• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 55
  • 1
  • 1
  • Tagged with
  • 57
  • 36
  • 28
  • 15
  • 15
  • 13
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

ÉSTERES COMBUSTÍVEIS EM MOTOR DE CICLO DIESEL SOB CONDIÇÕES DE PRÉ-AQUECIMENTO E VARIAÇÃO NO AVANÇO DE INJEÇÃO / ESTERS FUELS IN DIESEL ENGINES UNDER PRE-HEATING CONDITIONS AND VARYING INJECTION TIMING

Machado, Paulo Romeu Moreira 23 April 2008 (has links)
The renewed interest in energy for biomass is supported by the need for different energy sources and the need to protect the environment. Recently, because of increases in crude oil prices, limited resources of fossil oil and environmental concerns there has been renewed focus on vegetable oils and animal fats to make a biodiesel fuel. What is known as biodiesel (methyl or ethyl esters) is a vegetable oil or animal fat chemically treated to replace traditional diesel fuel. Performance parameters and exhaust emissions of a diesel engine fuelled with sunflower and beef tallow ethyl esters and a blend of ethyl and methyl esters, subjected to pre-heating at two temperatures ranges, namely T55 (50 to 60ºC) and T75 (70 to 80ºC), in order to lower its viscosities, have been investigated. Tests were carried out at full load conditions in a four cylinders, four-stroke indirect injection diesel engine. Engine tests, short-term, were conducted at a range speed from 1900 to 4400 rpm. The injection timing was retarded from the manufacturer s recommended setting. The tests were carried out using the same engine and test procedures so that comparative assessments may be made. The tests data were used for evaluating the brake power, exhaust gas temperatures, specific fuel consumption and gaseous emissions. The analysis of the results determined that the level of pre-heating have influence on the performance for used esters. The tests performed at T55 showed the best values of torque (N.m), power (kW) and specific fuel consumption (g.kW-1.h-1) that the tests performed at T75. The bests experiments results were obtained with sunflower ethyl ester and the blend containing 50,0% sunflower ethyl ester and 50,0% beef tallow methyl ester, at -2º BTDC and T55 temperature range. The findings showed that, by using biodiesel, harmful emissions (CO, HC and NOx) can be reduced to some extent of B2 by adjusting the injection pump timing properly and pre-heating of fuel. / O renovado interesse por energia da biomassa é apoiado na necessidade de fontes alternativas de energia e de proteção ambiental. Recentemente, devido ao aumento dos preços do óleo cru, a limitação de seus recursos e as questões relacionadas ao ambiente, um renovado foco passou a existir sobre os óleos vegetais e gorduras animais para produção de um biodiesel combustível. O que é conhecido como biodiesel (éster metílico ou etílico) é um óleo vegetal ou gordura animal tratado quimicamente para substituir o combustível diesel tradicional. Parâmetros de desempenho e emissões de exaustão foram investigados para um motor diesel alimentado com ésteres etílicos de óleo de girassol e de sebo bovino e por uma mistura composta pelo éster etílico de óleo de girassol e pelo metílico de sebo bovino numa proporção volumétrica igual (50,0%+50,0%). Os ésteres estavam sujeitos ao pré-aquecimento segundo duas faixas de temperaturas, chamadas de T55 (50 a 60ºC) e T75 (70 a 80ºC), como forma de redução da viscosidade. Os testes foram conduzidos sob condição de carga máxima em um motor diesel de quatro cilindros, quatro tempos e de injeção indireta de combustível. Os ensaios de curta duração foram efetuados em uma faixa de rotações compreendida entre 1900 e 4400 rpm. O ponto de avanço de injeção foi atrasado em relação ao ponto original recomendado pelo fabricante. Os testes foram conduzidos utilizando o mesmo motor e os mesmos procedimentos de testes para permitir a comparação dos valores obtidos. Nos ensaios foram obtidos os valores de potência, torque, consumo específico de combustível e gases de exaustão. A análise dos resultados indica que o nível de pré-aquecimento tem influência sobre o desempenho dos ésteres utilizados. Os ensaios conduzidos à T55 mostraram melhores valores para torque (N.m), potência (kW) e consumo específico de combustível (g.kW-1.h-1) que os testes executados à T75. Os melhores resultados do experimento foram obtidos pelo éster etílico de girassol e pela mistura contendo 50,0% de éster etílico de girassol e 50% de éster metílico de sebo bovino, sob 2º (P2) de atraso no ponto de injeção e aquecidos na faixa de temperaturas de T55. Os resultados indicam que, pelo uso do biodiesel, as emissões prejudiciais (CO, HC e NOx) podem ser reduzidas aos mesmos níveis do B2 através do ajuste apropriado do ponto de avanço da injeção e o pré-aquecimento do combustível.
52

Síntese de bioadsorvente derivado da quitosana e aplicação na pré-concentração e determinação de íons cobre (II) em álcool etílico combustível por espectrofotometria / Synthesis of bioadsorbent derived form chitosan and application in the preconcentration and determination of copper (II) íons in ethanol fuel by spectrophotometry

Gonsalves, Arlan de Assis 04 January 2012 (has links)
The present work approaches the preparation of a new resin derived from chitosan and its application in the flow preconcentration and spectrophotometric determination of Cu2+ ions in ethanol fuel. The adsorbent was prepared from the functionalization of chitosan with the α-hydroxy-oxime (3-chloro-1-hydroxy-3-methylbutane-2-one oxime) whose modification was confirmed by elemental analysis, FTIR and MEV. Studies of complexation between the ligand and Cu2+ ions showed that the coordination compound has a green color, is  slightly soluble in water, preferably formed at pH 5.8 and absorbs strongly at 435 nm. Adsorption kinetic studies of Cu2+ ions on functionalized chitosan crosslinked with glutaraldehyde follows a pseudo-second order model in 95.0 %(v/v) ethanolic media. The adsorption isotherms of Cu2+ ions in the adsorbent and in ethanol media fit the L2 and S1 type of Giles classification. Desorption studies showed a recovery of 90% of the metal adsorbed using 1.0 mol/L HCl as extractor. The adsorption of Cu2+ ions in ethanol media (~ 93%) was higher than that in water (~ 20%). The flow preconcentration of Cu2+ ions on the prepared adsorbent was realized by a margin from 10.0 to 100.0 ug/L, with an enrichment factor of 20 times, a detection limit of 6.5 ug/L and a quantification limit of 21.6 ug/L, resulting in a gain of sensitivity of 10 times the official cuprizone method. The preconcentration column prepared has been used in more than 60 percolation cycles without apparent loss of efficiency. The analysis of Cu2+ ions  in hydrated ethyl alcohol fuel through flow preconcentration and spectrophotometric determination with cuprizone revealed levels of this metal in the samples that agree, according to the paired t-test and considering  a 95% confidence level, with those obtained in the usual concentration method (evaporation). The standard recovery test showed acceptable recovery rates (92.0 to 107.8%) considering the complexity of the matrices analyzed. The interference of Fe3+ in the preconcentration of Cu2+ ions can be reduced by masking with NaF. The new resin was successfully applied in the flow preconcentration of Cu2+ ions in order the trace analysis of this metal cation in samples of ethanol fuel. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente trabalho aborda a preparação de uma nova resina derivada da quitosana e aplicação na pré-concentração em fluxo e determinação espectrofotométrica de íons Cu2+ em álcool etílico combustível. O adsorvente foi preparado a partir da funcionalização da quitosana com a α-hidroxi-oxima (3-cloro-1-hidroxi-3-metilbutan-2-ona oxima) cuja modificação foi confirmada mediante análise elementar, FTIR e MEV. Estudos de complexação entre o ligante e íons Cu2+ mostraram que o composto de coordenação apresenta uma coloração verde, é pouco solúvel em água, formado preferencialmente em pH 5,8 e absorve intensamente em 435 nm. Estudos de cinética de adsorção de íons Cu2+ em quitosana funcionalizada e reticulada com glutaraldeído segue o modelo de pseudo-segunda ordem em meio etanólico a 95,0%(v/v). As isotermas de adsorção de íons Cu2+ neste adsorvente e em meio etanólico se enquadram no tipo L2 e S1 da classificação de Giles. Estudos de dessorção mostraram uma recuperação de 90% do metal adsorvido usando HCl 1,0 mol/L como extrator. A adsorção de íons Cu2+ em meio etanólico (~93%) foi maior que em meio aquoso (~20%). A pré-concentração em fluxo de íons Cu2+ no adsorvente preparado foi realizada numa margem de 10,0 a 100,0 ug/L, apresentando um fator de enriquecimento de 20 vezes, um limite de detecção de 6,5 ug/L e um limite de quantificação de 21,6 ug/L, resultando em ganho de sensibilidade de 10 vezes no método oficial da cuprizona. A coluna de pré-concentração preparada foi utilizada em mais de 60 ciclos de percolação sem perda aparente de eficiência. As análises de íons Cu2+ em álcool etílico hidratado combustível através de pré-concentração em fluxo e determinação espectrofotométrica com cuprizona revelaram teores deste metal nas amostras concordantes, de acordo com o teste t-pareado e considerando um nível de confiança de 95%, com os obtidos através do método convencional de concentração (evaporação). O teste de recuperação de padrão revelou taxas de recuperação aceitáveis (92,0 a 107,8%) considerando a complexidade das matrizes analisadas. A interferência de Fe3+ na pré-concentração de íons Cu2+ pode ser reduzida mediante mascaramento com NaF. A nova resina foi aplicada com êxito na pré-concentração em fluxo de íons Cu2+ visando a análise de traços deste cátion metálico em amostras de álcool etílico combustível.
53

Desinfecção das canetas de alta rotação com álcool 70% p/v sem limpeza prévia: avaliação do risco de infecção cruzada / Disinfection of high-speed dental equipment with 70% ethanol without previous cleaning: assessment of cross-infection risk

Pinto, Flávia Morais Gomes 17 June 2013 (has links)
Introdução: Na prática clínica odontológica, justificada pela praticidade, tempo curto disponível entre os atendimentos, associados à insuficiente previsão e provisão das Canetas de Alta Rotação (CAR), a descontaminação destas por meio de aplicação direta do álcool 70% p/v, sem limpeza prévia, é uma realidade. Este procedimento contraria, a priori, os protocolos de processamento que recomendam, no mínimo, limpeza seguida de desinfecção de alto nível para prevenção de infecção cruzada. Objetivo: avaliar a desinfecção das CAR com álcool 70% p/v, sem limpeza prévia com vistas ao risco de causar infecção cruzada. Método: caracterizou-se como uma pesquisa pragmática em um Estabelecimento Odontológico, onde rotineiramente as práticas de interesse para o estudo estavam presentes. O grupo experimental foi composto por 100 amostras de CAR utilizadas em tratamentos diversos, após a fricção do desinfetante por 90 segundos em sua superfície externa. Para avaliação dos resultados, uma gaze umedecida com soro fisiológico foi utilizada como carreador para o arraste dos possíveis micro-organismos nas superfícies desinfetadas. Metade do número das amostras (50) foi analisada pelo método de filtração por membrana (Método I - quantitativo), sendo cada gaze imersa em 300 mL de solução fisiológica. Sequencialmente, as amostras foram expostas a sonicação e agitação. Em seguida, o lavado foi filtrado em três partes iguais para diferentes análises (micro-organismos aeróbios, anaeróbios e específicos da microbiota oral humana), por meio da membrana com porosidade de 0,45 m. As outras 50 amostras foram analisadas pelo método de imersão direta da gaze em meio de cultura Fluid Thioglycollate Medium (Método II qualitativo). O tubo contendo a gaze foi agitado e incubado a 37ºC por 21 dias. Resultados: as amostras analisadas pelo Método I apresentaram crescimento positivo em 27/50 (54%) das amostras na faixa de 100 a 102 UFC/amostra. Deste total, foram identificados sete micro-organismos distintos, representados por 37,1% do Staphylococcus coagulase negativa, 28,5% dos Bacillus spp, 17,1% dos Bacilo Gram positivos não esporulados, 5,7% dos Micrococcus spp, 5,7% dos Penicillium spp, 2,8% Acinetobacter baumannii e 2,8% da Candida spp. No grupo analisado pelo Método II, o total de tubos com crescimento positivo foi de 12/50 (24%) amostras. Deste total, foram identificados três micro-organismos distintos, sendo 38,4% de Bacilos Gram positivos inespecíficos, seguidos dos Staphylococcus spp e Peptococcus spp com a mesma porcentagem de positividade de 30,7% cada. O grupo controle negativo, composto por amostras submetidas à limpeza e esterilização consecutiva, apresentaram resultados satisfatórios de ausência microbiana na totalidade das amostras. O crescimento médio encontrado no grupo controle positivo foi de 17,5 UFC/placa, com exceção de uma amostra que apresentou crescimento incontável. Conclusão: os resultados da presente investigação reprovam a prática da descontaminação das CAR com álcool 70% p/v, sem limpeza prévia, substanciada pela sobrevivência de micro-organismos que não corresponderam à ação fungicida e bactericida esperada do álcool 70% p/v na condição de desinfetante de nível intermediário. Outro aspecto que reforça a reprovação da prática analisada é a consideração de que os micro-organismos recuperados, mesmo sendo de baixo potencial patogênico, podem comportar-se como anfibiontes, isto é, são capazes de agredir o hospedeiro quando as condições ambientais e imunológicas são favoráveis aos micro-organismos, causando infecção. / Introduction: In dental clinical practice, decontamination of high-speed dental equipment (HSDE) by direct use of 70% ethanol without previous cleaning, justified by practicality, the short-time available between appointments, together with inadequate predicting and provision of HSDE, is a reality. This procedure, a priori, contradicts the processing protocols recommended to prevent cross-infection. Objective: to evaluate the disinfection of HSDE with 70% ethanol without previous cleaning, with views of cross-infection risk. Method: the present study was characterized as a pragmatic research in a Dental Office, which practices of interest to the study were routinely performed. The experimental group consisted of 100 samples of HSDE used in different treatments after rubbing the disinfectant for 90 seconds on its outer surface. To evaluate the results, gauze moistened with saline solution was used as a carrier for obtaining microorganisms from the disinfected surfaces. Half of the samples (50) were analyzed by membrane filtration (Method I - quantitative), with the gauze being immersed in 300 mL of saline solution. Sequentially, the sample was exposed to sonication and agitation. After that, the lavage was filtered in three equal parts for different analyses, through a membrane with 0.45 m porosity and seeded on blood agar culture medium, for recovery of aerobic and anaerobic microorganisms, as well as those specifically found in the human oral microbiota. The other 50 samples were analyzed by direct immersion of the gauze in culture medium (Method II - Qualitative): after rubbing the wet gauze on the outer surface of the HSDE, it was placed directly in Fluid Thioglycollate culture medium. The tube containing the gauze was shaken in a vortex mixer and then incubated at 37 ° C for 21 days. Results: samples analyzed by Method I, showed positive growth in 27/50 (54%) of the samples within the range of 100 to 102 CFU/sample. Of this total, 7 different microorganisms were identified, represented by 37.1% of coagulase-negative Staphylococcus, 28.5% of Bacillus spp, 17.1% of non-sporulating Gram-positive bacillus, 5.7% of Micrococcus spp, 5.7 % of Penicillium spp, 2.8% of Acinetobacter baumannii and 2.8% of Candida spp. In the group analyzed by Method II, the total number of tubes with positive growth was 12/50 (24%) samples. Of this total, we identified 2 different microorganisms, being 38.4% of Gram-positive bacillus nonspecific, followed by Staphylococcus spp and Peptococcus spp with the same percentage of positivity of 30.7% each. The negative control group, composed of samples subjected to cleaning and sterilization consecutive showed satisfactory results. The average growth found in the positive control group was 17.5 CFU/sample, except for one sample that showed growth uncountable. Conclusion: the results of the present study do not support the practice of decontamination of HSDE with 70% ethanol without previous cleaning, based on the evidence of microorganism survival that did not meet the expected bactericidal and fungicidal action of alcohol as an intermediate level disinfectant. Another aspect that reinforces the disapproval this practice, it is the consideration that the micro-organisms recovered, even being low pathogenic potential, may behave as anfibionte, which are capable of harming the host when the environmental and immune conditions are favorable to micro-organisms, causing infection.
54

Desinfecção de nível intermediário de endoscópio rígido por meio de limpeza prévia com detergente seguido de álcool etílico 70% p/v: protocolo operacional padrão / Disinfection of intermediate level of rigid endoscope through prior cleaning with detergent followed by ethyl alcohol 70% w/v: standard operating protocol

Santos, Marco César Jorge dos 11 June 2018 (has links)
INTRODUÇÃO: A limpeza prévia de endoscópios rígidos (ER) seguida de desinfecção de nível intermediário com álcool etílico a 70% p/v após o exame de endoscopia nasal é uma prática adotada em muitos serviços de otorrinolaringologia. A literatura atual, no entanto, recomenda a esterilização ou desinfecção de alto nível como o método de descontaminação mais aceito para produtos para saúde classificados como semicríticos. No entanto, há que se fazer distinção entre equipamentos de alta complexidade e sua invasividade como os endoscópios flexíveis com lumens longos e estreitos utilizados na endoscopia digestiva, daqueles de conformação simples sem lumens de baixa invasividade como os endoscópios rígidos utilizados em otorrinolaringologia. OBJETIVO: Avaliar a segurança da desinfecção de nível intermediário com álcool etílico 70% p/v, após limpeza prévia dos endoscópios rígidos utilizados em procedimentos clínicos de endoscopia nasal considerando a carga microbiológica recuperada após o uso. MÉTODO: Imediatamente após a realização do exame, uma gaze úmida foi utilizada para o arraste da carga biológica do endoscópio rígido, gerando as amostras do Controle Positivo e, após a aplicação do POP, um novo arraste para constituir as amostras do Grupo Experimental. Estas gazes foram inicialmente submetidas à sonicação e agitação imersas em soro fisiológico e em seguida a solução foi submetida a uma técnica de extração de carga microbiológica por filtragem por meio de uma Membrana de Celulose de 0,22um de poro que foi, em seguida, semeada nos meios de ágar Sangue, Chocolate, Sabouraud, Löwenstein-Jensen e Tioglicolato. Estes meios ficaram incubados em estufa a 37ºC ± 2ºC e avaliados, no máximo, até por 60 dias conforme o perfil de crescimento dos diferentes microrganismos de interesse; foram analisados de maneira quantitativa e qualitativa para identificação e classificação dos micro-organismos recuperados após as semeaduras. RESULTADO: Os resultados da análise estatística evidenciaram diferença significativa entre Controle Positivo e Grupo Experimental quando comparados em relação à presença de Streptococcus coagulase negativa (p < 0,001), Bacillus spp (p < 0,001) e Staphylococcus aureus (p=0,001). No Controle Positivo, foram encontradas presença desses micro-organismos respectivamente na seguinte frequência: 63,2%, 28,9% e 28,9%, enquanto que, no Grupo Experimental, não foi houve recuperação microbiana alguma. CONCLUSÃO: Os resultados desta pesquisa demonstram a eficiência, na prática diária, da desinfecção de nível intermediário dos endoscópios utilizados na otorrinolaringologia por meio da fricção com álcool etílico 70% p/v por 90 segundos, com protocolo de limpeza prévia / INTRODUCTION: Prior cleaning of rigid endoscopes (REs) followed by intermediate-level disinfection with 70% ethyl alcohol (w/v) after nasal endoscopy is a common practice in many otolaryngology services. Current literature, in turn, recommends high-level sterilization or disinfection as the most accepted decontamination method for health products classified as semi-critical. However, it is necessary to distinguish highly complex equipment according to their invasiveness, e.g., flexible endoscopes with long and narrow lumens used in digestive endoscopy and those with a simple conformation without lumens of low invasiveness, such as rigid endoscopes used in otorhinolaryngology. OBJECTIVE: To evaluate the safety of intermediate-level disinfection with 70% ethyl alcohol (w/v) after cleaning of REs used in clinical procedures of nasal endoscopy considering the microbiological load recovered after use. METHOD: Immediately after the test, a wet gauze was used to drag the biological load from the RE, generating positive control samples; after applying POP, dragging was carried out again to generate samples of the experimental group. These gasses were initially subjected to sonication and shaking while immersed in physiological saline; the solution was then subjected to the microbiological loading technique by filtration through a 0.22-um pore cellulose membrane and then cultivated on blood, chocolate, Sabouraud, Löwenstein-Jensen, and thioglycolate agar media. These media were incubated at 37ºC ± 2ºC and evaluated for up to 60 days, according to the growth profile of the different microorganisms of interest. A quantitative and qualitative analysis was performed for the identification and classification of microorganisms recovered after cultivation. RESULTS: The results of statistical analysis showed a significant difference between the positive control and experimental groups for the presence of coagulase-negative Streptococcus (p < 0.001), Bacillus spp (p < 0.001), and Staphylococcus aureus (p=0.001). In the positive control group, these microorganisms were found in the following proportions: 63.2%, 28.9%, and 28.9%, respectively, whereas in the experimental group, no microorganisms were recovered. CONCLUSION: The results of this study demonstrate the efficiency of the daily practice of intermediate-level disinfection of endoscopes used in otorhinolaryngology by means of treatment with 70% ethyl alcohol (w/v) for 90 seconds, using a previous cleaning protocol
55

Estudo da pré-hidrólise ácida da palma forrageira (Opuntia ficus-indica Mill). / Study of acid pre-hydrolysis of forage palm (Opuntia ficus-indica Mill).

TORRES NETO, Alberto Brandão. 16 October 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-10-16T17:10:00Z No. of bitstreams: 1 ALBERTO BRANDÃO TORRES NETO - DISSERTAÇÃO PPGEA 2009..pdf: 8942773 bytes, checksum: 5e58ef74c4a8c8c72d4700726c6be397 (MD5) / Made available in DSpace on 2018-10-16T17:10:00Z (GMT). No. of bitstreams: 1 ALBERTO BRANDÃO TORRES NETO - DISSERTAÇÃO PPGEA 2009..pdf: 8942773 bytes, checksum: 5e58ef74c4a8c8c72d4700726c6be397 (MD5) Previous issue date: 2009-09 / Desde a primeira crise do petróleo, em 1973, o álcool etílico vem despertando um crescente interesse do Governo Federal do Brasil e dos pesquisadores do mundo, e atualmente dos governos dos países desenvolvidos, como os Estados Unidos, Alemanha, França e países em desenvolvimento, como a índia e a China. Este fato se deve às pressões do esgotamento das fontes não-renováveis de combustíveis fósseis, como também à geopolítica do mundo (maiores reservas de petróleo em países com problemas de conflitos e instabilidade política). Surge, também, a busca por novas fontes de obtenção do álcool, os materiais lignocelulósicos. A palma forrageira foi introduzida no Brasil para dar suporte à criação de um inseto conhecido como cochonilha, este responsável pela produção de um corante de alto valor comercial na época. Com o passar dos anos o uso da palma passou a ser bastante diversificado pois, além de servir como forragem, ela produz frutas e verduras para consumo humano, biomassa para fins energéticos (combustível e biogás) e inúmeros produtos como bebidas, queijo vegetariano, remédios e cosméticos; elas servem, ainda, para abrigar e alimentar diversas espécies selvagens que vivem em ambientes áridos. A palma forrageira vem despertando interesse de muitos pesquisadores por se tratar de uma cultura bastante difundida e apresentar, em sua composição, celulose e hemicelulose, substâncias que podem ser utilizadas para obtenção de açúcares fermentescíveis; ela é, também, uma cultura bastante resistente à seca e produzida o ano inteiro. O objetivo deste trabalho foi estudar o processo de pré-hidrólise ácida da palma para obtenção de um licor pré-hidrolisado rico em pentoses diminuindo, assim, suas concentrações na matéria-prima, sendo esta o cladódio da palma forrageira do tipo gigante. O cladódio da palma foi recepcionado no Laboratório de Engenharia Bioquímica, onde se determinou sua umidade e se obteve a matéria seca. Fez-se a caracterização desta matéria (pH, açúcares redutores totais, sólidos solúveis, cinzas, hemicelulose, celulose, lignina e concentração de pentoses e hexoses). Foram realizados dois planejamentos experimentais 23 da pré-hidrólise para verificar a influência das variáveis temperatura, concentração de ácido e razão matéria seca/ácido sobre as respostas soma de pentoses e percentual de aumento de pentoses e, em seguida, foi realizada uma hidrólise preliminar acompanhada de uma fermentação. Com os resultados do planejamento fatorial experimental 23 verificou-se que apenas o segundo planejamento foi estatisticamente significativo ao nível de 95% de confiança para a média e a variável razão. Operando-se com razão abaixo de 1/10, para quaisquer valores de temperatura e concentração de ácido, obtém-se soma e percentual de aumento de pentoses acima de 8 g/L e 8000%, respectivamente. Durante a fermentação não houve produção de álcool etílico, devido, provavelmente, à formação de inibidores no processo de hidrólise, que se demonstrou através da forte coloração no licor hidrolisado. / Since the first petroleum crisis in 1973, ethylic alcohol has been arousing a growing interest by the Federal Government in Brazil and by researchers worldwide, and nowadays by governments of developed countries, such as the United States, Germany, and France, and by developing countries, such as índia and China. This is due to the pressure caused by the depletion of non-renewable sources of fóssil fuels, as well as to world geopolitics (greater reserves of petroleum in countries with problems of conflicts and politicai instability). The search for new sources for obtaining alcohol, such as lignocelluloses materiais, is also arising. Forage cactus was introduced in Brazil to support the raising of an insect known as cochonilha, which is responsible for the production of a dye that was of high commercial value at that time. Throughout the years, the use of this cactus has become very diversified, because aside from being used as forage, it produces fruit and greens for human consumption, biomass for energy reasons (fuels and biogas) and countless other products, such and beverages, vegetarian cheese, medicines and cosmetics. Furthermore, it is useful to shelter and feed various wild species that live in arid environments. Forage cactus has been arousing interest among many researchers because it is not only a greatly diffused culture and presents cellulose and hemicelluloses in its composition, and these substances can be used for obtaining fermentable sugars, but it is also a culture which is resistant to drought and can be produced ali year long. The purpose of this paper was to study the process of acid pre-hydrolysis of the cactus to obtain a prehydrolyzed liquor, high in pentose, thus diminishing the concentration in this raw material, which is the cladode of the giant forage cactus. The cactus cladode was received at the Biochemistry Engineering Laboratory, where its moisture content was determined and a dry matter was obtained. This matter was characterized (pH, total reducing sugars, soluble solids, ashes, hemicelluloses, cellulose, lignin, and the concentration of pentose and hexoses). Two factorial designs 23 of pre-hydrolysis were performed to verify the influence of the variables of temperature, acid concentration and dry matter/acid ratio over the responses to the sum of pentose and the percentile of pentose increase, and then a preliminary hydrolysis followed by fermentation was performed. With the results to the factorial design 23, it was verified that only the second design was statistically significant to a 95% levei of confidence for the mean and the variable ratio. Operating with the ratio below 1/10, for any value of temperature and acid concentration the sum and percentile increase in pentose is obtained above 8 g/L and 8000%, respectively. During fermentation, there wasn't production of ethylic acid, probably due to the formation of inhibitors in the hydrolysis process that was demonstrated through the strong color of the hydrolyzed liquor.
56

Desinfecção das canetas de alta rotação com álcool 70% p/v sem limpeza prévia: avaliação do risco de infecção cruzada / Disinfection of high-speed dental equipment with 70% ethanol without previous cleaning: assessment of cross-infection risk

Flávia Morais Gomes Pinto 17 June 2013 (has links)
Introdução: Na prática clínica odontológica, justificada pela praticidade, tempo curto disponível entre os atendimentos, associados à insuficiente previsão e provisão das Canetas de Alta Rotação (CAR), a descontaminação destas por meio de aplicação direta do álcool 70% p/v, sem limpeza prévia, é uma realidade. Este procedimento contraria, a priori, os protocolos de processamento que recomendam, no mínimo, limpeza seguida de desinfecção de alto nível para prevenção de infecção cruzada. Objetivo: avaliar a desinfecção das CAR com álcool 70% p/v, sem limpeza prévia com vistas ao risco de causar infecção cruzada. Método: caracterizou-se como uma pesquisa pragmática em um Estabelecimento Odontológico, onde rotineiramente as práticas de interesse para o estudo estavam presentes. O grupo experimental foi composto por 100 amostras de CAR utilizadas em tratamentos diversos, após a fricção do desinfetante por 90 segundos em sua superfície externa. Para avaliação dos resultados, uma gaze umedecida com soro fisiológico foi utilizada como carreador para o arraste dos possíveis micro-organismos nas superfícies desinfetadas. Metade do número das amostras (50) foi analisada pelo método de filtração por membrana (Método I - quantitativo), sendo cada gaze imersa em 300 mL de solução fisiológica. Sequencialmente, as amostras foram expostas a sonicação e agitação. Em seguida, o lavado foi filtrado em três partes iguais para diferentes análises (micro-organismos aeróbios, anaeróbios e específicos da microbiota oral humana), por meio da membrana com porosidade de 0,45 m. As outras 50 amostras foram analisadas pelo método de imersão direta da gaze em meio de cultura Fluid Thioglycollate Medium (Método II qualitativo). O tubo contendo a gaze foi agitado e incubado a 37ºC por 21 dias. Resultados: as amostras analisadas pelo Método I apresentaram crescimento positivo em 27/50 (54%) das amostras na faixa de 100 a 102 UFC/amostra. Deste total, foram identificados sete micro-organismos distintos, representados por 37,1% do Staphylococcus coagulase negativa, 28,5% dos Bacillus spp, 17,1% dos Bacilo Gram positivos não esporulados, 5,7% dos Micrococcus spp, 5,7% dos Penicillium spp, 2,8% Acinetobacter baumannii e 2,8% da Candida spp. No grupo analisado pelo Método II, o total de tubos com crescimento positivo foi de 12/50 (24%) amostras. Deste total, foram identificados três micro-organismos distintos, sendo 38,4% de Bacilos Gram positivos inespecíficos, seguidos dos Staphylococcus spp e Peptococcus spp com a mesma porcentagem de positividade de 30,7% cada. O grupo controle negativo, composto por amostras submetidas à limpeza e esterilização consecutiva, apresentaram resultados satisfatórios de ausência microbiana na totalidade das amostras. O crescimento médio encontrado no grupo controle positivo foi de 17,5 UFC/placa, com exceção de uma amostra que apresentou crescimento incontável. Conclusão: os resultados da presente investigação reprovam a prática da descontaminação das CAR com álcool 70% p/v, sem limpeza prévia, substanciada pela sobrevivência de micro-organismos que não corresponderam à ação fungicida e bactericida esperada do álcool 70% p/v na condição de desinfetante de nível intermediário. Outro aspecto que reforça a reprovação da prática analisada é a consideração de que os micro-organismos recuperados, mesmo sendo de baixo potencial patogênico, podem comportar-se como anfibiontes, isto é, são capazes de agredir o hospedeiro quando as condições ambientais e imunológicas são favoráveis aos micro-organismos, causando infecção. / Introduction: In dental clinical practice, decontamination of high-speed dental equipment (HSDE) by direct use of 70% ethanol without previous cleaning, justified by practicality, the short-time available between appointments, together with inadequate predicting and provision of HSDE, is a reality. This procedure, a priori, contradicts the processing protocols recommended to prevent cross-infection. Objective: to evaluate the disinfection of HSDE with 70% ethanol without previous cleaning, with views of cross-infection risk. Method: the present study was characterized as a pragmatic research in a Dental Office, which practices of interest to the study were routinely performed. The experimental group consisted of 100 samples of HSDE used in different treatments after rubbing the disinfectant for 90 seconds on its outer surface. To evaluate the results, gauze moistened with saline solution was used as a carrier for obtaining microorganisms from the disinfected surfaces. Half of the samples (50) were analyzed by membrane filtration (Method I - quantitative), with the gauze being immersed in 300 mL of saline solution. Sequentially, the sample was exposed to sonication and agitation. After that, the lavage was filtered in three equal parts for different analyses, through a membrane with 0.45 m porosity and seeded on blood agar culture medium, for recovery of aerobic and anaerobic microorganisms, as well as those specifically found in the human oral microbiota. The other 50 samples were analyzed by direct immersion of the gauze in culture medium (Method II - Qualitative): after rubbing the wet gauze on the outer surface of the HSDE, it was placed directly in Fluid Thioglycollate culture medium. The tube containing the gauze was shaken in a vortex mixer and then incubated at 37 ° C for 21 days. Results: samples analyzed by Method I, showed positive growth in 27/50 (54%) of the samples within the range of 100 to 102 CFU/sample. Of this total, 7 different microorganisms were identified, represented by 37.1% of coagulase-negative Staphylococcus, 28.5% of Bacillus spp, 17.1% of non-sporulating Gram-positive bacillus, 5.7% of Micrococcus spp, 5.7 % of Penicillium spp, 2.8% of Acinetobacter baumannii and 2.8% of Candida spp. In the group analyzed by Method II, the total number of tubes with positive growth was 12/50 (24%) samples. Of this total, we identified 2 different microorganisms, being 38.4% of Gram-positive bacillus nonspecific, followed by Staphylococcus spp and Peptococcus spp with the same percentage of positivity of 30.7% each. The negative control group, composed of samples subjected to cleaning and sterilization consecutive showed satisfactory results. The average growth found in the positive control group was 17.5 CFU/sample, except for one sample that showed growth uncountable. Conclusion: the results of the present study do not support the practice of decontamination of HSDE with 70% ethanol without previous cleaning, based on the evidence of microorganism survival that did not meet the expected bactericidal and fungicidal action of alcohol as an intermediate level disinfectant. Another aspect that reinforces the disapproval this practice, it is the consideration that the micro-organisms recovered, even being low pathogenic potential, may behave as anfibionte, which are capable of harming the host when the environmental and immune conditions are favorable to micro-organisms, causing infection.
57

Desinfecção de nível intermediário de endoscópio rígido por meio de limpeza prévia com detergente seguido de álcool etílico 70% p/v: protocolo operacional padrão / Disinfection of intermediate level of rigid endoscope through prior cleaning with detergent followed by ethyl alcohol 70% w/v: standard operating protocol

Marco César Jorge dos Santos 11 June 2018 (has links)
INTRODUÇÃO: A limpeza prévia de endoscópios rígidos (ER) seguida de desinfecção de nível intermediário com álcool etílico a 70% p/v após o exame de endoscopia nasal é uma prática adotada em muitos serviços de otorrinolaringologia. A literatura atual, no entanto, recomenda a esterilização ou desinfecção de alto nível como o método de descontaminação mais aceito para produtos para saúde classificados como semicríticos. No entanto, há que se fazer distinção entre equipamentos de alta complexidade e sua invasividade como os endoscópios flexíveis com lumens longos e estreitos utilizados na endoscopia digestiva, daqueles de conformação simples sem lumens de baixa invasividade como os endoscópios rígidos utilizados em otorrinolaringologia. OBJETIVO: Avaliar a segurança da desinfecção de nível intermediário com álcool etílico 70% p/v, após limpeza prévia dos endoscópios rígidos utilizados em procedimentos clínicos de endoscopia nasal considerando a carga microbiológica recuperada após o uso. MÉTODO: Imediatamente após a realização do exame, uma gaze úmida foi utilizada para o arraste da carga biológica do endoscópio rígido, gerando as amostras do Controle Positivo e, após a aplicação do POP, um novo arraste para constituir as amostras do Grupo Experimental. Estas gazes foram inicialmente submetidas à sonicação e agitação imersas em soro fisiológico e em seguida a solução foi submetida a uma técnica de extração de carga microbiológica por filtragem por meio de uma Membrana de Celulose de 0,22um de poro que foi, em seguida, semeada nos meios de ágar Sangue, Chocolate, Sabouraud, Löwenstein-Jensen e Tioglicolato. Estes meios ficaram incubados em estufa a 37ºC ± 2ºC e avaliados, no máximo, até por 60 dias conforme o perfil de crescimento dos diferentes microrganismos de interesse; foram analisados de maneira quantitativa e qualitativa para identificação e classificação dos micro-organismos recuperados após as semeaduras. RESULTADO: Os resultados da análise estatística evidenciaram diferença significativa entre Controle Positivo e Grupo Experimental quando comparados em relação à presença de Streptococcus coagulase negativa (p < 0,001), Bacillus spp (p < 0,001) e Staphylococcus aureus (p=0,001). No Controle Positivo, foram encontradas presença desses micro-organismos respectivamente na seguinte frequência: 63,2%, 28,9% e 28,9%, enquanto que, no Grupo Experimental, não foi houve recuperação microbiana alguma. CONCLUSÃO: Os resultados desta pesquisa demonstram a eficiência, na prática diária, da desinfecção de nível intermediário dos endoscópios utilizados na otorrinolaringologia por meio da fricção com álcool etílico 70% p/v por 90 segundos, com protocolo de limpeza prévia / INTRODUCTION: Prior cleaning of rigid endoscopes (REs) followed by intermediate-level disinfection with 70% ethyl alcohol (w/v) after nasal endoscopy is a common practice in many otolaryngology services. Current literature, in turn, recommends high-level sterilization or disinfection as the most accepted decontamination method for health products classified as semi-critical. However, it is necessary to distinguish highly complex equipment according to their invasiveness, e.g., flexible endoscopes with long and narrow lumens used in digestive endoscopy and those with a simple conformation without lumens of low invasiveness, such as rigid endoscopes used in otorhinolaryngology. OBJECTIVE: To evaluate the safety of intermediate-level disinfection with 70% ethyl alcohol (w/v) after cleaning of REs used in clinical procedures of nasal endoscopy considering the microbiological load recovered after use. METHOD: Immediately after the test, a wet gauze was used to drag the biological load from the RE, generating positive control samples; after applying POP, dragging was carried out again to generate samples of the experimental group. These gasses were initially subjected to sonication and shaking while immersed in physiological saline; the solution was then subjected to the microbiological loading technique by filtration through a 0.22-um pore cellulose membrane and then cultivated on blood, chocolate, Sabouraud, Löwenstein-Jensen, and thioglycolate agar media. These media were incubated at 37ºC ± 2ºC and evaluated for up to 60 days, according to the growth profile of the different microorganisms of interest. A quantitative and qualitative analysis was performed for the identification and classification of microorganisms recovered after cultivation. RESULTS: The results of statistical analysis showed a significant difference between the positive control and experimental groups for the presence of coagulase-negative Streptococcus (p < 0.001), Bacillus spp (p < 0.001), and Staphylococcus aureus (p=0.001). In the positive control group, these microorganisms were found in the following proportions: 63.2%, 28.9%, and 28.9%, respectively, whereas in the experimental group, no microorganisms were recovered. CONCLUSION: The results of this study demonstrate the efficiency of the daily practice of intermediate-level disinfection of endoscopes used in otorhinolaryngology by means of treatment with 70% ethyl alcohol (w/v) for 90 seconds, using a previous cleaning protocol

Page generated in 0.0341 seconds