• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 102
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 102
  • 102
  • 26
  • 25
  • 24
  • 19
  • 18
  • 13
  • 10
  • 10
  • 10
  • 9
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Quantificação à beira do leito do potencial de recrutamento alveolar através da tomografia de impedância elétrica em modelo experimental síndrome do desconforto respiratório agudo / Bedside quantification of alveolar recruitment potential using electrical impedance tomography in an experimental model of acute respiratory distress syndrome

Santiago, Roberta Ribeiro de Santis 19 January 2016 (has links)
Introdução: A síndrome do desconforto respiratório agudo (SDRA) tem como parte do seu tratamento uma ventilação mecânica adequada. A manobra de recrutamento alveolar (MRA) faz parte de um grupo de estratégias empregadas nos quadros moderados e graves. A MRA consiste na aplicação de um aumento de pressão transitório e controlado nas vias aéreas no intuito de abrir alvéolos previamente colapsados. A Tomografia de Impedância Elétrica (TIE) é capaz de avaliar o potencial de recrutamento alveolar (PRA) a beira leito. Objetivos:1) Comparar o PRA calculado pela TIE (através do ganho de complacência regional) com a TC. 2) Avaliar o \"deslocamento vertical de volume\" como índice de recrutamento alveolar.3) Estimar precocemente o PRA, através das manobras de recrutamento de rastreio propostas, utilizando a TIE. Método: Avaliamos o PRA em um modelo experimental de SDRA. Utilizamos 15 suínos da raça Landrace. Os animais foram sedados e intubados, em seguida, submetidos ao modelo experimental de SDRA desenvolvido na Faculdade de Medicina da Universidade de São Paulo (LIM-09). Ao término da lesão, um grupo de 7 animais recebeu uma sequência randomizada de manobras de recrutamento de rastreio propostas (Pressões inspiratórias de 30, 35 e 40 cmH2O) seguidas da manobra de recrutamento máxima (Pressão inspiratória de 60 cmH2O). Os animais foram monitorados com TIE e Tomografia computadorizada por raio X (TC) durante todas as manobras de recrutamento. Outro grupo de 8 animais ,submetidos a mesma lesão e com medidas de TC e TIE, foi retirado do banco de dados do LIM-09 e também analisados. Utilizamos o programa IBM® SPSS® Statistics 9.0 e 20.0.Resultados:1) PRA calculado pela TIE atráves do ganho de complacência regional corrigido para hiperdistensão, comparado com TC, apresentou um R2=0,76. 2) PRA calculado pelo ganho de complacência regional corrigido para hiperdistensão combinado com o deslocamento vertical apresentou R2 = 0,91 comparado a TC .3) As manobras de rastreio não conseguiram predizer quantitativamente o PRA mas auxiliariam na correção da hiperdistensão. Conclusões: A TIE é capaz de avaliar o recrutamento alveolar a beira leito. O deslocamento vertical combinado com o ganho de complacência regional corrigida para hiperdistensão representam de forma semelhante a TC o comportamento pulmonar durante uma MRA. A aplicação de uma manobra de recrutamento de rastreio pode ser útil para uma manobra de recrutamento máxima mais segura / Introduction: The acute respiratory distress syndrome (ARDS) treatment demands a proper mechanical ventilation strategy. The alveolar recruitment maneuver (ARM) is an intervention applied in moderate and severe cases of ARDS. ARM is a transitory and controlled increase in mechanical ventilator pressure delivered to the lungs aiming to open previously collapsed alveoli. The electrical impedance tomography (EIT) is a valuable tool at bedside; it is able to monitor and to help during an ARM performance through the estimation of the alveolar recruitment potential (ARP). Objectives: 1) To compare the ARP with the EIT as a regional compliance improvement quantification adjusted for lung hyperdistention with CT. 2) To evaluate the \"volume vertical displacement\" at the same pressure as alveolar recruitment index using EIT and CT. 3) To estimate earlier the ARP using the EIT through a screening recruitment maneuver. Methods: We evaluated the ARP in an experimental model of ARDS. We studied 15 Landrace race pigs. Subjects were sedated, intubated and submitted to the ARDS experimental model developed at Medical investigation laboratory n ° 09, University of São Paulo. In the end of the lung injury, a group of 7 pigs received a randomized sequence of screening recruitment maneuvers (inspiratory pressures of 30, 35 and 40 cmH2O) followed by a maximum recruitment maneuver (inspiratory pressure of 60 cmH2O).EIT and x-ray computed tomography (CT) monitored the steps of each recruitment maneuver. Another group of 8 pigs, submitted to the same lesion and with measures of EIT and CT, were extracted from our data bank. Analysis was performed at IBM® SPSS® Statistics 20.0. Results: 1) ARP calculated by EIT (regional compliance improvement quantification) reached a R2=0,76 when compared to CT. 2) The combination of regional compliance improvement and volume vertical displacement obtained R2 = 0,91 when compared to CT 3) The screening recruitment maneuvers were not able to predict quantitatively the ARP, but they helped in the lung hyperdistension adjustment. Conclusions: EIT is able to evaluate the ARP at bedside. The combination of regional compliance improvement and volume vertical displacement give information similar to CT about the lung behavior during a ARM. The application of a recruitment screening maneuver might be useful for more safe ARM
92

Efeitos interativos da pressão expiratória final positiva (PEEP) e da fração inspirada de oxigênio (FIO2) no colapso pulmonar durante anestesia geral em modelo experimental suíno / Interactive effects of positive-end expiratory pressure (PEEP) and fraction of inspired oxygen (FIO2) on pulmonary collapse during general anesthesia in experimental swine model

Melo, José Renato de 25 October 2017 (has links)
INTRODUÇÃO: O desenvolvimento de colapso pulmonar (atelectasia) durante anestesia geral com ventilação mecânica é frequente, podendo determinar hipoxemia e contribuir para desenvolvimento de outras complicações pós-operatórias, como infecção e síndrome do desconforto respiratório agudo (SDRA). O uso de fração inspirada de oxigênio (FIO2) baixa e de pressão expiratória final positiva (PEEP) podem reduzir a quantidade de pulmão atelectasiado. Existem poucos dados experimentais sobre a cinética do desenvolvimento da atelectasia no intraoperatório em diferentes ajustes de FIO2 e PEEP no decorrer do tempo. A Tomografia de impedância elétrica (TIE) do tórax permite uma análise contínua e não invasiva da função pulmonar, bem como da quantificação do colapso e pode ser usada no intraoperatório. OBJETIVOS: a) avaliar, em animais com pulmões sadios durante anestesia geral, o efeito do uso de uma PEEP individualizada escolhida através da TIE (\"PEEP titulada\"), na formação de colapso; b) analisar a magnitude e a cinética de desenvolvimento do colapso pulmonar no decorrer do período de uma hora em dois valores de FIO2 (0,4 e 1) e dois valores de PEEP (3 cmH2O e valor da PEEP titulada) através da TIE e Tomografia computadorizada (TC); c) analisar mecânica, ventilação regional e aeração pela TIE e troca gasosa nos diferentes períodos do estudo. MÉTODOS: Nove animais (suínos) com pulmão normal foram submetidos à manobra de titulação da PEEP para escolha da PEEP que determina colapso pulmonar mínimo (colapso menor que 3% determinado pela TIE, denominada \"PEEP titulada\") e posteriormente ventilados com volume corrente de 6ml/Kg em quatro ajustes, em sequência randomizada, por um período de 1 hora: FIO2 0,4 e PEEP 3, FIO2 0,4 e PEEP titulada, FIO2 1 e PEEP 3 e FIO2 1 e PEEP titulada. O colapso, ventilação regional e aeração foram medidos continuamente, através da TIE assim como dados da mecânica. Mensuramos troca gasosa e aeração pulmonar pela TC em 3 momentos em cada período do estudo (baseline, 5 e 50 minutos). RESULTADOS: A PEEP titulada foi de 11,6 ±1,4 cm H2O. Houve colapso progressivo no decorrer do tempo nos 4 grupos estudados tendo sido maior na PEEP 3 que na PEEP titulada. A medida do colapso pela TIE não foi influenciada pela FIO2 utilizada, ao contrário da mensuração pela TC na qual o colapso foi maior na FIO2 de 1. Houve queda da complacência pulmonar e aumento da pressão de distensão no decorrer do tempo, maiores na PEEP 3, sem influência da FIO2. Na região dorsal, a TIE evidenciou redução da ventilação (delta Z) na PEEP 3, sem influência da FIO2, e, também, redução da aeração (mínimo Z) que foi maior na PEEP 3 e na FIO2 de 1. Houve queda da relação PaO2/FIO2 e aumento do shunt e mistura venosa na PEEP 3. Não houve alterações hemodinâmicas clinicamente relevantes durante o estudo. CONCLUSÕES: Houve colapso progressivo no decorrer do tempo, sendo maior na PEEP 3 que na PEEP titulada. O colapso aferido pela TC foi maior na FIO2 de 1 do que na 0,4 para uma mesma PEEP, diferente da TIE cuja estimativa de colapso não foi diferente. Paralelamente houve queda da complacência pulmonar, aumento da pressão de distensão e redução da ventilação dorsal, maiores na PEEP 3 e sem influência da FIO2. A queda da aeração estimada pela TIE foi maior na PEEP 3, sendo que nas duas PEEP a aeração foi menor na FIO2 de 1 / INTRODUCTION: The development of pulmonary collapse (atelectasis) during general anesthesia with mechanical ventilation is frequent, which can determine hypoxemia and contribute to the development of other postoperative complications, such as infection and acute respiratory distress syndrome (ARDS). The use of low fraction of inspired oxygen (FIO2) and positive end expiratory pressure (PEEP) may reduce the amount of collapsed lung. There are few experimental data on the kinetics of intraoperative atelectasis development in different FIO2 and PEEP adjustments over time. Electrical impedance tomography (EIT) of the thorax allows a continuous and noninvasive analysis of pulmonary function as well as the quantification of pulmonary atelectasis and can be used intraoperatively. OBJECTIVES: a) to evaluate, in animals with healthy lungs during general anesthesia, the effect of the use of an individualized PEEP chosen through EIT (titrated PEEP), in the formation of collapse; b) to analyze the magnitude and development kinetics of pulmonary collapse during the one-hour period in two values of FIO2 (0.4 and 1) and two PEEP values (3 cmH2O and titrated PEEP value) through EIT and computed tomography (CT); c) to analyze mechanics, regional ventilation and aeration by EIT and gas exchange in the different periods of the study. METHODS: Nine animals (swine) with normal lung were submitted to a PEEP titration maneuver to select PEEP that determines minimal pulmonary collapse (collapse of less than 3% determined by EIT, called \"titrated PEEP\") and then ventilated with a tidal volume of 6ml / kg in four adjustments, in a randomized sequence, for a period of 1 hour: FIO2 0.4 and PEEP 3, FIO2 0.4 and titrated PEEP, FIO2 1 and PEEP 3 and FIO2 1 and titrated PEEP. The collapse, regional ventilation and aeration were measured continuously through EIT as well as mechanics data. We also measured gas exchange and aeration by CT at 3 times in each study period (baseline, 5 e 50 minutes). RESULTS: The titrated PEEP was 11.6 ±1.4 cm H2O. There was a progressive collapse over time in the 4 groups studied, having been higher in PEEP 3 than in titrated PEEP. The measurement of EIT collapse was not influenced by the FIO2 used, as opposed to the CT measurement in which the collapse was greater in the FIO2 1. There was a decrease in pulmonary compliance and an increase in drive pressure over time, higher in PEEP 3, without influence of FIO2. In the dorsal region, EIT showed a decrease in ventilation, as measured by delta Z, in PEEP 3, with no influence of FIO2; there was also reduction of aeration, measured by the minimum Z, higher in PEEP 3 and FIO2 of 1. There was a decrease in the PaO2 / FIO2 ratio and increased in shunt and venous admixture in PEEP 3. There was no clinically relevant change in hemodynamics during the study. CONCLUSIONS: There was a greater collapse in PEEP 3 than in titrated PEEP over time. Collapse measured by CT was higher in FIO2 of 1 than 0.4 for the same PEEP, different from EIT estimates of collapse which was not different. Beside the collapse, there were decrease in compliance, increase in driving pressure and reduction of dorsal ventilation, higher in PEEP 3 without FIO2 influence. The decrease of aeration estimated by EIT was higher in PEEP 3 and for both PEEP values aeration was lower with FIO2 of 1
93

Novo método de hipotermia encefálica exclusiva através de resfriamento nasofaríngeo: modelo experimental em suínos / New method of exclusive brain hypothermia by means of nasopharyngeal cooling: swine experimental study

Paiva, Bernardo Lembo Conde de 20 October 2014 (has links)
INTRODUÇÃO: Evidências relevantes acerca dos benefícios da hipotermia terapêutica provieram da utilização de técnicas de resfriamento sistêmico. Essas técnicas, no entanto, podem causar complicações graves que poderiam ser evitadas com métodos de hipotermia encefálica seletiva. O presente estudo objetiva: 1) verificar a viabilidade da hipotermia encefálica exclusiva através de um sistema de resfriamento nasofaríngeo concomitante ao de preservação da temperatura corpórea em suínos e 2) investigar os efeitos da hipotermia encefálica exclusiva nas variáveis fisiológicas sistêmicas e encefálicas. MÉTODOS: Dez suínos híbridos foram submetidos a resfriamento nasofaríngeo durante 60 minutos e subsequente reaquecimento espontâneo. Foram obtidos dados referentes a: pressão arterial média, débito cardíaco, temperatura encefálica, pressão parcial de oxigênio do tecido encefálico (PbtO2, do inglês, pressure of brain tissue O2), velocidade do fluxo sanguíneo nas artérias encefálicas, índice de resistência e índice de pulsatilidade. RESULTADOS: O resfriamento nasofaríngeo associou-se à um decréscimo gradual da temperatura encefálica, que foi mais marcante no hemisfério cerebral esquerdo (p < 0,01). Neste hemisfério, houve redução de 1,47 ± 0,86°C nos primeiros 5 minutos (p < 0,01), 2,45 ± 1,03°C aos 10 minutos e 4,45 ± 1,36°C após 1 hora (p < 0,01). A diferença entre as temperaturas cerebral sistêmica foi 4,57 ± 0,87°C (p < 0,01). As temperaturas centrais (retal, esofágica e da artéria pulmonar), assim como a hemodinâmica encefálica e sistêmica, mantiveram-se estáveis durante o procedimento. Houve diminuição significativa da PbtO2, concomitantemente ao decréscimo da temperatura encefálica. CONCLUSÕES: A indução de hipotermia encefálica exclusiva é possível através de resfriamento nasofaríngeo associado a medidas de preservação da temperatura sistêmica. O resfriamento encefálico exclusivo não influencia as funções hemodinâmicas sistêmicas e encefálicas, contudo reduz significativamente a PbtO2 / INTRODUCTION: Relevant evidences for the use of therapeutic hypothermia derive from studies using whole body cooling methods. These methods can lead to serious complications. To avoid such complications, selective brain cooling methods were developed. The objective of this study was: 1) to verify the feasibility of exclusive brain hypothermia by means of nasopharyngeal cooling along with measures of systemic temperature preservation in an experimental swine model, and 2) to investigate the influence of the exclusive brain cooling on cerebral and systemic hemodynamics as well as on cerebral oxygenation. METHODS: Ten hybrid swine underwent nasopharyngeal cooling for 60 minutes, followed by spontaneous rewarming. A number of physiological variables were monitored: arterial blood pressure, cardiac output, temperature in the right and left cerebral hemispheres, pressure of brain tissue O2, cerebral blood flow velocities, resistance index, and pulsatility index. RESULTS: Nasopharyngeal cooling was associated with decrease in brain temperature, which was more significant in the left cerebral hemisphere (p < 0,01). There was a reduction of 1.47 ± 0.86°C in the first 5 minutes (p < 0.01), 2.45 ± 1.03°C within 10 min, and 4.45 ± 1.36°C after 1 hour (p < 0.01). The brain-core gradient was 4.57 ± 0.87°C (p < 0,001). Rectal, esophageal, and pulmonary artery temperatures, as well as brain and systemic hemodynamics, remained stable during the procedure. PbtO2 values significantly decreased following the brain cooling. CONCLUSION: Achievement of exclusive brain hypothermia is feasible by means of nasopharyngeal cooling associated with measures of systemic temperature preservation. Selective brain cooling does not influence both systemic and cerebral hemodynamics, except PbtO2, which decreased significantly
94

Titulação de PEEP por manobra rápida versus lenta utilizando tomografia de impedância elétrica, e estabilidade da função pulmonar com estratégia ventilatória protetora em modelo suíno de síndrome do desconforto respiratório agudo / PEEP titration guided by Electrical impedance tomography by fast and slow maneuver and pulmonary stability with protective mechanical ventilation strategy in a swine mode of Acute Respiratory Distress Sindrome

Ortiz, Tatiana de Arruda 26 July 2017 (has links)
Introdução: A estratégia protetora de ventilação mecânica para a Síndrome do Desconforto Respiratório Agudo (SDRA), que associa o uso de baixo volume corrente com PEEP mais elevada, é uma intervenção eficaz para reduzir a morbimortalidade desta síndrome. Existe um consenso sobre o ajuste do volume corrente, mas o método de escolher a PEEP ainda é controverso. Dos diversos modos de escolher a PEEP, a titulação decrescente, após uma manobra de recrutamento alveolar, é um método com base fisiológica bem aceito. A escolha da PEEP é feita com base na complacência do sistema respiratório ou métodos de imagem que avaliam o colapso pulmonar. Esta titulação geralmente é feita de modo lento (4-10 minutos por queda de PEEP) o que a torna difícil na prática clínica e aumenta o risco para o paciente. Além disso, os critérios para escolha do valor da PEEP que mantém a estabilidade pulmonar ao longo do tempo ainda são incertos. Objetivos: 1) comparar, em modelo suíno de SDRA grave, usando a Tomografia de Impedância Elétrica (TIE) e a Tomografia Computadorizada (TC), o ajuste de PEEP por titulação decrescente de forma convencional (32 minutos) e rápida (6 minutos); e 2) avaliar a estabilidade pulmonar e hemodinâmica (complacência do sistema respiratório, shunt, PaO2 e débito cardíaco) durante 1 hora de ventilação mecânica com 3 níveis de PEEP definidos pela TIE: PEEP inferior à 1% de colapso de tecido pulmonar (PEEP TIT); inferior à 1% de colapso de tecido pulmonar +2cm H2O (PEEP TIT+2) e inferior à 1% de colapso de tecido pulmonar - 2cmH2O (PEEP TIT -2). Método: Vinte e cinco animais foram estudados, sendo que 6 também realizaram TC e 11 animais foram acompanhados ao longo do tempo. Resultados: Não foi observada diferença na porcentagem de colapso encontrado pelos dois métodos de imagem (TC e TIE), tanto na titulação rápida (p=0,89) como na lenta (p=0,86). Houve uma boa concordância entre as titulações rápida e lenta realizadas pela TIE, com diferença entre as titulações lenta e rápida de -0,6 (± 1,2) cmH2O. A PaCO2 foi significantemente maior (p=0,01) na titulação lenta quando comparado com a rápida. No seguimento por 1 hora, a estratégia PEEP TIT-2 determinou menores valores de complacência (p < 0,001), menor PaO2 (p=0,001) e maior porcentagem de shunt (p < 0,01) quando comparado com as estratégias PEEP TIT e PEEP TIT+2. Conclusões: a titulação rápida teve boa concordância com titulação lenta e determinou menos hipercapnia; 2) a PEEP ótima escolhida por titulação rápida utilizando TIE (colapso recrutável inferior a 1%) conseguiu manter boa estabilidade pulmonar e oxigenação durante 1 hora de monitorização; 3) não houve diferença entre o colapso recrutável estimado pelo TIE e pela TC dinâmica / Introduction: The protective strategy of mechanical ventilation for Acute Respiratory Distress Syndrome (ARDS), which combines low tidal volume with higher PEEP, is an effective intervention to reduce the morbimortality of this syndrome. There is a consensus about setting tidal volume, but the method of choosing PEEP is still controversial. Decremental PEEP titration, following an alveolar recruitment maneuver, is a well-accepted method with physiological basis. The choice of PEEP is based on respiratory system complacency or imaging methods that assess lung collapse. This titration is usually done slowly (4-10 minutes in each step) which makes its execution difficult in clinical practice and increases the risk for the patient. In addition, the criteria for choosing the value of PEEP that maintains pulmonary stability over time are still uncertain. Objectives: 1) to compare, in a severe ARDS model in pigs, using Electrical Impedance Tomography (EIT) and Computed Tomography (CT), the decremental PEEP titration in a conventional maneuver (slow, 32 minutes) and fast (6 minutes); and 2) to evaluate the pulmonary stability and hemodynamics (respiratory system compliance, shunt, PaO2 and cardiac output) during 1 hour of mechanical ventilation with 3 PEEP values defined by EIT: PEEP with less than 1% lung tissue collapse (PEEP TIT); less than 1% collapse of lung tissue + 2cm H2O (PEEP TIT + 2) and less than 1% collapse of lung tissue - 2cmH2O (PEEP TIT - 2). Methods: Twenty-five animals were studied, 6 of which also performed CT and 11 animals were monitored over time. Results: No difference was observed in the percentage of collapse found by the two imaging methods (CT and EIT), both in fast (p = 0.89) and slow (p = 0.86) titrations. There was a good concordance between the fast and slow titrations performed by EIT, with a difference between the slow and fast titrations of -0.6 (± 1.2) cmH2O. PaCO2 was significantly higher (p = 0.01) in slow titration than in fast titration. At the 1-hour follow-up, the PEEP TIT-2 strategy determined lower values of compliance (p < 0.001), lower PaO2 (p = 0.001) and higher shunt (p < 0,01) when compared with PEEP TIT and PEEP TIT +2 strategies. Conclusions: 1) fast titration had good agreement with slow titration and causes less hypercapnia; 2) optimum PEEP chose by fast titration using EIT (recruitable-collapse lower than 1%) was able to maintain good lung function and oxygenation during 1 hour of monitoring; 3) there was no difference between the recruitable collapse estimated by EIT and by dynamic CT
95

Titulação de PEEP por manobra rápida versus lenta utilizando tomografia de impedância elétrica, e estabilidade da função pulmonar com estratégia ventilatória protetora em modelo suíno de síndrome do desconforto respiratório agudo / PEEP titration guided by Electrical impedance tomography by fast and slow maneuver and pulmonary stability with protective mechanical ventilation strategy in a swine mode of Acute Respiratory Distress Sindrome

Tatiana de Arruda Ortiz 26 July 2017 (has links)
Introdução: A estratégia protetora de ventilação mecânica para a Síndrome do Desconforto Respiratório Agudo (SDRA), que associa o uso de baixo volume corrente com PEEP mais elevada, é uma intervenção eficaz para reduzir a morbimortalidade desta síndrome. Existe um consenso sobre o ajuste do volume corrente, mas o método de escolher a PEEP ainda é controverso. Dos diversos modos de escolher a PEEP, a titulação decrescente, após uma manobra de recrutamento alveolar, é um método com base fisiológica bem aceito. A escolha da PEEP é feita com base na complacência do sistema respiratório ou métodos de imagem que avaliam o colapso pulmonar. Esta titulação geralmente é feita de modo lento (4-10 minutos por queda de PEEP) o que a torna difícil na prática clínica e aumenta o risco para o paciente. Além disso, os critérios para escolha do valor da PEEP que mantém a estabilidade pulmonar ao longo do tempo ainda são incertos. Objetivos: 1) comparar, em modelo suíno de SDRA grave, usando a Tomografia de Impedância Elétrica (TIE) e a Tomografia Computadorizada (TC), o ajuste de PEEP por titulação decrescente de forma convencional (32 minutos) e rápida (6 minutos); e 2) avaliar a estabilidade pulmonar e hemodinâmica (complacência do sistema respiratório, shunt, PaO2 e débito cardíaco) durante 1 hora de ventilação mecânica com 3 níveis de PEEP definidos pela TIE: PEEP inferior à 1% de colapso de tecido pulmonar (PEEP TIT); inferior à 1% de colapso de tecido pulmonar +2cm H2O (PEEP TIT+2) e inferior à 1% de colapso de tecido pulmonar - 2cmH2O (PEEP TIT -2). Método: Vinte e cinco animais foram estudados, sendo que 6 também realizaram TC e 11 animais foram acompanhados ao longo do tempo. Resultados: Não foi observada diferença na porcentagem de colapso encontrado pelos dois métodos de imagem (TC e TIE), tanto na titulação rápida (p=0,89) como na lenta (p=0,86). Houve uma boa concordância entre as titulações rápida e lenta realizadas pela TIE, com diferença entre as titulações lenta e rápida de -0,6 (± 1,2) cmH2O. A PaCO2 foi significantemente maior (p=0,01) na titulação lenta quando comparado com a rápida. No seguimento por 1 hora, a estratégia PEEP TIT-2 determinou menores valores de complacência (p < 0,001), menor PaO2 (p=0,001) e maior porcentagem de shunt (p < 0,01) quando comparado com as estratégias PEEP TIT e PEEP TIT+2. Conclusões: a titulação rápida teve boa concordância com titulação lenta e determinou menos hipercapnia; 2) a PEEP ótima escolhida por titulação rápida utilizando TIE (colapso recrutável inferior a 1%) conseguiu manter boa estabilidade pulmonar e oxigenação durante 1 hora de monitorização; 3) não houve diferença entre o colapso recrutável estimado pelo TIE e pela TC dinâmica / Introduction: The protective strategy of mechanical ventilation for Acute Respiratory Distress Syndrome (ARDS), which combines low tidal volume with higher PEEP, is an effective intervention to reduce the morbimortality of this syndrome. There is a consensus about setting tidal volume, but the method of choosing PEEP is still controversial. Decremental PEEP titration, following an alveolar recruitment maneuver, is a well-accepted method with physiological basis. The choice of PEEP is based on respiratory system complacency or imaging methods that assess lung collapse. This titration is usually done slowly (4-10 minutes in each step) which makes its execution difficult in clinical practice and increases the risk for the patient. In addition, the criteria for choosing the value of PEEP that maintains pulmonary stability over time are still uncertain. Objectives: 1) to compare, in a severe ARDS model in pigs, using Electrical Impedance Tomography (EIT) and Computed Tomography (CT), the decremental PEEP titration in a conventional maneuver (slow, 32 minutes) and fast (6 minutes); and 2) to evaluate the pulmonary stability and hemodynamics (respiratory system compliance, shunt, PaO2 and cardiac output) during 1 hour of mechanical ventilation with 3 PEEP values defined by EIT: PEEP with less than 1% lung tissue collapse (PEEP TIT); less than 1% collapse of lung tissue + 2cm H2O (PEEP TIT + 2) and less than 1% collapse of lung tissue - 2cmH2O (PEEP TIT - 2). Methods: Twenty-five animals were studied, 6 of which also performed CT and 11 animals were monitored over time. Results: No difference was observed in the percentage of collapse found by the two imaging methods (CT and EIT), both in fast (p = 0.89) and slow (p = 0.86) titrations. There was a good concordance between the fast and slow titrations performed by EIT, with a difference between the slow and fast titrations of -0.6 (± 1.2) cmH2O. PaCO2 was significantly higher (p = 0.01) in slow titration than in fast titration. At the 1-hour follow-up, the PEEP TIT-2 strategy determined lower values of compliance (p < 0.001), lower PaO2 (p = 0.001) and higher shunt (p < 0,01) when compared with PEEP TIT and PEEP TIT +2 strategies. Conclusions: 1) fast titration had good agreement with slow titration and causes less hypercapnia; 2) optimum PEEP chose by fast titration using EIT (recruitable-collapse lower than 1%) was able to maintain good lung function and oxygenation during 1 hour of monitoring; 3) there was no difference between the recruitable collapse estimated by EIT and by dynamic CT
96

Quantificação à beira do leito do potencial de recrutamento alveolar através da tomografia de impedância elétrica em modelo experimental síndrome do desconforto respiratório agudo / Bedside quantification of alveolar recruitment potential using electrical impedance tomography in an experimental model of acute respiratory distress syndrome

Roberta Ribeiro de Santis Santiago 19 January 2016 (has links)
Introdução: A síndrome do desconforto respiratório agudo (SDRA) tem como parte do seu tratamento uma ventilação mecânica adequada. A manobra de recrutamento alveolar (MRA) faz parte de um grupo de estratégias empregadas nos quadros moderados e graves. A MRA consiste na aplicação de um aumento de pressão transitório e controlado nas vias aéreas no intuito de abrir alvéolos previamente colapsados. A Tomografia de Impedância Elétrica (TIE) é capaz de avaliar o potencial de recrutamento alveolar (PRA) a beira leito. Objetivos:1) Comparar o PRA calculado pela TIE (através do ganho de complacência regional) com a TC. 2) Avaliar o \"deslocamento vertical de volume\" como índice de recrutamento alveolar.3) Estimar precocemente o PRA, através das manobras de recrutamento de rastreio propostas, utilizando a TIE. Método: Avaliamos o PRA em um modelo experimental de SDRA. Utilizamos 15 suínos da raça Landrace. Os animais foram sedados e intubados, em seguida, submetidos ao modelo experimental de SDRA desenvolvido na Faculdade de Medicina da Universidade de São Paulo (LIM-09). Ao término da lesão, um grupo de 7 animais recebeu uma sequência randomizada de manobras de recrutamento de rastreio propostas (Pressões inspiratórias de 30, 35 e 40 cmH2O) seguidas da manobra de recrutamento máxima (Pressão inspiratória de 60 cmH2O). Os animais foram monitorados com TIE e Tomografia computadorizada por raio X (TC) durante todas as manobras de recrutamento. Outro grupo de 8 animais ,submetidos a mesma lesão e com medidas de TC e TIE, foi retirado do banco de dados do LIM-09 e também analisados. Utilizamos o programa IBM® SPSS® Statistics 9.0 e 20.0.Resultados:1) PRA calculado pela TIE atráves do ganho de complacência regional corrigido para hiperdistensão, comparado com TC, apresentou um R2=0,76. 2) PRA calculado pelo ganho de complacência regional corrigido para hiperdistensão combinado com o deslocamento vertical apresentou R2 = 0,91 comparado a TC .3) As manobras de rastreio não conseguiram predizer quantitativamente o PRA mas auxiliariam na correção da hiperdistensão. Conclusões: A TIE é capaz de avaliar o recrutamento alveolar a beira leito. O deslocamento vertical combinado com o ganho de complacência regional corrigida para hiperdistensão representam de forma semelhante a TC o comportamento pulmonar durante uma MRA. A aplicação de uma manobra de recrutamento de rastreio pode ser útil para uma manobra de recrutamento máxima mais segura / Introduction: The acute respiratory distress syndrome (ARDS) treatment demands a proper mechanical ventilation strategy. The alveolar recruitment maneuver (ARM) is an intervention applied in moderate and severe cases of ARDS. ARM is a transitory and controlled increase in mechanical ventilator pressure delivered to the lungs aiming to open previously collapsed alveoli. The electrical impedance tomography (EIT) is a valuable tool at bedside; it is able to monitor and to help during an ARM performance through the estimation of the alveolar recruitment potential (ARP). Objectives: 1) To compare the ARP with the EIT as a regional compliance improvement quantification adjusted for lung hyperdistention with CT. 2) To evaluate the \"volume vertical displacement\" at the same pressure as alveolar recruitment index using EIT and CT. 3) To estimate earlier the ARP using the EIT through a screening recruitment maneuver. Methods: We evaluated the ARP in an experimental model of ARDS. We studied 15 Landrace race pigs. Subjects were sedated, intubated and submitted to the ARDS experimental model developed at Medical investigation laboratory n ° 09, University of São Paulo. In the end of the lung injury, a group of 7 pigs received a randomized sequence of screening recruitment maneuvers (inspiratory pressures of 30, 35 and 40 cmH2O) followed by a maximum recruitment maneuver (inspiratory pressure of 60 cmH2O).EIT and x-ray computed tomography (CT) monitored the steps of each recruitment maneuver. Another group of 8 pigs, submitted to the same lesion and with measures of EIT and CT, were extracted from our data bank. Analysis was performed at IBM® SPSS® Statistics 20.0. Results: 1) ARP calculated by EIT (regional compliance improvement quantification) reached a R2=0,76 when compared to CT. 2) The combination of regional compliance improvement and volume vertical displacement obtained R2 = 0,91 when compared to CT 3) The screening recruitment maneuvers were not able to predict quantitatively the ARP, but they helped in the lung hyperdistension adjustment. Conclusions: EIT is able to evaluate the ARP at bedside. The combination of regional compliance improvement and volume vertical displacement give information similar to CT about the lung behavior during a ARM. The application of a recruitment screening maneuver might be useful for more safe ARM
97

Efeitos interativos da pressão expiratória final positiva (PEEP) e da fração inspirada de oxigênio (FIO2) no colapso pulmonar durante anestesia geral em modelo experimental suíno / Interactive effects of positive-end expiratory pressure (PEEP) and fraction of inspired oxygen (FIO2) on pulmonary collapse during general anesthesia in experimental swine model

José Renato de Melo 25 October 2017 (has links)
INTRODUÇÃO: O desenvolvimento de colapso pulmonar (atelectasia) durante anestesia geral com ventilação mecânica é frequente, podendo determinar hipoxemia e contribuir para desenvolvimento de outras complicações pós-operatórias, como infecção e síndrome do desconforto respiratório agudo (SDRA). O uso de fração inspirada de oxigênio (FIO2) baixa e de pressão expiratória final positiva (PEEP) podem reduzir a quantidade de pulmão atelectasiado. Existem poucos dados experimentais sobre a cinética do desenvolvimento da atelectasia no intraoperatório em diferentes ajustes de FIO2 e PEEP no decorrer do tempo. A Tomografia de impedância elétrica (TIE) do tórax permite uma análise contínua e não invasiva da função pulmonar, bem como da quantificação do colapso e pode ser usada no intraoperatório. OBJETIVOS: a) avaliar, em animais com pulmões sadios durante anestesia geral, o efeito do uso de uma PEEP individualizada escolhida através da TIE (\"PEEP titulada\"), na formação de colapso; b) analisar a magnitude e a cinética de desenvolvimento do colapso pulmonar no decorrer do período de uma hora em dois valores de FIO2 (0,4 e 1) e dois valores de PEEP (3 cmH2O e valor da PEEP titulada) através da TIE e Tomografia computadorizada (TC); c) analisar mecânica, ventilação regional e aeração pela TIE e troca gasosa nos diferentes períodos do estudo. MÉTODOS: Nove animais (suínos) com pulmão normal foram submetidos à manobra de titulação da PEEP para escolha da PEEP que determina colapso pulmonar mínimo (colapso menor que 3% determinado pela TIE, denominada \"PEEP titulada\") e posteriormente ventilados com volume corrente de 6ml/Kg em quatro ajustes, em sequência randomizada, por um período de 1 hora: FIO2 0,4 e PEEP 3, FIO2 0,4 e PEEP titulada, FIO2 1 e PEEP 3 e FIO2 1 e PEEP titulada. O colapso, ventilação regional e aeração foram medidos continuamente, através da TIE assim como dados da mecânica. Mensuramos troca gasosa e aeração pulmonar pela TC em 3 momentos em cada período do estudo (baseline, 5 e 50 minutos). RESULTADOS: A PEEP titulada foi de 11,6 ±1,4 cm H2O. Houve colapso progressivo no decorrer do tempo nos 4 grupos estudados tendo sido maior na PEEP 3 que na PEEP titulada. A medida do colapso pela TIE não foi influenciada pela FIO2 utilizada, ao contrário da mensuração pela TC na qual o colapso foi maior na FIO2 de 1. Houve queda da complacência pulmonar e aumento da pressão de distensão no decorrer do tempo, maiores na PEEP 3, sem influência da FIO2. Na região dorsal, a TIE evidenciou redução da ventilação (delta Z) na PEEP 3, sem influência da FIO2, e, também, redução da aeração (mínimo Z) que foi maior na PEEP 3 e na FIO2 de 1. Houve queda da relação PaO2/FIO2 e aumento do shunt e mistura venosa na PEEP 3. Não houve alterações hemodinâmicas clinicamente relevantes durante o estudo. CONCLUSÕES: Houve colapso progressivo no decorrer do tempo, sendo maior na PEEP 3 que na PEEP titulada. O colapso aferido pela TC foi maior na FIO2 de 1 do que na 0,4 para uma mesma PEEP, diferente da TIE cuja estimativa de colapso não foi diferente. Paralelamente houve queda da complacência pulmonar, aumento da pressão de distensão e redução da ventilação dorsal, maiores na PEEP 3 e sem influência da FIO2. A queda da aeração estimada pela TIE foi maior na PEEP 3, sendo que nas duas PEEP a aeração foi menor na FIO2 de 1 / INTRODUCTION: The development of pulmonary collapse (atelectasis) during general anesthesia with mechanical ventilation is frequent, which can determine hypoxemia and contribute to the development of other postoperative complications, such as infection and acute respiratory distress syndrome (ARDS). The use of low fraction of inspired oxygen (FIO2) and positive end expiratory pressure (PEEP) may reduce the amount of collapsed lung. There are few experimental data on the kinetics of intraoperative atelectasis development in different FIO2 and PEEP adjustments over time. Electrical impedance tomography (EIT) of the thorax allows a continuous and noninvasive analysis of pulmonary function as well as the quantification of pulmonary atelectasis and can be used intraoperatively. OBJECTIVES: a) to evaluate, in animals with healthy lungs during general anesthesia, the effect of the use of an individualized PEEP chosen through EIT (titrated PEEP), in the formation of collapse; b) to analyze the magnitude and development kinetics of pulmonary collapse during the one-hour period in two values of FIO2 (0.4 and 1) and two PEEP values (3 cmH2O and titrated PEEP value) through EIT and computed tomography (CT); c) to analyze mechanics, regional ventilation and aeration by EIT and gas exchange in the different periods of the study. METHODS: Nine animals (swine) with normal lung were submitted to a PEEP titration maneuver to select PEEP that determines minimal pulmonary collapse (collapse of less than 3% determined by EIT, called \"titrated PEEP\") and then ventilated with a tidal volume of 6ml / kg in four adjustments, in a randomized sequence, for a period of 1 hour: FIO2 0.4 and PEEP 3, FIO2 0.4 and titrated PEEP, FIO2 1 and PEEP 3 and FIO2 1 and titrated PEEP. The collapse, regional ventilation and aeration were measured continuously through EIT as well as mechanics data. We also measured gas exchange and aeration by CT at 3 times in each study period (baseline, 5 e 50 minutes). RESULTS: The titrated PEEP was 11.6 ±1.4 cm H2O. There was a progressive collapse over time in the 4 groups studied, having been higher in PEEP 3 than in titrated PEEP. The measurement of EIT collapse was not influenced by the FIO2 used, as opposed to the CT measurement in which the collapse was greater in the FIO2 1. There was a decrease in pulmonary compliance and an increase in drive pressure over time, higher in PEEP 3, without influence of FIO2. In the dorsal region, EIT showed a decrease in ventilation, as measured by delta Z, in PEEP 3, with no influence of FIO2; there was also reduction of aeration, measured by the minimum Z, higher in PEEP 3 and FIO2 of 1. There was a decrease in the PaO2 / FIO2 ratio and increased in shunt and venous admixture in PEEP 3. There was no clinically relevant change in hemodynamics during the study. CONCLUSIONS: There was a greater collapse in PEEP 3 than in titrated PEEP over time. Collapse measured by CT was higher in FIO2 of 1 than 0.4 for the same PEEP, different from EIT estimates of collapse which was not different. Beside the collapse, there were decrease in compliance, increase in driving pressure and reduction of dorsal ventilation, higher in PEEP 3 without FIO2 influence. The decrease of aeration estimated by EIT was higher in PEEP 3 and for both PEEP values aeration was lower with FIO2 of 1
98

Inovação biomédica e o animal não humano em pesquisa: controvérsias científicas e reflexões éticas para contribuição na implementação de políticas públicas de técnicas substitutivas ao uso de animais em pesquisa, ensino e indústria / Biomedical innovation and the non-human animal research : scientific controversies and ethical reflections contribution to the implementation of public policies substitutive techniques to animal use in research ,teaching and industry

Tatiana Tavares da Silva 26 May 2014 (has links)
A experimentação animal é uma prática extremamente incorporada à ciência biomédica moderna, com raízes desde a Antiguidade, mas que foi cada vez mais se desenvolvendo, adquirindo características bem definidas. O animal não humano, no contexto da experimentação, é um ser vulnerado, enclausurado dentro de uma estrutura muito bem definida, que mantém um discurso focado na excelência do modelo do animal na pesquisa e testes, com o objetivo de garantir a manutenção dessas práticas. No entanto, ao analisarmos os dados científicos obtidos com a experimentação animal, que visa primariamente um possível benefício humano, assim como as argumentações éticas relativas ao respeito à vida e ao sofrimento do animal envoltas nesta situação, a argumentação ética prepondera sobre uma base científica cuja eficácia é também extremamente questionável. Partindo de uma análise crítica da aplicação do modelo animal como padrão da pesquisa científica e da concepção ética do reconhecimento da vulnerabilidade do animal não humano na experimentação, propomos que esta reflexão colabore com políticas públicas que incentivem e implementem as técnicas substitutivas ao uso de animais não humanos em pesquisa, testes da indústria e ensino na área biomédica no Brasil. / Animal experimentation is an extremely convenient inserted in modern biomedical science, with roots from antiquity, but it was increasingly developing, acquiring well-defined characteristics. The non-human animal in the context of trials is a hacked being, enclosed within a well defined structure that holds a speech focused on excellence in animal model in research and testing, with the goal of maintaining these practices. However, when analyzing the scientific data obtained from animal experiments, which primarily targets a possible human benefit, as well as the ethical arguments concerning respect for life and the suffering of animals wrapped in this situation, the ethical argument outweighs scientific basis whose effectiveness is also extremely questionable. Based on a critical analysis of the application of animal model as the standard of scientific research and the ethical conception of recognition of the vulnerability of non-human animal experimentation, we propose that this reflection collaborate with public policies that encourage and implement the substitute for use of non-human animals in research, testing and education industry in Brazil biomedical techniques.
99

Inovação biomédica e o animal não humano em pesquisa: controvérsias científicas e reflexões éticas para contribuição na implementação de políticas públicas de técnicas substitutivas ao uso de animais em pesquisa, ensino e indústria / Biomedical innovation and the non-human animal research : scientific controversies and ethical reflections contribution to the implementation of public policies substitutive techniques to animal use in research ,teaching and industry

Tatiana Tavares da Silva 26 May 2014 (has links)
A experimentação animal é uma prática extremamente incorporada à ciência biomédica moderna, com raízes desde a Antiguidade, mas que foi cada vez mais se desenvolvendo, adquirindo características bem definidas. O animal não humano, no contexto da experimentação, é um ser vulnerado, enclausurado dentro de uma estrutura muito bem definida, que mantém um discurso focado na excelência do modelo do animal na pesquisa e testes, com o objetivo de garantir a manutenção dessas práticas. No entanto, ao analisarmos os dados científicos obtidos com a experimentação animal, que visa primariamente um possível benefício humano, assim como as argumentações éticas relativas ao respeito à vida e ao sofrimento do animal envoltas nesta situação, a argumentação ética prepondera sobre uma base científica cuja eficácia é também extremamente questionável. Partindo de uma análise crítica da aplicação do modelo animal como padrão da pesquisa científica e da concepção ética do reconhecimento da vulnerabilidade do animal não humano na experimentação, propomos que esta reflexão colabore com políticas públicas que incentivem e implementem as técnicas substitutivas ao uso de animais não humanos em pesquisa, testes da indústria e ensino na área biomédica no Brasil. / Animal experimentation is an extremely convenient inserted in modern biomedical science, with roots from antiquity, but it was increasingly developing, acquiring well-defined characteristics. The non-human animal in the context of trials is a hacked being, enclosed within a well defined structure that holds a speech focused on excellence in animal model in research and testing, with the goal of maintaining these practices. However, when analyzing the scientific data obtained from animal experiments, which primarily targets a possible human benefit, as well as the ethical arguments concerning respect for life and the suffering of animals wrapped in this situation, the ethical argument outweighs scientific basis whose effectiveness is also extremely questionable. Based on a critical analysis of the application of animal model as the standard of scientific research and the ethical conception of recognition of the vulnerability of non-human animal experimentation, we propose that this reflection collaborate with public policies that encourage and implement the substitute for use of non-human animals in research, testing and education industry in Brazil biomedical techniques.
100

Efeitos pulmonares da hemodiluição normovolêmica aguda com hidroxietilamido ou ringer lactato em porcos / Pulmonary effects of Acute Normovolemic Hemodilution (ANH) with hydroxyethyl starch and lactated Ringer\'s in pigs

Clarita Bandeira Margarido 20 September 2005 (has links)
Introdução: A hemodiluição normovolêmica aguda (HNA) é estratégia utilizada para diminuir a necessidade de transfusão em procedimentos cirúrgicos. O hematócrito alvo, a solução empregada e os riscos da HNA são controversos e, embora as ações sobre os sistemas nervoso e cardiocirculatório tenham sido extensamente pesquisados, há poucos estudos sobre implicações pulmonares da HNA. O objetivo deste estudo é avaliar os efeitos pulmonares da HNA comparando amido hidroxietílico e Ringer lactato. Métodos: Vinte e cinco porcos foram monitorizados e cateterizados. Utlizou-se anestesia intravenosa contínua com propofol, cetamina, fentanil e pancurônio. Após estabilização da anestesia, os animais foram randomizados: Grupo Controle (n=8), Grupo HES (amido hidroxietílico, n=7) e Grupo RL (Ringer lactato, n=10). Os animais dos grupos II e III foram submetidos a HNA até hematócrito pré-estabelecido de 15%. A retirada do sangue foi acompanhada da expansão plasmática com amido hidroxietílico ou Ringer lactato na proporção de 1:1 ou 3:1 respectivamente. Medidas de mecânica respiratória e oxigenação sangüínea foram realizadas antes da retirada de sangue (T0), ao término da hemodiluição (T1) e após uma e duas horas (T2 e T3). Ao final foram realizadas biópsias pulmonares. Os dados foram submetidos à análise de variância para medidas repetidas (ANOVA) seguidas pelo teste de Tukey. Resultados: Em relação aos parâmetros do grupo controle, não houve diferença significante durante todo o procedimento. O grupo Ringer lactato demonstrou diminuição da complacência estática e aumento da diferença alvéolo-arterial de O2 (DAa-O2) em relação ao controle (*P<0,05). A análise histopatológica evidenciou atelectasias e alargamento da membrana basal na barreira alvéolo-capilar no grupo Ringer lactato. O grupo amido hidroxietílico apresentou comportamento semelhante ao grupo controle. Conclusões: O estudo sugere que na HNA acentuada, o amido hidroxietílico é superior na preservação estrutural do pulmão, evidenciado pormanter a complacência pulmonar e a oxigenação, quando comparada à realizada com solução de Ringer lactato / Introduction: Acute normovolemic hemodilution (ANH) is a common procedure to decrease the needs of blood transfusion during a variety of surgical procedures. There are controversies regarding ANH such as the target hematocrit, the solution to be used and its risks. Although its effects in heart and brain have been extensively studied; investigations concerning its pulmonary effects are lacking. The aim of this experiment was to compare the pulmonary effects of ANH with hydroxyethyl starch and lactated Ringer\'s. Methods: Twenty five pigs were instrumented for standard hemodynamic monitoring. Intravenous anesthesia consisted continuous infusion of propofol, ketamine, fentanyl and pancuronium. After anesthesia stabilization animals were randomized: Control group (n=8), HES group (hydroxyethyl starch, n=7) and LR group (lactated Ringer\'s, n=10). Animals of Control Group were anesthetized and observed. Group Animals of group HES and LR were submitted to ANH to reach a pre-established hematocrit around 15%. Blood withdrawal was accomplished simultaneously with plasma expansion performed with hydroxyethyl starch (1:1) or with lactated Ringer\'s (3:1). Pulmonary mechanics and oxygen transport and were measured before blood withdrawal (T0), at the end of hemodilution (T1), and one and two hours after the end of the hemodilution (T2, T3). Lungs biopsies were performed at the end. Data were submitted to analysis of Variance for repeated measures followed by the Tukey test. Results: In regard to all parameters of Control group, there were no significant differences during the whole procedure. The LR group demonstrated a decrease in compliance and an increased in (a-A)DO2 (*P<0,05). Hystopathological lung analysis revealed moderate to serious collapses as well as basement membrane enlargement in group LR. The HES data were similar to that found in control group. Conclusion: These results suggest that in severe ANH, HES preserves pulmonary structure and seems to less interfere with pulmonary mechanics and oxygenation indexes when compared to lactated Ringer\'s

Page generated in 0.0938 seconds