• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 243
  • 11
  • 11
  • 11
  • 11
  • 10
  • 6
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 255
  • 130
  • 110
  • 98
  • 68
  • 58
  • 58
  • 57
  • 49
  • 44
  • 38
  • 29
  • 29
  • 29
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação da resistência à fratura por compressão de infraestruturas de próteses fixas de três elementos (1º pré-molar a 1º molar) confeccionadas com cerâmicas IPS Empress II e In-Ceram

Mendes, Vagner 27 March 2003 (has links)
O apelo estético tem obrigado as indústrias de materiais odontológicos e os pesquisadores a buscar materiais que apresentem, além da estética, resistência suficiente para resistir às forças mastigatórias. Assim o objetivo deste trabalho foi comparar a resistência à fratura por compressão axial de infraestruturas de próteses fixas de três elementos (1º pré-molar a 1º molar) confeccionadas com dois sistemas de porcelanas, In-Ceram Zircônia e IPS Empress 2. Foram selecionados 20 pré-molares e 20 molares que receberam preparos tipos “inlays" com caixas oclusais e proximais (DO nos pré-molares e MO nos molares), tendo-se o cuidado de obter caixas proximais com 4,0 mm de altura por 4,0 mm de largura. Após obtenção dos modelos em gesso, as infraestruturas foram confeccionadas em laboratórios credenciados pelos fabricantes de acordo com o protocolo determinado para cada material. A cimentação foi feita com o cimento Variolink II. Após a cimentação, as infraestruturas foram submetidas a teste de carga por compressão pela ação de uma ponta de aço com 2,0 mm de diâmetro, em uma máquina de ensaio universal, numa velocidade de 0,5 mm/min. Os resultados mostraram uma superioridade estatisticamente significante (p = 0,025) da porcelana Empress 2 (86,68 Kgf) em relação à porcelana In-Ceram Zircônia (67,87 Kgf), e não foi encontrada correlação estatística entre as medidas das áreas de conexão com os valores máximos de carga. O modo de fratura mostrou que em todos os corpos de prova de Empress 2 e em seis corpos de prova de In-Ceram a fratura ocorreu no sentido oblíquo se estendendo da região onde a carga foi aplicada até a área de conexão. Três corpos de prova de In-Ceram fraturam verticalmente na área de conexão e um corpo de prova fraturou-se verticalmente na região do pôntico sem ocorrer danos à área de conexão. / The aesthetic appeal has influenced the dental materials industries and the researchers to develop materials that present, besides the aesthetics, enough resistance to oclusal forces. Thus, the aim of this research was to compare the compressive fracture strength of IPS Empress 2 and In-Ceram Zirconia of frameworks of three unit resin-bonded fixed partial denture. Forty natural extracted teeth (twenty maxilar first premolars and twenty molars) were selected and received inlay preparations, according to the ceramic manufacturer´s directions. The frameworks were made by two experimented technicians, and cemented with Variolink II. The axial compressive load was conducted in a universal testing machine at a cross-head speed of 0,5 mm/min. The results showed a statistical significant superiority (p = 0,025) of the Empress 2 (105,30 Kgf) regarding to In-Ceram (101,68 Kgf). It wasn't found statistical correlation between measures of the connection areas and maximum values. All Empress 2 and six In-Ceram frameworks showed a similar mode of fracture extending obliquely from the region where the load was applied until the connection area. Three In-Ceram framewoks fractured vertically at the connection area and one was fractured vertically at the pontic area.
22

Análise do estresse gerado em componentes de prótese fixa implanto-suportada através do uso de extensômetros

Jacques, Letícia Borges 05 May 2000 (has links)
O êxito clínico dos implantes osseointegrados é amplamente determi nado, pela maneira como o estresse mecânico é transferido do implante, ao tecido ósseo circundante, sem gerar forças de grande magnitude, o que poderia colocar em risco a longevidade do próprio implante e da restauração protética. Inúmeros aprimoramentos técnicos, assim como desenhos e ligas metálicas alternativas para a confecção de infra-estruturas, têm sido propostos para melhorar os procedimentos protéticos. O objetivo deste trabalho foi verificar a distribuição de estresse em componentes de prótese fixa implanto-suportada, através do uso de extensômetros, em função de duas ligas metálicas. Corpos de prova simulando infra-estruturas para uma situação de prótese total fixa mandibular, foram confeccionados em liga de cobalto -cromo e paládio-prata e posicionados sobre um modelo-mestre. Uma carga estática vertical de 100N foi aplicada na extremidade livre, a uma distância de 10, 15 e 20mm para distal do centro do intermediário terminal. Os resultados demonstraram que em grandes extensões de cantilever, a liga de cobalto-cromo apresentou um padrão de distribuição de forças semelhante à liga de paládio-prata com cantilever curto. Independente do local de aplicação da força e da liga utilizada na confecção das infra-estruturas, o intermediário mais próximo do ponto de aplicação da carga foi o que registrou a maior deformação específica. O emprego de uma liga de cobalto-cromo na confecção de infra-estruturas para prótese sobre implantes pode permitir braços de cantilever mais extensos. / The clinical success of osseointegrated implants are largely influenced by the manner mechanical stresses are transfered from implant to surrounding bone, without generating forces of a magnitude that would jeopardize the longevity of implant and prosthesis. A variety of technical improvements, as well as alternative framework designs and alloys have been reported to improve prosthetic procedures. The aim of this study was to analyse stress distribution on components of a fixed implant-supported prostheses, fabricated with two metal alloys. The samples simulated a typical mandibular fixed complete -arch framework and were fabricated on cobalt-chromium alloy and palladium-silver alloy and positioned on a master-cast. A vertical estatic load of 100N was applied on the cantilever arm at a distance of 10, 15 and 20mm from the center of distal abutment. Strain gauges were positioned on the mesial and distal aspects of each abutment to capture deformation.The results demonstrated that for large cantilever extensions, the cobalt-chromium alloy presented a pattern of force distribution similar to that observed with palladium-silver alloy with short cantilever. Irrespective of the point of load application and the metal alloy used in the framework construction, the abutment closer to the point of load application registered the highest especific deformation. Using a cobalt-chromium alloy may allow longer cantilever arms.
23

Imunização de carteiras de renda fixa via um modelo paramétrico exponencial

Lund, Bruno Pereira 12 1900 (has links)
Made available in DSpace on 2008-05-15T19:16:31Z (GMT). No. of bitstreams: 1 063202004_Dissertacao_Bruno_Lund.pdf: 756653 bytes, checksum: dc81c7cf292e2c8f3512a977939d8a73 (MD5) Previous issue date: 2007-12 / Submitted by Carlos Oliveira (carlos.oliveira@fgv.br) on 2008-05-15T19:16:31Z No. of bitstreams: 1 063202004_Dissertacao_Bruno_Lund.pdf: 756653 bytes, checksum: dc81c7cf292e2c8f3512a977939d8a73 (MD5) / Litterman e Scheinkman (1991) mostram que mesmo uma carteira de renda xa duration imunizada (neutra) pode sofrer grandes perdas e, portanto, propõem fazer hedge de carteiras utilizando a análise de componentes principais. O problema é que tal abordagem só é possível quando as taxas de juros são observáveis. Assim, quando as taxas de juros não são observáveis, como é o caso da maior parte dos mercados de dívida externa e interna de diversos países emergentes, o método não é diretamente aplicável. O presente trabalho propõe uma abordagem alternativa: hedge baseado nos fatores de um modelo paramétrico de estrutura a termo. A imunização feita utilizando esta abordagem não só se mostra simples e e ciente, mas também, equivalente ao procedimento de imunização proposto por Litterman e Scheinkman quando as taxas são observáveis. Exemplos do método para operações de hedge e alavancagem no mercado de títulos da dívida pública brasileira indexada a in ação são apresentados. O trabalho ainda discute como montar e apreçar carteiras que replicam fatores de risco, o que permite extrair alguma informação sobre a expectativa dos agentes acerca do comportamento futuro da curva de juros. Por m, faz uma comparação da expectativa de in ação futura implícita nos preços dos títulos públicos da dívida interna brasileira (LTN/NTN-F e NT
24

Avaliação do SISDA (Sistema de Suporte à Decisão Agrícola) para manejo de irrigação na região de Araçuaí-MG / Evaluation of the Agricultural Decision Support System SISDA, for irrigation schedduling in the Jequitinhonha Valley Brazil

Borges, Henrique Queiroz 13 August 1999 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2016-05-24T10:50:00Z No. of bitstreams: 1 texto completo.pdf: 2093846 bytes, checksum: d8d120f1927ed3d3e9a8a73446458465 (MD5) / Made available in DSpace on 2016-05-24T10:50:00Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2093846 bytes, checksum: d8d120f1927ed3d3e9a8a73446458465 (MD5) Previous issue date: 1999-08-13 / Fundação de Amparo à Pesquisa do Estado de Minas Gerais / No período de maio a agosto de 1998, utilizou-se o SISDA (Sistema de Suporte à Decisão Agrícola) para fazer o manejo de irrigação em duas culturas: abacaxi irrigado por aspersão fixa e banana irrigada por microaspersão. O modelo é baseado no balanço de água no solo. Dado as características do sistema de irrigação e as condições iniciais de umidade do solo, o modelo simula a evapotranspiração da cultura, a precipitação efetiva e a umidade atual do solo, determinando a hora de irrigar e quanto de água aplicar, usando dados climáticos. A evapotranspiração de referência foi estimada utilizando-se o método de Penman-Montieth, FAO 1991. Inicialmente avaliaram-se os sistemas de irrigação, determinando-se os parâmetros físico-hídricos do solo e os parâmetros de desempenho correspondentes a uniformidade de aplicação de água e eficiências de irrigação e de bombeamento. No cálculo da evapotranspiração utilizou-se o método Penman-Monteith FAO 1991. Os valores de evaporação do Tanque Classe A foram medidos para determinação do coeficiente de tanque para a região. A umidade do solo foi determinada semanalmente, utilizando o método- padrão de estufa, e os resultados foram comparados com os valores obtidos da simulação com o SISDA. Analisou-se o desempenho do SISDA, considerando o manejo durante todo o experimento sem corrigir os valores de umidade simulada e corrigindo-os a cada duas semanas e a cada quatro semanas. Nas avaliações, as irrigações foram realizadas no momento certo nas duas áreas; entretanto, as lâminas aplicadas foram insuficientes para elevar o teor de umidade à capacidade de campo, nos dois sistemas. Os valores dos coeficientes de uniformidade de Christiansen encontrados foram inferiores a 75% para a aspersão convencional e superiores a 90% para a microaspersão, e os coeficientes de uniformidade de distribuição foram inferiores a 65% para a aspersão convencional e superiores a 88% para a microaspersão. A perda por percolação profunda foi pequena nas duas áreas avaliadas, uma vez que as lâminas aplicadas foram menores que a necessária. As eficiências potenciais de aplicação foram de 81 e 98%, e as perdas por evaporação e arrastamento pelo vento foram de 18,9 e 1,6% para a aspersão convencional e a microaspersão, respectivamente. As eficiências de condução foram de 100%, nos dois sistemas, em virtude da não-constatação de nenhum vazamento. O cálculo da eficiência, baseado na metodologia proposta por KELLER e BLIESNER (1990), superestimou os valores da eficiência potencial de aplicação e subestimou a perda por evaporação e arrastamento pelo vento. A eficiência de aplicação foi de 76,8% para a aspersão convencional e 90,7% para a microaspersão. A eficiência da bomba do sistema de aspersão convencional foi de 47,8%, e a do sistema de microaspersão, de 42,7%. Os valores de ETo para o ano de 1998 foram maiores que os referentes à série histórica. O valor de kt foi de 0,69 para o Tanque Classe A instalado em superfície com bordadura de solo nu, velocidade do vento fraca e umidade relativa média alta. Os valores de umidade do solo simulados pelo SISDA foram iguais ou inferiores aos valores observados na área irrigada por aspersão convencional, enquanto na irrigada por microaspersão eles foram iguais ou superiores. O SISDA superestimou a evapotranspiração da cultura do abacaxi e subestimou a da banana. Pode-se utilizar o SISDA com segurança para manejo de irrigação na região de Araçuaí- MG. / From May to August of 1998 the Agricultural Decision Support System SISDA was used for irrigation schedduling a pineapple sprinkler irrigation system and a banana microsprinkler irrigation system in the Jequitinhonha Valley. The model is based on the soil water volume balance. Given the irrigation system characteristics and the soil moisture initial conditions the model simulates the crop evapotranspiration, the effective precipitation and the actual soil moisture, and shows the farmer when to irrigate and how much water to apply, using the climate data as input. The reference evapotranspiration was estimated using the Penman-Montieth FAO 1991 method. The soil moisture was determined weekly using the standard method and the results were compared with those simulated by the model. The soil moisture simulated by the model can be corrected any time. Therefore, the performance of the model was analyzed considering the irrigation management during all the experiment without any correction in the soil moisture simulated, correcting it every four weeks and every two weeks. Initially, the soils characteristics were determined and the irrigation systems were evaluated, for two irrigation events. The irrigation were made in the right moment, but irrigation depths were not enough to bring the soil moisture to field c bellow 75% por the sprinkler irrigation system and above 90% for the microsprinkler irrigation system. The distribution uniformities were bellow 65% and above 88% for the sprinkler and the microsprinkler irrigation systems, respectively. The deep percolation losses were negligible for both systems, due to the low irrigation depth applied. The evaporation and wind drift losses were 18.9% and 1.6% for the sprinkler and the microsprinkler systems, respectively. The Keller and Bliesner methodology underestimated the evaporation and wind drift losses. The application efficiency was 76.8% for the sprinkler irrigation system and 90.7% for microsprinkler. The pump efficiency was 47.8% in sprinkler irrigation system and 42.7% in the microsprinkler. The reference evapotranspiration values for 1998 were higher than the historical ones. The coefficient for a class A pan installed in a bare soil area was approximately 0.69 during the experiment for a low wind speed and high relative humidity. The soil moisture values simulated by the model were equal or lower than the real values for the sprinkler irrigation system and equal or higher than the real values for the microsprinkler system. The soil moisture during all the experiment was kept between the field capacity and the minimum values recommended for the crops studied, even when no actualization was made in the soil moisture during the experiment, showing that the model can be recommended for irrigation management in the Jequitinhonha Valley, Brazil. / Não foram encontrados o CPF e o currículo lattes do autor.
25

Avaliação da resistência à fratura de próteses fixas temporárias reforçadas por uma malha experimental /

Almeida, Carolina Souza. January 2015 (has links)
Orientador: Tarcisio José de Arruda Paes Junior / Banca: Lafayette Nogueira Júnior / Banca: Alfredo Mikail Melo Mesquita / Resumo: O objetivo no projeto foi avaliar a resistência à fratura de próteses fixas temporárias, com ou sem reforço posicionado em diferentes orientações (horizontal ou vertical), antes e após a termociclagem. Foram confeccionadas 72 próteses fixas temporárias de quatro elementos com resina bis-acrílica, divididas em três grandes grupos: sem reforço, com reforço horizontal e com reforço vertical. Cada grupo foi subdividido em dois, submetidos ou não a ciclagem térmica, totalizando seis subgrupos (n = 12). O reforço consiste em uma malha de nylon revestida por sílica (experimental). Os grupos ciclados receberam 1.000 ciclos térmicos. Todos os espécimes foram submetidos ao ensaio de resistência à fratura em uma máquina de ensaio universal (EMIC), com velocidade de 1,0 mm/min. No segundo experimento foi avaliada a influência do reforço em barras com dimensões de 25 X 10,5 X 3,3mm. As barras foram submetidas à termociclagem como descrito acima e ao ensaio de resistência à flexão 3 pontos, com velocidade de 5mm/min, com celular de carga de 10 KN. A análise estatística foi realizada através dos testes de Kruskal-Wallis Dunn (5%) e demonstrou que a incorporação e a disposição da malha influenciaram a resistência à fratura e a resistência à flexão da resina bis-acrílica foi aprimorada após a adição da malha / Abstract: The aim of this study was to evaluate fracture resistance of temporary bridges as the influence of the addition of a modified nylon mesh in a bis-acrylic resin (Structur 2SC, VOCO, Cuxhaven, Germany). To the first step a temporary fixed prosthesis was made and were analyzed the presence or absence of the fiber and your position (horizontal or vertical). Some groups was subjected to thermal cycling of 1,000 to simulate a temporary fixed prosthesis with extended use period. All specimens were subjected to the test of fracture resistance in a universal testing machine (EMIC DL 1000, EMIC, Brazil), with a speed of 1.0 mm / min. For the second experiment, the test specimens was made in bar shaped (25 x 10.5 x 3.3 mm). The bars were analyzed concerning groups containing or not fibers. Some specimens were subjected to thermal cycling 1,000 cycles. All bars were submitted to the flexural strength by three points bending test in a universal testing machine at constant speed 5 mm/min with load cell of 10 kN. Statistical analysis was performed with Kruskal-Wallis and Dunn tests (5%) and demonstrated that the incorporation and arrangement of the mesh influence the fracture toughness and flexural strength of the bis-acrylic resin was improved afte adding the mesh / Mestre
26

Estudo da resistência residual das cerâmicas de dissilicato de lítio submetidas a diferentes protocolos de fadiga / Mechanical behavior study of lithium disilicate ceramic subjected to different cycling protocols

Barcellos, Aline Serrado de Pinho [UNESP] 04 November 2016 (has links)
Submitted by Aline Serrado de Pinho Barcellos null (alinebarcellosodonto@hotmail.com) on 2016-12-18T12:01:55Z No. of bitstreams: 1 dissertaçãoImpressão.pdf: 3771981 bytes, checksum: 5f352cb7c8b67d15d25214beae5fe249 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-12-20T17:14:58Z (GMT) No. of bitstreams: 1 barcellos_asp_me_sjc.pdf: 3771981 bytes, checksum: 5f352cb7c8b67d15d25214beae5fe249 (MD5) / Made available in DSpace on 2016-12-20T17:14:58Z (GMT). No. of bitstreams: 1 barcellos_asp_me_sjc.pdf: 3771981 bytes, checksum: 5f352cb7c8b67d15d25214beae5fe249 (MD5) Previous issue date: 2016-11-04 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do estudo foi avaliar o comportamento mecânico de uma cerâmica, à base de dissilicato de lítio, em ensaio de flexão com as extremidades fixas. Este estudo particular tem similaridade com caso real de aplicação de prótese em pacientes, o que melhora a avaliação do material quando comparado a ensaios convecionais como o ensaio de flexão em três pontos, com viga simplesmente apoiada. Para isso os corpos de prova foram submetidos à três tipos de envelhecimento: ciclagem mecânica, ciclagem termomecânica, ambas de acordo com os protocolos utilizados na literatura, e ciclagem intrabucal. A ciclagem intrabucal foi realizada por meio da utilização de um dispositivo intrabucal semelhante a uma placa oclusal, na qual foram instalados os corpos de prova, por meio de um dispositivo metálico próprio. Estas placas foram utilizadas em dez voluntários por oito horas, durante o período noturno. As amostras foram posteriormente submetidas ao ensaio mecânico de flexão de três pontos com as extremidades engastadas, para avaliação da resistência residual. Os resultados de resistência residual foram submetidos à análise estatística descritiva (média e desvio padrão) e inferencial, mediante o teste paramétrico de análise de variância (ANOVA) um fator e o teste de Tukey ( = 0,05). As amostras representativas de cada grupo foram observadas em microscópio eletrônico de varredura para análise fractográfica. O tipo de ciclagem influenciou no comportamento mecânico da cerâmica, apresentando significância estatística (p = 0,000) e o grupo de ciclagem intrabucal mostrou a menor resistência à flexão. A origem da fratura foi na zona de tração, porém observou-se uma origem secundária localizada em zona de torção. Pode-se concluir que os tipos de ciclagens influenciaram no comportamento mecânico da cerâmica de dissilicato de lítio. As ciclagens mecânica, termomecânica e intrabucal reduziram a resistência à flexão do material. A ciclagem intrabucal foi a que mais reduziu a resistência residual em flexão deste tipo de cerâmica. / This study aimed to evaluate the behavior of lithium disilicate ceramic in similar condition to a partial fixed prosthesis of three elements by subjecting to three types of aging (n=10): mechanical cycling, thermomechanical cycling, both according to the protocols used in the literature, and intraoral cycling. The intraoral cycling was accomplished by using an intraoral device, which is similar to an occlusal splint. They were installed with the samples (CP) by means of a metallic device that was fixed in balanced contact condition with the remainder of the occlusal surface of the plate. These plates were used in ten volunteers for eight hours during the evening. After fatigue, the samples were subjected to three-point bending tests with clamped ends to evaluate the residual strength. The residual strength results were submitted to descriptive statistics (mean and standard deviation) and inferential by the parametric analysis of variance (ANOVA), with one factor and Tukey test ( = 0.05). In addition, representative samples of each group were observed in a scanning electron microscope (SEM) for fractographic analysis. The cycling condition influenced the mechanical behavior of ceramic with statistical significance of (p = 0,000), and the intraoral cycling group showed the lowest residual flexural strength. In fractographic analysis, they showed that the origin of fracture was in the tensile zone, but there was a secondary fracture origin represented by a twisted zone. Therefore, all types of cycling influenced the flexural strength of the material.
27

Influência do método de aquecimento de revestimentos fosfatados sobre sua resistência à compressão e sobre a rugosidade de superfície e estabilidade dimensional de ligas de Ni-Cr e Ni-Cr-Ti /

Zequetto, Michele Marques. January 2009 (has links)
Orientador: Eulália Maria Martins Silva / Banca: Maria Cristina Rosifini Alves Rezende / Banca: Paulo Renato Junqueira Zuim / Banca: Renata Garcia Fonseca / Banca: Maria da Gloria Chiarello de Mattos / Resumo: No processo de fundição pela cera perdida, os materiais envolvidos podem apresentar interações entre si e o de tempo despendido para se obter as estruturas metálicas é oneroso. Assim, o objetivo deste trabalho foi avaliar a influência da propriedade física de resistência à compressão de revestimentos fosfatados indicados para altas temperaturas de fundição, utilizando os métodos de aquecimento convencional (MAC) e rápido (MAR), e analisar a rugosidade de superfície e a alteração dimensional do produto final da fundição (a peça metálica) obtido com as ligas metálicas Ni-Cr (Verabond II) e Ni-Cr-Ti (Fit Cast Titanium). Os revestimentos estudados Castorit Super C, Castorit All Speed, Heat Shock e Micro Fine 1700 foram vazados em uma matriz de silicone que permitiu obter amostras com formato cilíndrico (n=200), medindo 10mm de diâmetro e 20mm de comprimento. A resistência (MPa) deles foi determinada à temperatura ambiente (resistência fria) após 15, 30 e 60 minutos de manipulação, e também imediatamente após serem submetidos aos métodos de aquecimento MAC e MAR (resistência de queima), por meio de uma máquina de ensaio universal, em velocidade de 0,05mm/min e carga de 150kgf. Após inclusão, aplicação dos métodos de aquecimento e fundição às amostras (n=120) para rugosidade de superfície (Ra-μm), foram avaliadas por um rugosímetro Mitutoyo Surftest SJ-401 com cut-off de 0,8mm e três repetições em cada amostra. A alteração dimensional foi determinada pela diferença entre os valores dimensionais da cera e da peça fundida (n=60) utilizando-se o software AutoCad2008. Os valores médios obtidos foram submetidos à análise de variância (ANOVA) e ao teste de Tukey (p<0,05), apresentando os valores de resistência à compressão diferentes entre os revestimentos (Heat Shock os valores maiores) e entre os tempos de mensuração em relação... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In the lost wax casting procedure, the involved materials can present interactions among them and the time used to obtain the metallic structures is onerous. Thus, the purpose of this study was to evaluate the influence of the compressive strength physical property of phosphate-bonded investment materials indicated for high casting temperatures, utilizing conventional heating (CHM) and quick heating methods (QHM), and analyze the surface roughness and the dimensional accuracy of the final casting product (the metallic piece) obtained from Ni-Cr (Verabond II) and Ni-Cr-Ti (Fit Cast Titanium) metallic alloys. Castorit Super C, Castorit All Speed, Heat Shock and Micro Fine 1700 investment materials were poured into a silicone matrix in order to obtain cylindrical samples (n=200), measuring 10mm in diameter and 20mm in length. Their strength (MPa) was determined at room temperature (green strength) after 15, 30 and 60 minutes of manipulation, and also immediately after being submitted to the CHM and QHM heating methods (fired strength), by means of an universal testing machine at 0,05mm/min speed and 150kgf load. After investing, applying the heating methods and casting the samples (n=120) for surface roughness (Ra), the samples were evaluated with a Mitutoyo Surftest SJ-400 profilometer with 0,8mm cut-off, three times in each sample. The dimensional accuracy was determined by the difference among the dimensional values of the wax and of the metallic piece (n=60) through the software AutoCad2008. The mean values obtained were submitted to ANOVA and Tukey tests (p <0.05), and the results showed that the values of compressive strength were different among the investment materials (Heat Shock presenting the highest values) and among the analysis times with a direct relation of time and strength increase, but there was no difference between CHM and QHM. Moreover, it was observed no differences... (Complete abstract click electronic access below) / Doutor
28

Obtenção tecnológica de comprimido revestido dose-fixa-combinada à base de Zidovudina, Lamivudina e Efavirenz

Emanuelle Ramos da Silva, Keyla 31 January 2009 (has links)
Made available in DSpace on 2014-06-12T16:30:24Z (GMT). No. of bitstreams: 2 arquivo2769_1.pdf: 1476476 bytes, checksum: f489c0dfdb69736e0a70154f1cfcb5c5 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2009 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O acesso de pacientes infectados à terapia anti-retroviral é uma prioridade da saúde pública mundial em países em desenvolvimento. A grande quantidade de fármacos já disponibilizados para o tratamento da AIDS, viabiliza novas associações terapêuticas, o que proporciona uma maior adesão ao tratamento, diminuindo o índice de mortalidade dos pacientes infectados. Para tal finalidade tem-se desenvolvido anti-retrovirais em dose-fixa-combinada. Esse tipo de associação proporciona uma maior adesão ao tratamento quando comparada à administração dos medicamentos em separado. Este trabalho teve como objetivos o estudo de estabilidade dos fármacos zidovudina, lamivudina e efavirenz, em meios ácido e básico, a caracterização físico-química destas drogas, assim como o desenvolvimento da forma farmacêutica como comprimido revestido dose-fixa-combinada. Desenvolveu-se e validou-se também um método analítico de doseamento, por cromatografia líquida de alta eficiência (CLAE), capaz de quantificar os três fármacos presentes na forma farmacêutica simultaneamente. As matérias-primas dos três fármacos apresentaram qualidade adequada e o método analítico desenvolvido e validado apresentou resultados satisfatórios para todos os quesitos avaliados. Diante dos resultados alcançados, pode-se garantir a obtenção da forma farmacêutica comprimido revestido dose-fixa-combinada à base de zidovudina, lamivudina e efavirenz com qualidade e confiabilidade comprovadas, requisitos fundamentais no desenvolvimento de um medicamento segundo as Boas Práticas de Fabricação e Controle (BPFC), preconizados pelo órgão regulatório (ANVISA-MS)
29

Desenvolvimento de comprimidos revestidosdose-fixa-combinada estavudina + lamivudina + nevirapina para tratamento da AIDS

Renata Queiroz de Farias, Silvia January 2006 (has links)
Made available in DSpace on 2014-06-12T16:32:44Z (GMT). No. of bitstreams: 2 arquivo6461_1.pdf: 1514992 bytes, checksum: 371b23e18f6865a5dc4d02abbedf5f97 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2006 / É prioridade de saúde pública mundial a introdução de novos agentes anti-retrovirais no mercado, e no Brasil, o Ministério da Saúde (MS), de acordo com a lei n° 9.313/96, tem garantido distribuição gratuita de medicamentos a todos os portadores do HIV e doentes de AIDS , assegurando tratamento anti-retroviral adequado para cada estágio evolutivo da doença. Atualmente, são utilizadas quatro classes terapêuticas com esta finalidade: inibidores de transcriptase reversa análogos de nucleosideo, inibidores de transcriptase reversa não análogos de nucleosídeo, inibidores de protease e inibidores de fusão. Por se tratar de uma doença com alto nível de replicação, o vírus da imunodeficiência humana (HIV) contribui para a ocorrência de mutações e, conseqüentemente, resistência aos medicamentos existentes. O tratamento anti-retroviral padrão sempre deve incluir três fármacos, podendo ser utilizados separadamente ou na forma de dose-fixa-combinada, sendo esta última, a melhor opção, uma vez que este tipo de esquema resulta em melhor adesão e conseqüentemente, diminuição do índice de falhas na terapia. Este trabalho teve como objetivo o desenvolvimento de comprimido revestido dose-fixa-combinada, à base de estavudina 40 mg, lamivudina 150 mg e nevirapina 200 mg em uma única forma farmacêutica, baseado em uma planificação quali-quantitativa dos excipientes, e sua obtenção através do método por via úmida. Para o processo de revestimento foram testados dois sistemas de dispersão com solvente aquoso. Como etapa inicial, realizou-se a caracterização dos insumos ativos. Também, foi realizado o desenvolvimento da metodologia analítica para doseamento do produto acabado por cromatografia líquida de alta eficiência (CLAE). Os comprimidos revestidos desenvolvidos apresentaram qualidade aceitável do ponto de vista farmacotécnico, sendo a próxima etapa a transposição de escala e o estudo de estabilidade, com a finalidade de garantir a eficácia e a qualidade do medicamento desenvolvido. A produção desta associação é mais um passo para o tratamento da AIDS, visto que esta proposta terapêutica é inédita no país e garantirá uma maior eficácia aos tratamentos já utilizados, principalmente para países em desenvolvimento na América, Ásia e África
30

Influencia do remanescente dental do termino gengival e da retenção intra-radicular na resistencia a fratura de restaurações proteicas

Carlini Junior, Bruno 23 October 2001 (has links)
Orientador : Luis Alexandre Maffei Sartini Paulillo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T23:36:23Z (GMT). No. of bitstreams: 1 CarliniJunior_Bruno_D.pdf: 4989185 bytes, checksum: 746f907f11f3e05fc033d327df974b66 (MD5) Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi avaliar o padrão e a resistência à fratura de dentes bovinos tratados endodonticamente e restaurados através de coroas unitárias metálicas nas seguintes condições experimentais: presença ou não de remanescente dental coronário com 2 mm de comprimento; término gengival em ombro-biselado, chanfrado e ombro; e dois métodos de retenção intra-coronária, núcleo metálico fundido e pino metálico pré-fabricado paralelo rosqueado. Cento e vinte raízes bovinas receberem tratamento endodôntico e foram fixadas em cilindros de resina acrílica por meio de ligamento periodontal artificial para serem submetidas ao carregamento tangencial de compressão a 0,5 mm/min e 135°, até ocorrer a fratura. Os resultados (ANOVAI DMMQ a=0,05) demonstraram que houve diferença estatística para as condições término gengival (ombro biselado >=chanfrado> ombro), retenção intra-radicular (pino pré-fabricado> núcleo metálico fundido) e presença de remanescente coronário (com remanescente> sem remanescente); bem como para as interações remanescente x pino e remanescente x término, em que os grupos com remanescente apresentaram valores superiores aos grupos sem remanescente, com diferença estatística significativa. Foi possível concluir que a resistência mecânica de raízes reconstruídas proteticamente tem relação com a quantidade de remanescente coronário, método de retenção intra-radicular e formato de término gengival / Abstract: The aim of this study was to evaluate both the pattern and the fracture strength of bovine teeth endodontically treated through metallic unitary crowns under the following experimental conditions: presence or not of dental coronal structure with 2mm in length; cervical beveled shoulder, chamfered and shoulder; and two methods of intraradicular retention, cast post and core and parallel threaded prefabricated metallic posts. Endodontically treated 120 bovine dental roots were fixed to acrylic resin cylinders by means of artificial periodontal ligament, and then submitted to the compressive strength, at 1350 and 0,5 mm/min, until reaching the fracture. The results (ANOVA/ DMMQ a=0,05) showed statistical significance for the following conditions: cervical prosthetic design (beveled sholder >=chanfer > sholder), intraradicular retention (prefabricated posts > cast post and core) and coronal structure (with 2 mm of coronal structure > without dental structure); It was possible to conclude that the mechanical resistance of the restored roots is correlated with the amount of coronary dental structure, the intra-radicular retention method, and the prosthetic gingival shape / Doutorado / Dentística / Doutor em Clínica Odontológica

Page generated in 0.0495 seconds