• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 243
  • 11
  • 11
  • 11
  • 11
  • 10
  • 6
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 255
  • 130
  • 110
  • 98
  • 68
  • 58
  • 58
  • 57
  • 49
  • 44
  • 38
  • 29
  • 29
  • 29
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Integração financeira e a estimação do custo de capital próprio no âmbito do novo contexto tarifário da telefonia fixa no Brasil

Bertini, Tulio Carné January 2007 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Sócio-Econômico. Programa de Pós-Graduação em Economia / Made available in DSpace on 2012-10-23T01:15:48Z (GMT). No. of bitstreams: 1 247584.pdf: 1031683 bytes, checksum: 0930a1c6a94a4c3d4cd54787128fcf2c (MD5) / Esta pesquisa mostra a importância da estimação do custo de capital próprio para o novo contexto regulatório do setor de telefonia fixa do Brasil. Ademais, analisa a evolução da integração financeira do mercado de capitais brasileiro no período de 1994 a 2000 e propõe um novo modelo de avaliação de custo de capital próprio para mercados emergentes. Para evidenciar a evolução da integração do mercado brasileiro, é utilizado o índice FOR proposto por Edison e Warnock (2001) e feita uma comparação, em dois períodos, da relação entre a razão de volatilidades dos retornos dos índices de mercado (carteira nacional e global) e o coeficiente de correlação entre os retornos desses mercados. A proposta do novo modelo de avaliação de custo de capital próprio para mercados emergentes parte do pressuposto de que os mercados são parcialmente integrados. Esse modelo é composto por um índice criado para capturar o potencial de cada ativo para a diversificação dos riscos de uma carteira de mercado global. Para o cálculo do índice são utilizadas ações de empresas do setor de telefonia fixa e um índice setorial de telefonia do Brasil. Os resultados obtidos evidenciam, no período de 1994 a 2000, o aumento da integração financeira do mercado de capitais brasileiro e a manutenção das condições para a diminuição do custo de capital próprio nesse mercado. Os resultados do cálculo do índice que compõe o novo modelo mostraram-se coerentes com a capacidade dos ativos analisados em reduzir o risco de uma carteira globalmente diversificada. This research shows the importance of the assessment of cost of equity capital within the new regulatory context for fixed telephony in Brazil. The evolution of the Brazilian equity market financial integration in the period between 1994 and 2000 is analyzed, and a new equity assessment model for emergent markets is suggested. In order to demonstrate the Brazilian market integration evolution, the index FOR (proposed by Edison e Warnock, 2001) is employed. In addition, a two-period comparison is drawn, between the relation of the market return index volatility ratio (national and global market) and the correlation coefficient between the returns of these markets. The new equity cost assessment model suggested for the emergent markets assumes that such markets are partially integrated. This model is composed of an index created to capture the potential of each equity to diversify the risks of the global portfolio. For the index calculation, fixed telecommunications company equities and a specific Brazilian telecommunications index are used. The results show that, during the period from 1994 to 2000, financial integration increased in the Brazilian capital market, while the conditions for reduction of the cost of equity within the market remained the same. The results of the index calculation of the new model are consistent with the analyzed equity capacity to reduce the risk of a diversified global portfolio.
2

Avaliação do Protocolo Com Atividade Fixa Em Portadores da Doença de Plummer Pós Radioiodoterapia (RIT)

MENDONÇA, Keyla Mary Cavalheiro 10 August 2011 (has links)
Submitted by Eduarda Figueiredo (eduarda.ffigueiredo@ufpe.br) on 2015-03-13T12:53:09Z No. of bitstreams: 2 Dissertação Keyla Mendonça.pdf: 1474518 bytes, checksum: 9c5baef3088dddf292044a4494fe7f6c (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-13T12:53:09Z (GMT). No. of bitstreams: 2 Dissertação Keyla Mendonça.pdf: 1474518 bytes, checksum: 9c5baef3088dddf292044a4494fe7f6c (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2011-08-10 / A terapia com 131I é o tratamento mais prescrito para pacientes adultos com doença de Plummer, consolidando-se por ser um tratamento efetivo, de baixo custo e seguro. Há diferentes protocolos em uso para se determinar a atividade radioativa (dose) a ser administrada no tratamento com 131I dessa doença, mas nem todos consideram a dose absorvida na tireoide. Estudos mostram que essa prática deveria se basear na captação individual do 131I, na biocinética do paciente e na massa da tireóide. Estudos que se contrapõem à essa idéia, mostrando que a utilização de atividades calculadas em função da massa glandular e pela captação do iodo não oferece vantagens em relação às atividades fixas, ocasionando seu custo operacional. O objetivo deste trabalho é avaliar a eficiência do protocolo utilizado em tratamento da doença de Plummer com atividade fixa, 1110 megabequeréis (MBq) o que equivale a (30mCi) de 131I, considerando a relação entre a atividade efetiva e a atividade prescrita empiricamente, bem como o comportamento clínico da DP durante dois anos de tratamento após a administração da mesma, levando em conta as variáveis idade, massa corporal, TSH e T4. Este estudo foi realizado considerando informações de 54 pacientes portadores da doença de Plummer, os quais foram divididos em três grupos conforme informações nos prontuários. Foram elas: a evolução clínica laboratorial, a captação máxima do 99m Tc, para realização do calculo 131I, e a massa da tireoide. Para o cálculo da atividade foi o utilizado o método do Medical Internal Radiation Dosimetry (MIRD) (MANZANO et al., 2002). Portanto, o protocolo que utiliza a atividade administrada fixa apresentou uma boa eficiência no tratamento com 131I para os pacientes com doença de Plummer. Em comparação com atividade efetiva (calculada) os resultados mostraram que o protocolo que utiliza atividade administrada fixa, apresentou discrepâncias com relação às atividades que deveriam ser administradas levando em conta os parâmetros dosimétricos; ora o paciente recebia atividade abaixo da necessária, ora acima da necessária. As variáveis estudadas influenciaram no resultado do tratamento.
3

Resistência de união entre três sistemas cerâmicos de uso odontológico com uma liga de paládio-prata. / Bond strength of three ceramic systems and a palladium-silver alloy

Scolaro, Juliano Milczewsky 12 April 2000 (has links)
Avaliou-se a resistência ao cisalhamento da união metalocerâmica, de três diferentes sistemas cerâmicos de uso odontológico (Ceramco, Noritake e Vita VMK-68) aplicados sobre uma liga de paládio-prata (Pors-on 4), utilizando-se para isto, forças de compressão. Utilizando-se a metodologia descrita por CHONG; BEECH; CHEM19, modificada por BATISTA7, foram confeccionados 30 padrões metálicos divididos em três grupos de dez espécimes, sob os quais foi aplicada a cerâmica. Para a confecção dos corpos de prova, aplicação da cerâmica e realização dos testes de cisalhamento, utilizou-se uma matriz de aço inoxidável, em formato cilíndrico, com uma perfuração central de tamanho predeterminado, obtendo-se assim, corpos de prova padronizados. Após a fundição os padrões metálicos foram jateados com óxido de alumínio 50µm e levados ao forno sem vácuo a 980ºC por dez minutos para a oxidação prévia. Recolocados novamente no interior da matriz, receberam duas camadas de cerâmica opaca e duas camadas de cerâmica de corpo. Em seguida foram realizados os testes de resistência ao cisalhamento em uma máquina de tração e compressão, utilizando-se uma célula de carga de 100Kgf e velocidade de 0,5mm/min. As médias dos valores de resistência de união obtidas foram de 28,212MPa para o sistema Ceramco, 28,963MPa para o Noritake e 24,110MPa para o Vita VMK-68. Quando submetidos à análise de variância a um critério, não foram observadas diferenças estatisticamente significantes, o que nos levou à conclusão de que todos os sistemas possuem uma características de união metalocerâmica satisfatórias quando utilizados em conjunto com a liga selecionada. Além disso, os resultados são semelhantes aos descritos na literatura e se encontram além das forças necessárias para provocar a falha dos mesmos. / The purpose of this study was to evaluate the bond strength of a palladium-silver alloy (Pors-on 4) to three ceramic systems (Ceramco, Noritake and Vita VMK-68) using shear forces at the metal-ceramic interface. The method used for the tests was that developed by CHONG, BEECH e CHEM19, modified by BATISTA7. A stainless steel cylindric matrix was used for preparation of the metal patterns, application of ceramic and to perform the shear tests. Thirty specimens were prepared consisting of a palladium-silver alloy cylinder with two layers of opaque porcelain covered by two layers of body porcelain. The shear tests were perfomed in a universal testing machine using a load cell of 100kgf at a cross head speed of 0,5mm/min. The mean shear strength values for the three ceramic systems were: 28.212MPa (Ceramco), 28.963MPa (Noritake) and 24.110MPa Vita VMK-68). No statistically significant diferences were found among the groups what led us to conclude that the three ceramic systems are suitable for use in combination with the selected alloy.
4

Confiabilidade e modos de fratura de próteses fixas implanto-suportadas metalocerâmicas e em zircônia

Bonfante, Estevam Augusto 14 May 2009 (has links)
A falha coesiva na porcelana de revestimento de próteses com infraestruturas de policristais de zircônia tetragonal estabilizada por ítrio (PZT-Y) tem causado elevadas taxas clínicas de fracassos. No presente estudo avaliou-se a confiabilidade e modos de fratura de próteses fixas implanto-suportadas confeccionadas em uma liga de Paládio-Prata (PdAg) e em PZT-Y, submetidas à fadiga acelerada progressiva. Embebeu-se análogos de implantes em uma resina acrílica. Infra-estruturas em PZT-Y e PdAg (n = 21/ grupo) foram fabricadas, revestidas com porcelana, cimentadas e submetidas a uma carga estática (n = 3/ grupo) para obtenção dos valores de resistência à fratura. Em seguida, 18 espécimes de cada grupo foram distribuídos ao longo de 3 perfis de estresse progressivo e submetidos à fadiga em água com a carga aplicada na cúspide vestibular do pôntico. Encontrou-se no grupo PdAg um modo de fratura incluindo trincas flexurais na área do conector competindo com a falha coesiva da porcelana, enquanto que as próteses em PZT-Y apresentaram falha coesiva na porcelana de revestimento. O cálculo da confiabilidade (Alta Pro, ReliaSoft, intervalo de confiança de 90 %, bilateral) revelou a ausência de diferença significativa para a finalização de uma missão de 50.000 ciclos a 300 N entre as próteses em PdAg e PZT-Y. Contudo, a confiabilidade reduziu significativamente para o grupo PZT-Y na finalização de uma missão de 100.000 ciclos a 300 N enquanto que permaneceu a mesma para o grupo PdAg. Concluiu-se que para uma missão de 100.000 ciclos a 300 N a confiabilidade é mais alta para a prótese metalocerâmica quando comparada à em PZT-Y. Os modos de fratura diferiram entre os grupos. / Statement of problem: chipping within veneering porcelain has resulted in high clinical failure rates for implant-supported zirconia (Y-TZP) bridges. This study evaluated the reliability and failure modes of mouth-motion step-stress fatigued implant-supported Y-TZP versus Palladium-Silver alloy (PdAg) three-unit bridges. Methods: Implant-abutment replicas were embedded in polymethylmethacrylate resin. Y-TZP and PdAg frameworks, of similar design (n=21 each), were fabricated, veneered, cemented (n=3 each), and Hertzian contact tested to obtain ultimate failure load. In each framework group eighteen specimens were distributed across 3 step-stress profiles and mouth-motion cyclically loaded according to the profile on the lingual slope of the buccal cusp of the pontic. Results: PdAg failures included competing flexural cracking at abutment and/or connector area and chipping, whereas Y-TZP presented predominantly cohesive failure within veneering porcelain. Including all failure modes, the reliability (2-sided at 90% confidence intervals) for a mission of 50,000 and 100,000 cycles at 300 N load was determined (Alta Pro, Reliasoft). No difference in reliability was observed between groups for a mission of 50,000. Reliability remained unchanged for a mission of 100,000 for PdAg, but significantly decreased for Y-TZP. Conclusion: Higher reliability was found for PdAg for a mission of 100,000 cycles at 300N. Failure modes differed between materials.
5

[en] CORPORATE BONDS ANALYSIS: THE CASE OF PETROBRAS USD 11 BILLION BONDS ISSUE THE BIGGEST FOR EMERGING MARKETS / [pt] ANÁLISE DE BONDS CORPORATIVOS: O CASO DA EMISSÃO DE USD 11 BILHÕES DA PETROBRAS - A MAIOR DA HISTÓRIA PARA MERCADOS EMERGENTES

MAURÍCIO PIRAGIBE DE CARVALHO FARIA 03 August 2015 (has links)
[pt] Este trabalho analisará uma das maiores emissões de bonds de todos os tempos, a emissão de USD 11 bilhões de bonds da Petrobras que aconteceu em maio de 2013. Além de ser a maior transação da história para países emergentes até hoje, a emissão também foi feita em hora oportuna quando a Petrobras aproveitou uma excelente janela e mercado para fazer a emissão. A repercussão da transação também foi excelente tendo sido veiculada em vários meios de comunicação. O trabalho relatará do anúncio, precificação e lançamento da emissão que foi muito bem recebida pelo mercado financeiro. / [en] This paper will examine one of the largest bond issue ever, the USD 11 billion Petrobras bonds issue by Petrobras, the brazilian oil company, held in May 2013. Besides being the largest transaction in history for emerging countries until today, the issue has also been taken in proper time when Petrobras took an excellent market window to make the issue. The effect of the transaction was also great having been conveyed in various media vehicles. The work will speak with the market s announce, pricing and launch the issue which was very well received by the financial market.
6

Análise de retorno dos fundos de renda fixa brasileiros através de indicadores de mercado

Rassier, Leandro Hirt January 2004 (has links)
Este trabalho estuda o comportamento do retorno dos fundos de Investimento de Renda Fixa no Brasil a partir de um modelo baseado na hipótese de que os fundos de Investimento Financeiro (FIF’s) e os Fundos de Aplicação em Cotas de FIF’s (FAC’s) estão diretamente ligados às seguintes variáveis: i) Bolsa (IBOVESPA), ii) Taxa de Juros (CDI) e iii) Câmbio (Dólar). No presente estudo, são investigados basicamente dois aspectos: a) a existência de uma relação entre a variação dos indicadores financeiros e a variação do retorno dos fundos e b) a alteração dos fatores explicativos do retorno dos fundos ao longo dos meses. Os resultados obtidos mostram que a grande maioria dos fundos obteve os retornos explicados por um, dois ou três benchmarks; logo, é possível interpretar a categoria de ativos de um fundo como exposição do desempenho de seu benchmark. No entanto, foi constatado que a escolha do benchmark mais adequado para um fundo de investimento depende do conhecimento da composição da carteira desse fundo. Assim, através de uma análise criteriosa dessas informações, o investidor deve estar convicto de que a política de investimentos de um determinado fundo o enquadra em uma determinada categoria. Além disso, ele deve ter a segurança necessária e suficiente de estar classificando seu(s) fundo(s) na categoria certa, e por via de conseqüência, comparar sua performance com base em seu risco associado, de forma justa e compatível com seu semelhante.
7

Procedimento para a definição de indicadores para a avaliação de desempenho : o caso da regulação da telefonia fixa no Brasil

Marchesan, Cristina Heilmann January 2005 (has links)
A diversificação de produtos e serviços e a competição entre milhares de empresas no mercado atual exige das empresas uma postura mais proativa e com flexilidade de adaptação rápida a novos parâmetros e informações. Inserido neste cenário, o setor público teve que se adequar às transformações, privatizando vários setores e criando agências reguladoras para manter a competição e o nível de qualidade de serviços/produtos produzidos por estes setores. Um dos métodos mais aplicados nos últimos anos no setor privado para gestão e avaliação de desempenho é o Balanced Scorecard (BSC). Assim, o objetivo central deste trabalho é propor um procedimento para definição de indicadores e analisar e melhorar o sistema de avaliação de desempenho de empresas. Os conceitos do BSC são utilizados no procedimento proposto. Apresenta-se uma aplicação deste procedimento no sistema de avaliação de desempenho que a agência reguladora brasileira do setor de telefonia utiliza para regular o setor de telefonia fixa. Como resultado da aplicação do método proposto, desenvolve-se um conjunto de indicadores mais equilibrado e estruturado para a regulação específica do setor de telefonia fixa do Brasil, o qual apresenta o alinhamento da avaliação de desempenho com a missão e objetivos da ANATEL como reguladora do setor.
8

Análise de retorno dos fundos de renda fixa brasileiros através de indicadores de mercado

Rassier, Leandro Hirt January 2004 (has links)
Este trabalho estuda o comportamento do retorno dos fundos de Investimento de Renda Fixa no Brasil a partir de um modelo baseado na hipótese de que os fundos de Investimento Financeiro (FIF’s) e os Fundos de Aplicação em Cotas de FIF’s (FAC’s) estão diretamente ligados às seguintes variáveis: i) Bolsa (IBOVESPA), ii) Taxa de Juros (CDI) e iii) Câmbio (Dólar). No presente estudo, são investigados basicamente dois aspectos: a) a existência de uma relação entre a variação dos indicadores financeiros e a variação do retorno dos fundos e b) a alteração dos fatores explicativos do retorno dos fundos ao longo dos meses. Os resultados obtidos mostram que a grande maioria dos fundos obteve os retornos explicados por um, dois ou três benchmarks; logo, é possível interpretar a categoria de ativos de um fundo como exposição do desempenho de seu benchmark. No entanto, foi constatado que a escolha do benchmark mais adequado para um fundo de investimento depende do conhecimento da composição da carteira desse fundo. Assim, através de uma análise criteriosa dessas informações, o investidor deve estar convicto de que a política de investimentos de um determinado fundo o enquadra em uma determinada categoria. Além disso, ele deve ter a segurança necessária e suficiente de estar classificando seu(s) fundo(s) na categoria certa, e por via de conseqüência, comparar sua performance com base em seu risco associado, de forma justa e compatível com seu semelhante.
9

Procedimento para a definição de indicadores para a avaliação de desempenho : o caso da regulação da telefonia fixa no Brasil

Marchesan, Cristina Heilmann January 2005 (has links)
A diversificação de produtos e serviços e a competição entre milhares de empresas no mercado atual exige das empresas uma postura mais proativa e com flexilidade de adaptação rápida a novos parâmetros e informações. Inserido neste cenário, o setor público teve que se adequar às transformações, privatizando vários setores e criando agências reguladoras para manter a competição e o nível de qualidade de serviços/produtos produzidos por estes setores. Um dos métodos mais aplicados nos últimos anos no setor privado para gestão e avaliação de desempenho é o Balanced Scorecard (BSC). Assim, o objetivo central deste trabalho é propor um procedimento para definição de indicadores e analisar e melhorar o sistema de avaliação de desempenho de empresas. Os conceitos do BSC são utilizados no procedimento proposto. Apresenta-se uma aplicação deste procedimento no sistema de avaliação de desempenho que a agência reguladora brasileira do setor de telefonia utiliza para regular o setor de telefonia fixa. Como resultado da aplicação do método proposto, desenvolve-se um conjunto de indicadores mais equilibrado e estruturado para a regulação específica do setor de telefonia fixa do Brasil, o qual apresenta o alinhamento da avaliação de desempenho com a missão e objetivos da ANATEL como reguladora do setor.
10

Análise comparativa das tensões e deformações entre próteses implantossuportadas de três elementos com dois ou três pilares / Stress and strain distribution around dental prostheses supported by two or tree implants

Nishioka, Gabriela Nogueira de Melo [UNESP] 30 November 2016 (has links)
Submitted by GABRIELA NOGUEIRA DE MELO NISHIOKA null (gabriela.nogueira.nishioka@gmail.com) on 2017-01-19T13:54:56Z No. of bitstreams: 1 Gabriela Nishioka.pdf: 2137589 bytes, checksum: 86ee2622125d947111a3e7089e8be313 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2017-01-24T16:20:28Z (GMT) No. of bitstreams: 1 nishioka_gnm_me_sjc.pdf: 2137589 bytes, checksum: 86ee2622125d947111a3e7089e8be313 (MD5) / Made available in DSpace on 2017-01-24T16:20:28Z (GMT). No. of bitstreams: 1 nishioka_gnm_me_sjc.pdf: 2137589 bytes, checksum: 86ee2622125d947111a3e7089e8be313 (MD5) Previous issue date: 2016-11-30 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O objetivo deste estudo foi avaliar as tensões e deformações in vitro, por meio da fotoelasticidade e da extensometria, em próteses parciais fixas implantossuportadas de três elementos variando o número de pilares: dois e três. O primeiro bloco de poliuretano (modelo mestre 1) recebeu três implantes e o segundo (modelo mestre 2) recebeu dois implantes, todos de hexágono externo. Em seguida, os modelos mestre foram duplicados em resina fotoelástica. Pilares protéticos microunit foram conectados aos implantes com torque de 20 Ncm. Sobre os pilares protéticos dos modelos mestre foram parafusados cilindros plásticos, que receberam estruturas em padrões de resinas, os quais foram fundidos em liga de Ni-Cr (n=10). Quatro extensômetros foram colados na superfície de cada bloco de poliuretano, tangenciando os implantes. Nos modelos mestre e nos modelos fotoelásticos, cada estrutura metálica foi parafusada sobre os pilares protéticos com torque de 10 Ncm. Os dados obtidos na extensometria foram submetidos aos testes estatísticos RM ANOVA e Tukey (5%). As franjas isocromáticas obtidas nos modelos fotoelásticos após cada condição de carga foram registradas com uma câmera digital, visualizadas em um programa de computador e comparadas qualitativamente. Resultados: Houve uma diferença estatística significante entre a quantidade de suporte de uma prótese fixa (p=0,001). Os resultados revelaram que três implantes apresentaram uma melhor distribuição das cargas em qualquer ponto analisado e que a região de pôntico da prótese é o local que apresenta maior diferença na quantidade de deformação (2326,95με para 2 implantes e 1006,57με para 3 implantes). Nas imagens fotoelásticas foi possível visualizar uma melhor distribuição das tensões no bloco com 3 implantes. Conclusão: Ambos os métodos apresentaram resultados similares. Esse estudo sugere que uma prótese fixa pode ser suportada por 2 ou 3 implantes. / The present study used photoelastic and strain gauge analysis to compare stress and microstrain to perform an in vitro evaluation of the effect of the numbers of support in a implant-supported fixed partial prostheses with tree elements. The first polyurethane block (master model 1) will contain three implants and the second block (model 2) two of them, all implants have a external hexagon. Then, the master models were duplicated in photoelastic resin. Microunit abutments were connected to the implants and received a 20 Ncm torque. Over the master model plastic prosthetic cylinders were screwed the abutments that received standard patterns cast in Ni-Cr alloy (n=10). Four strain gauges (SG) were bonded in the surface of the block, tangentially to the lateral implants. On the master model and photoelastic model, each metallic structure were screwed onto the abutments with a 10 Ncm torque. The data obtained from the strain gauge were analyzed statistically by RM ANOVA and Tukey's test, with a 5% conventional level of significance. The isochromatic fringes obtained in the photoelastic models after each load condition were recorded with a digital camera, visualized with software to facilitate qualitative analysis. Results: There was statistically significant differences in support of FPD( p=0,001).The results demonstrated that 3 implants has higher stress distribution and in the pontic of FPD we found higher stress (2326,95με in 2 implants and 1006,57με in 3 implants).In photoelastic images, 3 implants presented better stress distribution than 2 implants. Conclusions: Both methods found similar results. This study suggests that FPD can be supported by two or three implants.

Page generated in 0.954 seconds