• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 63
  • 1
  • 1
  • Tagged with
  • 67
  • 49
  • 15
  • 14
  • 11
  • 11
  • 11
  • 9
  • 9
  • 9
  • 8
  • 7
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Desenvolvimento de metodologias indicativas de estabilidade para medicamentos utilizados como diuréticos / Development of stability-indicating assay for diuretics drugs.

Souza, Aline de 11 December 2015 (has links)
Os diuréticos aumentam o fluxo urinário e a excreção de sódio e são utilizados para ajustar o volume e/ou a composição dos líquidos corporais em uma variedade de situações clínicas. A furosemida é um agente diurético potente que induz uma poderosa diurese. É utilizada no tratamento de edema associado com o coração e doenças renais. Nesta pesquisa objetivou-se desenvolver métodos indicativos de estabilidade para a furosemida, por eletroforese capilar em solução livre (FSCE) e cromatografia liquida de alta eficiência (CLAE). O método por FSCE utilizou um capilar de sílica fundida com comprimento total de 30,2 cm x 50,0 µm d.i. O tampão utilizado foi tetraborato de sódio 2,0 mmol L-1 e 10% de metanol, injeção hidrodinâmica 0,5 psi/5s, tensão aplicada +25 kV, detecção em 273 nm e temperatura a 25ºC. O tempo de migração da furosemida foi de 1,8 minutos. O método obteve boa linearidade no intervalo de 70,0 a 130,0 µg.mL-1 com coeficiente de correlação maior de 0,99. Os limites de detecção e de quantificação foram 6,2 µg.mL-1 e 20,6 µg.mL-1, respectivamente. A precisão do sistema foi inferior a 2,0%. A repetibilidade e precisão intermediária foram inferiores a 5,0%. A recuperação média foi de 102,1 %. No teste de especificidade, foram detectados três potenciais produtos de degradação com os seguintes tempos de retenção 1,3 2,0 e 2,2 min. O método por CLAE utilizou uma coluna Shim-pack CLC-ODS(M)® (250mm x4.6mm, 5µm). A fase móvel era constituída de acetonitrila:água (50:50) com 0,1% de ácido fórmico. O fluxo foi de 1.0 mL min-1 e detecção em 273 nm e temperatura a 30 ± 1 ºC. O método apresentou boa linearidade nas concentrações entre 7,0 e 13 µg.mL-1; com coeficiente de correlação maior de 0,99. E tempo de retenção para furosemida foi de 4,9 minutos. Os limites de detecção e de quantificação foram 0,6 µg.mL-1 e 1,9 µg.mL-1, respectivamente. A precisão do sistema foi inferior a 1,0%. A repetibilidade e precisão intermediária foram inferiores a 3,0%. A recuperação média foi de 105,1 %. No teste de especificidade, foram detectados três potenciais produtos de degradação com os seguintes tempos de retenção 2,4, 3,1 e 3,8 min. / Diuretics increase urine flow and sodium excretion and are used to adjust volume and / or composition of body fluids in a variety of clinical situations. Furosemide is a potent diuretic agent that induces a strong diuresis. It is used in the treatment of edema associated with heart and kidney disease. This research aimed to develop stability indicative methods for furosemide, by capillary electrophoresis in free solution (FSCE) and high-performance liquid chromatography (HPLC). The method FSCE used a fused silica capillary with a total length of 30.2 cm x 50.0 um di The buffer used was sodium tetraborate 2.0 mmol L-1 and 10% methanol, hydrodynamic injection 0.5 psi / 5s, +25 kV applied voltage, detection at 273 nm and 25 °C. The furosemide migration time was 1.8 minutes. The method achieved good linearity in the range of 70.0 to 130.0 µg.mL-1 with correlation coefficient higher of 0.99. The limits of detection and quantification were 6.2 and 20.6 µg.mL-1 µg.mL-1, respectively. The system accuracy was less than 2.0%. The repeatability and intermediate precision were less than 5.0%. The average recovery was 102.1%. The specificity test detected three potential degradation products with the following retention times 1.3, 2.0 and 2.2 min. The HPLC method used a Shim-pack CLC-ODS (M)® column (250mm x 4.6mm, 5µm). The mobile phase consisted of acetonitrile: water (50:50) with 0.1% formic acid. The flow rate was 1.0 mL min-1, detection at 273 nm and temperature at 30 ± 1°C. The method showed good linearity in concentrations between 7.0 and 13.0 µg.mL-1; with correlation coefficient higher of 0.99. Retention time for furosemide was 4.9 minutes. The limits of detection and quantification were 0.6 µg.mL-1 and 1.9 µg.mL-1, respectively. The system accuracy was less than 1.0%. The repeatability and intermediate precision were less than 3.0%. The average recovery was 105.1%. The specificity test detected three potential degradation products of the following retention times of 2.4, 3.1 and 3.8 min.
52

Desenvolvimento de metodologias indicativas de estabilidade para medicamentos que atuam no diabetes mellitus tipo II / Development of stability indicating methods for drugs that are used in diabetes mellitus 2

Galdos, Angel Arturo Gaona 23 November 2012 (has links)
O diabetes mellitus (DM) é uma síndrome na qual o metabolismo de hidratos de carbono, gorduras e proteínas está alterado, por falta de secreção de insulina ou por diminuição da sensibilidade tissular a este hormônio. O DM pode ser do tipo I, também denominado diabetes mellitus insulinodependente (DMID), caracterizado pela falta de secreção da insulina, e do tipo II, também denominado diabetes mellitus não insulinodependente (DMNID), caracterizado pela menor sensibilidade dos tecidos efetores às ações metabólicas da insulina. Embora ainda não haja cura definitiva, há vários tratamentos disponíveis que proporcionam qualidade de vida para o paciente portador, como a administração de hipoglicemiantes orais. Nesta pesquisa, objetivou-se desenvolver métodos indicativos de estabilidade para a glibenclamida e o cloridrato de metformina. Assim, foram desenvolvidos métodos de rastreamento ortogonais utilizando a cromatografia líquida de alta eficiência (HPLC) e a eletroforese capilar (CE), metodologias que foram desafiadas com os estudos da degradação forçada. Realizou-se, também, a identificação do principal produto de degradação da glibenclamida utilizando a cromatografia líquida acoplada à espectrometria de massa (LC-MS). O método por HPLC teve o melhor desempenho no monitoramento dos produtos de degradação da glibenclamida, apresentando boa linearidade nas concentrações entre 0,210 e 0,360 mg/mL; com coeficiente de correlação maior de 0,99. A precisão calculada como desvio padrão relativo (DPR) foi menor de 3%, exatidão do método comprovada mediante teste de recuperação, obtendo-se valores de 100±3,0%. No teste de especificidade, foram detectados três potenciais produtos de degradação, com os seguintes tempos de retenção relativos (TRR) de 0,33; 0,46 e 0,83. O método CZE teve o melhor desempenho no monitoramento dos produtos de degradação do cloridrato de metformina, apresentando boa linearidade nas concentrações entre 0,210 e 0,360 mg/mL, com coeficiente de correlação maior de 0,99. A precisão, calculada como DPR, foi menor do que 5%, exatidão do método comprovada mediante o teste de recuperação, obtendo-se valores de 100±3,5%. No teste de especificidade, foram detectados cinco potenciais produtos de degradação com os seguintes TRRs de 0,90; 1,14; 1,35; 1,45 e 1,56. / Diabetes mellitus (DM) is a syndrome which alters the metabolism of carbohydrates, fats and proteins by lack of insulin secretion or a decrease in tissue sensitivity to insulin. Type 1 DM is also known as insulin-dependent diabetes mellitus is characterized by lack of insulin secretion. The second type of diabetes known as Type II, also called non-insulin dependent, is characterized by the reduced sensitivity of target tissues to the metabolic actions of insulin. Although there is no definitive cure, there are several treatments available that provide quality of life for the patient how treatment with oral hypoglycemic agents. This study had as objective to developed stability-indicating methods for glibenclamide and metformin hydrochloride. Thus, the techniques used in this study involved high performance liquid chromatography (HPLC) and capillary electrophoresis (CE), and both were challenged with forced degradation studies. The identification of degradation products of glibenclamide was also performed, utilizing the mass spectrometry (MS) technique. However, the HPLC technique had the best performance for monitoring the degradation products of glibenclamide, which showed a good linearity in concentrations between 0.210 - 0.360 mg/ml, with a correlation coefficient greater than 0.99. The precision was calculated as a relative standard deviation (RSD) which was less than 3%; the accuracy of the method calculated as the percent recovery was obtained with the following values: 100 ± 3.0%. On the specificity were detected three potential products of degradation utilizing forced degradation, with the following relative retention times (RRT) 0.33, 0.46 and 0.83. The CZE method had the best performance to monitoring the degradation products of metformin hydrochloride, which showed good linearity of concentrations between 0.210 and 0.360 mg/ml, with a correlation coefficient greater than 0.99. The intra-day and inter-day precision calculated as DPR was less than 5%, and an accuracy of this method was achieved using the values of 100 ± 3.5%. In the specificity were five potential degradation products were detected with the following TRRS: 0.90, 1.14, 1.35, 1.45 and 1.56.
53

Desenvolvimento de metodologias indicativas de estabilidade para medicamentos que atuam no diabetes mellitus tipo II / Development of stability indicating methods for drugs that are used in diabetes mellitus 2

Angel Arturo Gaona Galdos 23 November 2012 (has links)
O diabetes mellitus (DM) é uma síndrome na qual o metabolismo de hidratos de carbono, gorduras e proteínas está alterado, por falta de secreção de insulina ou por diminuição da sensibilidade tissular a este hormônio. O DM pode ser do tipo I, também denominado diabetes mellitus insulinodependente (DMID), caracterizado pela falta de secreção da insulina, e do tipo II, também denominado diabetes mellitus não insulinodependente (DMNID), caracterizado pela menor sensibilidade dos tecidos efetores às ações metabólicas da insulina. Embora ainda não haja cura definitiva, há vários tratamentos disponíveis que proporcionam qualidade de vida para o paciente portador, como a administração de hipoglicemiantes orais. Nesta pesquisa, objetivou-se desenvolver métodos indicativos de estabilidade para a glibenclamida e o cloridrato de metformina. Assim, foram desenvolvidos métodos de rastreamento ortogonais utilizando a cromatografia líquida de alta eficiência (HPLC) e a eletroforese capilar (CE), metodologias que foram desafiadas com os estudos da degradação forçada. Realizou-se, também, a identificação do principal produto de degradação da glibenclamida utilizando a cromatografia líquida acoplada à espectrometria de massa (LC-MS). O método por HPLC teve o melhor desempenho no monitoramento dos produtos de degradação da glibenclamida, apresentando boa linearidade nas concentrações entre 0,210 e 0,360 mg/mL; com coeficiente de correlação maior de 0,99. A precisão calculada como desvio padrão relativo (DPR) foi menor de 3%, exatidão do método comprovada mediante teste de recuperação, obtendo-se valores de 100±3,0%. No teste de especificidade, foram detectados três potenciais produtos de degradação, com os seguintes tempos de retenção relativos (TRR) de 0,33; 0,46 e 0,83. O método CZE teve o melhor desempenho no monitoramento dos produtos de degradação do cloridrato de metformina, apresentando boa linearidade nas concentrações entre 0,210 e 0,360 mg/mL, com coeficiente de correlação maior de 0,99. A precisão, calculada como DPR, foi menor do que 5%, exatidão do método comprovada mediante o teste de recuperação, obtendo-se valores de 100±3,5%. No teste de especificidade, foram detectados cinco potenciais produtos de degradação com os seguintes TRRs de 0,90; 1,14; 1,35; 1,45 e 1,56. / Diabetes mellitus (DM) is a syndrome which alters the metabolism of carbohydrates, fats and proteins by lack of insulin secretion or a decrease in tissue sensitivity to insulin. Type 1 DM is also known as insulin-dependent diabetes mellitus is characterized by lack of insulin secretion. The second type of diabetes known as Type II, also called non-insulin dependent, is characterized by the reduced sensitivity of target tissues to the metabolic actions of insulin. Although there is no definitive cure, there are several treatments available that provide quality of life for the patient how treatment with oral hypoglycemic agents. This study had as objective to developed stability-indicating methods for glibenclamide and metformin hydrochloride. Thus, the techniques used in this study involved high performance liquid chromatography (HPLC) and capillary electrophoresis (CE), and both were challenged with forced degradation studies. The identification of degradation products of glibenclamide was also performed, utilizing the mass spectrometry (MS) technique. However, the HPLC technique had the best performance for monitoring the degradation products of glibenclamide, which showed a good linearity in concentrations between 0.210 - 0.360 mg/ml, with a correlation coefficient greater than 0.99. The precision was calculated as a relative standard deviation (RSD) which was less than 3%; the accuracy of the method calculated as the percent recovery was obtained with the following values: 100 ± 3.0%. On the specificity were detected three potential products of degradation utilizing forced degradation, with the following relative retention times (RRT) 0.33, 0.46 and 0.83. The CZE method had the best performance to monitoring the degradation products of metformin hydrochloride, which showed good linearity of concentrations between 0.210 and 0.360 mg/ml, with a correlation coefficient greater than 0.99. The intra-day and inter-day precision calculated as DPR was less than 5%, and an accuracy of this method was achieved using the values of 100 ± 3.5%. In the specificity were five potential degradation products were detected with the following TRRS: 0.90, 1.14, 1.35, 1.45 and 1.56.
54

Desenvolvimento de metodologias indicativas de estabilidade para medicamentos utilizados como diuréticos / Development of stability-indicating assay for diuretics drugs.

Aline de Souza 11 December 2015 (has links)
Os diuréticos aumentam o fluxo urinário e a excreção de sódio e são utilizados para ajustar o volume e/ou a composição dos líquidos corporais em uma variedade de situações clínicas. A furosemida é um agente diurético potente que induz uma poderosa diurese. É utilizada no tratamento de edema associado com o coração e doenças renais. Nesta pesquisa objetivou-se desenvolver métodos indicativos de estabilidade para a furosemida, por eletroforese capilar em solução livre (FSCE) e cromatografia liquida de alta eficiência (CLAE). O método por FSCE utilizou um capilar de sílica fundida com comprimento total de 30,2 cm x 50,0 µm d.i. O tampão utilizado foi tetraborato de sódio 2,0 mmol L-1 e 10% de metanol, injeção hidrodinâmica 0,5 psi/5s, tensão aplicada +25 kV, detecção em 273 nm e temperatura a 25ºC. O tempo de migração da furosemida foi de 1,8 minutos. O método obteve boa linearidade no intervalo de 70,0 a 130,0 µg.mL-1 com coeficiente de correlação maior de 0,99. Os limites de detecção e de quantificação foram 6,2 µg.mL-1 e 20,6 µg.mL-1, respectivamente. A precisão do sistema foi inferior a 2,0%. A repetibilidade e precisão intermediária foram inferiores a 5,0%. A recuperação média foi de 102,1 %. No teste de especificidade, foram detectados três potenciais produtos de degradação com os seguintes tempos de retenção 1,3 2,0 e 2,2 min. O método por CLAE utilizou uma coluna Shim-pack CLC-ODS(M)® (250mm x4.6mm, 5µm). A fase móvel era constituída de acetonitrila:água (50:50) com 0,1% de ácido fórmico. O fluxo foi de 1.0 mL min-1 e detecção em 273 nm e temperatura a 30 ± 1 ºC. O método apresentou boa linearidade nas concentrações entre 7,0 e 13 µg.mL-1; com coeficiente de correlação maior de 0,99. E tempo de retenção para furosemida foi de 4,9 minutos. Os limites de detecção e de quantificação foram 0,6 µg.mL-1 e 1,9 µg.mL-1, respectivamente. A precisão do sistema foi inferior a 1,0%. A repetibilidade e precisão intermediária foram inferiores a 3,0%. A recuperação média foi de 105,1 %. No teste de especificidade, foram detectados três potenciais produtos de degradação com os seguintes tempos de retenção 2,4, 3,1 e 3,8 min. / Diuretics increase urine flow and sodium excretion and are used to adjust volume and / or composition of body fluids in a variety of clinical situations. Furosemide is a potent diuretic agent that induces a strong diuresis. It is used in the treatment of edema associated with heart and kidney disease. This research aimed to develop stability indicative methods for furosemide, by capillary electrophoresis in free solution (FSCE) and high-performance liquid chromatography (HPLC). The method FSCE used a fused silica capillary with a total length of 30.2 cm x 50.0 um di The buffer used was sodium tetraborate 2.0 mmol L-1 and 10% methanol, hydrodynamic injection 0.5 psi / 5s, +25 kV applied voltage, detection at 273 nm and 25 °C. The furosemide migration time was 1.8 minutes. The method achieved good linearity in the range of 70.0 to 130.0 µg.mL-1 with correlation coefficient higher of 0.99. The limits of detection and quantification were 6.2 and 20.6 µg.mL-1 µg.mL-1, respectively. The system accuracy was less than 2.0%. The repeatability and intermediate precision were less than 5.0%. The average recovery was 102.1%. The specificity test detected three potential degradation products with the following retention times 1.3, 2.0 and 2.2 min. The HPLC method used a Shim-pack CLC-ODS (M)® column (250mm x 4.6mm, 5µm). The mobile phase consisted of acetonitrile: water (50:50) with 0.1% formic acid. The flow rate was 1.0 mL min-1, detection at 273 nm and temperature at 30 ± 1°C. The method showed good linearity in concentrations between 7.0 and 13.0 µg.mL-1; with correlation coefficient higher of 0.99. Retention time for furosemide was 4.9 minutes. The limits of detection and quantification were 0.6 µg.mL-1 and 1.9 µg.mL-1, respectively. The system accuracy was less than 1.0%. The repeatability and intermediate precision were less than 3.0%. The average recovery was 105.1%. The specificity test detected three potential degradation products of the following retention times of 2.4, 3.1 and 3.8 min.
55

Desenvolvimento de um Medidor de Vazão Termal Inteligente. / Development of an Intelligent Thermal Flow Meter.

Marcos Antônio Andrade de Oliveira 07 July 2010 (has links)
Técnicas não-intrusivas de medição de vazão constituem uma necessidade crescente em diversas aplicações. Atualmente, diversos estudos têm sido realizados com o objetivo de desenvolver técnicas de medição não-intrusivas que possam suprir as deficiências das técnicas existentes. Este trabalho visa desenvolver um medidor de vazão baseado no princípio de convecção forçada (termal) não-intrusivo inteligente. O medidor utiliza dois transdutores RTD comerciais do tipo PT100, um aquecido, que é responsável pela medição da velocidade de escoamento, e o outro utilizado como referência de set-point de temperatura do sensor aquecido. Uma Rede Neural é responsável por corrigir os erros de medição do instrumento. Para a avaliação do medidor construído, foi desenvolvida uma bancada de realização de ensaios, possibilitando a variação da vazão e temperatura na seção de teste. Com o intuito de prover a bancada de uma referência para comparação, foi instalado também um medidor do tipo Venturi normalizado segundo a ABNT. / Non-intrusive techniques of flow measurement are very useful in several applications. Nowadays, several studies have been conducted to develop non-intrusive measuring techniques that can overcome the shortcomings of the existing ones. This work aims to design an intelligent non-intrusive flow meter device based on the forced heat convection principle (thermal). This device uses two commercial RTD transducers (PT100), one is used as reference of temperature set-point, and the other is responsible for the flow measurement. A neural network is responsible for correcting the errors in relation to the calibration standard. To evaluate the intelligent flow meter, test bench was built. In order to provide another flow meter to compare the results, an ABNT Venturi type flow meter was installed in the test bench.
56

Uso da torta de mamona não destoxificada na indução da muda forçada em poedeiras comerciais / Used non- destocified castor bean meal in inducion of forced changes in laying hens

Magalhães, Kelliani de Sousa January 2011 (has links)
MAGALHÃES. Kelliani de Sousa. Uso da torta de mamona não destoxificada na indução da muda forçada em poedeiras comerciais. 2011. 44 f. : Dissertação (mestrado) - Universidade Federal do Ceará, Centro de Ciências Agrárias, Departamento de Zootecnia, Fortaleza-CE, 2011 / Submitted by Nádja Goes (nmoraissoares@gmail.com) on 2016-08-02T15:24:33Z No. of bitstreams: 1 2009_dis_ksmmucida.pdf: 372555 bytes, checksum: b75840a3b3a55679fa42d1927f40fdb9 (MD5) / Approved for entry into archive by Nádja Goes (nmoraissoares@gmail.com) on 2016-08-02T15:24:47Z (GMT) No. of bitstreams: 1 2009_dis_ksmmucida.pdf: 372555 bytes, checksum: b75840a3b3a55679fa42d1927f40fdb9 (MD5) / Made available in DSpace on 2016-08-02T15:24:47Z (GMT). No. of bitstreams: 1 2009_dis_ksmmucida.pdf: 372555 bytes, checksum: b75840a3b3a55679fa42d1927f40fdb9 (MD5) Previous issue date: 2011 / This study aimed to evaluate the effects of changing diets containing different levels of non-detoxified castor bean meal (TM) in the induction of molt and compare them with the method of fasting. Used 120 Lohman LSL strain hens at 81 weeks of age were assigned to completely randomized design with four treatments and five replicates of six birds each. Treatments were the induction of molt by the method of fasting as a treatment, and others using diets change, being composed of approach ration containing castor bean at levels of 20, 30 and 40% (T2, T3 and T4 ). The method was applied to fast for 11 days and the other treatments, was established to suspend the declaration of change when the birds reached 23% loss of initial weight or up to 21 days supply. Blood samples were collected, one bird per replicate / treatment at the end of induction of changes were analyzed. Significant differences were observed between the methods of molt induction to the parameters measured during the induction of changes in performance of birds after molting. However, the quality of the eggs did not vary significantly among the evaluated methods. In general, the use of feed containing 40% of changes of TM enabled to obtain similar results in the production and egg quality to those obtained with the method of fasting, but with less alteration of blood parameters. The use of feed containing 20% or 30% of TM promoted in the period after the changes, performed significantly lower than other methods. The ration of changes made by laying diet containing not detoxified castor bean meal in the level of 40% proved to be a viable alternative to using the method of fasting. / A presente pesquisa teve como objetivo avaliar os efeitos do uso de rações de muda contendo diferentes níveis de torta de mamona não destoxificada (TM) na indução da muda forçada em poedeiras comerciais. Foram utilizadas 120 poedeiras da linhagem Lohman LSL, com 81 semanas de idade, distribuídas em delineamento inteiramente casualizado com quatro tratamentos e cinco repetições de seis aves cada. Os tratamentos consistiram na indução da muda forçada pelo método do jejum e, os demais, utilizando rações de muda, composta pela mistura de ração postura com torta de mamona nos níveis de 20, 30 e 40%. O método do jejum foi aplicado por 11 dias e, para os demais tratamentos, estabeleceu-se a suspensão da ração de muda quando as aves atingiram 23% de perda do peso inicial ou até 21 dias de alimentação. Diferenças significativas foram observadas entre os métodos de indução da muda forçada para os parâmetros medidos durante a indução da muda e no desempenho das aves após a muda. Entretanto, a qualidade dos ovos não variou significativamente entre os métodos avaliados. No geral, o uso de ração de muda contendo 40% de TM possibilitou a obtenção de resultados semelhante na produção e qualidade dos ovos aos obtidos com o método do jejum, mas com menor alteração dos parâmetros sanguíneos. O uso de ração contendo 20% ou 30% de TM promoveu, no período após a muda, desempenho significativamente menor que os demais métodos. O uso de ração de muda composta por ração de postura contendo torta de mamona não destoxificada no nível de 40% se mostrou uma alternativa viável ao uso do método do jejum.
57

Desenvolvimento de um Medidor de Vazão Termal Inteligente. / Development of an Intelligent Thermal Flow Meter.

Marcos Antônio Andrade de Oliveira 07 July 2010 (has links)
Técnicas não-intrusivas de medição de vazão constituem uma necessidade crescente em diversas aplicações. Atualmente, diversos estudos têm sido realizados com o objetivo de desenvolver técnicas de medição não-intrusivas que possam suprir as deficiências das técnicas existentes. Este trabalho visa desenvolver um medidor de vazão baseado no princípio de convecção forçada (termal) não-intrusivo inteligente. O medidor utiliza dois transdutores RTD comerciais do tipo PT100, um aquecido, que é responsável pela medição da velocidade de escoamento, e o outro utilizado como referência de set-point de temperatura do sensor aquecido. Uma Rede Neural é responsável por corrigir os erros de medição do instrumento. Para a avaliação do medidor construído, foi desenvolvida uma bancada de realização de ensaios, possibilitando a variação da vazão e temperatura na seção de teste. Com o intuito de prover a bancada de uma referência para comparação, foi instalado também um medidor do tipo Venturi normalizado segundo a ABNT. / Non-intrusive techniques of flow measurement are very useful in several applications. Nowadays, several studies have been conducted to develop non-intrusive measuring techniques that can overcome the shortcomings of the existing ones. This work aims to design an intelligent non-intrusive flow meter device based on the forced heat convection principle (thermal). This device uses two commercial RTD transducers (PT100), one is used as reference of temperature set-point, and the other is responsible for the flow measurement. A neural network is responsible for correcting the errors in relation to the calibration standard. To evaluate the intelligent flow meter, test bench was built. In order to provide another flow meter to compare the results, an ABNT Venturi type flow meter was installed in the test bench.
58

Análise experimental e numérica de convecção forçada em arranjo de obstáculos dentro de canal

Souza, Edilson Guimarães de [UNESP] 20 December 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-12-20Bitstream added on 2014-06-13T19:47:44Z : No. of bitstreams: 1 souza_eg_me_ilha.pdf: 959550 bytes, checksum: b4784dbcc883b1be2d0c6b7cce83f54b (MD5) / Fundação de Ensino Pesquisa e Extensão de Ilha Solteira (FEPISA) / O objetivo deste trabalho é a análise numérica e experimental de escoamento viscoso, incompressível, permanente, com transferência de calor, em um canal estreito contendo um arranjo de obstáculos retangulares. A análise experimental envolveu determinação de coeficiente de transferência de calor médio bem como o número de Nusselt médio e medidas de temperatura em esteira térmica para comparação com os resultados obtidos por simulação numérica. Para a análise numérica usamos o programa comercial de mecânica dos fluidos e transferência de calor computacional ICEPAK®. Verificamos que quanto mais adentro o obstáculo estiver no arranjo maior é a transferência de calor por convecção forçada. Determinamos coeficientes de transferência de calor médio e número de Nusselt médio (com incerteza entre 6 e 15%) e verificamos que o efeito da posição diminui à medida que a velocidade aumenta. Concluímos também que ambos os modelos de turbulência utilizados, k-ε padrão e k-ε RNG, foram incapazes de predizer o efeito da posição apropriadamente. Entretanto, o modelo k-ε RNG apresentou melhor comportamento, pois o seu uso resultou em soluções com valores de temperatura intermediários aos experimentais / The purpose of this work is the study of the numerical and experimental viscous incompressible steady flow with heat transfer into a narrow channel containing a rectangular array of obstacles. The experimental approach involves determining the coefficient of heat transfer and temperature measurements in thermal wake for comparison with the results obtained in numerical simulations. For the numerical analysis we use the commercial program of fluid mechanics and heat transfer computational ICEPAK™. We confirmed that in the last lines of the array the biggest is the heat transfer by forced convection. We determined the average heat transfer coefficients (with uncertainty between 6 and 15%) and found that the effect of the position decreases as flow speed increases. We use in the simulations the k-ε turbulence model and the k-ε RNG turbulence model. We conclude that both turbulence models used were unable to predict the effect of the position properly. However, the k-ε RNG model showed better behavior. The numerical temperatures with this model were consistent to the experimental temperature
59

Avaliação de métodos de muda forçada sobre o desempenho produtivo para codornas japonesas / Evaluation of methods of forced molt seedling on the productive acting for japanese quails

Mesquita Filho, Roque Machado de 07 March 2008 (has links)
Made available in DSpace on 2015-03-26T13:54:45Z (GMT). No. of bitstreams: 1 texto completo.pdf: 183039 bytes, checksum: b094ae15fafe623b510bd03b4d73b265 (MD5) Previous issue date: 2008-03-07 / Two experiments were driven in the Section of Aviculture of the Department of Zootecnia of the Universidade Federal de Viçosa - UFV, with the objective of determining the best method of forced seedling for Japanese and rising quail to determine the best fast period and his/her reflex about the parameters of productive acting and egg quality. In the experiment I 315 Japanese quails were used with 60 weeks of age. The phase changes forced it consisted of the supply of differentiated diets (treatments) during a period of 10 days and phase powderseedling consisted of 10 periods of 7 days each. The treatments were: T1 - ration of comfortable posture (it controls), T2 - ration fast for 2 days and 8 days of ration of it recreates, T3 - 5 days of posture ration with excess of Zn (10.000ppm) and 5 days with ration of it recreates, T4 - posture ration with deficiency in Na and T5 - supply during 5 days of corn maize flour and 5 days of ration of it recreates. Fast hídrico was not used. Delineamento was used casualizado entirely with 5 treatments, 7 repetitions and 9 birds for experimental unit. In the experiment II 168 Japanese quails were used with 62 weeks of age. The phase changes forced it consisted of the supply of differentiated diets (treatments) during a period of 10 days and phase powder- seedling consisted of 12 periods of 7 days each. The treatments were: T1 - posture ration the will (it controls), T2 - ration fast for 2 days and 8 days of ration of it recreates, T3 - ration fast for 3 days and 7 days of ration of it recreates. Fast hídrico was not used. Delineamento was used casualizado entirely with 3 treatments, 7 repetitions and 8 birds for experimental unit. The parameters analyzed for the two experiments were consumption of ration bird day (CRAD), production of eggs (POAD), marketable eggs (OC), weight of eggs (PO), egg mass (MO), alimentary conversion for egg mass (CAMO), alimentary conversion for dozen of egg (CADZO), gravity specifies (GE), viability (VIAB) and I weigh corporal (PI, PF, GP and PP). For the experiment I there was not significant difference (p>0,05) among the analyzed parameters CRAD, PO and GE. For POAD there was difference (P <0,05), and the birds of T2 obtained better acting, however the same treatment resulted in high mortality. For CADZO and CAMO there was significant difference (P <0,05), and the best values went to the treatment to control (T1) and the treatment with 2 days of fast and 8 days of ration of it recreates (T2). This way the forced seedling for quail doesn't result in improvement in the analyzed parameters. For the experiment II there was not significant effect (p>0,05) of the treatments for none of the appraised parameters. However, it was observed that in absolute values, POAD of the treatment controls (T1) it was superior to 10,45% in relation to the treatment fast of 2 days (T2) and superior to 4,44% to the treatment fast of 3 days (T3). Para VIAB the treatment controls (T1) it was inferior to 4,76% in relation to the treatment fast of 2 days (T2) and inferior to 1,86% to the treatment fast of 3 days (T3). this way it is not viable the practice of the alimentary fast for 2 or 3 days as technique of forced seedling for Japanese quail. / Foram conduzidos dois experimentos no Setor de Avicultura do Departamento de Zootecnia da Universidade Federal de Viçosa UFV, com o objetivando-se avaliar diferentes métodos de muda forçada para codorna japonesa sobre os parâmetros de desempenho produtivo e qualidade de ovo. No experimento I foram utilizadas 315 codornas japonesas com 60 semanas de idade. A fase muda forçada consistiu no fornecimento de dietas diferenciadas (tratamentos) durante um período de 10 dias e fase pós-muda consistiu em 10 períodos de 7 dias cada. Os tratamentos foram: T1 ração de postura à vontade (controle), T2 - jejum de ração por 2 dias seguidos de 8 dias de ração de recria à vontade, T3 - 5 dias de ração de postura à vontade com excesso de Zn (10.000ppm) seguidos de 5 dias com ração de recria à vontade, T4 - ração de postura à vontade com deficiência em Na e T5 - 5 dias de milho moído seguidos de 5 dias de ração de recria à vontade. Não foi utilizado jejum hídrico. Utilizou-se delineamento inteiramente casualizado com 5 tratamentos, 7 repetições e 9 aves por unidade experimental. No experimento II foram utilizadas 168 codornas japonesas com 62 semanas de idade. A fase de muda forçada consistiu no fornecimento de dietas diferenciadas (tratamentos) durante um período de 10 dias e fase pós-muda consistiu em 12 períodos de 7 dias cada. Os tratamentos foram: T1 ração de postura à vontade (controle), T2 - jejum de ração por 2 dias seguidos de 8 dias de ração de recria à vontade, T3 - jejum de ração por 3 dias seguidos de 7 dias de ração de recria à vontade. Não foi utilizado jejum hídrico. Utilizou-se delineamento inteiramente casualizado com 3 tratamentos, 7 repetições e 8 aves por unidade experimental. Os parâmetros analisados para os dois experimentos foram consumo de ração ave dia (CR), produção de ovos (POAD), ovos comercializáveis (OC), peso de ovos (PO), massa de ovo (MO), conversão alimentar por massa de ovo (CAMO), conversão alimentar por dúzia de ovo (CADZO), gravidade especifica (GE), viabilidade (VIAB) e peso corporal (PI, PF, GP e PP). Para o experimento I não houve diferença significativa (p>0,05) para os parâmetros analisados (CRAD, PO e GE). Para POAD houve diferença (P<0,05), sendo que as aves do tratamento com 2 dias de jejum e 8 dias de ração de recria (T2) obtiveram melhor desempenho, no entanto o mesmo tratamento resultou em elevada mortalidade. Para CADZO e CAMO houve diferença significativa (P<0,05), sendo que os melhores valores foram para o tratamento controle (T1) e o tratamento com 2 dias de jejum e 8 dias de ração de recria (T2). O método de jejum alimentar por 2 dias, seguidos de 8 dias de ração de recria à vontade, é o melhor para induzir muda forçada em codorna japonesa, porém, a muda forçada realizada por meio das técnicas testadas não foi capaz de promover melhora da produtividade das codornas japonesas no período pós muda. Para o experimento II não houve efeito significativo (p>0,05) dos tratamentos para nenhum dos parâmetros avaliados. No entanto, observouse que em valores absolutos, a POAD do tratamento controle (T1) foi superior a 10,45% em relação ao tratamento jejum de 2 dias (T2) e superior a 4,44% ao tratamento jejum de 3 dias (T3). Para VIAB o tratamento controle (T1) foi inferior a 4,76% em relação ao tratamento jejum de 2 dias (T2) e inferior a 1,86% ao tratamento jejum de 3 dias (T3). O método de jejum alimentar por 3 dias, seguidos de 7 dias de ração de recria à vontade, é o melhor para induzir muda forçada em codorna japonesa, porém, a muda forçada realizada por meio das técnicas testadas não foi capaz de promover melhora da produtividade das codornas japonesas no período pós muda.
60

Projeto industrial para aeração automática de leiras de compostagem orgânica / Industrial project for automated aeretion of organic composting piles

Figueira Júnior, Edson Alves 30 March 2012 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / Composting is a safety environmental alternative to reuse and treat organic wastes produced by human-beings. Although decomposition naturally happens, the handling of some factors, such as oxygen level, temperature, moisture content and pH, can alter the process speed, accelerating microbial activity. Aeration is a crucial practice during the composting process, since it can ensure adequate oxygen supply, temperature control and moisture content reduction in the windrows. Therefore, this work aimed to develop an automated process of compost pile aeration in order to accelerate and optimize the production of biofertilizers in an industrial plant. The trial was carried out at Valoriza Fertilizantes Company located in the city of Uberlândia - MG. Based on previous tests done in the company s standard ventilation system an automated system of forced aeration (SAFA) was projected. After installing this system, moisture content, oxygen level and temperature tests were performed aiming to verify the efficiency of the developed aeration system. / A compostagem é uma alternativa ambientalmente correta para o aproveitamento e tratamento dos resíduos orgânicos gerados pelo homem. Apesar de a decomposição ocorrer naturalmente, a manipulação de alguns fatores, como o nível de oxigênio, a temperatura, o teor de umidade e o pH, podem alterar a velocidade do processo, acelerando a atividade microbiana. A aeração é uma prática crucial durante o processo de compostagem, pois pode garantir suprimentos adequados de oxigênio, controlar a temperatura e reduzir o teor de umidade nas leiras. Objetivou-se neste trabalho desenvolver um processo automatizado de aeração de leiras de compostagem para acelerar e otimizar a produção de biofertilizantes em uma planta industrial. O experimento foi conduzido na Empresa Valoriza Agronegócios com sede na cidade de Uberlândia - MG. Baseado em testes realizados no sistema de ventilação padrão da empresa foi projetado um sistema de aeração forçada automatizado (SAFA). Após a instalação do sistema, testes de umidade, do teor de oxigênio e de temperatura foram realizados para verificar a eficiência do sistema de aeração desenvolvido. / Mestre em Engenharia Mecânica

Page generated in 0.1084 seconds