• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 159
  • 10
  • 1
  • Tagged with
  • 171
  • 40
  • 34
  • 32
  • 27
  • 26
  • 24
  • 22
  • 21
  • 20
  • 18
  • 18
  • 17
  • 16
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Modelo de apoio à decisão para seleção de tecnologias de revestimento de fachadas / Decision aid model for facades cladding technologies selection

Gondim, Ivo Almino January 2007 (has links)
O interesse em reduzir manifestações patológicas, o possível impacto sobre a satisfação dos clientes e a busca por redução de custos são alguns dos fatores que, durante as fases de projeto arquitetônico, podem tornar complexa a decisão referente à seleção de uma tecnologia de revestimento de fachada. Diante disso, o presente trabalho tem como objetivo propor um modelo de apoio à decisão para seleção de tecnologias de revestimento de fachadas. O desenvolvimento do trabalho envolveu quatro fases de pesquisa. Na primeira, foi realizado um estudo sobre como são tomadas as decisões, com identificação dos atores envolvidos, caracterização das diferenças entre as alternativas potenciais e definição dos contornos da problemática de decisão. Na segunda fase, estruturou-se um modelo de decisão multicritério adequado para o contexto de decisão de interesse. O modelo desenvolvido leva em conta aspectos considerados importantes por profissionais com ampla experiência e incorpora características positivas identificadas em outros modelos encontrados na prospecção da bibliografia existente na área. Em seguida, na terceira fase, foram efetuados testes de aplicação do modelo, com seis decisores, tomando como referência um cenário de decisão fictício, estabelecido levando em conta as características da cidade de Fortaleza. A captura do sistema de valores dos decisores foi efetuada através de formulários. Os resultados oriundos dos formulários, com o auxílio de software e planilhas eletrônicas, serviram de base para que o modelo apresentasse suas recomendações. Durante as aplicações, os resultados parciais das capturas de conhecimento eram discutidos com os participantes do teste e analisados pelo pesquisador, com o objetivo de verificar se o procedimento deveria sofrer refinamentos ou ajustes. Por fim, na quarta fase, foi realizada uma validação qualitativa do modelo, através de entrevistas e formulários nos quais se discutia se a previsão do modelo seria útil e se coadunava com as expectativas dos decisores. Os resultados obtidos indicam que existe viabilidade para aplicação do modelo proposto, pois o mesmo foi considerado útil e válido pelos decisores dentro do seu contexto de aplicação. Acredita-se que, com o desenvolvimento e aperfeiçoamento da ferramenta proposta, a mesma venha a contribuir de forma significativa para apoiar escolhas de decisores na construção civil, em especial, em situações em que existem dúvidas sobre a tecnologia mais apropriada. Mais ainda, ao estruturar o processo de decisão, a mesma permite que se discutam os parâmetros e valores que influenciam cada decisão, permitindo uma melhor reflexão e consenso entre os intervenientes. / Interests in decreasing pathological manifestations, improve customers’ satisfaction and promote cost reductions are important considerations that, during the design building phase, may increase the complexity of the decision regarding facades cladding technology. The main purpose of the present work is to suggest a decision aid model for technological decisions, in the choice of facades cladding technologies. The research development involved four phases. In the first one, it was studied about how decisions are taken, with stakeholders’ identification, potential action characterization, and problematic definition. In the second phase, it was structured a model in accordance with context interests. The decision aid model considers aspects judged as important by experienced professionals and considers positive characteristics identified by models found in the literature of the area. In the third phase, simulation tests were realized with six decision makers, considering a fictitious project in Fortaleza city. Using formularies, individual values were captured from decision makers. The results collected with the aid of software and electronic sheets served as the basis for model recommendations. During the application of the model, partial results were discussed with decisionmakers and analyzed by the researcher so that they could be refined or adjusted. Finally, in the fourth phase, a qualitative validation was carried through interviews and formularies. This phase verified if the decision aid model was considered useful and valid by decision-makers. It was shown that the proposed tool can significantly contribute to help decision makers in the selection of facades cladding technologies, especially in complex situations. More yet, it can help to structure the decision process, becoming an important the tool for discussing the parameters and values influencing decisions, and helping stakeholders to reach a consensed solution.
92

Análise da durabilidade dos componentes das fachadas de edifícios, sob a ótica do projeto arquitetônico

Consoli, Osmar João January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-graduação em Engenharia Civil / Made available in DSpace on 2012-10-22T08:19:50Z (GMT). No. of bitstreams: 1 239904.pdf: 4530685 bytes, checksum: acc1506060575f4f40987777dfb0d686 (MD5) / O envelhecimento dos edifícios e suas fachadas é um processo natural e acredita-se que as que falhas ou omissões a partir dos projetos arquitetônicos sejam responsáveis por ocorrências mais acentuadas de patologias em fachadas, o que requer procedimentos de recuperação e manutenção mais onerosos para restabelecer o desempenho perdido, uma vez que as patologias podem comprometer a segurança, a habitabilidade. O objetivo deste estudo é numa seleção de edifícios de até cinco pavimentos construídos com o sistema construtivo tradicional cidade de Pato Branco, Paraná diagnosticar a grande quantidade de patologias encontradas nas fachadas de que tiveram origens na etapa de projetos. A metodologia utilizada se estrutura nos princípios da avaliação pós-ocupação com investigação sistêmica de dados de modo a fornecer subsídios para diagnosticar as causas das patologias, neste sentido foram analisados em cada edifício: seus projetos arquitetônicos na busca de imperfeições nas soluções gráficas ou de especificações técnicas, as manutenções ocorridas, investigação detalhada da patologias de cada fachada e ampla pesquisa bibliográfica com ênfase aos agentes de degradação, nas soluções de projetos, nos requisitos de desempenho quais forneceram os subsídios para compreensão dos fenômenos patológicos que fundamentaram os diagnósticos e subsidiaram as recomendações de projeto arquitetônico para aumentar a durabilidade destas fachadas. Os dados das fachadas foram mapeados por roteiro preestabelecido com especial atenção àquelas ocorridas nas interfaces dos elementos construtivos, catalogados por tipo de ocorrência, por freqüências de ocorrência, pela gravidade da patologia, assim, a análise destas variáveis caracterizou que grandes partes das patologias surgiram em decorrência de erros ou omissões na fase dos projetos arquitetônicos. Os resultados demonstram que há patologias de diversas origens, naqueles de natureza de projetos são oriundas de omissões de detalhes construtivos, de especificações, de métodos executivos incorretos, de erros de projetos e de falta de especificação rotineira de manutenção. Para muitos casos patológicos as recomendações descritas neste trabalho para projetos podem ser suficientes para sanar tais problemas, uma vez deve haver um conjunto mínimo de elementos gráficos que compreendam a pormenorização em detalhes arquitetônicos que compatibilize os aspectos construtivos e as propriedades dos materiais, os agentes de degradação atuantes e os procedimentos rotineiros de manutenção que, por conseqüência, permitem o prolongamento da vida útil destas fachadas. Finalmente, o estudo mostrou que projetos, ou memoriais descritivos com especificações corretas, induzem a correta execução da obra que minimizam as intervenções de manutenção e de recuperação, obtendo maior durabilidade das fachadas e maximizando a satisfação do usuário.
93

Avaliação da eficiência de autolimpeza em argamassas e pastas contendo TiO2 expostas ao microclima urbano / Self-cleaning evaluation of TiO2-containing mortars and pastes exposed to an urban atmosphere

Treviso, João Pedro Marins January 2016 (has links)
Ao longo do tempo, os revestimentos de fachada permanecem expostos a diversos agentes de degradação, sejam eles associados aos próprios materiais empregados ou a fatores externos. Tal exposição implica em manchas formadas a partir da deposição de partículas poluentes na superfície dos revestimentos, elevando seus custos para limpeza e manutenção. Uma vez que permanecem expostas à radiação solar, as fachadas se mostram atraentes ao uso de materiais fotocatalíticos, os quais catalizam a mineralização de agentes poluentes, transformando-os em produtos inócuos. A adição de dióxido de titânio (TiO2) a argamassas e concretos de cimento branco desenvolve superfícies autolimpantes, reduzindo a formação de manchas e mantendo sua coloração original ao longo do tempo. No entanto, a eficiência e a economia no uso de materiais fotocatalíticos em aplicações reais é fortemente afetada pela disponibilidade da radiação ultravioleta adequada para ativá-los. Portanto, o presente trabalho busca avaliar a capacidade autolimpante de argamassas e coberturas fotocatalíticas de TiO2 expostas a diferentes configurações de posicionamento no microclima urbano da cidade de Porto Alegre. Para isto, foram confeccionadas amostras de argamassa e coberturas de pasta ou argamassa contendo diferentes teores de TiO2, as quais foram manchadas com Rodamina B e lodo de cinzas da queima de eucalipto e, a seguir, expostas sob diferentes condições de posicionamento, voltadas para as orientações norte, sul, leste e oeste, à 0º, 45º e 90º. Ao longo do período de exposição, foram realizadas leituras cromáticas (sistema CIELab) na superfície das amostras, tendo em vista a descoloração dos manchamentos aplicados. Para aquelas manchadas com Rodamina B, a degradação do corante se mostrou mais eficiente nas argamassas com maiores teores de TiO2 e nas configurações de posicionamento que recebem maior incidência de radiação solar. As coberturas de pasta apresentaram valores mais elevados de variação de cor (ΔE) e refletância (L*), na comparação à aplicação do TiO2 como cobertura de argamassa ou incorporado à mistura − métodos os quais se mostraram resultados equivalentes. / Building façades are commonly exposed to polluting agents generated by vehicles and industries exhausts, which cause stains on their surfaces and increase efforts and costs both for cleaning and maintenance. Facades are attractive to photocatalytic materials usage, which transform pollutants to innocuous products. The addition of titanium dioxide (TiO2) to white cement mortars and concretes develops self-cleaning surfaces which are capable to reduce stains and maintain their original color along the time. However, efficiency and economy in the use of photocatalytic materials in real applications are strongly affected by the availability of suitable ultraviolet radiation to activate them. This thesis aims to evaluate the self-cleaning ability of TiO2-containing mortars and coatings (paste or mortar) exposed to controlled positioning settings in the urban environment of Porto Alegre, Brazil. Mortars and coatings were prepared containing different additions of TiO2 and then were soiled by Rhodamine B (RhB) or burning ashes of eucalyptus sludge. Samples were exposed under outdoor conditions facing north, south, east and west orientations, 0º, 45º or 90º slopes. During the exposure test, discoloration effect on samples' surface was monitored by colorimetric measurements (CIELab color space) using a portable spectrophotometer. A final analysis was performed at the end of the measurements, including statistical tests. Self-cleaning ability was better seen both for higher additions of TiO2 and settings which receive higher intensities of solar radiation. Cement paste coatings showed higher values both of color change and reflectance when compared to mortar coatings or TiO2 added to the mixture − which performed equivalent results.
94

Análise crítica de experiências e discussão de estratégias para implantação de leis de inspeção de elementos de fachadas / Critical analysis on experiences and discussion of strategies for the implementation of façade element inspection laws

Oliveira, Cristiane Sardin Padilla de January 2013 (has links)
O presente trabalho faz uma avaliação do histórico de desenvolvimento e aplicação de leis de inspeções prediais em geral no Brasil, com foco particular nas leis especificas de inspeção de elementos de fachada. O mesmo busca discutir os papéis dessas leis como instrumentos de gestão de riscos na construção civil, destacando os avanços, limitações e tendências do processo de implantação desse tipo de legislação. A lógica e o conhecimento teórico acumulado na área indicam que a adoção de um sistema de inspeção adequado pode contribuir para a detecção precoce de problemas, que podem então ser corrigidos através de ações de manutenção preventiva, com menor custo e risco para os usuários. Essa é uma demanda fundamental em muitas cidades brasileiras, que apresentam um conjunto de edificações em idade avançada e com problemas de conservação. Sinistros repetidos, culminando na tragédia ocorrida no Rio de Janeiro em 2012, fizeram com que a edição de leis de inspeção entrasse na pauta política de várias administrações e do Congresso Nacional. Todavia, a análise de experiências práticas evidencia que existem dificuldades e obstáculos, culturais, técnicos e econômicos, que necessitam ser discutidos e superados para que uma estratégia de gestão de risco através de leis de inspeção possa ser adotada de forma eficaz. O trabalho busca colaborar com essa discussão, revisando criticamente a experiência de Porto Alegre, um dos primeiros municípios a implantar uma lei de inspeção específica de elementos de fachada, a Lei Municipal nº 6.323/88, regulamentada pelo Decreto 9425. Esses regramentos determinaram que os responsáveis pelas edificações apresentassem à Secretaria Municipal de Obras e Viação (SMOV), a cada 03 anos, um laudo de estabilidade estrutural das marquises localizadas sobre logradouros públicos. Essa lei, popularizada como “Lei das Marquises”, foi criada em resposta a 2 sinistros traumáticos envolvendo a queda de seções de marquises no centro da cidade, ocorridos no final dos anos 80, e teve um impacto importante no estado de conservação do estoque de marquises da cidade. Ao mesmo tempo, representou um marco significativo no histórico de implantação de leis de inspeção no Brasil, tendo influenciado vários outros municípios a adotar legislações semelhantes. Após 30 anos, considera-se importante avaliar seus efeitos e analisar as evoluções e dificuldades enfrentadas em sua aplicação, de forma a que seja possível orientar outras experiências. Essa é a motivação fundamental da pesquisa. Para complementar e enriquecer as análises, o trabalho buscou gerar um indicativo da eficiência e qualidade dos Laudos de Marquise que estão sendo entregues. Com esse intuito, a autora, auxiliada por outros pesquisadores do Grupo LEME/UFRGS, efetuou uma inspeção paralela de 135 estruturas, gerando dados usados para comparação com os constantes em laudos arquivados na Secretaria Municipal de Obras e Viação (SMOV). Em paralelo, se buscou uma forma de avaliar qual a percepção da população acerca dos conceitos associados à implantação de leis de inspeção e estratégias de manutenção preventiva, e estimar qual a aceitação dos custos associados a essas estratégias. Para tanto foi realizado um levantamento de dados, através de entrevistas e questionários, junto a usuários de 24 edificações da região metropolitana de Porto Alegre. Esse esforço evidenciou que existe um bom conhecimento dos riscos e uma aceitação da necessidade de inspeções, mas que o custo ainda é uma barreira. Visando aproveitar e consolidar todo o conhecimento adquirido nessas diversas análises, o trabalho finaliza apresentando uma proposta de diretrizes consideradas úteis para orientar a implantação de leis de inspeção de elementos de fachada. / This study evaluated the history of the development and application of building inspection laws in Brazil in general, with special focus on specific laws for the inspection of façade elements. The role of these laws as risk management tools in civil construction is discussed, stressing developments, limitations and trends of their implementation process. Logics and the theoretical knowledge accumulated on this subject suggest that the adoption of a proper system may allow the early detection of problems, which can then be corrected by preventive maintenance actions, and therefore are less costly and pose fewer risks to the users. This is a critical demand in many Brazilian cities that have many old buildings with conservation problems. Repeated accidents, which culminated in the tragedy in Rio de Janeiro in 2012, inserted the issuing of inspection laws in the political agenda of many local administrations and of the National Congress. However, the analysis of practical experiences shows that there are cultural, technical, and economic obstacles that need to be discussed and overcome to allow the adoption of an efficient risk management strategy based on inspection laws. This study aims at contributing for this discussion making a critical review of the experience of Porto Alegre, which was one of the first cities to implement a specific law for the inspection of façade elements (Municipal Act n. 6.323/88, regulated by Order 9425). These regulations established that those responsible for the building have to present to the local department of works (Secretaria Municipal de Obras e Viação – SMOV) a report on the structural stability of the marquees located on public areas every three years. This so-called “Marquee Act” was issued in response to two severe accidents that involved the fall of marquee sections downtown by the end of the 1980s and that had an important impact on the conservation status of the city’s marquee inventory. It was also a landmark in the history of the implementation of inspection laws in Brazil, as it influenced the adoption of similar legislation in other cities. After 30 years, it is important to evaluate its effects and to analyze the advances and obstacles to their application in order to guide other experiences. This is the main motivation of this research study. In order to complement and enrich the analyses, an indication of efficiency and quality of the marquee reports is pursued. Based on a parallel inspection of 135 structures, made by the author, with the aid of other researchers of the group LEME/UFRGS, data was collected to compare with those reported and filed at the local department of works (SMOV). Also, a survey of the public perception relative to the concepts associated with the implementation of inspection laws and preventive maintenance strategies was carried out, checking the acceptance of the costs associated with these strategies. This assessment was made using interviews and questionnaires applied to users of 24 buildings of the metropolitan region of Porto Alegre. The results showed that the population is aware of the risks and accepts the need for inspections, but that cost is still an obstacle. Aiming at using and consolidating the knowledge acquired through these analyses, the study ends proposing some guidelines considered useful for the implementation of façade element inspection laws.
95

Influência das características do peitoril no molhamento dos parâmetros próximos às janelas frente à chuva dirigida

Zucchetti, Lais January 2016 (has links)
A umidade é um dos principais agentes causadores de manifestações patológicas no ambiente construído, e, a chuva dirigida, é uma das principais fontes de umidade que afetam a durabilidade das fachadas das edificações. Desta forma, métodos vêm sendo desenvolvidos como forma de avaliação, entre eles se encontram os experimentais que buscam avaliar este fenômeno a partir da realização de ensaios. A pesquisa é motivada pela constatação da quase inexistência de estudos experimentais de quantificação de chuva dirigida, bem como pela identificação da problemática relacionada ao manchamento e infiltração de água na área próxima às janelas. Sendo assim, o objetivo principal desta pesquisa é identificar, com base em testes de chuva dirigida, a influência das características de projeção, com variações de 50 mm e 120 mm, de inclinação, com valores de 6% e 20%, e engaste lateral do peitoril, sem engaste e com engates de 100 mm, no molhamento da área de fachada localizada próxima às janelas. Este trabalho foi desenvolvido a partir da avaliação de nove modelos com dimensões 1,20m x 2,40m, sendo um modelo de referência sem peitoril, e outros oito englobando as diferentes configurações de projeção, inclinação e engastes laterais dos peitoris, em granito. As técnicas empregadas nas avaliações dos modelos foram a coleta de água da chuva nos paramentos dos modelos, registros de imagens termográficas por infravermelho, chuva colorida para identificação dos fluxos e registros fotográficos digitais A chuva simulada apresentava vazão total de 6 l/m, com diâmetros de gota que variavam de 0,86 mm – 1,45 mm com interceptação de velocidade de vento de 3,2 m/s, e, os testes foram desenvolvidos em quatro ciclos de 15 minutos de duração cada. Os resultados demonstraram que a utilização de prolongamentos laterais nos peitoris promoveram melhor desempenho dos modelos com relação ao descolamento da água da chuva das paredes, quando em comparação àqueles que não possuem esta configuração. Considerando a inclinação dos peitoris identificou-se que o valor de 6% permite, mesmo com a existência de um lacrimal na face inferior do peitoril, a percolação da água da chuva pela porção inferior deste elemento, com um gotejamento vertical. Nas configurações com 20% de inclinação do peitoril não se verifica este comportamento, contudo, o gotejamento ocorre no sentido da parede do modelo, direcionando parte do fluxo da chuva para a área localizada abaixo do peitoril, condicionando valores mais elevados de coleta de chuva. A projeção de 50 mm protege de forma menos eficiente as paredes dos modelos do molhamento pela chuva dirigida, gerando áreas protegidas menores e maiores valores de água coletada quando comparadas à projeção de 120 mm. / Moisture is one of the leading causes of pathological manifestations in buildings. Wind driven rain, is one of the main sources that affect the buildings facades durability. Thus, with the mean to evaluate this phenomenon, some experimental methods has been evaluated. The inexistence of experimental studies for wind driven rain quantification, motivated this research. Besides, this research aims to identify the staining and water seepage in the windows area problems. Thus, the main objective of this research is to identify, based on wind driven rain tests, the influence of geometrical characteristics of sills, in the wetness area located near windows. For this, there were developed sills with projection variations of 50 mm and 120 mm, inclinations of 6 % and 20 %, and sill without side extensions of window and 100 mm extensions. The experimental program contemplate the evaluation of nine wall models, with dimensions 1.20 m x 2.40 m, where a window were fixed and granite sills were installed, with the geometrical variations proposed. Simulated driving rain had total flow 6 l/m, with drop diameters ranging from 0.86 mm - 1.45 mm, with wind speed intercept of 3.2 m /s, and the tests were carried out in four cycles of 15 minutes each. There were collected rainwater on some controlled points of the walls models, besides infrared thermography images, colorful rain for identification of flows and digital photography. With the final results it was possible to conclude that the use of lateral extensions in windows sills promote better performance in the models, in relation to detachment of rainwater to the walls, when compared to sills without lateral extension. About sills inclination, it was found that the 6 % value results in a better behavior compared with 20% inclination. Finally, the windows sills with 120 mm protects more efficiently the models walls.
96

Avaliação da alteração de placas de rocha em fachada: estudo de caso / Evaluation of the alteration of plates of rock in facade case study

Lavínia de Vasconcelos Xavier Coêlho 05 April 2006 (has links)
o revestimento de uma fachada é em si um sistema de complexa resolução. Envolve uma série de variáveis como concepção de projeto, especificação de materiais, execução e manutenção. E, mesmo com todos os aspectos bem atendidos, não se pode determinar a vida útil do sistema, pois o meio tem forte interferência na sua durabilidade. O uso de rochas ornamentais como elemento de revestimento é outro item que necessita de atenção, uma vez que as rochas têm composição não controlável, são anisotrópicas em relação à resistência, são normalmente instáveis frente às intempéries e, quando em placas, suas espessuras têm sido reduzidas, fragilizando-as e diminuindo a proteção ao corpo da edificação. O presente trabalho trata de um estudo de caso onde foram usadas placas de rocha (200x400xl0 mm) do granito 'cinza andorinha', fixadas por ancoragem química com auxílio de grampos, em uma região com alta umidade, grande insolação, sujeita à névoa marinha e a poluição, Região Metropolitana de Recife. Através do método proposto por Lichtenstein (1986) foi feita a vistoria da fachada, na qual foram encontradas diversas patologias como desplacamento, infiltração e oxidação de grampos, e as placas de granito apresentavam alteração química, física e biológica, como mudança de tonalidade, cristalização de sais, eflorescência, oxidação de minerais, desagregação, fissuração e ataque por microorganismos. Como resultado, foram tecidas as seguintes considerações sobre a fachada: método construtivo, enfatizando a importância do projeto (especialmente do detalhe construtivo); especificação de materiais compatíveis às situações as quais são submetidos; execução e manutenção. Também a alteração do granito foi analisada. Aspectos como mudança de composição (oxidação da biotita) e da microestrutura (cristalização de sais) foram estudados com o intuito de contribuir para um uso mais racional deste material de construção específico / A facade coating is, by itself, a system of complex solution. It envelops a series of variables such as project conception, material specification, execution and maintenance. And, even with all aspects well attended, one can not determine the system useful life, because the environment has a strong influence in its durability. The use of dimension stones as coating element is another item that needs attention, since rocks have an uncontrollable composition, are anisotropic regarding resistance, are normally unstable before inclemency of the weather and being tile its thickness has been reduced, weakening them and diminishing protection to the building body. This work is about a case study where granite tiles (200x400xl0 mm), commercially named "cinza andorinha" have been used, fixed by chemical anchorage, held by clamps, in a region with high humidity, high isolation, subjected to sea mist and pollution, Recife (PE) metropolitan region. Through the method proposed by Lichtenstein (1986) it was made a facade inspection and several pathologies were found, such as tiles fall, infiltration and clamps oxidations and the granite tiles preseting chemical physical and biological alteration such as change in color, salt crystallization, efflorescence, mineral oxidation, disagregation, cracking, and microorganism aggression. As a result, the following cosiderations were done about the facade; constructive method, emphasizing the project importance (specially the constructive detail): material specification in compatibity with the situation subdued; execution and maintenance. Likewise, the granite alteration was analyzed. Features as change in composition (biotite oxidation) and in microstructure (salt crystallization) were studied aiming to contribute for a more rational use of this specific building material
97

Manifestações patológicas em conjuntos habitacionais: a degradação da fachadas

Celia Cavalcanti Braga 00 December 2010 (has links)
Os casos de deterioração de fachadas prediais no grande Recife e arredores têm sido objeto de atenção dos técnicos da construção civil no estado de Pernambuco. A presença de alterações visuais provocadas por manifestações patológicas (fungos, fissuras, manchas, etc.) nessas superfícies é um sinal de alerta de que o seu desempenho se encontra em declínio. O termo patologia, originário da medicina, tem se adequado ao quadro de doenças que têm se instalado nas edificações, de um modo geral, e principalmente as que estão expostas aos agentes degradantes naturais (vento, chuva, etc.): as fachadas. Este trabalho apresenta um estudo de caso das manifestações patológicas observadas nas fachadas de todos os edifícios com tipologia t3 (térreo + três) em três conjuntos habitacionais: Beira Rio, Casarão do Cordeiro e Abençoada por Deus, empreendidos pela Prefeitura da Cidade do Recife. Para tal, foram realizadas visitas e feito o levantamento, através da observação nas quatro fachadas desses conjuntos, das patologias relativas ao uso da pintura sobre revestimento de argamassa e sobre o tijolo. Foi utilizada, em primeiro lugar, uma adaptação do método de Lichtenstein (1986), que permitiu direcionar as várias etapas do trabalho que vão da vistoria do local até o diagnóstico, a conduta e a terapia. Em segundo lugar, dois outros métodos foram adotados para auxiliar no registro e contabilização das ocorrências patológicas identificadas: o método da incidência e o da intensidade. Foram observadas 172 fachadas e registradas as patologias nos planos verticais, desses conjuntos. São as seguintes as patologias: fungo, fissuras, empolamento da pintura, descoloração, manchas de corrosão, eflorescência, manchas na pintura, descolamento da pintura, desagregamento do tijolo e manchas de umidade no tijolo. Através da apresentação e discussão dos resultados obtidos pela comparação dos registros, pôde-se considerar o aparecimento das manifestações como decorrentes do projeto arquitetônico, da execução e da qualidade dos materiais de revestimento / Cases of deterioration in building facades in Recife and surroundings have been subject to the attention of technical construction in the state of Pernambuco. The presence of visual changes caused by pathological manifestations (fungi, cracks, stains, etc.) in these areas is a warning sign that their performance is in decline. The word pathology, originating in medicine, is used in civil engineering, by analogy, to determine diseases that are installed in several parts of the building, especially the most exposed to natural degrading agents (wind, rain, etc.): the facade. This work presents a study case of pathological problems surveyed in the facades of all buildings type t3(ground floor + three more floors) in three social housing projects: Beira Rio, Casarão do Cordeiro and Abençoada por Deus, supported by the Prefeitura da Cidade do Recife (Recife City Hall). Some pathologies related to the use of paint over mortar rendering or over brick only, were observed on the four facades of these buildings. First of all, the Lichtenstein method(1986) was used to guide the early stages of the work because it organizes the different steps to be taken all during the study, which range from the collection of data from the places visited to the diagnosis, conduct and therapy to be adopted. However, this method was slightly adapted for this study. Secondly, two other methods were used to help with recording and counting the pathologies observed on the facades: the methods of incidence and intensity. One hundred and seventy two facades were inspected and a series of problems on the vertical surfaces of these buildings was recorded. The pathologies were as follows: fungus, cracks, blisters on paint, discoloration, stains from corrosion, efflorescence, stain on paint, peeling paintwork, crumbling brickwork, moisture staining in the brickwork. After presenting and discussing the results obtained by comparing the data, it was concluded that the origin of these pathologies arose from the architectural planning, the way it was implemented and the quality of the materials used to clad the walls
98

Modelo de apoio à decisão para seleção de tecnologias de revestimento de fachadas / Decision aid model for facades cladding technologies selection

Gondim, Ivo Almino January 2007 (has links)
O interesse em reduzir manifestações patológicas, o possível impacto sobre a satisfação dos clientes e a busca por redução de custos são alguns dos fatores que, durante as fases de projeto arquitetônico, podem tornar complexa a decisão referente à seleção de uma tecnologia de revestimento de fachada. Diante disso, o presente trabalho tem como objetivo propor um modelo de apoio à decisão para seleção de tecnologias de revestimento de fachadas. O desenvolvimento do trabalho envolveu quatro fases de pesquisa. Na primeira, foi realizado um estudo sobre como são tomadas as decisões, com identificação dos atores envolvidos, caracterização das diferenças entre as alternativas potenciais e definição dos contornos da problemática de decisão. Na segunda fase, estruturou-se um modelo de decisão multicritério adequado para o contexto de decisão de interesse. O modelo desenvolvido leva em conta aspectos considerados importantes por profissionais com ampla experiência e incorpora características positivas identificadas em outros modelos encontrados na prospecção da bibliografia existente na área. Em seguida, na terceira fase, foram efetuados testes de aplicação do modelo, com seis decisores, tomando como referência um cenário de decisão fictício, estabelecido levando em conta as características da cidade de Fortaleza. A captura do sistema de valores dos decisores foi efetuada através de formulários. Os resultados oriundos dos formulários, com o auxílio de software e planilhas eletrônicas, serviram de base para que o modelo apresentasse suas recomendações. Durante as aplicações, os resultados parciais das capturas de conhecimento eram discutidos com os participantes do teste e analisados pelo pesquisador, com o objetivo de verificar se o procedimento deveria sofrer refinamentos ou ajustes. Por fim, na quarta fase, foi realizada uma validação qualitativa do modelo, através de entrevistas e formulários nos quais se discutia se a previsão do modelo seria útil e se coadunava com as expectativas dos decisores. Os resultados obtidos indicam que existe viabilidade para aplicação do modelo proposto, pois o mesmo foi considerado útil e válido pelos decisores dentro do seu contexto de aplicação. Acredita-se que, com o desenvolvimento e aperfeiçoamento da ferramenta proposta, a mesma venha a contribuir de forma significativa para apoiar escolhas de decisores na construção civil, em especial, em situações em que existem dúvidas sobre a tecnologia mais apropriada. Mais ainda, ao estruturar o processo de decisão, a mesma permite que se discutam os parâmetros e valores que influenciam cada decisão, permitindo uma melhor reflexão e consenso entre os intervenientes. / Interests in decreasing pathological manifestations, improve customers’ satisfaction and promote cost reductions are important considerations that, during the design building phase, may increase the complexity of the decision regarding facades cladding technology. The main purpose of the present work is to suggest a decision aid model for technological decisions, in the choice of facades cladding technologies. The research development involved four phases. In the first one, it was studied about how decisions are taken, with stakeholders’ identification, potential action characterization, and problematic definition. In the second phase, it was structured a model in accordance with context interests. The decision aid model considers aspects judged as important by experienced professionals and considers positive characteristics identified by models found in the literature of the area. In the third phase, simulation tests were realized with six decision makers, considering a fictitious project in Fortaleza city. Using formularies, individual values were captured from decision makers. The results collected with the aid of software and electronic sheets served as the basis for model recommendations. During the application of the model, partial results were discussed with decisionmakers and analyzed by the researcher so that they could be refined or adjusted. Finally, in the fourth phase, a qualitative validation was carried through interviews and formularies. This phase verified if the decision aid model was considered useful and valid by decision-makers. It was shown that the proposed tool can significantly contribute to help decision makers in the selection of facades cladding technologies, especially in complex situations. More yet, it can help to structure the decision process, becoming an important the tool for discussing the parameters and values influencing decisions, and helping stakeholders to reach a consensed solution.
99

Correlação numérico- experimental entre o método dos elementos de contorno e termografia aplicados a placas de argamassa

Guimarães, Denise Cardoso 02 June 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2017. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2017-07-14T14:44:35Z No. of bitstreams: 1 2017_DeniseCardosoGuimaraes.pdf: 5529443 bytes, checksum: e61b9ec68c6fedba006aef68e12b3e02 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2017-09-11T22:50:20Z (GMT) No. of bitstreams: 1 2017_DeniseCardosoGuimaraes.pdf: 5529443 bytes, checksum: e61b9ec68c6fedba006aef68e12b3e02 (MD5) / Made available in DSpace on 2017-09-11T22:50:20Z (GMT). No. of bitstreams: 1 2017_DeniseCardosoGuimaraes.pdf: 5529443 bytes, checksum: e61b9ec68c6fedba006aef68e12b3e02 (MD5) Previous issue date: 2017-09-11 / As fachadas são elementos que desempenham um papel muito importante nas edificações, pois são responsáveis por garantir e controlar com eficácia as trocas de calor, ar e luminosidade existentes entre o interior e exterior da edificação, além da qualidade visual (estética da edificação). Sabe-se que, ao longo do tempo, os revestimentos das fachadas estão expostos as intempéries, as quais podem gerar danos ou anomalias em sua estrutura, como descolamento de cerâmicas.Por outro lado, a busca por resultados com menor custo, o uso de processos não-destrutivos, bem como o uso de procedimentos e ferramentas numéricas que permitam análises rápidas, como o Método dos Elementos de Contorno (MEC), têm se tornado importantes tópicos neste campo de pesquisa. Neste contexto, o presente trabalho tem como objetivo estudar a influência da profundidade das fissuras presentes nos revestimentos de fachada, através da modelagem do fluxo de calor de uma placa de argamassa contendo duas fissuras, submetida a um ciclo de aquecimento direto. Para tanto se realizou uma modelagem numérica, onde a interface gráfica chamada BEMLAB2D foi responsável pela geração da malha (frontal e lateral) em elementos de funcionalidade constante, e um programa de análises, escrito em MATLAB, para problemas de Potencial via MEC com Sub-região, responsável pelos cálculos de temperatura e fluxo em pontos do contorno e interior. Observando os resultados obtidos através da modelação numérica e comparando com os resultados experimentais, constata-se que é possível detectar diferenças no comportamento do fluxo de calor devido à profundidade das fissuras, o que demonstra também a acurácia e eficiência da análise junto aos dados experimentais. / The facades are elements that perform an important role in the buildings, either for ensuring and effectively control the heat, air and light changes between the interior and exterior of the building, as well as the visual quality (building aesthetics). Over time, the outer coating is exposed to the weather, which can cause damage or structural anomalies as detachment of ceramics, for example. On the other hand, the search for results at lower cost, the use of non-destructive processes, and the use of procedures and numerical tools which enable quick and efficient analyzes, such as the Boundary Element Method (BEM), have become an important topics in scientific research. In this context, the present work aims to study the influence of cracks depth on facade coatings by modeling the heat flow of a mortar plate containing two cracks, subjected to a direct heating cycle. Here, the methodology consists of a numerical modeling, based on data from thermography extracted from experimental tests on cracked mortar plates, where two programs has been used: the BEMLAB2D GUI for modeling and boundary element mesh generation, as well as an analysis program, written in MATLAB, for Potential problems via BEM with Sub-region, for calculations of temperature and flow at boundary and internal points. Observing the results of numerical modeling and comparing the experimental results, it is found that it is possible to detect differences in the heat flow behavior due to the cracks depth, which also demonstrates the accuracy and efficiency of the methodology adopted between numerical and experimental analysis.
100

Influência das características do peitoril no molhamento dos parâmetros próximos às janelas frente à chuva dirigida

Zucchetti, Lais January 2016 (has links)
A umidade é um dos principais agentes causadores de manifestações patológicas no ambiente construído, e, a chuva dirigida, é uma das principais fontes de umidade que afetam a durabilidade das fachadas das edificações. Desta forma, métodos vêm sendo desenvolvidos como forma de avaliação, entre eles se encontram os experimentais que buscam avaliar este fenômeno a partir da realização de ensaios. A pesquisa é motivada pela constatação da quase inexistência de estudos experimentais de quantificação de chuva dirigida, bem como pela identificação da problemática relacionada ao manchamento e infiltração de água na área próxima às janelas. Sendo assim, o objetivo principal desta pesquisa é identificar, com base em testes de chuva dirigida, a influência das características de projeção, com variações de 50 mm e 120 mm, de inclinação, com valores de 6% e 20%, e engaste lateral do peitoril, sem engaste e com engates de 100 mm, no molhamento da área de fachada localizada próxima às janelas. Este trabalho foi desenvolvido a partir da avaliação de nove modelos com dimensões 1,20m x 2,40m, sendo um modelo de referência sem peitoril, e outros oito englobando as diferentes configurações de projeção, inclinação e engastes laterais dos peitoris, em granito. As técnicas empregadas nas avaliações dos modelos foram a coleta de água da chuva nos paramentos dos modelos, registros de imagens termográficas por infravermelho, chuva colorida para identificação dos fluxos e registros fotográficos digitais A chuva simulada apresentava vazão total de 6 l/m, com diâmetros de gota que variavam de 0,86 mm – 1,45 mm com interceptação de velocidade de vento de 3,2 m/s, e, os testes foram desenvolvidos em quatro ciclos de 15 minutos de duração cada. Os resultados demonstraram que a utilização de prolongamentos laterais nos peitoris promoveram melhor desempenho dos modelos com relação ao descolamento da água da chuva das paredes, quando em comparação àqueles que não possuem esta configuração. Considerando a inclinação dos peitoris identificou-se que o valor de 6% permite, mesmo com a existência de um lacrimal na face inferior do peitoril, a percolação da água da chuva pela porção inferior deste elemento, com um gotejamento vertical. Nas configurações com 20% de inclinação do peitoril não se verifica este comportamento, contudo, o gotejamento ocorre no sentido da parede do modelo, direcionando parte do fluxo da chuva para a área localizada abaixo do peitoril, condicionando valores mais elevados de coleta de chuva. A projeção de 50 mm protege de forma menos eficiente as paredes dos modelos do molhamento pela chuva dirigida, gerando áreas protegidas menores e maiores valores de água coletada quando comparadas à projeção de 120 mm. / Moisture is one of the leading causes of pathological manifestations in buildings. Wind driven rain, is one of the main sources that affect the buildings facades durability. Thus, with the mean to evaluate this phenomenon, some experimental methods has been evaluated. The inexistence of experimental studies for wind driven rain quantification, motivated this research. Besides, this research aims to identify the staining and water seepage in the windows area problems. Thus, the main objective of this research is to identify, based on wind driven rain tests, the influence of geometrical characteristics of sills, in the wetness area located near windows. For this, there were developed sills with projection variations of 50 mm and 120 mm, inclinations of 6 % and 20 %, and sill without side extensions of window and 100 mm extensions. The experimental program contemplate the evaluation of nine wall models, with dimensions 1.20 m x 2.40 m, where a window were fixed and granite sills were installed, with the geometrical variations proposed. Simulated driving rain had total flow 6 l/m, with drop diameters ranging from 0.86 mm - 1.45 mm, with wind speed intercept of 3.2 m /s, and the tests were carried out in four cycles of 15 minutes each. There were collected rainwater on some controlled points of the walls models, besides infrared thermography images, colorful rain for identification of flows and digital photography. With the final results it was possible to conclude that the use of lateral extensions in windows sills promote better performance in the models, in relation to detachment of rainwater to the walls, when compared to sills without lateral extension. About sills inclination, it was found that the 6 % value results in a better behavior compared with 20% inclination. Finally, the windows sills with 120 mm protects more efficiently the models walls.

Page generated in 0.1135 seconds