• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 62
  • 57
  • 14
  • 6
  • 4
  • 3
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 155
  • 81
  • 41
  • 37
  • 36
  • 31
  • 27
  • 26
  • 25
  • 22
  • 21
  • 20
  • 20
  • 19
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Pelletäppan, tennishall med bristfällig konstruktion : En fallstudie av massiv limträkonstruktion

Akhondi, Mehdi January 2014 (has links)
Detta arbete bygger på en jämförelse mellan Boverkets Byggregler och Eurokoder för en befintlig limträkonstruktion. Referensobjektet är en tennishall belägen i Botkyrka kommun. Objektet byggdes under början på 90-talet i form av en treledsram med taktäckning av PVC duk som vilar direkt på limträbalkarna, inklusive en inre duk med mellanliggande isolering och luftspalt. Under de senaste åren har konstruktionen uppvisat tecken på svagheter med bl.a. stora sprickor i limträbalkarna, dessa skador kulminerade i att på begäran av kommunen stänga av anläggningen för fortsatta spel. Oavsett om beräkningarna utförs med BKR eller Eurokoder som är norm idag så har stommen inte tillräckligt bärighet för sin egentyngd och dagens snölast. Detta kan tyckas vara märkligt men förklaringen kan vara att man utförde byggnaden med tanke på att snön glider av hallen och inte ackumuleras. Med detta i åtanke skulle snön glida av om yttertaken hade hållits varm, mycket tyder på att så skulle ha varit fallet om fläktarna som luftar spalten i takkonstruktionen hade varit igång. Enligt Roger Vintemar, verksamhetschef för Idrott och Anläggning på Botkyrka kommun, har fläktaggregatets på/av knapp placerats lättillgängligt i spelargången och det finns anledning att misstänka att fläktaggregatet har varit avstängd vid långa perioder. Sprickorna i bågarna kan bero på överlast eftersom snön har ackumulerats och inte glidit av. Med avseende på hur konstruktionen är utformad och att det har blivit vattenansamlingar på spelbanan är det inte orimligt att ifrågasätta dragstagets rostskydd. Skulle dragstaget som håller ihop de två bågarna brista finns det en överhängande risk för s.k. sprött brott med ett snabbt ras till följd.
22

Cm-faktorer för böjd och tryckt stång : Lösning av nya elementarfall / Cm-factors for flexured and compressed bar : Solution of new elemental cases

Gerland, Jonas January 2018 (has links)
I den mest grundläggande delen av Eurocode 3, SS-EN 1993-1-1, finns olika sätt att kontrollera bärförmågan för en balkpelare som utsätts för böjknäckning, d.v.s. en kombination av transversell och axiell last. Genom att använda formler där det dimensionerande värdet på andra ordningens moment ingår kan man kontrollera om balkpelaren håller för den aktuella belastningen.   Beräkningar av andra ordningens moment ger differentialekvationer som kan vara besvärliga och tidskrävande att lösa, men beräkningarna kan förenklas om man känner till den momentfaktor, kallad Cm-faktor, som tar hänsyn till momentfördelningens form i det aktuella lastfallet.   Denna rapport visar hur man kan härleda både exakta och approximativa värden på Cm-faktorer genom att studera två lastfall som skulle kunna vara av intresse för praktiskt bruk då konsolbalkar utsätts för böjknäckning. Resultaten visar att den approximativa metoden, som innebär avsevärt förenklade beräkningar, ger fullgoda resultat för de två fall som behandlas i rapporten.   Cm-faktorerna presenteras som grafer för att kunna läsas av då normalkraften som angriper i konsolbalkens fria ände varierar. I rapporten ges även bakgrunden till begreppet momentfaktor genom förklaring och beräkning av förstoringsfaktorn, ofta kallad f.
23

Flexural behaviour of asymmetric composite beam with low degree of shear connection

Sheehan, Therese, Dai, Xianghe, Lam, Dennis 24 November 2017 (has links)
Yes / This paper outlines an experiment on a 12 m long composite beam subjected to uniformly distributed loading. Although composite beams are widely used, current Eurocode design guidelines for these types of members can be over-conservative, particularly in relation to the required degree of shear connection. The tested beam comprised a concrete slab supported by profiled metal decking, connected to an asymmetric fabricated steel I-beam using welded shear studs. The specimen was assembled using unpropped construction methods and had a degree of shear connection equal to 33%, significantly lower than the minimum required amount specified in Eurocode 4. A uniformly distributed load was applied to the specimen, which was increased until the failure occurred characterized by yielding of the steel beam. The maximum bending moment of the composite beam obtained from the test was close to the plastic bending resistance according to the Eurocode 4. No concrete crushing or shear stud failure was observed and the end slips exceeded 6 mm, the limit for ductile behaviour in Eurocode 4. The test demonstrated the merits of unpropped construction, which are currently not fully exploited in Eurocode 4. The comparison and analysis suggest that the design limits governing the minimum degree of shear connection might be revised. / RFCS
24

Temperature distribution and charring penetrations in timber assemblies exposed to parametric fire curves : Comparisons between tests and TASEF predictions

Ek, Niklas, Andersson, Isac January 2017 (has links)
Four furnace tests have been performed using two different parametric fire curves and the results are compared with computer simulations and Eurocode calculations. What differentiates the parametric fire curve from other fire curves is in particular the cooling phase, something that has proven to be hard to model for timber structures.   A literature study and computer simulations were followed by experimental work performed at SP Wood Building Technology in Stockholm. The computer simulations were performed using the computer code TASEF. The predictions from TASEF were compared with measurements from the fire tests to evaluate how well the program can predict temperature distribution using a parametric fire curve.   The four fire tests were executed at SP Wood Building Technology, glued laminated timber beams were used in all tests. When preparing the test specimens thermocouples were installed to measure temperature distribution, the thermocouples were installed in drilled holes. A deviation study regarding these drill-holes was performed as a part of the preparations. The temperature distributions measured during the tests were compared with the temperature distribution predicted by TASEF.   Charring rate and charring depth were obtained from the fire tests, from the TASEF simulations but also by using equations given in the Eurocode. Since TASEF simulates temperature distribution and not charring depth, the 300 °C isotherm was assumed to represent the charring depth. The results from all three methods were compared and evaluated.   The agreement between experiments and TASEF predictions regarding temperature distribution and charring depth were in general very good. Parametric fire curves with opening factors of 0.02 m1/2 and 0.04 m1/2 were used in four fire tests. TASEF performed more accurate predictions regarding the temperature distribution for the small opening factor but looking at the charring depth the predictions were better for the bigger opening factor. It is recommended to perform further studies and find out the reason for this behaviour.   Comparing the charring depths measured at the tests with values calculated using Eurocode 5 there were some differences in charring depths. Charring depths for the horizontal direction of the beams were much alike, but when comparing the charring depths for the vertical direction there is a significant difference. The equations regarding charring depth for wood exposed to parametric fire curves in Eurocode 5 underestimate the charring depth. It is recommended to evaluate these equations further.   For one of the timber beams delamination occurred, this has previously been assumed not to occur to glued laminated beams. More studies should be performed regarding delamination of glued laminated beams exposed to fire. / Fyra brandtester i en brandprovningsugn har genomförts med två olika parametriska brandkurvor och resultatet har jämförts med datorsimuleringar och Eurocode-beräkningar. Det som särskiljer parametriska brandkurvor från andra brandkurvor är nedkylningsfasen, något som har visat sig svårt att modellera för träkonstruktioner.   Litteraturstudier och datorsimuleringar följdes av experimentellt arbete som utfördes vid SP Träbyggande och Boende i Stockholm. Datorsimuleringarna har utförts med datorkoden TASEF. Simuleringsresultat från TASEF jämfördes med mätningar från brandtesterna för att utvärdera hur bra TASEF kan förutse temperaturdistributionen då en parametrisk brandkurva används.   De fyra brandtesterna förbereddes och utfördes på SP Träbyggande och Boende, limträbalkar användes i samtliga tester. När testbalkarna förbereddes inför brandtesterna installerades termoelement för att mäta temperaturdistributionen. Termoelementen installerades i borrhål. Som en del av förberedelserna gjordes en avvikelsestudie för dessa borrhål. Temperaturdistributionen som uppmättes under testerna jämfördes med temperaturdistributionen från TASEF-simuleringar.   Från brandtester, TASEF-simuleringar och från ekvationer i Eurocode erhölls förkolningshastighet och förkolningsdjup. Eftersom TASEF simulerar temperaturer och inte förkolningsdjup användes 300 °C isotermen som då antogs representera förkolningsdjupet. Resultatet från alla tre metoder jämfördes och utvärderades.   Generellt stämde temperaturdistributionen och förkolningsdjupen från TASEF-simuleringarna väldigt bra överens med de experimentella resultaten. Under testerna användes parametriska brandkurvor med öppningsfaktorer av 0.02 m1/2 och 0.04 m1/2. TASEF simulerade mer noggranna resultat gällande temperaturdistributionen för kurvan med den lägre öppningsfaktorn medan simuleringar för kurvan med den högre öppningsfaktorn gav bättre resultat för förkolningsdjupet. Det rekommenderas att göra fler studier för att ta reda på anledningen till detta beteende.   Genom att jämföra förkolningsdjup som uppmättes efter brandtesterna med beräknade värden från Eurocode förekom vissa skillnader. Förkolningsdjup för bredden av balkarna var likartade, medan förkolningsdjupet för höjden av balkarna hade en signifikant skillnad. Ekvationerna i Eurocode underskattade förkolningsdjupet, det rekommenderas därför att utvärdera dessa ekvationer ytterligare.   För en av limträbalkarna inträffade delaminering, detta har tidigare antagits vara osannolikt för limträbalkar. Fler studier borde utföras angående delaminering av limträbalkar exponerade för parametriska brandkurvor.
25

Dimensionamento de pilares mistos de aço e concreto. / Design of composite columns of steel and concrete.

Silva, Paulo Henrique Lubas 11 May 2012 (has links)
Os pilares mistos de aço e concreto consistem em um ou mais perfis de aço ligados entre si, trabalhando em conjunto com o concreto, simples ou armado, solicitados à compressão ou à flexocompressão. Os pilares mistos são, basicamente, de dois tipos: revestidos ou preenchidos. O sistema misto apresenta grandes vantagens estruturais, uma vez que herda a capacidade resistente dos pilares de aço e, dos pilares de concreto, sua robustez. Este trabalho estuda o emprego dessa solução de acordo com as principais normas internacionais de dimensionamento à temperatura ambiente, comparando-as entre si e às normas brasileiras. A ABNT NBR 8800:2008, apresenta dois modelos de cálculo simplificados para o dimensionamento de pilares mistos com seções transversais simétricas, com base em duas normas internacionais. O primeiro, o Modelo I, com base no ANSI/AISC 360 (2005) e o segundo, o Modelo II, no Eurocode 4 Part 1-1 (2004). Fica a critério do engenheiro estruturista a escolha do método a ser utilizado. Apresenta-se uma comparação gráfica e tabular da capacidade resistente à temperatura ambiente entre os dois modelos de cálculo da norma brasileira e as normas internacionais. No caso de seções transversais não simétricas, são propostos dois roteiros de dimensionamento inéditos em aplicações de pilares mistos: um com base no Fiber Elemento Method e nas recomendações do Eurocode 4 Part 1-1 (2004), e outro adaptando o primeiro às normas brasileiras. Ambos são avaliados graficamente e por meio de tabelas. Para o auxílio de todos esses estudos, foi utilizado o código CalcPM v1.0, desenvolvido especialmente para esse estudo. / The composite columns have the concrete and the steel profile working together to support loads. The composite columns are basically of two types: encased and filled. The composite system has the advantage to unite the inherent robustness of the concrete columns and high resistance of the steel columns. This work studies the use of this solution according to the main international standards, comparing them with each other and with the Brazilian norms. The Brazilian standard ABNT NBR 8800:2008, presents two simplified models of the composite columns design with symmetrical cross sections, based on two international standards. Model I, based on American standard ANSI/AISC 360 (2005) and Model II, with reference to the European standard Eurocode 4 Part 1-1 (2004). Is up to the engineer to choose the method to be used. It presents a tabular and graphical comparison of the strength between the two calculation models of the Brazilian and international standards. In the case of non-symmetrical cross sections there are two proposed routes unprecedented scale applications of composite columns: one based on \"Fiber Element Method\" and the recommendations of Eurocode 4 Part 1-1 (2004) and another one to adapt the first one to the Brazilian standards. Both are evaluated graphically and by the use of tables. To support all these studies the software CalcPM v1.0 was used and specially developed for this study.
26

Dimensionamento de pilares mistos de aço e concreto. / Design of composite columns of steel and concrete.

Paulo Henrique Lubas Silva 11 May 2012 (has links)
Os pilares mistos de aço e concreto consistem em um ou mais perfis de aço ligados entre si, trabalhando em conjunto com o concreto, simples ou armado, solicitados à compressão ou à flexocompressão. Os pilares mistos são, basicamente, de dois tipos: revestidos ou preenchidos. O sistema misto apresenta grandes vantagens estruturais, uma vez que herda a capacidade resistente dos pilares de aço e, dos pilares de concreto, sua robustez. Este trabalho estuda o emprego dessa solução de acordo com as principais normas internacionais de dimensionamento à temperatura ambiente, comparando-as entre si e às normas brasileiras. A ABNT NBR 8800:2008, apresenta dois modelos de cálculo simplificados para o dimensionamento de pilares mistos com seções transversais simétricas, com base em duas normas internacionais. O primeiro, o Modelo I, com base no ANSI/AISC 360 (2005) e o segundo, o Modelo II, no Eurocode 4 Part 1-1 (2004). Fica a critério do engenheiro estruturista a escolha do método a ser utilizado. Apresenta-se uma comparação gráfica e tabular da capacidade resistente à temperatura ambiente entre os dois modelos de cálculo da norma brasileira e as normas internacionais. No caso de seções transversais não simétricas, são propostos dois roteiros de dimensionamento inéditos em aplicações de pilares mistos: um com base no Fiber Elemento Method e nas recomendações do Eurocode 4 Part 1-1 (2004), e outro adaptando o primeiro às normas brasileiras. Ambos são avaliados graficamente e por meio de tabelas. Para o auxílio de todos esses estudos, foi utilizado o código CalcPM v1.0, desenvolvido especialmente para esse estudo. / The composite columns have the concrete and the steel profile working together to support loads. The composite columns are basically of two types: encased and filled. The composite system has the advantage to unite the inherent robustness of the concrete columns and high resistance of the steel columns. This work studies the use of this solution according to the main international standards, comparing them with each other and with the Brazilian norms. The Brazilian standard ABNT NBR 8800:2008, presents two simplified models of the composite columns design with symmetrical cross sections, based on two international standards. Model I, based on American standard ANSI/AISC 360 (2005) and Model II, with reference to the European standard Eurocode 4 Part 1-1 (2004). Is up to the engineer to choose the method to be used. It presents a tabular and graphical comparison of the strength between the two calculation models of the Brazilian and international standards. In the case of non-symmetrical cross sections there are two proposed routes unprecedented scale applications of composite columns: one based on \"Fiber Element Method\" and the recommendations of Eurocode 4 Part 1-1 (2004) and another one to adapt the first one to the Brazilian standards. Both are evaluated graphically and by the use of tables. To support all these studies the software CalcPM v1.0 was used and specially developed for this study.
27

Stability of Tubular Steel Structures : Buckling and Lateral Torsional Buckling / Stabilité des structures tubulaires en acier : flambement et déversement

Khamisi, Ali 07 December 2016 (has links)
Ce sujet est d’actualité suite à une évolution rapide des types de conception de structures élancées utilisées dans les installations provisoires. C’est seulement depuis une vingtaine d’années que ces structures sont préfabriquées en cadres multidirectionnels (de sections tubulaires en acier ou en aluminium). Ces structures sont légères et leur stabilité réside seulement dans les raideurs internes au niveau des files de montants et au niveau horizontal par les planchers ainsi que dans les liaisons avec l’ouvrage. Ce travail concerne l’étude des instabilités (flambement-déversement) en tenant compte de différents types d’imperfections. De nouvelles courbes de flambement ainsi que les facteurs d’imperfection associés sont proposés dans cette thèse. Ces courbes sont obtenues en imposant une déformée initiale représentant les défauts géométriques et mécaniques (contraintes résiduelles). Les résultats expérimentaux confrontés avec les prévisions théoriques de l’Eurocode 3 montrent que les valeurs des imperfections figurant dans la littérature sont extrêmement exagérées. Les valeurs préconisées dans ce travail pourraient présenter un certain intérêt pour une modification éventuelle des courbes européennes de flambement pour ce type de structure. En ce qui concerne l’instabilité latérale, une méthodologie originale d’essais en vraie grandeur de poutres à treillis formés d’éléments tubulaires a été également mise au point. Le système de chargement à « roues libres » développé permet de libérer le point d’application de l’effort dès le début de l’instabilité. Cette technique conduit à des mesures plus précises du moment critique de déversement. / This subject becomes topical following a rapid evolution of design procedures for slender structures used widely in the temporary installations. Only through the last twenty years that these structures are prefabricated of multidirectional frames (steel or aluminium tubular sections). These structures are lightweight and their stability lies only in the internal stiffness at rows of posts and horizontally by the planking as well as the links with the building. This work concerns the study of instabilities (buckling - lateral torsional buckling) taking into account different types of imperfections. New buckling curves and the associated imperfection factors are proposed in this thesis. These curves are obtained by imposing an initial deformed representing the geometrical and mechanical defects (residual stress). The experimental results were confronted with theoretical predictions of Eurocode 3 which show that the values of the imperfections in the literature are extremely exaggerated. The values advocated in this work could be of interest for a possible adjustment of the European buckling curves for this type of structure. Regarding the lateral instability, an original methodology in real scale tests of trusses consist of tubular elements was also developed. The developed loading system of "free wheels" allows releasing the point of application of the force from the beginning of instability. This technique leads to more accurate measurements of the critical lateral torsional buckling moment.
28

Calculation program for timber connections / Dimensioneringshjälpmedel för träinfästningar

Krepper, Martin, Reutermo, Anders January 2016 (has links)
Vi har skapat ett hjälpmedel som dimensionerar träbalk och infästningarna balksko och spikningsplåt, enligt eurokoderna. Det är programmerat i Visual-Basic och har ett enkelt användargränssnitt.
29

Brandpåverkan på samverkanskonstruktion : En utvärdering av betongfylld stålprofil

Andersson, Marcus, Lundberg, Michael January 2014 (has links)
En samverkanspelare drar nytta av interaktionen mellan det omslutande stålröret och profilens betongkärna för att därav erhålla en ökad lastkapacitet. För att förstå beteendet och effekterna av interaktionen mellan stål och betong är det viktigt att förstå de enskilda materialens beteende. Betongens huvudsakliga uppgift i en samverkanspelare är att ta upp tryckkrafter medan stålets främsta uppgift är att motverka momentpåkänning och uppta dragkrafter. I normal rumstemperatur samverkar stål och betong för att bära den aktuella lasten. Samverkanspelaren har stor potential med avseende på lastkapacitet. Nedan tas några av de förväntade positiva effekterna av interaktionen mellan stål och betong upp: Förekomsten av buckling för stålet försenas samtidigt som den försämrade bärförmågan efter lokal buckling uppstått dämpas, beroende på betongkärnans återhållande effekt. Förhindrar spjälkning och hållfasthetsnedsättningen för betongen blir inte lika drastisk. Ökad tryckhållfasthet och deformations kapacitet, speciellt för grövre tvärsnitt. Vid ett brandscenario utsätts pelaren för en temperaturhöjning. Värmeöverföringen från brandgaserna till pelaren sker främst genom strålnings- och konvektionsvärme. Lastkapaciteten för pelarens ingående material kommer att reduceras till följd av denna värmeökning. Storleken för reduceringen beror på hur hög temperatur materialen utsätts för, där en högre temperatur medför en kraftigare reducering. För den betongfyllda stålprofilen kommer således det omkringliggande stålet att fort bli mycket varmt medan betongkärnan erhåller en trögare temperaturökning. I brandfallets initialskede expanderar stålet hastigare än betongen, vilket medför att stålet då i princip bär hela den aktuella lasten. Efter en tid förmår inte stålet längre att vara lastbärare och betongkärnan bär då istället lasten. Pelarens slutliga kollaps sker först då betongkärnan slutligen inte förmår belastningen. En jämförande teoretisk undersökning av samverkans-, betong- och stålpelare under termisk påverkan genomfördes i detta arbete. Beräkningsgången följer de dimensioneringsregler som finns för respektive material i Eurocodes. Kapacitetsberäkningar är gjorda för både normal rumstemperatur likväl som för brandutsatthet. För analys och bestämning av pelartvärsnittens temperaturprofil vid de olika tidsstegen 30, 60 och 90 minuter användes ett nominellt brandförlopp. Tvärsnittens temperaturhistoria användes sedan för att reducera de mekaniska egenskaperna som funktion av temperaturen.Undersökningen konstaterade att samverkans- och betongpelarens kapacitet vid 60 minuters brandpåverkan var tillräcklig. Hand- och datorberäkningar påvisade nästintill likvärdig lastkapacitet vid termisk påverkan och normaltemperatur. / A concrete-filled steel column is taking advantage of the interaction between the enclosing steel profile and the concrete core to obtain an increased load capacity. In order to understand the behavior and effects of the interaction between steel and concrete, it is important to first understand the individual material behavior. The main task of the concrete in a composite column is to absorb pressure forces while the steel's main task is to counteract stress and the tensile forces. At normal room temperature both steel and concrete interact to carry the current load. Concrete-filled steel column has a great potential according to load capacity. Some of the expected positive effects of the interaction between steel and concrete are: The occurrence of buckling for the steel is delayed and the strength deterioration after the local buckling is moderate, both due to the restraining effect of concrete. Prevents the concrete spalling and strength reduction of concrete core will not be as drastic. Increased compressive strength and deformation capacity, especially for large-diameter cross-section. In a fire scenario the column is exposed to a temperature increase. Heat transfer from the combustion gases to the column occurs mainly through radiation and convection heat. The load carrying capacity of the included materials will be reduced as a result of this heat transfer. The size of the reduction depends on how high temperature the materials are exposed to, where a higher temperature leads to a greater reduction. For the concrete-filled steel column, the surrounding steel profile will quickly become very hot while the concrete core obtains a slower rise in temperature. In the initial stage of the fire case the steel expands faster than the concrete, causing the steel to then basically carry the entire load of the column. After some time the steel will be incapable of carrying the load, then instead the concrete core will be the main load carrier. The final collapse of the column occurs only when the concrete core finally will be incapable to carry the load. A comparative theoretical study of concrete-filled steel column, concrete- and steel columns under thermal effects was carried out in this work. The calculation method followed the design rules that exist for each material in the Eurocode. Column capacity calculations are made for both normal room temperatures as well as for fire exposure. The ISO-standard fire curve was used for analysis and determination of each column cross-section temperature profile at the different time stages 30, 60 and 90 minutes. The mechanical properties were then reduced as a function of the temperature. The survey found that the composite and concrete column load capacity exposed to 60 minutes of the ISO-standard fire curve was adequate. Calculations made by hand and with computer showed almost equivalent load capacity by thermal effects and normal temperature.
30

Temperature distribution and charring penetrations in timber assemblies exposed to parametric fire curves : Comparisons between tests and TASEF predictions

Andersson, Isac, Ek, Niklas January 2017 (has links)
Four furnace tests have been performed using two different parametric fire curves and the results are compared with computer simulations and Eurocode calculations. What differentiates the parametric fire curve from other fire curves is in particular the cooling phase, something that has proven to be hard to model for timber structures. A literature study and computer simulations were followed by experimental work performed at SP Wood Building Technology in Stockholm. The computer simulations were performed using the computer code TASEF. The predictions from TASEF were compared with measurements from the fire tests to evaluate how well the program can predict temperature distribution using a parametric fire curve. The four fire tests were executed at SP Wood Building Technology, glued laminated timber beams were used in all tests. When preparing the test specimens thermocouples were installed to measure temperature distribution, the thermocouples were installed in drilled holes. A deviation study regarding these drill-holes was performed as a part of the preparations. The temperature distributions measured during the tests were compared with the temperature distribution predicted by TASEF. Charring rate and charring depth were obtained from the fire tests, from the TASEF simulations but also by using equations given in the Eurocode. Since TASEF simulates temperature distribution and not charring depth, the 300 °C isotherm was assumed to represent the charring depth. The results from all three methods were compared and evaluated. The agreement between experiments and TASEF predictions regarding temperature distribution and charring depth were in general very good. Parametric fire curves with opening factors of 0.02 m1/2 and 0.04 m1/2 were used in four fire tests. TASEF performed more accurate predictions regarding the temperature distribution for the small opening factor but looking at the charring depth the predictions were better for the bigger opening factor. It is recommended to perform further studies and find out the reason for this behaviour. Comparing the charring depths measured at the tests with values calculated using Eurocode 5 there were some differences in charring depths. Charring depths for the horizontal direction of the beams were much alike, but when comparing the charring depths for the vertical direction there is a significant difference. The equations regarding charring depth for wood exposed to parametric fire curves in Eurocode 5 underestimate the charring depth. It is recommended to evaluate these equations further. For one of the timber beams delamination occurred, this has previously been assumed not to occur to glued laminated beams. More studies should be performed regarding delamination of glued laminated beams exposed to fire. / Fyra brandtester i en brandprovningsugn har genomförts med två olika parametriska brandkurvor och resultatet har jämförts med datorsimuleringar och Eurocode-beräkningar. Det som särskiljer parametriska brandkurvor från andra brandkurvor är nedkylningsfasen, något som har visat sig svårt att modellera för träkonstruktioner. Litteraturstudier och datorsimuleringar följdes av experimentellt arbete som utfördes vid SP Träbyggande och Boende i Stockholm. Datorsimuleringarna har utförts med datorkoden TASEF. Simuleringsresultat från TASEF jämfördes med mätningar från brandtesterna för att utvärdera hur bra TASEF kan förutse temperaturdistributionen då en parametrisk brandkurva används. De fyra brandtesterna förbereddes och utfördes på SP Träbyggande och Boende, limträbalkar användes i samtliga tester. När testbalkarna förbereddes inför brandtesterna installerades termoelement för att mäta temperaturdistributionen. Termoelementen installerades i borrhål. Som en del av förberedelserna gjordes en avvikelsestudie för dessa borrhål. Temperaturdistributionen som uppmättes under testerna jämfördes med temperaturdistributionen från TASEF-simuleringar. Från brandtester, TASEF-simuleringar och från ekvationer i Eurocode erhölls förkolningshastighet och förkolningsdjup. Eftersom TASEF simulerar temperaturer och inte förkolningsdjup användes 300 °C isotermen som då antogs representera förkolningsdjupet. Resultatet från alla tre metoder jämfördes och utvärderades. Generellt stämde temperaturdistributionen och förkolningsdjupen från TASEF-simuleringarna väldigt bra överens med de experimentella resultaten. Under testerna användes parametriska brandkurvor med öppningsfaktorer av 0.02 m1/2 och 0.04 m1/2. TASEF simulerade mer noggranna resultat gällande temperaturdistributionen för kurvan med den lägre öppningsfaktorn medan simuleringar för kurvan med den högre öppningsfaktorn gav bättre resultat för förkolningsdjupet. Det rekommenderas att göra fler studier för att ta reda på anledningen till detta beteende. Genom att jämföra förkolningsdjup som uppmättes efter brandtesterna med beräknade värden från Eurocode förekom vissa skillnader. Förkolningsdjup för bredden av balkarna var likartade, medan förkolningsdjupet för höjden av balkarna hade en signifikant skillnad. Ekvationerna i Eurocode underskattade förkolningsdjupet, det rekommenderas därför att utvärdera dessa ekvationer ytterligare. För en av limträbalkarna inträffade delaminering, detta har tidigare antagits vara osannolikt för limträbalkar. Fler studier borde utföras angående delaminering av limträbalkar exponerade för parametriska brandkurvor.

Page generated in 0.0321 seconds