnologia de Next Generation Sequencing (NGS) tem sido utilizada em diversos estudos metagenômicos virais (viromas). Além de descrever a diversidade genética, é uma ferramenta útil para analisar o viroma em amostras de esgoto. Apesar do interesse no tratamento de água, a cidade de Brasília não possuí um estudo de censo e informações focado na contaminação viral do Lago Paranoá. Com este propósito, os patógenos humanos astrovírus (HAstV), norovírus (NoV) e sapovírus (SaV) foram selecionados e investigados em amostras de água não-tratada (influente) e tratada (efluente) utilizando o NGS. Amostras de influente e efluente (de março, maio de 2016 e fevereiro de 2017) foram coletadas na estação de tratamento de água de esgoto em Brasília, Brasil. As amostras foram submetidas a processos de extração de RNA e as bibliotecas de cDNA foram sequenciadas através do Illumina HiSeq 2000, com a condição de 100 bases paired-end. Os reads foram trimados através do Trimmomatic e os contigs foram montados com os programas Megahit e Velvet. As sequências foram analisadas por tBLASTX e Megablast, respectivamente, contra o "RefSeq Virus" utilizando o software Geneious v.8.1. Os reads resultantes também foram enviados e analisados na plataforma online Kaiju. Os SaV foram detectados nas seis amostras sequenciadas, HAstV e NoV foram encontrados em todas as amostras, exceto no efluente de maio. Os resultados encontrados foram discutidos e comparados com estudos brasileiros e internacionais. / Contamination of human pathogen in wastewater is an important matter, especially where sanitation is not ideal condition. Next Generation Sequencing (NGS) has been applied in several viral metagenomes (viromes) studies. Besides describing gene diversity, it is a helpful tool to analyze virome in sewage water. Despite the interest in wastewater treatment, Brasilia city lacks a census study and information aiming to assess viral contamination in Paranoa lake. For this purpose, the human pathogens astrovirus (HAstV), norovirus (NoV) and sapovirus (SaV) were selected in untreated (influent) and treated (effluent) wastewater and investigated using NGS technology. Samples of influent and effluent stream (from March, May of 2016 and February of 2017) were collected at the treatment station of wastewater in Brasília, Brazil. Samples were submitted to RNA extraction process and the cDNA libraries were sequenced using Illumina HiSeq 2000 with the condition of 100 base paired-end. The NGS reads were trimmed by Trimmomatic and the contigs were assembled with Megahit and Velvet. The assembled contigs were analyzed by tBLASTX and Megablast, respectively, against RefSeq Virus using Geneious Software v.8.1. Resulted reads were also uploaded and analyzed on Kaiju online platform. SaV were detected in the six sequenced samples, HAstV and NoV were found in all samples except the May untreated water sample. The results found were discussed and compared with Brazilian and international studies.
56

Desempenho de reator anaeróbio de fluxo ascendente alimentado com lodo de estação de tratamento de água e esgoto sanitário

Lombardi, Renata [UNESP] 11 December 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-12-11Bitstream added on 2014-06-13T19:56:01Z : No. of bitstreams: 1 lombardi_r_me_jabo.pdf: 915586 bytes, checksum: 30a4ef39c259d9c6fdbfdf4057c6086d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / Nas estações de tratamento de água (ETA), as impurezas retiradas da água juntamente com os produtos hidrolisados dos coagulantes dão origem aos resíduos dos decantadores e das águas de lavagem dos filtros, denominados lodo de ETA. Neste experimento, foi avaliado a disposição de lodo de ETA em reatores anaeróbios de fluxo ascendente com manta de lodo (UASB), com volume de 18 L e 38 L, visando o tratamento para destinação adequada do efluente e do lodo excedente dos reatores. Tal experimento foi dividido em quatro ensaios, com tempo de detenção hidráulica de 24 h nos reatores UASB, previamente inoculados com lodo granulado e floculento. Foram observadas condições em que foram aplicadas ao reator UASB, lodo de ETA, com DQOtotal de 161 mg/L e ST de 1.948 mg/L, e misturas de lodo de ETA com esgoto sanitário nas seguintes proporções, em volume, de 1:1 (lodo de ETA : esgoto sanitário) com DQOtotal de 458 mg/L e ST de 3.039 mg/L; 1:3, com DQOtotal de 519 mg/L e ST de 1.562 mg/L e 1:7, com DQOtotal de 1.174 mg/L e ST de 3.502 mg/L. Os valores médios de eficiência de remoção da DQOtotal foram de 75 a 83% e de ST de 73 a 87%. A maior remoção de P foi de 90% e de N de 41%. As eficiências de remoção de Ca, Co, Fe, Mn, Ni, Cu, Pb, Cr e Zn foram superiores a 70%, confirmando a alta capacidade de bioadsorção de metais do lodo anaeróbio. As concentrações de N-am, Fe, Mn, Ni, Cd, Pb, Cu, Cr e Zn atenderam aos padrões de lançamento de efluentes da legislação federal. Ocorreram remoções de E. coli acima de 90%, resultando contagens do efluente de 1,5x10 UFC/100 mL, apresentando qualidade microbiológica correspondente à água doce de classe 1, conforme os padrões estabelecidos na Resolução CONAMA 357/2005 . O lodo do reator UASB apresentou valores de relação SV/ST e E. coli que permitiram o seu uso na agricultura. / In water treatment plants (WTP), impurities removed from water mixed with coagulative hydrolytic product create waste of decanters and launderings water filters residues called WTP sludge. In this experiment the WTP sludge disposal in an Upflow Anaerobic Sludge Blanket Reactor (UASB) were evaluated, with a volume of 18 L and 38 L, aiming treatment for appropriate disposal of effluent and excess sludge reactors. Such experiment was divided into four assays, with hydraulic detention time of 24 h in UASB reactors by being inoculated previously with flocculent and granular sludge. It was observed conditions in wich it was added to the UASB reactor WTP sludge with CODtotal of 161 mg/L and TS of 1,948 mg/L, and mixtures of WTP sludge and wastewater in the following amounts, in volume, 1:1 (WTP sludge : wastewater) with CODtotal of 458 mg/L and TS of 3,039 mg/L; 1:3 with CODtotal of 519 mg/L and TS of 3,382 mg/L and 1:7 with CODtotal of 1,174 mg/L and TS 3,501 mg/L. The average values of removal efficiency of CODtotal were 75 the 83% and TS 73 the 87%. The highest P removal was 90% and the highest one of N was 41%. Removal efficiencies of Ca, Co, Fe, Mn, Ni, Cu, Pb, Cr and Zn were higher than 70% wich confirmed the high capacity of biosorption and bioaccumulation of metals from anaerobic sludge. Concentrations of Nam, Fe, Mn, Ni, Cd, Pb, Cu, Cr and Zn fit the quality standards of effluent discharge required by federal legislation. There were removals of E. coli higher than 90% which resulted in counts for effluent of 1.5x10 CFU/100 mL and it showed microbiological quality corresponding to freshwater class 1, according to the standards established in CONAMA Resolution 357/2005. Sludge from the reactor showed ratios of VS /TS and E. coli which allows agricultural use.
57

Caracterização e biodegradação de lodo de estações de tratamento de água para descarte em aterro sanitário

Guerra, Ricardo Consigliero [UNESP] 04 March 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:24Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-03-04Bitstream added on 2014-06-13T19:56:03Z : No. of bitstreams: 1 guerra_rc_me_rcla.pdf: 1549626 bytes, checksum: 4e3fd056683f5fd634d2a65641a4f8ae (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A geração e disposição final de resíduos vem se tornando uma preocupação constante em vista dos efeitos negativos proporcionados ao meio ambiente quando estes são dispostos de maneira inadequada. A produção de água para abastecimento público, realizada pelas Estações de Tratamento de Água (ETAs) é responsável pela geração de resíduos, originados pela remoção das partículas em suspensão na água bruta, mediante processos de decantação e filtração. Geralmente, o destino do lodo acumulado nos decantadores é o curso d água mais próximo, sem que nenhum tratamento seja realizado. O objetivo deste trabalho foi verificar a viabilidade da disposição final, em aterro sanitário, dos sólidos resultantes dos processos de secagem do lodo de duas ETAs: ETA Capim Fino, município de Piracicaba, SP e ETA II, município de Rio Claro, SP Os ensaios para a classificação do lodo de ETA foram realizados de acordo com a norma NBR 10.004. Resíduos Sólidos - Classificação (ABNT, 2004a). Os ensaios de biodegradação foram realizados pelo método respirométrico de Bartha (CETESB, 1990), a fim de verificar a influencia da aplicação de diferentes proporções de mistura do lodo de ETA com o solo do aterro sanitário do município de Rio Claro. Os resultados indicam que os lodos estudados, são classificados como resíduos não inertes, necessitando de condições adequadas para sua disposição final, entretanto a aplicação de lodo ao solo do aterro sanitário, não interferiu de forma negativa no processo de biodegradação, indicando que sob esse aspecto, a co-disposição dos sólidos resultantes do processo de secagem dos lodos estudados, juntamente com o solo utilizado na cobertura das células do aterro sanitário do município de Rio Claro, é viável. / The production and ultimate disposal of wastes has become a major concern, related to the negative effects over the environment when its disposal occurs in inappropriate ways. Drinking water production by Water Treatment Plants (WTPs) removes from raw water suspended particles by sedimentation and filtration processes, resulting in waste production. In most cases the destination of the accumulated sludge at the sedimentation basins is the nearest water stream. The objective of this study was to verify the viability of ultimate disposal, at a sanitary landfill, of dewatered sludge from two WTPs: WTP Capim Fino, at Piracicaba, SP and WTP II, at Rio Claro, SP The WTP sludge classification tests wore performed according to the norm NBR 10.004 Solid Wastes - Classification (ABNT 2004a). The biodegradation tests wore performed though Bartha's respirometric method (CETESB, 1990), intending to verify the influence of different mixture proportions of WTP sludge and sanitary landfill soil. The results indicate that these wastes are classified as not inert, demanding adequate conditions to its ultimate disposal, however the sludge and sanitary landfill soil mixture did not interfered negatively at the biodegradation process, indicating that the solids resulting from WTP sludge dewatering can be disposed at Rio Claro sanitary landfill.
58

Avaliação da aplicação de lodo de ETA no adensador de lodo de uma ETE de lodos ativados

Peixoto, Gilmar José [UNESP] 30 October 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-10-30Bitstream added on 2014-06-13T18:38:58Z : No. of bitstreams: 1 peixoto_gj_me_ilha.pdf: 3639925 bytes, checksum: e19f2ebbc3c46fda991b86aa7db634e8 (MD5) / No Brasil, existe um problema comum à maioria das comunidades onde o abastecimento público de água é realizado com água superficial e há a necessidade de tratamento. No processo de tratamento ocorre a formação de resíduos na forma de lodo, o qual periodicamente necessita ser descartado do processo. Exceção feita a algumas Estações de Tratamento de Água (ETA), em nível nacional, todas despejam esses resíduos, de forma bruta, sem nenhum tratamento, em corpos de água. O presente trabalho foi realizado com o objetivo de encontrar solução adequada para destinar, de forma correta, o lodo produzido pela ETA da cidade de Presidente Prudente, operada pela Companhia de Saneamento Básico do Estado de São Paulo (SABESP). O estudo baseou-se na premissa em aplicar o lodo da ETA na Estação de Tratamento de Esgotos (ETE), no adensador por gravidade existente. E, para tanto, foi montada uma ETE Piloto, com a qual foram realizadas as simulações de aplicação de cargas de 2000 mg/L e 4000 mg/L de lodo de ETA A avaliação do desempenho da unidade piloto foi conseguida por meio de monitoramento analítico de parâmetros como: pH, temperatura, oxigênio dissolvido, alcalinidade, DBO, DQO, Fósforo, Nitrogênio, sólidos dissolvidos, totais, fixos e voláteis, turbidez, Índice Volumétrico de Lodo (IVL) e Teor de Lodo (TL). Os resultados mostraram que a carga de 2000 mg/L de lodo de ETA no adensador por gravidade, pode ser realizada sem causar problemas. No entanto, com carga de 4000 mg/L, constatou que as aplicações progressivas de lodo devem ser melhor pesquisadas / In Brazil, very common problem to the biggest part of the communities, where the public water supply is realized using the surface water, and needs to pass by the water treatment plant (WTP). In the treatment process, a residue formation in the form of sludge occurs, which periodically needs to be discarded out the process. Except some WTP, on a nation level all they discarded these residues, in brutal way and without treatment, in watercourses. In this work was realized with the objective to finding an adequate solution to properly allocate the sludge produced in the Water Treatment Plant (WTP) from Presidente Prudente, which is operated by SABESP. This study was based in premise to apply the WTP sludge in the Wastewater Treatment Plant (WWTP), in the thickener by an existing gravity. And however, it was built a WWTP Pilot plant where were realized the simulations of applying dosages of 2000 mg/L and 4000 mg/L of WTP sludge. The evaluation of the performance of the pilot unit was gotten by analytical monitoring of many parameters as: pH, temperature, dissolved oxygen, alkalinity, BOD, COD, phosphorus, nitrogen, dissolved solids, fixed and volatile ones, turbidity, Sludge Volumetric Index (IVL) and sludge concentration (TL). The results showed that the application of 2000 mg/l of WTP sludge in the WWTP gravity thickener can be realized without problems. On the other hand the application of 4000 mg/l showed that progressive applications of sludge have to be better researched
59

Custo-efetividade e padrões ambientais : implicações para tratamento de esgotos no Brasil

Jardim Junior, Attila Moraes 06 November 2006 (has links)
Dissertação (mestrado)—Universidade de Brasília, Departamento de Economia, 2006. / Submitted by Kathryn Cardim Araujo (kathryn.cardim@gmail.com) on 2009-11-27T15:22:26Z No. of bitstreams: 1 2007_AttilaMoraesJardimJunior.PDF: 840404 bytes, checksum: 088f1f0d882c46f90c2100f20f9a0ebb (MD5) / Approved for entry into archive by Carolina Campos(carolinacamposmaia@gmail.com) on 2009-12-03T20:01:29Z (GMT) No. of bitstreams: 1 2007_AttilaMoraesJardimJunior.PDF: 840404 bytes, checksum: 088f1f0d882c46f90c2100f20f9a0ebb (MD5) / Made available in DSpace on 2009-12-03T20:01:29Z (GMT). No. of bitstreams: 1 2007_AttilaMoraesJardimJunior.PDF: 840404 bytes, checksum: 088f1f0d882c46f90c2100f20f9a0ebb (MD5) Previous issue date: 2006-11-06 / Esta dissertação aborda o estabelecimento de ações governamentais para o equacionamento dos serviços de saneamento objetivando a proteção dos recursos hídricos no Brasil. Há um leque de iniciativas necessárias, boa parte delas requerendo elevados investimentos, que quase nunca têm sido disponibilizados em tempo desejável. O trabalho apresenta as perspectivas dos setores de saneamento e de recursos hídricos no Brasil com a promulgação da Lei Federal 11.445/2007. Com relação à alocação de recursos, a dissertação ressalta que ela tem que ser custo-efetiva e que o estabelecimento de padrões deve ter suporte na teoria econômica ambiental. A revisão literária evidenciou que, quando há escassez, o enfoque de atribuir elevados padrões para tratamento de esgotos sem preocupação com custos e prazos envolvidos não oportuniza os maiores ganhos sociais. A diluição de esgoto nos corpos hídricos deveria assumir um nível ótimo de poluição, permitindo que a meta ambiental proporcionasse a maior satisfação à sociedade. Afinal, de um lado, a sociedade deseja recursos hídricos com qualidade ambiental e, de outro, acaba pagando pelos serviços de saneamento na condição de usuária. A dissertação evidencia a complexidade desse tema e avalia, por meio de modelagem, dois tipos de etapalização na implantação de Estações de Tratamento de Esgoto (ETEs) no Brasil: I) abordagem usual à engenharia; e II) abordagem equi-marginal. A modelagem comparativa de implantação por etapas de 4 ETEs, ao Longo de 20 anos, com desembolso de 6 parcelas de mesmo valor nominal, para 4 cargas poluidoras fixas, evidenciou que o enfoque da análise agregada, com o uso do Princípio da Equi-Marginalidade, apresenta ganhos ambientais acumulados 68% superiores ao caminho usual de implantação por etapas de ETEs. Ao mesmo tempo, o ganhos iniciais do enfoque agregado apresentaram-se comparativamente muito superiores. Já na primeira parcela de recursos liberados, a razão entre os níveis de proteção atingidos foi de 3,75. Embora aparentemente paradoxal, o trabalho mostra que na recuperação de cursos hídricos degradados, na condição atual brasileira, a redução imediata dos padrões pode conduzir à obtenção de maior proteção ambiental. ______________________________________________________________________________________ ABSTRACT / This essay deals with the establishment of government actions to offer sanitation services, aiming the protection of the hydro resources in Brazil. There is a variety of necessary initiatives, a great many of them requiring high cost investments, which are never available in time. The work presents the perspectives of the sanitation and hydro sectors in Brazil with the issuing of the Federal Law 11,445/2007. In relation to the liberation of financial resources, the study points out that they must be cost-effective and that the establishment of standards must be supported by the environmental economic theory. The bibliographic revision evidentiated that, when there is scarcity, attributing high standards for the treatment of sewage without worrying about the costs and deadlines involved does not give conditions to achieve higher social gains. The dilution of sewage into the water bodies should assume an optimal level of pollution, allowing this environmental goal to provide the society with a higher level of satisfaction. Thus, on one hand, the society wants water resources with environmental quality and, on the other hand, it has to pay for the sanitation services, as a user. The work analises the complexity of this theme and evaluates, by means of modeling, two kinds of steps in the implementation of Wastewater Treatment Plants Owned and Operated by Municipalities and Local Sewer Districts (POTWs) in Brazil: I) the usual engineering approach; and II) the equimarginal approach. The comparative modeling of implantation by steps of 4 POTWs, during 20 years with the payment in 6 equal parcels, for 4 fixed polluting cargoes, has made evident that the aggregate analysis wit the use of the Principle of Equi-marginality has presented accumulated environmental gains 68% higher than the usual way of implementation of POTWs by steps. At the same time, the initial gains of the aggregated approach presented comparatively higher levels. Even in the first parcel of authorized resources, the rate between the levels of protection attained has been of 3.75 (equimarginal/engineering approach). Though, supposedly a paradox, the study shows that in the recovery of degraded water streams, in the present Brazilian condition, immediate reduction of the standards may lead to a better environment protection.
60

Tratabilidade do lodo de decantadores convencional e de alta taxa

Silva Junior, Archimedes Pereira da 26 February 2003 (has links)
Orientador: Ricardo de Lima Isaac / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-05T08:38:56Z (GMT). No. of bitstreams: 1 SilvaJunior_ArchimedesPereirada_M.pdf: 2766426 bytes, checksum: c4a329b55233959c0c769a4fd9c68911 (MD5) Previous issue date: 2003 / Resumo: Os principais resíduos de ETAs são os Iodos gerados nos decantadores, a água de lavagem dos filtros e o rejeito de limpeza dos tanques de produtos químicos. Os lodos mesmo classificados como resíduos sólidos, apresentam baixíssimo teor de sólidos. Sendo o custo do transporte e disposição final bastante elevado, a redução do volume constitui-se em alternativa, economicamente, viável. Os principais processos utilizados para redução de volume do Iodo são o adensamento, o condicionamento químico e a desaguamento. A pesquisa teve por objetivo comparar a tratabilidade do Iodo do decantador do tipo convencional e do decantador de alta taxa, da SANASA, na cidade de Campinas. Foi verificada a influência dos parâmetros que caracterizam a qualidade do Iodo, no seu desaguamento; o efeito do adensamento do Iodo por gravidade, com auxílio de polímeros e o efeito do condicionamento químico com polímeros no desaguamento, por centrifuga. O lodo bruto foi pré-condicionado com polímeros sintéticos, e também se investigou a eficiência destes no condicionamento do lodo já adensado, para sua centrifugação. O adensamento mostrou que o polímero aniônico foi o melhor para ambas as ETAs. A dosagem ótima foi a mesma para ambas as épocas, para as duas ETAs, sendo de 1mg/g para ETA-3 e 3g/Kg para ETA-4. O tempo de mistura, para ETA-3, foi maior na época seca (45s) do que no período de chuvas (30s). Para ETA-4 o tempo de mistura foi o mesmo (60s) para as duas épocas. O lodo adensado foi condicionado com polímero e submetido à centrifugação. Desta, concluiu-se que, para o período de chuvas e para os dois tipos de lodo a condição ótima foi: polímero catiônico, 1g/Kg, 5s de mistura e 200rpm de rotação. Na época de estiagem e lodo da ETA-3 a condição ótima foi dada por: polímero catiônico, 1g/Kg, 60s de mistura e 200rpm de rotação. No caso da ETA-4, a condição é dada por: polímero catiônico, 2,5g/Kg, 60 s de mistura e 100 rpm / Abstract: The main residues of WTPs are sludge from thickener, filter backwash waters and solids from basins of chemicals products. The sludge even labeled as solid residues present very low solids content. Like the costs of transportation and ultimate disposal are very high, to reduce the sludge volume is an economical feasible alternative. The principal methods used to reduce the sludge volume are thickening, chemical conditioning and dewatering. The aim of this research was to compare the handling of both sludge from the conventional and high-rate thickener. It was checked the influence of the parameters that give particular characteristics to the sludge in its dewatering; the gravity thickening with polymers aid and the influence of the polymers in the sludge dewatering with centrifuge. The raw sludge was conditioned with synthetics polymers. Also was checked whether that polymers were efficient in the thickened sludge conditioning aiming its centrifugation. The best polymer to the gravity thickening for both sludge (WTPs 3 and 4) was the anionic polymer. The same polymer dose was required for the both seasons studied (wet and dry) and for the two WTPs. It was 1mg/g to the WTP-3 and it was 3g/Kg to the WTP-4. The mixing time for the WTP-3 was greater in the dry season (45s) than the wet season (30s) and the mixing time was the same (60s) in both seasons for the WTP-4. The thickened sludge was conditioned with organic synthetic polymer and subjected to centrifugation. After this, was concluded that in the wet season and for the two kinds of sludge the optimum condition s given to: cationic polymer, 1g/Kg of polymer dose, mixing time of 5s and 200 rpm of centrifuge rotation. In the dry season and residues from WTP-3 the optimum condition is given to: cationic polymer, 1g/Kg of polymer dose, mixing time of 60s and 200 rpm of centrifuge rotation. For residues from WTP-4 the optimum condition is given to: cationic polymer, 2,5g/Kg of polymer dose, mixing time of 60s and 100 rpm of centrifuge rotation / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil

Page generated in 0.1415 seconds